首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fluorescence microscopy in combination with multiple, simultaneous labeling of biomolecules has been a key breakthrough in cell biology. However, the spatiotemporal resolution of this approach is limited by bleaching of the fluorescence label and illegitimate cross-reference of the label. CdSe-based semiconductor nanocrystals with their excellent bleaching stability would be an alternative to overcome this limitation. We therefore explored direct immunofluorescence based on nanocrystal-conjugated antibodies using plant microtubules as model. We compared two strategies of bioconjugation, covalent coupling of antitubulin antibodies to BSA-coated nanocrystals and covalent coupling to nanocrystals that were surrounded by functionalized silica shells. Both nanoparticle-antibody conjugates were used to follow the dynamic reorganization of microtubules through the cell cycle of a tobacco cell culture in double and triple staining with FITC as conventional fluorochrome and Hoechst 33258 as marker for mitotic duplication of DNA. BSA-coated nanocrystals visualized fluorescent dots that decorated the various arrays of microtubules. The specificity of the antibody was maintained after conjugation with the nanocrystals, and the antibodies correctly represented the dynamics of cell-cycle-dependent microtubular reorganization. However, this approach did not yield a contiguous signal. In contrast, silica-shelled nanocrystals visualized contiguous microtubules in the same pattern as found for the conventional fluorochrome FITC and thus can be used as labels for direct immunofluorescence in plant cells.  相似文献   

2.
Monoclonal antibodies specific for phycoerythrin (PE) were covalently labeled with the fluorescent dye cyanine 5 (Cy5). Excitation at 488 nm of immune complexes obtained by mixing Cy5-anti-PE with PE resulted in a 4-fold reduction of PE fluorescence measured at 565 nm and an increase of fluorescence measured at 655 nm. The observed energy transfer between PE and Cy5-anti-PE was used to develop three color immunofluorescence staining procedures for flow cytometers equipped with an Argon laser tuned at 488 nm. Mouse IgG1 monoclonal antibodies specific for cell surface antigens were cross-linked with either unlabeled or Cy5 labeled mouse IgG1 anti-PE using F(ab')2 fragments of monoclonal rat anti-mouse IgG1. PE was added to these immune complexes in sufficient amounts to saturate all PE binding sites. Cells were incubated with PE-labeled and PE/Cy5-labeled tetrameric antibody complexes together with FITC labeled antibodies and analyzed by flow cytometry. The emission from FITC, PE and PE/Cy5 could be readily separated and bright three color immunofluorescence staining of mononuclear cells from human peripheral blood and bone marrow was observed. The results of these experiments demonstrate that useful probes for single laser three color staining of cell surface antigens can be readily obtained by mixing of selected reagents. Compared to standard procedures for the covalent labeling of PE (tandem) molecules to antibodies, the non-covalent procedures described in this report provide significant advantages in terms of the amount of reagents, time and equipment required to obtain suitable reagents for three color immunofluorescence staining.  相似文献   

3.
A cytochemical technique for the ultrastructural localization of unique nuclear antigens is reported. Using a post-embedding indirect immunogold labeling procedure, nuclear antigens in electron-dense regions of the nucleus are localized with a minimum of nonspecific staining. Using this technique and indirect immunofluorescence, a panel of antinuclear monoclonal antibodies is shown to recognize preferentially cell cycle-dependent nuclear substructures. The antigenic domains recognized include specific regions in condensed chromatin, interchromatin granules, euchromatin, and chromosomes. The specificity of antigen recognition is demonstrated with qualitative and quantitative immunogold electron microscopy and immunoblot analysis. These results reveal the existence of previously undefined supramolecular organization within the nucleus and demonstrate the utility of the immunogold procedure when monoclonal antibodies are used.  相似文献   

