首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study describes a chromatographic method for the determination of diazepam, an anxiolytic drug that is also used as an antidote against nerve agent seizures, its metabolites N-desmethyldiazepam, and temazepam, the anti-nerve agent drug pyridostigmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) and its metabolite N-methyl-3-hydroxypyridinium bromide in rat plasma and urine. The compounds were extracted using C18 Sep-Pak Vac 3cc (500 mg) cartridges and separated using isocratic mobile phase of methanol, acetonitrile and water (pH 3.2) (10:40:50) at a flow-rate of 0.5 ml/min in a period of 12 min, and UV detection ranging between 240 and 280 nm. The limits of detection for all analytes ranged between 20 and 50 ng/ml, while limits of quantitation were 100 ng/ml. Average percentage extraction recoveries of five spiked plasma samples were 79.1±7.7, 83.5±6.4, 83.9±5.9, 71.3±6.0 and 77.7±5.6, and from urine 79.4±7.9, 83.1±6.9, 73.6±7.7, 74.3±7.1 and 77.6±5.9 for diazepam, N-desmethyldiazepam, temazepam, pyridostigmine bromide, and N-methyl-3-hydroxypyridinium bromide, respectively. The relationship between peak areas and concentration was linear over the range between 100 and 1000 ng/ml. This method was applied to determine the above analytes following a single oral administration in rats as a tool to study the pharmacokinetic profile of each compound, alone and in combination.  相似文献   

2.
A method was developed for the separation and quantification of the insecticide chlorpyrifos (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphorothioate), its metabolites chlorpyrifos-oxon (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphate) and TCP (3,5,6-trichloro-2-pyridinol), the anti-nerve agent drug pyridostigmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide), its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), and its metabolites m-toluamide and m-toluic acid in rat plasma and urine. The method is based on using solid-phase extraction and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 210 and 280 nm. The compounds were separated using a gradient of 1–85% acetonitrile in water (pH 3.20) at a flow-rate ranging between 1 and 1.7 ml/min over a period of 15 min. The retention times ranged from 5.4 to 13.2 min. The limits of detection ranged between 20 and 150 ng/ml, while the limits of quantitation were between 150 and 200 ng/ml. Average percentage recovery of five spiked plasma samples was 80.2±7.9, 74.9±8.5, 81.7±6.9, 73.1±7.8, 74.3±8.3, 80.8±6.6, 81.6±7.3 and 81.4±6.5, and from urine 79.4±6.9, 77.8±8.4, 83.3±6.6, 72.8±9.0, 76.3±7.7, 83.4±7.9, 81.6±7.9 and 81.8±6.8 for chlorpyrifos, chlorpyrifos-oxon, TCP, pyridostigmine bromide, N-methyl-3-hydroxypyridinium bromide, DEET, m-toluamide and m-toluic acid, respectively. The relationship between peak areas and concentration was linear over a range between 200 and 2000 ng/ml.  相似文献   

3.
A rapid and simple method was developed for the separation and quantification of the anti nerve agent drug pyridostignmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), its metabolites m-toluamide and m-toluic acid, the insecticide permethrin (3-(2,2-dichloro-ethenyl)-2,2-dimethylcyclopropanecarboxylic acid(3-phenoxyphenyl)methylester), and two of its metabolites m-phenoxybenzyl alcohol, and m-phenoxybenzoic acid in rat plasma and urine. The method is based on using C18 Sep-Pak® cartridges for solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 208 and 230 nm. The compounds were separated using gradient of 1 to 99% acetonitrile in water (pH 3.20) at a flow-rate ranging between 0.5 and 1.7 ml/min in a period of 17 min. The retention times ranged from 5.7 to 14.5 min. The limits of detection were ranged between 20 and 100 ng/ml, while limits of quantitation were 150–200 ng/ml. Average percentage recovery of five spiked plasma samples were 51.4±10.6, 71.1±11.0, 82.3±6.7, 60.4±11.8, 63.6±10.1, 69.3±8.5, 68.3±12.0, 82.6±8.1, and from urine 55.9±9.8, 60.3±7.4, 77.9±9.1, 61.7±13.5, 68.6±8.9, 62.0±9.5, 72.9±9.1, and 72.1±8.0, for pyridostigmine bromide, DEET, permethrin, N-methyl-3-hydroxypyridinium bromide, m-toluamide, m-toluic acid, m-phenoxybenzyl alcohol and m-phenoxybenzoic acid, respectively. The relationship between peak areas and concentration was linear over the range between 100 and 5000 ng/ml. This method was applied to analyze the above chemicals and metabolites following their administration in rats.  相似文献   

