首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two classes of polymers that are currently receiving widespread attention in biosensor development are hydrogels and conducting electroactive polymers. The present study reports on the integration of these two materials to produce electroactive hydrogel composites that physically entrap enzymes within their matrices for biosensor construction and chemically stimulated controlled release. Enhanced biosensing capabilities of these membranes have been demonstrated in the fabrication of glucose, cholesterol and galactose amperometric biosensors. All biosensors displayed extended linear response ranges (10(-5)-10(-2) M), rapid response times (<60 s), retained storage stabilities of up to 1 year, and excellent screening of the physiological interferents ascorbic acid, uric acid, and acetaminophen. When the cross-linked hydrogel components of these composite membranes were prepared with the amine containing dimethylaminoethyl methacrylate monomer the result was polymeric devices that swelled in response to pH changes (neutral to acidic). Entrapment of glucose oxidase within these materials made them glucose-responsive through the formation of gluconic acid. When insulin was co-loaded with glucose oxidase into these "bio-smart" devices, there was a twofold increase in insulin release rate when the devices were immersed in glucose solutions. This demonstrates the potential of such systems to function as a chemically-synthesized artificial pancreas.  相似文献   

2.
A simple and controllable electrodeposition approach was established for one-step construction of hydrogen peroxide (H(2)O(2)) biosensors by in situ formation of chitosan-ionic liquid-horseradish peroxidase (CS-IL-HRP) biocomposite film on electrode surface. A highly porous surface with orderly three-dimensional network was revealed by scanning electron microscopy (SEM) investigation. The biocomposite provided improved conductivity and biocompatible microenvironment. The developed biosensor exhibited a fast amperometric response for the determination of H(2)O(2) and 95% of the steady-state current was obtained within 2s. The linear response of the developed biosensor for the determination of H(2)O(2) ranged from 6.0x10(-7) to 1.6x10(-4)M with a detection limit of 1.5x10(-7)M. Performance of the biosensor was evaluated with respect to possible interferences and a good selectivity was revealed. The fabricated biosensor exhibited high reproducibility and long-time storage stability. The ease of the one-step non-manual technique and the promising feature of biocomposite could serve as a versatile platform for the fabrication of electrochemical biosensors.  相似文献   

3.
An uric acid biosensor fabricated from a uricase-immobilized eggshell membrane and an oxygen electrode was presented. The detection schemes involve the enzymatic reactions of the uricase leading to the depletion of dissolved oxygen level upon exposure to uric acid solution. The decrease in oxygen level was monitored and related to the uric acid concentration. The scanning electron micrographs show the microstructure of the eggshell membrane within which the uricase is successfully immobilized. The effects of enzyme loading, pH, temperature, and phosphate buffer concentration on the response of the biosensor were investigated in detail. The uric acid biosensor has a linear response range of 4.0-640 microM with a detection limit of 2.0 microM (S/N=3). The response time was less than 100 s. The biosensor exhibited good repeatable response to a 0.10mM uric acid solution with a relative standard deviation of 3.1% (n=7). The reproducibility of fabrication of the biosensors using four different membranes was good with a R.S.D. of 3.2%. The biosensor showed extremely good stability with a shelf-life of at least 3 months. Some common potential interferents in samples such as glucose, urea, ascorbic acid, lactic acid, glycine, DL-alpha-alanine, DL-cysteine, KCl, NaCl, CaCl2, MgSO4, and NH4Cl showed no interferences on the response of the uric acid biosensor. The biosensor was successfully applied to determine the uric acid level in some human serum and urine samples, and the results agreed well with those obtained by a commercial colorimetric assay kit.  相似文献   

