首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Legionella is ubiquitous in many environments. At least 50 species and 70 serogroups of the Gram-negative bacterium have been identified. Of the 50 species, 20 are pathogenic, and Legionella pneumophila is responsible for the great majority (approximately 90%) of the Legionnaires'' disease cases that occur. Furthermore, of the 15 L. pneumophila serogroups identified, O1 alone causes more than 84% of the Legionnaires'' disease cases that occur worldwide. Rapid and reliable assays for the detection and identification of L. pneumophila in water, environmental, and clinical samples are in great demand. L. pneumophila bacteria are traditionally identified by their O antigens by immunological methods. We have recently developed an O serogroup-specific DNA microarray for the detection of all 15 distinct O-antigen forms of L. pneumophila, including serogroups O1 to O15. A total of 35 strains were used to verify the specificity of the microarray, including 15 L. pneumophila O-antigen standard reference strains and seven L. pneumophila clinical isolates as target strains, seven reference strains of other non-pneumophila Legionella species as closely related strains, and six non-Legionella bacterial species as nonrelated strains. The detection sensitivity was 1 ng of genomic DNA or 0.4 CFU/ml in water samples with filter enrichment and plate culturing. This study demonstrated that the microarray allows specific, sensitive, and reproducible detection of L. pneumophila serogroups. To the best of our knowledge, this is the first report of a microarray serotyping method for all 15 distinct O-antigen forms of L. pneumophila.  相似文献   

2.
Three detection methods for Legionella species in water samples from cooling towers and a river were examined. Direct counting of bacteria stained with fluorescent antibody (FA) for L. pneumophila (serogroups 1 to 6) could detect the cell of 104 to 106 cell/100 ml in all 14 samples, while colony counting method detected 10 to 103 CFU/100 ml only in 8 samples from cooling towers. Polymerase chain reaction (PCR) assay with primers to amplify 16S ribosomal DNA sequence of most Legionella species (LEG primer) detected legionellae in 13 samples, while species-specific primers for L. pneumophila detected the DNAs from 3 samples. In laboratory examination, LEG primers could amplify DNAs of 29 species of genus Legionella with high sensitivity, even from 1 cell of L. pneumophila GIFU 9134. The PCR assay with LEG primers was specific and sensitive methods to be satisfied the survey of legionellae. Thus, PCR assay is a suitable method to detect and monitor Legionella species in an environment.  相似文献   

3.
Forty-six strains ofLegionella species were assayed for plasmid DNA content using routine laboratory procedures. Large-molecular-weight cryptic plasmids were detected inLegionella pneumophila serogroups 2, 3, and 4,L. bozemanii, L. dumoffii, L. micdadei, L. gormanii, L. longbeachae, and as yet unclassifiedLegionella-like organisms. No plasmids were found in strains ofL. pneumophila serogroups 1, 5, and 6. No correlations could be made between the possession of a specific plasmid profile, or lack of one, and any phenotypic markers such as virulence or antibiotic resistance. Several parameters were identified in this study as critical to the isolation of plasmid DNA fromLegionella: (i) DNA preparations obtained from frozen egg or animal materials had a higher incidence of detectable plasmid DNA than subcultures on bacteriologic media. (ii) A newly formulated broth supported exponential growth in all of the 46 strains; one strain required the addition of CO2. (iii) Considerable heterogeneity was seen in cell susceptibility to various detergents. Since no single lytic agent was suitable for all strains, both ionic and noninic lysis methods were used with each strain. Within the limitations of both crude lysate preparations and the agarose gel electrophoresis method, this study identified a large 60–80 megadalton plasmid species in over 50% of the plasmid-containing strains.  相似文献   

