首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cai Y  Li H  Li Y  Zhao Y  Ma H  Zhu B  Xu C  Wei Q  Wu D  Du B 《Biosensors & bioelectronics》2012,36(1):6-11
Interests in using nanoporous metals for biosensing applications have been increasing. Herein, nanotubular mesoporous PdCu (NM-PdCu) alloy is used to fabricate a novel label-free electrochemical immunosensor for cancer biomarker carcinoembryonic antigen (CEA). It operates through physisorption of anti-CEA on NM-PdCu and the mixture of sulfonated graphene sheets (HSO(3)-GS) and thionine (TH) functionalized glassy carbon electrode interface as the detection platform. In this study, chitosan (CS)-PdCu is bound very strongly to carcinoembryonic antibody (anti-CEA), because of the good electron conductivity, high surface area, and good biocompatibility. CS-PdCu is immobilized on electrodes by electrostatic interactions between the negatively charged sulfo group of HSO(3)-GS and the abundant positively charged amino groups of chitosan. TH acts as the redox probe. Under the optimized conditions, the electrochemical immunosensor exhibits a wide working range from 0.01 to 12 ng/mL with a low detection limit of 4.86 pg/mL. The accuracy, reproducibility, and stability of the immunosensor are acceptable. The assay is evaluated for real serum samples, receiving satisfactory results. The nanoporous metal materials-based immunoassay provides a promising approach in clinical application and thus represents a versatile detection method.  相似文献   

2.
A label-free multiplexed immunoassay strategy was proposed for the simultaneous detection of two tumor markers, carcinoembryonic antigen (CEA) and α-fetoprotein (AFP). Monoclonal antibody of CEA was co-immobilized with ferrocenecarboxylic acid (FCA) inside the channels of mesoporous silica (MPS) to prepare the label-free probe for CEA. Also, monoclonal antibody of AFP was co-immobilized with horseradish peroxidase (HRP) inside the channels of MPS to prepare the label-free probe for AFP by using o-phenylenediamine (OPD) and H(2)O(2) as the electrochemical substrates. Thus, the multianalyte immunosensor was constructed by coating the probes of CEA and AFP respectively onto the different areas of indium-tin oxide (ITO) electrode. When the immunosensor was incubated with sample antigens, CEA and AFP antigens were introduced into the mesopores of MPS after the immunoassay reaction. Because all of the Si-OH groups on the external surface of MPS were blocked with Si(CH(3))(3), the proteins and substrates were limited to be embedded on the internal pore walls. Therefore, the electric response transfer was confined inside the pore channels. The nonconductive immunoconjugates blocked the electron transfer and the peak responses changed on the corresponding surface respectively. Then, the simultaneous detection of CEA and AFP achieved. The linear ranges of CEA and AFP were 0.5-45ngmL(-1) and 1-90ngmL(-1) with the detection limits of 0.2ngmL(-1) and 0.5ngmL(-1) (S/N=3), respectively. The fabricated immunosensor shows appropriate sensitivity and offers an alternative to the multianalyte detection of antigens or other bioactive molecules.  相似文献   

3.
A sensitive amperometric immunosensor for carcinoembryonic antigen (CEA) was prepared. Firstly, a porous nano-structure gold (NG) film was formed on glassy carbon electrode (GCE) by electrochemical reduction of HAuCl4 solution, then nano-Au/Chit composite was immobilized onto the electrode because of its excellent membrane-forming ability, and finally the anti-CEA was adsorbed onto the surface of the bilayer gold nanoparticles to construct an anti-CEA/nano-Au/Chit/NG/GCE immunosensor. The characteristics of the modified electrode at different stages of modification were studied by cyclic voltammetry (CV). The gold colloid, chitosan and nano-Au/Chit were characterized by transmission electron microscopy and UV–vis spectroscopy. In addition, the performances of the immunosensor were studied in detail. The resulting immunosensor offers a high-sensitivity (1310 nA/ng/ml) for the detection of CEA and has good correlation for detection of CEA in the range of 0.2 to 120.0 ng/ml with a detection limit of 0.06 ng/ml estimated at a signal-to-noise ratio of 3. The proposed method can detect the CEA through one-step immunoassay and would be valuable for clinical immunoassay.  相似文献   

