首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Quantification of α- and γ-endorphins in rat brain using liquid chromatography-electrospray ionization-tandem mass spectrometry is described. [D-Ala2]-γ-endorphin is used as an internal standard. The precursor-to-product ion MRM transitions for α-endorphin, γ-endorphin, and [D-Ala2]-γ-endorphin were m/z 873.6 → 429.6; 929.6 → 542.3; 936.6 → 542.3, respectively. The method was validated in terms of linearity, specificity, sensitivity, recovery, precision, and accuracy. The assay was linear over a concentration range of 0.1-200 ng/mL with the limit-of-detection of 0.03 ng/mL and limit-of-quantification of 0.1 ng/mL. The endogenous concentrations of α- and γ-endorphins in rat brains were 13.8 ± 0.57 (mean ± SD; n = 5) and 2.5 ± 0.43 ng/g of wet tissue weight, respectively.  相似文献   

2.
Electrospray tandem mass spectrometry was applied to detect a series of inherited metabolic disorders during a newborn-screening pilot study and a selective screening in Japan. In our mass screening of 102,200 newborns, five patients with propionic acidemia, two with methylmalonic acidemia, two with medium-chain acyl-CoA dehydrogenase deficiency, three with citrullinemia type II, and one with phenylketonuria were identified. In a selective screening of 164 patients with symptoms mainly related to hypoglycemia and/or hyperammonemia, 12 with fatty acid oxidation disorders and six with other disorders were found. The results indicated the importance of newborn screening using this technology in Japan.  相似文献   

3.
Dialkylphosphates (DAP) are urinary markers of the exposure to organophosphates pesticides. The aim of this study was to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantitative determination of the following DAP: dimethylphosphate (DMP), dimethythiophosphate (DMTP), dimethyldithiophosphate (DMDTP), diethylphosphate (DEP), diethylthiophosphate (DETP) and diethyldithiophosphate (DEDTP). Dibutylphosphate (DBP) was used as internal standard. This method was based on a liquid-liquid extraction procedure, a chromatographic separation using an Inertsil ODS3 C18 column and mass spectrometric detection in the negative ion, multiple reaction monitoring (MRM) mode, following two ion transitions per compound. It yielded a limit of quantification of 2 microg/L for the six compounds and intra-assay coefficients of variation (CV%) lower than 20%. This method was applied to the analysis of urines samples from a small cohort of non-exposed volunteers. At least one of the six DAP was detected in each sample. This result confirmed the feasibility of a LC-MS/MS procedure for monitoring the general population exposure to some frequently employed organophosphate pesticides.  相似文献   

4.
The objective of this study was to develop a very sensitive and selective method for the determination of scopolamine in serum with a rapid and simple sample preparation. A capillary column gas chromatographic-ion trap tandem mass spectrometric technique has been applied. Scopolamine and the internal standard mexiletine were extracted from serum samples and cleaned up by using a single step liquid-liquid extraction. Derivatization was carried out using 2,2,2-trifluoro-N-methyl-N-trimethylsilylacetamide. The mass spectrometer was operated with positive ions in the selected reaction mode with chemical ionisation using methane. The sum of peak height of two daughter ions was used for quantification. The detection limit was 50 pg/ml in serum.  相似文献   

5.
6.
This work aims to combine chromatographic retention, high mass resolution and accuracy, MS/MS spectra, and a package for automated identification and quantitation of lipid species in one platform for lipidomic analysis. The instrumental setup elaborated comprises reversed-phase HPLC coupled to a Fourier transform ion cyclotron resonance mass spectrometer (LTQ-FT), and Lipid Data Analyzer (LDA) software. Data analysis for lipid species quantification in this platform is based on retention time, mass resolution of 200,000, and mass accuracy below 2 ppm. In addition, automatically generated MS/MS spectra provide structural information at molecular level. This LC/MS technology allows analyzing complex biological samples in a quantitative manner as shown here paradigmatically for murine lipid droplets having a huge surplus of triacylglycerol species. Chromatographic preseparation of the bulk lipid class alleviates the problem of ion suppression of lipid species from other classes. Extension of 1D to 2D chromatography is possible, yet time consuming. The platform affords unambiguous detection of lipid species as low as 0.1‰ within major lipid classes. Taken together, a novel lipidomic LC/MS platform based on chromatographic retention, high mass resolution and accuracy, MS/MS analysis, and quantitation software enables analysis of complex samples as demonstrated for lipid droplets.  相似文献   

