首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 983 毫秒
1.
A free gracilis muscle transfer with skin graft was performed for reconstruction of a type IIIB lower extremity traumatic wound with acute exposure of the distal tibia fracture site and an extensive soft-tissue wound. The free muscle flap failed from a venous thrombosis that was recognized 12 hours postoperatively, and reexploration revealed extensive venous thrombosis throughout the lower leg. The flap was salvaged by direct catheter administration of heparin into the vena comitans of the gracilis artery, which bathed the newly repaired venous anastomosis with an anticoagulating dose of heparin without systemic elevation of the patient's PTT. Ultimate full flap survival and wound healing ensued.  相似文献   

2.
The effectiveness of localized retrograde coronary venous perfusion (RCVP) in preventing or reversing myocardial ischemia after acute ligation of a coronary artery is described. Ten domestic pigs (Group I) underwent aorto left anterior coronary vein grafting with RCVP at systemic pressure. In another set of ten pigs (Group II), the coronary vein was similarly grafted, but the proximal end of the graft was perfused with oxygenated blood by means of an external pump at reduced pressure and flow. In both groups, RCVP successfully reversed the mechanical or electrical effects produced by 2 to 5 minutes of acute arterial ligation. After several hours, Group I animals showed evidence of acute ischemia and developing infarction. Group II animals, however, were maintained for 7 hours or more with regional RCVP and no evidence of ischemia. Retrograde coronary venous perfusion at reduced pressure may be more effective than perfusion at systemic pressure in providing myocardial blood flow.  相似文献   

3.
OBJECTIVE--To evaluate the efficacy and safety of two subcutaneous prophylactic regimens for postoperative deep vein thrombosis after total hip replacement. DESIGN--Prospective open randomised multicentre trial. SETTING--28 European departments of orthopaedic surgery. INTERVENTION--All patients had bilateral phlebography 10 days after surgery. 31 patients receiving low molecular weight heparin and 29 receiving unfractionated heparin were excluded from the efficacy analysis for various reasons. PATIENTS--349 patients undergoing total hip replacement between September 1988 and May 1989. 174 patients received subcutaneously a low molecular weight heparin (Fraxiparine) with anti-factor Xa activity of 41 IU/kg/day for three days, then 62 IU/kg/day from day 4 to day 10. 175 patients received subcutaneous unfractionated heparin at intervals of eight hours; doses were adjusted to maintain the activated thromboplastin time at two to five seconds above control values. MAIN OUTCOME MEASURE--Total incidence of deep vein thrombosis and incidence of proximal deep vein thrombosis on bilateral phlebography. RESULTS--The total incidence of deep vein thrombosis was 16% in patients receiving unfractionated heparin and 12.6% in patients receiving low molecular weight heparin (p = 0.45), and the incidence of thrombosis of the proximal veins was 13.1% and 2.9% respectively (p less than 0.001). Four patients receiving unfractionated heparin and one receiving low molecular weight heparin developed pulmonary embolism. The incidence of bleeding complications was low and comparable in the two groups. CONCLUSION--Low molecular weight heparin is at least as effective as unfractionated heparin in preventing deep vein thrombosis and is more effective at preventing thrombosis of the proximal veins in patients undergoing hip replacement. Low molecular weight heparin is not more likely to cause bleeding complications and is simpler to give than unfractionated heparin.  相似文献   

4.
In the treatment of venous insufficiency unsuitable for surgical correction in replanted digits, a small ungual window was surgically created to infiltrate subcutaneous heparin in the congested digit. The initial heparin dose was 1000 units. This dose made possible a continuous bleeding during 24 to 48 hours, solely through the ungual window. Further doses were applied based on the degree of congestion of the replanted digit, but usually it was necessary to infiltrate up to 500 units of heparin every 24 to 48 hours until vascular stability was achieved. Three patients were treated with this technique. One opted for quitting the treatment. A replanted thumb suffered venous congestion on the seventh postoperative day and was treated with local subcutaneous heparin for 3 days. A replanted fingertip suffered venous thrombosis 24 hours after surgery and was treated likewise for 18 days. In these two patients, success was attained. Blood transfusions were carried out in the latter two, and none had any systemic changes in partial thromboplastin or thrombin time. This treatment is based on the mechanism of action of heparin at high doses but applied only to the congested segment. Besides their anticoagulant effect through antithrombin, high doses of heparin slow platelet aggregation, may induce angiogenesis, and have a longer-than-normal half-life. With the above technique, heparin has been applied to the congested segment at an approximate dose of 33,000 to 40,000 units/kg, and continuous bleeding solely through the ungual window for 24 to 48 hours has been achieved, which has allowed us to save two replanted segments with no complications at all. This method may offer another alternative for the medical treatment of venous insufficiency in replanted segments.  相似文献   

