首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Central venous obstruction following pacemaker implantation is not uncommon, and can prove challenging in the case of system upgrade. We report a case of DDDR to CRT-P (with multi-site pacing) upgrade, where a subclavian occlusion was overcome resorting to an atrial lead extraction (using only a locking stylet). This allowed regaining of the venous access with subsequent implantation of not just one, but two new leads and subsequent successful upgrade.  相似文献   

2.
This case highlights the importance of proper identification of congenital anomalies of the coronary sinus for the successful placement of left ventricular lead during cardiac resynchronization therapy device implantation. We discuss an alternate route for left ventricular lead placement via the vein of Marshall when the coronary sinus ostium in the right atrium was atretic and was facing difficulty initially in detecting the anomaly.  相似文献   

3.
Cardiac resynchronisation therapy (CRT) is a recognised therapy for the management of severe left ventricular dysfunction, advanced congestive cardiac failure (NYHA III or IV), ventricular dyssynchrony (either broad LBBB or mechanical dyssynchrony on echocardiography) and failure of optimal medical therapy to achieve improvement in clinical status. Upgrading right ventricular pacemakers or defibrillators to biventricular devices is common and we describe here, 2 such cases of biventricular upgrade with blocked venous access on the ipsilateral side and successful placement of left ventricular leads following pre-sternal tunnelling from the contralateral side.  相似文献   

4.
Venous revascularization is an approach used in patients with total venous occlusion requiring venous access for cardiac device lead placement. Several percutaneous approaches to venous revascularization have been proposed. For the first time, we describe the case of a 69-year-old male with total venous occlusion who was successfully revascularized using a ‘diathermy’ technique.  相似文献   

5.
The cutdown technique for the cephalic vein is a common access route for transvenous cardiac device leads (TVLs), and sometimes one cephalic vein can accomodate two TVLs. We examined a novel ligation technique to balance the hemostasis and lead maneuverability for this two-in-one insertion. A total of 22 patients scheduled for cardiac device implantations with two or more leads were enrolled. The ipsilateral cephalic vein was identified for inserting the TVLs with a cutdown. If two TVLs could be introduced into one cephalic vein, hemostasis was established by ligating the venous wall between the TVLs. We measured the amount of hemorrhaging per minute and the operators assessed the lead maneuverability before and after the ligation. We successfully implanted cardiac devices in 15 patients (68%) with this novel method, whereas only one TVL could be introduced via the cephalic vein in 7 patients. As for the successful patients, hemorrhaging from the gap was significantly reduced (5.6?±?7.3 to 0.41?±?0.36g/min, p?=?0.016) after the novel ligation. The lead maneuverability was well maintained so there was no difficulty placing the leads into the cardiac chambers in all cases. No major complications were observed. In the present study, the novel ligation method provided significant hemostasis as well as a preserved maneuverability. It could be an optional choice for insertion of multiple TVLs.  相似文献   

6.
The preference for treatment of symptomatic bradycardia is transvenous right ventricular pacing combined with atrial synchronisation if applicable. In the case of congenital anomalies where no conduit is present between the peripheral veins and the right ventricle, it is not possible to place the ventricular pacing lead in the right ventricle. Also the presence of an artificial valve in the tricuspid position excludes placement of an endocardial right ventricular pacing lead. Since the introduction of biventricular pacing, new guiding catheters and leads used as a transvenous route for left ventricular pacing are available. We report implantation of a ventricular pacing lead in the great cardiac vein for permanent ventricular pacing in a patient with a tricuspid valve prosthesis.  相似文献   

