共查询到20条相似文献,搜索用时 15 毫秒
1.
Ian Brotherick Brian K. Shenton Brian Angus Ian S. Waite Charles H. W. Horne Thomas W. J. Lennard 《Cancer immunology, immunotherapy : CII》1995,41(5):280-286
In order to assess the specificity of biotinylated anti-c-erbB-3 antibody, screening was performed on a series of tumour cell lines and lymphocytes. Staining was found to be consistent, with good reproducibility. Twenty-nine consecutive breast cancer samples were obtained from women treated with tamoxifen and undergoing elective mastectomy. Twenty-eight invasive ductal carcinomas and 1 DCIS were stained for c-erbB-3 expression: 2 were grade I (Bloom and Richardson), 15 grade II, and 11 grade III tumours, 1 being unclassified; 16 were axillary node positive and 10 node negative; in 2 cases no nodes were sampled. Tumours examined by flow cytometry were stained with cytokeratin FITC antibody and the cytokeratin-positive population gated. Using Mann-Whitney analysis no association was seen between c-erbB-3 expression and Bloom and Richardson grade or axillary node status. In the tumour samples c-erbB-3 expression was found to show an association with EGF-R (P=0.021r
2=0.16), PgR (P=0.02,r
2=0.16), c-myc (P<0.0001,r
2=0.5), c-jun (P=0.001,r
2=0.4) and c-fos (P=0.001,r
2=0.5) but not with c-erbB-2 (P=0.2,r
2=0.06), ER (P=0.4,r
2=0.02) or p53 1801 (P=0.05,r
2=0.2). Expression of c-erbB-3 may not be an independent marker of prognosis, but it is associated with other markers of poor prognosis and early cellular events linked with aberrant growth and differentiation.This study was supported by The North of England Cancer Research Campaign 相似文献
2.
Flow cytometry is an advanced technology for efficient, rapid, specific and multi-parameter analysis of single cells in various basic research fields including cytobiology, immunology, genetic, hematology and other basic research. Beclin-1 protein is an important indicator in monitoring autophagic activity. However, quantitative flow cytometry had been rarely reported till now to be applied in the detection of Beclin-1 expression. The present study was aimed to establish a flow cytometric method for quantitative detection of Beclin-1 expression by employing the autophagy inhibitor 3-methyladenine as the control. A multi-parameter optimal method for Beclin-1 protein staining is as follows. 2 % bovine serum albumin in phosphate buffered saline was used for sample block. Concentration of primary antibody was 0.004 μg/μL. Samples were incubated at room temperature (25 °C) for 30 min. The prepared samples had better to be detected immediately or to be stored at 4 °C and detected within 6 h, otherwise the samples should be fixed in 1 % paraformaldehyde storing at 4 °C and detected within 3 d. Furthermore, we employed the immunohistochemistry to validate the method in vivo, the results confirmed flow cytometric method. The established flow cytometric analysis for Beclin-1 protein has the advantage of simpleness, speediness, sensitivity and reproducibility. 相似文献
3.
J. Doležel S. Lucretti 《TAG. Theoretical and applied genetics. Theoretische und angewandte Genetik》1995,90(6):797-802
Flow cytometric analysis has been performed on chromosomes isolated from formaldehyde-fixed root tips in a Vicia faba (2n = 12) line with a standard (wild-type) karyotype and in six V. faba translocation lines with reconstructed karyotypes. The resolution of individual chromosome types on histograms of chromosome fluorescence intensity (flow karyotypes) depended on the type of fluorochrome used for chromosome staining. The highest degree of resolution was achieved with 4,6-diamidino-2-phenylindole (DAPI). The lower resolution obtained after staining with mithramycin A (MIT) and propidium iodide (PI) was probably due to the sensitivity of these stains to changes in chromatin structure induced by formaldehyde fixation. After the staining with DAPI, only 1 chromosome type could be discriminated in the line with a standard karyotype. In the translocation lines, the number of chromosome types resolved on flow karyotypes ranged from 2 in the G and the ACB lines to all (6) chromosome types in the EFK and EF lines. Refined flow karyotyping permitted the sorting of a total of 15 different chromosome types from five of the translocation lines. It is expected that flow sorting of chromosomes from reconstructed karyotypes will become a powerful tool in the study of nuclear genome organisation in V. faba. 相似文献
4.