4.
This work presents a novel, miniature optical biosensor by immobilizing horseradish peroxidase (HRP) or the HRP/glucose oxidase (GOx) coupled enzyme pair on a CMOS photosensing chip with a detection area of 0.5 mm × 0.5 mm. A highly transparent TEOS/PDMS Ormosil is used to encapsulate and immobilize enzymes on the surface of the photosensor. Interestingly, HRP-catalyzed luminol luminescence can be detected in real time on optical H2O2 and glucose biosensors. The minimum reaction volume of the developed optical biosensors is 10 μL. Both optical H2O2 and glucose biosensors have an optimal operation temperature and pH of 20–25 °C and pH 8.4, respectively. The linear dynamic range of optical H2O2 and glucose biosensors is 0.05–20 mM H2O2 and 0.5–20 mM glucose, respectively. The miniature optical glucose biosensor also exhibits good reproducibility with a relative standard deviation of 4.3%. Additionally, ascorbic acid and uric acid, two major interfering substances in the serum during electrochemical analysis, cause only slight interference with the fabricated optical glucose biosensor. In conclusion, the CMOS-photodiode-based optical biosensors proposed herein have many advantages, such as a short detection time, a small sample volume requirement, high reproducibility and wide dynamic range.  相似文献   

5.
Choline, as a marker of cholinergic activity in brain tissue, is very important in biological and clinical analysis, especially in the clinical detection of the neurodegenerative disorders disease. This work presents an electrochemical approach for the detection of choline based on prussian blue modified iron phosphate nanostructures (PB-FePO(4)). The obtained nanostructures showed a good catalysis toward the electroreduction of H(2)O(2), and an amperometric choline biosensor was developed by immobilizing choline oxidase on the PB-FePO(4) nanostructures. The biosensor exhibited a rapid response (ca. 2s), low detection limit (0.4±0.05 μM), wide linear range (2 μM to 3.2 mM), high sensitivity (~75.2 μAm M(-1) cm(-2)), as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid and 4-acetamidophenol did not cause obvious interference due to the low detection potential (-0.05 V versus saturated calomel electrode). This nanostructure could be used as a promise platform for the construction of other oxidase-based biosensors.  相似文献   

6.
Here we report on a novel platform based on buckypaper for the design of high-performance electrochemical biosensors. Using glucose oxidase as a model enzyme, we constructed a biocompatible mediator-free biosensor and studied the potential effect of the buckypaper on the stability of the biosensor with both amperometry and FTIR spectroscopy. The results showed that the biosensor responses sensitively and selectively to glucose with a considerable functional lifetime of over 80 days. The fabricated enzymatic sensor detects glucose with a dynamic linear range of over 9 mM and a detection limit of 0.01 mM. To examine the efficiency of enzyme immobilization, the Michaelis–Menten constant was calculated to be 4.67 mM. In addition, the fabricated electrochemical biosensor shows high selectivity; no amperometric response to the common interference species such as ascorbic acid, uric acid and acetamidophenol was observed. The facile and robust buckypaper-based platform proposed in this study opens the door for the design of high-performance electrochemical biosensors for medical diagnostics and environmental monitoring.  相似文献   

7.
Nanosized flower-like ZnO was synthesized by a simple hydrothermal method which is a convenient, environment friendly, inexpensive and efficient process. Raman spectroscopy, X-ray diffraction (XRD) and scanning electron microscope (SEM) were used to confirm the material structure and the crystallite microstructure. Then ZnO was dispersed in the chitosan solution to form a ZnO/chitosan composite matrix for the fabrication of H2O2 biosensor. This composite combined the advantages of inorganic species (ZnO) and organic polymer (chitosan). The parameters affecting the fabrication and experimental conditions of biosensors were optimized. Using hydroquinone as the mediator, the biosensor showed a fast response of less than 5s with the linear range of 1.0x10(-5) to 1.8x10(-3) M H2O2 with a correlation coefficient of 0.995 (n=20). The detection limit of the sensor was found to be 2.0 microM, based on a signal-to-noise ratio of 3. The biosensor exhibited satisfactory reproducibility and stability and retained about 78% of its original response after 40 days storage in a phosphate buffer at 4 degrees C.  相似文献   