5.
In an attempt to decrease a 10 to 15 percent vascular thrombosis rate leading to graft occlusion, low-dose human-grade heparin was studied to determine if carefully monitored intravenous therapy would increase 7-day patency in a known potent thrombosis model. In New Zealand white rabbits, the type of infusate administered intravenously, either saline (30 animals) or heparin (35 animals), was selected at random after completing a 2-mm arterial inversion graft in the femoral artery. A 72-hour infusion was used in all animals; the control group received sterile saline and the experimental group received a heparin infusion at 45 microliters per hour after a 500-unit bolus. All grafts in both groups were patent at the time of groin closure. Patency in the heparin-perfused group was 67 percent (24 of 35) as compared to 19 percent (6 of 30) in the control group (p less than 0.05) 1 week postoperatively. Scanning electron microscopy showed significantly less dense fibrin deposition and a decrease in the number of aggregated platelets in the heparin-perfused grafts. Partial tissue thromboplastin time values in the experimental group ranged between 55 and 75 seconds (control 20 to 25 seconds). We have shown that heparin, an inexpensive and readily available agent, maintains 1-week microarterial patency and results in few complications in a reliable, reproducible, and versatile thrombosis model. The clinical ramifications of using an antiplatelet agent that diminishes fibrin deposition in microsurgery are apparent.  相似文献   

6.
The objective of this study was to describe the uncommon connections between cardiac veins, alternative pathways within cardiac venous circulation and complex variability of the venous system in the heart ventricles. The study was carried out on 30 adult New Zealand White rabbits. The arrangement of the cardiac veins was studied by using the corrosion casts prepared with the Spofacryl® and by perfusion of coloured latex. The presence and organization of principal veins of the heart ventricles was relatively constant with a great variability in the mode of opening and forming a common trunk. The highest variations were observed in the region of the paraconal interventricular vein, the left and right marginal vein and the left distal ventricular vein. The left proximal ventricular vein was an inconstant tributary of the left circumflex vein and was seen in 17% of cases. The left distal ventricular vein was visible as one (13% of cases) or two veins (87% of cases). Angular vein was observed in 20% of cases. Numerous anastomosis were found among cardiac veins.  相似文献   

7.
The efficacy of low-molecular-weight heparin as a prophylactic agent was assessed in 150 consecutive patients over the age of 40 undergoing major abdominal surgery. Fifty of these patients received 1250 activated partial thromboplastin time (APTT) units of low-molecular-weight heparin every 12 hours: three developed isotopic deep vein thrombosis, which was confirmed by phlebography in two cases. The other 100 patients received a single injection of 1850 APTT units of low-molecular-weight heparin. Three of them developed isotopic deep vein thrombosis; phlebography failed to confirm the presence of thrombi in each case. None of the 150 patients studied died from fatal or contributory pulmonary emboli. Low-molecular-weight heparin was not associated with any increase in preoperative or postoperative bleeding. The effect of equal amounts of postoperative bleeding. The effect of equal amounts of low-molecular-weight heparin and unfractionated heparin on the coagulation mechanism during surgery was investigated in another 30 patients. The clotting assays and results of in-vivo platelet function tests indicated that both preparations produced similar effect. Intragroup comparisons, however, showed significant differences in the anti-factor Xa activity, lipoprotein lipase release, and plasma prekallikrein concentrations. A single injection of low-molecular-weight heparin daily is a convenient way of preventing deep vein thrombosis in high-risk patients undergoing major abdominal surgery.  相似文献   

8.
In a multicenter randomized trial, the efficacy and safety of two streptokinase (SK) dosage regimens have been evaluated in patients with proximal deep vein thrombosis of inferior limbs. Twenty-nine patients received SK by a continuous intravenous infusion (250,000 IU as initial dose, 100,000 IU/h as maintenance dose), and 26 patients were treated with intermittent SK administration (500,000 IU as initial dose, followed by 250,000 IU every 12 h). Thrombolytic therapy was continued for 4 days, then the patients received heparin for 5 days and oral anticoagulant for 3 months. The results of treatment as judged by phlebographic examinations were similar in the two groups. Complete, substantial or partial thrombolysis was achieved in 52% of patients in the continuous infusion group and in 58% of patients in the intermittent treatment group. During SK administration, major bleeding complications occurred in 6 patients treated by continuous infusion and in 2 of the second group. The results showed that the intermittent SK administration is as effective and safe as the method of continuous SK infusion in the treatment of deep vein thrombosis.  相似文献   

