首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
A defined substrate method was developed to simultaneously enumerate total coliforms and Escherichia coli from drinking waters without the need for confirmatory or completed tests. It is a new method based on technology that uses a hydrolyzable substrate as a specific indicator-nutrient for the target microbes. No equipment other than a 35 degrees C incubator and long-wavelength (366-nm) light is necessary. To perform the test, one only has to add water to the powdered ingredients in a tube or flask. If total coliforms are present in the water sample, the solution will change from its normal colorless state (no target microbes present) to yellow. The specific presence of E. coli will cause the same tube to fluoresce under a longwave (366-nm) UV lamp. The test, called Autoanalysis Colilert (AC), was compared with Standard Methods for the Examination of Water and Wastewater 10-tube multiple tube fermentation (MTF) in a national evaluation. Five utilities, representing six U.S. Environmental Protection Agency regions, participated. All water samples came from distribution systems. Split samples from a wide variety of water sources were analyzed for the MPN-versus-MPN comparison. A total of 1,086 tubes were positive by MTF, and 1,279 were positive by AC. There was no statistical difference between MTF and AC. Species identifications from positive tubes confirmed the sensitivity of the AC. A national evaluation of the AC test showed that it: (i) was as sensitive as Standard Methods MTF, (ii) specifically enumerated 1 total coliform per 100 ml, in a maximum of 24 h, (iii) simultaneously enumerated 1 E. coli per 100 ml in the same analysis, (iv) was not subject to false-positive or false-negative results by heterotrophic bacteria, (v) did not require confirmatory tests, (vi) grew injured coliforms, (vii) was easy to inoculate, and (viii) was very easy to interpret.  相似文献   

2.
Many water utilities are required to monitor source water for the presence of total coliforms, fecal coliforms, or both. The Colilert system, an application of the defined substrate technology, simultaneously detects the presence of both total coliforms and Escherichia coli directly from a water sample. After incubation, the formula becomes yellow if total coliforms are present and fluorescent at 366 nm if E. coli is in the same sample. No confirmatory tests are required. The Colilert system was previously assessed with distribution water in a national evaluation in both most-probably-number and presence-absence formats and found to produce data equivalent to those obtained by using Standard Methods for the Examination of Water and Wastewater (Standard Methods). The Colilert system was now compared with Standard Methods multiple-tube fermentation (MTF) for the enumeration of total coliforms and E. coli from surface water. All MTF tubes were confirmed according to Standard Methods, and subcultures were made to identify isolates to the species level. The Colilert system was found equally sensitive to MTF testing by regression, t test, chi-square, and likelihood fraction analyses. Specificity of the Colilert system was shown by the isolation of a species of total coliform or E. coli after the appropriate color change. The Colilert test can be used for source water samples when enumeration is required, and the benefits previously described for distribution water testing--sensitivity, specificity, less labor, lower cost, faster results, no noncoliform heterotroph interference--are applicable to this type of water analysis.  相似文献   

3.
Many water utilities are required to monitor source water for the presence of total coliforms, fecal coliforms, or both. The Colilert system, an application of the defined substrate technology, simultaneously detects the presence of both total coliforms and Escherichia coli directly from a water sample. After incubation, the formula becomes yellow if total coliforms are present and fluorescent at 366 nm if E. coli is in the same sample. No confirmatory tests are required. The Colilert system was previously assessed with distribution water in a national evaluation in both most-probably-number and presence-absence formats and found to produce data equivalent to those obtained by using Standard Methods for the Examination of Water and Wastewater (Standard Methods). The Colilert system was now compared with Standard Methods multiple-tube fermentation (MTF) for the enumeration of total coliforms and E. coli from surface water. All MTF tubes were confirmed according to Standard Methods, and subcultures were made to identify isolates to the species level. The Colilert system was found equally sensitive to MTF testing by regression, t test, chi-square, and likelihood fraction analyses. Specificity of the Colilert system was shown by the isolation of a species of total coliform or E. coli after the appropriate color change. The Colilert test can be used for source water samples when enumeration is required, and the benefits previously described for distribution water testing--sensitivity, specificity, less labor, lower cost, faster results, no noncoliform heterotroph interference--are applicable to this type of water analysis.  相似文献   

