首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Although several studies have evaluated the relationship between bisphenol A (BPA) and thyroid functions, their results are not entirely consistent. Little is known about BPA in relation to thyroid volume and structure.

Methods

We examined the association of BPA with thyroid volume and thyroid nodules using data from 718 Chinese children living in the East Coast of China in 2012. First morning urine samples were collected for the determination of urinary BPA, creatinine, and urinary iodine concentrations (UIC). Thyroid volume (TV) and nodules were assessed by thyroid ultrasonography.

Results

The median of TV was 3.14ml. 459(63.9%) children took iodized salt at home and the median of UIC was 159μg/l. BPA was detected in 99.9% of the urine samples and the medians for boys and girls were 2.64 and 2.35μg/g creatinine, respectively. Of all participants 14.0% had thyroid nodules. Urinary BPA concentration was inversely associated with thyroid volume (β = -0.033, 95% CI: -0.053, -0.013) and the risk for multiple nodules (OR = 0.78; 95% CI: 0.63, 0.97). The associations above were similar for children who consumed iodized salt and those consumed non-iodized salt.

Conclusions

The data suggest that BPA may be one of the influencing factors for TV and thyroid nodules and its effects are independent of iodine nutrition status in children.  相似文献   

2.

Background

Sensitive and specific detection of malarial parasites is crucial in controlling the significant malaria burden in the developing world. Also important is being able to identify life threatening Plasmodium falciparum malaria quickly and accurately to reduce malaria related mortality. Existing methods such as microscopy and rapid diagnostic tests (RDTs) have major shortcomings. Here, we describe a new real-time PCR-based diagnostic test device at point-of-care service for resource-limited settings.

Methods

Truenat® Malaria, a chip-based microPCR test, was developed by bigtec Labs, Bangalore, India, for differential identification of Plasmodium falciparum and Plasmodium vivax parasites. The Truenat Malaria tests runs on bigtec’s Truelab Uno® microPCR device, a handheld, battery operated, and easy-to-use real-time microPCR device. The performance of Truenat® Malaria was evaluated versus the WHO nested PCR protocol. The Truenat® Malaria was further evaluated in a triple-blinded study design using a sample panel of 281 specimens created from the clinical samples characterized by expert microscopy and a rapid diagnostic test kit by the National Institute of Malaria Research (NIMR). A comparative evaluation was done on the Truelab Uno® and a commercial real-time PCR system.

Results

The limit of detection of the Truenat Malaria assay was found to be <5 parasites/μl for both P. falciparum and P. vivax. The Truenat® Malaria test was found to have sensitivity and specificity of 100% each, compared to the WHO nested PCR protocol based on the evaluation of 100 samples. The sensitivity using expert microscopy as the reference standard was determined to be around 99.3% (95% CI: 95.5–99.9) at the species level. Mixed infections were identified more accurately by Truenat Malaria (32 samples identified as mixed) versus expert microscopy and RDTs which detected 4 and 5 mixed samples, respectively.

Conclusion

The Truenat® Malaria microPCR test is a valuable diagnostic tool and implementation should be considered not only for malaria diagnosis but also for active surveillance and epidemiological intervention.  相似文献   

3.

Background

Bispecific T cell engager (BiTE®) are single-chain bispecific antibody constructs with dual specificity for CD3 on T cells and a surface antigen on target cells. They can elicit a polyclonal cytotoxic T cell response that is not restricted by T cell receptor (TCR) specificity, and surface expression of MHC class I/peptide antigen complexes. Using human EpCAM/CD3-bispecific BiTE® antibody construct AMG 110, we here assessed to what extent surface expression of PD-L1, cytoplasmic expression of indoleamine-2,3-deoxygenase type 1, Bcl-2 and serpin PI-9, and the presence of transforming growth factor beta (TGF-β), interleukin-10 (IL-10) and adenosine in culture medium can impact redirected lysis by AMG 110-engaged T cells.

