首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
2.
BackgroundThe dosimetric characterization of volumetric modulated arc therapy (VMAT)-based total-body irradiation (TBI) in pediatric patients is evaluated.Materials and methodsTwenty-two patients between the ages of 2 and 12 years were enrolled for VMAT-based TBI from 2018 to 2020. Three isocenters were irradiated over three overlapping arcs. While prescribing 90% of the TBI dose to the planning treatment volume (PTV), two fractions (2 Gy each) were delivered each day; hence 12 Gy was delivered in six fractions. During treatment optimization, the mean lung and kidney doses were set not to exceed 7 Gy and 7.5 Gy, respectively. The maximum lens dose was also set to less than 4 Gy. Patient quality assurance was carried out by comparing treatment planning system doses to the 3-dimensional measured doses by the ArcCHECK® detector. The electronic portal imaging device (EPID) gamma indices were also obtained.ResultsThe average mean lung dose was 7.75 ± 0.18 Gy, mean kidney dose 7.63 ± 0.26 Gy, maximum lens dose 4.41 ± 0.39 Gy, and the mean PTV dose 12.69 ± 0.16 Gy. The average PTV heterogeneity index was 1.15 ± 0.03. Average differences in mean kidney dose, mean lung dose, and mean target dose were 2.79% ± 0.88, 0.84% ± 0.45 and 0.93% ± 0.47, respectively; when comparing planned and ArcCHECK® measured doses. Only grade 1–2 radiation toxicities were recorded, based on CTCAE v5.0 scoring criteria.ConclusionsVMAT-TBI was characterized with good PTV coverage, homogeneous dose distribution, planned and measured dose agreement, and low toxicity.  相似文献   

3.
BackgroundThis study presents a retrospective analysis (efficacy and toxicity) of outcomes in patients with unresectable recurrence of previously irradiated head and neck (H&N) cancers treated with proton therapy. Locoregional recurrence is the main pattern of failure in the treatment of H&N cancers. Proton re-irradiation in patients with relapse after prior radiotherapy might be valid as promising as a challenging treatment option.Materials and methodsFrom November 2015 to January 2020, 30 patients with in-field recurrence of head and neck cancer, who were not suitable for surgery due to medical contraindications, tumor localization, or extent, received re-irradiation with intensity-modulated proton therapy (IMPT). Sites of retreatment included the aerodigestive tract (60%) and the base of skull (40%). The median total dose of prior radiotherapy was 55.0 Gy. The median time to the second course was 38 months. The median re-irradiated tumor volume was 158.1 cm3. Patients were treated with 2.0, 2.4, and 3.0 GyRBE per fraction, with a median equivalent dose (EQD2) of 57.6 Gy (α/β = 10). Radiation-induced toxicity was recorded according to the RTOG/EORTC criteria.ResultsThe 1- and 2-year local control (LC), progression-free survival (PFS), and overall survival (OS) were 52.6/21.0, 21.9/10.9, and 73.4/8.4%, respectively, with a median follow-up time of 21 months. The median overall survival was 16 months. Acute grade 3 toxicity was observed in one patient (3.3%). There were five late severe side effects (16.6%), with one death associated with re-irradiation.ConclusionRe-irradiation with a proton beam can be considered a safe and efficient treatment even for a group of patients with unresectable recurrent H&N cancers.  相似文献   

4.

Aim

The purpose of this study was to evaluate acute and late toxicity and the locoregional control in patients treated with hypofractionated radical radiotherapy 2.25 Gy/fraction/day for early glottic carcinoma.

Materials and methods

A retrospective analysis was performed of 27 patients, stage T1–T2 N0 glottic squamous cell carcinoma, that underwent radical RT from April 2008 to October 2011. The mean age was 64.6 years (range 36–81). Seventeen patients were staged T1a, 3 patients T1b and 7 patients T2. All patients were 3D planned and treated in a 6 MV LINAC, 2.25 Gy/fraction/5 days per week, to a total dose between 63 Gy and 67.5 Gy. Biological Effective Dose (BED (α/β = 10)) ranged from 77.18 Gy to 82.69 Gy and EQD2 from 64.31 Gy to 68.91 Gy. Patients were evaluated in periodic follow-up. Toxicity was evaluated according to RTOG Toxicities Scales.