4.
The Autoanalysis Colilert (AC) test was compared with the membrane filter (MF), 10-tube multiple-tube fermentation (MTF) technique, and the presence-absence test as described in Standard Methods for the Examination of Water and Wastewater for the detection and enumeration of total coliforms in water. The methods were evaluated with 31 samples from seven different sources. Each sample was analyzed by each of the techniques, using replicate 100-ml sample volumes. A total of 582 confirmed tubes were positive by the MTF test, and 533 tubes were positive by the AC test. Statistical analysis of the most-probable-number comparability data showed a statistically significant difference in the number of positive tubes, with the MTF test resulting in more positive tubes. There were no statistically significant differences in precision between the two methods. All the methods were comparable in detection of total coliforms. Levels of heterotrophic bacteria generally encountered in drinking water did not interfere with detection or enumeration of coliforms by the AC test.  相似文献   

5.
The Autoanalysis Colilert (AC) test was compared with the membrane filter (MF), 10-tube multiple-tube fermentation (MTF) technique, and the presence-absence test as described in Standard Methods for the Examination of Water and Wastewater for the detection and enumeration of total coliforms in water. The methods were evaluated with 31 samples from seven different sources. Each sample was analyzed by each of the techniques, using replicate 100-ml sample volumes. A total of 582 confirmed tubes were positive by the MTF test, and 533 tubes were positive by the AC test. Statistical analysis of the most-probable-number comparability data showed a statistically significant difference in the number of positive tubes, with the MTF test resulting in more positive tubes. There were no statistically significant differences in precision between the two methods. All the methods were comparable in detection of total coliforms. Levels of heterotrophic bacteria generally encountered in drinking water did not interfere with detection or enumeration of coliforms by the AC test.  相似文献   

6.
A defined substrate method was applied to drinking water to simultaneously enumerate total coliforms and total Escherichia coli directly from samples. After incubation at 35 degrees C for 24 h, the development of yellow in an initially colorless solution was specific for total coliforms; fluorescence at 366 nm in the same tube(s) or vessel demonstrated the presence of E. coli. No confirmatory or completed steps were necessary. Known as autoanalysis colilert (AC), this method was constituted as a presence-absence test and compared with the methods described in Standard Methods (SM) in the P-A format. Seven water utilities representing a wide geological and hydrological spectrum participated in the evaluation. A total of 702 split drinking water samples were analyzed. Of these, 358 were negative in both tests (SM- and AC-); 302 were positive (SM+ and AC+); and 42 were mixed (SM+ and AC-, 20; AC+ and SM-, 22). The overall agreement rate was 94%. Comparison of the SM and AC results by nonparametric statistics demonstrated no differences. Heterotrophic plate count bacteria exerted no discernible effect on the AC test. By subculture, each time the AC test was yellow, a total coliform was present; when the test was fluorescent, E. coli was isolated.  相似文献   

7.
A defined substrate method was applied to drinking water to simultaneously enumerate total coliforms and total Escherichia coli directly from samples. After incubation at 35 degrees C for 24 h, the development of yellow in an initially colorless solution was specific for total coliforms; fluorescence at 366 nm in the same tube(s) or vessel demonstrated the presence of E. coli. No confirmatory or completed steps were necessary. Known as autoanalysis colilert (AC), this method was constituted as a presence-absence test and compared with the methods described in Standard Methods (SM) in the P-A format. Seven water utilities representing a wide geological and hydrological spectrum participated in the evaluation. A total of 702 split drinking water samples were analyzed. Of these, 358 were negative in both tests (SM- and AC-); 302 were positive (SM+ and AC+); and 42 were mixed (SM+ and AC-, 20; AC+ and SM-, 22). The overall agreement rate was 94%. Comparison of the SM and AC results by nonparametric statistics demonstrated no differences. Heterotrophic plate count bacteria exerted no discernible effect on the AC test. By subculture, each time the AC test was yellow, a total coliform was present; when the test was fluorescent, E. coli was isolated.  相似文献   

