首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Coronary artery anomalies and aortic valve morphology in the Syrian hamster   总被引:2,自引:0,他引:2  
In the Syrian hamster, anomalies in the origin of the left coronary artery are significantly associated with the bicuspid condition of the aortic valve. In this species, bicuspid aortic valves are expressions of a trait, the variation of which takes the form of a phenotypic continuum, ranging from a tricuspid aortic valve with no commissural fusion to a bicuspid aortic valve with the aortic sinuses located in ventrodorsal orientation and devoid of any raphe. The intermediate stages of the continuum are represented by tricuspid aortic valves with a more or less extensive fusion of the ventral commissure and bicuspid aortic valves with a more or less developed raphe located in the ventral aortic sinus. The present study was designed to decide whether there is a gap between tricuspid and bicuspid aortic valves regarding the incidence of coronary artery anomalies, or whether this incidence varies according to the different tricuspid and bicuspid morphotypes of the continuum. The study was carried out in Syrian hamsters belonging to a single inbred family with a high incidence of tricuspid aortic valves with fusion of the ventral commissure, bicuspid aortic valves, and anomalies in the origin of the left coronary artery, i.e. single right coronary artery ostium in aorta, anomalous origin of the left coronary artery from the pulmonary artery, and anomalous origin of the left coronary artery from the dorsal aortic sinus. The specimens were examined by means of a stereomicroscope and, in several cases, scanning electron microscopy was also used. The relationships between anomalous coronary artery patterns and aortic valve morphologies were tested using a logistic regression model. The results obtained indicate that there is no discontinuity between tricuspid and bicuspid aortic valves regarding the incidence of coronary artery anomalies. The probability of occurrence of anomalous coronary artery patterns increases continuously according to the deviation degree of the aortic valve from its normal (tricuspid) design. The present findings suggest that in the Syrian hamster, the morphogenetic mechanisms involved in the formation of congenital anomalous aortic valves and anomalies in the origin of the left coronary artery, respectively, are strongly related from an aetiological viewpoint.  相似文献   

2.
An in vitro comparative study of St. Jude (SJ) and Edwards-Duromedics (DM) Bileaflet valves was performed under steady and physiological pulsatile flow conditions in an axisymmetric chamber using Laser Doppler Anemometry (LDA). LDA measurements were conducted in two different orientations; in the first orientation, the LDA traverse was perpendicular and, in the second orientation, parallel to the tilt axis of the leaflets. The axial velocities were measured in both orientations at two different locations distal to the valves. The velocity profiles at peak systole show the presence of stronger vortex in the sinus region for flow past SJ valve in the first orientation compared to the DM valve. Velocity profile distal to the SJ valve in second orientation was relatively flat where as for the DM valve, a jet-like flow was present. The differences found in the velocity profiles between the two valves can be attributed to the differences in geometry with thicker leaflets, smaller angle of leaflets opening and the presence of the leaflet curvature for the DM valve. The results obtained in this study do not show any fluid dynamic advantages due to the curved leaflet geometry of the DM valve.  相似文献   

3.
Regions of turbulence downstream of bioprosthetic heart valves may cause damage to blood components, vessel wall as well as to aortic valve leaflets. Stentless aortic heart valves are known to posses several hemodynamic benefits such as larger effective orifice areas, lower aortic transvalvular pressure difference and faster left ventricular mass regression compared with their stented counterpart. Whether this is reflected by diminished turbulence formation, remains to be shown. We implanted either stented pericardial valve prostheses (Mitroflow), stentless valve prostheses (Solo or Toronto SPV) in pigs or they preserved their native valves. Following surgery, blood velocity was measured in the cross sectional area downstream of the valves using 10MHz ultrasonic probes connected to a dedicated pulsed Doppler equipment. As a measure of turbulence, Reynolds normal stress (RNS) was calculated at two different blood pressures (baseline and 50% increase). We found no difference in maximum RNS measurements between any of the investigated valve groups. The native valve had significantly lower mean RNS values than the Mitroflow (p=0.004), Toronto SPV (p=0.008) and Solo valve (p=0.02). There were no statistically significant differences between the artificial valve groups (p=0.3). The mean RNS was significantly larger when increasing blood pressure (p=0.0006). We, thus, found no advantages for the stentless aortic valves compared with stented prosthesis in terms of lower maximum or mean RNS values. Native valves have a significantly lower mean RNS value than all investigated bioprostheses.  相似文献   