Results

With a median follow-time of 24.7 months (range 3.6–44.2 months), no evidence of locoregional recurrence was observed. The treatment was well tolerated and no unscheduled interruptions in treatments for toxicity were documented, with the median overall treatment time of 41 days (range 38–48). Only grades 1 and 2 acute toxicity were observed and no evidence of severe late toxicity.

Conclusion

The authors believe that this moderately hypofractionated scheme can provide a good locoregional control for T1–T2 glottic carcinomas with no increase of toxicity. As the limitation of this work is the reduced number of patients and the lack of long term follow-up, the authors hope to update this retrospective study in the future in order to improve the power of the results.  相似文献   

5.
Objectives:To investigate the effect of vagus nerve stimulation (VNS) on the bone mineral density (BMD) in epileptic patients.Methods:A prospective cohort study was conducted on individuals with refractory seizures who underwent VNS surgery between January 2012 and December 2018. BMD was measured preoperatively and between 6 months and one year after surgery.Results:Twenty-one patients (mean age (±SD)=23.6±12.3 years) were recruited for the implantation of a VNS device. The mean absolute increase in lumbar BMD in the 21 patients was 0.04±0.04 g/cm2 resulting in an overall percent increase from baseline of 4.7±6.1%. BMD increased by an amount ≥ the least significant change (LSC) for the lumbar spine in 13 patients (61.9%). The lumbar Z score also increased in these patients from -1.22±1.15 to -0.88±1.22, P=0.006). Pre and Post VNA femoral BMD was measured in only 11 patients and, of those 3 showed a significant increase in BMD, 1 a significant decrease and 7 no change.Conclusion:The implantation of a VNS was associated with an increase in lumbar BMD. This study could lead to a new application for VNS in the treatment of osteoporosis.  相似文献   

6.

Aim

This study evaluates the acute toxicity outcome in patients treated with RapidArc for localized prostate cancer.

Background

Modern technologies allow the delivery of high doses to the prostate while lowering the dose to the neighbouring organs at risk. Whether this dosimetric advantage translates into clinical benefit is not well known.

Materials and methods

Between December 2009 and May 2012, 45 patients with primary prostate adenocarcinoma were treated using RapidArc. All patients received 1.8 Gy per fraction, the median dose to the prostate gland, seminal vesicles, pelvic lymph nodes and surgical bed was 80 Gy (range, 77.4–81 Gy), 50.4 Gy, 50.4 Gy and 77.4 Gy (range, 75.6–79.2 Gy), respectively.

Results

The time between the last session and the last treatment follow up was a median of 10 months (range, 3–24 months). The incidence of grade 3 acute gastrointestinal (GI) and genitourinary (GU) toxicity was 2.2% and 15.5%, respectively. Grade 2 acute GI and GU toxicity occurred in 30% and 27% of patients, respectively. No grade 4 acute GI and GU toxicity were observed. Older patients (>median) or patients with V60 higher than 35% had significantly higher rates of grade ≥2 acute GI toxicity compared with the younger ones.

Conclusions

RapidArc in the treatment of localized prostate cancer is tolerated well with no Grade >3 GI and GU toxicities. Older patients or patients with higher V60 had significantly higher rates of grade ≥2 acute GI toxicity. Further research is necessary to assess definitive late toxicity and tumour control outcome.  相似文献   

7.

Aim

To compare and evaluate the performance of two different volumetric modulated arc therapy delivery techniques.

Background

Volumetric modulated arc therapy is a novel technique that has recently been made available for clinical use. Planning and dosimetric comparison study was done for Elekta VMAT and Varian RapidArc for different treatment sites.

Materials and methods

Ten patients were selected for the planning comparison study. This includes 2 head and neck, 2 oesophagus, 1 bladder, 3 cervix and 2 rectum cases. Total dose of 50 Gy was given for all the plans. All plans were done for RapidArc using Eclipse and for Elekta VMAT with Monaco treatment planning system. All plans were generated with 6 MV X-rays for both RapidArc and Elekta VMAT. Plans were evaluated based on the ability to meet the dose volume histogram, dose homogeneity index, radiation conformity index, estimated radiation delivery time, integral dose and monitor units needed to deliver the prescribed dose.

