首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 30 毫秒
1.
A high-performance liquid chromatographic procedure was developed for the determination of caffeine in various biologic fluids and coffee. A reversed-phase column and UV detection at 254 nm were used to obtain a sensitivity of 0.1 μg/ml caffeine in serum and saliva using a sample volume of 0.1 ml. Caffeine metabolites and commonly ingested xanthines do not interfere with the assay. The within-day coefficients of variation were 9.8 and 9.9% at plasma caffeine concentrations of 2 and 10 μg/ml, respectively. The day-to-day coefficients of variation were 6.8 and 6.6% at plasma caffeine concentrations of 2 and 10 μg/ml, respectively. Serum and saliva caffeine concentrations were determined following a single oral dose of coffee and an intravenous infusion of caffeine in one subject. Computer estimates of caffeine pharmacokinetic parameters in one subject are in excellent agreement with previously published values.  相似文献   

2.
A rapid and sensitive capillary gas-chromatographic method with nitrogen-sensitive detection is reported for the simultaneous analysis of nicotine and cotinine levels occurring in the plasma, saliva, and urine of regular tobacco smokers. The proposed assay has a linear output, has satisfactory accuracy over the range of concentrations of both amines encountered in active smokers, and has also been successful in the analysis of the urine samples of passive smokers. Its lower limit of sensitivity is 0.2 ng of nicotine and 0.5 ng of cotinine per ml of plasma or saliva or per 100 l of urine.The beneficial characteristics of the presented method were achieved by the combination of solid phase extraction of 0.1–1.0 ml of fluid specimens, capillary column gas chromatography with splitless injection and nitrogen sensitive detection, and the use of separate, structurally analogous compounds as internal standards for nicotine. The suitability of the assay is shown by plasma concentration-time curves of nicotine and cotinine in a steady smoker during a 24 hours period.  相似文献   

3.
The paper describes a HPLC–fluorimetric procedure for the determination of methylenedioxyamphetamine, methylenedioxymethamphetamine, methylenedioxyethamphetamine and N-methyl-1-(1,3-benzodioxol-5-yl)-2-butanamine in urine, serum, saliva and street samples, that features interesting advantages over other procedures previously described. The method requires a very small sample volume (100 μl) and no extraction, lacks matrix effect, and is not time consuming. Linearity was in the range 50–1000 ng/ml regardless of matrix. Sensitivity and detection limit were 50 ng/ml and 10 ng/ml, respectively, but they may reach 10 ng/ml and 2 ng/ml if a slight modification is introduced in the procedure. Intra- and inter-day precision were always within 5% and 8%, respectively. Recovery was satisfactory for all matrices. The described procedure could be successfully used for clinical, epidemiological and forensic applications.  相似文献   

4.
This paper describes the development of a simple and sensitive analytical method for the quantification of melatonin in human plasma and rabbit serum, using standard analytical equipment and on-line column enrichment without prior extraction, clean-up or derivatization. The analytical procedure was found to be accurate, precise and linear. For human plasma, the accuracy was 101% (range 89–106%), and the mean precision was 5% (range 2–9%) for all concentrations (0, 2, 10, 50 and 200 ng/ml) tested (n=6). The accuracy in rabbit serum was 101% (range 90–112%), and the mean precision was 13% (range 8–19%) for all concentrations (0, 2, 10, 50, 200 and 500 ng/ml) tested (n=6). The retention time of melatonin was about 8 min and the total recoveries were found to be approximately 65 and 85%, respectively, for human plasma and rabbit serum. The limit of detection was found to be lower than 1 ng/ml for human plasma and around 2 ng/ml for rabbit serum. The method is, therefore, found to be suitable for melatonin bioavailability studies in rabbits and presumably also in humans.  相似文献   

5.
We have developed a simple, sensitive, specific and reproducible stereoselective high-performance liquid chromatography technique for analytical separation of cisapride enantiomers and measurement of cisapride enantiomers in human plasma. A chiral analytical column (ChiralCel OJ) was used with a mobile phase consisting of ethanol–hexane–diethylamine (35:64.5:0.5, v/v/v). This assay method was linear over a range of concentrations (5–125 ng/ml) of each enantiomer. The limit of quantification was 5 ng/ml in human plasma for both cisapride enantiomers, while the limit of detection was 1 ng/ml. Intra- and inter-day C.V.s did not exceed 15% for all concentrations except at 12.5 ng/ml for EII (+)-cisapride, which was 20 and 19%, respectively. The clinical utility of the method was demonstrated in a pharmacokinetic study of normal volunteers who received a 20 mg single oral dose of racemic cisapride. The preliminary pharmacokinetic data obtained using the method we describe here provide evidence for the first time that cisapride exhibits stereoselective disposition.  相似文献   

