首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
A novel isocratic reversed-phase high performance liquid-chromatography/ultraviolet detection method for simultaneous determination of cefdinir and cefixime in human plasma was developed and validated after optimization of various chromatographic conditions and other experimental parameters. Sample preparation based on a simple extraction procedure consisting of deproteination and extraction with 3 parts of 6% trichloroacetic acid aqueous solution followed by volume make up with the aqueous component of the mobile phase obtained best recoveries of the two analytes. Samples were separated on a Supelco Discovery HS C(18) (150 mm × 4.6 mm, 5 μm) analytical column protected by a Perkin Elmer C(18) (30 mm × 4.6 mm, 10 μm) guard cartridge. The mobile phase, methanol/acetonitrile (50/50, v/v):0.05% trifluoroacetic acid (19:81, v/v), operated at 50°C column oven temperature was pumped at a flow rate of 2.0 mL min(-1) and the column eluents were monitored at a wavelength of 285 nm. When Sample was injected into the Perkin Elmer high performance liquid-chromatography system through Rheodyne manual (or auto-sampler) injector equipped with 20 μL loop, separation was achieved within 4 min. The present method demonstrated acceptable values for selectivity, linearity within the expected concentration range (0.004-5.0 μg mL(-1); r(2)>0.999 for both analytes), recovery (>95% for cefdinir and >96% for cefixime), precision (%RSD<2.0 for cefdinir and <2.2 for cefixime), sensitivity (limit of detection: 1 ng mL(-1) and lower limit of quantification: 4 ng mL(-1) for both analytes), stability of solutions, and robustness. The method was efficiently applied to a pharmacokinetic study in healthy volunteers.  相似文献   

2.
A new method has been developed that is capable of providing a complete profile of the most common monothiols and disulfides present in plasma or tissue extracts. The method utilizes reversed phase ion-pairing high performance liquid chromatography coupled with coulometric electrochemical detection to simultaneously quantify free oxidized and reduced aminothiols or total aminothiols after chemical reduction. The method is extremely sensitive, with limits of detection in the 5 fmol/mL range for monothiols and 50 fmol/mL for dithiols. The interassay and intraassay coefficients of variation for total and free aminothiols ranged between 1.2 and 5.8%. The mean recoveries for total and plasma aminothiols ranged between 97.1 and 102.8%. The aminothiols are quantified directly, without derivatization, and include methionine, homocysteine, homocystine, cystathionine, cysteine, cystine, cysteinylglycine, and oxidized and reduced glutathione. Because a complete aminothiol profile of metabolites in both the remethylation (anabolic) and transulfuration (catabolic) pathways of homocysteine metabolism can be determined simultaneously, this new method should be useful in determining the metabolic etiology of homocysteinemia and in designing appropriate nutritional intervention strategies. Basic research applications of this method should lead to an increased understanding of the metabolic pathology of aminothiol imbalance.  相似文献   

3.
A fast, simple and selective HPLC method has been developed for the assay of aciclovir, ganciclovir, and penciclovir in human plasma by coupling HPLC with fluorescence detection. 200 microl plasma, with guanosine 5'-monophosphate as an internal standard, was subjected to protein precipitation with a 7% [v/v] aqueous perchloric acid solution. The 40 microl supernatant was injected into a Diamonsil-5 microm C18 column. Aciclovir, ganciclovir, and penciclovir, with solvents composed of methanol and 0.08% aqueous trifluoroacetic acid solution, were analysed by fluorescence detection at 260 nm (excitation) and 380 nm (emission) using a gradient elution program. The calibration curves of all three analytes were linear between 20 and 2000 ng/ml. The mean absolute recoveries of aciclovir, ganciclovir, and penciclovir were 93.91+/-1.20%, 97.42+/-0.75%, and 99.01+/-3.30%, respectively. The mean inter-day CVs for aciclovir, ganciclovir, and penciclovir, were within 1.29-7.30%, 1.00-5.53%, and 1.19-3.54%, respectively. The intra-day bias for aciclovir, ganciclovir, and penciclovir ranged from -2.01 to 6.33%, 1.81 to 7.37%, and 1.42 to 6.91%, respectively. The method has been validated and applied in pharmacokinetic studies in Chinese adult renal transplant patients.  相似文献   

