首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The use of Inertial Measurement Units (IMUs) for spatial gait analysis has opened the door to unconstrained measurements within the home and community. Bandwidth, cost limitations, and ease of use has historically restricted the number and location of sensors worn on the body. In this paper, we describe a four-sensor configuration of IMUs placed on the shanks and thighs that is sufficient to provide an accurate measure of temporal gait parameters, spatial gait parameters, and joint angle dynamics during ambulation. Estimating spatial gait parameters solely from gyroscope data is preferred because gyroscopes are less susceptible to sensor noise and a system comprised of only gyroscopes uses decreased bandwidth compared to a typical 9 degree-of-freedom IMU. The purpose of this study was to determine the validity of a novel method of step length estimation using gyroscopes attached to the shanks and thighs. An Inverted Pendulum Model algorithm (IPM) was proposed to calculate step length, stride length, and gait speed. The algorithm incorporates heel-strike events and average forward velocity per step to make these assessments. IMU algorithm accuracy was determined via concurrent validity with an instrumented walkway and results explained via the collision model of gait. The IPM produced accurate estimates of step length, stride length, and gait speed with a mean difference of 3 cm and an RMSE of 6.6 cm for step length, thus establishing a new approach for spatial gait parameter calculation. The lack of numerical integration in IPM makes it well suited for use in continuous monitoring applications where sensor sampling rates are restricted.  相似文献   

2.
This study compares the performance of algorithms for body-worn sensors used with a spatiotemporal gait analysis platform to the GAITRite electronic walkway. The mean error in detection time (true error) for heel strike and toe-off was 33.9 ± 10.4 ms and 3.8 ± 28.7 ms, respectively. The ICC for temporal parameters step, stride, swing and stance time was found to be greater than 0.84, indicating good agreement. Similarly, for spatial gait parameters--stride length and velocity--the ICC was found to be greater than 0.88. Results show good to excellent concurrent validity in spatiotemporal gait parameters, at three different walking speeds (best agreement observed at normal walking speed). The reported algorithms for body-worn sensors are comparable to the GAITRite electronic walkway for measurement of spatiotemporal gait parameters in healthy subjects.  相似文献   

3.
The duration of stance and swing phase and step and stride length are important parameters in human gait. In this technical note a low-cost ultrasonic motion analysis system is described that is capable of measuring these temporal and spatial parameters while subjects walk on the floor. By using the propagation delay of sound when transmitted in air, this system is able to record the position of the subjects' feet. A small ultrasonic receiver is attached to both shoes of the subject while a transmitter is placed stationary on the floor. Four healthy subjects were used to test the device. Subtracting positions of the foot with zero velocity yielded step and stride length. The duration of stance and swing phase was calculated from heel-strike and toe-off. Comparison with data obtained from foot contact switches showed that applying two relative thresholds to the speed graph of the foot could reliably generate heel-strike and toe-off. Although the device is tested on healthy subjects in this study, it promises to be extremely valuable in examining pathological gait. When gait is asymmetrical, walking speed is not constant or when patients do not completely lift their feet, most existing devices will fail to correctly assess the proper gait parameters. Our device does not have this shortcoming and it will accurately demonstrate asymmetries and variations in the patient's gait. As an example, the recording of a left hemiplegic patient is presented in the discussion.  相似文献   

4.
The use of inertial measurement units (IMUs) for gait analysis has emerged as a tool for clinical applications. Shank gyroscope signals have been utilized to identify heel-strike and toe-off, which serve as the foundation for calculating temporal parameters of gait such as single and double limb support time. Recent publications have shown that toe-off occurs later than predicted by the dual minima method (DMM), which has been adopted as an IMU-based gait event detection algorithm. In this study, a real-time algorithm, Noise-Zero Crossing (NZC), was developed to accurately compute temporal gait parameters. Our objective was to determine the concurrent validity of temporal gait parameters derived from the NZC algorithm against parameters measured by an instrumented walkway. The accuracy and precision of temporal gait parameters derived using NZC were compared to those derived using the DMM. The results from Bland-Altman Analysis showed that the NZC algorithm had excellent agreement with the instrumented walkway for identifying the temporal gait parameters of Gait Cycle Time (GCT), Single Limb Support (SLS) time, and Double Limb Support (DLS) time. By utilizing the moment of zero shank angular velocity to identify toe-off, the NZC algorithm performed better than the DMM algorithm in measuring SLS and DLS times. Utilizing the NZC algorithm’s gait event detection preserves DLS time, which has significant clinical implications for pathologic gait assessment.  相似文献   