8.
During the reversible reaction between peroxidase (HRP) and H(2)O(2), several peroxidase intermediate species, showing different molecular absorption spectra, are formed which can be used for H(2)O(2) determination; when H(2)O(2) is generated in a previous enzymatic reaction, the substrate involved in this reaction can also be determined. On this basis, a new family of fully reversible reagentless optical biosensors containing HRP is presented; glucose determination is used as a model. The biosensor (which can be used for at least 6 months and/or more than 750 measurements) is prepared by HRP and glucose oxidase entrapment in a polyacrylamide gel matrix. A mathematical model (in which optical, kinetic and transport aspects are considered) relating the measured absorbance with the substrate concentration is also presented together with a simple methodology for characterization of this kind of biosensor. Regarding the optical model, the Kubelka-Mulk theory of reflectance does not give good results and the biosensors are better described by the Rayleigh theory of polymer solutions. Under working conditions, linear response ranges from 1.5x10(-6) to 3.0x10(-4)M glucose and CV was about 4%. This biosensor has been applied for glucose determination in fruit juices and synthetic serum samples without sample pretreatment.  相似文献   

9.
Lu X  Zhou J  Lu W  Liu Q  Li J 《Biosensors & bioelectronics》2008,23(8):1236-1243
Carbon nanofibers (CNFs), with typical diameters of approximately 80 nm and lengths of the order of micrometers, are extremely attractive in bioanalytical area as they can combine properties of high surface area, non-toxicity, acceptable biocompatibility, ease of fabrication, chemical and electrochemical stability, good electrical conductivity. In this work, CNF-based composites were successfully used as an immobilization matrix for the construction of a reagentless mediator-free hemoglobin-based H2O2 biosensor. The results revealed that hemoglobin retained its essential secondary structure in the CNF-based composite film. With the advantages of organic-inorganic hybrid materials, dramatically facilitated direct electron transfer of hemoglobin and good bioelectrocatalytic activity towards H2O2 were demonstrated. The biosensor displayed good performance along with good long-term stability. The CNF-based composites were proved to be a promising biosensing platform for the construction of mediator-free biosensors, and may find wide potential applications in biosensors, biocatalysis, bioelectronics and biofuel cell.  相似文献   

10.
An electrodeposition method was applied to form gold-platinum (AuPt) alloy nanoparticles on the glassy carbon electrode (GCE) modified with a mixture of an ionic liquid (IL) and chitosan (Ch) (AuPt-Ch-IL/GCE). AuPt nanoparticles were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and electrochemical methods. AuPt-Ch-IL/GCE electrocatalyzed the reduction of H(2)O(2) and thus was suitable for the preparation of biosensors. Cholesterol oxidase (ChOx) was then, immobilized on the surface of the electrode by cross-linking ChOx and chitosan through addition of glutaraldehyde (ChOx/AuPt-Ch-IL/GCE). The fabricated biosensor exhibited two wide linear ranges of responses to cholesterol in the concentration ranges of 0.05-6.2 mM and 6.2-11.2 mM. The sensitivity of the biosensor was 90.7 μA mM(-1) cm(-2) and the limit of detection was 10 μM of cholesterol. The response time was less than 7 s. The Michaelis-Menten constant (K(m)) was found as 0.24 mM. The effect of the addition of 1 mM ascorbic acid and glucose was tested on the amperometric response of 0.5 mM cholesterol and no change in response current of cholesterol was observed.  相似文献   

