首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In order to discriminate selegiline (SG) use from methamphetamine (MA) use, the urinary metabolites of SG users have been investigated using high-performance liquid chromatography (HPLC)–electrospray ionization mass spectrometry (HPLC–ESI–MS). Selegiline-N-oxide (SGO), a specific metabolite of SG, was for the first time detected in the urine, in addition to other metabolites MA, amphetamine (AP) and desmethylselegiline (DM-SG). A combination of a Sep-pak C18 cartridge for the solid-phase extraction, a semi-micro SCX column (1.5 mm I.D.×150 mm) for HPLC separation and ESI–MS for detection provided a simple and sensitive procedure for the simultaneous determination of these analytes. Acetonitrile–10 mM ammonium formate buffer adjusted to pH 3.0 (70:30, v/v) at a flow-rate of 0.1 ml/min was found to be the most effective mobile phase. Linear calibration curves were obtained over the concentration range from 0.5 to 100 ng/ml for all the analytes by monitoring each protonated molecular ion in the selected ion monitoring (SIM) mode. The detection limits ranged from 0.1 to 0.5 ng/ml. Upon applying the scan mode, 10–20 ng/ml were the detection limits. Quantitative investigation utilizing this revealed that SGO was about three times more abundant (47 ng/ml, 79 ng/ml) than DM-SG in two SG users’ urine samples tested here. This newly-detected, specific metabolite SGO was found to be an effective indicator for SG administration.  相似文献   

2.
A rapid liquid chromatography–electrospray mass spectrometry (LC–ES-MS) method with in vivo microdialysis for the determination of free-form of cocaine (COC) in rat brain has been developed. A C18 column and a gradient elution were employed for the separation. The [M+H]+ (m/z=304) and a fragmented ion (m/z=182) were detected using positive ion mode detection. Selective ion monitoring was utilized for quantitative measurement. The linearity of this assay was good ranging from 0.01 to 1.0 μM (r2=0.999). The inter- and intra-day precisions showed relative standard deviations ranging from 1.0% to 3.3% and 1.0% to 3.6%, respectively. In addition, the detection of one COC metabolite, benzoylecgonine (BE), by this assay was also investigated. The linearity, precision, and detection limit associated with this method for BE were determined. The application of this newly developed method was demonstrated by examining the pharmacokinetics of COC in rat brain.  相似文献   

3.
For the highly sensitive and selective determination of NE-100, a novel sigma ligand, at levels of low picogram per milliliter of human plasma, a method with excellent reliability employing liquid chromatography (LC)–electrospray ionization (ESI) tandem mass spectrometry (MS–MS) combined with a column-switching technique has been developed. The method involves the use of a stable isotope labeled compound as the internal standard (I.S.), liquid–solid extraction of a plasma specimen with a C8 cartridge, automated on-line clean-up on a short trapping column, subsequent separation on a micro-bore C18 column and detection with ESI-MS–MS using m/z 356 ([M+H]+) as a precursor ion and m/z 105 as a product ion in a selected reaction monitoring mode. The detection and the quantification limits of NE-100 in plasma were 0.5 pg/ml with a signal-to-noise ratio (S/N) of 3 and 2.3 pg/ml, respectively, with an S/N of 21. The good linearity of the calibration graph was obtained in the range of 2.3∼907.0 pg/ml with excellent reliability. The developed method was applied to the determination of NE-100 in plasma obtained from the clinical trail.  相似文献   

4.
The aim of the project was to develop a fast and reliable method for the quantification of the three tetracyclines: tetracycline, oxytetracycline and chlortetracycline in urine. The method is based on column-switching high-performance liquid chromatography with detection by MS–MS. Buffer is added to the sample before it is injected into the chromatographic system, and the first column which is an internal surface reversed-phase column separates the tetracyclines from the bulk of other compounds in urine. The tetracyclines are collected and concentrated on the analytical column before they are separated and eluted into the mass spectrometer in which the tetracycline are detected. The mass spectrometer is a triple quadrupole instrument and is equipped with an electrospray ion source. The MH+ ions are selected in the first quadrupole and collisionally activated in the collision cell. Upon collision, activation all three tetracyclines form fragment ions which could be assigned as: [M+H–H2O–NH3]+ which are selected in the sond mass filter. The detection limits for all three tetracyclines are about 10 ppb, and the calibration curves are linear from 10 to 1000 ppb.  相似文献   