4.
Each year in the USA approximately 7-8 million patients with non-traumatic chest pain come to hospital emergency rooms. It is estimated that approximately 2-5% of these patients are experiencing cardiac ischaemia, but due to the shortcomings of the available testing methods they are incorrectly diagnosed and discharged without appropriate therapy having been provided. Preliminary data with a globally ischaemic mouse heart model has demonstrated that endogenous inosine might be a potential biomarker of initial cardiac ischaemia before cardiac tissue necrosis. A high-performance liquid chromatographic diode array detection (HPLC-DAD) method was utilized for the detection and quantification of inosine in Krebs-Henseleit (Krebs) buffer solution perfusing from surgically removed and isolated mouse hearts undergoing global cardiac ischaemia. A C18 column at a flow rate of 0.6 ml min-1 with an aqueous mobile phase of trifluoroacetic acid (0.05% trifluoroacetic acid in deionized water, pH 2.2, v/v) and methanol gradient was used for component separation. The assay detection limit for inosine in Krebs buffer solution was 500 ng ml-1 using a 100-µl neat injection. The HPLC results were used to determine total cardiac effluxed inosine into the Krebs effluent for each mouse during oxidative stress and compared with the per cent cardiac ventricular functional recovery rate to determine if a relationship exists amongst this cardiovascular parameter during periods of cardiac oxidative stress.  相似文献   

5.
A sensitive and selective ion-pair liquid chromatography-tandem mass spectrometric method (IP-LC-MS/MS) for the simultaneous determination of amodiaquine (AQ) and its active metabolite, N-desethylamodiaquine (AQm), in human blood has been developed and validated. Pentafluoropropionic acid (PFPA) was applied as ion-pairing reagent in reversed-phase chromatographic separation. The effects of PFPA concentrations and the volume fraction of acetonitrile in the mobile phase on the retention of analytes were investigated on a Venusil MP-C(18) column, and the mobile phase was finally optimized as acetonitrile:water (23:77, v/v) with 0.0667% PFPA in the aqueous phase. The results proved that PFPA as an ion-pairing reagent could provide desirable chromatographic performance in the IP-LC-MS/MS determination of 4-aminoquinoline compounds. Blood samples were protein precipitated with acetonitrile using hydroxychloroquine (OHCQ) as the internal standard. The detection was carried out in multiple reaction monitoring (MRM) mode via positive atmospheric pressure chemical ionization (APCI) interface. The lower limits of quantification were established at 0.150 and 1.50 ng/mL for AQ and AQm, respectively. The validated IP-LC-MS/MS method was applied to a clinical pharmacokinetic study of AQ and AQm in human blood after an oral administration of 600 mg AQ hydrochloride (45 9mg base).  相似文献   

6.
7.
A highly selective, sensitive and rapid HPLC method has been developed and validated to quantify tadalafil in human plasma. The tadalafil and internal standard (loratadine, I.S.) were extracted by liquid-liquid extraction technique followed by an aqueous back-extraction allowing injection of an aqueous solvent in the HPLC system. The chromatographic separation was performed on a reverse phase BDS Hypersil C-18 column (250 mm x 4.6 mm, 5 microm, Thermo Separation Co., USA) with a mobile phase of acetonitrile and aqueous solution containing 0.012 M triethylamine+0.020 M orthophosphoric acid (50/50, v/v). The analytes were detected at 225 nm. The assay exhibited a linear range of 5-600 ng/mL for tadalafil in human plasma. The lower limit of quantitation (LLOQ) was 5 ng/mL. The within- and between batch precision (expressed as coefficient of variation, C.V.) did not exceed 10.3% and the accuracy was within -7.6% deviation of the nominal concentration. The recovery of tadalafil from plasma was greater than 66.1%. Stability of tadalafil in plasma was excellent with no evidence of degradation during sample processing (auto-sampler) and 30 days storage in a freezer. This validated method is applied for the clinical study of the tadalafil in human volunteers.  相似文献   