Methods

The seven factors, which are all involved in inhibiting T cell functions by cancer cells, were tested with human EpCAM-expressing Chinese hamster ovary (CHO) target cells at levels that in most cases exceeded those observed in a number of human cancer cell lines. Co-culture experiments were used to determine the impact of the evasion mechanisms on EC50 values and amplitude of redirected lysis by AMG 110, and on BiTE®-induced proliferation of previously resting human peripheral T cells.

Findings

An inhibitory effect on redirected lysis by AMG 110-engaged T cells was seen upon overexpression of serpin PI-9, Bcl-2, TGF-βand PD-L1. An inhibitory effect on induction of T cell proliferation was only seen with CHO cells overexpressing IDO. In no case, a single evasion mechanism rendered target cells completely resistant to BiTE®-induced lysis, and even various combinations could not.

Conclusions

Our data suggest that diverse mechanisms employed by cancer cells to fend off T cells cannot inactivate AMG 110-engaged T cells, and that inhibitory effects observed in vitro may be overcome by increased concentrations of the BiTE® antibody construct.  相似文献   

4.

Background

After the implementation of the universal salt iodization (USI) program in 1996, seven cross-sectional school-based surveys have been conducted to monitor iodine deficiency disorders (IDD) among children in eastern China.

Objectives

This study aimed to examine the correlation of total goiter rate (TGR) with average thyroid volume (Tvol) and urinary iodine concentration (UIC) in Jiangsu province after IDD elimination.

Design

Probability-proportional-to-size sampling was applied to select 1,200 children aged 8–10 years old in 30 clusters for each survey in 1995, 1997, 1999, 2001, 2002, 2005, 2009 and 2011. We measured Tvol using ultrasonography in 8,314 children and measured UIC (4,767 subjects) and salt iodine (10,184 samples) using methods recommended by the World Health Organization. Tvol was used to calculate TGR based on the reference criteria specified for sex and body surface area (BSA).

Results

TGR decreased from 55.2% in 1997 to 1.0% in 2009, and geometric means of Tvol decreased from 3.63 mL to 1.33 mL, along with the UIC increasing from 83 μg/L in 1995 to 407 μg/L in 1999, then decreasing to 243 μg/L in 2005, and then increasing to 345 μg/L in 2011. In the low goiter population (TGR < 3.9%), TGR was positively associated with average Tvol (r = 0.99); UIC showed a non-linear association with average Tvol, and UIC > 300 μg/L was associated with a smaller average Tvol in children.

Conclusions

After IDD elimination in Jiangsu province in 2001, lower TGR was associated with smaller average Tvol. Average Tvol was more sensitive than TGR in detecting the fluctuation of UIC. A UIC of 300 μg/L may be defined as a critical value for population level iodine status monitoring.  相似文献   

5.

Background

Human papillomavirus (HPV) vaccines confer protection against the oncogenic genotypes HPV16 and HPV18 through the generation of type-specific neutralizing antibodies raised against virus-like particles (VLP) representing these genotypes. The vaccines also confer a degree of cross-protection against HPV31 and HPV45, which are genetically-related to the vaccine types HPV16 and HPV18, respectively, although the mechanism is less certain. There are a number of humoral immune measures that have been examined in relation to the HPV vaccines, including VLP binding, pseudovirus neutralization and the enumeration of memory B cells. While the specificity of responses generated against the vaccine genotypes are fairly well studied, the relationship between these measures in relation to non-vaccine genotypes is less certain.

Methods

We carried out a comparative study of these immune measures against vaccine and non-vaccine genotypes using samples collected from 12–15 year old girls following immunization with three doses of either Cervarix® or Gardasil® HPV vaccine.

Results

The relationship between neutralizing and binding antibody titers and HPV-specific memory B cell levels for the vaccine genotypes, HPV16 and HPV18, were very good. The proportion of responders approached 100% for both vaccines while the magnitude of these responses induced by Cervarix® were generally higher than those following Gardasil® immunization. A similar pattern was found for the non-vaccine genotype HPV31, albeit at a lower magnitude compared to its genetically-related vaccine genotype, HPV16. However, both the enumeration of memory B cells and VLP binding responses against HPV45 were poorly related to its neutralizing antibody responses. Purified IgG derived from memory B cells demonstrated specificities similar to those found in the serum, including the capacity to neutralize HPV pseudoviruses.

