首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A surface plasmon resonance (SPR) based immunosensor has been developed for the monitoring of environmentally persistent pollutants like DDT, its metabolites and analogues in real water samples. A reusable immunosurface is provided via the covalent attachment of the analyte derivative to a self-assembled alkanethiol monolayer formed onto the SPR gold-thin layer. The regeneration of the sensor surface allowed the performance of 270 assay cycles within an analysis time of 20 min for each assay cycle. Immunoassays based on a binding inhibition format were performed by using two monoclonal antibodies (MAbs) with different selectivity. Low limits of detection (LODs), in the sub-nanogram per litre range, were attained for DDT-selective (15 ng L-1) and DDT group-selective immunoassays (31 ng L-1). Both assays were carried out in spiked river water samples without significant effect of the matrix. SPR measurements were validated using gas-chromatography-mass spectrometry. The comparison between methods was in good agreement showing an excellent correlation coefficient (r2=0.995). The SPR analysis of DDT proved to be three times more sensitive than colorimetric ELISAs without the need of labelling and a much lower time of response. Our SPR biosensor portable platform (beta-SPR) is already commercialised by the company SENSIA, S.L. (Spain).  相似文献   

2.
A biosensor based on surface plasmon resonance (SPR) is developed for the detection of 2-hydroxybiphenyl (HBP). A monoclonal antibody against HBP (abbreviated hereafter as HBP-mAb) is developed and used for the detection of HBP by competitive SPR-based immunoassay and enzyme linked immunosorbent assay (ELISA) methods. A novel HBP-hapten compound, HBP-bovine serum albumin conjugate (HBP-BSA), derived by binding several HBP units with BSA by an aliphatic chain spacer is used in the development of antibody and for the functionalization of immunoprobes. HBP-BSA linked to the Au surface of the SPR sensor chip undergoes inhibitive immunoreaction with HBP-mAb in the presence of free HBP. The SPR-based immunoassay provides a rapid determination (response time: approximately 20 min) of the concentration of HBP in the range of 0.1-1000 ppb (ng/ml). Regeneration of the sensor chip is gained by treating the antibody-anchored SPR sensor chip with a pepsin solution (100 ppm (microg/ml); pH 2.0) for few minutes. The SPR sensor chip is reusable for the detection of HBP for more than 20 cycles with average loss of 0.35% reactivity per regeneration step. HBP concentration is determined as low as 0.1 and 3 ppb using the SPR sensor and ELISA measurements, respectively. The developed SPR sensor for HBP is free from interference by coexisting benzo[a]pyrene (BaP), 2,4-dichlorophenoxyacetic acid (2,4-D) and benz[a]anthracene; SPR angle shift obtained to the flow of HBP is almost same irrespective to the presence or absence of a same concentration of these carcinogenic polycyclic aromatic hydrocarbons together. The SPR sensor for HBP is proved to be applicable in simultaneous detection of HBP and BaP in parallel with another SPR sensor for BaP.  相似文献   

3.
A SPR-based immunosensor for the detection of isoproturon   总被引:1,自引:0,他引:1  
The proof of principle of a reusable surface plasmon resonance (SPR)-based immunosensor for the monitoring of isoproturon (IPU), a selective and systemic herbicide, is presented. The detecting rat monoclonal anti-isoproturon antibody (mAb IOC 7E1) was reversibly immobilized through the use of a capture mouse anti-rat (kappa-chain) monoclonal antibody (mAb TIB 172), which was covalently immobilized on the sensor chip surface. Such strategy features a controlled binding of the captured detecting antibody as well as facilitates the surface regeneration. The capture of the anti-IPU mAb by the antibody (TIB 172) coated sensor surface could be carried out up to 120 times (immobilization/regeneration cycles) without any evidence of activity loss. With a high test midpoint and a low associated SPR signal, the direct detection format was shown to be unsuitable for the routine analysis of isoproturon. However, the limit of detection (LOD) could be easily enhanced by using a strategy based on a surface competition assay, which improved all immunosensor parameters. Moreover, the sensitivity and working range of the indirect format were found to be dependent on the surface density of the anti-IPU mAb IOC 7E1. As expected for competitive formats, the lowest surface coverage (0.5 ng/mm(2)) allowed a lower detection of the herbicide isoproturon with a calculated LOD of 0.1 microg/l, an IC(50) (50% inhibition) of 5.3+/-0.6 microg/l, and a working range (20-80% inhibition) of 1.3-16.3 microg/l.  相似文献   