8.
This paper evaluates the performances of reversed-phase (RPLC) and ion-pairing chromatography (IPLC) coupled with UV detection for the analysis of a set of 12 catecholamines and related compounds. Different chromatographic columns (porous C18-silica, perfluorinated C18-silica, porous graphitic carbon, monolithic and fused-core silica-based C18 columns) were tested using semi-long perfluorinated carboxylic acids as volatile ion-pairing reagents. Much more promising results were obtained by IPLC than by RPLC and important improvements in analytes peak symmetry and separation resolution were observed when using the "fast chromatography" columns (monolithic and fused-core C18) under IPLC conditions. For UV detection, a satisfactory separation of the 12 selected analytes was achieved in less than 20 min by using a fused-core particles column (Halo C18) and a mobile phase composed of a 1.25 mM nonafluoropentanoic acid aqueous solution and methanol under gradient elution mode. The chromatographic method developed can be directly coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS) in positive ionization mode and 10 solutes among those selected can be observed. The presence of the acidic ion-pairing reagent in the mobile phase makes this system incompatible with negative ionization mode and thus unable to detect the two acidic compounds that only responded in negative mode. In terms of MS detection, Monolithic C18 column proved to be the best one to reach the lowest detection limits (LODs) (from 0.5 ngmL(-1) to 10 ngmL(-1) depending on the neurotransmitter). The applicability of the optimized LC-MS/MS method to a "real world" sample was finally evaluated. The presence of the matrix leads to signal suppression for several solutes and thus to higher LODs.  相似文献   

9.
A sensitive, reproducible, and robust high-performance liquid chromatography (HPLC) method has been validated for simultaneously determining total concentrations of the aminothiols homocysteine, cysteine, cysteinylglycine, and glutathione in human plasma. Plasma aminothiols are reduced via incubation with tris-(2-carboxyethyl)-phosphine hydrochloride, followed by protein precipitation with trichloroacetic acid and derivatization with ammonium-7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonic acid. Separation of aminothiols and the internal standard mercaptopropionylglycine is achieved using reversed-phase HPLC conditions and fluorescence detection. Excellent linearity is observed for all analytes over their respective concentration ranges with correlation coefficients (r) > 0.99. The intra- and inter-day precision and accuracy were within +/-10%. This method utilizes an internal standard, employs phosphate buffered saline-based standards and quality controls, and demonstrates excellent plasma recovery and improved sensitivity. This assay is well suited for high-throughput quantitative determination of aminothiols in clinical studies, and is currently being used to support investigations of oxidative stress in patients with chronic kidney disease.  相似文献   

10.
A solid-phase extraction (SPE) method was developed using 8M urea to desorb and extract organochlorine pesticides (OCs) and polychlorinated biphenyls (PCBs) from avian serum for analysis by capillary gas chromatography with electron capture detection (GC-ECD). The analytes were efficiently extracted from the denatured serum-lipoprotein-analyte complex by one passage through an Oasis((R)) hydrophilic-lipophilic-balanced (HLB) SPE cartridge. No further clean-up was necessary, the entire extraction procedure and GC-ECD analysis can be accomplished in less than 3h. Serum volumes ranged from 100 microL to 1 mL with absolute recoveries of 90-101% for PCBs and 74% to 101% for the OC pesticides.  相似文献   

11.
Abstract

Each year in the USA approximately 7–8 million patients with non-traumatic chest pain come to hospital emergency rooms. It is estimated that approximately 2–5% of these patients are experiencing cardiac ischaemia, but due to the shortcomings of the available testing methods they are incorrectly diagnosed and discharged without appropriate therapy having been provided. Preliminary data with a globally ischaemic mouse heart model has demonstrated that endogenous inosine might be a potential biomarker of initial cardiac ischaemia before cardiac tissue necrosis. A high-performance liquid chromatographic diode array detection (HPLC-DAD) method was utilized for the detection and quantification of inosine in Krebs–Henseleit (Krebs) buffer solution perfusing from surgically removed and isolated mouse hearts undergoing global cardiac ischaemia. A C18 column at a flow rate of 0.6 ml min?1 with an aqueous mobile phase of trifluoroacetic acid (0.05% trifluoroacetic acid in deionized water, pH 2.2, v/v) and methanol gradient was used for component separation. The assay detection limit for inosine in Krebs buffer solution was 500 ng ml?1 using a 100-µl neat injection. The HPLC results were used to determine total cardiac effluxed inosine into the Krebs effluent for each mouse during oxidative stress and compared with the per cent cardiac ventricular functional recovery rate to determine if a relationship exists amongst this cardiovascular parameter during periods of cardiac oxidative stress.  相似文献   

