首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An estimation of cardiac output can be obtained from arterial pressure waveforms using the Modelflow method. However, whether the assumptions associated with Modelflow calculations are accurate during whole body heating is unknown. This project tested the hypothesis that cardiac output obtained via Modelflow accurately tracks thermodilution-derived cardiac outputs during whole body heat stress. Acute changes of cardiac output were accomplished via lower-body negative pressure (LBNP) during normothermic and heat-stressed conditions. In nine healthy normotensive subjects, arterial pressure was measured via brachial artery cannulation and the volume-clamp method of the Finometer. Cardiac output was estimated from both pressure waveforms using the Modeflow method. In normothermic conditions, cardiac outputs estimated via Modelflow (arterial cannulation: 6.1 ± 1.0 l/min; Finometer 6.3 ± 1.3 l/min) were similar with cardiac outputs measured by thermodilution (6.4 ± 0.8 l/min). The subsequent reduction in cardiac output during LBNP was also similar among these methods. Whole body heat stress elevated internal temperature from 36.6 ± 0.3 to 37.8 ± 0.4°C and increased cardiac output from 6.4 ± 0.8 to 10.9 ± 2.0 l/min when evaluated with thermodilution (P < 0.001). However, the increase in cardiac output estimated from the Modelflow method for both arterial cannulation (2.3 ± 1.1 l/min) and Finometer (1.5 ± 1.2 l/min) was attenuated compared with thermodilution (4.5 ± 1.4 l/min, both P < 0.01). Finally, the reduction in cardiac output during LBNP while heat stressed was significantly attenuated for both Modelflow methods (cannulation: -1.8 ± 1.2 l/min, Finometer: -1.5 ± 0.9 l/min) compared with thermodilution (-3.8 ± 1.19 l/min). These results demonstrate that the Modelflow method, regardless of Finometer or direct arterial waveforms, underestimates cardiac output during heat stress and during subsequent reductions in cardiac output via LBNP.  相似文献   

2.
The objective of our study was to compare Doppler echocardiography imaging with pulmonary artery thermodilution measurement during mechanical ventilation. Total 78 piglets (6 weeks old, average weight 24 kg, under general anesthesia) were divided into 4 groups under different cardiac loading conditions (at rest, with increased left ventricular afterload, with increased right ventricular preload, and with increased afterload of both heart ventricles). At 60 and 120 min the animals were examined by echocardiography and simultaneously pulmonary artery thermodilution was used to measure cardiac output. Tei-indexes data were compared with invasively monitored hemodynamic data and cardiac output values together with calculated vascular resistance indices. A total of 224 parallel measurements were obtained. Correlation was found between values of right Tei-index of myocardial performance and changes in right ventricular preload (p<0.05) and afterload (p<0.01). Significant correlation was also found between left index values and changes of left ventricular preload (p<0.001), afterload (p<0.001), stroke volume (p<0.01), and cardiac output (p<0.01). In conclusion, echocardiographic examination and determination of the global performance selectively for the right and left ventricle can be recommended as a suitable non-invasive supplement to the whole set of methods used for monitoring of circulation and cardiac performance.  相似文献   