4.
5.
Three Legionella pneumophila strains isolated from water samples and belonging to serogroups (sgs) 1, 6 and 9 were analysed for their capacity to colonise an experimental model simulating a domestic hot water distribution system. Ecological factors that could influence the persistence of the sgs such as intracellular life within protozoan hosts and bacterial interference by the production of antagonistic compounds were also studied. Viable counts of L. pneumophila increased both in the planktonic and in the sessile phases. Sg 6 showed a marked prevalence during the whole experiment and exhibited the highest host infection efficiency. Sg 1 was significantly less represented, but showed the highest capacity to reproduce in the protozoan hosts. Sg 9 was poorly represented and less adapted to intracellular life. Among the 14 bacteria constantly isolated in the system, five (35.7%) produced antagonistic substances against Legionella, with differences according to the bacterial strain and L. pneumophila sgs.  相似文献   

6.
7.
Chemical composition of a lipopolysaccharide from Legionella pneumophila   总被引:7,自引:0,他引:7  
Lipopolysaccharide isolated from Legionella pneumophila (Phil. 1) was examined for chemical composition. The polysaccharide split off by mild acid hydrolysis contained rhamnose, mannose, glucose, quinovosamine, glucosamine and 2-keto-3-deoxyoctonate, in molar proportions 1.6:1.8:1.0:1.5:4.1:2.7. Heptoses were absent and glucose was probably mainly phosphorylated. The carbohydrate backbone of the lipid A part consisted of glucosamine, quinovosamine and glycerol, in the molar ratios 3.9:1.0:3.4, with glycerol as a phosphorylated moiety. A complex fatty acid substitution pattern comprising eight O-ester-linked, exclusively nonhydroxylated acids, and nineteen amide-linked, exclusively 3-hydroxylated acids was revealed. Both straight- and branched (iso and anteiso) carbon chains occurred. The major hydroxy fatty acid was 3-hydroxy-12-methyltridecanoic acid and six others were of a chain-length above 20 carbon atoms, with 3-hydroxy-20-methyldocosanoic acid as the longest. Two dihydroxy fatty acids, 2,3-dihydroxy-12-methyltridecanoic and 2,3-dihydroxytetradecanoic acids, were also detected. These results suggest that L. pneumophila contains a rather complex and unusual lipopolysaccharide structure of considerable biological and chemotaxonomic interest.Abbreviations LPS lipopolysaccharide - PS polysaccharide - KDO 2-keto-3-deoxy-octonate - GC gas chromatography - GC-MS gas chromatograph-mass spectrometer combined instrument - CI chemical ionization - EI electron impact - HF hydrofluoric acid - TFA trifluoroacetyl - TMS trimethylsilyl  相似文献   

8.
Based on comparative sequence analysis, we have designed an oligonucleotide probe complementary to a region of 16S rRNA of Legionella pneumophila which allows the differentiation of L. pneumophila from other Legionella species without cultivation. The specificity of the new probe, LEGPNE1, was tested by in situ hybridization to a total of four serogroups of six strains of L. pneumophila, five different Legionella spp. and three nonlegionella species as reference strains. Furthermore, L. pneumophila cells could be easily distinguished from Legionella micdadei and Pseudomonas aeruginosa cells by using in situ hybridization with probes LEGPNE1, LEG705, and EUB338 after infection of the protozoan Acanthamoeba castellanii.  相似文献   

9.
The aim of this study was to compare the occurrence of L. pneumophila in hot water samples from hot water tanks and instantaneous devices. Tanks and devices were all operated by heat exchangers employed in the town's district heating system. Thirty-six out of 171 (21%) hot water samples tested positive for L. pneumophila isolation, with 14.6% belonging to serogroup 1 and 6.4% to serogroups 2–14. The proportion of L. pneumophila detected in hot water reservoirs (30%) was higher than that observed in hot water instantaneous devices (6.2%). Differences in L. pneumophila isolation reflected different temperatures registered at the faucet: ≤50°C for hot water from reservoir devices, and >60°C for hot water from instantaneous devices. These data emphasize the need to control temperature in hot water distribution devices, thus inhibiting the formation of biofilm and L. pneumophila colonization. Received: 4 April 2000 / Accepted: 31 May 2000  相似文献   