Miklós Emri László Balkay Zoltán Krasznai Lajos Trón Teréz Márián 《European biophysics journal : EBJ》1998,28(1):78-83
To prove the general applicability of a recently published flow cytometric method to determine the membrane potentials of
cells on the absolute (mV) scale, the validity of the premises involved were analyzed individually. Experimental evidence
was given for bis-oxonol, the applied membrane potential indicator being a Nernstian dye. The results of special measurements
proved that extracellular dye concentrations were not affected by cellular dye uptake under the applied experimental conditions
and that the dye content of the suspending medium did not contribute directly to the measured cellular fluorescence. A direct,
membrane-potential-independent contribution of the extracellular dye to cellular fluorescence was also found to be negligible,
as membrane potential values of the same type of cells evaluated from measurements in the presence of different extracellular
oxonol concentrations were very close to each other. The transmembrane potential of B lymphoid JY cells was measured by the
method as a function of cell density in the tissue culture. Cells isolated during the log phase of growth displayed a –40±4
mV membrane potential. At a high density of the culture (plateau phase), a significant increase of the membrane potential
to –61±3 mV was observed and a medium value of –47±3.5 mV was measured at an intermediate density of the cells. Our observation
indicates that nonadherent cells can also be hyperpolarized when optimal growth conditions are terminated.
Received: 14 April 1998 / Revised version: 22 June 1998 / Accepted: 16 July 1998 相似文献
5.
Phenotypic biomonitoring using multivariate flow cytometric analysis of multi-stained microorganisms 总被引:2,自引:0,他引:2
Wikström P Johansson T Lundstedt S Hägglund L Forsman M 《FEMS microbiology ecology》2001,34(3):187-196
A new method for monitoring phenotypic profiles of pure cultures and complex microbial communities was evaluated. The approach was to stain microorganisms with a battery of fluorescent dyes prior to flow cytometry analysis (FCM) and to analyse the data using multivariate methods, including principal component analysis and partial least squares. The FCM method was quantitatively evaluated using different mixtures of pure cultures as well as microbial communities. The results showed that the method could quantitatively and reproducibly resolve both populations and communities of microorganisms with 5% abundance in a diverse microbial background. The feasibility of monitoring complex microbial communities over time during the biodegradation of naphthalene using the FCM method was demonstrated. The biodegradation of naphthalene occurred to differing extents in microcosms representing three different types of aromatic-contaminated groundwater and a sample of bio-basin water. The FCM method distinguished each of these four microbial communities. The phenotypic profiles were compared with genotypic profiles generated by random-amplified polymorphic DNA analysis. The genotypic profiles of the microbial communities described only the microbial composition, and not their functional change, whereas the phenotypic profiles seemed to contain information on both the composition and the functional change of the microorganisms. Furthermore, event analysis of the FCM data showed that microbial communities with initially differing compositions could converge towards a similar composition if they had a capacity for high levels of degradation, whereas microbial communities with similar initial compositions could diverge if they differed in biodegrading ability. 相似文献
6.
Fundamentals of flow cytometry 总被引:4,自引:0,他引:4
Flow cytomelers arc instruments that arc used primarily to measure the physical and biochemical characteristics of biological
particles. This technology is used to perform measurements on whole cells as well as prepared cellular constituents, such
as nuclei and organelles. Flow cytomcters are investigative tools for a broad range of scientific disciplines because they
make measurements on thousands of individual cells/ particles in a matter of seconds. This is a unique advantage relative
to other detection instruments that provide bulk particle measurements. Flow cytomety is a complex and highly technical field;
therefore, a basic understanding of the technology is essential for all users. The purpose of this article is to provide fundamental
information about the instrumentation used for flow cytometry as well as the methods used to analyze and interpret data. This
information will provide a foundation to use flow cytometry effectively as a research tool. 相似文献
7.