8.
The current investigation was carried out in order to compare directly the multiple tube fermentation method (MTF), using standard procedures (lactose broth, LB) and the Colilert reagent, with the membrane filter method (MF) using Les Endo agar (LEA), m-faecal coliform agar (mFCA) and chromogenic coliform agar (CCA), for recovery of coliforms and Escherichia coli in 80 surface water samples. Total coliforms were isolated from 100% of samples by all methodologies. Faecal coliforms/E. coli were detected in 100% of samples by MTF methods, but only in 75.5% by MF-mFCA and in 86.2% by MF-CCA. Even if MTF-LB counts were consistently higher, the Colilert reagent accurately determined total coliforms and E. coli levels within 24 h with no additional confirmatory tests. Therefore, it could be a powerful tool for rapidly assessing possible faecal contamination and a suitable alternative to the traditional MTF and MF techniques utilized for coliform detection.  相似文献   

9.
The examination of water and other environmental sources for microbial pollution is a major public health undertaking. Currently, there are two accepted methods in use: the multiple-tube fermentation (MTF) and the membrane filtration (MF) tests. Both methods are designed to enumerate the secondary indicator group, total coliforms. Both tests suffer several inherent limitations, including a time delay of three to seven days to obtain a definitive result, the subjective nature of the test interpretation, and the inability to provide directly useful public health information. A defined substrate technology, originally used to enumerate specific bacterial species from mixtures in clinical urine specimens, was applied to water testing; the technology was constituted to enumerate simultaneously both total coliforms and the primary indicator bacterium E. coli. Examination of environmental isolates of these two classes of target microbes showed sensitivity equal to available methods, with potentially greater specificity. It was not subject to inhibition by bacteria other than the targets, grew injured coliforms, did not require confirmatory tests, and the maximum time to a positive was 24 hours. The defined substrate technology provides both regulatory and directly useful public health information.  相似文献   

10.
A test that allows for early detection of fecally contaminated coastal water would enhance public health protection. Colilert-Marine Water (Colilert-MW; Environetics, Branford, Conn.) is a rapid 24-h test that has recently been developed to detect total coliforms and Escherichia coli in coastal water. We performed a premarketing evaluation of the Colilert-MW product, testing it in parallel with the multiple tube fermentation (MTF) method for 86 coastal water samples in southern California. Statistical analysis was performed by using paired t tests and linear regression. Bacterial isolates were evaluated by biochemical and genetic analysis. The results of this study showed a strong correlation between the traditional MTF and the Colilert-MW method for detection of total coliforms (r = 0.95) and E. coli (r = 0.89) in ocean water samples. Paired t-test results indicated that the Colilert-MW and MTF were equivalent in detecting E. coli and that the Colilert-MW may be more sensitive in the detection of total coliforms. We conclude that Colilert-MW would be a useful tool with which to monitor coastal beach water.  相似文献   

11.
This study compared the performance of LMX(R) broth (LMX), Chromocult Coliform(R) agar (CC) and Chromocult Coliform agar plus cefsulodin (10 microg ml-1) (CC-CFS), with standard methods multiple tube fermentation (MTF), for the enumeration of total coliforms and Escherichia coli from marine recreational waters. LMX and CC are two media designed to concurrently detect total coliform (TC) bacteria and E. coli by the specific action of beta-galactosidase (total coliforms) and beta-glucuronidase (E. coli). Overall results for the TC test showed that LMX, CC and MTF recovered 2.63, 1.95 and 1.90 times as many TCs as CC-CFS, respectively. Data from the multiple range test showed significant differences (P < 0.05) between TC counts on CC-CFS and LMX. The traditional MTF was less sensitive for E. coli enumeration. However, there was no statistically significant differences between LMX, CC, CC-CFS and the MTF method for E. coli enumeration. Background interference was reduced on CC-CFS and the counts obtained reflected more accurately the number of TCs. Therefore, the contribution of beta-galactosidase positive, non coliform bacteria (Aeromonas spp. and Vibrio spp.) to TC counts should not be neglected.  相似文献   

12.
A most-probable-number (MPN) technique was evaluated for detecting and enumerating Pseudomonas aeruginosa in water and wastewater. Both the presumptive and confirmatory media, as described in the 13th edition of Standard Methods for the Examination of Water and Wastewater, as well as modifications of these media were included in evaluations. Various samples of water were tested, namely chlorinated tap water, creek water, and influent to a wastewater treatment plant. Modified media repeatedly gave higher estimated MPNs of P. aeruginosa than media listed in Standard Methods. P. aeruginosa was detected and recovered from all creek water and wastewater samples, but not from tap water samples tested. This organism was determined to be present in as large numbers as the fecal coliforms and in even greater quantities than the fecal streptococci in all samples, whenever MPN estimations were determined from those positive tubes containing the modified confirmatory medium.  相似文献   

