首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A solid-phase immunoadsorbent was prepared by insolubilization of antibody during precipitation with Na2SO4. The polyaldehyde macromolecule created by periodate oxidation of dextran (macrofixative) served as the insolubilizing, crosslinking agent. After appropriate fixation, the precipitate was stable to removal of the precipitating salt, to washing, and, to a large extent, to heating in the denaturing detergent, sodium dodecyl sulfate. Under proper conditions, the precipitate retained satisfactory antibody activity, although very high molecular weight antigens were apparently excluded from the internal active sites of the solid-phase matrix. This method provides the advantage of insolubilization of the primary antibody in a small volume; for analytical work, the entire precipitate, with bound antigen, may be quantitatively applied to a polyacrylamide gel (tube or slab) and electrophoresed without overloading by the binding antibody. This method might also be extended for use in immunoisolation procedures employing standard eluting agents, as well as insolubilization of proteins other than immunoglobulin.  相似文献   

2.
A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.  相似文献   

3.
This paper describes microextraction and gas chromatographic analysis of diazepam from human plasma. The method was based on immobilisation of 1.5 μl of 1-octanol on a polyacrylate-coated fiber designed for solid-phase microextraction. The solvent-modified fibre was used to extract diazepam from the samples. The plasma sample was pre-treated to release diazepam from the protein binding. The fibre was inserted into the modified plasma sample, adjusted to pH 5.5, an internal standard was added and the mixture was carefully stirred for 4 min. The fibre with the immobilised solvent and the enriched analytes was injected into the capillary gas chromatograph. The solvent and the extracted analytes were evaporated at 300°C in the split-splitless injection port of the gas chromatograph, separated on a methylsilicon capillary column and detected with a nitrogen-phosphorus detector. The method was shown to be reproducible with a detection limit of 0.10 nmol/ml in human plasma.  相似文献   

4.
Solid-phase microextraction (SPME) was investigated as a sample preparation method for assaying the neuroleptic drug clozapine in human plasma. A mixture of human plasma, water, loxapine (as internal standard) and aqueous NaOH was extracted with a 100-μm polydimethylsiloxane (PDMS) fiber (Supelco). Desorption of the fiber was performed in the injection port of a gas chromatograph at 260°C (HP 5890; 30 m×0.53 mm I.D., 1 μm film capillary; nitrogen–phosphorous selective detection). Fibers were used repeatedly in up to about 75 analyses. The recovery was found to be 3% for clozapine from plasma after 30 min of extraction. However, in spite of the low recovery, the analyte was well separated and the calibration was linear between 100 and 1000 ng/ml. The within-day and between-day precision was consistently about 8 to 15% at concentrations of 200 ng/ml to 1000 ng/ml. No interfering drug was found. The limit of detection was 30 ng/ml. The sample volume was 250 μl. The influence of the concentration of proteins, triglycerides and salt, i.e., changes in the matrix on the peak areas and peak-area ratios was studied. The method is not impaired by physiological changes in the composition of the matrix. Good agreement was found with a liquid–liquid extraction–gas–liquid chromatography (LLE–GLC) standard method and an on-line column-switching high-performance liquid chromatography (HPLC) method for patients’ samples and spiked samples, respectively. It is concluded that the method can be used in the therapeutic drug monitoring of clozapine because the therapeutic window of clozapine is from 350 to 600 ng/ml.  相似文献   

5.
This work evaluates the utility of solid-phase microextraction (SPME) in the analysis of amphetamines by liquid chromatography (LC) after chemical derivatization of the analytes. Two approaches have been tested and compared, SPME followed by on-fiber derivatization of the extracted amphetamines, and solution derivatization followed by SPME of the derivatives formed. Both methods have been applied to measure amphetamine (AP), methamphetamine (MA), and 3,4-methylenedioxymethamphetamine (MDMA), using the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) and carbowax-templated resin (CW-TR)-coated fibers. Data on the application of the proposed methods for the analysis of different kind of samples are presented. When analyzing aqueous solutions of the analytes, both approaches gave similar analytical performance, but the sensitivity attainable with the solution derivatization/SPME method was better. The efficiencies observed when processing spiked urine samples by the SPME/on-fiber derivatization approach were very low. This was because the extraction of matrix components into the fiber coating prevented the extraction of the reagent. In contrast, the efficiencies obtained for spiked urine samples by the solution derivatization/SPME approach were similar to those obtained for aqueous samples. Therefore, the later method would be the method of choice for the quantification of amphetamines in urine.  相似文献   

