首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel frit preparation method for one‐end tapered‐fused silica‐packed capillary columns in nano‐LC‐ESI MS was developed. A hollow‐fused silica capillary column with a tapered tip as nano‐spray emitter was filled with 5 μm C18 beads, and then a sintered frit about 0.25 mm in length was prepared at the tip by butane flame. A stainless steel protection tube with 0.5 mm id was used to control the length of the frit and to protect the packed C18 beads behind the sintered frit during the sintering. C18 sintered frits were evaluated by BSA tryptic digests with nano‐LC‐LTQ. The sintered frits did not produce post‐column band broadening due to very small volume (about 0.2 nL) and did not produce adsorption to sample. The sintered frit columns had good separation reproducibility and separation performance compared with self‐assembled particles frit columns and commercial columns.  相似文献   

2.
The mouse liver microsome proteome was investigated using ion trap MS combined with three separation workflows including SDS‐PAGE followed by reverse‐phase LC of in‐gel protein digestions (519 proteins identified); 2‐D LC of protein digestion (1410 proteins); whole protein separation on mRP heat‐stable column followed by 2‐D LC of protein digestions from each fraction (3‐D LC; 3703 proteins). The higher number of proteins identified in the workflow corresponded to the lesser percentage of run‐to‐run reproducibility. Gel‐based method yielded a number of predicted membrane proteins similar to LC‐based workflows.  相似文献   

3.
Oxcarbazepine is a second‐generation antiepileptic drug indicated as monotherapy or adjunctive therapy in the treatment of partial seizures or generalized tonic–clonic seizures in adults and children. It undergoes rapid presystemic reduction with formation of the active metabolite 10‐hydroxycarbazepine (MHD), which has a chiral center at position 10, with the enantiomers (S)‐(+)‐ and R‐(?)‐MHD showing similar antiepileptic effects. This study presents the development and validation of a method of sequential analysis of oxcarbazepine and MHD enantiomers in plasma using liquid chromatography with tandem mass spectrometry (LC‐MS/MS). Aliquots of 100 μL of plasma were extracted with a mixture of methyl tert‐butyl ether: dichloromethane (2:1). The separation of oxcarbazepine and the MHD enantiomers was obtained on a chiral phase Chiralcel OD‐H column, using a mixture of hexane:ethanol:isopropanol (80:15:5, v/v/v) as mobile phase at a flow rate of 1.3 mL/min with a split ratio of 1:5, and quantification was performed by LC‐MS/MS. The limit of quantification was 12.5 ng oxcarbazepine and 31.25 ng of each MHD enantiomer/mL of plasma. The method was applied in the study of kinetic disposition of oxcarbazepine and the MHD enantiomers in the steady state after oral administration of 300 mg/12 h oxcarbazepine in a healthy volunteer. The maximum plasma concentration of oxcarbazepine was 1.2 µg/mL at 0.75 h. The kinetic disposition of MHD is enantioselective, with a higher proportion of the S‐(+)‐MHD enantiomer compared to R‐(?)‐MHD and an AUC0‐12 S‐(+)/R‐(?) ratio of 5.44. Chirality 25:897–903, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

4.
5.
The culture filtrate proteins (CFPs) from Mycobacterium tuberculosis have been shown to induce protective immune responses in human and animal models, making them a promising source of candidate targets for tuberculosis drugs, vaccines, and diagnostics. The constituents of the M. tuberculosis CFP proteome are complex and vary with growth conditions. To effectively profile CFPs, gel‐based prefractionation is usually performed before MS analysis. In this study, we describe a novel prefractionation approach by which the proteome is divided into seven partially overlapping fractions by biomimetic affinity chromatography (BiAC) using a six‐column cascade. The LC‐MS/MS analysis of individual fractions identified a total of 541 CFPs, including 61 first‐time identifications. Notably, ~1/3 (20/61) of these novel CFPs are membrane proteins, among which nine proteins have 2–14 transmembrane domains. In addition, ~1/4 (14/61) of the CFPs are basic proteins with pI values greater than 9.0. Our data demonstrate that biomimetic affinity chromatography prefractionation markedly improves protein detection by LC‐MS/MS, and the coverage of basic and hydrophobic proteins in particular is remarkably increased.  相似文献   