5.
High-performance liquid chromatography with electrospray ionization mass spectrometry was used to determine 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine. After basic hydrolysis of conjugates, the compound was extracted using SPEC-PLUS-3ML-C18 solid-phase extraction columns. A deuterium labelled internal standard (d3-THC-COOH) was added prior to hydrolysis. Separation was performed on a reversed-phase Zorbax Eclipse XDB-C8 analytical column (150×3.0 mm I.D.) using a gradient program from 60 to 80% acetonitrile (4 mM formic acid) at a flow-rate of 0.5 ml/min. The compounds were detected by single ion monitoring of m/z 345 and m/z 348 for the protonated molecules [THC-COOH+H]+ and [d3-THC-COOH+H]+, respectively. The precision and accuracy were tested on spiked urine samples in the range 2.5–125 ng/ml. The mean recovery was 95% (n=58), coefficients of variations were 2.2–4.3% and the limit of detection 2 ng/ml. Diagnostic qualifying ions of THC-COOH (m/z 327 and m/z 299) and d3-THC-COOH (m/z 330) were generated using up-front collision-induced dissociation. The relative ion intensities in clinical samples (n=21) were within ±20% deviation compared with standards. Using this tolerance and the presence of the ions m/z 327 and m/z 299 at the correct retention times as the acceptance criteria for identification of THC-COOH positive samples, the limit of detection was 15 ng/ml. The LC–MS method complies with the current recommendations on drugs of abuse testing, in which mass spectrometric detection is emphasized.  相似文献   

6.
This paper describes a rapid and sensitive method for the quantitation of 20(S)-protopanaxadiol (PPD) in human plasma based on high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analyte and internal standard (I.S.), ginsenoside Rh2, were extracted from plasma by liquid–liquid extraction and separated on a Zorbax extend C18 analytical column using methanol–acetonitrile-10 mM ammonium acetate (47.5:47.5:5, v/v/v) as mobile phase. Detection was by tandem mass spectrometry using electrospray ionization in the positive ion mode and multiple reaction monitoring (MRM). The assay was linear over the concentration range 0.1–100.0 ng/ml with a limit of detection of 0.05 ng/ml. The method was successfully applied to a clinical pharmacokinetic study in healthy volunteers after a single oral administration of a PPD 25 mg capsule.  相似文献   

7.
A simple liquid chromatography electrospray ionization mass spectrometry (LC–ESI–MS) method with highly improved sensitivities for the determination of helicid in rat bile, urine, feces and most tissues was developed. The tissues and feces were firstly homogenized mechanically using deionized water as the media. Bile, urine, tissues and feces homogenates were extracted by liquid–liquid extraction with n-butyl alcohol for sample preparation. The subsequent analysis procedures were performed on a Shimadzu LCMS2010A system (electrospray ionization single quadrupole mass analyzer). A Luna C18 column (150 mm × 2.00 mm, 5 μm) was used as the analytical column, while a mixture of acetonitrile and ammonium chloride water solution was used as the mobile phase. The proportions of mobile phase were changed timely according to gradient programs. Chlorinated adducts of molecular ions [M+Cl]? at m/z 319.00 and 363.05 were used to quantify helicid and bergeninum (internal standard), respectively. The method was validated to be accurate, precise and rugged with good linearity. The proposed method was successfully applied to the preclinical tissue distribution and excretion studies of helicid in rats.  相似文献   

8.
A liquid chromatography (LC)/electrospray ionization (ESI)-mass spectrometry (MS) method for the direct determination of eighteen tetrahydrocorticosteroid sulfates in human urine has been developed. The analytes were 3- and 21-monosulfates and 3,21-disulfates of tetrahydrocortisol (THF), tetrahydrocortisone (THE), tetrahydro-11-deoxycortisol (THS), and their corresponding 5α-H stereoisomers. The mass spectrometric behavior of these sulfates in negative-ion ESI-MS/MS revealed the production of intense structure specific product ions within the same group of sulfates and permitted distinction between regioisomeric sulfates by collision-induced fragmentation with the MS/MS technique using a linear ion-trap instrument. For the quantitative analysis, selected reaction monitoring analysis in the negative-ion detection mode using triple-stage quadrupole mass spectrometer was performed by monitoring transitions from [M−H] to the most abundant product ion of each tetrahydrocorticosteroid sulfate. After addition of 3- and 21-monosulfates of [2,2,3β,4,4-d5]-THF, -THE, and -THS as internal standards, urine sample was applied to a solid phase extraction using a lipophilic-weak anion exchange cartridge column, and then analyzed by LC/ESI-MS/MS. The method had satisfactory performance in terms of intra- and inter-assay precision (less than 9.7% and 9.6%, respectively), and accuracy (91.2–108.2%). The limit of quantification was lower than 2.5 ng/mL for all sulfates examined. We applied this method to determine the concentration of eighteen tetrahydrocorticosteroid sulfates in the urine of healthy subjects. Thus, we have developed a sensitive, precise and accurate assay for urinary tetrahydrocorticosteroid sulfates that should be useful for clinical and biological studies.  相似文献   