7.
BackgroundUltrasound-guided axillary venous puncture (UGAVP) for cardiac devices implantation has been developed because of its rapidity, safety and potential long-term lead protection. Early work excluded defibrillators (ICD), cardiac resynchronization therapy (CRT) and upgrade procedures. Compared to the cephalic approach, in previous studies, there was a greater use of pressure dressings with this technique, suggesting a higher risk of bleeding.AimsTo assess UGAVP in patients under antithrombotic therapy (ATT) undergoing cardiac devices implantation including CRT/ICD.MethodsProspectively, consecutive patients eligible for a pacemaker or ICD implantation were included. All procedures were performed by a single operator, experienced with UGAVP for femoral access, and fluoroscopy-guided axillary vein access. Guidewires insertion time (from lidocaïne administration), and complications were systematically studied.ResultsFrom 457 cardiac device implantations, 200 patients (77.8 ± 10 y, male 58%) 360 leads were implanted by UGAVP including 36 ICD, 54 CRT and 14 upgrade procedures. A majority (90%) was under ATT: Vitamin K Antagonist or Heparin (n = 58, 29%), direct oral anticoagulant (n = 46, 23%), dual antithrombotic therapy (n = 18, 9%) and single antiplatelet drug (n = 82, 41%). UGAVP was successful in 95.78%. Mean insertion time for 1.8 guidewires per patient was 4.68 ± 3.6 min. No complication (no hematoma) was observed during the follow-up (mean of 45 ± 10 months). Guidewires insertion time reached its plateau after 15 patients.ConclusionUGAVP is fast, feasible and safe for patients under ATT undergoing device implantation including CRT/ICD and upgrade procedures, with a short learning curve.  相似文献   

8.
Persistent left superior vena cava (PLSVC) is an uncommon congenital anomaly. We report a case of implantation of cardiac resynchronization therapy - pacemaker (CRT-P) device in a 38-year-old lady with idiopathic dilated cardiomyopathy. After left axillary vein puncture, we faced an unexpected entry of left subclavian to PLSVC draining into the coronary sinus (CS). The target posterolateral vein which had been identified before, seemed to have an acute angle at its entry into the CS. Hence, at this stage we were in a dilemma, whether to switch to the right side or to continue from the same side. We continued the procedure from the left side and completed it successfully after some manipulation and improvisation.  相似文献   

9.
The objective of this study was to describe the uncommon connections between cardiac veins, alternative pathways within cardiac venous circulation and complex variability of the venous system in the heart ventricles. The study was carried out on 30 adult New Zealand White rabbits. The arrangement of the cardiac veins was studied by using the corrosion casts prepared with the Spofacryl® and by perfusion of coloured latex. The presence and organization of principal veins of the heart ventricles was relatively constant with a great variability in the mode of opening and forming a common trunk. The highest variations were observed in the region of the paraconal interventricular vein, the left and right marginal vein and the left distal ventricular vein. The left proximal ventricular vein was an inconstant tributary of the left circumflex vein and was seen in 17% of cases. The left distal ventricular vein was visible as one (13% of cases) or two veins (87% of cases). Angular vein was observed in 20% of cases. Numerous anastomosis were found among cardiac veins.  相似文献   

10.
Mutations in the gene for polycystin 2 (Pkd2) lead to polycystic kidney disease, however the main cause of mortality in humans is cardiac related. We previously showed that 5 month old Pkd2+/- mice have altered calcium-contractile activity in cardiomyocytes, but have preserved cardiac function. Here, we examined 1 and 9 month old Pkd2+/- mice to determine if decreased amounts of functional polycystin 2 leads to impaired cardiac function with aging. We observed changes in calcium handling proteins in 1 month old Pkd2+/- mice, and these changes were exacerbated in 9 month old Pkd2+/- mice. Anatomically, the 9 month old Pkd2+/- mice had thinner left ventricular walls, consistent with dilated cardiomyopathy, and the left ventricular ejection fraction was decreased. Intriguingly, in response to acute isoproterenol stimulation to examine β-adrenergic responses, the 9 month old Pkd2+/- mice exhibited a stronger contractile response, which also coincided with preserved localization of the β2 adrenergic receptor. Importantly, the Pkd2+/- mice did not have any renal impairment. We conclude that the cardiac-related impact of decreased polycystin 2 progresses over time towards cardiac dysfunction and altered adrenergic signaling. These results provide further evidence that polycystin 2 provides a critical function in the heart, independent of renal involvement.  相似文献   

