首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
This study aims to investigate the quality difference of short echo time (TE) breathhold 1H magnetic resonance spectroscopy (MRS) of the liver at 3.0T using the body and phased array coils, respectively. In total, 20 pairs of single-voxel proton spectra of the liver were acquired at 3.0T using the phased array and body coils as receivers. Consecutive stacks of breathhold spectra were acquired using the point resolved spectroscopy (PRESS) technique at a short TE of 30 ms and a repetition time (TR) of 1500 ms. The first spectroscopy sequence was “copied” for the second acquisition to ensure identical voxel positioning. The MRS prescan adjustments of shimming and water suppression, signal-to noise ratio (SNR), and major liver quantitative information were compared between paired spectra. Theoretical calculation of the SNR and homogeneity of the region of interest (ROI, 2 cm×2 cm×2 cm) using different coils loaded with 3D liver electromagnetic model of real human body was implemented in the theoretical analysis. The theoretical analysis showed that, inside the ROI, the SNR of the phase array coil was 2.8387 times larger than that of body coil and the homogeneity of the phase array coil and body coil was 80.10% and 93.86%, respectively. The experimental results showed excellent correlations between the paired data (all r > 0.86). Compared with the body coil group, the phased array group had slightly worse shimming effect and better SNR (all P values < .01). The discrepancy of the line width because of the different coils was approximately 0.8 Hz (0.00625 ppm). No significant differences of the major liver quantitative information of Cho/Lip2 height, Cho/Lip2 area, and lipid content were observed (all P values >0.05). The theoretical analysis and clinical experiment showed that the phased array coil was superior to the body coil with respect to 3.0T breathhold hepatic proton MRS.  相似文献   

3.
We herein describe a centrifugal microfluidic system to accomplish a fully automated serial dilution. The liquid flow on the disc was regulated by utilizing ferrowax microvalves systematically integrated into the channels within specially designed metering structures. By opening the differently positioned microvalves through irradiation of IR laser to allow metering, the same amount of diluent was serially eluted to the dilution chamber from the same diluent chamber. After dilution, the diluted samples were automatically delivered to the respective final product chambers by appropriately opening or closing the microvalves in the connecting channels, followed by rotating the disc. Based on this unique design principle, six consecutive two-fold and 10-fold dilutions were successfully achieved, yielding excellent accuracy in a wide dynamic range up to six orders of magnitude. Very importantly, the overall serial dilution process, including the diluent addition, mixing, and product transfer steps, was completed very rapidly within 5 min, due to the minimized procedures enabled by the automated actuation of the ferrowax microvalves at the rationally designed positions. We expect our centrifugal microfluidic system would serve as a powerful elemental tool to realize fully automated diagnostic microsystems involving the serial dilution process.  相似文献   

4.
A centrifugal compact disc (CD) microfluidic platform with reservoirs, micro-channels, and valves can be employed for implementing a complete immunoassay. Detection or biosensor chambers are either coated for immuno-interaction or a biosensor chip is inserted in them. On microfluidic CDs featuring such multi-step chemical/biological processes, the biosensor chamber must be repeatedly filled with fluids such as enzymes solutions, buffers, and washing solutions. After each filling step, the biosensor chamber needs to be evacuated by a passive siphoning process to prepare it for the next step in the assay. However, rotational speed dependency and limited space on a CD are two big obstacles to performing such repetitive filling and siphoning steps. In this work, a unique thermo-pneumatic (TP) Push-Pull pumping method is employed to provide a superior alternative biosensor chamber filling and evacuation technique. The proposed technique is demonstrated on two CD designs. The first design features a simple two-step microfluidic process to demonstrate the evacuation technique, while the second design shows the filling and evacuation technique with an example sequence for an actual immunoassay. In addition, the performance of the filling and evacuation technique as a washing step is also evaluated quantitatively and compared to the conventional manual bench top washing method. The two designs and the performance evaluation demonstrate that the technique is simple to implement, reliable, easy to control, and allows for repeated push-pulls and thus filling and emptying of the biosensor chamber. Furthermore, by addressing the issue of rotational speed dependency and limited space concerns in implementing repetitive filling and evacuation steps, this newly introduced technique increases the flexibility of the microfluidic CD platform to perform multi-step biological and chemical processes.  相似文献   