5.
E Sejdić  Y Fu  A Pak  JA Fairley  T Chau 《PloS one》2012,7(8):e43104
Walking is a complex, rhythmic task performed by the locomotor system. However, natural gait rhythms can be influenced by metronomic auditory stimuli, a phenomenon of particular interest in neurological rehabilitation. In this paper, we examined the effects of aural, visual and tactile rhythmic cues on the temporal dynamics associated with human gait. Data were collected from fifteen healthy adults in two sessions. Each session consisted of five 15-minute trials. In the first trial of each session, participants walked at their preferred walking speed. In subsequent trials, participants were asked to walk to a metronomic beat, provided through visually, aurally, tactile or all three cues (simultaneously and in sync), the pace of which was set to the preferred walking speed of the first trial. Using the collected data, we extracted several parameters including: gait speed, mean stride interval, stride interval variability, scaling exponent and maximum Lyapunov exponent. The extracted parameters showed that rhythmic sensory cues affect the temporal dynamics of human gait. The auditory rhythmic cue had the greatest influence on the gait parameters, while the visual cue had no statistically significant effect on the scaling exponent. These results demonstrate that visual rhythmic cues could be considered as an alternative cueing modality in rehabilitation without concern of adversely altering the statistical persistence of walking.  相似文献   

6.
7.
The Timed Up & Go test (TUG) is functional test and is a part of routine clinical examinations. The instrumented Timed Up & Go test enables its segmentation to sub-tasks: sit-to-stand, walking forward, turning, walking back, stand-to-sit, and consequently the computation of task-specific parameters and sub-tasks separately. However, there are no data on whether walking forward parameters differ from the walking back parameters. This study tested the differences between walking forward and walking back in the TUG extended to 10 m for 17 spatio-temporal gait parameters. All parameters were obtained from a GAITRite® pressure sensitive walkway (CIR Systems, Inc.). The differences were assessed for healthy controls and Parkinson's disease (PD) patients. None of investigated parameters exhibited a difference between both gait subtasks for healthy subjects group. Five parameters of interest, namely velocity, step length, stride length, stride velocity, and the proportion of the double support phase with respect to gait cycle duration, showed a statistically significant difference between gait for walking forward and walking back in PD patients. Therefore, we recommend a separate assessment for walking forward and walking back rather than averaging both gaits together.  相似文献   

8.
Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect’s 3D body point’s time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point’s time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point’s time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters’ walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman’s bias and limits of agreement. Body point’s time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point’s time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner.  相似文献   

9.
In this study we describe an ambulatory system for estimation of spatio-temporal parameters during long periods of walking. This original method based on wavelet analysis is proposed to compute the values of temporal gait parameters from the angular velocity of lower limbs. Based on a mechanical model, the medio-lateral rotation of the lower limbs during stance and swing, the stride length and velocity are estimated by integration of the angular velocity. Measurement's accuracy was assessed using as a criterion standard the information provided by foot pressure sensors. To assess the accuracy of the method on a broad range of performance for each gait parameter, we gathered data from young and elderly subjects. No significant error was observed for toe-off detection, while a slight systematic delay (10 ms on average) existed between heelstrike obtained from gyroscopes and footswitch. There was no significant difference between actual spatial parameters (stride length and velocity) and their estimated values. Errors for velocity and stride length estimations were 0.06 m/s and 0.07 m, respectively. This system is light, portable, inexpensive and does not provoke any discomfort to subjects. It can be carried for long periods of time, thus providing new longitudinal information such as stride-to-stride variability of gait. Several clinical applications can be proposed such as outcome evaluation after total knee or hip replacement, external prosthesis adjustment for amputees, monitoring of rehabilitation progress, gait analysis in neurological diseases, and fall risk estimation in elderly.  相似文献   