11.
T Miyaki  M Yamada  K Kumaki 《Acta anatomica》1987,130(3):275-279
Two livers with an aberrant course of the left gastric vein were found in 245 Japanese cadavers. The left gastric vein collects branches from the lesser curvature of the stomach, enters the left side of the hepatogastric ligament from the cardiac region and runs towards the left side of hepatic hilus. The vein enters the liver at the left side and joins an intrahepatic branch ramified from the portal vein.  相似文献   

12.

Background

The number of cardiac rhythm device implantations has been growing fast due to expanding indications and ageing of the population. Complications of implantation were rare in the trials. However, these involved small numbers and selected patients. Prospective real-life data are necessary to assess cardiac device implantation procedure-related risks.

Objective

To determine the incidence and predictors of lead-related re-intervention in a Dutch high-volume teaching hospital.

Methods

Data from all patients who underwent cardiac rhythm device implantation between January 2010 and December 2011 were collected in a prospective registry. At least 1 year of follow-up regarding re-intervention was available for all patients. Lead-related reasons for re-intervention were categorised into lead dislodgement, malfunctioning or perforation.

Results

One thousand nine hundred twenty-nine devices including 3909 leads were implanted. In 595 patients (30.8 %) a CRT-D/P was implanted. Lead-related re-intervention was necessary in 86 (4.4 %) patients; it was more common in younger and male patients, and due to either lead dislodgement (66 %), malfunctioning (20 %) or perforation (18 %). Coronary sinus lead dislodgement or malfunctioning was 1.4 %. Right atrial dislodgement (1.9 %, p < 0.001) or ICD lead dislodgement (1.8 %, p = 0.002) was more common than right ventricular dislodgement (0.3 %). The incidence of lead malfunctioning was higher (0.8 %) in ICD leads. An apical position of the right ventricular lead and lateral wall position of the right atrial lead were related to cardiac perforation.

Conclusions

The incidence of lead-related re-intervention was comparable with the literature. The majority of re-interventions were due to lead dislodgements, particularly with right atrial and ICD leads. Re-intervention due to coronary sinus lead dislodgement was rare.  相似文献   

13.

Background

We aimed to assess whether we could identify a graded association between increasing number of components of the metabolic syndrome and cardiac structural and functional abnormalities independently of predicted risk of coronary heart disease by the Framingham risk score.

Methods

We conducted a cross-sectional study on a random sample of the urban population of Porto aged 45 years or over. Six hundred and eighty-four participants were included. Data were collected by a structured clinical interview with a physician, ECG and a transthoracic M-mode and 2D echocardiogram. The metabolic syndrome was defined according to ATPIII-NCEP. The association between the number of features of the metabolic syndrome and the cardiac structural and functional abnormalities was assessed by 3 multivariate regression models: adjusting for age and gender, adjusting for the 10-year predicted risk of coronary heart disease by Framingham risk score and adjusting for age, gender and systolic blood pressure.

Results

There was a positive association between the number of features of metabolic syndrome and parameters of cardiac structure and function, with a consistent and statistically significant trend for all cardiac variables considered when adjusting for age and gender. Parameters of left ventricular geometry patterns, left atrial diameter and diastolic dysfunction maintained this trend when taking into account the 10-year predicted risk of coronary heart disease by the Framingham score as an independent variable, while left ventricular systolic dysfunction did not. The prevalence of left ventricular diastolic dysfunction, and the mean left ventricular mass, left ventricular diameter and left atrial diameter increased significantly with the number of features of the metabolic syndrome when additionally adjusting for systolic blood pressure as a continuous variable.