5.
A transducer format that replaces the electrode of an acoustic resonator with a planar spiral coil is used to extract multifrequency spectral information from adsorbed protein films. Both amorphous silica and crystalline piezoelectric resonators are driven to resonance by forces induced across an air gap by magnetic direct generation and piezoelectric excitation induced by the electromagnetic field of the coil. Inspection of the harmonic frequencies between 6 MHz and 0.6 GHz indicates that the response of these two resonator types is described by different families of shear acoustic standing waves, with similar acoustic features to the quartz crystal microbalance. Exposure of the devices to protein solutions results in reproducible shifts of their harmonic frequencies, up to a maximum of 15 kHz and increasing linearly with frequency and operating mode. The gradient, determined from the ratio of the frequency change to the operating frequency was determined as 21.5 x 10(-6) for the quartz device and 60.9 x 10(-6) for the silica device. Consistency with the Sauerbrey equation for the piezoelectric linear shear mode was comparable at a predicted value of 22.5 x 10(-6), but not for the radial shear mode of the silica device at 12.7 x 10(-6). Opportunities resulting from the wide bandwidth of the planar coil excitation and choice of acoustic mode are discussed with respect to acoustic fingerprinting of adsorbed proteins.  相似文献   

6.
This study evaluated the setup uncertainties for brain sites when using BrainLAB’s ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head. The radiotherapy was fractionated into 27–33 treatments. In total, 844 image verifications were performed for 28 patients and used for the analysis. The setup corrections along with the systematic and random errors were analyzed for six degrees of freedom in the translational (lateral, longitudinal, and vertical) and rotational (pitch, roll, and yaw) dimensions. Optimal PTV margins were calculated based on van Herk et al.’s [margin recipe = 2.5∑ + 0.7σ - 3 mm] and Stroom et al.’s [margin recipe = 2∑ + 0.7σ] formulas. The systematic errors (∑) were 0.72, 1.57, and 0.97 mm in the lateral, longitudinal, and vertical translational dimensions, respectively, and 0.72°, 0.87°, and 0.83° in the pitch, roll, and yaw rotational dimensions, respectively. The random errors (σ) were 0.31, 0.46, and 0.54 mm in the lateral, longitudinal, and vertical rotational dimensions, respectively, and 0.28°, 0.24°, and 0.31° in the pitch, roll, and yaw rotational dimensions, respectively. According to van Herk et al.’s and Stroom et al.’s recipes, the recommended lateral PTV margins were 0.97 and 1.66 mm, respectively; the longitudinal margins were 1.26 and 3.47 mm, respectively; and the vertical margins were 0.21 and 2.31 mm, respectively. Therefore, daily setup verifications using the BrainLAB ExacTrac 6D image guide system are very useful for evaluating the setup uncertainties and determining the setup margin.  相似文献   

7.
The simulation mathematical model of neuronal generator systems was used for analyzing the interaction between inputs from descending (afferent) systems and generators of scratching (locomotion). The data obtained indicate that in cases when generators of cyclic motor reactions influence the effectiveness of synaptic transmission from the fibers of descending (or afferent) systems, the differences in the main characteristics of signals that are produced by these generators themselves and those that come to them are emphasized. These data allow us to conclude that the system supplying interaction between inputs from suprasegmental (afferent) fiber systems and generators of locomotion of scratching can be interpreted as an adaptive filter which processes spatial and temporal information coming to the spinal cord via different suprasegmental or primary afferent inputs and allows generators of cyclic motor reactions to correct their functioning in accordance with changing external conditions.Neirofiziologiya/Neurophysiology, Vol. 25, No. 3, pp. 211–215, May–June, 1993.  相似文献   

8.
Central pattern generators are neuronal ensembles capable of producing the basic spatiotemporal patterns underlying ‘automatic’ movements (e.g. locomotion, respiration, swallowing and defense reactions), in the absence of peripheral feedback. Different experimental approaches, from classical electrophysiological and pharmacological methods to molecular and genetic ones, have been used to understand the cellular and synaptic bases of central pattern generator organization and reconfiguration of generator operation in behaviorally relevant contexts. Recently, it has been shown that the high reliability and flexibility of central pattern generators is determined by their redundant organization. Everything that is crucial for generator operation is determined by a number of complementary mechanisms acting in concert; however, various mechanisms are weighted differently in determining different aspects of central pattern generator operation.  相似文献   