4.
A fiber-optic biosensor for the detection and determination of the pesticides carbaryl and dichlorvos was developed. The sensing bioactive material was a three-layer sandwich. The enzyme cholinesterase was immobilized on the outer layer, consisting of hydrophilic modified polyvinylidenefluoride membrane. The membrane was in contact with an intermediate sol-gel layer that incorporated bromcresol purple, deposited on an inner glass disk. The sensor operated in a static mode at room temperature and the rate of the inhibited reaction served as an analytical signal. Calibration curves were obtained for carbaryl and dichlorvos, with useful concentration ranges 0.11-8.0 mg l(-1) for carbaryl and 5.0-30 microg l(-1) for dichlorvos. The respective detection limits were 108 microg l(-1) and 5.2 microg l(-1). The method reproducibility was in the order of +/-3-5%. The method was successfully applied to the detection and determination of these pesticides in real water samples, without sample preparation steps. Recovery experiments were made and the accuracy of the method was 94.9%. No enzyme regeneration steps were applied and the sensor lifetime was 3 weeks (30% activity reduction). The bioactive mini sandwich can easily be replaced by simply unscrewing the terminal holding ring of the probe and placing a new sandwich, before the sensor is ready for use.  相似文献   

5.
Surface plasmon resonance (SPR) biosensors offer the capability for continuous real-time monitoring. The commercial instruments available have been large in size, expensive, and not amenable to field applications. We report here an SPR sensor system based on a prototype two-channel system similar to the single channel Spreeta devices. This system is an ideal candidate for field use. The two-channel design provides a reference channel to compensate for bulk refractive index (RI), non-specific binding and temperature variations. The SPR software includes a calibration function that normalizes the response from both channels, thus enabling accurate referencing. In addition, a temperature-controlled enclosure utilizing a thermo-electric module based on the Peltier effect provides the temperature stability necessary for accurate measurements of RI. The complete SPR sensor system can be powered by a 12V battery. Pre-functionalized, disposable, gold-coated thin glass slides provide easily renewable sensor elements for the system. Staphylococcus aureus enterotoxin B (SEB), a small protein toxin was directly detectable at sub-nanomolar levels and with amplification at femtomolar levels. A regeneration procedure for the sensor surface allowed for over 60 direct detection cycles in a 1-month period.  相似文献   

6.
A surface plasmon resonance (SPR) assay without surface regeneration was developed for rapid and sensitive detection of chloramphenicol (CAP). A CAP-amine derivative was synthesized using a polyethylene glycol chain attached to the CAP through a carbamate linkage and immobilized onto a Biacore dextran surface. This chemically modified surface significantly changed the binding behavior between antibody and CAP, shown by both fast association and fast dissociation rates, and created a rapid and sensitive SPR immunoassay of the CAP without any regeneration. The limits of detection achieved for CAP were 32.2 pg/ml in aqueous buffer and 42.4 pg/ml in honey-spiked samples.  相似文献   