Conclusions

These data suggest that pseudovirus neutralization should be used as the preferred humoral immune measure for studying HPV vaccine responses, particularly for non-vaccine genotypes.  相似文献   

6.

Background

In spite of the salt iodization, iodine deficiency disorders (IDD) have not been sustainably eliminated in China. There are coastal areas with low iodized salt coverage rates (iodine nutrition is inadequate) and other areas with excessive amounts of iodine in the drinking water.

Objective

This study aimed to clarify the association of iodine deficiencies resulting from a low coverage rate of iodized salt, excess iodine intake from drinking water with thyroid function and disease in adults.

Design

A cross-sectional study was conducted in adults in different iodine nutrition areas in three provinces in China.

Results

The prevalence of thyroid nodules was 15.52%, 8.66% and 22.17% in the iodine excess, sufficient and deficient groups, respectively. The prevalence of subclinical hypothyroidism was 20.09%, 10.41%, and 2.25% in the excess, sufficient and deficient iodine groups, respectively. The prevalence of subclinical hyperthyroidism and overt hyperthyroidism in the iodine deficient group was higher than that in the iodine excess group ( = 9.302, p = 0.002) and iodine sufficient group ( = 7.553, p = 0.006). Thyroid-stimulating hormone (TSH) was significantly correlated with excess iodine intake (β = 1.764,P = 0.001) and deficient iodine intake (β = −1.219, P = 0.028).

Conclusions

Thyroid nodules are more likely to be present in the iodine excess and deficient areas than in the iodine sufficient areas. Subclinical hyperthyroidism and overt hyperthyroidism are more likely to be prevalent in the iodine deficient areas than in the iodine excess or sufficient areas. Subclinical hypothyroidism is more likely to be prevalent in the high iodine intake areas than in the iodine deficient or sufficient areas. Median TSH may be deemed as an alternative indicator for monitoring the iodine nutrition status of the adult population in iodine excess and deficient areas.  相似文献   

7.

Background

Papillomavirus disease and associated cancers remain a significant health burden in much of the world. The current protective vaccines, Gardasil and Cervarix, are expensive and not readily available to the underprivileged. In addition, the vaccines have not gained wide acceptance in the United States nor do they provide therapeutic value. Papillomaviruses are strictly species specific and thus human viruses cannot be studied in an animal host. An appropriate model for mucosal disease has long been sought. We chose to investigate whether the newly discovered mouse papillomavirus, MmuPV1, could infect mucosal tissues in Foxn1nu/Foxn1nu mice.

Methods

The vaginal and anal canals of Foxn1nu/Foxn1nu mice were gently abraded using Nonoxynol-9 and “Doctor’s BrushPicks” and MmuPV1 was delivered into the vaginal tract or the anal canal.

Results

Productive vaginal, cervical and anal infections developed in all mice. Vaginal/cervical infections could be monitored by vaginal lavage. Dysplasias were evident in all animals.

Conclusions

Anogenital tissues of a common laboratory mouse can be infected with a papillomavirus unique to that animal. This observation will pave the way for fundamental virological and immunological studies that have been challenging to carry out heretofore due to lack of a suitable model system.  相似文献   

8.

Importance

Surgical site infections remain one of the most frequent complications following abdominal surgery and cause substantial costs, morbidity and mortality.

Objective

To assess the effectiveness of wound edge protectors in open abdominal surgery in reducing surgical site infections.

Evidence Review

A systematic literature search was conducted according to a prespecified review protocol in a variety of data-bases combined with hand-searches for randomized controlled trials on wound edge protectors in patients undergoing laparotomy. A qualitative and quantitative analysis of included trials was conducted.