9.
Understanding the dynamics of magnetic particles can help to advance several biomedical nanotechnologies. Previously, scaling relationships have been used in magnetic spectroscopy of nanoparticle Brownian motion (MSB) to measure biologically relevant properties (e.g., temperature, viscosity, bound state) surrounding nanoparticles in vivo. Those scaling relationships can be generalized with the introduction of a master variable found from non-dimensionalizing the dynamical Langevin equation. The variable encapsulates the dynamical variables of the surroundings and additionally includes the particles’ size distribution and moment and the applied field’s amplitude and frequency. From an applied perspective, the master variable allows tuning to an optimal MSB biosensing sensitivity range by manipulating both frequency and field amplitude. Calculation of magnetization harmonics in an oscillating applied field is also possible with an approximate closed-form solution in terms of the master variable and a single free parameter.  相似文献   

10.
Possible organization patterns of scratching and locomotor generators that allow interpretation of experimentally demonstrated reorganizations in temporal parameters of these generator activities after electrical stimulation of descending and peripheral afferent systems were analyzed with application of mathematical simulation of neuronal generator systems. The results obtained led to the conclusion that patterns of such reorganizations influenced by signals from suprasegmental and/or peripheral systems may be determined by only two factors: 1) the structure of synaptic connections between interneuronal functional groups underlying these generator associations, and 2) the structure of connections between these groups of interneurons and fibers from suprasegmental and peripheral afferent sources. The existence of inhibitory-excitatory actions from descending and afferent systems upon the neurons of locomotor or scratching generator half-centers is a sufficient condition to ensure phasic changes in the sensitivity of these generators to supraspinal and afferent signals. The locomotor generator, unlike the scratching generator, is apparently characterized by a more complex organization of connections between functional neuronal groupings and descending fibers.Translated from Neirofiziologiya, Vol. 25, No. 1, pp. 45–50, January–February, 1993.  相似文献   

11.
Changes in the parameters of activity in hindlimb locomotor generators following decerebellation were quantified during experiments on decerebrate immobilized cats. Eliminating modulating cerebellar influences on nuclei of descending systems was found to lead to a slight increase in the length of activity in the flexor generator half-center and less intensive activity, as well as shortening of the period and more intensive activity in the extensor half-center, together with increased instability in generator operation, reduced statistical dependence between alterations in parameters of activity at the hindlimb half-center generators, and finally intensified effects of afferent inputs on generator activity. A comparison is drawn between the functional role of the spino-cerebellar loop in the operation of locomotor and scratch generators.A. A. Bogomolets Institute of Physiology, Academy of Sciences of the Ukrainian SSR, Kiev. Translated from Neirofiziologiya, Vol. 23, No. 2, pp. 142–150, March–April, 1991.  相似文献   

12.
When exploring immersed surfaces the cypris larvae of barnacles employ a tenacious and rapidly reversible adhesion mechanism to facilitate their characteristic ‘walking’ behaviour. Although of direct relevance to the fields of marine biofouling and bio-inspired adhesive development, the mechanism of temporary adhesion in cyprids remains poorly understood. Cyprids secrete deposits of a proteinaceous substance during surface attachment and these are often visible as ‘footprints’ on previously explored surfaces. The attachment structures, the antennular discs, of cyprids also present a complex morphology reminiscent of both the hairy appendages used by some terrestrial invertebrates for temporary adhesion and a classic ‘suction cup’. Despite the numerous analytical approaches so-far employed, it has not been possible to resolve conclusively the respective contributions of viscoelastic adhesion via the proteinaceous ‘temporary adhesive’, ‘dry’ adhesion via the cuticular villi present on the disc and the behavioural contribution by the organism. In this study, high-speed photography was used for the first time to capture the behaviour of cyprids at the instant of temporary attachment and detachment. Attachment is facilitated by a constantly sticky disc surface – presumably due to the presence of the proteinaceous temporary adhesive. The tenacity of the resulting bond, however, is mediated behaviourally. For weak attachment the disc is constantly moved on the surface, whereas for a strong attachment the disc is spread out on the surface. Voluntary detachment is by force, requiring twisting or peeling of the bond – seemingly without any more subtle detachment behaviours. Micro-bubbles were observed at the adhesive interface as the cyprid detached, possibly an adaptation for energy dissipation. These observations will allow future work to focus more specifically on the cyprid temporary adhesive proteins, which appear to be fundamental to adhesion, inherently sticky and exquisitely adapted for reversible adhesion underwater.  相似文献   