7.
A competitive immunoassay based on surface plasmon resonance (SPR) for the detection of the pesticide 2,4-dichlorophenoxyacetic acid (2,4-D) is reported. The novelty of the assay is based on the regeneration of the chip surface by the reversible interaction between monosaccharide (D-glucose) and lectin (Concanavalin A). Concanavalin A-2,4-D conjugate was chemically synthesized, purified and used for binding to the SPR chip modified with covalently bound alpha-D-glucose. The interaction between anti-2,4-D antibody and the surface-bound concanavalin A-2,4-D conjugate was monitored by surface plasmon resonance and the response was used for the quantification of 2,4-D. The dynamic range of the calibration curve was between 3 and 100 ng/ml. The demonstrated principle of surface regeneration based on the reversible sugar-lectin interaction may be of more general applicability in immunoassays.  相似文献   

8.
Sandwich and colloidal Au techniques for enhancing the sensitivity of a wavelength-modulation surface plasmon resonance (SPR) immunosensor are demonstrated by the detection of human complement factor 4 (C4). The design of the wavelength-modulation SPR biosensor is based on fixing the incident angle of light and measuring the reflected intensity of light in the wavelength range spanning 500-900 nm simultaneously. The human C4 had good response in the concentration range 2-20 microg/mL in the direct assay. However, in the sandwich assay, the human C4 had good response in the concentration range 0.2-20 microg/mL and the lowest concentration is 10-fold lower than that obtained by the direct assay. With human C4-Au colloidal conjugate, the human C4 had good response in the concentration range 0.1-20 microg/mL and the lowest concentration is 20-fold lower than that obtained by the direct assay. In the colloidal-Au-enhanced sandwich assay, the human C4 had good response in the concentration range 0.05-5 microg/mL and the lowest concentration is 40-fold lower than that obtained by the direct assay. Under selected experimental conditions, the reproducibility, sensitivity, and reversibility of the enhanced SPR immunoassay are very satisfactory. The results represent potentially significant advantages in the sensitivity of SPR biosensors.  相似文献   

9.
An immunosensor based on surface plasmon resonance imaging (SPR imaging) using a specific monoclonal antibody 11E5 (MAb 11E5) was developed for the detection of the seed-borne bacterium Acidovorax avenae subsp. citrulli (Aac), which causes fruit blotch in watermelons and cantaloupes, and compared to the conventional ELISA technique. The 1:40 mixed self-assembled monolayer (mixed SAM) surface was used for the immobilized MAb 11E5 on sensor surface for the detection of Aac. Both whole cells and broken cells of Aac were tested by using direct and sandwich detection assay. The limit of detection (LOD) of Aac using the SPR imaging technique and a direct detection assay was 10(6)cfu/ml and a subsequent amplification of the SPR signal using a polyclonal antibody (PAb) lowered the LOD to 5×10(5) cfu/ml. The LOD for the ELISA technique was 5×10(4) cfu/ml for the detection of Aac, which was slightly better than that for the SPR technique. However, the sensor surface based on SPR imaging offered a major advantage in terms of surface regeneration, allowing at least five cycles with a shorter time assay, multi-channel analysis with an application on multiplex detection, and an ease of the surface usage for the detection of Aac in the naturally infected plant. The surface was tested against the naturally infected sample and showed good selectivity toward the Aac bacteria.  相似文献   

10.
In this study, we attempted to develop a surface plasmon resonance (SPR)-based immunoassay sensor to detect alpha-fetoprotein (AFP) in human plasma at the nanogram level, as is required for clinical diagnosis of hepatocellular tumors. A self-assembled monolayer (SAM) surface of tri(ethylene glycol) (TEG) and carboxyl group-terminated hexa(ethylene glycol) (HEG) was employed to suppress the nonspecific adsorption of plasma components onto the sensor surface. AFP was detected by a sandwich-type immunoassay using two kinds of antibodies, primary and secondary, in this system. The SPR signal shift was further enhanced by applying an antibody (polyclonal) against the second antibody. With this method, the SPR signals were highly intensified, and so nanogram levels (ng/ml) of AFP could be easily detected with a high signal/noise ratio, as is necessary for clinical diagnosis. It is expected that our SPR-based immunoassay method can also be applicable to the detection of several other tumor markers that are present in low concentrations in human blood.  相似文献   