12.
This paper aims to investigate the metabolism and pharmacokinetics of curcumin, demethoxycurcumin and bisdemethoxycurcumin in mice tumor. To improve water solubility, nanoparticle formulations were prepared as curcuminoids-loaded solid lipid nanoparticles (curcuminoids-SLNs) and curcumin-loaded solid lipid nanoparticles (curcumin-SLNs). After intragastric administration to tumor-bearing ICR mice, the plasma and tumor samples were analyzed by liquid chromatography with ion trap mass spectrometry. We discovered that curcuminoids were mainly present as glucuronides in plasma, whereas in free form in tumor tissue. A validated LC/MS/MS method was established to determine the three free curcuminoids in tumor homogenate. Samples were separated on a Zorbax SB-C(18) column, eluted with acetonitrile-water (containing 0.1% formic acid), and detected by TSQ Quantum triple quadrupole mass spectrometer in selected reaction monitoring mode. The method showed good linearity (r(2)=0.997-0.999) over wide dynamic ranges (2-6000 ng/mL). Variations within- and between-batch never exceeded 11.2% and 13.4%, respectively. The extraction recovery rates ranged from 78.3% to 87.7%. The pharmacokinetics of curcuminoids in mice tumor fit two-compartment model and first order elimination. For curcumin-SLNs group, the dosing of 250 mg/kg of curcumin resulted in AUC((0-48 h)) of 2285 ngh/mL and C(max) of 209 ng/mL. For curcuminoids-SLNs group, the dosing equivalent to 138 mg/kg of curcumin resulted in higher tumor concentrations (AUC=2811 ngh/mL, C(max)=285 ng/mL). It appeared that co-existing curcuminoids improved the bioavailability of curcumin.  相似文献   

13.
A robust and sensitive method using liquid chromatography-tandem mass spectrometry was developed and validated for the simultaneous determination of a novel topoisomerase 1 inhibitor CH0793076 (3076), the prodrug CH4556300 (TP300), and the active metabolite CH0793011 (3011) in human plasma. All plasma analyzed with this method was acidified with 1M HCl and 46% citric acid solution in a ratio of 100:10:1 (v:v:v) to avoid the pH-based degradation of TP300 and to shift the equilibria of 3076 and 3011 between the lactone and carboxylate forms towards the lactone forms. After the plasma proteins were precipitated with methanol:acetonitrile:HCl 1M (50:50:1, v:v:v) containing stable isotopic internal standards, the analytes were trapped on an Xterra MS C18 column (10×2.1 mm i.d., 5 μm) and separated on a Gemini C18 column (50×2.0 mm i.d., 5 μm) using column-switching liquid chromatography. Electrospray ionization in the positive-ion mode and multiple reaction monitoring were used to quantify the analytes with transitions m/z 587.2>441.2 for TP300, 459.1>415.2 for 3076, and 475.1>361.1 for 3011. The inter- and intra-day precisions were below 12%, and the accuracy was between -16% and 16% at the lower limit of quantitation (LLOQ) and between -11% and 14% at the other quality controls. The LLOQs of TP300, 3076, and 3011 were 0.8, 0.04, and 0.04 ng/mL, respectively. The validated method was successfully applied to clinical sample analysis and incurred sample reanalysis was also conducted.  相似文献   

14.
Glycyrrhizin (1), the main active principle of Glycyrrhiza glabra (liquorice) roots, is extensively used in herbal medicines, in pharmaceutical preparations and confectionery products. A feasible and reliable method which allows the simultaneous analysis of 1 and its aglycone, 18beta-glycyrrhetic acid (2), by means of an isocratic HPLC procedure is described. The system uses a C8 column as the stationary phase, and a mixture of acetonitrile, methanol, water and glacial acetic acid as the mobile phase. Good linearity was found in the concentration ranges 1-50 and 0.05-2.50 microg/mL for 1 and 2, respectively. A simple and rapid sample pre-treatment, based on the extraction of the two analytes with a mixture of water and ethanol, was developed for the examination of liquorice confectionery products and root samples. The HPLC method was shown to be appropriate, in terms of precision and feasibility, for the quality control of the analytes in these matrices.  相似文献   