9.
A new sensitive and accurate analytical method has been developed for quantification of intracellular nucleotides in complex biological samples from cultured cells of different microorganisms such as Saccharomyces cerevisiae, Escherichia coli, and Penicillium chrysogenum. This method is based on ion pair reversed phase liquid chromatography electrospray ionization isotope dilution tandem mass spectrometry (IP-LC-ESI-ID-MS/MS. A good separation and low detection limits were observed for these compounds using dibutylamine as volatile ion pair reagent in the mobile phase of the LC. Uniformly 13C-labeled isotopes of nucleotides were used as internal standards for both extraction and quantification of intracellular nucleotides. The method was validated by determining the linearity, sensitivity, and repeatability.  相似文献   

10.
A simple, sensitive and rapid method for the analysis of lumefantrine in rat plasma using liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) was developed. Detection was performed by positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The method included a chromatographic run of 5 min using a C18 analytical column and the calibration curve was linear over the concentration range of 2–500 ng/mL with a correlation coefficient (r) of 0.996 or better. The intra- and inter-day assay precision ranged from 1.5 to 7.5% and 5.5 to 7.7%, respectively, and intra- and inter-day assay accuracy was between 91.3–109.7% and 97.0–104.7%, respectively. The method was successfully applied for the pharmacokinetic study in rats.  相似文献   

11.
A rapid, highly sensitive method for the determination of morphine and its metabolites morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G) and normorphine has been developed using high-performance liquid chromatography–electrospray mass spectrometry, with the deuterated analogues as internal standards. The analytes were extracted automatically using end-capped C2 solid-phase extraction cartridges. Baseline separation of morphine, M3G and M6G was achieved on a LiChrospher 100 RP-18 end-capped analytical column (125×3 mm I.D., 5 μm particle size) with water–acetonitrile–tetrahydrofuran–formic acid (100:1:1:0.1, v/v) as the mobile phase. Morphine and normorphine coeluate and were separated mass spectrometrically. The mass spectrometer was operated in the selected-ion monitoring mode using m/z 272 for normorphine, m/z 286 for morphine, m/z 462 for morphine-6-glucuronide. Due to an interfering peak, M3G was measured by tandem mass spectrometry in the daughter-ion mode. The limits of quantitation achieved with this method were 1.3 pmol/ml for morphine, 1.5 pmol/ml for normorphine, 1.0 pmol/ml for M6G and 5.4 pmol/ml for M3G in serum or cerebrospinal fluid. The limits of quantitation achieved in urine were 10 pmol/ml for morphine, 20 pmol/ml for normorphine and M6G and 50 pmol/ml for M3G using a sample size of 100 μl. The method described was successfully applied to the determination of morphine and its metabolites in human serum, cerebrospinal fluid and urine in pharmacokinetic and drug interaction studies.  相似文献   

12.
A simple, rapid and accurate liquid chromatography–electrospray ionization-tandem mass spectrometry method was developed and validated for quantification of dihydroartemisinin (DHA) in human plasma. Following a simple single-step liquid–liquid extraction with ethyl acetate, the analyte was separated on a C18 column by isocratic elution with methanol–water–10 mM ammonium acetate (80:10:10, v/v/v), and analyzed by mass spectrometry in the positive ion MRM mode. Good linearity was achieved over a wide range of 1.01–2020 ng/mL. Intra- and inter-day precisions were less than 9.0%, and accuracy ranged from 93.0 to 98.2%. The pharmacokinetics of DHA injectable powder was studied for the first time in healthy subjects by this method. After single intravenous infusion of DHA injectable powder 40, 80 and 160 mg, the elimination half-life (t1/2λZ) was 1.69, 1.88 and 1.92 h, respectively; mean Cmax and AUC increased in proportion to the doses. The pharmacokinetics of DHA fit the linear dynamic feature over the DHA dose range studied.  相似文献   