Results

RapidArc plans achieved the best conformity (CI95% = 1.08 ± 0.07) while Elekta VMAT plans were slightly inferior (CI95% = 1.10 ± 0.05). The in-homogeneity in the PTV was highest with Elekta VMAT with HI equal to 0.12 ± 0.02 Gy when compared to RapidArc with 0.08 ± 0.03. Significant changes were observed between the RapidArc and Elekta VMAT plans in terms of the healthy tissue mean dose and integral dose. Elekta VMAT plans show a reduction in the healthy tissue mean dose (6.92 ± 2.90) Gy when compared to RapidArc (7.83 ± 3.31) Gy. The integral dose is found to be inferior with Elekta VMAT (11.50 ± 6.49) × 104 Gy cm3 when compared to RapidArc (13.11 ± 7.52) × 104 Gy cm3. Both Varian RapidArc and Elekta VMAT respected the planning objective for all organs at risk. Gamma analysis result for the pre-treatment quality assurance shows good agreement between the planned and delivered fluence for 3 mm DTA, 3% DD for all the evaluated points inside the PTV, for both VMAT and RapidArc techniques.

Conclusion

The study concludes that a variable gantry speed with variable dose rate is important for efficient arc therapy delivery. RapidArc presents a slight improvement in the OAR sparing with better target coverage when compared to Elekta VMAT. Trivial differences were noted in all the plans for organ at risk but the two techniques provided satisfactory conformal avoidance and conformation.  相似文献   

8.
9.

Introduction

The advent of electroanatomical mapping (EAM) systems for pulmonary vein isolation (PVI) has dramatically decreased radiation exposure. However, the need for some fluoroscopy remains for obtaining left atrial (LA) access. The aim was to test the feasibility of fluoroscopy-free PVI in patients with atrial fibrillation (AF) and a patent foramen ovale (PFO) guided solely by an EAM system.

Methods

Consecutive patients with AF undergoing PVI and documented PFO were studied. An EAM-guided approach without fluoroscopy and ultrasound was used. After completing the map of the right atrium, the superior vena cava and the coronary sinus, a catheter pull-down to the PFO was performed allowing LA access. The map of the LA and subsequent PVI was also performed without fluoroscopy.

Results

30 patients [age 61±12 years, 73% male, ejection fraction 0.64 (0.53–0.65), LA size in parasternal long axis 38±7 mm] undergoing PVI were included. The time required for right atrial mapping including transseptal crossing was 9±4 minutes. Total procedure time was 127±37 minutes. Fluoroscopy-free PVI was feasible in 26/30 (87%) patients. In four patients, fluoroscopy was needed to access (n = 3) or to re-access (n = 1) the LA. In these four patients, total fluoroscopy time was 5±3 min and the DAP was 14.9±13.4 Gy*cm2. Single-procedure success rate was 80% (24/30) after a median follow-up of 12 months.

Conclusion

In patients with a documented PFO, completely fluoroscopy-free PVI is feasible in the vast majority of cases.  相似文献   

10.

Objectives

Cardiovascular magnetic resonance feature tracking (CMR-FT) offers quantification of myocardial deformation from routine cine images. However, data using CMR-FT to quantify left ventricular (LV) torsion and diastolic recoil are not yet available. We therefore sought to evaluate the feasibility and reproducibility of CMR-FT to quantify LV torsion and peak recoil rate using an optimal anatomical approach.

Methods

Short-axis cine stacks were acquired at rest and during dobutamine stimulation (10 and 20 µg·kg−1·min−1) in 10 healthy volunteers. Rotational displacement was analysed for all slices. A complete 3D-LV rotational model was developed using linear interpolation between adjacent slices. Torsion was defined as the difference between apical and basal rotation, divided by slice distance. Depending on the distance between the most apical (defined as 0% LV distance) and basal (defined as 100% LV distance) slices, four different models for the calculation of torsion were examined: Model-1 (25–75%), Model-2 (0–100%), Model-3 (25–100%) and Model-4 (0–75%). Analysis included subendocardial, subepicardial and global torsion and recoil rate (mean of subendocardial and subepicardial values).

