首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Motion of the wrist bones is complicated and difficult to measure. Noninvasive measurement of carpal kinematics using medical images has become popular This technique is difficult and most investigators employ custom software. The objective of this paper is to describe a validated methodology for measuring carpal kinematics from computed tomography (CT) scans using commercial software. Four cadaveric wrists were CT imaged in neutral, full flexion, and full extension. A registration block was attached to the distal radius and used to align the data sets from each position. From the CT data, triangulated surface models of the radius, lunate, and capitate bones were generated using commercial software. The surface models from each wrist position were read into engineering design software that was used to calculate the centroid (position) and principal mass moments of inertia (orientation) of (1) the capitate and lunate relative to the fixed radius and (2) the capitate relative to the lunate. These data were used to calculate the helical axis kinematics for the motions from neutral to extension and neutral to flexion. The kinematics were plotted in three dimensions using a data visualization software package. The accuracy of the method was quantified in a separate set of experiments in which an isolated capitate bone was subjected to two different known rotation/translation motions for ten trials each. For comparison to in vivo techniques, the error in distal radius surface matching was determined using the block technique as a gold standard. The motion that the lunate and capitate underwent was half that of the overall wrist flexion-extension range of motion. Individually, the capitate relative to the lunate and the lunate relative to the radius generally flexed or extended about 30 deg, while the entire wrist (capitate relative to radius) typically flexed or extended about 60 deg. Helical axis translations were small, ranging from 0.6 mm to 1.8 mm across all motions. The accuracy of the method was found to be within 1.4 mm and 0.5 deg (95% confidence intervals). The mean error in distal radius surface matching was 2.4 mm and 1.2 deg compared to the use of a registration block. Carpal kinematics measured using the described methodology were accurate, reproducible, and similar to findings of previous investigators. The use of commercially available software should broaden the access of researchers interested in measuring carpal kinematics using medical imaging.  相似文献   

2.
3.
A novel computational model of the wrist that predicts carpal bone motion was developed in order to investigate the complex kinematics of the human wrist.This rigid body spring model (RBSM) of the wrist was built using surface models of the eight carpal bones, the bases of the five metacarpal bones, and the distal parts of the ulna and radius, all obtained from computed tomography (CT) scans of a cadaver upper limb. Elastic contact conditions between the rigid bodies modeled the influence of the cartilage layers, and ligamentous structures were constructed using nonlinear, tension-only spring elements. Motion of the wrist was simulated by applying forces to the tendons of the five main wrist muscles modeled.Three wrist motions were simulated: extension, ulnar deviation and radial deviation. The model was tested and tuned by comparing the simulated displacement and orientation of the carpal bones with previously obtained CT-scans of the same cadaver arm in deviated (45°ulnar and 15°radial), and extended (57°) wrist positions. Simulation results for the scaphoid, lunate, capitate, hamate and triquetrum are presented here and provide credible prediction of carpal bone movement. These are the first reported results of such a model. They indicate promise that this model will assist in future wrist kinematics investigations. However, further optimization and validation are required to define and guarantee the validity of results.  相似文献   

4.
It has previously been shown that the articulation of the scaphotrapezio-trapezoidal (STT) joint can be modeled such that the trapezoid and trapezium are tightly linked and move together on a single path relative to the scaphoid during all directions of wrist motion. The simplicity of such a model is fascinating, but it leaves unanswered why two distinct carpal bones would have a mutually articulating surface if there were no motion between them, and how such a simplistic model of STT joint motion translates into the more complex global carpal motion. We performed an in vivo analysis of the trapezoids and trapeziums of 10 subjects (20 wrists) using a markerless bone registration technique. In particular, we analyzed the centroid spacing, centroid displacements, kinematics, and postures of the trapezoid and trapezium relative to the scaphoid. We found that, on a gross level, the in vivo STT motion was consistent with that reported in vitro. In addition, we found that the magnitude of trapezoid and trapezium motion was dependent upon the direction of wrist motion. However, we also found that when small rotations and displacements are considered there were small but statistically significant relative motions between the trapezoid and trapezium (0.4 mm in maximum flexion, 0.3 mm in radial deviation and at least 10 degrees in flexion extension and ulnar deviation) as well as slight off-path rotations. The results of this study indicate that the STT joint should be considered a mobile joint with motions more complex than previously appreciated.  相似文献   