4.
Nine monoclonal antibodies to rabbit T cells and B subpopulations have been generated from three separate fusions of spleen cells from mice immunized with fractionated populations of rabbit lymphocytes. These monoclonal antibodies, as well as a previously described rabbit T cell monoclonal antibody, 9AE10, have been analyzed by immunofluorescence staining on frozen tissue sections of rabbit thymus, spleen, and appendix. This screening method permits rapid identification of the lymphocyte subdomains in each tissue which is not possible by other screening methods. Each monoclonal antibody selected has a unique tissue staining pattern. Flow cytometric analysis of these monoclonal antibodies, using indirect immunofluorescence techniques on thymocytes, splenocytes, and PBL, revealed varying percentages of positive cells and individual mean fluorescence intensities indicating different epitope densities for each antigen. These monoclonal antibodies are now being used to characterize normal lymphocyte function and the role of specific lymphocyte subpopulations in experimental disease models in the rabbit.  相似文献   

5.
Total nuclear protein from the embryonic D. melanogaster cell line Kc and crude hydroxyapatite fractions thereof were used for immunization of mice. From the spleen cells of these mice we established 755 permanent lymphoid cell lines using the hybridoma technique originally developed by Köhler and Milstein (1975). Radioimmunoassay showed 455 of these cell lines secreted antibodies which bound to component(s) contained in the antigen mixtures used for immunization. Screening of 311 cell lines using indirect immunofluorescence revealed 58 lines whose antibodies showed a highly selective staining pattern on polytene chromosomes from the salivary glands of D. melanogaster third instar larvae. Eight of these cell lines were cloned and further characterized. We were able to order the staining patterns into three distinct classes based on the staining behaviour of the monoclonal antibodies: staining of active regions, staining of phase dark bands or staining of most interbands. The molecular weight of those antigens against which the monoclonal antibodies were directed was determined in SDS polyacrylamide gels.  相似文献   

6.
A preparative technique for the two-parameter flow cytometric study of nuclear antigen expression is reported. This method employs a brief sequential treatment of cells at 4 degrees C first with 0.5% paraformaldehyde and second with 0.1% Triton X-100 in phosphate-buffered saline followed by cellular staining with indirect immunofluorescence and propidium iodide. Using this technique, cellular morphology is preserved, cell clumping is minimized, and high-quality indirect immunofluorescence and DNA staining are obtained with a minimum of nonspecific labeling. Utilizing nuclear antigen-specific monoclonal antibodies in conjunction with this technique, the cell-cycle phase-dependent expression of such antigens is examined. From these data, the utility of two-parameter flow cytometry in the identification and quantification of cell-cycle-dependent modulation of nuclear antigens is discussed.  相似文献   

7.
Boggs BA  Allis CD  Chinault AC 《Chromosoma》2000,108(8):485-490
One of the prominent cell cycle-related modifications of histone proteins whose function remains unresolved is the phosphorylation of linker histone H1. In this work we have used indirect immunofluorescence on human cells with antibodies that are specific for phosphorylated histone H1 to examine the cellular distribution and chromosome association patterns of this protein. With confocal microscopy on whole cells, strong immunofluorescence was seen in association with mitotic chromosomes as well as a prominent punctate pattern of labeling throughout the mitotic cell, whereas interphase cells showed very little, if any, specific fluorescence. Multiple patterns of fluorescence distribution were detected with metaphase chromosomes, ranging from apparent tight colocalization with the DNA to expanded ”puffy” mitotic figures to an amorphous network of staining. It was also shown that the ability to label chromosomes could vary drastically with different fixation procedures, adding further complications to interpretation of the potentially complex role of phosphorylated histone H1 in chromatin condensation or decondensation. Received: 8 September 1999; in revised form: 14 September 1999 / Accepted: 17 September 1999  相似文献   

8.
本文采用细胞分级抽提结合整装细胞电镜制样技术,分别在两种昆虫细胞:斜纹夜蛾(SL)细胞;甜菜夜蛾(SE)细胞中显示了一个精细的中等纤维网络结构,纤维自胞核发出,排列错综复杂,其单丝清晰可见,直径约为8~10nm;间接免疫荧光染色结果表明角蛋白抗体在两种细胞中均能显示出清晰的荧光纤维网络,而且荧光纤维的分布有所不同;用角蛋白抗体对这两种细胞全蛋白进行免疫印迹实验,均可显示49KD,68KD的两个主要多肽条带,说明这两种昆虫细胞中等纤维的主要成分为角蛋白.  相似文献   