6.
Studies of neuronal, endocrine, and metabolic disorders would be facilitated by characterization of the hypothalamus proteome. Protein extracts prepared from 16 whole rat hypothalami were measured by data‐independent label‐free nano LC‐MS/MS. Peptide features were detected, aligned, and searched against a rat Swiss‐Prot database using ProteinLynx Global Server v.2.5. The final combined dataset comprised 21 455 peptides, corresponding to 622 unique proteins, each identified by a minimum of two distinct peptides. The majority of the proteins (69%) were cytosolic, and 16% were membrane proteins. Important proteins involved in neurological and synaptic function were identified including several members of the Ras‐related protein family and proteins involved in glutamate biosynthesis.  相似文献   

7.
Inositol 1,4,5‐trisphosohate (IP3) and its receptors play a pivotal role in calcium signal transduction in mammals. However, no homologs of mammalian IP3 receptors have been found in plants. In this study, we isolated the microsomal fractions from rice cells in suspension culture and further obtained putative IP3‐binding proteins by heparin‐agarose affinity purification. The IP3‐binding activities of these protein fractions were determined by [3H] IP3‐binding assay. SDS‐PAGE and MS analysis were then performed to characterize these proteins. We have identified 297 proteins from the eluates of heparin‐agarose column chromatography, which will provide insight into the IP3 signaling pathways in plants. All MS data have been deposited in the ProteomeXchange with identifier PXD000763 ( http://proteomecentral.proteomexchange.org/dataset/PXD000763 ).  相似文献   

8.
《Chirality》2017,29(10):603-609
d ‐ and l ‐Tryptophan (Trp) and d ‐ and l ‐kynurenine (KYN) were derivatized with a chiral reagent, (S )‐4‐(3‐isothiocyanatopyrrolidin‐1‐yl)‐7‐(N,N‐dimethylaminosulfonyl)‐2,1,3‐benzoxadiazole (DBD‐PyNCS), and were separated enantiomerically by high‐performance liquid chromatography (HPLC) equipped with a triazole‐bonded column (Cosmosil HILIC) using tandem mass spectrometric (MS/MS) detection. Effects of column temperature, salt (HCO2NH4) concentration, and pH of the mobile phase in the enantiomeric separation, followed by MS detection of (S )‐DBD‐PyNCS‐d ,l ‐Trp and ‐d ,l ‐KYN, were investigated. The mobile phase consisting of CH3CN/10 mM ammonium formate in H2O (pH 5.0) (90/10) with a column temperature of 50–60 °C gave satisfactory resolution (R s) and mass‐spectrometric detection. The enantiomeric separation of d ,l ‐Trp and d ,l ‐KYN produced R s values of 2.22 and 2.13, and separation factors (α) of 1.08 and 1.08, for the Trp and KYN enantiomers, respectively. The proposed LC–MS/MS method provided excellent detection sensitivity of both enantiomers of Trp and KYN (5.1–19 nM).  相似文献   

9.
Quantitative glycomics represents an actively expanding research field ranging from the discovery of disease‐associated glycan alterations to the quantitative characterization of N‐glycans on therapeutic proteins. Commonly used analytical platforms for comparative relative quantitation of complex glycan samples include MALDI‐TOF‐MS or chromatographic glycan profiling with subsequent data alignment and statistical evaluation. Limitations of such approaches include run‐to‐run technical variation and the potential introduction of subjectivity during data processing. Here, we introduce an offline 2D LC‐MSE workflow for the fractionation and relative quantitation of twoplex isotopically labeled N‐linked oligosaccharides using neutral 12C6 and 13C6 aniline (Δmass = 6 Da). Additional linkage‐specific derivatization of sialic acids using 4‐(4,6‐dimethoxy‐1,3,5‐trizain‐2‐yl)‐4‐methylmorpholinium chloride offered simultaneous and advanced in‐depth structural characterization. The potential of the method was demonstrated for the differential analysis of structurally defined N‐glycans released from serum proteins of patients diagnosed with various stages of colorectal cancer. The described twoplex 12C6/13C6 aniline 2D LC‐MS platform is ideally suited for differential glycomic analysis of structurally complex N‐glycan pools due to combination and analysis of samples in a single LC‐MS injection and the associated minimization in technical variation.  相似文献   