10.
The instantaneous velocity of the forward-going foot is measured throughout the swing phase during several successive gait cycles using punched paper tapes attached to the feet. The velocity profiles thus obtained show clearly any asymmetry or departure from the normal walking pattern. The data are processed to provide the spatial and temporal parameters of gait, i.e. step lengths, stride times, double-support times, cadence and walking speed. The equipment is low-cost, easy to set up and use, and the results, which are presented on the VDU or as hard copy, are readily interpreted and related to the underlying pathology.  相似文献   

11.
The purpose of this study was to determine the effect (if any) of significant sensory loss on the long-range correlations normally observed in the stride intervals of human gait. Fourteen patients with severe peripheral neuropathy and 12 gender-, age-, height-, and weight-matched nondiabetic controls participated. Subjects walked around an approximately 200-m open-level walkway for 10 min at their comfortable pace. Continuous knee joint kinematics were recorded and used to calculate a stride interval time series for each subject. Power spectral density and detrended fluctuation analyses were used to determine whether these stride intervals exhibited long-range correlations. If the loss of long-range correlations indicates deterioration of the central control of gait, then changes in peripheral sensation should have no effect. If instead the loss of long-range correlations is a consequence of a general inability to regulate gait cycle timing, then a similar loss should occur in patients with peripheral locomotor disorders. Both power spectral density analyses and detrended fluctuation analyses showed that temporal correlations in the stride times of neuropathic and control subjects were statistically identical (P = 0.954 and P = 0.974, respectively), despite slower gait speeds (P = 0.008) and increased stride time variability (P = 0.036) among the neuropathy patients. All subjects in both groups exhibited long-range correlations. These findings demonstrate that the normal long-range correlation structure of stride intervals is unaltered by significant peripheral sensory loss. This further supports the hypothesis that the central nervous system is involved in the regulation of long-range correlations.  相似文献   

12.
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6 MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8 cm for stride length, 1.4±5.6 cm/s for stride velocity, 1.9±2.0 cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6 MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.  相似文献   

13.
Modern three-dimensional gait analysis systems give information on joint angles and moments in the sagittal and coronal planes, for which normal ranges may not be readily available in the literature. Since patients with joint disease tend to walk slowly and with a short stride, it is essential that normal ranges for gait parameters should be defined with reference to speed of walking. This we have done using a population of 10 normal male subjects agea from 18 to 63 years, walking at speeds which range from very slow to very fast. The ranges of knee angle and moment are given, together with the changes in these parameters with walking speed. Peak knee flexion moment is strongly related to walking speed, whereas coronal plane knee angle is virtually independent of it. The stride length is probably the best basis for deciding the normal range for a particular measurement.  相似文献   

14.
Head-bobbing walking (HBW) and non-bobbing walking (NBW) of black-headed gulls were compared from kinematic and behavioral/environmental viewpoints. The birds walked with a longer stride length and lower stride frequency during the HBW than during the NBW. With respect to these two parameters, the HBW of black-headed gulls was similar to that of other head-bobbers, and the NBW was similar to that of other non-bobbers. The stride length and the amplitude of head bobbing were correlated. These results suggest that the head-bobbing and gait parameters are related. From a behavioral viewpoint, HBW was observed during seeking-type foraging by wading, and NBW was observed during waiting-type foraging on a flat substrate. The type of foraging behavior and/or substrate condition probably determines whether the birds walk with or without head bobbing.  相似文献   

15.

Objective

The control of gait requires executive and attentional functions. As preterm children show executive and attentional deficits compared to full-term children, performing concurrent tasks that impose additional cognitive load may lead to poorer walking performance in preterm compared to full-term children. Knowledge regarding gait in preterm children after early childhood is scarce. We examined straight walking and if it is more affected in very preterm than in full-term children in dual-task paradigms.