3.
Foreign and soluble gas rebreathing methods are attractive for determining cardiac output (Q(c)) because they incur less risk than traditional invasive methods such as direct Fick and thermodilution. We compared simultaneously obtained Q(c) measurements during rest and exercise to assess the accuracy and precision of several rebreathing methods. Q(c) measurements were obtained during rest (supine and standing) and stationary cycling (submaximal and maximal) in 13 men and 1 woman (age: 24 +/- 7 yr; height: 178 +/- 5 cm; weight: 78 +/- 13 kg; Vo(2max): 45.1 +/- 9.4 ml.kg(-1).min(-1); mean +/- SD) using one-N(2)O, four-C(2)H(2), one-CO(2) (single-step) rebreathing technique, and two criterion methods (direct Fick and thermodilution). CO(2) rebreathing overestimated Q(c) compared with the criterion methods (supine: 8.1 +/- 2.0 vs. 6.4 +/- 1.6 and 7.2 +/- 1.2 l/min, respectively; maximal exercise: 27.0 +/- 6.0 vs. 24.0 +/- 3.9 and 23.3 +/- 3.8 l/min). C(2)H(2) and N(2)O rebreathing techniques tended to underestimate Q(c) (range: 6.6-7.3 l/min for supine rest; range: 16.0-19.1 l/min for maximal exercise). Bartlett's test indicated variance heterogeneity among the methods (P < 0.05), where CO(2) rebreathing consistently demonstrated larger variance. At rest, most means from the noninvasive techniques were +/-10% of direct Fick and thermodilution. During exercise, all methods fell outside the +/-10% range, except for CO(2) rebreathing. Thus the CO(2) rebreathing method was accurate over a wider range (rest through maximal exercise), but was less precise. We conclude that foreign gas rebreathing can provide reasonable Q(c) estimates with fewer repeat trials during resting conditions. During exercise, these methods remain precise but tend to underestimate Q(c). Single-step CO(2) rebreathing may be successfully employed over a wider range but with more measurements needed to overcome the larger variability.  相似文献   

4.
We evaluated whether a reduction in cardiac output during dynamic exercise results in vasoconstriction of active skeletal muscle vasculature. Nine subjects performed four 8-min bouts of cycling exercise at 71 +/- 12 to 145 +/- 13 W (40-84% maximal oxygen uptake). Exercise was repeated after cardioselective (beta 1) adrenergic blockade (0.2 mg/kg metoprolol iv). Leg blood flow and cardiac output were determined with bolus injections of indocyanine green. Femoral arterial and venous pressures were monitored for measurement of heart rate, mean arterial pressure, and calculation of systemic and leg vascular conductance. Leg norepinephrine spillover was used as an index of regional sympathetic activity. During control, the highest heart rate and cardiac output were 171 +/- 3 beats/min and 18.9 +/- 0.9 l/min, respectively. beta 1-Blockade reduced these values to 147 +/- 6 beats/min and 15.3 +/- 0.9 l/min, respectively (P < 0.001). Mean arterial pressure was lower than control during light exercise with beta 1-blockade but did not differ from control with greater exercise intensities. At the highest work rate in the control condition, leg blood flow and vascular conductance were 5.4 +/- 0.3 l/min and 5.2 +/- 0.3 cl.min-1.mmHg-1, respectively, and were reduced during beta 1-blockade to 4.8 +/- 0.4 l/min (P < 0.01) and 4.6 +/- 0.4 cl.min-1.mmHg-1 (P < 0.05). During the same exercise condition leg norepinephrine spillover increased from a control value of 2.64 +/- 1.16 to 5.62 +/- 2.13 nM/min with beta 1-blockade (P < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
We examined the central hemodynamic (n = 5) and leg blood flow (n = 9) responses to one- and two-leg bicycle exercise in nine ambulatory patients with chronic heart failure due to left ventricular systolic dysfunction (ejection fraction 17 +/- 9%). During peak one- vs. two-leg exercise, leg blood flow (thermodilution) tended to be higher (1.99 +/- 0.91 vs. 1.67 +/- 0.91 l/min, P = 0.07), whereas femoral arteriovenous oxygen difference was lower (13.6 +/- 3.1 vs. 15.0 +/- 2.9 ml/dl, P less than 0.01). Comparison of data from exercise stages matched for single-leg work rate during one- vs. two-leg exercise demonstrated that cardiac output was similar while both oxygen consumption and central arteriovenous oxygen differences were lower, indicating relative improvement in the cardiac output response at a given single-leg work rate during one-leg exercise. This was accompanied by higher leg blood flow (1.56 +/- 0.76 vs. 1.83 +/- 0.72 l/min, P = 0.02) and a tendency for leg vascular resistance to be lower (92 +/- 54 vs. 80 +/- 48 Torr.l-1.min, P = 0.08) without any change in blood lactate. These data indicate that, in patients with chronic heart failure, leg vasomotor tone is dynamically regulated, independent of skeletal muscle metabolism, and is not determined solely by intrinsic abnormalities in skeletal muscle vasodilator capacity. Our results suggest that relative improvements in central cardiac function may lead to a reflex release of skeletal muscle vasoconstrictor tone in this disorder.  相似文献   