9.
Measurements of the heparin level were made under continuous anticoagulation in a total of 7 patients. For the purpose of monitoring heparin the coagulation time values were determined parallelly. Except a patient with a sepsis and a 7 days old newborn baby the desired prolongation for the partial thromboplastin time and the reaction time of thrombelastogram resulted from heparin titres lying within the range of 0.2-0.7 U/ml of plasma. Even after applying depot preparations there was a relatively good correspondance of heparin level curves and coagulation parameters. In childhood the partial thromboplastin time is primarily suitable for monitoring the heparin therapy. Heparin half-life times calculated during the transumbilical exchange transfusion in 7 children amounted to values ranging between 40-110 minutes. In addition to checking low dose heparinizing, measurements of the level are suitable for deriving dosage standards for neutralizing heparin effects by protamine sulfate.  相似文献   

10.
The authors describe, in the first report of this type of replantation surgery, a high success rate using delayed venous anastomosis in 16 consecutive distal phalangeal replantations under digital block. Among these replantations, seven fingers (43.8 percent) showed postoperative venous congestion and five fingers were reoperated on with delayed venous drainage under digital block. All the reoperated fingers were successfully drained by additional single or double venous drainage with a vein graft. As a result, 13 fingers survived (81.3 percent success rate). All operations were performed under a digital block.  相似文献   

11.
Air infused into the jugular vein of dogs at a constant rate for one hour produced transient hypotension, modest elevation of the systemic venous pressure and a considerable fall of the arterial oxygen tension. All of these measurements returned almost to normal on the termination of the infusion. A lethal rate of infusion, 0.69 ml of air per kg of body weight per minute, produced heart failure with a decided rise of systemic venous pressure and fall of blood pressure. The pre-failure oxygen pressure did not fall to a lethal level. Six and a half minutes was the longest time that the characteristic murmur could be heard after the cessation of infusion of non-fatal doses of air.  相似文献   

12.

Background

Hemodialysis arteriovenous synthetic grafts (AVG) provide high volumetric blood flow rates shortly after surgical placement. However, stenosis often develops at the vein-graft anastomosis contributing to thrombosis and early graft failure. Two novel fusion proteins, ANV-6L15 and TAP-ANV, inhibit the tissue factor/factor VIIa coagulation complex and the factor Xa/factor Va complex, respectively. Each inhibitor domain is fused to an annexin V domain that targets the inhibitor activity to sites of vascular injury to locally inhibit thrombosis. This study’s objective was to determine if these antithrombotic proteins are safe and effective in inhibiting AVG stenosis.

Methods

A bolus of either TAP-ANV or ANV-6L15 fusion protein was administered intravenously immediately prior to surgical placement of a synthetic graft between the external jugular vein and common carotid artery in a porcine model. At surgery, the vein and artery were irrigated with the anti-thrombotic fusion protein. Control animals received intravenous heparin. At 4 weeks, MRI was performed to evaluate graft patency, the pigs were then euthanized and grafts and attached vessels were explanted for histomorphometric assessment of neointimal hyperplasia at the vein-graft anastomosis. Blood was collected at surgery, immediately after surgery and at euthanasia for serum metabolic panels and coagulation chemistries.

Results

No acute thrombosis occurred in the control group or in either experimental group. No abnormal serum chemistries, activated clotting times or PT, PTT values were observed after treatment in experimental or control animals. However, at the vein-graft anastomosis, there was no difference between the control and experimental groups in cross-sectional lumen areas, as measured on MRI, and no difference in hyperplasia areas as determined by histomorphometry. These results suggest that local irrigation of TAP-ANV or ANV-6L15 intra-operatively was as effective in inhibiting acute graft thrombosis as intravenous administration of heparin, but failed to inhibit hyperplasia development and stenosis in AVG.  相似文献   