Study design

Twenty preterm children with very low birth-weight (≤ 1500 g), 24 preterm children with birth-weight > 1500 g, and 44 full-term children, born between 2001 and 2006, were investigated. Gait was assessed using an electronic walkway system (GAITRite) while walking without a concurrent task (single-task) and while performing one concurrent (dual-task) or two concurrent (triple-task) tasks. Spatio-temporal gait parameters (gait velocity, cadence, stride length, single support time, double support time), normalized gait parameters (normalized velocity, normalized cadence, normalized stride length) and gait variability parameters (stride velocity variability, stride length variability) were analyzed.

Results

In dual- and triple-task conditions children showed decreased gait velocity, cadence, stride length, as well as increased single support time, double support time and gait variability compared to single-task walking. Further, results showed systematic decreases in stride velocity variability from preterm children with very low birth weight (≤ 1500 g) to preterm children with birth weight > 1500 g to full-term children. There were no significant interactions between walking conditions and prematurity status.

Conclusions

Dual and triple tasking affects gait of preterm and full-term children, confirming previous results that walking requires executive and attentional functions. Birth-weight dependent systematic changes in stride velocity variability indicate poorer walking performance in preterm children who were less mature at birth.  相似文献   

16.

Background

Gait performance is widely evaluated to assess health status in older adult populations. While several investigators have presented normative values for spatiotemporal gait parameters drawn from older adult populations, the literature has been void of large-scale cohort studies, which are needed in order to provide quantitative, normative gait data in persons with Parkinson’s disease. The aim of this investigation was to provide reference values for clinically important gait characteristics in a large sample of ambulatory persons with Parkinson’s disease to aid both clinicians and researchers in their evaluations and treatments of gait impairment.

Methodology/Principal Findings

Gait performance was collected in 310 individuals with idiopathic Parkinson’s disease as they walked across a pressure sensitive walkway. Fourteen quantitative gait parameters were measured and evaluated with respect to Hoehn and Yahr disease staging and gender. Disease duration and age were controlled for in all analyses. Individuals with the greatest Parkinson’s disability walked significantly slower with shorter steps and stride lengths than the mild and moderately affected groups. Further, the most affected patients spent more time with both feet on the ground, and walked with a wider base of support than the moderately disabled patients. No differences were detected between the mild and moderate disability groups on any of the gait parameters evaluated.

Conclusions/Significance

Reference values for 14 gait parameters in a large cohort of ambulatory patients with Parkinson’s disease are provided and these may be highly useful for assessing and interpreting an individual’s gait dysfunction. It is important for clinicians and researchers to appreciate the lack of change in quantitative parameters as PD patients move from mild to moderate gait impairment.  相似文献   

17.
This study investigated the lower extremity torque's active and passive features during the walk-to-run gait transition with continuously increased walking speed. Fourteen volunteers participated in the experiment. Kinematic and kinetic data were collected synchronously. Five strides leading up the gait transition were examined. Peaks of the passive (e.g., contact) and active (e.g., generalized muscle torques), along with net joint torque, and time to peak torques exhibited significant differences at the last stride before gait transition, compared to the first four strides, at the ankle, knee, and hip joints, respectively. Selected peak joint active and passive torques showed significant and opposite trends at critical events within a stride cycle: such ankle joint right after heel-contact, knee joint during weight acceptance, and both hip and knee joints right before toe-off. The magnitude and the corresponding time to active and passive peak torque changed in a nonlinear pattern before the transition from walk to run. The lower extremity segment-interaction during gait transition appeared to be an active reorganization exemplified by the interaction between the lower extremity's active and passive torque components.  相似文献   