Findings

We identified 16 randomized controlled trials including 3695 patients investigating wound edge protectors published between 1972 and 2014. Critical appraisal uncovered a number of methodological flaws, predominantly in the older trials. Wound edge protectors significantly reduced the rate of surgical site infections (risk ratio 0.65; 95%CI, 0.51–0.83; p = 0.0007; I2 = 52%). The results were robust in a number of sensitivity analyses. A similar effect size was found in the subgroup of patients undergoing colorectal surgery (risk ratio 0.65; 95%CI, 0.44–0.97; p = 0.04; I2 = 56%). Of the two common types of wound protectors double ring devices were found to exhibit a greater protective effect (risk ratio 0.29; 95%CI, 0.15–0.55) than single-ring devices (risk ratio 0.71; 95%CI, 0.54–0.92), but this might largely be due to the lower quality of available data for double-ring devices. Exploratory subgroup analyses for the degree of contamination showed a larger protective effect in contaminated cases (0.44; 95%CI, 0.28–0.67; p = 0.0002, I2 = 23%) than in clean-contaminated surgeries (0.72, 95%CI, 0.57–0.91; p = 0.005; I2 = 46%) and a strong effect on the reduction of superficial surgical site infections (risk ratio 0.45; 95%CI, 0.24–0.82; p = 0.001; I2 = 72%).

Conclusions and Relevance

Wound edge protectors significantly reduce the rate of surgical site infections in open abdominal surgery. Further trials are needed to explore their effectiveness in different risk constellations.  相似文献   

9.

Objective

We evaluated postoperative changes in nasal cavity volume and their effects on nasal function and symptoms after endoscopic endonasal transsphenoidal approach for antero-central skull base surgery.

Study Design

Retrospective chart review at a tertiary referral center.

Methods

We studied 92 patients who underwent binostril, four-hand, endoscopic endonasal transsphenoidal approach surgery using the bilateral modified nasoseptal rescue flap technique. Pre- and postoperative paranasal computed tomography and the Mimics® program were used to assess nasal cavity volume changes at three sections. We also performed several pre- and postoperative tests, including the Connecticut Chemosensory Clinical Research Center test, Cross-Cultural Smell Identification Test, Nasal Obstruction Symptoms Evaluation, and Sino-Nasal Outcome Test-20. In addition, a visual analog scale was used to record subjective symptoms. We compared these data with the pre- and postoperative nasal cavity volumes.

Results

Three-dimensional, objective increases in nasal passage volumes were evident between the inferior and middle turbinates (p<0.001) and between the superior turbinate and choana (p = 0.006) postoperatively. However, these did not correlate with subjectively assessed symptoms (NOSE, SNOT-20 and VAS; all nasal cavity areas; p≥0.05) or olfactory dysfunction (CCCRC and CCSIT test; all nasal cavity areas; p≥0.05).

Conclusion

Skull base tumor surgery via an endoscopic endonasal transsphenoidal approach altered the patients’ nasal anatomy, but the changes in nasal cavity volumes did not affect nasal function or symptoms. These results will help surgeons to appropriately expose the surgical field during an endoscopic endonasal transsphenoidal approach.  相似文献   

10.

Introduction

There is evidence that greater neighbourhood walkability (i.e., neighbourhoods with more amenities and well-connected streets) is associated with higher levels of total walking in Europe and in Asia, but it remains unclear if this association holds in the Canadian context and in chronic disease populations. We examined the relationships of different walkability measures to biosensor-assessed total walking (i.e., steps/day) in adults with type 2 diabetes living in Montreal (QC, Canada).

Materials and Methods

Participants (60.5±10.4 years; 48.1% women) were recruited through McGill University-affiliated clinics (June 2006 to May 2008). Steps/day were assessed once per season for one year with pedometers. Neighbourhood walkability was evaluated through participant reports, in-field audits, Geographic Information Systems (GIS)-derived measures, and the Walk Score®. Relationships between walkability and daily steps were estimated using Bayesian longitudinal hierarchical linear regression models (n = 131).

Results

Participants who reported living in the most compared to the least walkable neighbourhoods completed 1345 more steps/day (95% Credible Interval: 718, 1976; Quartiles 4 versus 1). Those living in the most compared to the least walkable neighbourhoods (based on GIS-derived walkability) completed 606 more steps per day (95% CrI: 8, 1203). No statistically significant associations with steps were observed for audit-assessed walkability or the Walk Score®.