15.
The stability constants of the supramolecular complexes formed between L ((a,b,c,d)) or their Zn(2+) complexes, and adenosine 5'-triphosphate (ATP) in aqueous solution were determined by potentiometric titrations (25 degrees C, I = 0.1 mol dm(-3) KNO(3)). The results show that protonated aliphatic-substituted L (a,d) and aromatic-substituted L (b,c) ligands and/or Zn(II) ion can efficiently recognition the substrate, ATP. All of the equilibrium studies, (1)H and (31)P nuclear magnetic resonance spectra indicate that multiple interactions, including coordination, pi-stacking, ion-pairing, H-bonding, and possible ion-pi-donor, hydrophobic and even van der Waals interactions exist in the Zn(II)-L-ATP systems. On the other hand, the recognition of the substrates by the protonated ligands was significantly promoted by the addition of Zn(II), which leads to coordination competition between the mixed ligands, L and nucleotide. In Zn(II)/L/ATP systems the tendency for phosphate chain to receive proton and metal ion increases, facilitating the cleavage of the phosphate chain of the nucleotide.  相似文献   

16.
Selective and sensitive methods for the determination of the cationic dye and anti-malarial methylene blue in human liquid whole blood, dried whole blood (paper spot), and plasma depending on protein precipitation and cation exchange chromatography coupled to electrospray ionisation (ESI) tandem mass spectrometry (MS/MS) have been developed, validated according to FDA standards, and applied to samples of healthy individuals and malaria patients within clinical studies. Acidic protein precipitation with acetonitrile and trifluoroacetic acid was used for liquid whole blood and plasma. For the extraction of methylene blue from paper spots aqueous acetonitrile was used. Sample extracts were chromatographed on a mixed mode column (cation exchange/reversed phase, Uptisphere MM1) using an aqueous ammonium acetate/acetonitrile gradient. Methylene blue was quantified with MS/MS in the selected reaction monitoring mode using ESI and methylene violet 3RAX as internal standard. Depending on the sample volume (whole blood and plasma 250 microL, and 100 microL on paper spots) the method was linear at least within 75 and 10,000 ng/mL and the limit of quantification in all matrices was 75 ng/mL. Batch-to-batch accuracies of the whole blood, plasma, and paper spot methods varied between -4.5 and +6.6%, -3.7 and +7.5%, and -5.8 and +11.1%, respectively, with corresponding precision ranging from 3.8 to 11.8% CV. After a single oral dose (500 mg) methylene blue concentrations were detectable for 72 h in plasma. The methods were applied within clinical studies to samples from healthy individuals and malaria patients from Burkina Faso.  相似文献   

17.
A novel HPLC-UV method was developed for the simultaneous determination of timolol (TM), rosuvastatin (RST), and diclofenac sodium (DS) in pharmaceuticals, human plasma and aqueous humor using naproxen sodium as internal standard (IS). The target compounds were analyzed on Hypersil BDS C(18) column (250 mm × 4.6 mm, 5 μm), applying 0.2% triethylamine (TEA) and acetonitrile (ACN) (40:60, v/v), in isocratic mode as mobile phase, pH 2.75 adjusted with 85% phosphoric acid at a flow rate of 1 ml/min. The column oven temperature was kept at 45°C and the peak response was monitored at 284 nm after injecting a 50 μl sample into HPLC system. The direct liquid-liquid extraction procedure was applied to human plasma and bovine aqueous humor samples using mobile phase as an extraction solvent after deproteination with methanol. The different HPLC experimental parameters were optimized and the method was validated according to standard guidelines. The recoveries of the suggested method in human plasma were 98.72, 96.04, and 95.14%, for TM, RST, and DS, while in aqueous humor were 94.99, and 98.23%, for TM, and DS, respectively. The LOD values were found to be 0.800, 0.500, and 0.250 ng/ml, for TM, RST, and DS, respectively, while their respective LOQ values were 2.00, 1.50, and 1.00 ng/ml. The co-efficient of variation (CV) were in the range of 0.1492-1.1729% and 1.0516-4.0104%, for intra-day and inter-day studies, respectively. The method was found accurate in human plasma and bovine aqueous humor and will be applied for the quantification of these compounds in plasma, and aqueous humor samples using animal models and in pharmaceuticals.  相似文献   