7.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of metolazone in human blood. Metolazone was extracted from blood using ethyl acetate and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of acetonitrile, 10 mmol/l ammonium acetate and formic acid (60:40:0.1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Electrospray ionization (ESI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 366-->m/z 259 and m/z 321-->m/z 275 were used to quantify metolazone and the lorazepam (internal standard), respectively. The linearity was obtained over the concentration range of 0.5-500 ng/ml for metolazone and the lower limit of quantitation (LLOQ) was 0.5 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 8.07 and 3.56% (relative standard deviation (RSD)), respectively, and the bias was within +/-4.0%. This method was successfully applied to the pharmacokinetic study of metolazone formulation after oral administration to humans.  相似文献   

8.
Carbofuran (CFN), carbosulfan (CSN) and fenobucarb (FBC) are carbamate pesticides that are widely used in gardening and agriculture for the control of insects. Human poisoning due to occupational or self-poisoning exposures is also reported, so assays are required to quantify the plasma concentration of these insecticides. An LC-MS/MS method was developed and validated for the simultaneous quantification of these three carbamate insecticides in the plasma of patients with acute intentional self-poisoning. Plasma samples were pretreated by acetonitrile for protein precipitation. Chromatography was carried out on a Luna C18(2) analytical column with gradient elution using a mobile phase containing acetonitrile and water with 10mM ammonium acetate. Mass spectrometric analysis was performed by an Applied Biosystems MDS Sciex API 2000 triple quadrupole mass spectrometer coupled with electrospray ionization (ESI) source in the positive ion mode. The total run time was 7 min. The assay was validated over a concentration range from 10 to 1000 ng/ml for CSN and FBC and 20-2000 ng/ml for CFN. The precision and accuracy for both intra- and inter-day determination of all analytes were acceptable (<15%). No significant matrix effect was observed. Stability of compounds was established for short term bench and autosampler storage as well as freeze/thaw cycles. The method was effectively applied to 270 clinical samples from patients with a history of acute intentional carbamate self-poisoning.  相似文献   

9.
Previous studies have shown that plasma 1,5-anhydroglucitol (1,5-AG) is markedly reduced among diabetic patients and therefore serves as a sensitive marker for short-term glycemic control. The current study describes the development of the liquid chromatography negative ion electrospray tandem mass spectrometry (LC-MS/MS) method to measure 1,5-AG in human plasma. The samples were pre-treated with protein precipitation and an isotope-labeled internal standard was used. Chromatographic separation was achieved on amide column (150 mm x 2.0mm i.d., 5 microm) followed by detection with multiple reaction monitoring mode. Linearity, accuracy, precision, recovery, matrix effect, and stability were evaluated during method validation over the range of 1-50 microg/mL. The validated method has been clinically applied among 159 type 2 diabetic patients and 290 control subjects. A marked reduction in 1,5-AG levels among the diabetic patients and significant between-gender difference in nondiabetic subjects were observed.  相似文献   

10.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of piroxicam, meloxicam and tenoxicam in human plasma was developed. Piroxicam, meloxicam, tenoxicam and isoxicam (internal standard) were extracted from human plasma with ethyl acetate at acidic pH and analyzed on a Sunfire column with the mobile phase of methanol:ammonium formate (15 mM, pH 3.0) (60:40, v/v). The analytes were detected using a mass spectrometer, equipped with electrospray ion source. The instrument was set in the multiple-reaction-monitoring (MRM) mode. The standard curve was linear (r=1.000) over the concentration range of 0.50-200 ng/ml. The coefficient of variation (CV) and relative error (RE) for intra- and inter-assay statistics at three QC levels were 1.0-5.4% and -5.9 to 2.8%, respectively. The recoveries of piroxicam, meloxicam and tenoxicam ranged from 78.3 to 87.1%, with that of isoxicam being 59.7%. The lower limit of quantification for piroxicam, meloxicam and tenoxicam was 0.50 ng/ml using a 100 microl plasma sample. This method was successfully applied to a pharmacokinetic study of piroxicam after application of transdermal piroxicam patches to humans.  相似文献   

11.
Changes in the glycosylation of some serum proteins are associated with certain diseases. In this study, we performed simultaneous site-specific glycosylation analysis of abundant serum glycoproteins by LC/Qq-TOF MS of human serum tryptic digest, the albumin of which was depleted. The glycopeptide peaks on the chromatogram were basically assigned by database searching with modified peak-list text files of MS/MS spectra and then based on mass differences of glycan units from characterized glycopeptides. Glycopeptide of IgG, haptoglobin and ceruloplasmin were confirmed by means of a comparison of their retention times and m/z values with those obtained by LC/MS of commercially available glycoproteins. Mass spectrometric carbohydrate heterogeneity in the assigned glycopeptides was analyzed by an additional LC/MS. We successfully demonstrated site-specific glycosylation of 23 sites in abundant serum glycoproteins.  相似文献   