18.
Gait dynamics on an inclined walkway   总被引:1,自引:0,他引:1  
OBJECTIVE: This paper documents research that quantifies and describes the biomechanics of normal gait on inclined surfaces. DESIGN: Experimental, investigative. BACKGROUND: It is necessary to walk on inclined surfaces to negotiate the natural and built environments. Little research has been conducted on the biomechanics of normal gait on inclined surfaces. METHODS: The gait of 11 healthy male volunteers was measured using a Vicon system 370 on an inclinable walkway. Gait was measured at 0 degrees , 5 degrees , 8 degrees and 10 degrees of incline. Passive optical markers were placed on each subject and they walked at a self-selected speed up and down the walkway. Ground reaction forces and EMG were measured. Gait data were analysed in Vicon Clinical Manager. RESULTS: Changes in the dynamics of the lower limbs with respect to incline angles are described. Between subject and between condition differences in biomechanical parameters were significant. Hip flexion increased at heel strike with inclines from -10 degrees to +10 degrees . Knee flexion and ankle dorsiflexion at heel strike increased with increasing angle walking up, but not down. Changes in joint moments and powers due to change in the angle of incline or direction of walking were observed. CONCLUSIONS: The mechanisms by which the body enables walking up and downhill, specifically raising and lowering the centre of mass, and preventing slipping, can be seen in the alteration in the dynamics of the lower limbs. Increases in range of motion and muscle strength requirements need to be considered in the design of lower limb prostheses and in orthopaedic and neurological rehabilitation. RELEVANCE: Gait, prosthetics, rehabilitation, balance and falls.  相似文献   

19.
The kinematic gait characteristics of six species of birds in three groups were compared. The groups studied were herons (Gray Herons and Little Egrets), ground-feeders (Domestic Pigeons and Gray Starlings), and waterfowl (Pintails and Black-headed Gulls). The results showed that the relative stride frequency was greater in the waterfowl than in the other species. Complementary to this, the amplitude of the movements was smaller in the waterfowl than in the others. These differences between the waterfowl and the other species might be caused by their morphological and/or physiological adaptation to swimming. Another possible cause for these differences was the magnitude of head bobbing, as the ground-feeders and herons, which walk with head bobbing, showed a large relative stride length and excursion angle, while the waterfowl, which do not head-bob, walk with a relatively short stride length and small excursion angle. Moreover, the relative magnitude of head movement during walking was especially large in Little Egrets, which showed an especially large relative stride length and excursion angle. These parameters may have some mechanical relationships with each other.  相似文献   

20.
Gibbons are highly arboreal apes, and it is expected that their bipedal locomotion will show some particularities related to the arboreal environment. Previous research has shown that, during hylobatid bipedalism, unsupported phases are rare and stride frequencies are relatively low. This study confirms previous findings, and we suggest that low stride frequencies and the absence of unsupported phases are ways to reduce disadvantageous branch oscillations during arboreal travel. Despite these restrictions, gibbons are able to locomote at a wide range of speeds, implying that they likely exploit other mechanisms to modulate their locomotor speed. To investigate this possibility, we collected video images of a large number of spontaneous bipedal bouts of four untrained white-handed gibbons by using an instrumented walkway with four synchronized cameras. These video images were digitized to obtain a quantification of the 3D kinematics of hylobatid bipedalism. We defined a large number of spatiotemporal and kinematic gait variables, and the relationship between these gait variables and (dimensionless) speed was statistically tested. It was found that gibbons mainly increase stride length to increase their locomotor speed; the main speed-modulating mechanisms are hip and ankle excursion and coupled knee and ankle extension at toe-off. Although aerial phases are rare, gibbons generally adopt a bipedal bouncing gait at most speeds and a clear-cut gait transition, as seen in human locomotion, is absent. Comparison with human and bonobo bipedalism showed that the variability of the 3D joint angles of the hind limb are comparable during human and gibbon bipedalism, and much lower than during bonobo bipedalism. The low variability found in gibbons might be related to constraints imposed by the arboreal environment. These arboreal constraints clearly affect the bipedal gait characteristics of gibbons, but do not constrain the ability to adopt a bipedal bouncing gait during terrestrial locomotion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号