Conclusions

Adults with type 2 diabetes who perceived their neighbourhoods as more walkable accumulated more daily steps. This suggests that knowledge of local neighborhood features that enhance walking is a meaningful predictor of higher levels of walking and an important component of neighbourhood walkability.  相似文献   

11.

Background

Failure to recognize acute deterioration in hospitalized patients may contribute to cardiopulmonary arrest, unscheduled intensive care unit admission and increased mortality.

Purpose

In this systematic review we aimed to determine whether continuous non-invasive respiratory monitoring improves early diagnosis of patient deterioration and reduces critical incidents on hospital wards.

Data Sources

Studies were retrieved from Medline, Embase, CINAHL, and the Cochrane library, searched from 1970 till October 25, 2014.

Study Selection

Electronic databases were searched using keywords and corresponding synonyms ‘ward’, ‘continuous’, ‘monitoring’ and ‘respiration’. Pediatric, fetal and animal studies were excluded.

Data Extraction

Since no validated tool is currently available for diagnostic or intervention studies with continuous monitoring, methodological quality was assessed with a modified tool based on modified STARD, CONSORT, and TREND statements.

Data Synthesis

Six intervention and five diagnostic studies were included, evaluating the use of eight different devices for continuous respiratory monitoring. Quantitative data synthesis was not possible because intervention, study design and outcomes differed considerably between studies. Outcomes estimates for the intervention studies ranged from RR 0.14 (0.03, 0.64) for cardiopulmonary resuscitation to RR 1.00 (0.41, 2.35) for unplanned ICU admission after introduction of continuous respiratory monitoring,

Limitations

The methodological quality of most studies was moderate, e.g. ‘before-after’ designs, incomplete reporting of primary outcomes, and incomplete clinical implementation of the monitoring system.

Conclusions

Based on the findings of this systematic review, implementation of routine continuous non-invasive respiratory monitoring on general hospital wards cannot yet be advocated as results are inconclusive, and methodological quality of the studies needs improvement. Future research in this area should focus on technology explicitly suitable for low care settings and tailored alarm and treatment algorithms.  相似文献   

12.

Background

Tuberculosis (TB) remains a significant health problem in the Canadian Arctic. Substantial health system delays in TB diagnosis can occur, in part due to the lack of capacity for onsite microbiologic testing. A study recently evaluated the yield and impact of a rapid automated PCR test (Xpert®MTB/RIF) for the diagnosis of TB in Iqaluit (Nunavut). We conducted an economic analysis to evaluate the expected cost relative to the expected reduction in time to treatment initiation, with the addition of Xpert®MTB/RIF to the current diagnostic and treatment algorithms used in this setting.

Methods

A decision analysis model compared current microbiologic testing to a scenario where Xpert®MTB/RIF was added to the current diagnostic algorithm for active TB, and incorporated costs and clinical endpoints from the Iqaluit study. Several sensitivity analyses that considered alternative use were also considered. We estimated days to TB diagnosis and treatment initiation, health system costs, and the incremental cost per treatment day gained for each individual evaluated for possible TB.

Results

With the addition of Xpert®MTB/RIF, costs increased while days to TB treatment initiation were reduced. The incremental cost per treatment day gained (per individual investigated for TB) was $164 (95% uncertainty range $85, $452). In a sensitivity analysis that considered hospital discharge after a single negative Xpert®MTB/RIF, the Xpert®MTB/RIF scenario was cost saving.

Interpretation

Adding Xpert®MTB/RIF to the current diagnostic algorithm for TB in Nunavut appears to reduce time to diagnosis and treatment at reasonable cost. It may be especially well suited to overcome some of the other logistical barriers that are unique to this and other remote communities.  相似文献   

13.

Introduction

Intraosseous infusion is recommended if peripheral venous access fails for cardiopulmonary resuscitation or other medical emergencies. The aim of this study, using body donors, was to compare a semi-automatic (EZ-IO®) device at two insertion sites and a sternal intraosseous infusion device (FASTR).

Methods

Twenty-seven medical students being inexperienced first-time users were randomized into three groups using EZ-IO and FASTR. The following data were evaluated: attempts required for successful placement, insertion time and flow rates with and without external pressure to the infusion.