9.
胡金朝 《西北植物学报》2012,32(8):1573-1578
分别用考马斯亮蓝染色和间接免疫荧光标记,并运用荧光倒置显微镜和激光共聚焦显微镜,对慈姑根尖固定后酶解获得的去壁细胞和细胞团块以及根尖细胞分裂周期中微管骨架列阵进行详细观察,以探索高等植物微管周期的普遍性。结果表明:慈姑根尖固定后酶解可获得大量结构完整的去壁细胞与细胞团块;考马斯亮蓝染色观察可见,慈姑根尖细胞中丰富的蛋白物质以及处于不同分裂期的细胞核染色体;免疫荧光观察可见,慈姑根尖细胞周期中微管骨架保存较好,主要有周质微管、早前期带微管、纺缍体微管和成膜体微管4种循序变化的排列方式,构成了高等水生植物分裂细胞中典型的微管周期。实验结果证明,高等水生植物与陆生植物微管周期具有相似性,为植物微管周期概念提供了新的实例。  相似文献   

10.
Using indirect immunofluorescence, nuclear non-histone protein BA was localized in a normal rat liver cell line. Protein BA antibodies immunostained nuclear structures producing a speckled immunofluorescent staining pattern. Nuclear structures stained with protein BA antibodies were sensitive to DNase I digestion, but not to RNase. The speckled pattern of nuclear fluorescence observed with protein BA antibodies was similar to that reported earlier for Sm antibodies, which react with U-snRNPs. Using double-label indirect immunofluorescence, the Sm antigen was shown to be concentrated in the same regions of the nucleus which contain protein BA. Immunoblot analysis of total nuclear proteins with the two antibodies demonstrated that protein BA and the major Sm antigen have similar molecular weights, but are antigenically distinct. In addition, they differ in their extractabilities from the cell nucleus.  相似文献   

11.

Introduction

Autoantibodies to the ribosomal P proteins represent a highly specific marker for the diagnosis of systemic lupus erythematosus, where they have been associated with certain clinical manifestations. Historically, autoantibodies against ribosomal P proteins have been detected by indirect immunofluorescence, immunodiffusion, immunoblot, and other immunoassays. More recently, enzyme-linked immunosorbent assays and line and addressable laser bead immunoassays have become more widely used. The primary goal of this study was to determine the sensitivity of indirect immunofluorescence using conventional HEp-2 substrates in the detection of sera with ribosomal P antibodies as detected by other immunoassays.

Methods

Anti-ribosomal P-positive sera (n = 345) as detected by an addressable laser bead immunoassay were collected between 2003 and 2007 and analysed by indirect immunofluorescence. Furthermore, 51 anti-ribosomal P-positive samples from an unselected systemic lupus erythematosus cohort (n = 100) and the Centers for Disease Control and Prevention (CDC) anti-nuclear antibody (ANA) reference sera were tested for anti-ribosomal P reactivity.

Results

In the cohort of 345 anti-ribosomal P-positive samples identified by addressable laser bead immunoassay, a low sensitivity (<30%) of indirect immunofluorescence on HEp-2 cell substrates was observed. Although the degree of sensitivity varied among different manufacturers, all immunofluorescence substrates exhibited limited sensitivity and false-negative results were not restricted to samples with low anti-ribosomal P titers. Even the anti-ribosomal P reactivity of CDC ANA reference serum number 12 was not clearly predictable by indirect immunofluorescence. Comparison of five different methods for the detection of anti-ribosomal P found moderate qualitative agreements.