4.
In this article, a novel sandwich-type electrochemical immunosensor based on the signal amplification strategy of diazotization-coupling concept for ultrasensitive detection of carcinoembryonic antigen (CEA) was reported. It operates through physisorption of monoclonal anti-CEA on 4-aminothiophenol (4Atp) functionalized gold electrode interface as the detection platform. Diazo-4Atp-coupled-thionine (Thi)-conjugated gold nanoparticles (GNPs) were prepared for immobilization of horseradish peroxidase (HRP) and secondary anti-CEA to form core-shell bioconjugates that were used as electrochemical signal amplification reagent. The sensitivity of the immunosensor was greatly amplified by a dual amplification: one is that a large number of thionine and HRP was introduced on the electrode surface through sandwich immunoreaction, the other is that HRP as enhancer could catalyze the oxidation reaction of thionine by H(2)O(2), which results in great enhancement of the reduction peak current. Thus, the bioconjugates-based assay provided an amplification approach for detecting CEA at trace levels and led to a detection limit as low as 0.7 pg/mL (at a three times signal-to-noise ratio) that is well-below the threshold value of 2.5 ng/mL for clinical diagnosis. The assay was evaluated for clinical serum samples with various CEA concentrations and received in excellent accordance with the results obtained from the referenced enzyme-linked immunosorbent assay (ELISA).  相似文献   

5.
A novel and convenient immunosensor, based on the electrostatic adsorption characteristics between the positively charged MnO2 nanoparticles (nano-MnO2) and chitosan (CS) composite membrane (nano-MnO2 + CS) and the negatively charged prussian blue (PB), was prepared for the detection of carcinoembryonic antigen (CEA). Firstly, PB was electro-deposited on the surface of the gold electrode in the constant potential, and then nano-MnO2 + CS was adsorbed onto PB-modified electrode surface. Subsequently, Gold nanoparticles (nano-Au) were electro-deposited on the nano-MnO2 + CS-modified electrode to immobilize antibody CEA (anti-CEA). Finally, bovine serum albumin (BSA) was employed to block sites against nonspecific binding. In our study, cyclic voltammetry (CV) and scanning electron microscopy (SEM) were used to characterize the fabricated process of the immunosensor. The immunosensor put up a rapid response time, high sensitivity and stability. Under the optimized conditions, cyclic voltammograms(CVs) determination of CEA displayed a broader linear response to CEA in two ranges, from 0.25 to 8.0 ng/mL, and from 8.0 to 100 ng/mL, with a relative low-detection limit of 0.083 ng/mL at three times the background and noise. The originality of the preparation of the immunosensor lies in not only using the synergistic effect of two kinds of nanomaterials (nano-MnO2 and nano-Au) to immobilize anti-CEA, but also using nano-MnO2 + CS to furnish a media transferring electron path. What is more, the researched methodology was efficient and potentially attractive for clinical immunoassays.  相似文献   

6.
In this article, a novel, label-free, and inherent electroactive redox immunosensor for carcinoembryonic antigen (CEA) based on gold nanoparticles (AuNPs) and Nile blue A (NB) hybridized electrochemically reduced graphene oxide (NB–ERGO) is proposed. The composite of NB–graphene oxide (NB–GO) was prepared by π–π stacking interaction. Then, chronoamperometry was adopted to simultaneously reduce HAuCl4 and nanocomposites of NB–GO for synthesizing AuNPs/NB–ERGO. The immunosensor was fabricated by capturing CEA antibody (anti-CEA) at this nanocomposite modified electrode. The immunosensor determination was based on the fact that, due to the formation of antigen–antibody immunocomplex, the decreased response currents of NB were directly proportional to the concentrations of CEA. Under optimal conditions, the linear range of the proposed immunosensor was estimated to be from 0.001 to 40 ng ml−1 and the detection limit was estimated to be 0.00045 ng ml−1. The proposed immunosensor was used to determine CEA in clinical serum samples with satisfactory results. The proposed method may provide promising potential application in clinical immunoassays with the properties of facile procedure, stability, high sensitivity, and selectivity.  相似文献   

7.
In this study, an immunosensor chip utilizing surface plasmon resonance (SPR) and cyclic voltammetry (CV) was fabricated for detecting carcinoembryonic antigen (CEA). Specifically, we applied in parallel an SPR instrument and a CV device to monitor the assembly of carcinoembryonic antibody (anti-CEA) on a protein A-conjugated surface and the subsequent ligand reaction. The immunosensor chips were constructed by various concentrations of protein A. To determine the surface characteristics of different self-assembly monolayers (SAMs), several quantitative and kinetic measurements were carried out. The extent of immobilization of anti-CEA and the immune response of anti-CEA antibody against CEA were measured using the SPR instrument and CV device. The terminal functional groups of protein A have different effects on the adsorption and covalent binding of immunoprotein depending on the steric hindrance. Through the parallel measurements, we demonstrate that SPR and CV are sensitive to measure the antigen–antibody binding capacity.  相似文献   