11.
The lack of specific, low-cost, rapid, sensitive, and easy detection of biomolecules has resulted in the development of biosensor technology. Innovations in biosensor technology have enabled many biosensors to be commercialized and have enabled biomolecules to be detected onsite. Moreover, the emerging technologies of lab-on-a-chip microdevices and nanosensors offer opportunities for the development of new biosensors with much better performance. Biosensors were first introduced into the laboratory by Clark and Lyons. They developed the first glucose biosensor for laboratory conditions. Then in 1973, a glucose biosensor was commercialized by Yellow Springs Instruments. The commercial biosensors have small size and simple construction and they are ideal for point-of-care biosensing. In addition to glucose, a wide variety of metabolites such as lactate, cholesterol, and creatinine can be detected by using commercial biosensors. Like the glucose biosensors (tests) other commercial tests such as for pregnancy (hCG), Escherichia coli O157, influenza A and B viruses, Helicobacter pylori, human immunodeficiency virus, tuberculosis, and malaria have achieved success. Apart from their use in clinical analysis, commercial tests are also used in environmental (such as biochemical oxygen demand, nitrate, pesticide), food (such as glutamate, glutamine, sucrose, lactose, alcohol, ascorbic acid), and biothreat/biowarfare (Bacillus anthracis, Salmonella, Botulinum toxin) analysis. In this review, commercial biosensors in clinical, environmental, food, and biowarfare analysis are summarized and the commercial biosensors are compared in terms of their important characteristics. This is the first review in which all the commercially available tests are compiled together.  相似文献   

12.
Zhao H  Ju H 《Analytical biochemistry》2006,350(1):138-144
A bilayer of the polyelectrolytes poly(dimethyldiallylammonium chloride) (PDDA) and poly(sodium 4-styrenesulfonate) (PSS) was formed on a 3-mercapto-1-propanesulfonic-acid-modified Au electrode. Subsequently, multiwall carbon nanotubes (MWCNTs) wrapped by positively charged PDDA were assembled layer-by-layer with negatively charged glucose oxidase (GOx) onto the PSS-terminated bilayer. Electrochemical impedance spectroscopy and atomic force microscopy were adopted to monitor the regular growth of the PDDA-MWCNTs/GOx bilayers. Using GOx as a model enzyme, the assembled multilayer membranes showed some striking features such as the adsorbed form of GOx on individual MWCNT, uniformity, good stability, and electrocatalytic activity toward oxygen reduction. Based on the consumption of dissolved oxygen during the oxidation process of glucose catalyzed by the immobilized GOx, a sensitive amperometric biosensor was developed for the detection of glucose up to 5.0 mM with a detection limit of 58 microM. The sensitivity increased with increasing sensing layers up to five bilayers. Ascorbic acid and uric acid did not cause any interference due to the use of a low operating potential. The present method showed high reproducibility for the fabrication of carbon-nanotubes-based amperometric biosensors.  相似文献   

13.
In this study, the Fe-based layered double hydroxides (Mg(3)Fe LDH) were used to immobilize heme proteins including hemoglobin (Hb), myoglobin (Mb) and horseradish peroxidase (HRP) for fabrication of heme/Mg(3)Fe LDH film on glassy carbon electrode (Mg(3)Fe-heme/GCE). The possible role of iron in framework of LDH to promote direct electron transfer (DET) of heme proteins was investigated using an LDH containing non-iron as a reference. Hb was selected as a model protein for studying the electrocatalytic activity of immobilized heme in LDH film. The Mg(3)Fe-Hb/GCE displayed an enhanced electrocatalytic reduction towards H(2)O(2). The biosensor showed a very low detection limit (0.036μM) and apparent Michaelis-Menten constant (7.98μM). This work outlines that Fe-based LDH modified electrode provides a promising platform for immobilization of heme proteins and development of sensitive biosensors.  相似文献   

14.
Due to their unique physicochemical properties, doped carbon nanotubes are now extremely attractive and important nanomaterials in bioanalytical applications. In this work, selecting glucose oxidase (GOD) as a model enzyme, we investigated the direct electrochemistry of GOD based on the B-doped carbon nanotubes/glassy carbon (BCNTs/GC) electrode with cyclic voltammetry. A pair of well-defined, quasi-reversible redox peaks of the immobilized GOD was observed at the BCNTs based enzyme electrode in 0.1M phosphate buffer solution (pH 6.98) by direct electron transfer between the protein and the electrode. As a new platform in glucose analysis, the new glucose biosensor based on the BCNTs/GC electrode has a sensitivity of 111.57 microA mM(-1)cm(-2), a linear range from 0.05 to 0.3mM and a detection limit of 0.01mM (S/N=3). Furthermore, the BCNTs modified electrode exhibits good stability and excellent anti-interferent ability to the commonly co-existed uric acid and ascorbic acid. These indicate that boron-doped carbon nanotubes are the good candidate material for the direct electrochemistry of the redox-active enzyme and the construction of the related enzyme biosensors.  相似文献   