12.
Chlorpyrifos and cypermethrin are the most used insecticides in Taiwan. Exposure to both pesticides has been associated with reproductive and developmental health effects in humans and animals. This study describes an online solid-phase extraction coupled with liquid chromatography-heated electrospray ionization tandem mass spectrometry (online SPE-LC/HESI/MS/MS) method to analyze chlorpyrifos and cypermethrin in cord blood of pregnant women. Calibration curves showed good linearity (r2 > 0.998) for both pesticides within the range of 0.1-100 ppb. Limits of detection (LODs) were 0.01 and 0.05 ppb and recoveries in cord blood were 97.2 ± 4.8% and 93.5 ± 9.5% for chlorpyrifos and cypermethrin respectively. After analysis of 396 samples, the mean concentrations of chlorpyrifos and cypermethrin were 0.38 and 1.08 ppb respectively. These results demonstrate that LC/HESI/MS/MS is effective for the simultaneous analysis of chlorpyrifos and cypermethrin in cord blood with excellent sensitivity and specificity and may also be effective for high throughput assay in future epidemiology studies.  相似文献   

13.
Each biocatalyst screen is unique, defined by the combination of factors involved in the screen, including the number and type of biocatalysts in the screening collection, substrate chemistry and the type of assay. Advances in the technology surrounding mass spectrometry — in software, in ionization sources and interfaces and in engineering, which allows smaller mass spectrometry systems and narrow bore HPLC — have made the application of this versatile technology in screening assays possible. A mass spectrometric assay provides sensitive, specific, quantitative, high-throughput detection of new biocatalyst activities. Examples of these applications are presented and potential pitfalls are discussed.  相似文献   

14.
This paper describes two high-throughput liquid chromatography-tandem mass spectrometry (LC-MS-MS) methods for the screening of two important classes of drugs in equine sports, namely corticosteroids and basic drugs, at low ppb levels in horse urine. The method utilized a high efficiency reversed-phase LC column (3.3 cm L x 2.1 mm i.d. with 3 microm particles) to provide fast turnaround times. The overall turnaround time for the corticosteroid screen was 5 min and that for the basic drug screen was 8 min, inclusive of post-run and equilibration times. Method specificity was assessed by analysing a total of 35 negative post-race horse urine samples. No interference from the matrices at the expected retention times of the targeted masses was observed. Inter-day precision for the screening of 19 corticosteroids and 48 basic drugs were evaluated by replicate analyses (n = 10) of a spiked sample on 4 consecutive days. The results demonstrated that both methods have acceptable precision to be used on a routine basis. The performance of these two methods on real samples was demonstrated by their applications to drug administration and positive post-race urine samples.  相似文献   

15.
For the first time, a liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the simultaneous determination of ribavirin and rabavirin base was developed and validated over the concentration range of 10-5,000 ng/ml, respectively, using a 0.025 ml monkey plasma sample. Ribavirin, ribavirin base, and the internal standards were extracted from monkey plasma via protein precipitation. After evaporation of the supernatant, the extract was reconstituted with 5% methanol (containing 0.1% formic acid) and injected onto the LC-MS/MS system. Optimum chromatographic separation was achieved on a Waters Atlantis dc18 (150 mm x 2.1mm, 5 microm) column with mobile phase run in gradient with 100% water containing 0.5% formic acid (A) and 90% acetonitrile (containing 0.5% formic acid (B). The flow rate was 0.4-0.6 ml/min with total cycle time of approximately 7.0 min. Post-column addition of acetonitrile (containing 0.1% formic acid) at 0.3 ml/min was used to increase the ionization efficiency in the MS source. The method was validated for sensitivity, linearity, reproducibility, stability and recovery. Lack of adverse matrix effect and carry-over was also demonstrated. The intra-day and inter-day precision and accuracy of the quality control (QC) samples were <9.0% relative standard deviation (R.S.D.) and 10.8% bias for ribavirin, and 10.3% R.S.D. and 11.3% bias for ribavirin base. The current specific, accurate and precise assay is useful in support of the toxicokinetic and pharmacokinetic studies of these compounds.  相似文献   

16.
We established a method for precisely determining residual tetracycline antibiotics (TCs) in foods by atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry (APCI LC–MS–MS) using selected reaction monitoring with an internal standard. By setting the nebulizer probe temperature to 475°C, we were able to use a mobile phase containing oxalic acid without clogging problems at the APCI interface, since oxalic acid decomposes to carbon dioxide and water at high temperature. DMCTC was very effective as an internal standard for determining TCs in various foods. TCs were cleaned up using a Bond Elut ENV cartridge and analysed by APCI LC–MS–MS. The recovery of TCs from various foods including animal tissues, honey, milk, eggs, and fish fortified at levels of 0.05, 0.10, and 0.50 ppm averaged 60.1–88.9%, with an RSD of 1.2–8.7%. The detection limits were 0.001 ppm for OTC and TC, 0.004 ppm for CTC, and 0.002 ppm for DC. The present method was also successfully used to determine TCs in swine kidney samples that were previously found by microbiological assay.  相似文献   