8.
The long-term stability of sensing interfaces is an important issue in biosensor fabrication. A novel stable gold nanoparticle (AuNP)-modified glassy carbon (GC) electrode interface (GC-Ph-AuNP)-based biosensor for detecting carcinoembryonic antigen (CEA) was developed. GC electrodes were modified with 1,4-phenylenediamine to form a stable layer, and then AuNPs were bound onto the GC electrodes through CAu bonds. Anti-CEA was directly adsorbed on AuNPs fixed on the GC electrode. The linear range of the immunosensor was from 10 fg to 100 ng mL(-1) with a detection limit of 3 fg mL(-1) (S/N=3). The current of the immunosensor was increased by 4% after one month. The GC-Ph-AuNP immunosensor showed high sensitivity, a wide linear range, low detection limit, and good selectivity and stability. The immobilization method of the immunosensor could be widely applied to construct other immunosensors.  相似文献   

9.
Wei Q  Zhao Y  Xu C  Wu D  Cai Y  He J  Li H  Du B  Yang M 《Biosensors & bioelectronics》2011,26(8):3714-3718
Nanoporous gold (NPG) film modified electrode for the construction of novel label-free electrochemical immunosensor for ultrasensitive detection of cancer biomarker prostate specific antigen (PSA) is described. Due to its high conductivity, large surface area, and good biocompatibility, NPG film modified electrode was used for the adsorption of anti-PSA antibody (Ab). The sensing signal is based on the monitoring of the electrode's current response towards K(3)Fe(CN)(6), which is extremely sensitive to the formation of immunocomplex within the nanoporous film. Under optimum conditions, the amperometric signal decreases linearly with PSA concentration (0.05-26 ng/mL), resulting in a low limit of detection (3 pg/mL). We demonstrated the application of the novel immunosensor for the detection of PSA in real sample with satisfactory results.  相似文献   

10.
Electrodes modified with passivating organic layers have been shown to, here and previously, to exhibit good Faradaic electrochemistry upon attachment of gold nanoparticles (AuNP). Due to their low background capacitances these constructs have good potential in electrochemical sensing. Herein is reported the application of these electrode constructs for impedance based immunosensing. The immunosensor was constructed by modifying a gold electrode with 4-thiophenol (4-TP) passivating layers by diazonium salt chemistry. Subsequently, the attachment of AuNP and then a biotin derivative as a model epitope to detect anti-biotin IgG were carried out. The interfacial properties of the modified electrodes were evaluated in the presence of Fe(CN)(6)(4-/3-) redox couple as a probe by cyclic voltammetry and electrochemical impedance spectroscopy. The impedance change, due to the specific immuno-interaction at the immunosensor surface was utilized to detect anti-biotin IgG. The increase in charge-transfer resistance (R(ct)) was linearly proportional to the concentration of anti-biotin IgG in the range of 5-500 ng mL(-1), with a detection limit of 5 ng mL(-1).  相似文献   

11.
Zeng G  Yang P  Zheng Z  Feng Q  Cai J  Zhang S  Chen ZW 《Proteomics》2005,5(17):4347-4353
While biosensors have been constructed using various strategies, there is no report describing nanostructures of antibody-immobilized electrode interface in an immunosensor. Here, atomic force microscopy (AFM) and electrochemistry analyses were employed to construct and characterize the nanostructures and electrochemistry of biosensing surface that was created by a sequential self-assembling of bioactive aminobenzenthiol oligomer (o-ABT), glutareldehyde and anti-transferrin (anti-Tf) antibody on the electrode gold surface. Under AFM, a complete coverage of bioactive o-ABT interface could be achieved by anti-Tf antibody at an optimal concentration. The anti-Tf antibody immobilized on electrode surface of the immunosensor exhibited globular-shape topography with some degree of aggregation. Extensive force-curve analysis allowed mapping the functional spots of the anti-Tf immunosensor. Surprisingly, although immunosensing surface was fully covered by anti-Tf antibodies at the optimal concentration, only about 52% of coated anti-Tf antibody molecules (spots) on the electrode surface were able to specifically capture or bind Tf antigen under AFM. Despite limited functional spots, however, the anti-Tf immunosensor was highly specific and sensitive for sensitizing Tf antigen in solution. The anti-Tf molecules on the immunosensor exhibited a greater molecular force bound to holo-Tf (iron-containing form of Tf) than that to apo-Tf (iron-absent form of Tf). Consistently, the anti-Tf immunosensor had a greater electrochemical capacity to sensitize apo-Tf than holo-Tf, supporting the molecular force-based finding by AFM. Thus, the present study elucidated the nanostructures and molecular force bases for the immunosensing capacity of a highly sensitive capacitive immunosensor.  相似文献   