10.
11.
Metoprolol is available for clinical use as a racemic mixture. The S‐(?)‐metoprolol enantiomer is the one expressing higher activity in the blockade of the β1‐adrenergic receptor. The α‐hydroxymetoprolol metabolite also has activity in the blockade of the β1‐adrenergic receptor. The present study describes the development and validation of a stereoselective method for sequential analysis of metoprolol and of α‐hydroxymetoprolol in plasma using high‐performance liquid chromatography with tandem mass spectrometry (LC‐MS/MS). 1‐ml aliquots of plasma were extracted with dichloromethane : diisopropyl ether (1:1, v/v). Metoprolol enantiomers and α‐hydroxymetoprolol isomers were separated on a Chiralpak AD column (Daicel Chemical Industries, New York, NY, USA) and quantitated by LC‐MS/MS. The limit of quantitation obtained was 0.2 ng of each metoprolol enantiomer/ml plasma and 0.1 ng/ml of each α‐hydroxymetoprolol isomer/ml plasma. The method was applied to the study of kinetic disposition of metoprolol in plasma samples collected up to 24 h after the administration of a single oral dose of 100‐mg metoprolol tartrate to a hypertensive parturient with a gestational age of 42 weeks. The clinical study showed that the metoprolol pharmakokinetics is enantioselective, with the observation of higher area under the curve (AUC)0?∞ values for S‐(?)‐metoprolol (AUCS‐(?)/AUCR‐(+) = 1.81) and the favoring of the formation of the new chiral center 1′R of α‐hydroxymetoprolol (AUC0?∞1′R/1′S = 2.78). Chirality, 25:1–7, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

12.
13.
Pulmonary tuberculosis (TB) caused by Mycobacterium tuberculosis is a chronic disease. Currently, there are no sufficiently validated biomarkers for early diagnosis of TB infection. In this study, a panel of potential serum biomarkers was identified between patients with pulmonary TB and healthy controls by using iTRAQ‐coupled 2D LC‐MS/MS technique. Among 100 differentially expressed proteins screened, 45 proteins were upregulated (>1.25‐fold at p < 0.05) and 55 proteins were downregulated (<0.8‐fold at p < 0.05) in the TB serum. Bioinformatics analysis revealed that the differentially expressed proteins were related to the response to stimulus, the metabolic and immune system processes. The significantly differential expression of apolipoprotein CII (APOCII), CD5 antigen‐like (CD5L), hyaluronan‐binding protein 2 (HABP2), and retinol‐binding protein 4 (RBP4) was further confirmed using immunoblotting and ELISA analysis. By forward stepwise multivariate regression analysis, a panel of serum biomarkers including APOCII, CD5L, and RBP4 was obtained to form the disease diagnostic model. The receiver operation characteristic curve of the diagnostic model was 0.98 (sensitivity = 93.42%, specificity = 92.86%). In conclusion, APOCII, CD5L, HABP2, and RBP4 may be potential protein biomarkers of pulmonary TB. Our research provides useful data for early diagnosis of TB.  相似文献   

14.
An analytical scheme was developed for the separation and detection of organoarsenicals using a zwitterionic stationary phase of hydrophilic interaction chromatography (ZIC®‐HILIC) coupled in parallel to electrospray ionization mass spectrometry (ESI‐MS) and to inductively coupled plasma mass spectroscopy (ICP‐MS). The optimization of separation and detection for organoarsenicals was mainly focused on the influence of the percentage of acetonitrile (MeCN) used as a major component of the mobile phase. Isocratic and gradient elution was applied by varying the MeCN percentage from 78 % to 70 % MeCN and 22 % to 30 % of an aqueous solution of ammonium acetate (125 mM NH4Ac; pH 8.3) on a ZIC®‐HILIC column (150 × 2.1 mm id, 3.5 μm), to allow for the separation and successful detection of nine organoarsenicals (i.e., 3‐nitro‐4‐hydroxyphenylarsonic acid (roxarsone, Rox), phenylarsonic acid (PAA), p‐arsanilic acid (p‐ASA), phenylarsine oxide (PAO), dimethylarsinate (DMA), methylarsonate (MMA), arsenobetaine (AsB), arsenocholine (AsC) and trimethylarsine oxide (TMAO)) within 45 min. All analytes were prepared in the mobile phase. The flow rate of the mobile phase, the splitting ratio between ICP‐MS and ESI‐MS detection, and the oxygen addition were adapted to ensure that there appeared a stably burning inductively coupled plasma. Furthermore, the analytical method was evaluated by the identification and quantification of AsB in the reference material DORM‐2 (dogfish muscle) resulting in a 95‐% recovery with respect to the AsB concentration in the extract.  相似文献   