11.
The response of optical fiber surface plasmon resonance (SPR) sensor to potential is monitored in real time. The potential-induced reflectance of a gold-coated optical fiber SPR probe is dependent on potential step width and ionic strength. Wider potential step and stronger ionic strength are generally able to enhance the reflectance and accelerate the response time. The specifically adsorptive anion Cl? provides a pronounced effect on a potential-dependent SPR probe. The exclusive contact of the SPR probe with anion Cl? could significantly slow down the optical response. The work offers opportunities for optical fiber SPR probes to characterize the electrochemical application.  相似文献   

12.
For the quantitative evaluation of low levels of an estriol metabolite of estriol (estriol-16-glucuronide (E3-16G)) in liquid media, we developed a simple and highly sensitive immunoassay using a surface plasmon resonance (SPR) biosensor which did not require any time-consuming sample pretreatment steps. E3-16G was conjugated to ovalbumin (OVA) through an oligoethylene glycol (OEG) linker to form protein conjugates (E3-16G-OEG-OVA), which were then immobilized on a carboxymethyl dextran-coated sensor chip via amine coupling to develop inhibition immunoassays. A limit of detection (LOD) of 76 pg/mL was achieved using a rabbit anti-sheep primary antibody as a binding agent. The detection limit was further improved by using synthesized gold colloids (15 nm) as high mass labels conjugated to the primary antibody. In this Au nanoparticle-enhanced assay, the concentration of E3-16G in aqueous samples could be determined in 7.5 min at a level as low as 14 pg/mL. In addition, the high stability of the E3-16G-OEG-OVA surface gave no obvious drop in antibody-binding capability after more than 1000 binding/regeneration cycles which significantly lowered the research cost.  相似文献   

13.
We have developed a sensitive and specific method based on surface plasmon resonance (SPR) for detection of insulin autoantibodies (IAA) in serum samples from individuals at high risk of developing type 1 diabetes (T1D). When measuring trace molecules in undiluted sera with label-free techniques like SPR, non-specific adsorption of matrix proteins to the sensor surface is often a problem, since it causes a signal that masks the analyte response. The developed method is an indirect competitive immunoassay designed to overcome these problems. Today, IAA is mainly measured in radio immunoassays (RIAs), which are time consuming and require radioactively labeled antigen. With our SPR-based immunoassay the overall assay time is reduced by a factor of >100 (4 days to 50min), while sensitivity is maintained at a level comparable to that offered by RIA.  相似文献   

14.
Mitchell JS  Wu Y  Cook CJ  Main L 《Steroids》2006,71(7):618-631
Thioether-linked 3-mercaptopropionic acid derivatives of 17beta-estradiol and estrone were formed at the A-ring 4-position of the steroids by substitution of their 4-bromo analogues. The carboxylic acid terminal was used to link to an oligoethylene glycol (OEG) chain of 15-atoms in length. The OEG derivative of 17beta-estradiol was then in situ immobilized on a carboxymethylated dextran-coated gold sensor surface used to detect refractive index changes upon protein binding to the surface by surface plasmon propagation in a BIAcore surface plasmon resonance (SPR) instrument. Two other estradiol-OEG derivatives with Mannich reaction linkage at the 2-position and hemisuccinate linkage at the 3-position were also immobilized on the sensor surfaces for comparison. Binding performance between these immobilized different positional conjugates and monoclonal anti-estradiol antibody, raised from a 6-position conjugate, clearly demonstrated that both 2- and 4-conjugates, not conjugated through existing functional groups, gave strong antibody bindings, whereas the 3-conjugate through an existing functional group (3-OH) gave very little binding (2% compared to the 2-conjugate). Both 2- and 4-position conjugates were then applied in a highly sensitive estradiol SPR immunoassay with secondary antibody mediated signal enhancement that gave up to a 9.5-fold signal enhancement of primary antibody binding, and a detection limit of 25 pg/mL was achieved for a rapid and convenient flow-through immunoassay of estradiol.  相似文献   