4.
A pair of finite element models has been employed to study the interaction of blood flow with the operation of the aortic valve. A three-dimensional model of the left ventricle with applied wall displacements has been used to generate data for the spatially and time-varying blood velocity profile across the aortic aperture. These data have been used as the inlet loading conditions in a three-dimensional model of the aortic valve and its surrounding structures. Both models involve fluid-structure interaction and simulate the cardiac cycle as a dynamic event. Confidence in the models was obtained by comparison with data obtained in a pulse duplicator. The results show a circulatory flow being generated in the ventricle which produces a substantially axial flow through the aortic aperture. The aortic valve behaves in an essentially symmetric way under the action of this flow, so that the pressure difference across the leaflets is approximately uniform. This work supports the use of spatially uniform but temporally variable pressure distributions across the leaflets in dry or structural models of aortic valves. The study is a major advance through its use of truly three-dimensional geometry, spatially non-uniform loading conditions for the valve leaflets and the successful modelling of progressive contact of the leaflets in a fluid environment.  相似文献   

5.
There is strong evidence that failure of bioprosthetic and synthetic valves occurs as a consequence of high tensile and bending stresses, acting on the leaflets during opening and closing. In stented prostheses, whether synthetic or biological, the absence of contraction of the aortic base causes the leaflets to be subjected to an unphysiological degree of flexure, which is also related to calcification. However, a stentless synthetic valve, which has a flexible aorta base, can be a good alternative for stented synthetic valves. Moreover, fiber-reinforcement is assumed to lead to a decrease of tears and perforation as a result of reduced stresses in the weaker parts of the leaflets in their closed configuration. The manufacturing method for a stentless, fiber-reinforced, synthetic valve is presented. Prototypes are tested in a pulse duplicator system. The results show that the mean systolic pressure difference is very low, while the high regurgitation (up to 26%) is probably caused by a too small coaptation area of the leaflets.  相似文献   

6.
To explore reasons for a high accumulation of Ca and P occurring in the coronary artery of Thai with aging, the authors investigated age-related changes of elements in the coronary artery, ascending aorta near the heart, and cardiac valves in single individuals, and the relationships in the elements between the coronary artery and either the ascending aorta or cardiac valves. After an ordinary dissection by medical students at Chiang Mai University was finished, the anterior descending arteries of the left coronary artery, ascending aortas, mitral valves, and aortic valves were resected from the subjects. The subjects consisted of 17 men and 9 women, ranging in age from 46 to 76 yr. The element content was analyzed by inductively coupled plasma-atomic emission spectrometry. The average content of Ca and P was the highest in the coronary artery and decreased in the order aortic valve, ascending aorta, and mitral valve. The Ca, P, and Mg content increased in the coronary artery in the fifties and in the ascending aorta, aortic valve, and mitral valve in the sixties. It should be noted that the accumulation of Ca, P, and Mg occurred earlier in the coronary artery than in the ascending aorta, aortic valve, and mitral valve. It was found that with respect to the Ca, P, Mg, and Na contents, the coronary artery correlated well with both the aortic valve and ascending aorta, especially with the aortic valve, but it did not correlate with the mitral valves. This finding suggests that the accumulation of Ca, P, Mg, and Na occurs in the coronary artery together with the aortic valve and ascending aorta, but not together with the mitral valve. Because regarding the accumulation of Ca, P, and Mg, the ascending aorta and aortic valve are preceded by the coronary artery, it is unlikely that the accumulation of Ca, P, and Mg spreads from the ascending aorta or aortic valve to the coronary artery.  相似文献   