15.
Phosphorylation is a reversible posttranslational protein modification which plays a pivotal role in intracellular signaling. Despite extensive efforts, phosphorylation site mapping of proteomes is still incomplete motivating the exploration of alternative methods that complement existing workflows. In this study, we compared tandem mass spectrometry (MS/MS) on matrix assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) and nano‐electrospray ionization (nESI) Orbitrap instruments with respect to their ability to identify phosphopeptides from complex proteome digests. Phosphopeptides were enriched from tryptic digests of cell lines using Fe‐IMAC column chromatography and subjected to LC‐MS/MS analysis. We found that the two analytical workflows exhibited considerable orthogonality. For instance, MALDI‐TOF MS/MS favored the identification of phosphopeptides encompassing clear motif signatures for acidic residue directed kinases. The extent of orthogonality of the two LC‐MS/MS systems was comparable to that of using alternative proteases such as Asp‐N, Arg‐C, chymotrypsin, Glu‐C and Lys‐C on just one LC‐MS/MS instrument. Notably, MALDI‐TOF MS/MS identified an unexpectedly high number and percentage of phosphotyrosine sites (~20% of all sites), possibly as a direct consequence of more efficient ionization. The data clearly show that LC‐MALDI MS/MS can be a useful complement to LC‐nESI MS/MS for phosphoproteome mapping and particularly so for acidic and phosphotyrosine containing peptides.  相似文献   

16.
Labetalol is clinically available as a mixture of two racemates (four stereoisomers). The stereoisomer (R,R) has as main activity the β1‐antagonism and the stereoisomer (S,R) is highly selective for the α1 adrenoceptor and is responsible for most of the α‐blocker activity. In the present investigation, a method for the analysis of labetalol stereoisomers in human plasma was developed and applied to pharmacokinetic studies. Plasma samples (0.5 ml) were extracted with methyl tert‐butyl ether at pH 9.5. The four labetalol stereoisomers were analyzed by LC‐MS/MS on a Chirobiotic® V column using a mobile phase consisting of methanol, acetic acid, and diethylamine, with a recovery of more than 90% for all four. The quantitation limit was 0.5 ng/ml and linearity was observed at 250 ng/ml plasma for each stereoisomer. Studies of precision and accuracy presented coefficients of variation and percentage inaccuracy of less than 15%, indicating that the method is precise and accurate. The method was applied to the study of the kinetic disposition of labetalol over a period of 12 h after oral administration of a single 100 mg dose to a hypertensive pregnant woman. The clinical study revealed stereoselectivity in the pharmacokinetics of labetalol, with a lower plasma proportion for the active stereoisomers (R,R)‐labetalol and (S,R)‐labetalol. The stereoselectivity observed after oral administration is due to the hepatic metabolism and the first pass effect, with an AUC(R,R)/AUC(S,S) ratio of 0.5. Chirality, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

17.
Modern nano‐HPLC systems are capable of extremely precise control of solvent gradients, allowing high‐resolution separation of peptides. Most proteomics laboratories use a simple linear analytical gradient for nano‐LC‐MS/MS experiments, though recent evidence indicates that optimized non‐linear gradients result in increased peptide and protein identifications from cell lysates. In concurrent work, we examined non‐linear gradients for the analysis of samples fractionated at the peptide level, where the distribution of peptide retention times often varies by fraction. We hypothesized that greater coverage of these samples could be achieved using per‐fraction optimized gradients. We demonstrate that the optimized gradients improve the distribution of peptides throughout the analysis. Using previous generation MS instrumentation, a considerable gain in peptide and protein identifications can be realized. With current MS platforms that have faster electronics and achieve shorter duty cycle, the improvement in identifications is smaller. Our gradient optimization method has been implemented in a simple graphical tool (GOAT) that is MS‐vendor independent, does not require peptide ID input, and is freely available for non‐commercial use at http://proteomics.swmed.edu/goat/  相似文献   