18.
Li J  Wang T  Wu D  Zhang X  Yan J  Du S  Guo Y  Wang J  Zhang A 《Biomacromolecules》2008,9(10):2670-2676
Synthesis of novel zwitterionic block copolypeptides, poly(N-isopropylacrylamide)-block-poly(L-glutamic acid-co-L-lysine) [PNiPAM(n)(PLG(x)-co-PLLys(y))m , where n is the number-average degree of polymerization (DP(n)) of PNiPAM block, x and y are the mole fraction of glutamic acid and lysine residues, respectively, and m is the total DP(n) of the peptide block], and their stimuli-responsiveness to temperature and pH variation in aqueous solutions are described. Initiated with the amino-terminated poly(N-isopropylacrylamide) (PNiPAM(n)-NH2), ring-opening polymerization (ROP) of a mixture of gamma-benzyl-L-glutamate N-carboxyanhydride (BLG-NCA), and Boc-L-lysine N-carboxyanhydride (BLLys-NCA) afforded the block copolypeptides PNiPAM(n)(PBLG(x)-co-PBLLys(y))m, with a poly(N-isopropylacrylamide) block together with a random copolypeptide block, which was then deprotected with HBr/trifluoroacetic acid into the double hydrophilic block copolypeptides, PNiPAM(n)(PLG(x)-co-PLLys(y))m. Their block ratios and lengths, as well as the amino acid residue ratios in the random copolypeptide block are varied (n = 360, x = 0.4-0.5, y = 0.4-0.6, and m = 220-252). The secondary structures of the copolypeptides in aqueous solution at different pH conditions were examined. Phase transitions in aqueous solutions induced by both pH and temperature variation were investigated by (1)H NMR spectroscopy. The transitions induced by temperature were also explored by turbidity measurements using UV/vis spectroscopy for their lower critical aggregation temperature (LCAT) determination. Furthermore, these aggregation processes were followed by dynamic light scattering measurements.  相似文献   

19.
A simple and sensitive high-performance liquid chromatography (HPLC) method utilizing ultraviolet (UV) detection was developed for the determination of inosine and hypoxanthine in human plasma. For component separation, a monolithic C(18) column at a flow rate of 1.0 mL/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water pH 2.2, v/v) and methanol gradient was used. The method employed a one-step sample preparation utilizing centrifugal filtration with high component recoveries (approximately 98%) from plasma, which eliminated the need of an internal standard. The method demonstrated excellent linearity (0.25-5 microg/mL, R>0.9990) for both inosine and hypoxanthine with detection limits of 100 ng/mL. This simple and cost effective method was utilized to evaluate potential endogenous plasma biomarker(s), which may aid hospital emergency personnel in the early detection of acute cardiac ischemia in patients presenting with non-traumatic chest pain.  相似文献   

20.
A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its three metabolites O-desmethylvenlafaxine (ODV), N-desmethylvenlafaxine (NDV) and N,O-didesmethylvenlafaxine (DDV) in human plasma has been developed and validated. Estazolam was used as the internal standard. The compounds and internal standard were extracted from plasma by a liquid-liquid extraction. The HPLC separation of the analytes was performed on a Thermo BDS HYPERSIL C18 (250 mm x 4.6 mm, 5 microm, USA) column, using a gradient elution program with solvents constituted of water (ammonium acetate: 30 mmol/l, formic acid 2.6 mmol/l and trifluoroacetic acid 0.13 mmol/l) and acetonitrile (60:40, V/V) at a flow-rate of 1.0 ml/min. All of the analytes were eluted within 6 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and were detected in the selected ion recording (SIR) mode. Calibration curves in spiked whole blood were linear from 4.0-700 ng/ml, 2.0-900 ng/ml, 3.0-800 ng/ml and 2.0-700 ng/ml for VEN, ODV, NDV and DDV, respectively, all of them with coefficients of determination above 0.9991. The average extraction recoveries for all the four analytes were above 77%. The methodology recoveries were higher than 91%. The limits of detection were 0.4, 0.2, 0.3, and 0.2 ng/ml for VEN, ODV, NDV and DDV, respectively. The intra- and inter-day variation coefficients were less than 11%. The method is accurate, sensitive and reliable for the pharmacokinetic study of venlafaxine as well as therapeutic drug monitoring (TDM).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号