Conclusions

Based on our data, we conclude that indirect immunofluorescence on HEp-2 cells is not a reliable screening test for the prediction of ribosomal P antibodies. As this method is widely used as a first-line screening test for anti-nuclear and other autoantibodies, special considerations for the detection of ribosomal P antibodies are needed. As with many other autoantibodies, further effort is required for the standardisation of ribosomal P immunoassays.  相似文献   

12.
An indirect immunofluorescence colony staining method was developed for the detection of important seed-borne bacterial pathogens of tomato. The method involves the use of specific antiserum for initial binding of target bacteria and visualization of positive colonies with a commercially available secondary antiserum conjugated with FITC and observed under a fluorescence microscope. The indirect method is especially suitable for laboratories, seed companies, and quarantine stations which have no facilities for conjugation of primary antiserum. It is more economical and overcomes the problems generally encountered with variable conjugate quality in new batches of conjugates prepared from the same stock of primary antiserum. The assay is easy to perform and results can be easily assessed by visual scoring or image analyser. Results are available in 4-5 days as compared to 30-45 days in traditional methods. The resulting bacterial culture can be tested by PCR or host infectivity and a culture can be stored for future reference. Used in combination with highly specific antibodies (commercially available monoclonal and recombinant antibodies) it can be used as a very sensitive detection tool and has application potential in localization studies as well. Choosing the right secondary conjugate is however necessary to get best results in the assay.  相似文献   

13.
We have studied the intensity of staining of helper/inducer T-cells in lymph node and tonsillar tissue using two commercially available monoclonal antibodies (OKT4 and Leu3a) with the indirect immunoperoxidase method. Paracortical and mantle zone helper/inducer T-cells were easily visualized by both monoclonal antibodies, but T-cells in the follicular center, though stained by Leu3a, were hardly demonstrable by OKT4. Excellent staining was obtained in the indirect immunoperoxidase procedure by incubating the sections with a 1:1 mixture of the two monoclonal antibodies which gave bright staining of individual cells throughout the lymphoid tissue. Dilution of the primary antibodies by 1:200 did not affect the results. It is concluded that the simultaneous application of OKT4 and Leu3a as primary antibodies in the indirect immunoperoxidase procedure is the method of choice for the in situ demonstration of helper/inducer T-cells.  相似文献   

14.
We have studied the intensity of staining of helper/inducer T-cells in lymph node and tonsillar tissue using two commercially available monoclonal antibodies (OKT4 and Leu3a) with the indirect immunoperoxidase method. Paracortical and mantle zone helper/inducer T-cells were easily visualized by both monoclonal antibodies, but T-cells in the follicular center, though stained by Leu3a, were hardly demonstrable by OKT4. Excellent staining was obtained in the indirect immunoperoxidase procedure by incubating the sections with a 1:1 mixture of the two monoclonal antibodies which gave bright staining of individual cells throughout the lymphoid tissue. Dilution of the primary antibodies by 1:200 did not affect the results. It is concluded that the simultaneous application of OKT4 and Leu3a as primary antibodies in the indirect immunoperoxidase procedure is the method of choice for the in situ demonstration of helper/inducer T-cells.  相似文献   

15.
本文使用细胞的选择性抽提、DGD包埋去包埋电镜制样、免疫荧光和免疫印迹技术研究了小鼠胚胎干细胞(ES-Ml_(13))的核骨架-核纤层-中间纤维(NM-L-IF)结构体系。在电镜下可以看到,ES细胞存在精细发达的核骨架结构,核骨架纤维同核纤层结构相连接,细胞质中有许多直径为10nm的中间纤维单丝。在免疫荧光分析中,使用角蛋白单克隆抗体有阳性反应,细胞质区域可以看到较强的荧光,没有极性分布现象,也没有观察到纤维状的荧光染色。ES细胞对波形蛋白和结蛋白抗体呈阴性反应,同对照组一样,只能看到非特异性的很微弱的荧光染色。在免疫印迹分析中,使用角蛋白单克隆抗体AF6检测到三条角蛋白多肽,分子量分别为65KD,62KD和52KD。  相似文献   