6.
A sensitive and automated method is described for determination of rifampicin in plasma samples for therapeutic drug monitoring by in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC). Important factors in the optimization of in-tube SPME are discussed, such as coating type, sample pH, sample draw/eject volume, number of draw/eject cycles, and draw/eject flow rate. Analyte pre-concentrated in the polyethylene glycol phase was directly transferred to the liquid chromatographic column by percolation of the mobile phase, without carryover. The method was linear over the 0.1-100 μg/mL range, with a linear coefficient value (r(2)) of 0.998. The inter-assay precision presented coefficient of variation ≤ 1.7%. The effectiveness and practicability of the proposed method are proven by analysis of plasma samples from ageing patients undergoing therapy with rifampicin.  相似文献   

7.
The parameters of the process of isolation, concentration, and gas chromatographic analysis of volatile organic compounds by solid-phase microextraction were optimized. With different amounts of a mixture of essential oils, the conditions of reproducibility of their determination were established based on the absolute values of the squares of chromatographic peaks obtained by capillary gas chromatography. It was found that the efficiency of the extraction of volatile compounds from gas phase by sorption on mixed polymer (consisting of polydimethylsiloxane and divinylbenzene) was significantly influenced by the structure of their molecules, while the sorption time and their content in the liquid phase influenced the significance of determination.  相似文献   

8.
Simultaneous determination of seven barbiturates in human whole blood and urine by combining direct immersion solid-phase microextraction (DI-SPME) with gas chromatography-mass spectrometry (GC-MS) is presented. The main parameters affecting the DI-SPME process, such as SPME fibers, salt additives, pHs, extraction temperatures and immersion times were optimized for simultaneous determination of the drugs. The extraction efficiencies were 0.0180-0.988 and 0.0156-2.76% for whole blood and urine, respectively. The regression equations of the drugs showed excellent linearity for both samples; the correlation coefficients (r(2)) were 0.994-0.999. The detection limits for whole blood were 0.05-1 microg x ml(-1), and those for urine 0.01-0.6 microg x ml(-1). Actual quantitation could be made for pentobarbital in whole blood and urine obtained from volunteers, who had been orally administered a therapeutic dose of the drug. The DI-SPME/GC-MS procedure for barbiturates established in this study is simple and sensitive enough to be adopted in the fields of clinical and forensic toxicology.  相似文献   

9.
Acetone is an important volatile disease marker. Due to its nature of activity and volatility, it is a difficult task to measure the concentration of acetone in biological samples with accuracy. In this paper, we developed a novel method for determination of trace amount acetone in human plasma by solid-phase microextraction technique with on-fiber derivatization. In this method, the poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber was used and O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine hydrochloride (PFBHA) was first loaded on the fiber. Acetone in plasma sample was agitated into headspace and extracted by solid-phase microextraction (SPME) fiber and subsequently derivatized with PFBHA on the fiber. Acetone oxime was analyzed by gas chromatography-mass spectrometry (GC-MS). Quantitative analysis of acetone in plasma was carried out by using external standard method. The SPME conditions (extraction temperature and time) and the method validation were studied. The present method was tested by determination of acetone in diabetes plasma and normal plasma. Acetone concentration in diabetes plasma was found to be higher than 1.8mM, while in normal plasma was lower than 0.017 mM. The results show that the present method is a potential tool for diagnosis of diabetes.  相似文献   

10.
Hexanal and heptanal in human blood have been regarded as potential biomarkers of lung cancer. Owing to their high volatilities and activities, it is difficult to accurately measure the two biomarkers. In the current work, headspace solid-phase microextraction (HS-SPME) with on-fiber derivatization technique was developed for quantitative analysis of hexanal and heptanal in human blood. In the proposed method, the two aldehydes in blood were headspace extracted by using a poly (dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber with O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine (PFBHA) at 60 degrees C for 8 min. The aldehyde oximes formed on the fiber were desorbed and analyzed by gas chromatography-mass spectrometry (GC-MS). The method validations including detection limit, recovery and precision were studied. It was found that the method provided low detection limits of 0.006 nM for hexanal and 0.005 nM for heptanal, recoveries from 89% to 95% and R.S.D. values less than 8.5%. The present method was applied to quantitative analysis of hexanal and heptanal in normal blood and lung cancer blood. Hexanal concentrations from 7.33 to 15.23 microM and heptanal concentrations from 2.47 to 9.23 microM were found in the lung cancer blood, while both hexanal and heptanal in the control blood were lower than 0.6 microM. This further demonstrated that hexanal and heptanal might be the biomarkers of lung cancer. The experimental results showed that GC-MS and HS-SPME with on-fiber derivatization is a simple, rapid, sensitive and solvent-free method for determination of in hexanal and heptanal human blood.  相似文献   