15.
The Plasmonic surface plasmon resonance (SPR) device was used to develop a rapid, simple and specific immunoassay for detection of Salmonella in milk. Rapid detection of Salmonella contamination is a major challenge for the food industry. Salmonella contamination is well known in all foods including pasteurised milk. The SPR assay was developed as a sandwich model using a polyclonal antibody against Salmonella as capture and detection antibody. Milk spiked with Salmonella typhimurium cells, killed by thimerosal (1%, w/w) treatment was used. Using the Plasmonic SPR assay it was possible to detect S. typhimurium down to a concentration of 1.25 x 10(5) cells ml(-1) in both milk and buffer system. The results obtained are comparable with existing, approved rapid Salmonella detection techniques. No negative effects on the sensitivity of the assay are encountered due to the milk matrix. Hence, no sample preparation or clean-up steps are required. The sample volume requirement for the assay is only 10 microl. Using the assay S. typhimurium was detected in milk within 1h, whereas the cultural techniques require 3-4 days for presumptive positive isolates and further time for confirmation. The rapid tests require at least 24h for the results. The Plasmonic SPR device operates on the Kretschmann configuration and is a cuvette-based system with the advantage of having eight channels on one single SPR chip.  相似文献   

16.
Soluble oligomers of the amyloid-β (Aβ) peptide play a key role in the pathogenesis of Alzheimer's disease, but their elusive nature makes their detection challenging. Here we describe a novel immunoassay based on surface plasmon resonance (SPR) that specifically recognizes biologically active Aβ oligomers. As a capturing agent, we immobilized on the sensor chip the monoclonal antibody 4G8, which targets a central hydrophobic region of Aβ. This SPR assay allows specific recognition of oligomeric intermediates that rapidly appear and disappear during the incubation of synthetic Aβ(1-42), discriminating them from monomers and higher order aggregates. The species recognized by SPR generate ionic currents in artificial lipid bilayers and inhibit the physiological pharyngeal contractions in Caenorhabditis elegans, a new method for testing the toxic potential of Aβ oligomers. With these assays we found that the formation of biologically relevant Aβ oligomers is inhibited by epigallocatechin gallate and increased by the A2V mutation, previously reported to induce early onset dementia. The SPR-based immunoassay provides new opportunities for detection of toxic Aβ oligomers in biological samples and could be adapted to study misfolding proteins in other neurodegenerative disorders.  相似文献   

17.
We have examined the sensing characteristics of a surface plasmon resonance (SPR) immunoassay for the detection of 2,4,6-trinitrotoluene (TNT) using an immunoreaction between 2,4,6-trinitrophenol-ovalbumin (TNP-OVA) conjugate and anti-2,4,6-trinitrophenol antibody (anti-TNP antibody). TNP-OVA conjugate was attached to a SPR-gold sensing surface by means of physical immobilization, which undergoes binding interaction with anti-TNP antibody. Both the immobilization and binding processes were studied from a change in the SPR-resonance angle. The quantification of TNT is based on the principle of indirect competitive immunoassay, in which the immunoreaction between the TNP-OVA conjugate and anti-TNP antibody was inhibited in the presence of free TNT in solution. The decrease in the resonance angle shift is proportional to an increase in concentration of TNT used for incubation. The immunoassay exhibited excellent sensitivity for the detection of TNT in the concentration range from 0.09 to 1000 ng/ml with good stability and reproducibility. The immunosensor developed could detect TNT as low as 0.09 ng/ml, within a response time of approximately 22 min. The sensor surface was regenerated by a brief flow of pepsin solution, which disrupts the antigen-antibody complex without destroying the conjugate biofilm. Cross-reactivity of the SPR sensor to some structurally related nitroaromatic derivative and the detection of TNT in the presence of these nitroaromatic compounds were investigated. The cross-reactivity of the SPR sensor to 2,4-dinitrotoluene (2,4-DNT), 1,3-dinitrobenzene (1,3-DNB), 2-amino-4,6-dinitrotoluene (2A-4,6-DNT) and 4-amino-2,6-dinitrotoluene (4A-2,6-DNT) were very low (< or =1.1%). The analytical characteristics of the proposed immunosensor are highly promising for the development of new field-portable sensors for on-site detection of landmines.  相似文献   