Results

The first-pass insertion success of the EZ-IO tibia, EZ-IO humerus and FASTR was 91%, 77%, and 95%, respectively. Insertion times (MW±SD) did not show significant differences with 17±7 (EZ-IO tibia) vs. 29±42 (EZ-IO humerus) vs. 33±21 (FASTR), respectively. One-minute flow rates using external pressures between 0 mmHg and 300 mmHg ranged between 27±5 to 69±54 ml/min (EZ-IO tibia), 16±3 to 60±44 ml/min (EZ-IO humerus) and 53±2 to 112±47 ml/min (FASTR), respectively. Concerning pressure-related increases in flow rates, negligible correlations were found for the EZ-IO tibia in all time frames (c = 0.107–0.366; p≤0.013), moderate positive correlations were found for the EZ-IO humerus after 5 minutes (c = 0.489; p = 0.021) and strong positive correlations were found for the FASTR in all time frames (c = 0.63–0.80; p≤0.007). Post-hoc statistical power was 0.62 with the given sample size.

Conclusions

The experiments with first-time users applying EZ-IO and FASTR in body donors indicate that both devices may be effective intraosseous infusion devices, likely suitable for fluid resuscitation using a pressure bag. Variations in flow rate may limit their reliability. Larger sample sizes will prospectively be required to substantiate our findings.  相似文献   

14.

Background

Digital rectal examination (DRE) has been traditionally recommended to evaluate acute appendicitis, although several reports indicate its lack of utility for this diagnosis. No meta-analysis has examined DRE for diagnosis of acute appendicitis.

Objectives

To assess the role of DRE for diagnosis of acute appendicitis.

Data Sources

Cochrane Library, PubMed, and SCOPUS from the earliest available date of indexing through November 23, 2014, with no language restrictions.

Study Selection

Clinical studies assessing DRE as an index test for diagnosis of acute appendicitis.

Data Extraction and Synthesis

Two independent reviewers extracted study data and assessed the quality, using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Bivariate random-effects models were used for the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio (DOR) as point estimates with 95% confidence intervals (CI).

Main Outcomes and Measures

The main outcome measure was the diagnostic performance of DRE for diagnosis of acute appendicitis.

Results

We identified 19 studies with a total of 7511 patients. The pooled sensitivity and specificity were 0.49 (95% CI 0.42–0.56) and 0.61 (95% CI 0.53–0.67), respectively. The positive and negative likelihood ratios were 1.24 (95% CI 0.97–1.58) and 0.85 (95% CI 0.70–1.02), respectively. The DOR was 1.46 (0.95–2.26).

Conclusion and Relevance

Acute appendicitis cannot be ruled in or out through the result of DRE. Reconsideration is needed for the traditional teaching that rectal examination should be performed routinely in all patients with suspected appendicitis.  相似文献   

15.

Introduction

The importance of coagulation, hematology, and biochemical variables have been investigated in the stroke population but have not been systemically surveyed in cerebellar hemorrhage (CH) population. The aim of the study was to explore the predictive value of these factors for early outcome in this population.

Materials and Methods

Eighty patients with acute spontaneous CH were retrospectively analyzed. Clinical and laboratory data were collected on admission for analysis. The patients were divided by Glasgow outcome scale (GOS) score at discharge into the good outcome group (GOS score 4 or 5) and the poor outcome group (GOS score 1, 2, or 3). The association between early outcome and clinical or laboratory variables were investigated by binary logistic regression.

Results

There were 46 (57.5%) patients in the poor outcome group and 34 (42.5%) in the good outcome group. The platelet count (PC) was significantly lower in the poor outcome group (187.3 ± 53.0 × 109/l) compared with good outcome group (244.9 ± 63.9 × 109/l) (p < 0.001). Moreover, PC (OR 0.97; p = 0.004) was the strong predictor with poor early outcome.

Conclusions

We firstly show that lower PC is the independent predictor for poor early outcome in patients with spontaneous CH.  相似文献   

16.

Background

Obesity is a global public health problem and a risk factor for several diseases that financially impact healthcare systems.