13.
Fluorogenic assays for immediate confirmation of Escherichia coli.   总被引:50,自引:23,他引:27       下载免费PDF全文
Rapid assays for Escherichia coli were developed by using the compound 4-methylumbelliferone glucuronide (MUG), which is hydrolyzed by glucuronidase to yield a fluorogenic product. The production of glucuronidase was limited to strains of E. coli and some Salmonella and Shigella strains in the family Enterobacteriaceae. For immediate confirmation of the presence of E. coli in most-probable-number tubes, MUG was incorporated into lauryl tryptose broth at a final concentration of 100 micrograms/ml. Results of both the presumptive test (gas production) and the confirmed test (fluorescence) for E. coli were obtained from a variety of food, water, and milk samples after incubation for only 24 h at 35 degrees C. Approximately 90% of the tubes showing both gas production and fluorescence contained fecal coliforms (they were positive in EC broth incubated at 45 degrees C). Few false-positive reactions were observed. The lauryl tryptose broth-MUG-most-probable-number assay was superior to violet red bile agar for the detection of heat- and chlorine-injured E. coli cells. Anaerogenic strains produced positive reactions, and small numbers of E. coli could be detected in the presence of large numbers of competing bacteria. The fluorogenic assay was sensitive and rapid; the presence of one viable cell was detected within 20 h. E. coli colonies could be distinguished from other coliforms on membrane filters and plates of violet red bile agar if MUG was incorporated into the culture media. A rapid confirmatory test for E. coli that is amenable to automation was developed by using microtitration plates filled with a nonselective medium containing MUG. Pure or mixed cultures containing E. coli produced fluorescence within 4 h (most strains) to 24 h (a few weakly positive strains).  相似文献   

14.
A rapid, defined substrate technology method, commercially available as Colilert, simultaneously enumerates total coliforms and Escherichia coli in drinking water samples in 24 h without the need for confirmatory tests. The ability of this method to enumerate both total coliforms and E. coli in simulated chlorine-treated drinking water samples was compared with the standard UK method (minerals-modified glutamate most probable number) which requires up to 96 h to complete including confirmation. Statistical analysis by a nonparametric matched-pair test showed the Colilert method to be less efficient at detecting down to one E. coli in these samples compared to the standard UK method. No statistically significant difference between the two methods of enumeration for total coliforms was detected.  相似文献   

15.
A total of 529 well and distribution potable water samples were analyzed for total coliforms by the most-probable-number and membrane filter (MF) techniques. Standard plate count bacteria and MF noncoliform bacteria were also enumerated. Frequency of coliform detection, turbidity in most-probable-number tubes, and extensive overgrowth by noncoliforms on MF filters were directly proportional to standard plate counts. Recovery of coliforms was greatest by the MF method at low (less than 100 CFU/ml) standard plate count densities and better by the most-probable-number method (confirming gas and turbid tube) at high (greater than 500 CFU/ml) standard plate count densities. In the latter case, overgrowth by noncoliforms on MF filters suppressed sheen development and, in turn, masked coliform detection. Of 341 atypical (no sheen) MF colonies verified by parallel inoculation of lauryl sulfate broth and billiant green-bile broth, 156 were aerogenic in the latter medium. Of atypical isolates, 84% were identified as either Citrobacter or Enterobacter species. A 4.3-fold reduction in numbers of overgrown MF filters and an 2.2-fold increase in numbers of coliforms recovered from 127 water samples was accomplished by anaerobic incubation of MF cultures. This anaerobic modification of the standard MF technique significantly reduced overgrowth and enhanced recovery of coliforms from potable groundwater. This technique is simple, cost effective, and suitable for monitoring of untreated ground water common to some small water systems and private water supplies.  相似文献   