6.
BackgroundThermodilution technique using a pulmonary artery catheter is widely used for the assessment of cardiac output (CO) in patients undergoing liver transplantation. However, the unclearness of the risk-benefit ratio of this method has led to an interest in less invasive modalities. Thus, we evaluated whether noninvasive bioreactance CO monitoring is interchangeable with thermodilution technique.MethodsNineteen recipients undergoing adult-to-adult living donor liver transplantation were enrolled in this prospective observational study. COs were recorded automatically by the two devices and compared simultaneously at 3-minute intervals. The Bland–Altman plot was used to evaluate the agreement between bioreactance and thermodilution. Clinically acceptable agreement was defined as a percentage error of limits of agreement <30%. The four quadrant plot was used to evaluate concordance between bioreactance and thermodilution. Clinically acceptable concordance was defined as a concordance rate >92%.ResultsA total of 2640 datasets were collected. The mean CO difference between the two techniques was 0.9 l/min, and the 95% limits of agreement were -3.5 l/min and 5.4 l/min with a percentage error of 53.9%. The percentage errors in the dissection, anhepatic, and reperfusion phase were 50.6%, 56.1%, and 53.5%, respectively. The concordance rate between the two techniques was 54.8%.ConclusionBioreactance and thermodilution failed to show acceptable interchangeability in terms of both estimating CO and tracking CO changes in patients undergoing liver transplantation. Thus, the use of bioreactance as an alternative CO monitoring to thermodilution, in spite of its noninvasiveness, would be hard to recommend in these surgical patients.  相似文献   

7.
1. A thermistor probe designed for determination of renal blood flow in rabbits, consisted of a fast-responding bead thermistor and an injection port which was also used to measure renal venous pressure between injections. 2. By an in vitro calibration system, actual measured flow (Qa) correlates well with the thermodilution calculated flow (Qc), where Qc = 0.99 Qa + 4.9 (r = 0.97, n = 42). 3. The renal blood flow (RBF) as determined by the thermodilution technique in 3 control groups was 53 +/- 3 (8), 60 +/- 6 (8), and 62 +/- 3 (3) ml/min/kidney or about 9% of the cardiac output. 4. Hypovolemia (-10%) reduced RBF by 19% from the control value, whereas, hypervolemia (+10%) did not alter RBF. 5. Smoke-induced apnea resulted in hypertension (+30%) and bradycardia (-39%), and was associated with changes in RBF (-55%) and renal vascular resistance (+183%). 6. We conclude that the local thermodilution technique is a relatively easy and reliable method for estimating RBF in rabbits.  相似文献   

8.
A method is described for comprehensive hemodynamic study of undisturbed baboons (Papio hamadryas) that incorporates cardiac output measurement by thermodilution. Instrumentation includes arterial, aortic, and central venous catheterization by a surgical technique that does not require entry to peritoneal or thoracic cavities. It provides a means for right atrial indicator delivery with aortic temperature recording of thermodilution curves. Accuracy was confirmed by comparison to measurement by Swan-Ganz catheters. Diurnal variations of systemic arterial pressure in long-term study of conscious baboons were shown to result from significant increases in cardiac output by day (P less than 0.001), despite concomitant falls in systemic vascular resistance. The cardiac output values obtained were 0.13 l.min-1.kg-1 at night and 0.16 l.min-1.kg-1 by day. Comparison of these results to previous reports of cardiac output in baboons highlights the inadequacies of methods that require physical restraint or anesthesia. This technique also leaves the baboons intact for subsequent breeding or experimental use after catheter removal without the need for further surgery.  相似文献   

9.
A new method has been developed for the continuous measurement of aortic blood velocity in patients following cardiac surgery. Using an extractable Doppler ultrasound probe placed on the ascending aorta, the changes in aortic velocity were recorded up to 24 h postoperatively, in 14 patients undergoing coronary bypass surgery. Volume flow rate is calculated from the mean velocity, the diameter of the aorta and the angle between the ultrasound beam and the direction of the blood flow, by means of an analogue flow calculator. Estimation of aortic flow showed a correlation of r = 0.79 with cardiac output measured by a thermodilution technique. The main advantage of the system is that it allows continuous monitoring of cardiac output, as well as short and long-term trend analyses, during the early postoperative period.  相似文献   