Results

Quantification of torsion and recoil rate was feasible in all subjects. There was no significant difference between the different models at rest. However, only Model-1 (25–75%) discriminated between rest and stress (Global Torsion: 2.7±1.5°cm−1, 3.6±2.0°cm−1, 5.1±2.2°cm−1, p<0.01; Global Recoil Rate: −30.1±11.1°cm−1s−1,−46.9±15.0°cm−1s−1,−68.9±32.3°cm−1s−1, p<0.01; for rest, 10 and 20 µg·kg−1·min−1 of dobutamine, respectively). Reproducibility was sufficient for all parameters as determined by Bland-Altman analysis, intraclass correlation coefficients and coefficient of variation.

Conclusions

CMR-FT based derivation of myocardial torsion and recoil rate is feasible and reproducible at rest and with dobutamine stress. Using an optimal anatomical approach measuring rotation at 25% and 75% apical and basal LV locations allows effective quantification of torsion and recoil dynamics. Application of these new measures of deformation by CMR-FT should next be explored in disease states.  相似文献   

11.
BackgroundThe purpose of the study was to evaluate the toxicity and outcome of nasopharyngeal carcinoma patients treated using 3-dimensional conformal radiotherapy (3DCRT) or volumetric modulated arc therapy (VMAT) technique.Materials and methods68 patients treated between 2006 and 2018 were retrospectively analysed. Since 2009 patients received 3DCRT with 50/70 Gy to the elective/boost volumes in 35 fractions; from then, VMAT with simultaneous integrated boost (SIB) with 54.45/69.96 Gy in 33, or 54/66 Gy in 30 fractions. Induction chemotherapy was administered in 74% of the patients, concomitant cisplatinum in 87%. Acute and late toxicity data, progression-free survival PSF and overall survival OS, and toxicity correlations with dose metrics were reported.ResultsWith a median follow-up of 64 months, complete remission at the last evaluation was in 68% of the patients, while 28% and 9% had locoregional relapse and distant disease, respectively. The 5- and 10-year progression free survival (PFS) rates were 62.7 ± 6.5% and 53.2 ± 8.7%, respectively. The 5- and 10-year OS rates were 78.9 ± 5.5% and 61.4 ± 9.2%, respectively. At the multivariate Cox analysis TNM stage (p = 0.02) and concomitant chemotherapy (p = 0.01) resulted significant for PFS, concomitant chemotherapy (p = 0.04) for OS.Improvements in acute toxicity were presented for VMAT patients due to its ability to spare OARs. Odds ratio (OR) for acute salivary toxicity, between VMAT and 3DCRT, was 4.67 (p = 0.02). Dosimetrically, salivary toxicity correlated with mean parotid dose (p = 0.05), dysphagia with laryngeal (p = 0.04) and mean oral cavity (p = 0.06) doses, when dose-volume histograms (DVHs) are corrected for fractionation.ConclusionThis study is a proof of a significant benefit of the VMAT technique compared with 3DCRT in terms of side effects in nasopharynx patients, and adds dosimetric correlations.  相似文献   

12.
AimsWe investigated whether sprint interval training (SIT) was a time-efficient exercise strategy to improve insulin sensitivity and other indices of cardiometabolic health to the same extent as traditional moderate-intensity continuous training (MICT). SIT involved 1 minute of intense exercise within a 10-minute time commitment, whereas MICT involved 50 minutes of continuous exercise per session.MethodsSedentary men (27±8y; BMI = 26±6kg/m2) performed three weekly sessions of SIT (n = 9) or MICT (n = 10) for 12 weeks or served as non-training controls (n = 6). SIT involved 3x20-second ‘all-out’ cycle sprints (~500W) interspersed with 2 minutes of cycling at 50W, whereas MICT involved 45 minutes of continuous cycling at ~70% maximal heart rate (~110W). Both protocols involved a 2-minute warm-up and 3-minute cool-down at 50W.ResultsPeak oxygen uptake increased after training by 19% in both groups (SIT: 32±7 to 38±8; MICT: 34±6 to 40±8ml/kg/min; p<0.001 for both). Insulin sensitivity index (CSI), determined by intravenous glucose tolerance tests performed before and 72 hours after training, increased similarly after SIT (4.9±2.5 to 7.5±4.7, p = 0.002) and MICT (5.0±3.3 to 6.7±5.0 x 10−4 min-1 [μU/mL]-1, p = 0.013) (p<0.05). Skeletal muscle mitochondrial content also increased similarly after SIT and MICT, as primarily reflected by the maximal activity of citrate synthase (CS; P<0.001). The corresponding changes in the control group were small for VO2peak (p = 0.99), CSI (p = 0.63) and CS (p = 0.97).ConclusionsTwelve weeks of brief intense interval exercise improved indices of cardiometabolic health to the same extent as traditional endurance training in sedentary men, despite a five-fold lower exercise volume and time commitment.  相似文献   