17.
A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-fluorouracil in monkey serum. A liquid/liquid extraction with ethyl acetate (90%) and isopropyl alcohol (10%) was used to extract simultaneously doxifluridine and 5-FU which have considerable difference in the polarity. Optimum chromatographic separation was achieved on a Agilent Zorbax C(18) (100 mm x 2.1mm, 3.5 microm) column with a mobile phase of methanol-water (20:80, v/v). The flow rate was 0.2 mL/min with total cycle time of 5 min. The lower limit of quantification (LLOQ) was validated at 10.0 ng/mL of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both compounds met FDA Guidance criteria of +/-15% with average QC accuracy of 95.5-105.0% and coefficients of variation of 1.1-9.5% in the 10-2000 ng/mL concentration range. This method demonstrated adequate sensitivity, specificity, accuracy, precision, stability to support the analysis of monkey serum samples.  相似文献   

18.
Understanding the intricate metabolic processes involved in plant cell wall biosynthesis is limited by difficulties in performing sensitive quantification of many involved compounds. Hydrophilic interaction liquid chromatography is a useful technique for the analysis of hydrophilic metabolites from complex biological extracts and forms the basis of this method to quantify plant cell wall precursors. A zwitterionic silica-based stationary phase has been used to separate hydrophilic nucleotide sugars involved in cell wall biosynthesis from milligram amounts of leaf tissue. A tandem mass spectrometry operating in selected reaction monitoring mode was used to quantify nucleotide sugars. This method was highly repeatable and quantified 12 nucleotide sugars at low femtomole quantities, with linear responses up to four orders of magnitude to several 100 pmol. The method was also successfully applied to the analysis of purified leaf extracts from two model plant species with variations in their cell wall sugar compositions and indicated significant differences in the levels of 6 out of 12 nucleotide sugars. The plant nucleotide sugar extraction procedure was demonstrated to have good recovery rates with minimal matrix effects. The approach results in a significant improvement in sensitivity when applied to plant samples over currently employed techniques.  相似文献   

19.
A method for the simultaneous determination of cyclophosphamide (CP), doxorubicin (dox), and doxorubicinol (dol) was developed and validated to analyze 400 microL of plasma from patients receiving chemotherapeutic treatment with CP and dox. Final calibration ranges for the analytes were 0.440-60.0 microg/mL for cyclophosphamide, 7.20-984 ng/mL for dox and 3.04-104 ng/mL for dol. The samples were prepared using solid phase extraction and analyzed using a gradient separation over a Waters Symmetry C18, 2.1 by 30 mm (Milford, MA) column. Detection was achieved in positive mixed reaction monitoring mode on a triple quadrupole mass spectrometer.  相似文献   

20.
Quantitative analysis of therapeutic compounds and their metabolites in biological matrix (such as plasma, serum or urine) nowadays requires sensitive and selective methods to allow the determination of concentrations in the ng/ml range. A new on-line LC–MS–MS method using atmospheric pressure chemical ionisation (APCI) as interface for the simultaneous determination of nifedipine (NIF) and its metabolite in human plasma, dehydronifedipine (DNIF) has been developed. The compounds were extracted from plasma using solid-phase extraction (SPE) on disposable extraction cartridges (DECs). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with phenyl modified silica was first conditioned with methanol and water. The washing step was performed with water. Finally, the analytes were successively eluted with methanol and water. The liquid chromatographic (LC) separation of NIF and DNIF was achieved on a RP-18 stationary phase (4 μm). The mobile phase consisted of methanol–50 mM ammonium acetate solution (50:50, v/v). The LC was then coupled to tandem mass spectrometry with an APCI interface in the positive ion mode.

The method developed was validated. The absolute recoveries evaluated over the whole concentration range were 95±2% and 95±4% for NIF and DNIF, respectively. The method was found to be linear in the 0.5–100 ng/ml concentration range for the two analytes (r2=0.999 for both NIF and DNIF). The mean R.S.D. values for repeatability and intermediate precision were 2.9 and 3.0% for NIF and 2.2–4.7% for the metabolite.The method developed was successfully used to investigate the plasma concentration of NIF and DNIF in the pharmacokinetic studies.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号