4.
5.
A reversed-phase HPLC method with fluorescence detection was evaluated for utility in determination of urinary metabolites of polycyclic aromatic hydrocarbons as biomarkers of environmental exposure. The method, which was developed for use in studies of high-level occupational exposure, was found to be unreliable for relatively low-level environmental exposures. The method was modified to include quantitation by standard addition in order to compensate for matrix effects at levels as low as 0.1 ng/ml. The standard addition modification increased both qualitative and quantitative performance, with recovery of 1-hydroxypyrene spikes improved from 164% to 114% at 0.36 ng/ml. The modified method was successfully applied in an environmental exposure study.  相似文献   

6.
A direct injection column-switching high-performance liquid chromatography (HPLC) method was developed and validated for quantification of zaltoprofen in rat plasma. Following dilution with mobile phase A, i.e. acetonitrile-10mM potassium phosphate buffer (pH 6.8) (12:88, v/v) samples were directly injected to the pre-column without sample pre-purification step. After endogenous plasma components were eluted to waste, the system was switched and the analyte was eluted to the trap column. Zaltoprofen was then back-flushed to the analytical column for separation with mobile phase B, i.e. acetonitrile-10mM potassium phosphate buffer (pH 6.8) (35:65, v/v) and quantification with an ultraviolet detector at 230 nm. The calibration curve was linear in the concentration range of 40-5000 ngmL(-1). This method has been fully validated and shown to be specific, accurate and precise. The method is simple, rapid and the sample preparation is minimal and appears to be useful for the pharmacokinetic study of zaltoprofen.  相似文献   

7.
Quinupristin–dalfopristin (30:70, w/w) is a new streptogramin, which has been developed for intravenous use. A specific and sensitive HPLC method was developed to measure simultaneously quinupristin (RP 57669) and dalfopristin (RP 54476) and their main metabolites in human plasma. The metabolites measured by this method were RP 69012 (glutathione-conjugated) and RPR 100391 (cysteine-conjugated) from quinupristin and RP 12536 (natural pristinamycin IIA), from dalfopristin. Solid-phase extraction with disposable cartridges was combined with reversed-phase HPLC and fluorimetric detection for RP 57669, RP 69012 and RPR 100391 and UV detection for RP 54476 and RP 12536. The method provided good recovery and low limits of quantitation (0.025 mg l−1 for RP 57669, RP 54476 and RP 12536, and of 0.010 mg l−1 for RP 69012 and RPR 100391). The validated range of concentrations of the method was: 0.025–5000 mg l−1 for RP 57669, RP 54476 and RP 12536 and 0.010–0.750 mg l−1 for RP 69012 and RPR 100391.  相似文献   

8.
A rapid, specific, sensitive and economical method has been developed and validated for the determination of grepafloxacin in human plasma and urine. The assay consisted of reversed-phase HPLC with UV detection. Plasma proteins were removed by a fast and efficient procedure that has eliminated the need for costly extraction and evaporation. For the urine samples, the only required sample preparation was dilution. Separation was achieved on a reversed-phase TSK gel column with an isocratic mobile system. The method had a quantification limit of 0.05 μg/ml in plasma and 0.5 μg/ml in urine. The coefficients of variation (C.V.) were less than 4% for within- and between-day analyses. The method was successfully applied to a pharmacokinetic study, and was proved to be simple, fast and reproducible.  相似文献   