K. Arumuganathan J. P. Slattery S. D. Tanksley E. D. Earle 《TAG. Theoretical and applied genetics. Theoretische und angewandte Genetik》1991,82(1):101-111
Summary A procedure for the preparation of tomato chromosome suspensions suitable for flow cytometric analysis is described. Rapidly growing cell suspension cultures of Lycopersicon esculentum cv VFNT cherry and L. pennellii LA716 were treated with colchicine to enrich for metaphase chromosomes. Metaphase indices between 20 and 35% were routinely obtained when cultures were exposed to 0.1% colchicine for 15–18 h after 2 days of subculture. Mitotic cells were isolated by brief treatment with cell wall digesting enzymes in a medium with low osmolarity (325 mOsm/kg of H52O). The low osmolarity medium was needed to avoid the chromosome clumping and decondensation seen in standard media. Suspensions of intact chromosomes were prepared by lysing swollen protoplasts in various buffers (MgSO4, polyamines, hexylene glycol, or KCl-propidium iodide) similar in contents to the buffers used to isolate mammalian chromosomes. For univariate flow cytometric analysis, chromosome suspensions were stained with a fluorescent DNA-binding stain (propidium iodide, Hoechst 33258, mithramycin, or chromomycin A3) and analyzed using an EPICS flow cytometer (Profile Analyzer or 753). Peaks for the chromosomes, chromatids, clumps of chromosomes, nuclei, and fluorescent debris were seen on a histogram of log of fluorescence intensity, and were confirmed by microscopic examination of the objects collected by flow-sorting. Chromosome suspensions prepared in MgSO4 buffer have the highest frequency of intact chromosomes and the least fluorescent cellular debris. Peaks similar to theoretical univariate flow karyotypes of tomato chromosomes were seen on the observed univariate flow karyotypes, but were not as well resolved. Bivariate flow analysis of tomato chromosome suspension using double-stain combination, Hoechst 33258 and chromomycin A3, and two laser beams showed better resolution of some chromosomes. 相似文献
8.
A stochastic model for interpreting BrdUrd DNA FCM-derived data is proposed. The model is based on branching processes and describes the progression of the DNA distribution of BrdUrd-labelled cells through the cell cycle. With the main focus on estimating the S phase duration and its variation, the DNA replication rate is modelled by a piecewise linear function, while assuming a gamma distribution for the S phase duration. Estimation of model parameters was carried out using maximum likelihood for data from two different cell lines. The results provided quite a good fit to the data, suggesting that stochastic models may be a valuable tool for analysing this kind of data. 相似文献
9.
A rapid, simple and sensitive flow cytometric system for detection of Plasmodium falciparum. 总被引:2,自引:0,他引:2
Atsuko Saito-Ito Yasumasa Akai Shenyi He Mikio Kimura Masato Kawabata 《Parasitology international》2001,50(4):249-257
We have established a rapid, simple and sensitive flow cytometric system for the detection of Plasmodium falciparum that involves lysing erythrocytes and staining parasites at the same time using a newly developed hemolysing and staining solution containing dodecyl methyl ammonium chloride and acridine orange. In this system, freed parasites of P. falciparum could be plotted separately from erythrocyte ghosts, white blood cells and platelets on the two-dimensional scattergram of forward-angle light scatter and green fluorescence by flow cytometry with an argon laser. It took only 2–3 min per sample to obtain the scattergram and analyze the data, including the time of sample preparation for flow cytometric analysis. Sample preparation with this method does not require any difficult handling procedures. The threshold of parasite detection was almost equal to that of microscopic examination for cultured P. falciparum. The results of drug-susceptibility assays using this system were also almost identical to those obtained using microscopic examination. In this system, parasites at different erythrocytic stages could be easily distinguished. This system must prove useful and practical for basic laboratory studies of P. falciparum including those requiring the differential measurement of parasites at specific erythrocytic stages. 相似文献
10.
《Process Biochemistry》2014,49(4):554-562
Rhodosporidium toruloides NCYC 921 batch growth was monitored as a means to evaluate the yeast biomass potential as a source for the production of carotenoids and other lipids.Carotenoid content, cell viability and size were assessed by multiparameter flow cytometry. The saponifiable lipid fraction was assayed by gas–liquid chromatography.The carotenoid production increased during the stationary phase, reaching 78 μg/g while the total fatty acid content attained 32% (w/w) at the end of the fermentation. The fatty acid profile was suitable for biodiesel purposes.As the yeast cells entered the stationary phase, the proportion of cells with depolarised mitochondrial membrane and cells with permeabilised cytoplasmic membrane increased, attaining 65% and 14%, respectively. Nevertheless, a high proportion of cells (82%) showed esterase activity.These results demonstrated that flow cytometry can be a powerful at-line technique to monitor the total carotenoids and cell viability during the yeast growth, being useful for the yeast process optimisation at lab and pilot scales. 相似文献
11.
Carbohydrate binding underlies many cell recognition events. Here, we describe a multiplexed glyco-bead array method for determining the carbohydrate-binding specificities of plant lectins using a bead-based flow cytometric analysis. N-glycans including high mannose, hybrid, and complex types and O-glycans from glycoproteins were immobilized on multiplexed beads, and the specificities of 13 kinds of sugar chains were monitored within 2 h in a single reaction. This strategy is easy, rapid, reproducible, and suitable for small samples and allows the reliable and simultaneous elucidation of sugar-binding properties under identical conditions. 相似文献
12.