18.
Sensitive and rapid detection of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) was achieved with a newly developed evanescent wave all-fiber immunosensor (EWAI). A reusable functional sensing surface of the immunosensor is prepared by covalent binding of 2,4-D-bovine serum albumin (2,4-D-BSA) conjugate to a self-assembled alkanethiol monolayer formed onto the fiber optic probe through heterobifunctional reagent. The quantification of free 2,4-D in samples was based on indirect competitive immunoreaction principle. Under optimum conditions, calibration curve obtained for 2,4-D had detection limits of 0.07 microg L(-1), the 50% inhibition concentration (IC(50)) was 3.93+/-0.03 microg L(-1) and the quantitative detection range was 0.22-69.5 microg L(-1). The antibodies binding on the sensor surface could be removed simply by the flow of a pepsin solution (pH 1.9), facilitating reuse of the same probe. The regeneration of the sensor surface allowed the performance of more than 100 assay cycles without significant loss of reactivity. The antibody showed negligible cross-reactivity against a few compounds structurally similar to 2,4-D. The immunosensor developed was successfully applied to the monitoring of 2,4-D in spiked water samples without significant effect of the matrix. The proposed portable immunosensor is promising for real-time on-site analysis of small molecules of environmental interest.  相似文献   

19.
For the quantitative evaluation of low levels of an estriol metabolite of estriol (estriol-16-glucuronide (E3-16G)) in liquid media, we developed a simple and highly sensitive immunoassay using a surface plasmon resonance (SPR) biosensor which did not require any time-consuming sample pretreatment steps. E3-16G was conjugated to ovalbumin (OVA) through an oligoethylene glycol (OEG) linker to form protein conjugates (E3-16G-OEG-OVA), which were then immobilized on a carboxymethyl dextran-coated sensor chip via amine coupling to develop inhibition immunoassays. A limit of detection (LOD) of 76 pg/mL was achieved using a rabbit anti-sheep primary antibody as a binding agent. The detection limit was further improved by using synthesized gold colloids (15 nm) as high mass labels conjugated to the primary antibody. In this Au nanoparticle-enhanced assay, the concentration of E3-16G in aqueous samples could be determined in 7.5 min at a level as low as 14 pg/mL. In addition, the high stability of the E3-16G-OEG-OVA surface gave no obvious drop in antibody-binding capability after more than 1000 binding/regeneration cycles which significantly lowered the research cost.  相似文献   

20.
A novel sensing method based on surface plasmon resonance (SPR) was developed for the highly sensitive quantification of low molecular weight (LMW) analytes (colloidal Au replacement assay). Gold nanoparticles (diameter = 20 nm) functionalized with lactosyl-poly(ethylene glycol) (PEG) were prepared and were specifically adsorbed onto a Ricinus communis agglutinin (RCA120)-immobilized SPR sensor chip surface. Subsequent injection of free d-galactose elicited the elution of the preadsorbed lactosyl-PEGylated gold nanoparticles in a manner proportional to the galactose concentration, achieving a substantial and quantitative analysis over a wide range of galactose concentrations (0.1-50 ppm). This method of d-galactose sensing through the substituted elution of preadsorbed nanoparticles from the sensor chip surface would be applicable for the highly sensitive SPR quantification of various LMW analytes, which are known to be difficult to detect by the conventional SPR sensing regime.  相似文献   