10.
The systematic evaluation of different transthoracic echocardiographic (TTE) methods to determine cardiac output (CO) and the effect of changes in intravascular volume on echocardiographically determined indexes of cardiovascular structure in the rat has not been documented. With the use of 11 Wistar rats, simultaneous echocardiographic and thermodilution measurements of CO were compared at baseline and after blood withdrawal or transfusion at 43 different levels of intravascular volume and using 10 different echocardiographic approaches. The best correlation (r = 0.93; P < 0.0001), least bias (-3 ml/min), and best precision (16 ml/min) between thermodilution and echocardiographic methods were obtained at the level of aortic annulus using pulsed Doppler. In conclusion, CO could be accurately assessed in rats using TTE and pulsed Doppler at the level of the aortic annulus. This annulus was demonstrated to remain stable, but pulmonary annulus, thoracic aorta, mitral valve, and left ventricular diameters were found to be more modifiable during volumic changes.  相似文献   

11.
Transgenic murine models of cardiovascular disease offer great potential insights regarding mechanisms of human disease, but efficient and reliable methods for phenotype evaluation are necessary. We employed non-invasive echocardiography to evaluate hemodynamic parameters in mice, and evaluated statistical reliability of these parameters with respect to anesthesia regimen. Male CF-1 mice received inhaled halothane (0.25-0.75% in 95% O2) or ketamine/xylazine (80/10 mg/kg i.p.) and 2-dimensional, M-mode, and Doppler ultrasound imaging were used to assess cardiac contractility and aortic flow velocities. Halothane was more convenient and reliable with respect to rate of induction, reversal, and control of anesthetic depth. At comparable levels of anesthesia, ketamine/xylazine produced significant reductions in heart rate (308 +/- 14 vs. 501 +/- 14 bpm, p<0.001), left ventricular fractional shortening (41.7 +/- 1.3 vs. 49.3 +/- 1.0%, p<0.001), and cardiac output (7.6 +/- 0.5 vs. 11.5 +/- 0.6 ml/min, p<0.001) when compared to halothane inhalation. No change in stroke volume or peak aortic velocity was observed. Correlation analyses revealed highly significant positive relationships between heart rate and fractional shortening (r=0.61, p<0.002) and cardiac output (r=0.88, p<0.001) but no relation to stroke volume or aortic velocity. Variability of intra-animal and intragroup parameter estimation were frequently 2-fold larger for ketamine/xylazine anesthesia vs. halothane. Statistical power analysis showed the increased measurement error for ketamine/xylazine leads to much larger numbers of mice/group to achieve identical statistical sensitivity. These data further illustrate the feasibility of echocardiography for rapid, non-invasive cardiovascular assessment in mice. However, several obtainable parameters are highly sensitive to both heart rate and anesthetic used and the choice and control of anesthetic are critical for physiologically relevant performance parameters and maximal ability to detect statistical differences among groups. Thus, for these non-invasive studies, inhalation anesthesia with agents such as halothane is superior to anesthesia induced by ketamine/xylazine administration.  相似文献   