Conclusion

Increasing severity of metabolic syndrome was associated with increasingly compromised structure and function of the heart. This association was independent of Framingham risk score for indirect indices of diastolic dysfunction but not systolic dysfunction, and was not explained by blood pressure level.  相似文献   

14.
Studying the natural history of coronary artery disease could provide a frame of reference for prognosis and appraisal of treatment for patients having this disease. We studied a total of 465 consecutive patients with angiographically significant coronary artery disease, defined as greater than 50% stenosis in at least one principal artery, who were followed with medical treatment only from 1 to 7 years. Excluding patients with left main coronary disease, there were 73 deaths, of whom 63 were cardiac. The 5-year cumulative survival rates were 72% for the entire group, 87% for single vessel disease, 73% for double vessel disease and 51% for triple vessel disease. In single vessel disease, patients with left anterior descending artery involvement tended to have higher mortality. In double vessel disease, survival was worse with the combination of left anterior descending and right coronary artery involvements than the other 2 combinations. A history of myocardial infarction was not significantly different from angina in 5-year survival rate. Nevertheless, an abnormal Q-wave in ECG was associated with lower survival. History of hypertension and electrocardiographic left ventricular hypertrophy did not affect survival. While congestive heart failure, abnormal resting LVEDP and left ventricular asynergy were all associated with reduced survival. The left ventricular ejection fraction had highly prognostic value, only 42% of patients survived with ejection fraction less than 0.3 at the end of 5 years after angiography.  相似文献   

15.

Aims

To determine the frequency, characteristics and risk factors of cardiac device infections in the Isala Hospital.

Methods

We retrospectively studied all patients who underwent cardiac device procedures performed in the cardiac catheterisation lab and the operating room from 2010 to 2012. All patients who developed a cardiac device infection were reviewed for its characteristics.

Results

31/2026 patients developed a cardiac device infection (1.5 %). One (3.2 %) patient died within 30 days of hospitalisation. Device infection rates for procedures in the catheterisation lab and operating room were similar (p = 0.60). Positive cultures were present in 27/31 (87 %) cases. These consisted predominantly of micro-organisms that are part of the skin flora (84 %). The mean time between device procedure and infection was 14 ± 21 months (range 0–79). Cardiac device infection was significantly associated with device revision, (65 % were revisions in patients with device infection vs. 30 % revisions in patients without device infection, p = 0.011) and placement of a left ventricular lead in pacemaker implantations (59 % of patients with vs. 51 % of patients without device infection, p < 0.001).

Conclusion

The frequency of cardiac device infection was 1.5 % with a mortality of 3.2 % within 30 days, which is lower compared with other registries. Cardiac device infections were associated with device revisions and placement of left ventricular leads in pacemaker implantations.  相似文献   

16.
Cell delivery via the retrograde coronary route boasts less vessel embolism, myocardial injury, and arrhythmogenicity when compared with those via antegrade coronary administration or myocardial injection. However, conventional insertion into the coronary sinus and consequent bleeding complication prevent its application in small animals. To overcome the complication of bleeding, we described a modified coronary retroinfusion technique via the jugular vein route in rats with myocardial infarction (MI). A flexible wire with a bent end was inserted into the left internal jugular vein and advanced slowly along the left superior vena cava. Under direct vision, the wire was run into the left cardiac vein by rotating the wire and changing the position of its tip. A fine tube was then advanced along the wire to the left cardiac vein. This modified technique showed less lethal hemorrhage than the conventional technique. Retroinfusion via transjugular catheter enabled efficient fluid or cell dissemination to the majority areas of the free wall of the left ventricle, covering the infarcted anterior wall. In conclusion, transjugular cardiac vein catheterization may make retrocoronary infusion a more safe and practical route for delivering cell, drug, and gene therapy into the infarcted myocardium of rats.  相似文献   