7.
Aortic valve (AV) calcification is a highly prevalent disease with serious impact on mortality and morbidity. Although exact causes and mechanisms of AV calcification are unclear, previous studies suggest that mechanical forces play a role. Since calcium deposits occur almost exclusively on the aortic surfaces of AV leaflets, it has been hypothesized that adverse patterns of fluid shear stress on the aortic surface of AV leaflets promote calcification. The current study characterizes AV leaflet aortic surface fluid shear stresses using Laser Doppler velocimetry and an in vitro pulsatile flow loop. The valve model used was a native porcine valve mounted on a suturing ring and preserved using 0.15% glutaraldehyde solution. This valve model was inserted in a mounting chamber with sinus geometries, which is made of clear acrylic to provide optical access for measurements. To understand the effects of hemodynamics on fluid shear stress, shear stress was measured across a range of conditions: varying stroke volumes at the same heart rate and varying heart rates at the same stroke volume. Systolic shear stress magnitude was found to be much higher than diastolic shear stress magnitude due to the stronger flow in the sinuses during systole, reaching up to 20 dyn/cm2 at mid-systole. Upon increasing stroke volume, fluid shear stresses increased due to stronger sinus fluid motion. Upon increasing heart rate, fluid shear stresses decreased due to reduced systolic duration that restricted the formation of strong sinus flow. Significant changes in the shear stress waveform were observed at 90 beats/min, most likely due to altered leaflet dynamics at this higher heart rate. Overall, this study represents the most well-resolved shear stress measurements to date across a range of conditions on the aortic side of the AV. The data presented can be used for further investigation to understand AV biological response to shear stresses.  相似文献   

8.
The stress and strain states of the valve leaflets during fixation with glutaraldehyde affect their final mechanical parameters. Comparative studies of the stress-strain relationships of aortic valve leaflet strips from fresh, statically and dynamically fixed porcine and human valves were made. Static pressures of 5 mmHg, 16 mmHg, and 95 mmHg result in stress-strain relationships which are in a region between that of fresh porcine and fresh human leaflet strips in the circumferential direction, while they are far from that of fresh porcine tissue (larger strains) in the radial direction. Leaflet strips, fixed under dynamic loading between zero and a predefined maximum load, set at an early post-transition state, give parameters not significantly different from those of human valves.  相似文献   

9.
TAVI devices are manufactured with cylindrical frames. However, the frames are rarely cylindrical post-deployment since deformation due to localised under expansion can be induced by calcified material on the native valve leaflets exerting irregular forces upon the frame. Consequently, the leaflets within a deformed TAVI device may undergo elevated stress during operation, which may lead to premature device failure.Using computational analysis a complete TAVI device model was simulated undergoing deployment into an aortic root model derived from CT data for a patient with severe calcific aortic stenosis, followed by a pressure simulated cardiac cycle. The complete analysis was performed eight times, each with the device at a different rotational orientation relative to the native valve, with an increment spacing of 15°.The TAVI device frames consistently featured significant distortions associated with bulky calcified material at the base of the non-coronary sinus. It was found that the average von Mises stress in the prosthetic valves was only increased in one of the cases relative to an idealised device. However, the maximum von Mises stress in the prosthetic valves was elevated in the majority of the cases.Furthermore, it was found that there were preferable orientations to deploy the prosthetic device, in this case, when the prosthetic leaflets were aligned with the native leaflets. As device orientation deviated from this orientation, the stresses in the valve increased because the distance between the prosthetic commissures decreased. This potentially could represent a sufficient increase in stress to induce variation in device lifespan.  相似文献   