16.
A total of 529 well and distribution potable water samples were analyzed for total coliforms by the most-probable-number and membrane filter (MF) techniques. Standard plate count bacteria and MF noncoliform bacteria were also enumerated. Frequency of coliform detection, turbidity in most-probable-number tubes, and extensive overgrowth by noncoliforms on MF filters were directly proportional to standard plate counts. Recovery of coliforms was greatest by the MF method at low (less than 100 CFU/ml) standard plate count densities and better by the most-probable-number method (confirming gas and turbid tube) at high (greater than 500 CFU/ml) standard plate count densities. In the latter case, overgrowth by noncoliforms on MF filters suppressed sheen development and, in turn, masked coliform detection. Of 341 atypical (no sheen) MF colonies verified by parallel inoculation of lauryl sulfate broth and billiant green-bile broth, 156 were aerogenic in the latter medium. Of atypical isolates, 84% were identified as either Citrobacter or Enterobacter species. A 4.3-fold reduction in numbers of overgrown MF filters and an 2.2-fold increase in numbers of coliforms recovered from 127 water samples was accomplished by anaerobic incubation of MF cultures. This anaerobic modification of the standard MF technique significantly reduced overgrowth and enhanced recovery of coliforms from potable groundwater. This technique is simple, cost effective, and suitable for monitoring of untreated ground water common to some small water systems and private water supplies.  相似文献   

17.
A commercial gene probe assay kit for presence/absence determination of Escherichia coli in food samples has been used in the standard UK six tube format most probable number (MPN) method for enumerating E. coli in drinking water samples. Presence/absence analysis with the gene probe kit (requiring 3 h) of all MPN tubes after a 21–24 h incubation (minerals modified glutamate; 37°C) enumerated confirmed E. coli in 24–27 h which offered an improvement of up to 48 h over the standard UK MPN method. MPNs determined by the gene probe method and the standard UK method agreed in nine of the 16 water samples which were analysed and for which E. coli concentrations were within the detection limits of the six tube MPN format. This was consistent with the gene probe method detecting one E. coli in a tube. For the other seven water samples, the gene probe method registered positive only 20 of the 30 tubes which the standard UK method determined to be positive. The sensitivity of the gene probe method for drinking water samples, although encouraging, needs improvement perhaps through kit quality control procedures.  相似文献   

18.
Over a 4-month period, 950 samples of treated drinking water were analyzed for total coliforms (TC) and Escherichia coli by both membrane filtration (MF) and Autoanalysis Colilert presence-absence (AC) techniques. The two tests agreed 97% of the time on the basis of presumptive TC results and 98.5% of the time on the basis of verified TC results. Samples which produced disagreement between the two tests were most often TC positive by MF and TC negative by AC. E. coli was recovered four times: twice by MF only, and twice by AC only but without the diagnostic fluorescence reaction. In two samples, E. coli could not be isolated from fluorescence-positive AC tests. On the basis of these results, the AC test was implemented as the routine analytical procedure for TC but not for E. coli.  相似文献   

19.
C M Lewis  J L Mak 《Applied microbiology》1989,55(12):3091-3094
Over a 4-month period, 950 samples of treated drinking water were analyzed for total coliforms (TC) and Escherichia coli by both membrane filtration (MF) and Autoanalysis Colilert presence-absence (AC) techniques. The two tests agreed 97% of the time on the basis of presumptive TC results and 98.5% of the time on the basis of verified TC results. Samples which produced disagreement between the two tests were most often TC positive by MF and TC negative by AC. E. coli was recovered four times: twice by MF only, and twice by AC only but without the diagnostic fluorescence reaction. In two samples, E. coli could not be isolated from fluorescence-positive AC tests. On the basis of these results, the AC test was implemented as the routine analytical procedure for TC but not for E. coli.  相似文献   

20.
The new United States Drinking Water Regulations state that water systems must analyze for Escherichia coli or fecal coliforms on any routine or repeat sample that is positive for total coliforms. The proposed methods for the detection of E. coli are based on beta-glucuronidase activity, using the fluorogenic substrate 4-methylumbelliferyl beta-D-glucuronide (MUG). This study was conducted to determine whether beta-glucuronidase negative E. coli were present in significant numbers in environmental waters. Two hundred and forty E. coli cultures were isolated from 12 water samples collected from different environmental sources. beta-glucuronidase activity was determined using lauryl tryptose broth with MUG, EC broth with MUG, and the Autoanalysis Colilert (AC) procedure. The isolates were also evaluated by the standard EC broth gas fermentation method for fecal coliforms. The results confirm that assaying for the enzyme beta-glucuronidase utilizing the MUG substrate is an accurate method for the detection of E. coli in environmental waters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号