17.
The lack of suitable target vessels remains a challenge for aortocoronary bypass grafting in end-stage coronary heart disease. This study aimed to investigate the arterialization of cardiac veins as an alternative myocardial revascularization strategy in an experimental long-term model in pigs. Selective retrograde perfusion of a coronary vein (aorta to coronary vein bypass, retrobypass) before ligation of the ramus interventricularis paraconalis (equivalent to the left anterior descending artery in humans) was performed in 20 German Landrace pigs (Sus scrofa domestica). Retroperfusion of the left anterior descending vein was performed in 10 pigs (RP+) but not in the other 10 (RP-), and the vena cordis magna was ligated (L+) in 5 pigs in each of these groups but left open (L-) in the remaining animals. Hemodynamic performance (for example, cardiac output) was significantly better in the group that underwent selective retroperfusion with proximal ligation of vena cordis magna (RP+L+; 4.1 L/min) compared with the other groups (RP+L-, 2.5 L/min; RP-L+, 2.2 L/min; RP-L-, 1.9 L/min). Long-term survival was significantly better in RP+L+ pigs (112±16 d) than in all other groups. Histologic follow-up studies showed significantly less necrosis in the RP+L+ group compared with all other groups. Venous retroperfusion is an effective technique to achieve long-term survival after acute occlusion of the left anterior descending artery in a pig model. In this model, proximal ligation of vena cordis magna is essential.  相似文献   

18.
A 40-year-old woman presented with dyspnoea, chest pain and fatigue. Her medical history was unremarkable. An early systolic ejection murmur was heard in the 3D left inter-costal space. Chest X-ray revealed normal cardiothoracic ratio with an anomalous vessel adjacent to the left pulmonary hilum. Echocardiography and exercise tolerance test were normal. Right heart catheterisation revealed normal pulmonary pressures with normal cardiac output. CT scan and MRI of the thorax were diagnostic for an aberrant pulmonary venous connection between the left lower lobe pulmonary vein and the left brachiocephalic vein without atrial septal defect. She was treated conservatively and remained well.  相似文献   

19.
The diagnosis, angiographic evaluation and surgical treatment by aortocoronary vein bypass are described in a 3½-year-old girl with anomalous origin of the left coronary artery from the pulmonary artery. The anomaly had resulted in cardiac dilatation, diminished left ventricular contractility, an aneurysm of the left ventricular free wall and mitral regurgitation.At the postoperative cardiac catheterization the graft was demonstrated to be patent, but a significant proportion of the flow to the left coronary artery was derived from anastomotic connections with the right coronary artery. The most striking evidence of improvement was obtained from the left ventricular volume studies which showed that the end systoiic volume had decreased from 85 to 49 ml./m.2 with an increase in ejection fraction from 0.39 to 0.62, suggesting enhanced left ventricular contractility after surgery.The patient continues to do well and is free from symptoms.  相似文献   

20.
Seven per cent of a sample group of civil service employees were found to have diagnosable heart disease. The diagnosis was made on the basis of a complete physical examination and history taken by a specialist in internal medicine and/or heart disease. In addition a questionnaire form related to symptoms of heart disease was filled out by the patient, and various laboratory tests were made. As a technique in cardiac case-finding, the electrocardiogram was the best single device. Of all the cases of heart disease in this survey 65 per cent were detected from tracings obtained by using all 12 leads, and 57 per cent if only the three standard limb leads were taken; but of the presumably normal persons, 13 per cent would be erroneously suspected of possible heart disease by this technique. Heart disease was detected in 50 per cent of the diagnosed cases on the basis of answers to three of the questions in the questionnaire. Eighteen per cent of normal persons would also have been suspected of having heart disease by this case-finding device. Although the survey reported did not develop a simple cardiac case-finding technique, the data presented indicated that a questionnaire history-form, if judiciously used and evaluated, may be of value to physicians who examine large numbers of patients who are unwilling to submit to a complete cardiac evaluation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号