12.
The purpose of this study was to evaluate right ventricular (RV) loading and cardiac output changes, by using the thermodilution technique, during the mechanical ventilatory cycle. Fifteen critically ill patients on mechanical ventilation, with 5 cmH(2)O of positive end-expiratory pressure, mean respiratory frequency of 18 breaths/min, and mean tidal volume of 708 ml, were studied with help of a rapid-response thermistor RV ejection fraction pulmonary artery catheter, allowing 5-ml room-temperature 5% isotonic dextrose thermodilution measurements of cardiac index (CI), stroke volume (SV) index, RV ejection fraction (RVEF), RV end-diastolic volume (RVEDV), and RV end-systolic volume (RVESV) indexes at 10% intervals of the mechanical ventilatory cycle. The ventilatory modulation of CI and RV volumes varied from patient to patient, and the interindividual variability was greater for the latter variables. Within patients also, RV volumes were modulated more by the ventilatory cycle than CI and SV index. Around a mean value of 3.95 +/- 1.18 l. min(-1). m(-2) (= 100%), CI varied from 87.3 +/- 5.2 (minimum) to 114.3 +/- 5.1% (maximum), and RVESV index varied between 61.5 +/- 17.8 and 149.3 +/- 34.1% of mean 55.1 +/- 17.9 ml/m(2) during the ventilatory cycle. The variations in the cycle exceeded the measurement error even though the latter was greater for RVEF and volumes than for CI and SV index. For mean values, there was an inspiratory decrease in RVEF and increase in RVESV, whereas a rise in RVEDV largely prevented a fall in SV index. We conclude that cyclic RV afterloading necessitates multiple thermodilution measurements equally spaced in the ventilatory cycle for reliable assessment of RV performance during mechanical ventilation of patients.  相似文献   

13.
It has been reported that both sodium and chloride ions must be ingested to induce the elevated blood pressure of deoxycorticosterone acetate (DOCA)-salt-sensitive hypertension. This study was designed to determine the separate roles of the sodium and chloride ions in the altered hemodynamics underlying the high blood pressure. DOCA pellets (75 mg) were implanted in uninephrectomized rats and the animals were then fed one of four diets: (i) high sodium chloride, (ii) high sodium-low chloride, (iii) high chloride-low sodium, or (iv) low sodium chloride. Blood pressures were measured weekly by tail-cuff plethysmography for 5 weeks and the animals were then subjected to a terminal experiment to measure cardiac output by thermodilution technique, renal blood flow by electromagnetic flow probe, and direct arterial pressure. Blood pressure in the DOCA-high NaCl group was significantly greater (P less than 0.05) compared with that of the DOCA-low NaCl group (160 +/- 3 mm Hg vs 124 +/- 2 mm Hg, respectively) at 5 weeks after treatment; all other groups were not significantly different from the DOCA-low NaCl group. Cardiac output was significantly greater in DOCA-treated rats consuming diets high in sodium (44 +/- 2 ml/min/100 g) or sodium chloride (40 +/- 2 ml/min/100 g) compared with animals consuming low sodium chloride (31 +/- 2 ml/min/100 g; P less than 0.01 for each comparison). Direct intraarterial blood pressure and renal blood flow were used to calculate renal vascular resistance. Renal vascular resistance was increased in those DOCA-treated rats consuming diets high in chloride (42 +/- 3 mm Hg/ml/min/100 g) and high sodium chloride (54 +/- 3 mm Hg/ml/min/100 g) compared with rats consuming low sodium chloride (30 +/- 3 mm Hg/ml/min/100 g; P less than 0.01 for each). It appears that elevations in cardiac output are associated with increased dietary sodium and act in synergy with the elevations in renal vascular resistance associated with increased dietary chloride. Increases in both cardiac output and renal vascular resistance are involved in the maintenance of elevated blood pressure in the DOCA-salt-sensitive model of hypertension.  相似文献   

14.
Cardiac outputs were calculated on eight male college students while walking on a treadmill at controlled heart rate levels. The heart rate levels were maintained through the use of a heart rate controller (Quinton Model AI-607), standard deviations for heart rate in beats/min ranged from +/-2.1 at the heart rate level 110 to +/-3.2 at 170. Test-retest correlations of the cardiac output values at the various heart rate levels were: at heart rate 110, 0.66 after 7 min and 0.85 at 30 min; at heart rate 150, 0.92 after 7 min and 0.68 at 30 min; at heart rate 130, 0.97 after 7 min, and at heart rate 170, 0.85 after 7 min. The calculated cardiac output values when plotted against oxygen uptake compare favorably with published reports. The data collected demonstrate that the CO2-rebreathing method used in the present investigation provides a reliable bloodless technique for determining multiple cardiac output during prolonged work of varied intensities.  相似文献   