13.
A questionnaire was sent to 508 consultants in Scotland likely to encounter deep vein thrombosis and pulmonary embolism to assess their current standard practice in diagnosis and treatment of these disorders. Replies were received from 358 (70.5%). In deep vein thrombosis 47% and in pulmonary embolism 33% of consultants usually depended on clinical observation alone for diagnosis. In deep vein thrombosis 37% used venography to supplement clinical diagnosis and in pulmonary embolism 13% used angiography and 53% used isotopic scanning. Almost all consultants treated deep vein thrombosis (95%) and pulmonary embolism (99%) with anticoagulants. Most consultants (81%) gave heparin by intravenous infusion. Although many consultants gave intravenous heparin for more than three days (49.5% in deep vein thrombosis and 61% in pulmonary embolism), 25% of these consultants did not use any laboratory monitoring of heparin''s effect. Large numbers of consultants gave warfarin for more than three months (20% in deep vein thrombosis and 47% in pulmonary embolism). There was a significant tendency to give heparin (p less than 0.01) and warfarin (p less than 0.001) for longer periods in pulmonary embolism than in deep vein thrombosis. This survey shows a widely varying practice and underlines the need for further controlled studies to provide clear guidance in the management of deep vein thrombosis and pulmonary embolism.  相似文献   

14.
We have developed and validated catheterization protocols in mice that allow for simultaneous infusion and sampling. A sampling catheter was inserted in the lateral vein of the tail, while the animals were infused either intravenously or intragastrically through a second catheter placed in the contralateral lateral vein or via an intragastric catheter, respectively. The applicability of these methods of infusion and blood sampling were validated by conducting urea kinetics utilizing stable isotopes. These non-surgical procedures are non-invasive, inexpensive, fast to perform and animals do not require a recovery period before their use.  相似文献   

15.
M C Shu  G P Noon  N H Hwang 《Biorheology》1987,24(6):711-722
A phase-by-phase analysis of local flow patterns at the venous anastomosis of an arteriovenous hemodialysis angioaccess loop graft (AVLG) was made. The study was carried out in an elastic, transparent Silastic in vitro flow model, which duplicates the detail geometry of the AVLG obtained from an animal model (30+ kg dogs with 12 weeks bilateral femoral AVLG implantation). The flow model was installed in a mock pulsatile flow loop system designed to simulate physiological conditions. Flow visualization was made in laser-illuminated flow fields using a high-speed cine camera. Analysis of the high-speed cine indicates there is a distinct separation region downstream of the anastomotic toe in the median plane and a stagnation region that oscillates along the opposite wall. During inward motion of the vessel wall, accumulation of particles in the separation region and the nearby stagnation region is observed. A large swirl appears in the distal vein during end-systolic period. A double-helical flow pattern occurs further down in the distal vein. Retrograde flow in the distal vein occurs in an "oscillating" manner following each cardiac cycle.  相似文献   

16.
Significance of venous anastomosis in fingertip replantation   总被引:5,自引:0,他引:5  
Adequate venous outflow is the most important factor for successful fingertip replantation. The authors have attempted venous anastomosis in all cases of fingertip replantation to overcome postoperative congestion. In this article, the significance of venous repair for fingertip replantation is described from the authors' results of 64 complete fingertip amputations in 55 consecutive patients, which were replanted from January of 1996 to June of 2001. The overall survival rate was 86 percent. Of the 44 replantations in zone I, 37 survived, and the success rate was 84 percent. Of the 20 replantations in zone II, 18 survived, and the success rate was 90 percent. Venous anastomosis was attempted in all cases, but it was possible in 39 zone I and in all zone II replantations. For arterial repair, vein grafts were necessary in 17 of the 44 zone I and in one of the 20 zone II replantations; for venous repair, they were necessary in six zone I replantations and one zone II replantation. Postoperative vascular complications occurred in 15 replantations. There were five cases of arterial thrombosis and 10 cases of venous congestion. Venous congestion occurred in nine zone I and one zone II replantations. In five of these 10 replantations, venous anastomosis was not possible. In another five replantations, venous outflow was established at the time of surgery, but occlusion occurred subsequently. Except for the five failures resulting from arterial thrombosis, successful venous repair was possible in 49 of 59 replantations (83 percent). Despite the demand for skillful microsurgical technique and longer operation time, the authors' results using venous anastomosis in successful fingertip replantations are encouraging. By performing venous anastomosis, external bleeding can be avoided and a higher survival rate can be achieved. Venous anastomosis for fingertip replantation is a reliable and worthwhile procedure.  相似文献   