13.
An investigation was made of the properties of bird feathers as piezoelectric transducers in the audiofrequency range and as dielectric receptors of electromagnetic radiation in the microwave region. In the first case, cartridges of the ceramic and magnetic type and an electromagnetic transducer probe were used as detecting devices. Results show piezoelectric resonances in the 1 to 20-kHz region for the calami of feathers.  相似文献   

14.
The mechanism of injury to the back should be obtained with the utmost accuracy and set down in the history as a separate paragraph under that heading. This is usually best obtained by questioning and requestioning the patient during the course of the examination. A history of any previous back affections should also be obtained at the first visit.The detailed examination of the back is not complete without a general physical examination.X-ray studies should be done immediately in all cases in which the injury has been caused by direct violence or forceful indirect violence (as in “jackknife” injury).Terms such as “disc disease,” “ruptured intervertebral disc” and various others that convey a similar meaning should not be used as the initial diagnosis and should be withheld until such a diagnosis is definitely established.The plan of treatment may include a period in hospital or of rest at home, or it may be carried out with the patient ambulatory. Corsets and braces should be prescribed only when they are to serve a definite function and the same can be said of physiotherapy.  相似文献   

15.
This paper presents an investigation of novel contact‐mode hybrid nanogenerators comprising cascaded piezoelectric and triboelectric units. For the first time, a theoretical analysis of the contact‐mode hybrid generator is presented to describe the relationships among transfer charges, voltage, current, and average output power in terms of material properties, hybrid generator structural parameters, harvesting, and operational conditions. New hybrid generators with much enhanced piezoelectricity are fabricated via a simple, room‐temperature, cost‐effective route by using nonwoven fabrics made from electrospun Polyvinyledenedifluoride‐trifluoroethylene (PVDF‐TrFE)/Ag nanowire nanofibers and Polydimethylsiloxane (PDMS) composites with graphite nanoparticles. The results provide a powerful tool for synthesis and selection of materials, design and optimization of the configuration, and operation of such kind of hybrid generators as well as determination of the value of external capacitor.  相似文献   

16.
Degtyarenko  A. M. 《Neurophysiology》1988,20(5):423-432
Different organizational arrangements of scratching and locomotor rhythm generators were simulated by a computer-aided mathematical model. A functional group of neurons (a hemicenter constructed on the basis of a stochastically arranged neuronal network) served as the basis for the generator. Several organizational arrangements of scratching and locomotor rhythm generators are considered: two hemicenters with reciprocal inhibitory connections and tonic excitatory influences on both; two hemicenters with inhibitory-excitatory connections and tonic excitatory influences on only one of these; circular structures consisting of more than two functional groups of neurons with excitatory and inhibitory connections between them. All these arrangements would allow for generation of rhythmic activity with a similar time course to that of scratching and locomotor rhythm. It was found that the transition from locomotor to scratching rhythm could be based on fairly simply organized effects on generator neurons. Principles possibly guiding the construction of spinal generators of scratching and locomotor movements are discussed.A. A. Bogomolets Institute of Physiology, Academy of Sciences of the Ukrainian SSR, Kiev. Translated from Neirofiziologiya, Vol. 20, No. 5, pp. 586–597, September–October, 1988.  相似文献   