Sara Yossefi Yitzchak Oschry Lawrence M. Lewin 《Molecular reproduction and development》1994,37(1):93-98
In this study we have used acridine orange staining, as described by Evenson (1990), to follow changes in DNA packaging as they occur in hamster spermatozoa which have left the testis and are undergoing maturation in the epididymis. Measurement of the green and red fluorescent intensities of hamster sperm nuclei by flow cytometry demonstrated a decrease in acridine orange binding to DNA as sperm made their way from proximal corpus epididymis to the vas deferens. Using sperm from the cauda epididymis of the mature hamster as the standard, a method was developed for estimating the % of cells in a given sample that have matured with regard to DNA packaging. Staining with bromobimane was used to determine the extent of sulfhydryl oxidation in the nuclei. It was seen that sulfhydryl oxidation occurred mainly in the cauda epididymis whereas another process in chromatin condensation occurred earlier, during sperm passage through the caput epididymis. This earlier process could be mimicked by incubating sperm nuclei with alkaline phosphatase, suggesting that it consists of removal of phosphate in protamine. © 1994 Wiley-Liss, Inc. 相似文献
13.
Development of a flow cytometric assay to study glucocorticoid receptor-mediated gene activation in living cells 总被引:2,自引:0,他引:2
A flow cytometry-based reporter gene assay was developed and utilized to measure glucocorticoid receptor (GR)-mediated gene activation at the single cell level in living cells. A reporter gene was generated that contains two copies of the glucocorticoid response element and an E1b TATA box upstream of a destabilized enhanced green fluorescent protein. Glucocorticoid activation of the reporter gene in Cos-1 and HTC cell lines was measured in vivo by flow cytometry and was shown to be dose dependent, leading to an increase in total fluorescence of the cell population. Flow cytometric analysis indicated this increase in total fluorescence per sample resulted from an increase in the number of cells expressing the activated green fluorescent protein (GFP) reporter as well as an overall increase in the mean GFP fluorescence within cells. Activation of reporter gene activity was time dependent occurring as early as 1-2h after dexamethasone addition. Activation of the reporter gene was specific as it exhibited different sensitivities to a range of glucocorticoids and activation could be blocked with glucocorticoid receptor antagonists. Coexpression of the coactivator SRC-1a or P65 subunit of NF-kappa B with GR led to enhancement or repression, respectively. Taken together, these data suggest the reporter-based flow cytometry assay is an effective method for analyzing glucocorticoid receptor-mediated gene expression at the single cell level in living cells. 相似文献
14.
目的探讨用流式细胞术进行细菌计数。方法检测被链球菌α-34抑止而死亡的化脓性链球菌32309-2数量。结果实验管MFI值明显比对照管强,实验管本身的MFI强度随着时间的增加而增强,而对照管则基本上变化不是很大;到24h后,对照管MFI已达1.01,而对照管还是维持在0.4左右,两者T检验P〈0.01。结论用PI染色,可用流式细胞术检测死亡细菌。结果可靠,用时短,极大地简化了实验步骤。 相似文献
15.
Günther S Hübschmann T Rudolf M Eschenhagen M Röske I Harms H Müller S 《Journal of microbiological methods》2008,75(1):127-134
Analysis of environmental bacteria on the single cell level often requires fixation to store the cells and to keep them in a state as near life-like as possible. Fixation procedures should furthermore counteract the increase of autofluorescence, cell clogging, and distortion of surface characteristics. Additionally, they should meet the specific fixation demands of both aerobically and anaerobically grown bacteria. A fixation method was developed based on metal solutions in combination with sodium azide. The fixation efficiencies of aluminium, barium, bismuth, cobalt, molybdenum, nickel, and tungsten salts were evaluated by flow cytometric measurement of the DNA contents as a bacterial population/community stability marker. Statistical equivalence testing was involved to permit highly reliable flow cytometric pattern evaluation. Investigations were carried out with pure cultures representing environmentally important metabolic and respiratory pathways as controls and with activated sludge as an example for highly diverse bacterial communities. A mixture of 5 mM barium chloride and nickel chloride, each and 10% sodium azide was found to be a suitable fixative for all tested bacteria. The described method provided good sample stability for at least 9 days. 相似文献
16.