Objective

To estimate the direct costs attributable to obesity (body mass index {BMI} ≥ 30 kg/m2) and morbid obesity (BMI ≥ 40 kg/m2) in adults aged ≥ 20 incurred by the Brazilian public health system in 2011.

Settings

Public hospitals and outpatient care.

Methods

A cost-of-illness method was adopted using a top-down approach based on prevalence. The proportion of the cost of each obesity-associated comorbidity was calculated and obesity prevalence was used to calculate attributable risk. Direct healthcare cost data (inpatient care, bariatric surgery, outpatient care, medications and diagnostic procedures) were extracted from the Ministry of Health information systems, available on the web.

Results

Direct costs attributable to obesity totaled US$ 269.6 million (1.86% of all expenditures on medium- and high-complexity health care). The cost of morbid obesity accounted for 23.8% (US$ 64.2 million) of all obesity-related costs despite being 18 times less prevalent than obesity. Bariatric surgery costs in Brazil totaled US$ 17.4 million in 2011. The cost of morbid obesity in women was five times higher than it was in men.

Conclusion

The cost of morbid obesity was found to be proportionally higher than the cost of obesity. If the current epidemic were not reversed, the prevalence of obesity in Brazil will increase gradually in the coming years, as well as its costs, having serious implications for the financial sustainability of the Brazilian public health system.  相似文献   

17.

Purpose

To evaluate the ability of longitudinal Useful Field of View (UFOV) and simulated driving measurements to predict future occurrence of motor vehicle collision (MVC) in drivers with glaucoma.

Design

Prospective observational cohort study.

Participants

117 drivers with glaucoma followed for an average of 2.1 ± 0.5 years.

Methods

All subjects had standard automated perimetry (SAP), UFOV, driving simulator, and cognitive assessment obtained at baseline and every 6 months during follow-up. The driving simulator evaluated reaction times to high and low contrast peripheral divided attention stimuli presented while negotiating a winding country road, with central driving task performance assessed as “curve coherence”. Drivers with MVC during follow-up were identified from Department of Motor Vehicle records.

Main Outcome Measures

Survival models were used to evaluate the ability of driving simulator and UFOV to predict MVC over time, adjusting for potential confounding factors.

Results

Mean age at baseline was 64.5 ± 12.6 years. 11 of 117 (9.4%) drivers had a MVC during follow-up. In the multivariable models, low contrast reaction time was significantly predictive of MVC, with a hazard ratio (HR) of 2.19 per 1 SD slower reaction time (95% CI, 1.30 to 3.69; P = 0.003). UFOV divided attention was also significantly predictive of MVC with a HR of 1.98 per 1 SD worse (95% CI, 1.10 to 3.57; P = 0.022). Global SAP visual field indices in the better or worse eye were not predictive of MVC. The longitudinal model including driving simulator performance was a better predictor of MVC compared to UFOV (R2 = 0.41 vs R2 = 0.18).

Conclusions

Longitudinal divided attention metrics on the UFOV test and during simulated driving were significantly predictive of risk of MVC in glaucoma patients. These findings may help improve the understanding of factors associated with driving impairment related to glaucoma.  相似文献   

18.

Background

The pulmonary residence time of inhaled glucocorticoids as well as their rate and extend of absorption into systemic circulation are important facets of their efficacy-safety profile. We evaluated a novel approach to elucidate the pulmonary absorption of an inhaled glucocorticoid. Our objective was to monitor and compare the combined process of drug particle dissolution, pro-drug activation and time course of initial distribution from human lung tissue into plasma for two different glucocorticoid formulations.

Methods

We chose beclomethasone dipropionate (BDP) delivered by two different commercially available HFA-propelled metered dose inhalers (Sanasthmax®/Becloforte™ and Ventolair®/Qvar™). Initially we developed a simple dialysis model to assess the transfer of BDP and its active metabolite from human lung homogenate into human plasma. In a novel experimental setting we then administered the aerosols into the bronchus of an extracorporally ventilated and reperfused human lung lobe and monitored the concentrations of BDP and its metabolites in the reperfusion fluid.