13.
Magnesium ions strongly influence the structure and biochemical activity of RNA. The interaction of Mg2+ with an equimolar mixture of poly(rA) and poly(rU) has been investigated by UV spectroscopy, isothermal titration calorimetry, ultrasound velocimetry and densimetry. Measurements in dilute aqueous solutions at 20°C revealed two differ ent processes: (i) Mg2+ binding to unfolded poly(rA)·poly(rU) up to [Mg2+]/[phosphate] = 0.25; and (ii) poly(rA)·2poly(rU) triplex formation at [Mg2+]/[phosphate] between 0.25 and 0.5. The enthalpies of these two different processes are favorable and similar to each other, ~–1.6 kcal mol–1 of base pairs. Volume and compressibility effects of the first process are positive, 8 cm3 mol–1 and 24 × 10–4 cm3 mol–1 bar–1, respectively, and correspond to the release of water molecules from the hydration shells of Mg2+ and the polynucleotides. The triplex formation is also accompanied by a positive change in compressibility, 14 × 10–4 cm3 mol–1 bar–1, but only a small change in volume, 1 cm3 mol–1. A phase diagram has been constructed from the melting experiments of poly(rA)·poly(rU) at a constant K+ concentration, 140 mM, and various amounts of Mg2+. Three discrete regions were observed, corresponding to single-, double- and triple-stranded complexes. The phase boundary corresponding to the transition between double and triple helical conformations lies near physiological salt concentrations and temperature.  相似文献   

14.
BackgroundThe purpose of this study was to compare four 3D conformal radiation techniques in treatment of left breast cancer patients.Materials and methodsRadiation was planned for 20 patients to the left breast and regional lymph nodes using four techniques: partially wide tangents, photon-photon mix, photon-electron mix and 30/70 photon-electron mix. All plans were evaluated for internal mammary nodes (IMN) coverage, hotspot and normal tissue constraints.ResultThe 85% of planning target volume (PTV) coverage was lesser for upper IMN than the lower IMN (below the lower border of the clavicular head) for all four techniques. The lower IMN coverage was better for partially wide tangent (80.46%) and photon-photon mix (88.88%). The lowest value of hotspot was seen in the partially wide tangent technique (112.69% ± 1.92). Hotspot is unacceptably high in both photon-electron mix and 30/70 photon-electron mix (> 120%). Left lung mean dose for all techniques on a pair-wise comparison showed no statistical difference. Left lung V20 values for partially wide tangent was 37.56% ± 8.17 and for photon-photon mix it was 40.49% ± 3.36. The mean heart dose with partially wide tangent was 9.43 ± 3.15 Gy and with photon-photon mix it was 10.10 ± 2.70 Gy. The mean heart dose for photon-electron mix was 7.56 ± 1.95 Gy and for 30/70 photon-electron mix it was 7.98 ± 2.16 Gy.ConclusionNo single technique satisfies all the criteria. The decision should be made on a case-by-case basis, considering the anatomy of the patient, availability of electron facilities and setup accuracy and reproducibility.  相似文献   

15.