15.
The preparations and performances of the novel amperometric biosensors for glucose based on immobilized glucose oxidase (GOD) on modified Pt electrodes are described. Two types of modified electrodes for the enzyme immobilization were used in this study, polyvinylferrocene (PVF) coated Pt electrode and gold deposited PVF coated Pt electrode. A simple method for the immobilization of GOD enzyme on the modified electrodes was described. The enzyme electrodes developed in this study were called as PVF-GOD enzyme electrode and PVF-Au-GOD enzyme electrode, respectively. The amperometric responses of the enzyme electrodes were measured at constant potential, which was due to the electrooxidation of enzymatically produced H2O2. The electrocatalytic effects of the polymer, PVF, and the gold particles towards the electrooxidation of the enzymatically generated H2O2 offers sensitive and selective monitoring of glucose. The biosensor based on PVF-Au-GOD electrode has 6.6 times larger maximum current, 3.8 times higher sensitivity and 1.6 times larger linear working portion than those of the biosensor based on PVF-GOD electrode. The effects of the applied potential, the thickness of the polymeric film, the amount of the immobilized enzyme, pH, the amount of the deposited Au, temperature and substrate concentration on the responses of the biosensors were investigated. The optimum pH was found to be pH 7.4 at 25 degrees C. Finally the effects of interferents, stability of the biosensors and applicability to serum analysis of the biosensor were also investigated.  相似文献   

16.
Yu J  Wang S  Ge L  Ge S 《Biosensors & bioelectronics》2011,26(7):3284-3289
In this work, chemiluminescence (CL) method was combined with microfluidic paper-based analytical device (μPAD) to establish a novel CL μPAD biosensor for the first time. This novel CL μPAD biosensor was based on enzyme reaction which produced H(2)O(2) while decomposing the substrate and the CL reaction between rhodanine derivative and generated H(2)O(2) in acid medium. Microchannels in μPAD were fabricated by cutting method. And the possible CL assay principle of this CL μPAD biosensor was explained. Rhodanine derivative system was used to reach the purpose of high sensitivity and well-defined signal for this CL μPAD biosensor. And the optimum reaction conditions were investigated. The quantitative determination of uric acid could be achieved by this CL μPAD biosensor with accurate and satisfactory result. And this biosensor could provide good reproducible results upon storage at 4°C for at least 10 weeks. The successful integration of μPAD and CL reaction made the final biosensor inexpensive, easy-to-use, low-volume, and portable for uric acid determination, which also greatly reduces the cost and increases the efficiency required for an analysis. We believe this simple, practical CL μPAD biosensor will be of interest for use in areas such as disease diagnosis.  相似文献   

17.
Zou Y  Sun LX  Xu F 《Biosensors & bioelectronics》2007,22(11):2669-2674
In this work, a novel route for fabrication polyaniline (PANI)-Prussian Blue (PB) hybrid composites is proposed by the spontaneous redox reaction in the FeCl(3)-K(3)[Fe(CN)(6)] and the aniline solution. With the introduction of multi-walled carbon nanotubes (MWNTs), the PANI-PB/MWNTs system shows synergy between the PANI-PB and MWNTs which amplified the H(2)O(2) sensitivity greatly. A linear range from 8 x1 0(-8) to 1 x 10(-5)M and a high sensitivity 508.1 8 microA microM cm(2) for H(2)O(2) detection are obtained. The composites also show good stability in neutral solution. A glucose biosensor was further constructed by immobilizing glucose oxidase (GOD) with Nafion and glutaraldehyde on the electrode surface. The performance factors influencing the resulted biosensor were studied in detail. The biosensor exhibits excellent response performance to glucose with the linear range from 1 to 11 mM and a detection limit of 0.01 mM. Furthermore, the biosensor shows rapid response, high sensitivity, good reproducibility, long-term stability and freedom of interference from other co-existing electroactive species.  相似文献   