11.
A procedure for the determination of acetaldehyde, acetone, methanol, ethanol, 1-propanol and 2-propanol in blood was developed. Separation of analytes was carried out on DB-wax capillary column (l = 30 m, I.D. = 0.32 mm, dF = 0.5 microm) at 40 degrees C, hydrogen was used as a carrier gas (at 30 kPa) and FID as a detector. Quantification was performed with the use of 2-butanol as an internal standard. Headspace solid-phase microextraction was applied as the sample preparation technique. The usefulness of most commercially available fiber coatings was checked and 65 microm Carbowax/DVB proved most effective. Microextraction was carried out from the headspace at 60 degrees C for 10 min. The sample was stirred at 750 rpm. In order to improve the extraction efficiency of analytes, salting-out agents were also applied. Potassium carbonate turned out to be the most efficient. A 1.0-g amount of this salt and 0.1 ml of I.S. were added to 0.5 ml of sample. Validation of the worked-out method was performed. For each analyte, the limits of detection and quantification, linearity, working range, accuracy and precision were determined or tested.  相似文献   

12.
A method for the simultaneous determination of selegiline and its metabolite, desmethylselegiline, in human whole blood and urine is presented. The method, which combines a fiber-based headspace solid-phase microextraction (SPME) technique with gas chromatography-mass spectrometry (GC-MS), required optimization of various parameters (e.g., salt additives, extraction temperatures, extraction times and the extraction properties of the SPME fiber coatings). Pargyline was used as the internal standard. Extraction efficiencies for both selegiline and desmethylselegiline were 2.0-3.4% for whole blood, and 8.0-13.2% for urine. The regression equations for selegiline and desmethylselegiline extracted from whole blood were linear (r(2)=0.996 and 0.995) within the concentration ranges 0.1-10 and 0.2-20 ng/ml, respectively. For urine, the regression equations for selegiline and desmethylselegiline were linear (r(2)=0.999 and 0.998) within the concentration ranges 0.05-5.0 and 0.1-10 ng/ml, respectively. The limit of detection for selegiline and desmethylselegiline was 0.01-0.05 ng/ml for both samples. The lower and upper limits of quantification for each compound were 0.05-0.2 and 5-20 ng/ml, respectively. Intra- and inter-day coefficients of variation for selegiline and desmethylselegiline in both samples were not greater than 8.7 and 11.7%, respectively. The determination of selegiline and desmethylselegiline concentrations in Parkinson's disease patients undergoing continuous selegiline treatment is presented and is shown to validate the present methodology.  相似文献   

13.
A new approach using a simple solid-phase extraction technique has been developed for the determination of pyronaridine (PND), an antimalarial drug, in human plasma. After extraction with C18 solid-phase sorbent, PND was analyzed using a reverse phase chromatographic method with fluorescence detection (at lambda(ex)=267 nm and lambda(em)=443 nm). The mean extraction recovery for PND was 95.2%. The coefficient of variation for intra-assay precision, inter-assay precision and accuracy was less than 10%. The quantification limit with fluorescence detection was 0.010 microg/mL plasma. The method described herein has several advantages over other published methods since it is easy to perform and rapid. It also permits reducing both, solvent use and sample preparation time. The method has been used successfully to assay plasma samples from clinical pharmacokinetic studies.  相似文献   

14.
This study investigated the feasibility of applying solid-phase microextraction (SPME) combined with gas chromatography–mass spectrometry to analyze chlorophenols in urine. The SPME experimental procedures to extract chlorophenols in urine were optimized with a polar polyacrylate coated fiber at pH 1, extraction time for 50 min and desorption in GC injector at 290°C for 2 min. The linearity was obtained with a precision below 10% R.S.D. for the studied chlorophenols in a wide range from 0.1 to 100 μg/l. In addition, sample extraction by SPME was used to estimate the detection limits of chlorophenols in urine, with selected ion monitoring of GC–MS operated in the electron impact mode and negative chemical ionization mode. Detection limits were obtained at the low ng/l levels. The application of the methods to the determination of chlorophenols in real samples was tested by analyzing urine samples of sawmill workers. The chlorophenols were found in workers, the urinary concentration ranging from 0.02 μg/l (PCP) to 1.56 μg/l (2,4-DCP) depending on chlorophenols. The results show that trace chlorophenols have been detected with SPME–GC–MS in the workers of sawmill where chlorophenol-containing anti-stain agents had been previously used.  相似文献   