Results

Unexpectedly, we observed differences between the two aerosol formulations Sanasthmax®/Becloforte™ and Ventolair®/Qvar™ in both the dialysis as well as in the human reperfusion model. The HFA-BDP formulated as Ventolair®/Qvar™ displayed a more rapid release from lung tissue compared to Sanasthmax®/Becloforte™. We succeeded to explain and illustrate the observed differences between the two aerosols with their unique particle topology and divergent dissolution behaviour in human bronchial fluid.

Conclusion

We conclude that though the ultrafine particles of Ventolair®/Qvar™ are beneficial for high lung deposition, they also yield a less desired more rapid systemic drug delivery. While the differences between Sanasthmax®/Becloforte™ and Ventolair®/Qvar™ were obvious in both the dialysis and lung perfusion experiments, the latter allowed to record time courses of pro-drug activation and distribution that were more consistent with results of comparable clinical trials. Thus, the extracorporally reperfused and ventilated human lung is a highly valuable physiological model to explore the lung pharmacokinetics of inhaled drugs.  相似文献   

19.

Background

Peak oxygen uptake (VO2peak) via cardiopulmonary exercise testing is considered the gold standard for testing aerobic capacity in healthy participants and people with various medical conditions. The reliability and responsiveness of cardiopulmonary exercise testing outcomes in persons with MS (PwMS) have not been extensively studied.

Objective

(1) to investigate the reliability of cardiopulmonary exercise parameters in PwMS; (2) to determine the responsiveness, in terms of the smallest detectable change (SDC), for each parameter.

Design

Two repeated measurements of cardiopulmonary exercise outcomes were obtained, with a median time interval of 16 days.

Methods

Thirty-two PwMS suffering from subjective fatigue performed cardiopulmonary exercise tests on a cycle ergometer, to voluntary exhaustion. We calculated the reliability, in terms of the intra-class correlation coefficient (ICC [2,k]; absolute agreement), and the measurement error, in terms of standard error of measurement (SEM) and SDC at individual (SDCindividual) and group level (SDCgroup).

Results

The ICC for VO2peak was 0.951, with an SEM of 0.131 L∙min−1 and an SDCindividual of 0.364 L∙min−1. When corrected for bodyweight, the ICC of VO2peak was 0.933, with an SEM of 1.7 mL∙kg−1∙min−1 and in an SDCindividual of 4.6 mL∙kg−1∙min−1.

Limitations

Generalization of our study results is restricted to fatigued PwMS with a low to mild level of disability.

Conclusions

At individual level, cardiopulmonary exercise testing can be used reliably to assess physical fitness in terms of VO2peak, but less so to determine significant changes. At group level, VO2peak can be reliably used to determine physical fitness status and establish change over time.  相似文献   

20.

Objective

To study the oxygen saturation profile in normal Asian Indian eyes.

Design

A cross sectional prospective study.

Subjects

Ninety eight consecutive patients presenting to our hospital with best corrected distance visual acuity (BCVA) of 20/20 and a normal ophthalmic examination were included in the study. Patients having any ocular or systemic disease were excluded from the study.

Materials and Methods

Oximetry was performed on all subjects with the Oxymap T1 retinal oximeter (Oxymap hf, Reykjavik, Iceland).

Main Outcome Measures

The images were analysed for oxygen saturation and diameter.

Results

The mean age was 33 years (Range: 18-63; SD: 12.4). The average arteriolar saturation was 90.3 ± 6.6% and the venous saturation was 56.9% ± 6.3. The average A-V (arterio-venous) difference was 33.2% ± 5.2. There was an increase in arteriolar (R2 = 0.264; p=0.001) and venous saturation (R2 = 0.151; p=0.001) with age. There was no significant change in the arterio-venous saturation difference (AVSD). The inferotemporal quadrant had the lowest saturations. Age correlated positively with ocular perfusion pressure (OPP)(R2 = 0.07; p=0.007). OPP correlated positively with global arteriolar saturation (R2=0.057, p=0.018).

Conclusion

This study provides the normative database for an Indian population and is comparable to previous studies. Age, vessel diameter and OPP were the significant factors that influenced the saturation. Arteriolar and venous saturations increased with age while the AVSD did not change significantly.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号