9.
10.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

11.
An isocratic reversed-phase high-performance liquid chromatographic (HPLC) method using an Ultrasphere IP column has been developed for the determination of testosterone and its metabolites after incubation of 4-14C-labelled or unlabelled testosterone with rat liver microsomes. Compounds were eluted with methanol-water-tetrahydrofuran (35:55:10, v/v, pH 4.0) and detected by ultraviolet (UV) absorption at 245 nm. UV or on-line radioactivity detection can be used although, due to differences in detector cell volumes, peak resolution is slightly better with UV detection. Selectivity was validated by collecting HPLC peaks and verifying their identity by gas chromatography-mass spectrometry after derivatization by N,O-bis(trimethylsily)trifluoroacetamide-trimethylchlorosilane. A three-day validation was performed to determine the linearity, repeatability, reproducibility and accuracy of the method, using corticosterone as internal standard. The method is applicable to the measurement of cytochrome P-450 isoenzyme activities in rat liver.  相似文献   

12.
Moguisteine is a novel peripheral non-narcotic antitussive agent. Pharmacokinetic studies in animal and in man showed that no unchanged drug is present in plasma, urine and faeces after oral administration. The main active metabolite, M1, is the free carboxylic acid of moguisteine, which maintains a stereogenic centre and consists of R(+)-M1 and S(−)-M1 enantiomers. M1 is partly metabolized to M2, its sulfoxidation derivative. A conventional HPLC method is described for the simultaneous determination of M1 and M2 in human plasma and urine after administration of therapeutic moguisteine doses. Plasma samples, previously acidified with phosphoric acid, are extracted with dichloromethane; urine samples are analyzed after appropriate dilution with methanol. Chromatography is performed using a Lichrosorb RP2 column and a linear gradient. M1 enantiomers can be determined in plasma extracts and urine samples by a chiral HPLC method using a β-cyclodextrin column. The analytical characteristics of both HPLC procedures proved to be adequate to analyze samples of subjects treated with therapeutic doses of moguisteine during clinical pharmacokinetic studies.  相似文献   

13.
Two high-performance liquid chromatographic methods for the assay of oxmetidine are described: both utilize the same liquid extraction from plasma, urine and bile samples. A normal-phase technique is considered most suitable for the analysis of plasma extracts and a reversed-phase method is preferred for the assay of excretory fluids such as urine and bile which will contain polar metabolites in detectable quantity as well as unchanged oxmetidine.The methods are sensitive enough to follow the kinetic changes in concentration for up to 8 h after the administration of recommended therapeutic doses. Both methods can be automated in respect of the high-performance liquid chromatograph and the samples can be stored for several weeks at −20°C without prejudicing the accuracy of the analysis.  相似文献   

14.
Nitro--arginine (-NNA) is an inhibitor of the enzyme nitric oxide synthase (NOS). We developed a simple, sensitive and reproducible reversed-phase high-performance liquid chromatographic method for detection of nitro-arginine (- and -enantiomer) in rat plasma and urine. Samples were treated with perchloric acid, neutralized and eluted through a C8 reversed-phase column with a mobile phase of 18.5 mM heptanesulfonic acid-10% methanok in water using theophylline as an internal standard. Plasma recovery for both isomers was complete, and the sensitivity limit was 0.5 μg/ml. This method may be used for disposition studies of -NNA in small animals.  相似文献   

15.
An isocratic HPLC method was developed and validated for the quantitation of methocarbamol in human plasma. Methocarbamol and internal standard in 200 μl of human plasma were extracted with ethyl acetate, evaporated to dryness and reconstituted in water. Separation was achieved on a reversed-phase C18 column with a mobile phase of methanol—0.1 M potassium phosphate monobasic—water (35:10:55, v/v/v). The detection was by ultraviolet at 272 nm. Linearity was established at 1–100 μg/ml (r > 0.999). The limit of quantitation was designed as 1 μg/ml to suit pharmacokinetic studies. Inter-day precision and accuracy of the calibration standards were 1.0 to 3.6% coefficients of variance (C.V.) and −2.0 to +1.6% relative error (R.E.). Quality controls of 3, 20 and 70 μg/ml showed inter-day precision and accuracy of 2.5 to 3.6% C.V. and −0.9 to −0.4% R.E. Recovery of methocarbamol was 91.4–100.3% in five different lots of plasma. The method was shown to be applicable on different brands of C18 columns.  相似文献   