5.
An in-vivo approach to the measurement of three-dimensional motion patterns of carpal bones in the wrist may have future diagnostic applications, particularly for ligament injuries of the wrist. Static methods to measure carpal kinematics in-vivo only provide an approximation of the true kinematics of the carpal bones. This study is aimed at finding the difference between dynamically and statically acquired carpal kinematics.For eight healthy subjects, static and a dynamic measurements of the carpal kinematics were performed for a flexion–extension and a radio–ulnar deviation movement. Dynamic scans were acquired by using a four-dimensional X-ray imaging system during an imposed cyclic motion. To assess static kinematics of the wrists, three-dimensional rotational X-ray scans were acquired during step-wise flexion–extension and radio–ulnar deviation. The helical axis rotations and the rotation components. i.e. flexion–extension, radio–ulnar deviation and pro–supination were the primary parameters. Linear mixed model statistical analysis was used to determine the significance of the difference between the dynamically and statically acquired rotations of the carpal bones.Small and in most cases negligible differences were observed between the dynamic motion and the step-wise static motion of the carpal bones. The conclusion is that in the case of individuals without any pathology of the wrist, carpal kinematics can be studied either dynamically or statically. Further research is required to investigate the dynamic in-vivo carpal kinematics in patients with dynamic wrist problems.  相似文献   

6.
The use of registration techniques to determine motion transformations noninvasively has become more widespread with the increased availability of the necessary software. In this study, three surface registration techniques were used to generate carpal bone kinematic results from a single cadaveric wrist specimen. Surface contours were extracted from specimen computed tomography volume images of the forearm, carpal, and metacarpal bones in four arbitrary positions. Kinematic results from each of three registration techniques were compared with results derived from multiple spherical markers fixed to the specimen. Kinematic accuracy was found to depend on the registration method and bone size and shape. In general, rotation errors of the capitate and scaphoid were less than 0.5 deg for all three techniques. Rotation errors for the other bones were generally less than 2 deg, although error for the trapezoid was greater than 2 deg in one technique. Translation errors of the bones were generally less than 1 mm, although errors of the trapezoid and trapezium were greater than 1 mm for two techniques. Tradeoffs existed in each registration method between image processing time and overall kinematic accuracy. Markerless bone registration (MBR) can provide accurate measurements of carpal kinematics and can be used to study the noninvasive, three-dimensional in vivo kinematics of the wrist and other skeletal joints.  相似文献   

7.
Measurements of in-vitro carpal kinematics of the wrist provide valuable biomechanical data. Tendon loading is often applied during cadaver experiments to simulate natural stabilizing joint compression in the wrist joint. The purpose of this study was to investigate the effect of tendon loading on carpal kinematics in-vitro.A cyclic movement was imposed on 7 cadaveric forearms while the carpal kinematics were acquired by a 4-dimensional rotational X-ray imaging system. The extensor- and flexor tendons were loaded with constant force springs of 50 N, respectively. The measurements were repeated without a load on the tendons. The effect of loading on the kinematics was tested statistically by using a linear mixed model.During flexion and extension, the proximal carpal bones were more extended with tendon loading. The lunate was on the average 2.0° (p=0.012) more extended. With tendon loading the distal carpal bones were more ulnary deviated at each angle of wrist motion. The capitate was on the average 2.4° (p=0.004) more ulnary deviated.During radioulnar deviation, the proximal carpal bones were more radially deviated with the lunate 0.7° more into radial deviation with tendon loading (p<0.001). Conversely, the bones of distal row were more flexed and supinated with the capitate 1.5° more into flexion (p=0.025) and 1.0° more into supination (p=0.011).In conclusion, the application of a constant load onto the flexor and extensor tendons in cadaver experiments has a small but statistically significant effect on the carpal kinematics during flexion–extension and radioulnar deviation.  相似文献   

8.
Present data on carpal kinematics and carpal ligament behaviour are limited to flexion and deviation movements of the hand. These motions do not represent all the wrist-joint motions which are important for the activities of daily living. The goal of this project was to obtain insight into carpal kinematics and carpal ligament behaviour during motions of the hand covering the full range of motion of the wrist joint.