Flow cytometry is now being used more frequently to determine sperm functional characteristics during semen assessment for artificial insemination. With this methodology, viable and potentially functional cells are detected as unstained events differentiated from non-sperm events through their light-scattering characteristics. However, it can be shown mathematically that identification of sperm on the basis of light scatter leads to significant overestimation of unstained viable cells and underestimation of responding cells in tests of sperm function (subpopulations expressing different fluorescence patterns). We have developed a simple and cost-efficient flow cytometric approach for identifying non-sperm particles that can be carried out in parallel with functional assessments. Our method is based on the sperm's osmotic intolerance. Diluted in water, lethal osmotic shock causes major damage to the cell membranes, and all sperm will stain with propidium iodide (PI). Particulate material which is not PI-positive can then be quantitatively evaluated by FACS analysis and the results substituted in mathematical equations to provide true values for sperm counts and subpopulations. In practical tests, the percentage of non-sperm particles determined by this technique was closely comparable to the figure obtained either by SYBR14®/PI staining or by PI/CFDA staining. As well as being valuable with respect to tests of sperm function, the procedure is also suitable for obtaining accurate sperm counts during routine semen evaluation. 相似文献
17.
Joanne E. Collins Patricia C. Ellis Angela T. White Antonia E.G. Booth Claire E. Moore Mark Burman Robert W. Rees Anthony M. Lynch 《Mutation Research - Genetic Toxicology and Environmental Mutagenesis》2008,654(1):76-81
We have evaluated the performance of the prototype In Vitro MicroFlow® Kit (Litron Laboratories), which offers a flow cytometric method for scoring micronuclei (MN). This method uses sequential staining to differentiate MN from chromatin fragments derived from apoptotic or necrotic cells. Data were generated using the genotoxins methylmethane sulphonate (MMS), dimethylbenzanthracene (DMBA) and vinblastine, and the non-genotoxins dexamethasone and staurosporine, which are known to induce apoptosis in vitro. The results obtained with these agents were compared with conventional microscopy.For short-duration exposures (3–4 h) both manual and flow methodologies demonstrated good concordance, with concentration-related increases in the percentage of MN for MMS, DMBA and vinblastine. Statistically significant increases were observed at ≥20 and 40 μg/mL, for manual and flow analysis, respectively, for MMS; at 0.5 and 0.75 μg/mL for DMBA; and at 0.035 and 0.04 μg/mL, respectively, for vinblastine. Dexamethasone showed clear negative responses by manual and flow cytometric analysis, with comparable results for both methodologies (all <1.7-fold compared with concurrent vehicle controls). Data for staurosporine, however, were less consistent showing significantly higher flow cytometric MN frequencies compared with those seen after manual analysis.Continuous (24 h) treatments were also conducted with MMS, vinblastine, dexamethasone and staurosporine. There was good concordance between the methodologies for MMS, staurosporine and vinblastine. However, dexamethasone generated discordant results, i.e. microscopic analysis was clearly negative at all doses tested, whereas flow cytometry produced significant increases in MN frequency (up to 8.1-fold at 100 μg/mL compared with the concurrent vehicle control).The inconsistencies observed between flow cytometry and standard microscopy, and the differences in assay sensitivity, particularly for apoptosis-inducing compounds, suggest that the prototype In Vitro MicroFlow® Kit requires further refinement. Studies to investigate new parameters to address these issues are now under way and will be reported separately. 相似文献
18.
Light scattering properties of hybridoma cells were examined with flow cytometry. Viable and dead cells form two distinct populations. The distribution of the two populations changes during a batch culture. the concentration of dead cells measured by flow cytometry correlates well to that measured by hemacytometer. The distribution based on small-angle light scattering is similar to the distribution based on volume as measured by Elzone particle counter. It thus appears that viable cells form the population with a larger mean cell volume. The results also indicate that the volume of viable cells decreases during the cultivation while that of dead cells remains relatively constant. 相似文献
19.