10.
In aortic valve sparing surgery, cusp prolapse is a common cause of residual aortic insufficiency. To correct cusp pathology, native leaflets of the valve frequently require adjustment which can be performed using a variety of described correction techniques, such as central or commissural plication, or resuspension of the leaflet free margin. The practical question then arises of determining which surgical technique provides the best valve performance with the most physiologic coaptation. To answer this question, we created a new finite element model with the ability to simulate physiologic function in normal valves, and aortic insufficiency due to leaflet prolapse in asymmetric, diseased or sub-optimally repaired valves. The existing leaflet correction techniques were simulated in a controlled situation, and the performance of the repaired valve was quantified in terms of maximum leaflets stress, valve orifice area, valve opening and closing characteristics as well as total coaptation area in diastole. On the one hand, the existing leaflet correction techniques were shown not to adversely affect the dynamic properties of the repaired valves. On the other hand, leaflet resuspension appeared as the best technique compared to central or commissural leaflet plication. It was the only method able to achieve symmetric competence and fix an individual leaflet prolapse while simultaneously restoring normal values for mechanical stress, valve orifice area and coaptation area.  相似文献   

11.
Understanding the response of tissue structures to mechanical stress is crucial for optimization of mechanical conditioning protocols in the field of heart valve tissue engineering. In heart valve tissue, it is unclear to what extent mechanical loading affects the collagen fibril morphology. To determine if local stress affects the collagen fibril morphology, in terms of fibril diameter, its distribution, and the fibril density, this was investigated in adult native human aortic valve leaflets. Transmission electron microscopy images of collagen fibrils were analyzed at three locations: the commissures, the belly, and the fixed edge of the leaflets. Subsequently, the mechanical behavior of human aortic valves was used in a computational model to predict the stress distribution in the valve leaflet during the diastolic phase of the cardiac cycle. The local stresses at the three locations were related to the collagen fibril morphology. The fibril diameter and density varied significantly between the measured locations, and appeared inversely related. The average fibril diameter increased from the fixed edge, to the belly, and to the commissures of the leaflets, while fibril density decreased. Interestingly, these differences corresponded well with the level of stress at the locations. The presented data showed that large tissue stress is associated with greater average fibril diameter, lower fibril density, and wider fibril size distribution compared with low stress locations in the leaflets. The findings here provide insight in the effect of mechanical loading on the collagen ultrastructure, and are valuable to improve conditioning protocols for tissue engineering.  相似文献   

12.
The bicuspid aortic valve (BAV) is a common congenital malformation of the aortic valve (AV) affecting 1% to 2% of the population. The BAV is predisposed to early degenerative calcification of valve leaflets, and BAV patients constitute 50% of AV stenosis patients. Although evidence shows that genetic defects can play a role in calcification of the BAV leaflets, we hypothesize that drastic changes in the mechanical environment of the BAV elicit pathological responses from the valve and might be concurrently responsible for early calcification. An in vitro model of the BAV was constructed by surgically manipulating a native trileaflet porcine AV. The BAV valve model and a trileaflet AV (TAV) model were tested in an in vitro pulsatile flow loop mimicking physiological hemodynamics. Laser Doppler velocimetry was used to make measurements of fluid shear stresses on the leaflet of the valve models using previously established methodologies. Furthermore, particle image velocimetry was used to visualize the flow fields downstream of the valves and in the sinuses. In the BAV model, flow near the leaflets and fluid shear stresses on the leaflets were much more unsteady than for the TAV model, most likely due to the moderate stenosis in the BAV and the skewed forward flow jet that collided with the aorta wall. This additional unsteadiness occurred during mid- to late-systole and was composed of cycle-to-cycle magnitude variability as well as high-frequency fluctuations about the mean shear stress. It has been demonstrated that the BAV geometry can lead to unsteady shear stresses under physiological flow and pressure conditions. Such altered shear stresses could play a role in accelerated calcification in BAVs.  相似文献   