13.
A liquid chromatography–electrospray ionization tandem mass spectrometry (HPLC–ESI-MS/MS) method for the determination of andrographolide in human plasma was established. Dehydroandrographolide was used as the internal standard (I.S.). The plasma samples were deproteinized with methanol and separated on a Hanbon C18 column with a mobile phase of methanol–water (70:30, v/v). HPLC–ESI-MS/MS was performed in the selected ion monitoring (SIM) mode using target ions at [M?H2O–H]?, m/z 331.1 for andrographolide and [M?H]?, m/z 331.1 for the I.S. Calibration curve was linear over the range of 1.0–150.0 ng/mL. The chromatographic separation was achieved in less than 6.5 min. The lower limits of quantification (LLOQ) was 1.0 ng/mL. The intra and inter-run precisions were less than 6.95 and 7.22%, respectively. The method was successfully applied to determine the plasma concentrations of andrographolide in Chinese volunteers.  相似文献   

14.
A fast and efficient multi-residue extraction–purification procedure was developed for 12 corticosteroids in biological matrices (hair, urine and meat), in order to control their illegal use as growth promoters in cattle. Detection and identification of the analytes were achieved using a previously described LC–MS–MS method based on negative electrospray ionisation and a triple quadrupole analyser. The presented procedures included acid (hair) or enzymatic (urine and meat) hydrolysis, C18 reversed-phase SPE, Na2CO3 liquid–liquid clean-up and SiOH normal-phase SPE. The detection limits of the developed methods were between 2.9 and 9.3 pg/mg (ppb) for hair samples and in the 40 – 70 pg/g (ppt) range for the urine or meat samples. The acid hydrolysis used for corticosteroid extraction in hair was optimised using an experimental design and response surface methodology. Achieved performances were linked to a physico–chemical approach based on the corticosteroids specific C17 side-chain. This original multi-residue and multi-matrices analytical methodology will be used for further metabolism studies.  相似文献   

15.
ent-Kaurenoic acid (KA) is a key intermediate connected to a phytohormone gibberellin. To date, the general procedure for quantifying KA is by using traditional gas chromatography–mass spectrometry (GC–MS). In contrast, gibberellins, which are more hydrophilic than KA, can be easily quantified by liquid chromatography-tandem mass spectrometry (LC–MS/MS). In this study, we have established a new method to quantify KA by LC–MS/MS by taking advantage of a key feature of KA, namely the lack of fragmentation that occurs in MS/MS when electrospray ionization (ESI) is in the negative mode. Q1 and Q3 were adopted as identical channels for the multiple reaction monitoring of KA. The method was validated by comparing with the results obtained by selected ion monitoring in GC–MS. This new method could be applicable for the quantification of other hydrophobic compounds.  相似文献   

16.
Quantitative analysis of fatty acids (FAs) is an important area of analytical biochemistry. Ultra high sensitivity FA analysis usually is done with gas chromatography of pentafluorobenzyl esters coupled to an electron-capture detector. With the popularity of electrospray ionization (ESI) mass spectrometers coupled to liquid chromatography, it would be convenient to develop a method for ultra high sensitivity FA detection using this equipment. Although FAs can be analyzed by ESI in negative ion mode, this method is not very sensitive. In this study, we demonstrate a new method of FA analysis based on conversion of the carboxylic acid to an amide bearing a permanent positive charge, N-(4-aminomethylphenyl)pyridinium (AMPP) combined with analysis on a reverse-phase liquid chromatography column coupled to an ESI mass spectrometer operating in positive ion mode. This leads to an ∼60,000-fold increase in sensitivity compared with the same method carried out with underivatized FAs. The new method is about 10-fold more sensitive than the existing method of gas chromatography/electron-capture mass spectrometry of FA pentafluorobenzyl esters. Furthermore, significant fragmentation of the precursor ions in the nontag portion improves analytical specificity. We show that a large number of FA molecular species can be analyzed with this method in complex biological samples such as mouse serum.  相似文献   