Steven M. Bryce Svetlana L. Avlasevich Jeffrey C. Bemis Magdalena Lukamowicz Azeddine Elhajouji Freddy Van Goethem Marlies De Boeck Dominiek Beerens Hilde Aerts Jacky Van Gompel Joanne E. Collins Patricia C. Ellis Angela T. White Anthony M. Lynch Stephen D. Dertinger 《Mutation Research - Genetic Toxicology and Environmental Mutagenesis》2008,650(2):181-195
An international, multi-lab trial was conducted to evaluate a flow cytometry-based method for scoring micronuclei in mouse lymphoma L5178Y cells [S.L. Avlasevich, S.M. Bryce, S.E. Cairns, S.D. Dertinger, In vitro micronucleus scoring by flow cytometry: differential staining of micronuclei versus apoptotic and necrotic chromatin enhances assay reliability, Environ. Mol. Mutagen. 47 (2006) 56–66]. A reference laboratory investigated the potential of six chemicals to induce micronuclei—the genotoxicants mitomycin C (MMC), etoposide (ETOPO), and vinblastine (VB), and the non-genotoxicants sucrose (SUC), staurosporine (STS), and dexamethasone (DEX). The latter two non-genotoxicants were selected as extreme challenges to the assay because of their potent apoptogenic activity. Three collaborating laboratories were supplied with prototype In Vitro MicroFlow™ kits, and each was assigned one genotoxicant and one non-genotoxicant. Cells were treated continuously for 24 h over a range of concentrations up to 5 mg/ml, or overtly cytotoxic concentrations. Micronuclei were scored via standard microscopy and flow cytometry. In addition to enumerating micronucleus frequencies, a cytotoxicity measurement that is simultaneously acquired with the flow cytometric micronucleus scoring procedure was evaluated (Flow-NBR). With this method, latex particles served as counting beads, and facilitated relative survival measurements that exclude the presence of dead/dying cells. For comparison purposes, additional cytotoxicity endpoints were measured, including several that are based on cell number, and others that reflect compromised membrane integrity, including dye permeability and/or phospholipid distribution. Key findings for this set of compounds include the following: (1) significant discrepancies in top concentration selection were found when cytotoxicity measurements were based on different methods, with the Flow-NBR approach tending to be the most sensitive, (2) both microscopy- and flow cytometry-based scoring methods detected concentration-dependent micronucleus formation for the three genotoxic agents studied, with good agreement between the reference laboratory and the collaborating laboratories, and (3) whereas flow cytometric analyses showed no significant increases for the non-genotoxicants when top concentration selection was based on Flow-NBR, significantly elevated micronucleus frequencies were observed for concentrations that were chosen based on less-sensitive cytotoxicity assays. Collectively, these results indicate that rapid assessment of genotoxicity can be accomplished with a relatively simple flow cytometric technique, and that the scoring system is transferable across laboratories. Furthermore, a concurrent assessment of cytotoxicity, Flow-NBR, may help reduce the occurrence of irrelevant positive results, as it may represent a more appropriate means for choosing top concentration levels. Finally, the data presented herein reinforce concerns about the manner in which cytotoxicity limits are described in guidance documents, since these recommendations tend to cite fixed cut-off values without reference to methodology. 相似文献
20.
The purpose of semen quality evaluation is to predict the fertility potential of the sample in an objective, rapid and inexpensive manner. However, utilization of sperm quality biomarkers such as ubiquitin and lectin Arachis hypogaea agglutinin (PNA) for flow cytometric semen evaluation might eliminate the need for visual assessment by microscopy. Herein, we demonstrate a robust ubiquitin and PNA-based semen evaluation conducted on a simple, easy to operate, dedicated sperm flow cytometer, EasyCyte Plus (IMV Technologies, L'Aigle, France). Semen samples were collected periodically from two dairy bulls, which were subjected to temporary scrotal insults to induce variable semen quality. Samples were labeled with fluorescently-conjugated anti-ubiquitin antibodies (bind exclusively to the surface of defective sperm) and lectin PNA (binds to acrosomal surface in prematurely capacitated and acrosome-damaged sperm). Fluorescent properties of the samples were measured with a conventional flow cytometer (Becton Dickinson FACScan; Becton Dickinson Corp., Franklin Lakes, NJ, USA) and by the EasyCyte (IMV Technologies) instrument. Data from the two flow cytometers were positively correlated for the percentage of PNA-positive sperm with a damaged acrosome (r = 0.47; P < 0.001) and the percentage of ubiquitin-positive, defective sperm (r = 0.68; P < 0.001). Relative intensities of ubiquitin-induced fluorescence in cells with high ubiquitin levels were also positively correlated (r = 0.90). The proportion of sperm with abnormal morphology was positively correlated with ubiquitin-induced fluorescence measured by EasyCyte (IMV Technologies) (r = 0.63; P < 0.001). These observations provided a rationale for the adaptation of a dual ubiquitin-PNA sperm quality assay for flow cytometric semen evaluation. 相似文献