Background

Pericardial fluid (PF) contains several biologically active substances, which may provide information regarding the cardiac conditions. Nitric oxide (NO) has been implicated in cardiac remodeling. We hypothesized that L-arginine (L-Arg) precursor of NO-synthase (NOS) and asymmetric dimethylarginine (ADMA), an inhibitor of NOS, are present in PF of cardiac patients and their altered levels may contribute to altered cardiac morphology.

Methods

L-Arg and ADMA concentrations in plasma and PF, and echocardiographic parameters of patients undergoing coronary artery bypass graft (CABG, n = 28) or valve replacement (VR, n = 25) were determined.

Results

We have found LV hypertrophy in 35.7% of CABG, and 80% of VR patients. In all groups, plasma and PF L-Arg levels were higher than that of ADMA. Plasma L-Arg level was higher in CABG than VR (75.7±4.6 μmol/L vs. 58.1±4.9 μmol/L, p = 0.011), whereas PF ADMA level was higher in VR than CABG (0.9±0.0 μmol/L vs. 0.7±0.0 μmol/L, p = 0.009). L-Arg/ADMA ratio was lower in the VR than CABG (VRplasma: 76.1±6.6 vs. CABGplasma: 125.4±10.7, p = 0.004; VRPF: 81.7±4.8 vs. CABGPF: 110.4±7.2, p = 0.009). There was a positive correlation between plasma L-Arg and ADMA in CABG (r = 0.539, p = 0.015); and plasma and PF L-Arg in CABG (r = 0.357, p = 0.031); and plasma and PF ADMA in VR (r = 0.529, p = 0.003); and PF L-Arg and ADMA in both CABG and VR (CABG: r = 0.468, p = 0.006; VR: r = 0.371, p = 0.034). The following echocardiographic parameters were higher in VR compared to CABG: interventricular septum (14.7±0.5 mm vs. 11.9±0.4 mm, p = 0.000); posterior wall thickness (12.6±0.3 mm vs. 11.5±0.2 mm, p = 0.000); left ventricular (LV) mass (318.6±23.5 g vs. 234.6±12.3 g, p = 0.007); right ventricular (RV) (33.9±0.9 cm2 vs. 29.7±0.7 cm2, p = 0.004); right atrial (18.6±1.0 cm2 vs. 15.4±0.6 cm2, p = 0.020); left atrial (19.8±1.0 cm2 vs. 16.9±0.6 cm2, p = 0.033) areas. There was a positive correlation between plasma ADMA and RV area (r = 0.453, p = 0.011); PF ADMA and end-diastolic (r = 0.434, p = 0.015) and systolic diameter of LV (r = 0.487, p = 0.007); and negative correlation between PF ADMA and LV ejection fraction (r = -0.445, p = 0.013) in VR.

Conclusion

We suggest that elevated levels of ADMA in the PF of patients indicate upregulated RAS and reduced bioavailability of NO, which can contribute to the development of cardiac hypertrophy and remodeling.  相似文献   

16.
We used a combination of 15N tracer methods and a C2H2 blockage technique to determine the role of sediment nitrification and denitrification in a deep oligotrophic arctic lake. Inorganic nitrogen concentrations ranged between 40 and 600 nmol · cm−3, increasing with depth below the sediment-water interface. Nitrate concentrations were at least 10 times lower, and nitrate was only detectable within the top 0 to 6 cm of sediment. Eh and pH profiles showed an oxidized surface zone underlain by more reduced conditions. The lake water never became anoxic. Sediment Eh values ranged from −7 to 484 mV, decreasing with depth, whereas pH ranged from 6.0 to 7.3, usually increasing with depth. The average nitrification rate (49 ng of N · cm−3 · day−1) was similar to the average denitrification rate (44 ng of N · cm−3 · day−1). In situ N2O production from nitrification and denitrification ranged from 0 to 25 ng of N · cm−3 · day−1. Denitrification appears to depend on the supply of nitrate by nitrification, such that the two processes are coupled functionally in this sediment system. However, the low rates result in only a small nitrogen loss.  相似文献   