12.
A new amperometric immunosensor for the determination of carcinoembryonic antigen (CEA) was constructed. First, the uniform nanomultilayer film was fabricated via layer-by-layer (LBL) assembly of positively charged carbon nanotubes wrapped by poly(diallyldimethylammonium chloride) and negatively charged poly(sodium-p-styrene-sulfonate), which could provide a high accessible surface area and a biocompatible microenvironment. Subsequently, gold nanoclusters were electrodeposited on the electrode to immobilize anti-CEA. The fabricated process and electrochemical behaviors of the immunosensor were characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor could detect CEA in two linear ranges from 0.1 to 2.0 ng mL−1 and from 2.0 to 160.0 ng mL−1, with a detection limit of 0.06 ng mL−1.  相似文献   

13.
A new current amplified immunosensor for the determination of carcinoembryonic antigen (CEA) was demonstrated in this work. The electrode architecture was fabricated by positively charged toluidine blue (TB) coated on negatively charged poly-sulfanilic acid (PSAA) modified glassy carbon electrode (GCE) surface through electrostatic interactions to form a TB/PSAA film, which provided an interface containing amine groups to assemble gold nanoparticles (nano-Au) for immobilization of carcinoembryonic antibody (anti-CEA) and horseradish peroxidase (HRP) instead of bovine serum albumin (BSA) to block sites against non-specific binding. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed to characterize the electrochemical properties of the modified processes. The CVs reduction current of the immunosensor charged linearly in two concentration ranges of CEA from 0.5 to 5.0 and 5.0 to 120.0 ng/ml in presence of 0.3mM H2O2 in analyte solution, and the detection limit was 0.2 ng/ml at three times background noise. The proposed method is economical, efficient and potentially attractive for clinical immunoassays.  相似文献   

14.
A sensitive label-free electrochemical immunosensing platform was designed by a redox matrix of gold nanoparticles (GNPs), Azure І and multi-wall carbon nanotubes (MWCNT) self-assemblying nanocomposite. To construct the immunosensor, MWCNT was first dispersed in Nafion (Nf) to obtain a homogeneous solution and then it was dropped on the surface of the gold electrode (Au). Then the positively-charged redox molecule, Azure І, was entrapped into MWCNT–Nf film to form a redox nanostructural membrane. Next, the negatively charged gold nanoparticles (GNPs) were assembled to the interface through the electrostatic force. Finally, carcinoembryonic antibody molecules could be absorbed into the GNPs/Azure І/MWCNT–Nf immobilization matrix. Using carcinoembryonic antigen (CEA) as a model protein, the electrochemical immunosensor exhibited good stability and reproducibility, as well as good selectivity and storage stability. This strategy presented a promising platform for sensitive and facile monitoring of CEA.  相似文献   

15.
Anti-idiotype antibodies can mimic the conformational epitopes of the original antigen and act as antigen substitutes for vaccination and/or serological purposes. To investigate this possibility concerning the tumor marker carcinoembryonic antigen (CEA), BALB/c mice were immunized with the previously described anti-CEA monoclonal antibody (MAb) 5.D11 (AB1). After cell fusion, 15 stable cloned cell lines secreting anti-Ids (AB2) were obtained. Selected MAbs gave various degrees of inhibition (up to 100%) of the binding of 125I-labeled CEA to MAb 5.D11. Absence of reactivity of anti-Id MAbs with normal mouse IgG was first demonstrated by the fact that anti-Id MAbs were not absorbed by passage through a mouse IgG column, and second because they bound specifically to non-reduced MAb 5.D11 on Western blots. Anti-5.D11 MAbs did not inhibit binding to CEA of MAb 10.B9, another anti-CEA antibody obtained in the same fusion as 5.D11, or that of several anti-CEA MAbs reported in an international workshop, with the exception of two other anti-CEA MAbs, both directed against the GOLD IV epitope. When applied to an Id-anti-Id competitive radioimmunoassay, a sensitivity of 2 ng/ml of CEA was obtained, which is sufficient for monitoring circulating CEA in carcinoma patients. To verify that the anti-Id MAbs have the potential to be used as CEA vaccines, syngeneic BALB/c mice were immunized with these MAbs (AB2). Sera from immunized mice were demonstrated to contain AB3 antibodies recognizing the original antigen, CEA, both in enzyme immunoassay and by immunoperoxidase staining of human colon carcinoma. These results open the perspective of vaccination against colorectal carcinoma through the use of anti-idiotype antibodies as antigen substitutes.  相似文献   