18.
To study the soybean plasma membrane proteome under osmotic stress, two methods were used: a gel‐based and a LC MS/MS‐based proteomics method. Two‐day‐old seedlings were subjected to 10% PEG for 2 days. Plasma membranes were purified from seedlings using a two‐phase partitioning method and their purity was verified by measuring ATPase activity. Using the gel‐based proteomics, four and eight protein spots were identified as up‐ and downregulated, respectively, whereas in the nanoLC MS/MS approach, 11 and 75 proteins were identified as up‐ and downregulated, respectively, under PEG treatment. Out of osmotic stress responsive proteins, most of the transporter proteins and all proteins with high number of transmembrane helices as well as low‐abundance proteins could be identified by the LC MS/MS‐based method. Three homologues of plasma membrane H+‐ATPase, which are transporter proteins involved in ion efflux, were upregulated under osmotic stress. Gene expression of this protein was increased after 12 h of stress exposure. Among the identified proteins, seven proteins were mutual in two proteomics techniques, in which calnexin was the highly upregulated protein. Accumulation of calnexin in plasma membrane was confirmed by immunoblot analysis. These results suggest that under hyperosmotic conditions, calnexin accumulates in the plasma membrane and ion efflux accelerates by upregulation of plasma membrane H+‐ATPase protein.  相似文献   

19.
The peptide‐based quantitation accuracy and precision of LC‐ESI (QSTAR Elite) and LC‐MALDI (4800 MALDI TOF/TOF) were compared by analyzing identical Escherichia coli tryptic digests containing iTRAQ‐labeled peptides of defined abundances (1:1, 2.5:1, 5:1, and 10:1). Only 51.4% of QSTAR spectra were used for quantitation by ProteinPilot Software versus 66.7% of LC‐MALDI spectra. The average protein sequence coverages for LC‐ESI and LC‐MALDI were 24.0 and 18.2% (14.9 and 8.4 peptides per protein), respectively. The iTRAQ‐based expression ratios determined by ProteinPilot from the 57 467 ESI‐MS/MS and 26 085 MALDI‐MS/MS spectra were analyzed for measurement accuracy and reproducibility. When the relative abundances of peptides within a sample were increased from 1:1 to 10:1, the mean ratios calculated on both instruments differed by only 0.7–6.7% between platforms. In the 10:1 experiment, up to 64.7% of iTRAQ ratios from LC‐ESI MS/MS spectra failed S/N thresholds and were excluded from quantitation, while only 0.1% of the equivalent LC‐MALDI iTRAQ ratios were rejected. Re‐analysis of an archived LC‐MALDI sample set stored for 5 months generated 3715 MS/MS spectra for quantitation, compared with 3845 acquired originally, and the average ratios differed by only 3.1%. Overall, MS/MS‐based peptide quantitation performance of offline LC‐MALDI was comparable with on‐line LC‐ESI, which required threefold less time. However, offline LC‐MALDI allows the re‐analysis of archived HPLC‐separated samples.  相似文献   

20.
Protein glycosylation involves the addition of monosaccharides in a stepwise process requiring no glycan template. Therefore, identifying the numerous glycoforms, including isomers, can help elucidate the biological function(s) of particular glycans. A method to assess the diversity of the N‐linked oligosaccharides released from human serum without derivatization has been developed using on‐line nanoLC and high resolution TOF MS. The N‐linked oligosaccharides were analyzed with MALDI FT‐ICR MS and microchip LC MS (HPLC–Chip/TOF MS). Two microfluidic chips were employed, the glycan chip (40 nL enrichment column, 43×0.075 mm2 i.d. analytical column) and the high capacity chip (160 nL enrichment column, 140×0.075 mm2 i.d. analytical column), both with graphitized carbon as the stationary phase. Both chips offered good sensitivity and reproducibility in separating a heterogeneous mixture of neutral and anionic oligosaccharides between injections. Increasing the length and volume of the enrichment and the analytical columns improved resolution of the peaks. Complex type N‐linked oligosaccharides were the most abundant oligosaccharides in human serum accounting for ∼96% of the total glycans identified, while hybrid and high mannose type oligosaccharides comprise the remaining ∼4%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号