10.
A total of 25 gyrB gene sequences from 20 Legionella pneumophila subsp. pneumophila strains and five L. pneumophila subsp. fraseri strains were obtained and analyzed, and a multiplex PCR for the simultaneous detection of Legionella bozemanae, Legionella longbeachae, Legionella micdadei and Legioenella pneumophila, and two single PCRs for the differentiation of L. pneumophila subsp. pneumophila and L. pneumophila subsp. fraseri were established. The multiplex PCR method was shown to be highly specific and reproducible when tested against 41 target strains and 17 strains of other bacteria species. The sensitivity of the multiplex PCR was also analyzed and was shown to detect levels as low as 1 ng of genomic DNA or 10 colony-forming units (CFUs) per milliliter in mock water samples. Sixty-three air conditioner condensed water samples from Shanghai City were examined, and the result was validated using 16S rRNA sequencing. The data reported here demonstrate that the multiplex PCR method described is efficient and convenient for the detection of Legionella species in water samples. Twenty L. pneumophila subsp. pneumophila strains and five L. pneumophila subsp. fraseri strains were used for the validation of the two L. pneumophila subspecies-specific PCR methods, and the results indicated that the two PCR methods were both highly specific and convenient for the identification of L. pneumophila at the subspecies level.  相似文献   

11.
Structure of the O-specific polysaccharide chain of the lipopolysaccharide (LPS) of Shewanella japonica KMM 3601 was elucidated. The initial and O-deacylated LPS as well as a trisaccharide representing the O-deacetylated repeating unit of the O-specific polysaccharide were studied by sugar analysis along with 1H and 13C NMR spectroscopy. The polysaccharide was found to contain a rare higher sugar, 5,7-diacetamido-3,5,7,9-tetradeoxy-d-glycero-d-talo-non-2-ulosonic acid (a derivative of 4-epilegionaminic acid, 4eLeg). The following structure of the trisaccharide repeating unit was established: →4)-α-4eLegp5Ac7Ac-(2→4)-β-d-GlcpA3Ac-(1→3)-β-d-GalpNAc-(1→.  相似文献   

12.
Three Legionella pneumophila strains isolated from municipal hot tap water during a multicentric Italian survey and belonging to serogroups 1, 6, 9 and the reference strain Philadelphia-1 were studied to determine the intracellular replication capability and the cytopathogenicity in human monocyte cell line U937 and in an Acanthamoeba polyphaga strain. Our results show that both serogroups 1 and Philadelphia-1 were able to multiply into macrophages inducing cytopathogenicity, while serogroup 6 and ever more serogroup 9 were less efficient in leading to death of the infected macrophages. Both serogroups 1 and 6 displayed a quite good capability of intracellular replication in A. polyphaga, although serogroup 1 was less cytopathogenic than serogroup 6. Serogroup 9, like Philadelphia-1 strain, showed a reduced efficiency of infection and replication and a low cytopathogenicity towards the protozoan. Our study suggests that bacterial pathogenesis is linked to the difference in the virulence expression of L. pneumophila serogroups in both hosts, as demonstrated by the fact that only L. pneumophila serogroup 1 shows the contextual expression of the two virulence traits. Serogroup 6 proves to be a good candidate as pathogen since it shows a good capacity for intracellular replication in protozoan.  相似文献   

13.
This study presents the potential of a biological control of Legionella pneumophila. It was verified to what extent the enrichment of various Bacillus species in water may decrease or prevent L. pneumophila from growing in water. During in vitro tests, B. subtilis BS104 was able to induce an average decrease in L. pneumophila numbers of 1.9 + 0.2 log units after 120 h. Furthermore, the spore and cell free filtrate of B. subtilis BS104 also decreased L. pneumophila by 2.6 + 0.4 log units after 120 h. An addition of Bacillus BS104 to a cooling tower test system with a water volume of 8 m3 resulted in a L. pneumophila level below 1000 CFU/L after 3 weeks, whereas the starting point was 5.3 × 104 CFU/L. Further experiments also indicated that B. subtilis BS104 might inhibit the internal replication of L. pneumophila in Acanthamoeba castellanii. This paper demonstrates that certain strains of Bacillus have the potential of reducing the number of viable L. pneumophila in water, or at least prevent its increase. These results are the first indication that a biological abatement of L. pneumophila could be possible.  相似文献   