6.
A sensitive and specific high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of minocycline in human plasma and parotid saliva samples. Samples were extracted using an Oasis™ HLB cartridge and were injected into a C8 Nucleosil column. The HPLC eluent contained acetonitrile–methanol–distilled water–0.1% trifluoroacetic acid (25:2:72.9:0.1, v/v). Demeclocycline was used as internal standard. The assay showed linearity in the tested range of 0.1–25 μg/ml. The limit of quantitation was 100 ng/ml. Recovery from plasma or parotid saliva averaged 95%. Precision expressed as %CV was in the range 0.2–17% (limit of quantitation). Accuracy ranged from 93 to 111%. In the two matrices studied at 20 and 4°C, rapid degradation of the drug occurred. Frozen at −30°C, this drug was stable for at least 2 months, the percent recovery averaged 90%. The method’s ability to quantify minocycline with precision, accuracy and sensitivity makes it useful in pharmacokinetic studies.  相似文献   

7.
A high-performance liquid chromatographic (HPLC) procedure has been developed for the quantification of L-365,260 (I), a cholecystokinin and gastrin receptor antagonist, in dog and rat plasma. The method involves liquid—liquid extraction and HPLC with ultraviolet detection. Standard curves were linear over the range 7.5–2000 ng/ml for rat and dog plasma. The method is reproducible and reliable with a detection limit of 7.5 ng/ml in biological fluids. The mean coefficients of variation for concentrations within the range of the standard curve range were 3.84 and 2.56%, respectively, for intra-day analysis and 4.48 and 4.26%, respectively, for inter-day analysis. Application of the development was successfully demonstrated by quantifying the concentration of I in both dog and rat plasma samples following an intravenous or oral dose of 5 mg/kg I.  相似文献   

8.
A rapid and simplified chromatographic assay is reported for the quantification of adefovir (PMEA) utilizing derivatization with chloroacetaldehyde. Adefovir is isolated from plasma using protein precipitation with trichloroacetic acid; next, the fluorescent 1,N6-etheno derivative is directly formed at 98°C in the buffered extract with chloroacetaldehyde. This derivative is analyzed using isocratic ion-pair liquid chromatography and fluorescence detection at 254 nm for excitation and 425 nm for emission. In the evaluated concentration range (10–1000 ng/ml) precisions ≤5% and accuracies between 95 and 117% were found, using a 0.2-ml volume of plasma. The lower limit of quantification is 10 ng/ml with a intra-assay precision of 16%. The currently reported bioanalytical method is 20–25-fold more sensitive than previously published assays.  相似文献   

9.
A high-performance liquid chromatographic method has been developed for the determination of a new cephalosporin antibiotic in plasma, urine and saliva (mixed saliva) using normal-phase technique and an NH2 bonded-phase column. The eluent mixture was a combination of acetonitrile and an aqueous solution of ammonium carbonate. The rapid method involved precipitation of protein from fluids by means of acetonitrile followed by automatic injection of the supernatant. The detection limit was 0.4 μg/ml for plasma, 3 μg/ml for urine and 0.03 μg/ml for saliva using UV detection.  相似文献   

10.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid–liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1–5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83±6 and 92±6% in plasma, respectively, and 79±7 and 89±7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

11.
A validated high-performance liquid chromatographic procedure employing ultraviolet detection for the analysis of diclofenac in human plasma is reported. The method is rapid and, coupled with column switching, leads to a sensitive, accurate and reproducible assay. The retention times of diclofenac and the internal standard (4′-methoxydiclofenac, CGP-4287) are 6.4 and 7.6 min, respectively. The peak height versus plasma concentration is linear over the range 5.0–2000 ng/ml with a detection limit below 2.5 ng/ml. The mean absolute recovery of diclofenac using the described assay is 96.5% (n = 24). The inter- and intra-day accuracy and precision are within 8.3% of the actual values for all concentrations investigated. Furthermore, this procedure is applied to assess the pharmacokinetics of a single 75-mg oral dose of diclofenac sodium.  相似文献   

12.
A simple high-performance liquid chromatographic procedure was developed for the determination of ranitidine in human plasma. The method entailed direct injection of the plasma samples after deproteination using perchloric acid. The chromatographic separation was accomplished with an isocratic elution using mobile phase consisting of 21 mM disodium hydrogen phosphate–triethylamine-acetonitrile (1000:60:150, v/v), pH 3.5. Analyses were run at a flow-rate of 1.3 ml/min using a μbondapak C18 column and ultraviolet detection at a wavelength of 320 nm. The method was specific and sensitive, with a quantification limit of approximately 20 ng/ml and a detection limit of 5 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery was about 96%, while the within- and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The linearity was assessed in the range of 20–1000 ng/ml plasma, with a correlation coefficient of greater than 0.999. This method has been used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

13.
N-(n-Propyl)-N-(4-pyridinyl)-1H-indol-1-amine hydrochloride (HP 749, I), a non-receptor-dependent cholinomimetic agent with noradrenergic activity, is a potential agent for the treatment of Alzheimer's disease. Pharmacokinetic studies in animals and humans showed that I was well absorbed and metabolized primarily to the N-despropyl metabolite (P7480, II) after oral administration. To facilitate the kinetic studies, a sensitive and selective high-performance chromatographic assay was developed. I and II are extracted from plasma by a mixture of cyclohexane—ethyl acetate and chromatographed on an isocratic reversed-phase high-performance liquid chromatographic system employing an analytical phenyl column with acetonitrile—ammonium formate as mobile phase. The concentrations of these two compounds, quantitated by internal standardization, are monitored by ultraviolet detection. The method is linear in the plasma assay over a concentration range of 0.5–500 ng/ml for both compounds with a quantitation limit of 0.5 ng/ml. The precision and accuracy of the calibration curves and/or method are less than 10%. The recovery of I and II from plasma is 63–74 and 63–68%, respectively, over a concentration range of 0.5–500 ng/ml.  相似文献   