17.
Rearrangement of the parameters of scratch and locomotor generators produced by electrical stimulation of the inferior olive and nucleus reticularis lateralis as well as the cerebellar fastigial nucleus and nucleus interpositus was investigated in decerebrate immobilized cats. Results showed that a comparable rearrangement of the time course of activity in both locomotor and scratch generators was produced by altering the nature of signals proceeding along mossy and climbing fibers alike. Maximum rearrangement of scratch and locomotor generator activity, as induced by electrical activation of the inferior olive and lateral reticular nucleus, is observed during the first half of flexor half-center operation in these generators. The scratch (unlike the locomotor) generator typically shows considerably rearranged efferent activity following electrical activation of nuclei of the cerebellum and cerebellar afferents. The article discusses mechanisms of cerebellar origin which may be responsible for exerting a corrective action on scratch and locomotor generators during change in the phase and amplitude parameters of cerebellar input signals.A. A. Bogomolets Institute of Physiology, Ukrainian Academy of Sciences, Kiev. Translated from Neirofiziologiya, Vol. 24, No. 2, pp. 131–140, March–April, 1992.  相似文献   

18.

Introduction

Neuroimaging of macaques at ultra-high field (UHF) is usually conducted by combining a volume coil for transmit (Tx) and a phased array coil for receive (Rx) tightly enclosing the monkey’s head. Good results have been achieved using vertical or horizontal magnets with implanted or near-surface coils. An alternative and less costly approach, the travelling-wave (TW) excitation concept, may offer more flexible experimental setups on human whole-body UHF magnetic resonance imaging (MRI) systems, which are now more widely available. Goal of the study was developing and validating the TW concept for in vivo primate MRI.

Methods

The TW Primate System (TWPS) uses the radio frequency shield of the gradient system of a human whole-body 7 T MRI system as a waveguide to propagate a circularly polarized B1 field represented by the TE11 mode. This mode is excited by a specifically designed 2-port patch antenna. For receive, a customized neuroimaging monkey head receive-only coil was designed. Field simulation was used for development and evaluation. Signal-to-noise ratio (SNR) was compared with data acquired with a conventional monkey volume head coil consisting of a homogeneous transmit coil and a 12-element receive coil.

Results

The TWPS offered good image homogeneity in the volume-of-interest Turbo spin echo images exhibited a high contrast, allowing a clear depiction of the cerebral anatomy. As a prerequisite for functional MRI, whole brain ultrafast echo planar images were successfully acquired.

Conclusion

The TWPS presents a promising new approach to fMRI of macaques for research groups with access to a horizontal UHF MRI system.  相似文献   

19.
Here, we demonstrate a simple method for the rapid production of size-controllable, monodisperse, W/O microdroplets using a capillary-based centrifugal microfluidic device. W/O microdroplets have recently been used in powerful methods that enable miniaturized chemical experiments. Therefore, developing a versatile method to yield monodisperse W/O microdroplets is needed. We have developed a method for generating monodisperse W/O microdroplets based on a capillary-based centrifugal axisymmetric co-flowing microfluidic device. We succeeded in controlling the size of microdroplets by adjusting the capillary orifice. Our method requires equipment that is easier-to-use than with other microfluidic techniques, requires only a small volume (0.1-1 µl) of sample solution for encapsulation, and enables the production of hundreds of thousands number of W/O microdroplets per second. We expect this method will assist biological studies that require precious biological samples by conserving the volume of the samples for rapid quantitative analysis biochemical and biological studies.  相似文献   

20.
CD-ELISA uses the microfluidic ranking method and centrifugal force to control the testing solution as it flows into the reaction region. The most challenging part of CD-ELISA is controlling the flow process for different biological testing solutions, i.e. the controlling sequence for the microfluidic channel valves. The microfluidic channel valve is therefore the most important fluid channel structure for CD-ELISA. In this study, we propose a valve design suitable for a wide range rotational speeds which can be applied for mass production (molding). Together with supporting experiments, simulation based on two-phase flow theory is used in this study, and the feasibility of this novel valve design is confirmed. Influencing design factors for the microfluidic channel valves in CD-ELISA are investigated, including various shapes of the arc, distance d, radius r, the location of the center of the circle, and the contact angle. From both the experimental results and the simulated results, it is evident that the narrowest channel width and the contact angle are the primary factors influencing valve burst frequency. These can be used as the main controlling factors during the design.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号