14.
On mild acid degradation of the lipopolysaccharide of Escherichia coli O108, the O-polysaccharide was isolated and studied by sugar analysis and one- and two-dimensional 1H- and 13C-NMR spectroscopy. The polysaccharide was found to contain an unusual higher sugar, 5,7-diacetamido-3,5,7,9-tetradeoxy-l-glycero-d-galacto-non-2-ulosonic acid (di-N-acetyl-8-epilegionaminic acid, 8eLeg5Ac7Ac). The following structure of the tetrasaccharide repeating unit of the polysac-charide was established: →4)-α-8eLegp5Ac7Ac-(2→6)-α-D-Galp-(1→3)-α-L-FucpNAc-(1→3)-α-D-GlcpNAc-(1→. Functions of the E. coli O108 antigen biosynthetic genes, including seven putative genes for synthesis of 8eLeg5Ac7Ac, were assigned by sequencing the O-antigen gene cluster along with comparison with gene databases and known biosynthetic pathways for related nonulosonic acids.  相似文献   

15.
Illnesses of undiagnosed etiology among researchers exposed to lakes and streams in the Mt. St. Helens blast zone after the 18 May 1980 eruption prompted us to determine the occurrence and potential virulence ofLegionella (Legionnaries' disease bacteria) in aquatic habitats near Mt. St. Helens during the summers of 1981 and 1982. Concentrations ofL. pneumophila, L. micdadei, L. gormanii, L. dumoffii, andL. bozemanii, determined by microscopic counts using direct immunofluorescent staining, ranged from <104 to 105 cells/l in lakes and rivers outside the Mt. St. Helens blast zone while the numbers ofLegionella in aquatic habitats inside the blast zone were from 105 to 107 cells/l.Legionella numbers were consistently highest in North Coldwater and Spirit lakes, which received water from hydrothermal seeps.Legionella pneumophila serogroups 4 and 6 were isolated from North Coldwater Lake in 1981 and from South Coldwater Creek in 1982, indicating that potentially virulent strains ofLegionella persist in aquatic habitats in the blast zone of Mt. St. Helens.Technical paper no. 6923, Oregon Agricultural Experiment Station.  相似文献   

16.
A new method for the rapid and sensitive detection of Legionella pneumophila in hot water systems has been developed. The method is based on an IF assay combined with detection by solid-phase cytometry. This method allowed the enumeration of L. pneumophila serogroup 1 and L. pneumophila serogroups 2 to 6, 8 to 10, and 12 to 15 in tap water samples within 3 to 4 h. The sensitivity of the method was between 10 and 100 bacteria per liter and was principally limited by the filtration capacity of membranes. The specificity of the antibody was evaluated against 15 non-Legionella strains, and no cross-reactivity was observed. When the method was applied to natural waters, direct counts of L. pneumophila were compared with the number of CFU obtained by the standard culture method. Direct counts were always higher than culturable counts, and the ratio between the two methods ranged from 1.4 to 325. Solid-phase cytometry offers a fast and sensitive alternative to the culture method for L. pneumophila screening in hot water systems.  相似文献   