16.
A stereospecific method of analysis of racemic isosakuranetin (5,7-dihydroxy-4'-methoxyflavanone) in biological fluids is necessary to study pharmacokinetics. A simple high-performance liquid chromatographic method was developed for the determination of isosakuranetin enantiomers. Separation was achieved on a Chiralpak AD-RH column with ultraviolet (UV)-detection at 286 nm. The standard curves in urine were linear ranging from 0.5 to 100.0 microg/ml for each enantiomer. The mean extraction efficiency was >88.0%. Precision of the assay was <15% (CV) and was within 12% at the limit of quantitation (0.5 microg/ml). Bias of the assay was <15% and was within 6% at the limit of quantitation. The assay was applied successfully to stereospecific disposition of isosakuranetin enantiomers in rat urine.  相似文献   

17.
A procedure for the high-performance liquid chromatographic determination of tobramycin in serum is described using pre-column derivatisation with 1-fluoro-2,4-dinitrobenzene and subsequent chromatographic analysis on a reversed-phase column with ultraviolet detection. Gentamicin is used as the internal standard. The sensitivity is 0.5 mg/l with 50-μl samples. Precision, expressed as the coefficient of variation, is 3% or better in the concentration range 0.5–16 mg/l. The absolute recovery of tobramycin is 41%.The analyses of serum samples obtained in an in vivo experiment correlated well with the results from a microbiological assay. The influence of variation of derivatisation conditions and the implications for the reliability of the internal standardisation were studied. The 2,4-dinitrophenyl tobramycin derivative was synthesized and its structure was proved to be the fully derivatized tobramycin. Side-products of the derivatisation reaction were isolated.  相似文献   

18.
In order to measure changes in physiological CO concentrations in blood with good accuracy, a method was developed using gas chromatography with flame ionisation detection (250 degrees C). A nickel catalyst system was fitted to convert CO to methane at 375 degrees C after separation with a molecular sieve column at 35 degrees C. Helium was used as carrier at 30 ml/min. Porcine or human blood (400 microl) was sampled in gastight tubes and treated with sulfuric acid and saponin (800 microl). Accuracy was 1.4% and 1.5% (RSD), respectively. Precision was 2.8% (porcine blood). Limit of detection was 0.01 nmol/ml gas and limit of quantification 12 nmol/ml blood. Calibration was made in the interval 12-514 nmol/ml blood (corresponding to 0.1-6% COHb). Samples were stable for at least a month at +4 degrees C. This paper describes a method with high sensitivity and good accuracy, suitable for analysis of low CO concentrations.  相似文献   

19.
A simple and sensitive high-performance liquid chromatographic method has been developed to measure megazol in human plasma. The method was optimized and validated according to the Washington Concensus Conference on the Validation of Analytical Methods (V.P. Shah et al., Eur. J. Drug Metab. Pharmacokinet., 15 (1991) 249). The criteria of complete validation were specificity, linearity, precision, analytical recovery, dilution and stability. It involved extraction of the plasma with dichloromethane, followed by reversed-phase high-performance liquid chromatography using a KromasilR C8 column and UV detection at 360 nm. The retention times of the internal standard (tinidazol) and megazol were 6.10 and 9.60 min, respevtively. The standard curve was linear from 2 ng ml−1 (limit of quantification) to 2000 ng ml−1. The coefficients of variation for all the criteria of validation were less than 6%; 85 to 92% extraction efficiencies were obtained. Megazol was stable during the storage period (one month at −20°C) in plasma and for two months at 25°C in standard solution. The method was tested by measuring the plasma concentration following oral administration to rat and was shown to be suitable for pharmacokinetic studies.  相似文献   

20.
The use of reversed-phase high-performance liquid chromatography for the determination of the biologically active plant phenolic compounds mangiferin, likviritin and dihydroquercetin is described. Perchloric acid (35%) was used for deproteinization in the case of mangiferin and likviritin, and acidified methanol for dihydroquercetin. Detection was performed at 254, 275 and 290 nm for mangiferin, likviritin and dihydroquercetin in plasma, and 365, 312 and 290 nm in urine, respectively. The limit of detection was 0.2 μg/ml for plasma and 0.5 μg/ml for urine.  相似文献   