18.
Recent advances in graphene-based biosensors   总被引:1,自引:0,他引:1  
A detailed overview towards the advancement of graphene based biosensors has been reviewed. The large surface area and excellent electrical conductivity of graphene allow it to act as an "electron wire" between the redox centers of an enzyme or protein and an electrode's surface. Rapid electron transfer facilitates accurate and selective detection of biomolecules. This review discusses the application of graphene for the detection of glucose, Cyt-c, NADH, Hb, cholesterol, AA, UA, DA, and H(2)O(2). GO and RGO have been used for the fabrication of heavy metal ion sensors, gas sensors, and DNA sensors. Graphene based FETs have also been discussed in details. In all these cases, the biosensors performed well with low working potentials, high sensitivities, low detection limits, and long-term stabilities.  相似文献   

19.
Electrochemistry of microperoxidase-11 (MPx-11) anchored on the mixed self-assembled monolayer (SAM) of 2-(2-mercaptoethylpyrazine) (PET) and 4,4'-dithiodibutyric acid (DTB) on gold (Au) electrode and the biosensing of uric acid (UA) is described. MPx-11 has been covalently anchored on the mixed SAM of PET and DTB on Au electrode. MPx-11 on the mixed self-assembly exhibits reversible redox response characteristic of a surface confined species. The heterocyclic ring of PET promotes the electron transfer between the electrode and the redox protein. The apparent standard rate constant kapps obtained for the redox reaction of MPx-11 on the mixed monolayer is approximately 2.15 times higher than that on the single monolayer of DTB modified electrode. MPx-11 efficiently mediates the electrocatalytic reduction of H2O2. MPx-11 electrode is highly sensitive to H2O2 and it shows linear response for a wide concentration range. The electrocatalytic activity of the MPx-11 electrode is combined with the enzymatic activity of uricase (UOx) to fabricate uric acid biosensor. The bienzyme assembly is highly sensitive towards UA and it could detect UA as low as 2 microM at the potential of -0.1 V. The biosensor shows linear response with a sensitivity of 3.4+/-0.08 nA cm(-2) microM(-1). Ascorbate (AA) and paracetamol (PA) do not significantly interfere in the amperometric sensing of UA.  相似文献   

20.
Guo H  Ye C  He H  Chen Z  Hu J  Hu G  Li A 《Biosensors & bioelectronics》2012,33(1):204-210
Neodymium (Nd) substituted bismuth titanate (Bi(4-x)Nd(x)Ti(3)O(12), BNTO-x) nanoplates inlaid one another were prepared by sol-gel hydrothermal method, which was explored for protein immobilization and biosensor fabrication. Comparative experiments witnessed that Bi(3+) ions in bismuth titanate (Bi(4)Ti(3)O(12), BTO) were successfully substituted with Nd(3+) ions, and the electrochemical properties of the Hb-Chi-BNTO biosensors closely depended on the Nd(3+) ion content. With increasing the Nd(3+) doping content, the electrochemical performance of the Hb-Chi-BNTO-x biosensors showed regularly variable. Moreover, compared with the Hb-Chi-BTO and other Hb-Chi-BNTO-x biosensors, the Hb-Chi-BNTO-0.85 biosensor had more excellent electrochemical and electrocatalytic properties such as stronger redox peak currents (approximately three-fold), smaller peak-to-peak separation (50 mV), larger heterogeneous electron transfer rate (14.1 ± 3.8s(-1)), higher surface concentration of electroactive redox protein (about 8.16 × 10(-11)mol/cm(2)), and better reproducibility and stability. The Nd-depended electrochemical properties of the Hb-Chi-BNTO biosensors may open up a new idea for designing third-generation electrochemical biosensors, and the BNTO-0.85-based biosensor is also expected to find potential applications in many areas such as biomedical, food, and environmental detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号