14.
A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 ml) was deproteinized by adding ethanol (1.5 ml) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate–acetic acid–ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate–acetic acid–ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile–methanol–ethanol–2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5–2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4–96.5% for retinol (range 100–1000 ng/ml) and 92.7–96.0% for retinyl palmitate (range 5–1000 ng/ml). Inter-assay precision was ≤5.1% and ≤6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels of retinol and retinyl esters determined in female volunteers were in good accordance with published data.  相似文献   

15.
A high-performance liquid chromatographic (HPLC) procedure has been developed for the quantification of Melanotan-II (MT-II), a cyclic heptapeptide which promotes rapid tanning of the skin, in rat plasma. The method involves precipitation of plasma proteins followed by direct-injection HPLC with ultraviolet detection. Calibration curves were linear over the range 100–1000 ng/ml for rat plasma. The method is reproducible and reliable with a detection limit of 50 ng/ml in plasma. Within- and between-day precision and accuracy reported as coefficient of variation and relative error, respectively, were < 7%. The application of the assay was successfully demonstrated by quantifying the concentration of MT-II in rat plasma samples following an intravenous dose of 0.3 mg/kg.  相似文献   

16.
A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCl. The maximum plasma concentrations were 235–465 ng/ml (MDE), 67–673 ng/ml (HME) and 7–33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves.  相似文献   

17.
A sensitive, stereoselective high-performance liquid chromatographic method with fluorescence detection for the measurement of bisoprolol enantiomers in human plasma and urine has been developed. Bisoprolol was extracted at alkaline pH with chloroform, followed by solid-phase extraction. The effluent was evaporated, and the reconstituted residue was chromatographed on a Chiralcel OD column with a mobile phase of hexane—2-propanol (10:0.9, v/v) containing 0.01% (v/v) diethylamine. Within the plasma and urine enantiomeric concentration ranges of 5–100 ng/ml and 25–1250 ng/ml, respectively, a linear relationship was obtained between the peak-height ratios and the corresponding concentrations. The limit of quantitation, defined as three times the baseline noise, was 2 ng/ml for each enantiomer in plasma. A preliminary pharmacokinetic study was undertaken in three healthy male volunteers following an oral dose of 5 mg of racemic bisoprolol. The results confirm that this assay is suitable for pharmacokinetic studies of bisoprolol enantiomers in humans following oral administration of the therapeutic dose.  相似文献   

18.
A new, simple, reproducible and reliable high-performance liquid chromatography method with ultraviolet absorbance detection at 240 nm was developed and validated for the determination of 7-oxo-dehydroepiandrosterone-3β-sulfate in human plasma. The method was based upon solid-phase (C18) extraction of plasma after addition of 17β-hydroxy-3β-methoxyandrost-5-en-7-one as internal standard. Using 1 ml of plasma for extraction, the detection limit of the assay was 3 ng/ml. The standard curve was linear over the concentration range 10–1000 ng/ml. Stored at −20°C for about 4 months at various concentrations in plasma, 7-oxo-dehydroepiandrosterone-3β-sulfate did not reveal any appreciable degradation. Also included herein is a method for the simultaneous detection and determination of 7-oxo-dehydroepiandrosterone and 7-oxo-dehydroepiandrosterone-3β-acetate in plasma.  相似文献   

19.
The first method using high-performance liquid chromatography (HPLC) has been developed for the determination of trans-resveratrol in human plasma. The method involves a liquid–liquid extraction followed by reversed-phase HPLC with UV detection. The detection limit of trans-resveratrol in human plasma was 5.0 ng/ml. Standard curves are linear over the concentration range of 5.0–5000.0 ng/ml. Intra-assay variability ranged from 1.9 to 3.7% and inter-assay variability ranged from 2.5 to 4.0% at the concentration range of 15.0–4000.0 ng/ml.  相似文献   

20.
A selective and sensitive high-performance liquid chromatographic assay with ultraviolet detection for the determination of the antidepressant drug etoperidone and two active metabolites in plasma is described. The drug, metabolites and internal standard are isolated from plasma using a two-step liquid—liquid extraction procedure. The resulting sample is chromatographed on a C18 column (10 cm × 2.1 mm I.D.) with ultraviolet detection at 254 nm. Standard curves are linear for each compound over the concentration range 2–1000 ng/ml. The accuracy and precision of the assay, expressed as the percentage deviation of measured values from the true value and the relative standard deviation (inter-run), are ≤ 10% at all concentrations except the minimum quantification limit. Using an automated injector and computerized data acquisition, eighty samples can be routinely processed in one day. The assay has been successfully used for the analysis of plasma samples from pharmacokinetic studies in mice, rats, dogs and humans.  相似文献   