15.
A simple, rapid and sensitive method for determination of rivastigmine in plasma samples was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography with mass spectrometry (GC-MS). The optimum conditions for the SPME procedure were: headspace extraction on a 65-microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber; 0.5 ml of plasma modified with 1.0 ml of sodium hydroxide-sodium carbonate solution (0.7 M:0.5M); extraction temperature of 100 degrees C, with stirring at 2000 rpm for 30 min. The calibration curve showed linearity in the range from 0.2 to 80 ng/ml with regression coefficient corresponding to 0.9965 and coefficient of the variation of the points of the calibration curve lower than 10%. The quantification limit for rivastigmine in plasma was 0.2 ng/ml. The method was applied to determination of rivastigmine in canine plasma samples from animals after a single oral administration.  相似文献   

16.
A novel solid-phase microextraction (SPME) method was developed for isolation of dextromethorphan (DM) and its main metabolite dextrorphan (DP) from human plasma followed by GC-MS determination. Three different polymers, poly(dimethylsiloxane) (PDMS), poly(ethylenepropyleneglycol) monobutyl ether (Ucon) and polyethylene glycol (PEG) were synthesized as coated fibers using sol-gel methodologies. DP was converted to its acetyl-derivative prior to extraction and subsequent determination. The porosity of coated fibers was examined by SEM technique. Effects of different parameters such as fiber coating type, extraction mode, agitation method, sample volume, extraction time, and desorption condition, were investigated and optimized. The method is rapid, simple, easy and inexpensive and offers high sensitivity and reproducibility. The limits of detection are 0.010 and 0.015 ng/ml for DM and DP, respectively. The precisions for both analytes are below 5% (n=5). The correlation coefficient was satisfactory (r(2)>0.99) for both DM and DP. Linear ranges were obtained from 0.03 ng/ml to 2 microg/ml for DM and from 0.05 ng/ml to 2 microg/ml for DP.  相似文献   

17.
We developed a new sample preparation method for profiling organic acids in urine by GC or GC–MS. The method includes derivatisation of the organic acids directly in the aqueous urine using trimethyloxonium tetrafluoroborate as a methylating agent, extraction of the organic acid methyl esters from the urine by solid-phase microextraction, using a polyacrylate fiber with a thickness of 85 μm and transfer of the methyl esters into the GC or the GC–MS instrument. Desorption of the analytes takes place in the heated injection port. The proposed sample preparation is very simple. There is no need for any evaporation step and for the use of an organic solvent. The risk of contamination and the loss of analytes are minimized. The total sample preparation time prior to GC or GC–MS analysis is about 40 min, and therefore more rapid than other sample preparation procedures. The urinary organic acids are well separated by GC and 29 substances are identified by GC–MS.  相似文献   

18.
A library of 80 analogues of the antibacterial compound mureidomycin was prepared using solid-phase chemistry techniques.  相似文献   

19.
Reaction rates have been measured for the production of selected bradykinins, angiotensins, and endorphins by solid-phase synthesis. Reactor liquid concentrations are monitored by using a UV detector and flow cell. Experimentation has been limited to low excesses of the t-Boc amino symmetrical anhydride. More than 500 attachments have been monitored. Most data obtained from resins with 1% cross-linking show second-order behavior with reaction rate constants between 0.5 and 8 L/(mol.s). The reaction rate is affected by chemical structures of both the attached amino symmetrical anhydride and the anchored amino terminus on the peptide fragment. Increasing reaction temperature and initial solution concentrations promotes reaction rate. The structure of the polymer support affects not only the reaction rate but also the observed reaction kinetics.  相似文献   

20.
In this study, a solid-phase microextraction (SPME) method based on poly(acrylate)-coated fibres has been developed for detection and quantification of chlorinated bisphenol A in human plasma due to the need for an assessment of human exposure to them. After desorption of the analytes for 7 min at 300 degrees C, they were directly derivatized in the GC injector port by injection of 2 microL of diluted bis(trimethylsilyl)trifluoroacetamide (BSTFA). The formation of trimethylsilylate derivatives improves the selectivity, sensitivity and performance of the chromatographic properties obtained when the analytes are directly separated. Quantification was carried out using single-ion monitoring (SIM). The respective chloroderivative molecular ions appear at 406, 440, 474 and 508 m/z; whereas the base peaks corresponding to a loss of a methyl group in all cases appear at 391, 425, 459 and 493 m/z for mono-, di-, tri- and tetrabisphenol A, respectively. Deuterated bisphenol A (BPA-d16) was used as an internal standard. The method was applied to the determination of Cl-BPA, Cl2-BPA, Cl3-BPA and Cl4-BPA at very low concentration levels in plasma. Recovery efficiencies were close to 100% in all cases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号