17.
To assess whether adding low-dose heparin to the infusate of patients receiving parenteral nutrition reduced the incidence of septic complications related to the central venous catheter, 80 consecutive patients requiring intravenous feeding were studied. Half of these patients received heparin 1 unit/ml of infusate, while in the remaining 40 (controls) an equal volume of physiological saline was added to the infusate. Strict criteria for the management of the indwelling CVC were observed. The catheter tips were cultured after removal: only one was infected in the heparin group compared with nine in the control group. This significant reduction may have been due to the heparin preventing a fibrin sleeve from forming around the catheter tip. It is recommended that, as well as observing the usual aseptic precautions in managing the cannula, 500 units of heparin are added to each 500 ml of fluid infused to reduce the incidence of catheter-associated sepsis.  相似文献   

18.
The creation of successful vascular anastomoses is of primary importance in many surgical fields. Numerous attempts to automate this process have been made. These techniques have slowly gained acceptance, but their use is still limited. This report details feasibility testing of a new prototype stapler that automates the rollover sleeve technique for venous vascular anastomoses. Male and female mongrel dogs (n=7) (25-32 kg) were used. A segment of the right (n=5) or left (n=2) iliac vein was harvested for interposition grafts after the contra lateral side was transected. In each dog, two end-to-end venous anastomoses at the interposition grafts were performed. The standard anastomosis employed continuous mattress sutures. The experimental anastomosis was performed with a new prototype surgical stapler. The stapled anastomosis was proximal and the sutured was distal. In all experiments, it was possible to perform the experimental anastomosis with the stapler. Complications included two small leaks, one due to misfiring of a single pin in one experimental site. These leaks required suture reinforcement. One dog died of hemorrhage due to a slipped suture at the vein harvest site. One vein had thrombus seen at the sutured site although no technical abnormalities at either of the anastomoses could be found. After two weeks, grafts were inspected grossly and histologically. Healing appeared normal. There was a trend for less inflammatory cells infiltrating stapled sites; however, this was not statistically significant. The experiments demonstrate that this device can automate the rollover sleeve technique for venous anastomoses.  相似文献   

19.
Arteriovenous (AV) grafts and fistulas used for hemodialysis frequently develop intimal hyperplasia (IH) at the venous anastomosis of the graft, leading to flow-limiting stenosis, and ultimately to graft failure due to thrombosis. Although the high AV access blood flow has been implicated in the pathogenesis of graft stenosis, the potential role of needle turbulence during hemodialysis is relatively unexplored. High turbulent stresses from the needle jet that reach the venous anastomosis may contribute to endothelial denudation and vessel wall injury. This may trigger the molecular and cellular cascade involving platelet activation and IH, leading to eventual graft failure. In an in-vitro graft/needle model dye injection flow visualization was used for qualitative study of flow patterns, whereas laser Doppler velocimetry was used to compare the levels of turbulence at the venous anastomosis in the presence and absence of a venous needle jet. Considerably higher turbulence was observed downstream of the venous needle, in comparison to graft flow alone without the needle. While turbulent RMS remained around 0.1 m/s for the graft flow alone, turbulent RMS fluctuations downstream of the needle soared to 0.4-0.7 m/s at 2 cm from the tip of the needle and maintained values higher than 0.1 m/s up to 7-8 cm downstream. Turbulent intensities were 5-6 times greater in the presence of the needle, in comparison with graft flow alone. Since hemodialysis patients are exposed to needle turbulence for four hours three times a week, the role of post-venous needle turbulence may be important in the pathogenesis of AV graft complications. A better understanding of the role of needle turbulence in the mechanisms of AV graft failure may lead to improved design of AV grafts and venous needles associated with reduced turbulence, and to pharmacological interventions that attenuate IH and graft failure resulting from turbulence.  相似文献   

20.
How TV  Fisher RK  Hoedt MT  Brennan J  Harris PL 《Biorheology》2002,39(3-4):461-465
Clinical evidence suggests that the development of myointimal hyperplasia in prosthetic femorodistal bypass grafts may be reduced by the interposition of a cuff of autologous vein between the graft and the recipient artery. Previous experimental work has shown that some of the benefits may be attributed to the geometry of the cuffed anastomosis. Since the distal anastomosis in vivo is often non-planar we have carried out a preliminary study in a model where the graft is at an angle of 45 degrees to the anterior-posterior plane of the anastomosis. This out-of-plane angulation produces highly asymmetric flow patterns in the anastomosis with significant flow separation on the ipsilateral side of the cuff. In the proximal and distal outflow, however, the velocity vectors show significant helical motion with temporal instability in the distal outflow.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号