17.
To reliably identify the residual tetracycline antibiotics (TCs), oxytetracycline (OTC), tetracycline, chlortetracycline (CTC) and doxycycline (DC), in bovine tissues, we have established a confirmation method using electrospray ionization liquid chromatography–tandem mass spectrometry (ESI LC–MS–MS) with daughter ion scan. All TCs gave [M+H−NH3]+ and [M+H−NH3−H2O]+ as the product ions, except for DC when [M+H]+ was selected as the precursor ion. The combination of C18 cartridge clean-up and the present ESI LC–MS–MS method can reliably identify TCs fortified at a concentration of 0.1 ppm in bovine tissues, including liver, kidney and muscle, and has been successfully applied to the identification of residual OTC in bovine liver and residual CTC in bovine muscle samples previously found at concentrations of 0.58 ppm and 0.38 ppm by LC, respectively.  相似文献   

18.
An original method based upon high-performance liquid chromatography coupled to ionspray mass spectrometry (HPLC–ISP-MS) has been developed for the identification and quantification in plasma of several cardiac glycosides, namely digoxin, digitoxin, lanatoside C and acetyldigitoxin. After single-step liquid–liquid extraction by chloroform–2-propanol (95:5, v/v) at pH 9.5 using oleandrin as an internal standard, solutes are separated on a 4 μm NovaPak C18 (Waters) column (150×2.0 mm, I.D.), using a gradient of acetonitrile–2 mM NH4COOH, pH 3 buffer (flow-rate 200 μl/min, post-column split 1:3). Detection is done by a Perkin-Elmer Sciex API-100 mass analyzer equipped with an ISP interface. In most instances the major ion observed is not [M+H]+ as expected, but [M+NH4]+. The mean retention times (min) are: lanatoside C, 5.74; digoxin, 6.00; digitoxin, 8.08, oleandrin, 8.30, acetyldigitoxin, 8.66 and 9.01 (isomers α and β, respectively). The lower limits of detection in single ion monitoring mode range from 0.15 ng/ml (α- and β-acetyldigitoxin) to 0.60 ng/ml (lanatoside C), making the method less sensitive than radioimmunoassay, whereas it is much more specific.  相似文献   

19.
Introduction – Isodon nervosa is a commonly used traditional Chinese medicine including diterpenoids, phenolic acids, triterpenoids and volatile oil. Qualitative and quantitative analysis of multi‐components is important for its quality control. Objective – To establish a liquid chromatography–electrospray ionisation–mass spectrometry method for simultaneous analysis of 20 bioactive constituents of Isodon nervosa in different places of China and different parts of this herb. Methodology – The optimal chromatographic conditions were achieved on a C18 column (250 × 4.6 mm, 5 µm) with with linear gradient elution with 0.1% aqueous formic acid : methanol containing 0.1% formic acid at a flow‐rate of 0.7 mL/min in 15 min. The identification and quantification of those analytes were achieved on a hybrid quadrupole linear ion trap mass spectrometer. Multiple‐reaction monitoring scanning was employed for quantification with switching electrospray ion source polarity between positive and negative modes in a single run. Full validation of the method was carried out (linearity, precision, accuracy, limit of detection and limit of quantification). Results – The results indicated that the method was simple, rapid, specific and reliable. The proposed method was successfully applied for the qualitative and quantitative analysis of 20 chemical compositions in Isodon nervosa samples. Conclusion – Twenty chemical compositions in 21 batches of wild and cultivated Isodon nervosa samples from different sources had great variation in the contents. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
A liquid chromatographic method with photometric detection for the determination of cilazapril and its active metabolite and degradation product cilazaprilat in urine and pharmaceuticals has been developed. The chromatographic method consisted of a μBondapak C18 column maintained at 30±0.2°C, using a mixture of methanol-10 mM phosphoric acid (50:50 v/v) as mobile phase at a flow-rate of 1.0 ml/min. Enalapril maleate was used as internal standard. The detection was performed at a wavelength of 206 nm. A study of the retention of cilazapril and cilazaprilat using solid–liquid extraction has been carried out in order to optimise the clean-up procedure for urine samples, which consisted of a solid–liquid extraction using C8 cartridges. Recoveries greater than 85% are obtained for both compounds. The method was sensitive, precise and accurate enough to be applied to the determination of urine samples obtained from three hypertensive patients up to 24 h after intake of a therapeutic dose (detection limit of 70 ng/ml for cilazapril and cilazaprilat in urine). A comparison of the method developed using photometric and amperometric detection has been carried out.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号