16.
The relative ease with which a flow cytometer can perform simultaneous two color immunofluorescence to examine subpopulations of lymphoid cells has been well documented. Thus, flow cytometers equipped with only a single argon laser can be used to delineate various cell types by exciting both fluorescein- and phycoerythrin-conjugated antibodies to cell surface antigens. One problem that remains, however, is the artifactual staining of dead cells and clumps, which cannot be distinguished from viable cells on the basis of cell surface staining characteristics. We describe a method for simultaneous two color analysis or sorting of viable leukocytes which requires only a single laser. The method utilizes propidium iodide, which stains dead cells and thereby excludes such cells from the analysis. Using this method, as many as four viable cell types have been simultaneously analyzed in a single sample.  相似文献   

17.
Combining fluorescence in situ hybridization (FISH) and indirect immunofluorescence staining of protein markers provides a highly specific method for identifying chromosomes in phenotypically defined cells and tissues. We developed a technique enabling dual chromosome painting and immunofluorescence staining of archival formalin-fixed, paraffin-embedded material, and used this to phenotype chimeric cells in female-to-male human liver transplants.  相似文献   

18.
H M Shapiro 《Cytometry》1981,2(3):143-150
The addition of RNA content estimation to flow cytometric measurement of DNA content provides valuable information concerning cells' transitions between quiescent and proliferative states. Equilibrium staining methods employing acridine orange have been used for DNA/RNA content measurement but are difficult to apply to intact cells and impractical for use in conjunction with fluorescent antibodies or ligands for demonstration of cell surface structures. I have used a combination of Hoechst 33342 (HO342) and pyronin Y (PY) to stain intact cells for DNA/RNA content estimation with a dual source flow cytometer using UV and blue-green or green excitation, measuring HO342 fluorescence at 430--470 nm and PY fluorescence at 590--650 nm. Results obtained with cultured cells and stimulated lymphocytes are in good agreement with those obtained using acridine orange for DNA/RNA staining; about half of the PY fluorescence can be removed from ethanol-fixed cells stained with HO342 and PY by RNAse digestion. The HO342/PY method can be combined with fluorescein immunofluorescence for detection of cell surface markers. HO342 can be combined with other tricyclic heteroaromatic dyes for DNA/RNA estimation; the combination of HO342 and oxazine 1 can be excited in a dual source instrument using a mercury arc lamp and a helium-neon laser. The staining procedure is simple; cells in medium are incubated with 5 microM HO342 at 37 degrees C for 45 min, 5 microM PY (or oxazine 1) is then added and cells are analyzed without washing after an additional 45 min incubation. Suitability of these dye combinations for vital cell staining and sorting remains to be determined.  相似文献   

19.
Rabbit antibodies to the nuclear Tris extract of HeLa cells which have been shown by the indirect immunofluorescence technique to localize in nucleoli of a variety of human malignant tumors but not in a number of nontumor tissues also produced bright fluorescence in nucleoli of tumor cells in several hematological malignancies. The tumors studied included Hodgkins malignant lymphoma, non-Hodgkins malignant lymphoma, acute myeloid and acute myelomonocytic leukemia, chronic lymphatic and chronic myeloid leukemia. In contrast, none of the corresponding normal cell lines in the bone marrow exhibited bright nucleolar fluorescence. In addition, neither the cells of patients with acute infectious mononucleosis nor lymphoid hyperplasia exhibited bright nucleolar fluorescence. These studies suggest that antibodies to HeLa cell nucleolar antigens may be useful in immunodiagnosis of human malignancies.  相似文献   

20.
Antibodies prepared against actomyosins can be shown to behave similarly, if not identically to more recently prepared antibodies against highly purified myosins. Details of the purification of the antigens, and of the production of antibodies to chick myosins from smooth gizzard muscle and from striated pectoral muscle are given. The antibody specificity appears to be directed against the heavy chains of the myosin molecules, since these antibodies specifically inhibit the myosin ATPase reaction, and since in situ staining of myosin polypeptide chains on an SDS gel using the antibodies in indirect fluorescence shows staining only in the heavy band region. Use of the antibodies in immunofluorescence microscopy suggest that the antibodies are tissue, but not species, specific. Example of their use in staining tissue sections are shown.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号