16.
[AuCl4] was initially deposited by electrochemical reduction on a glassy carbon electrode (GCE) to form porous nanogold layer, then prussian blue (PB) was electrodeposited onto the as-prepared nanogold layer, and then secondary nanogold particles were fabricated again on the PB surface by electrochemical reduction for the immobilization of anti-CEA antibodies. The presence of double-layer porous gold nanoparticles enhanced the immobilized amount of biomolecules, and improved the sensitivity of the immunoassay. PB, as a good redox probe, was facile to electrochemical analysis and measurement. Under optimal conditions, the developed immunoassay exhibited dynamic range from 3.0 to 80.0 ng/mL with a detection limit of 0.9 ng/mL CEA (S/N = 3). Moreover, the selectivity, reproducibility and stability of the immunosensor were acceptable.  相似文献   

17.
An electrochemical impedimetric immunosensor was developed for ultrasensitive determination of insulin-like growth factor-1 (IGF-1) based on immobilization of a specific monoclonal antibody on gold nanoparticles (GNPs) modified gold electrode. Self-assembly of colloidal gold nanoparticles on the gold electrode was conducted through the thiol groups of 1,6-hexanedithiol (HDT) monolayer as a cross linker. The redox reactions of [Fe(CN)(6)](4-)/[Fe(CN)(6)](3-) on the electrode surface was probed for studying the immobilization and determination processes, using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The interaction of antigen with grafted antibody recognition layer was carried out by soaking the modified electrode into antigen solution at 37°C for 3 h. The immunosensor showed linearity over 1.0-180.0 pg mL(-1) and the limit of detection was 0.15 pg mL(-1). The association constant between IGF-1 and immobilized antibody was calculated to be 9.17×10(11) M(-1). The proposed method is a useful tool for screening picogram amounts of IGF-1 in clinical laboratory as a diagnostic test.  相似文献   

18.
A new simple immunoassay method for carcinoembryonic antigen (CEA) detection using a disposable immunosensor coupled with a flow injection system was developed. The immunosensor was prepared by coating CEA/colloid Au/chitosan membrane at a screen-printed carbon electrode (SPCE). Using a competitive immunoassay format, the immunosensor inserted in the flow system with an injection of sample and horseradish peroxidase (HRP)-labeled CEA antibody was used to trap the labeled antibody at room temperature for 35 min. The current response obtained from the labeled HRP to thionine-H(2)O(2) system decreased proportionally to the CEA concentration in the range of 0.50-25 ng/ml with a correlation coefficient of 0.9981 and a detection limit of 0.22 ng/ml (S/N=3). The immunoassay system could automatically control the incubation, washing and current measurement steps with good stability and acceptable accuracy. Thus, the proposed method proved its potential use in clinical immunoassay of CEA.  相似文献   

19.
A simple and sensitive label-free electrochemical immunoassay electrode for detection of carcinoembryonic antigen (CEA) has been developed. CEA antibody (CEAAb) was covalently attached on glutathione (GSH) monolayer-modified gold nanoparticle (AuNP) and the resulting CEAAb-AuNP bioconjugates were immobilized on Au electrode by electro-copolymerization with o-aminophenol (OAP). Electrochemical impedance spectroscopy and cyclic voltammetry studies demonstrate that the formation of CEA antibody-antigen complexes increases the electron transfer resistance of [Fe(CN)(6)](3-/4-) redox pair at the poly-OAP/CEAAb-AuNP/Au electrode. The use of CEA antibody-AuNP bioconjugates and poly-OAP film could enhance the sensitivity and anti-nonspecific binding of the resulting immunoassay electrode. The preliminary application of poly-OAP/CEAAb-AuNP/Au electrode for detection of CEA was also evaluated.  相似文献   

20.
A novel experimental methodology for studying a mediatorless and label-free immunosensor is proposed by immobilizing antibody on gold nanoparticle/L-cysteine coated electrode (nano-Au/L-cysteine electrode). Differential pulse voltammograms (DPV) resulting from the assembled immunosensor indicate that the immunosensor shows excellent electrochemical response to dopamine so that the electrochemical response is utilized for the signal generation step of the immunosensor. Therefore, by means of unenzymatic-labeling procedure combined with the amperometric detection using dopamine as substrate, the immunological reaction can be detected. After the immunosensor is incubated with h-IgG solution, the access of electrocatalytic behavior center of the immunosensor to dopamine is partly inhibited, which leads to a linear decrease in amperometric response of the immunosensor with h-IgG concentration over a range 0.82-90 ng mL(-1) by DPV.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号