The carpals and the ligaments of four wrist-joint specimens were provided with radiopaque markers. These joints were subjected to Röntgenstereophotogrammetric experimentation in a large number of hand positions to determine carpal positions and ligament lengths. The movements of the carpal bones were described by means of finite helical axes (FHA).

It was found that the movements of the carpals in the distal row closely resemble those of the hand. Conversely, the motions of the carpals of the proximal row appeared not to be directly proportional to the hand motions and exhibited clear out-of-plane movements. Furthermore, it could be shown that movements of the hand into the ulnodorsal quadrant of the full range of hand motion corresponds to larger helical rotations and translations for most of the carpals than when the hand was moved into any other quadrant. The maximal ligament length changes determined did not exceed the length changes reported for pure flexion and pure deviation movements of the hand.  相似文献   


9.
Most E  Axe J  Rubash H  Li G 《Journal of biomechanics》2004,37(11):1743-1748
Various flexion axes have been used in the literature to describe knee joint kinematics. This study measured the passive knee kinematics of six cadaveric human knee specimens using two widely accepted flexion axes; transepicondylar axis and the geometric center axis. These two axes were found to form an angle of 4.0 degrees +/- 0.8 degrees. The tibial rotation calculated using the transepicondylar axis was significantly different than the rotation obtained using the geometric center axis for the same knee motion. At 90 degrees of flexion, the tibial rotation obtained using the transepicondylar axis was 4.8 degrees +/- 9.4 degrees whereas the rotation recorded using the geometric center axis at the same flexion angle was 13.8 degrees +/- 10.2 degrees. At 150 degrees of knee flexion, the rotations obtained from the transepicondylar and the geometric center axes were 7.2 degrees +/- 5.7 degrees and 19.9 degrees +/- 6.9 degrees, respectively. The data suggest that a clear definition of the flexion axis is necessary when reporting knee joint kinematics.  相似文献   

10.
Kuo LC  Su FC  Chiu HY  Yu CY 《Journal of biomechanics》2002,35(11):1499-1506
While several different methods have been used to measure hand kinematics, fluoroscopy is generally considered to be the most accurate. Recently, video-based motion analysis has been developed for the measurement of joint kinematics. This method is versatile, easy to use, and can measure motions dynamically. Surface markers are most commonly used in the video-based motion systems. However, whether the surface markers placed on the thumb accurately represent the true kinematics of the underlying bony segment is questionable.In this study, the feasibility of surface markers to represent thumb kinematics was investigated by fluoroscopy. Both the positions of surface markers and bony landmarks were simultaneous recorded and then digitized. The Ra(2) values comparing the angular changes of the thumb interphalangeal, metacarpal and carpometacarpal joints derived using the surface markers or bony landmarks were 0.9986, 0.9730 and 0.9186 in the flexion/extension plane respectively, 0.8837, 0.9697 and 0.8775 in the abduction/adduction plane; and 0.9884, 0.9643 and 0.9431 in the opposition plane. The ranges, mean and standard deviation of the absolute differences between calculated angles of different marker sets were also compared. These data revealed that the similarities of the two different marker techniques throughout the motion cycle were high. The differences between the two methods were also within clinically allowable range of +/-5 degrees. It is concluded that the application of the video-based motion analysis system with surface markers to thumb kinematics is warranted.  相似文献   

11.
Accurately assessing the dynamic kinematics of the skeletal wrist could advance our understanding of the normal and pathological wrist. Biplane videoradiography (BVR) has allowed investigators to study dynamic activities in the knee, hip, and shoulder joint; however, currently, BVR has not been utilized for the wrist joint because of the challenges associated with imaging multiple overlapping bones. Therefore, our aim was to develop a BVR procedure and to quantify its accuracy for evaluation of wrist kinematics. BVR was performed on six cadaveric forearms for one neutral static and six dynamic tasks, including flexion-extension, radial-ulnar deviation, circumduction, pronation, supination, and hammering. Optical motion capture (OMC) served as the gold standard for assessing accuracy. We propose a feedforward tracking methodology, which uses a combined model of metacarpals (second and third) for initialization of the third metacarpal (MC3). BVR-calculated kinematic parameters were found to be consistent with the OMC-calculated parameters, and the BVR/OMC agreement had submillimeter and sub-degree biases in tracking individual bones as well as the overall joint’s rotation and translation. All dynamic tasks (except pronation task) showed a limit of agreement within 1.5° for overall rotation, and within 1.3 mm for overall translations. Pronation task had a 2.1° and 1.4 mm limit of agreement for rotation and translation measurement. The poorest precision was achieved in calculating the pronation-supination angle, and radial-ulnar and volar-dorsal translational components, although they were sub-degree and submillimeter. The methodology described herein may assist those interested in examining the complexities of skeletal wrist function during dynamic tasks.  相似文献   