13.
This work was concerned with the numerical simulation of the behaviour of aortic valves whose material can be modelled as non-linear elastic anisotropic. Linear elastic models for the valve leaflets with parameters used in previous studies were compared with hyperelastic models, incorporating leaflet anisotropy with pronounced stiffness in the circumferential direction through a transverse isotropic model. The parameters for the hyperelastic models were obtained from fits to results of orthogonal uniaxial tensile tests on porcine aortic valve leaflets. The computational results indicated the significant impact of transverse isotropy and hyperelastic effects on leaflet mechanics; in particular, increased coaptation with peak values of stress and strain in the elastic limit. The alignment of maximum principal stresses in all models follows approximately the coarse collagen fibre distribution found in aortic valve leaflets. The non-linear elastic leaflets also demonstrated more evenly distributed stress and strain which appears relevant to long-term scaffold stability and mechanotransduction.  相似文献   

14.
Functional analysis of bioprosthetic heart valves   总被引:2,自引:0,他引:2  
Glutaraldehyde-treated bovine pericardium is used successfully as bioprosthetic material in the manufacturing of heart valves leaflets. The mechanical properties of bovine pericardial aortic valve leaflets seem to influence its mechanical behaviour and the failure mechanisms. In this study the effect of orthotropy on tricuspid bioprosthetic aortic valve was analysed, using a three-dimensional finite element model, during the entire cardiac cycle. Multiaxial tensile tests were also performed to determine the anisotropy of pericardium. Seven different models of the same valve were analysed using different values of mechanical characteristics from one leaflet to another, considering pericardium as an orthotropic material. The results showed that even a small difference between values along the two axes of orthotropy can negatively influence leaflets performance as regard both displacement and stress distribution. Leaflets of bovine pericardium bioprostheses could be manufactured to be similar to natural human heart valves reproducing their well-known anisotropy. In this way it could be possible to improve the manufacturing process, durability and function of pericardial bioprosthetic valves.  相似文献   

15.
Detailed comparisons of aortic valvular flow using saline, with that using a glycerin-based blood analog in a pulse duplicator are reported. The experiments were carried out to determine whether exposure to glycerin caused stiffening of bioprosthetic valve leaflets. For two pericardial bioprostheses and for a mechanical valve we observed a fluid-dependent systolic volume flow, a fluid-dependent regurgitation volume, and fluid-dependent systolic pressure differences. Volume flow changes, both forward and reverse, are independent of valve type. The observed pressure differences, while proportional to fluid density for the mechanical valve, are fluid dependent in a more complicated way for the pericardial valves. However, no trend of changing valvular performance was observed over as much as 80 days of glycerin exposure, indicating that it is unlikely that the fluid-dependent performance was caused by glycerin absorption by the valve leaflets. We conclude that valid performance comparisons between mechanical and bioprosthetic valves may be made using a glycerin-based fluid. Furthermore, it appears that any detailed analysis of the physical mechanisms of valvular flow dissipation will require a properly matched blood analog.  相似文献   

16.
The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)--the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional model geometry of a straight conduit with sudden expansion distal the valves, including the valve housing and detailed hinge geometry. An aortic flow waveform (60 beats/min, cardiac output 4 l/min) was applied at the inlet. The FSI formulation utilized a fully implicit coupling procedure using a separate solver for the fluid problem (FLUENT) and for the structural problem. Valve leaflet excursion and pressure differences were calculated, as well as shear stress on the leaflets and accumulated shear stress on particles released during both forward and backward flow phases through the open and closed valve, respectively. In contrast to the SJM, the ATS valve opened to less than maximal opening angle. Nevertheless, maximal and mean pressure gradients and velocity patterns through the valve orifices were comparable. Platelet stress accumulation during forward flow indicated that no platelets experienced a stress accumulation higher than 35 dyne x s/cm2, the threshold for platelet activation (Hellums criterion). However, during the regurgitation flow phase, 0.81% of the platelets in the SJM valve experienced a stress accumulation higher than 35 dyne x s/cm2, compared with 0.63% for the ATS valve. The numerical results indicate that the designs of the ATS and SJM valves, which differ mostly in their hinge mechanism, lead to different potential for platelet activation, especially during the regurgitation phase. This numerical methodology can be used to assess the effects of design parameters on the flow induced thrombogenic potential of blood recirculating devices.  相似文献   