17.
BackgroundThe purpose of this study was to investigate the feasibility of MOSFET dosimeter in measuring eye dose during 2D MV portal imaging for setup verification in radiotherapy.Materials and methodsThe in-vivo dose measurements were performed by placing the dosimeters over the eyes of 30 brain patients during the acquisition of portal images in linear accelerator by delivering 1 MU with the field sizes of 10 × 10 cm2 and 15 × 15 cm2.ResultsThe mean doses received by the left and right eyes of 10 out of 30 patients when both eyes were completely inside the anterior portal field were found to be 2.56 ± 0.2 cGy and 2.75 ± 0.2, respectively. Similarly, for next 10 patients out of the same 30 patients the mean doses to left and right eyes when both eyes were completely out of the anterior portal fields were found to be 0.13 ± 0.02 cGy and 0.17 ± 0.02 cGy, respectively. The mean doses to ipsilateral and contralateral eye for the last 10 patients when one eye was inside the anterior portal field were found to be 3.28 ± 0.2 cGy and 0.36 ± 0.1 cGy, respectively.ConclusionThe promising results obtained during 2D MV portal imaging using MOSFET have shown that this dosimeter is well suitable for assessing low doses during imaging thereby enabling to optimize the imaging procedure using the dosimetric data obtained. In addition, the documentation of the dose received by the patient during imaging procedure is possible with the help of an in-built software in conjunction with the MOSFET reader module.  相似文献   

18.
AimTo analyse the possible relationship between the EQD2(α/β=3Gy) at 2 cm3 of the vagina and late toxicity in vaginal-cuff-brachytherapy (VBT) after external-beam-irradiation (EBRT) for postoperative endometrial carcinoma (EC).Materials and methodsFrom 2014 to 2016, 62 postoperative EC patients were treated with EBRT + VBT. The median EBRT dose was 45 Gy (44 Gy–50.4 Gy). VBT involved a single 7 Gy dose. Toxicity was prospectively evaluated using the RTOG score for the rectum and bladder and the objective LENT-SOMA criteria for the vagina. EQD2(α/β = 3Gy) at 2 cm3 of the most exposed part of the vagina was calculated by the sum of the EBRT + VBT dose. Statistics: Boxplot, Student’s t and Chi-square tests and ROC curves.ResultsMean follow-up: 39.2 months (15–68). Late toxicity: bladder:0 patient; rectum:2 patients-G1; Vagina: 26 patients-17G1, 9G2; median EQD2(α/β=3Gy) at 2 cm3 in G0-G1 patients was 70.4 Gy(SD2.36), being 72.5 Gy(SD2.94) for G2p. The boxplot suggested a cut-point identifying the absence of G2: 100 % of G2p received >68 Gy, ROC curves showed an area under the curve of 0.72 (sensitivity of 1 and specificity of 0.15).ConclusionsDoses >68 Gy EQD2(α/β=3Gy) at 2 cm3 to the most exposed area of the vagina were associated with late G2 vaginal toxicity in postoperative EC patients treated with EBRT + VBT suggesting a very good dose limit to eliminate the risk of G2 late toxicity. The specificity obtained indicates the need for prospective analyses.  相似文献   

19.
Physicochemical and Light Scattering Studies on Ribosome Particles   总被引:2,自引:0,他引:2       下载免费PDF全文
The light scattering technique has been used to measure the molecular weight of Escherichia coli ribosomes. The 30S, 50S, and 70S components have been isolated and purified. The refractive index increment dn/dc was found to have the same value, (0.20 ±0.01) cm3/g, for the three species. The molecular weights are (1.0 ±0.1)·106, (1.7 ±0.1)·106, and (2.9 ±0.3)·106 daltons respectively. Some information about the dimensions in solution (radius of gyration) and the interaction constant (second virial coefficient) have been obtained, and their significance is discussed.  相似文献   

20.
To consider the effect of surface microvilli on measurements of lateral diffusion by fluorescence photobleaching recovery, we have measured the diffusion of the lipid probe 3,3′-dihexadecyl indocarbocyanine iodide on the villated main body and unvillated budding polar body of unfertilized mouse eggs. On the main body we found D = (6.41 ± 0.62) × 10-9 cm2/s with (77.0 ± 2.1)% recovery, and on the budding polar body we found D = (7.05 ± 0.75) × 10-9 cm2/s with (84.7 ± 1.3)% recovery. We thus find only slight differences in diffusion in the two regions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号