12.
The cercopithecoid wrist joint differs from the wrist joints of hominoids in several ways. The distal ulna, the distal radius, the pisiform, the triquetrum, the hamate, and the base of the fifth metacarpal are on the one hand remarkably alike among cercopithecoid genera, and on the other remarkably distinct from homologous bones in the Hominoidea. Functionally, the triquetrum and the pisiform, in conjuction with the ulnar styloid process, check the proximal carpal row during ulnar deviation, and are possibly important in stabilizing the wrist during dorsiflexion as well. The head of the ulna almost certainly betokens a range of radioulnar supination in cercopithecoids that is substantially less than is to be found in any of the hominoid genera. The articulation between the hamate bone and the base of the fifth metacarpal allows for considerable dorsiflexion in the Cercopithecoidea; this potential was not evidenct in any of the hominoids examined. Behaviorally, the cercopithecoid wrist can most profitably be viewed as an adaptation for a quadrupedal life style involving dorsiflexion of the wrist and palmigrade/digitigrade substrate contact. The hominoid wrist joint is not adapted for such a behavioral potential.  相似文献   

13.
In this paper, we propose a method to estimate the parameters of a double hinge model of the trapeziometacarpal joint (TMC) by MRI-based motion analysis. The model includes two non-orthogonal and non-intersecting rotation axes accounting for flexion–extension (F–E) and adduction–abduction (A–A). We evaluated the quality of the estimated model parameters in the prediction of the relative motion of the first metacarpal bone with respect to the trapezium. As a result, we obtained that: (a) the estimated location and orientation of the F–E and A–A axes were in agreement with previous in vitro studies, (b) the motion of the first metacarpal predicted by the 2 degrees of freedom (2DoF) model exhibits a maximum surface distance error in the range of about 2 mm and (c) four thumb postures at the boundary of the TMC range of motion are sufficient to provide a good estimation of the 2DoF TMC kinematic model and good reproducibility (~1.7 mm) of the real thumb motion at TMC level.  相似文献   

14.
Understanding the kinematics of the carpus is essential to the understanding and treatment of wrist pathologies. However, many of the previous techniques presented are limited by non-functional motion or the interpolation of points from static images at different postures. We present a method that has the capability of replicating the kinematics of the wrist during activities of daily living using a unique mechanical testing system. To quantify the kinematics of the carpal bones, we used bone pin-mounted markers and optical motion capture methods. In this paper, we present a hammering motion as an example of an activity of daily living. However, the method can be applied to a wide variety of movements. Our method showed good accuracy (1.0–2.6°) of in vivo movement reproduction in our ex vivo model. Most carpal motion during wrist flexion–extension occurs at the radiocarpal level while in ulnar deviation the motion is more equally shared between radiocarpal and midcarpal joints, and in radial deviation the motion happens mainly at the midcarpal joint. For all rotations, there was more rotation of the midcarpal row relative to the lunate than relative to the scaphoid or triquetrum. For the functional motion studied (hammering), there was more midcarpal motion in wrist extension compared to pure wrist extension while radioulnar deviation patterns were similar to those observed in pure wrist radioulnar deviation. Finally, it was found that for the amplitudes studied the amount of carpal rotations was proportional to global wrist rotations.  相似文献   

15.
The measurement of wrist passive ranges of motion (ROMs) can provide insight into improvements and allow for effective monitoring during a rehabilitation program. Compared with conventional methods, this study proposed a new robotic assessment technique for measuring passive ROMs of the wrist. The robotic system has a reconfigurable handle structure that allows for multi-dimensional applications of wrist motions. The assessment reliability of this robotic system was analysed on 11 subjects for measuring wrist extension/flexion and radial/ulnar deviation. Preliminary data demonstrated its potential with intraclass correlation coefficient (ICC2,1) all greater than 0.857 and standard error of measurement (SEM) less than 3.38°. Future work will focus on the standardization of the assessment protocol of this robotic system for assessment purposes, paving the way for its clinical application.  相似文献   