15.
We examined the influence of three variables (different breathing circuits, breath selected for analysis, and alveolar dead space ventilation) on the accuracy of noninvasive cardiac output determinations with the Fick CO2 (indirect) equation. We compared noninvasive determinations with invasive thermodilution measurements over a wide range of cardiac outputs in 17 2-mo-old pigs anesthetized with halothane and nitrous oxide and paralyzed with either pancuronium or d-tubocurare. We found that rebreathing and nonrebreathing circuits provide accurate cardiac output determinations and that the optimal breath for analysis with either the rebreathing or nonrebreathing technique appears to depend on the cardiac output. When alveolar dead space was increased by using positional changes and the intracardiac administration of glass beads, there was still a good correlation between noninvasive and invasive cardiac output determinations. We conclude that both rebreathing and nonrebreathing techniques of indirect Fick cardiac output determinations correlate well with thermodilution measures over a wide range of cardiac outputs and alveolar dead space/tidal volume fractions.  相似文献   

16.
This study is to explore the changes of arterial mechanical properties in streptozotocin (STZ)-diabetic rats, based on the exponentially tapered T-tube model. Rats given STZ 65 mg kg(-1)i.v. are compared with untreated weight- and age-matched controls. A high-fidelity pressure sensor and electromagnetic flow probe measured pulsatile pressure and flow waves in the ascending aorta, respectively. Diabetic rats exhibit isobaric vasodilatation that is characterized by an increase in cardiac output and no significant changes in aortic pressure. Total peripheral resistance of diabetic rats is lower than that of weight- and age-matched controls. Diabetic rats have higher total peripheral compliance (2.86+/-0.70 microl mm Hg(-1)) than do weight- (1.77+/-0.34 microl mm Hg(-1)) and age-matched (1.87+/-0.69 microl mm Hg(-1)) controls. Aortic characteristic impedance is reduced from 0.017+/-0.003 mm Hg min kg ml(-1)in weight- and 0.020+/-0.004 mm Hg min kg ml(-1)in age-matched controls to 0.010+/-0.004 mm Hg min kg ml(-1)in diabetic rats. Moreover, diabetic rats show shorter wave transit time in lower body circulation (17.86+/-1.91 ms) than do weight- (20.45+/-1.91) and age-matched (23.05+/-2.04 ms) controls. Under isobaric vasodilatation, the decreased resistance and increased compliance in peripheral circulation suggest that the contractile dysfunction of the smooth muscle cells may occur in resistance arterioles in diabetes. With unaltered aortic pressure, an impairment in aortic distensibility of STZ-diabetic rats is manifest on the reduced wave transit time rather than on the diminished aortic characteristic impedance.  相似文献   

17.
This study presents the comparison of two different noninvasive techniques for the estimation of cardiac output (Q). The two techniques used were transthoracic impedance plethysmography (Z) and the indirect Fick CO2 rebreathing (RB) method. Paired estimates of Q were made on 60 different male subjects at rest and during graded increments of work on a cycle ergometer. The mean resting Q as measured by the Z technique (COZ) was 7.46 +/- 0.35 and 5.96 +/- 0.43 l/min using the RB (CORB) technique. At 200 W the mean COZ was 18.67 +/- 0.72 l/min and the CORB was 23.73 +/- 0.84 l/min. Both the techniques were linearly correlated (R) with O2 consumption; i.e., RZ = 0.752, RRB = 0.855. The difference between these two R values is statistically significant (P less than 0.001). A linear relationship was found between the Z and RB techniques at all work loads (R = 0.75). This study suggests that both techniques are equally as reliable over a large range of work loads, with the Z technique being the simplest and most efficient to implement. It was also found that lung volume had no effect on the calculated COZ.  相似文献   