17.
Legionella pneumophila is a strict intracellular pathogen that replicates in the professional phagocytes of the human and guinea pig host. Although murine macrophages from most inbred strains are non-permissive to intracellular replication of L. pneumophila, inflammatory macrophages from the mouse strain A/J are completely permissive to intracellular replication of this bacterium. This genetic difference is controlled by the expression of a single autosomal gene designated Lgn1, with non-permissiveness behaving as completely dominant over permissiveness. We have used a total of 25 AXB/BXA recombinant inbred mouse strains and 182 (A/JxC57BL/6J)xA/J segregating backcross progeny (A/J, permissive; C57BL/6J, non-permissive) to map the Lgn1 gene. Animals were individually type for tolerance to intracellular replication by in vitro infection of their inflammatory macrophages with L. pneumophila. All animals segregated into two non-overlapping groups. Examination of the strain distribution pattern of the AXB/BXA strains for Lgn1 initially identified linkage to Chromosome (Chr) 13 markers. Genotyping of the 25 AXB/BXA strains and the 182 backcross progeny for 11 Chr 13 markers established that Lgn1 mapped to Chr 13, with the gene order and intergene distance D13Mit231-(5.5±1.5)-D13Mit193-(2.2±0.9)-D13Mit194-(1.1±0.6)-D13Mit128-(2.6±1.0)-Lgn1-(2.2±0.9)-D13Mit70-(3.9±1.3)-D13Mit73-(7.2±1.7)-D13Mit53-(0.7±0.5)-D13Mit32-(0.7±0.5)-D13Mit77-(0.7±0.5)-D13Mit78. This portion of Chr 13 is homologous to the distal portion of human Chr 5, 5q11–5q13, suggesting a possible location of a human LGN1 homolog. Understanding the molecular basis of the high permissiveness of A/J macrophage to L. pneumophila may shed light on the survival strategy of this bacterium in highly permissive human phagocytes. This may be achieved by positional cloning of Lgn1, and the identification of the Lgn1 subchromosomal region reported here is a first step towards that goal.  相似文献   

18.
Aims: This study was designed to evaluate the usefulness of quantification by real‐time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90‐431). Methods and Results: Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 105 GU l?1) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57–100% of the samples. Conclusions: These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real‐time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. Significance and Impact of the Study: This study shows the possibility of using real‐time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters.  相似文献   

19.
Efficacy of Gemacide PN-50TM (a quaternary ammonium compound) as a commercial formulation recommended for disinfecting heat exchangers was determined for both planktonic and sessile populations of variousLegionella pneumophila strains. The quaternary ammonium compound (QAC) was preferred as an alternative due to the emerging resistance of potentially pathogenic bacteria against different biocides. PlanktonicL. pneumophila strains were suspended in tap water while sessile ones were grown on stainless steel that is used in construction of the cooling towers, then both group of strains were exposed to the biocide. The sensitivity of both planktonic and sessile populations ofL. pneumophila strains to the biocide was different. The biocide was found effective below recommended dosages (1000–2000 mg/L) against planktonic populations ofL. pneumophila, whereas it was determined that higher than the recommended dosages were required for sessile populations. The environmental isolates were more resistant to the biocide than the ATCC isolate was. The results indicated that studying only the planktonic populations ofL. pneumophila for biocide tests might not be sufficient to provide the optimum dosage and contact time information for field trials. Therefore, biocidal activity of a water treatment chemical must be evaluated in terms of dosage and contact times on both planktonic and sessile bacteria.  相似文献   

20.
Serological studies using SDS-PAGE and immunoblotting revealed that from five strains that are ascribed to Citrobacter serogroup O2, four strains, PCM 1494, PCM 1495, PCM 1496 and PCM 1507, are reactive with specific anti-Citrobacter O2 serum. In contrast, strain PCM 1573 did not react with anti-Citrobacter O2 serum and, hence, does not belong to serogroup O2. The LPS of Citrobacter youngae O2a,1b (strain PCM 1507) was degraded under mild acidic conditions and the O-specific polysaccharide (OPS) released was isolated by gel chromatography. Sugar and methylation analyses along with (1)H- and (13)C-NMR spectroscopy, including two-dimensional (1)H,(1)H COSY, TOCSY, NOESY and (1)H,(13)C HSQC experiments, showed that the repeating unit of the OPS has the following structure: [structure: see text]. NMR spectroscopic studies demonstrated that Citrobacter werkmanii O20 and C. youngae O25 have the same OPS structure as C. youngae O2. Sugar and methylation analyses of the core oligosaccharide fractions demonstrated structural differences in the lipopolysaccharide core regions of these strains, which may substantiate their classification in different serogroups.  相似文献   