16.
The purpose of this study was to compare passive to active testing on the kinematics of the elbow and forearm using a load-controlled testing apparatus that simulates muscle loading. Ten fresh-frozen upper extremities were tested. Active control was achieved by employing computer-controlled pneumatic actuators attached to the tendons of the brachialis, biceps, triceps, brachioradialis and pronator teres. Motion of the radius and ulna relative to the humerus was measured with an electromagnetic tracking system. Active elbow flexion produced more repeatable motion of the radius and ulna than when tested passively (p<0.05). The decrease in variability, as determined from the standard deviation of five successive trials in each specimen, was 76.5 and 58.0% for the varus-valgus and internal-external motions respectively (of the ulna relative to the humerus). The variability in flexion during simulated active forearm supination was 30.6% less than during passive testing. Thus under passive control, in the absence of stability provided by muscular loading across the joint, these uncontrolled motions produce increased variability amongst trials. The smooth and repeatable motions resulting from active control, that probably model more closely the physiologic state, appear to be beneficial in the evaluation of unconstrained kinematics of the intact elbow and forearm.  相似文献   

17.
While several different methods have been used to measure carpal kinematics, biplanar radiography is generally considered to be the most accurate and popular one. However, biplanar radiography is tedious and so only pseudo-dynamic kinematics can be measured. Recently, magnetic tracking system has been developed for the measurement of joint kinematics which is versatile and easy to use and so the possibility of measuring motions dynamically. In this study, the capability of a magnetic tracking device to accurately measure carpal kinematics was investigated by comparing it with biplanar radiography. The kinematics of the third metacarpal, scaphoid, and lunate in five fresh cadaveric specimens were measured using both methods as the wrists were placed in eight positions. The finite screw rotation of each bone with respect to the distal radius during selecting the seven wrist motions was calculated for both measuring techniques and compared. In general, the kinematics for all three bones measured by using either magnetic tracking device or biplanar radiography was identical and showed no statistical difference. The averaged differences ranged from 0.0 to 2.0°. These differences were due to the potential effect of the weight of the sensors and the interference of the attaching rod to the surrounding tissue. It is concluded that the application of the magnetic tracking device to carpal kinematics is warranted, if proper technical procedures as suggested are followed.  相似文献   

18.
Wrist rotations about one wrist axis (e.g. flexion/extension) can affect the strength about another wrist axis (e.g. radial/ulnar deviation). This study used a musculoskeletal model of the distal upper extremity, and an optimization approach, to quantify the interaction effects of wrist flexion/extension (FE), radial/ulnar deviation (RUD) and forearm pronation/supination (PS) on wrist strength. Regression equations were developed to predict the relative changes in strength from the neutral posture, so that the changes in strength, due to complex and interacting wrist and forearm rotation postures, can be incorporated within future ergonomics assessments of wrist strength.  相似文献   

19.
Helical axes of passive knee joint motions   总被引:6,自引:0,他引:6  
  相似文献   

20.
A digital database of wrist bone anatomy and carpal kinematics   总被引:2,自引:0,他引:2  
The skeletal wrist consists of eight small, intricately shaped carpal bones. The motion of these bones is complex, occurs in three dimensions, and remains incompletely defined. Our previous efforts have been focused on determining the in vivo three-dimensional (3-D) kinematics of the normal and abnormal carpus. In so doing we have developed an extensive database of carpal bone anatomy and kinematics from a large number of healthy subjects. The purpose of this paper is to describe that database and to make it available to other researchers. CT volume images of both wrists from 30 healthy volunteers (15 males and 15 females) were acquired in multiple wrist positions throughout the normal range of wrist motion. The outer cortical surfaces of the carpal bones, radius and ulna, and proximal metacarpals were segmented and the 3-D motion of each bone was calculated for each wrist position. The database was constructed to include high-resolution surface models, measures of bone volume and shape, and the 3-D kinematics of each segmented bone. The database does not include soft tissues of the wrist. While there are numerous digital anatomical databases, this one is unique in that it includes a large number of subjects and it contains in vivo kinematic data as well as the bony anatomy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号