17.
The goal of the present study was to obtain a systematic set of data along the length of the mouse aorta to study variations of morphometry (diameter, wall thickness, and curvature), strain, and stress of the mouse aorta. Five mice were imaged with a 13-MHz ultrasound probe to determine the in vivo diameter along the aorta. A cast was made of these aortas to validate the ultrasonic diameter measurements. The root mean squared and systematic errors for these measurements were 12.6% and 6.4% of the mean ultrasound diameter, respectively. The longitudinal variations of geometry, stress, and strain from the aortic valve to the common iliac bifurcation were documented. Our results show that the residual circumferential strain leads to a uniformity of transmural strain of the aorta in the loaded state along the entire length of the aorta. Furthermore, we validated the incompressibility condition along the length of the aorta. These data of normal mice will serve as a reference state for the study of disease in future knockout models.  相似文献   

18.
A nonlinear anisotropic model for porcine aortic heart valves   总被引:2,自引:0,他引:2  
Li J  Luo XY  Kuang ZB 《Journal of biomechanics》2001,34(10):1279-1289
The anisotropic property of porcine aortic valve leaflet has potentially significant effects on its mechanical behaviour and the failure mechanisms. However, due to its complex nature, testing and modelling the anisotropic porcine aortic valves remains a continuing challenge to date. This study has developed a nonlinear anisotropic finite element model for porcine heart valves. The model is based on the uniaxial experimental data of porcine aortic heart valve leaflet and the properties of nonlinear composite material. A finite element code is developed to solve this problem using the 8-node super-parameter nonlinear shells and the update Lagrangian method. The stress distribution and deformation of the porcine aortic valves with either uniform and non-uniform thicknesses in closed phase and loaded condition are calculated. The results showed significant changes in the stress distributions due to the anisotropic property of the leaflets. Compared with the isotropic valve at the same loading condition, it is found that the site of the peak stress of the anisotropic leaflet is different; the maximum longitudinal normal stress is increased, but the maximum transversal normal stress and in-plane shear stress are reduced. We conclude that it is very important to consider the anisotropic property of the porcine heart valves in order to understand the failure mechanism of such valves in vivo.  相似文献   

19.
Left ventricular (LV) longitudinal and transverse geometric changes during isovolumic contraction and relaxation are still controversial. This confusion is compounded by traditional definitions of these phases of the cardiac cycle. High-resolution sonomicrometry studies might clarify these issues. Crystals were implanted in six sheep at the LV apex, fibrous trigones, lateral and posterior mitral annulus, base of the aortic right coronary sinus, anterior and septal endocardial wall, papillary muscle tips, and edge of the anterior and posterior mitral leaflets. Changes in distances were time related to LV and aortic pressures and to mitral valve opening. At the beginning of isovolumic contraction, while the mitral valve was still open, the LV endocardial transverse diameter started to shorten while the endocardial longitudinal diameter increased. During isovolumic relaxation, while the mitral valve was closed, LV transverse diameter started to increase while the longitudinal diameter continued to decrease. These findings are inconsistent with the classic definitions of the phases of the cardiac cycle.  相似文献   

20.
T Koyama  M Horimoto 《Biorheology》1988,25(1-2):219-226
Lymphatic microvessels were microscopically observed on the surface of frog lungs. Magnified images of lymphatic microvessels were recorded on video tapes. The lymphatic microcirculation was studied on a TV monitor at the magnification of 1500 times. 1) valves were observed in lymphatic microvessels, whose diameter was 15 micron, in frog lungs, 2) the valves were incompetent, 3) contained particles repeatedly flowed backwards and forwards in each lymphatic section, 4) after repetition of the movements, particles passed through the outlet valve, 5) particles seldom flowed back through the inlet valve into the preceding section of the lymphatic, 6) the peak flow velocity of particles attained 0.5 mm/sec, and 7) the mean flow velocity was 11 +/- 4 micron on an average and +/- SD, 8) the diameter of a localized portion of the lymphatic microvessels changed periodically.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号