18.
In order to evaluate hemodynamics and blood flow during rest-associated apnea in young elephant seals (Mirounga angustirostris), cardiac outputs (CO, thermodilution), heart rates (HR), and muscle blood flow (MBF, laser Doppler flowmetry) were measured. Mean apneic COs and HRs of three seals were 46% and 39% less than eupneic values, respectively (2.1+/-0.3 vs. 4.0+/-0.1 mL kg(-1) s(-1), and 54+/-6 vs. 89+/-14 beats min(-1)). The mean apneic stroke volume (SV) was not significantly different from the eupneic value (2.3+/-0.2 vs. 2.7+/-0.5 mL kg(-1)). Mean apneic MBF of three seals was 51% of the eupneic value. The decline in MBF during apnea was gradual, and variable in both rate and magnitude. In contrast to values previously documented in seals during forced submersions (FS), CO and SV during rest-associated apneas were maintained at levels characteristic of previously published values in similarly-sized terrestrial mammals at rest. Apneic COs of such magnitude and incomplete muscle ischemia during the apnea suggest that (1) most organs are not ischemic during rest-associated apneas, (2) the blood O(2) depletion rate is greater during rest-associated apneas than during FS, and (3) the blood O(2) store is not completely isolated from muscle during rest-associated apneas.  相似文献   

19.
The importance of cardiac output (CO) to blood pressure level during vasovagal syncope is unknown. We measured thermodilution CO, mean blood pressure (MBP), and leg muscle mean sympathetic nerve activity (MSNA) each minute during 60 degrees head-up tilt in 26 patients with recurrent syncope. Eight patients tolerated tilt (TT) for 45 min (mean age 60 +/- 5 yr) and 15 patients developed syncope during tilt (TS) (mean age 58 +/- 4 yr, mean tilt time 15.4 +/- 2 min). In TT patients, CO decreased during the first minute of tilt (from 3.2 +/- 0.2 to 2.5 +/- 0.3 l x min(-1) x m(-2), P = 0.001) and thereafter remained stable between 2.5 +/- 0.3 (P = 0.001) and 2.4 +/- 0.2 l x min(-1) x m(-2) (P = 0.004) at 5 and 45 min, respectively. In TS patients, CO decreased during the first minute (from 3.3 +/- 0.2 to 2.7 +/- 0.1 l x min(-1) x m(-2), P = 0.02) and was stable until 7 min before syncope, falling to 2.0 +/- 0.2 at syncope (P = 0.001). Regression slopes for CO versus time during tilt were -0.01 min(-1) in TT versus -0.1 l x min(-1) x m(-2) x min(-1) in TS (P = 0.001). However, MBP was more closely correlated to total peripheral resistance (R = 0.56, P = 0.001) and MSNA (R = 0.58, P = 0.001) than CO (R = 0.32, P = 0.001). In vasovagal reactions, a progressive decline in CO may contribute to hypotension some minutes before syncope occurs.  相似文献   

20.
The goal of the present study was to assess the effects of left ventricular (LV) pacing sites (apex vs. free wall) on radial synchrony and global LV performance in a canine model of contraction dyssynchrony. Ultrasound tissue Doppler imaging and hemodynamic (LV pressure-volume) data were collected in seven anesthetized, opened-chest dogs. Right atrial (RA) pacing served as the control, and contraction dyssynchrony was created by simultaneous RA and right ventricular (RV) pacing to induce a left bundle-branch block-like contraction pattern. Cardiac resynchronization therapy (CRT) was implemented by adding simultaneous LV pacing to the RV pacing mode at either the LV apex (CRTa) or free wall (CRTf). A new index of synchrony was developed via pair-wise cross-correlation analysis of tissue Doppler radial strain from six midmyocardial cross-sectional regions, with a value of 15 indicating perfect synchrony. Compared with RA pacing, RV pacing significantly decreased radial synchrony (11.1 +/- 0.8 vs. 4.8 +/- 1.2, P < 0.01) and global LV performance (cardiac output: 2.0 +/- 0.3 vs. 1.4 +/- 0.1 l/min and stroke work: 137 +/- 22 vs. 60 +/- 14 mJ, P < 0.05). Although both CRTa and CRTf significantly improved radial synchrony, only CRTa markedly improved global function (cardiac output: 2.1 +/- 0.2 l/min and stroke work: 113 +/- 13 mJ, P < 0.01 vs. RV pacing). Furthermore, CRTa decreased LV end-systolic volume compared with RV pacing without any change in LV end-systolic pressure, indicating an augmented global LV contractile state. Thus, LV apical pacing appears to be a superior pacing site in the context of CRT. The dissociation between changes in synchrony and global LV performance with CRTf suggests that regional analysis from a single plane may not be sufficient to adequately characterize contraction synchrony.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号