首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
Markerless motion capture systems have developed in an effort to evaluate human movement in a natural setting. However, the accuracy and reliability of these systems remain understudied. Therefore, the goals of this study were to quantify the accuracy and repeatability of joint angles using a single camera markerless motion capture system and to compare the markerless system performance with that of a marker-based system. A jig was placed in multiple static postures with marker trajectories collected using a ten camera motion analysis system. Depth and color image data were simultaneously collected from a single Microsoft Kinect camera, which was subsequently used to calculate virtual marker trajectories. A digital inclinometer provided a measure of ground-truth for sagittal and frontal plane joint angles. Joint angles were calculated with marker data from both motion capture systems using successive body-fixed rotations. The sagittal and frontal plane joint angles calculated from the marker-based and markerless system agreed with inclinometer measurements by <0.5°. The systems agreed with each other by <0.5° for sagittal and frontal plane joint angles and <2° for transverse plane rotation. Both systems showed a coefficient of reliability <0.5° for all angles. These results illustrate the feasibility of a single camera markerless motion capture system to accurately measure lower extremity kinematics and provide a first step in using this technology to discern clinically relevant differences in the joint kinematics of patient populations.  相似文献   

2.
Several investigators have suggested the presence of a link between Chronic Low Back Pain (CLBP) and lower limbs kinematics that can contribute to functional limitations and disability. Moreover, CLBP has been connected to postural and structural asymmetry. Understanding the movement pattern of lower extremities and its asymmetry during walking can provide a basis for examination and rehabilitation in people with CLBP. The present study focuses on lower limbs kinematics in individuals with CLBP during walking. Three-dimensional movements of the pelvic, hip, knee and ankle joints were tracked using a seven-camera Qualysis motion capture system. Functional dada analysis (FDA) was applied for the statistical analysis of pelvic and lower limbs motion patterns in 40 participants (20 CLBP and 20 controls). The CLBP group showed significantly different hip motion pattern in the transvers plane, altered knee and ankle motion pattern in the sagittal plane on the dominant side and different hip motion pattern in the transvers and frontal planes on the non-dominant side in comparison with the control group over the stance phase. In terms of symmetry, in the CLBP group, hip and knee moved through a significantly different motion patterns in the transvers plane on the dominant side in comparison with the non-dominant side. In the control group, knee moved through a significantly different motion pattern in the transvers plane on the dominant side in comparison with the non-dominant side. In conclusion, low back pain lead to altered movement patterns of the main joints of lower limbs especially on the dominant side during stance phase. Therefore, care should be taken to examine dominant lower limb movement pattern in CLBP to make a better clinical decision.  相似文献   

3.
1. (1) Two small, basic peptides (Ic and II) which stimulate muscles of the hindgut, but not the heart, have been separated from extracts of the corpora cardiaca by ion exchange chromatography and gel filtration.
2. (2) Results obtained with the 5-HT antagonist mianserin hydrochloride suggest that both peptides stimulate contractions of the hindgut by direct action without mediation by an indoleamine such as 5-HT.
3. (3) Extracellular calcium ions are required for rapid contractions of the hindgut stimulated by peptides Ic and II. However, the tonus response to these peptides does not appear to depend on the same inward transmembrane transport of extracellular Ca2+ as rapid contractions.
4. (4) Theophylline (5 mM) potentiated the action of both peptides on hindgut muscle, however, stimulation of hindgut muscle by cardiacal extract did not cause a significant increase in the level of cyclic AMP as compared with controls.
5. (5) These results more clearly define the number, character and possible action of cardiacal peptides stimulating hindgut muscle in P. americana.
  相似文献   

4.
Accurate location of the hip joint center is essential for computation of hip kinematics and kinetics as well as for determination of the moment arms of muscles crossing the hip. The functional method of hip joint center location involves fitting a pelvis-fixed sphere to the path traced by a thigh-fixed point while a subject performs hip motions; the center of this sphere is the hip joint center. The aim of the present study was to evaluate the potential accuracy of the functional method and the dependence of its accuracy on variations in its implementation and the amount of available hip motion. The motions of a mechanical linkage were studied to isolate the factors of interest, removing errors due to skin movement and the palpation of bony landmarks that are always present in human studies. It was found that reducing the range of hip motion from 30 degrees to 15 degrees did significantly increase hip joint center location errors, but that restricting motion to a single plane did not. The magnitudes of these errors, however, even in the least accurate cases, were smaller than those previously reported for either the functional method or other methods based on pelvis measurements of living subjects and cadaver specimens. Neither increasing the number of motion data observations nor analyzing the motion of a single thigh marker (rather than the centroid of multiple markers) was found to significantly increase error. The results of this study (1) imply that the limited range of motion that is often evident in subjects with hip pathology does not preclude accurate determination of the hip joint center when the functional method is used; and (2) provide guidelines for the use of the functional method in human subjects.  相似文献   

5.
6.
Skin-mounted marker based motion capture systems are widely used in measuring the movement of human joints. Kinematic measurements associated with skin-mounted markers are subject to soft tissue artifacts (STA), since the markers follow skin movement, thus generating errors when used to represent motions of underlying bone segments. We present a novel ultrasound tracking system that is capable of directly measuring tibial and femoral bone surfaces during dynamic motions, and subsequently measuring six-degree-of-freedom (6-DOF) tibiofemoral kinematics. The aim of this study is to quantitatively compare the accuracy of tibiofemoral kinematics estimated by the ultrasound tracking system and by a conventional skin-mounted marker based motion capture system in a cadaveric experimental scenario. Two typical tibiofemoral joint models (spherical and hinge models) were used to derive relevant kinematic outcomes. Intra-cortical bone pins equipped with optical markers were inserted in the tibial and femoral bones to serve as a reference to provide ground truth kinematics. The ultrasound tracking system resulted in lower kinematic errors than the skin-mounted markers (the ultrasound tracking system: maximum root-mean-square (RMS) error 3.44° for rotations and 4.88 mm for translations, skin-mounted markers with the spherical joint model: 6.32° and 6.26 mm, the hinge model: 6.38° and 6.52 mm). Our proposed ultrasound tracking system has the potential of measuring direct bone kinematics, thereby mitigating the influence and propagation of STA. Consequently, this technique could be considered as an alternative method for measuring 6-DOF tibiofemoral kinematics, which may be adopted in gait analysis and clinical practice.  相似文献   

7.
Widespread use of gait or motion analysis in the diagnosis of patients with locomotor pathology and the subsequent planning and assessment of treatment has been limited because of its reliability, particularly in evaluating frontal and transverse plane components. This is because spatial reconstruction of the musculoskeletal system and calculation of its kinematics and kinetics via a skin marker-based multi-link model are subject to marker skin movement artefacts. Traditional methods treat each body segment separately without imposing joint constraints, resulting in apparent dislocations at joints predominantly because of skin movement artefacts. An optimisation method for the determination of the positions and orientations of multi-link musculoskeletal models from marker co-ordinates is presented. It is based on the minimisation of the weighted sum of squared distances between measured and model-determined marker positions. The model imposes joint constraints. Numerical experiments were performed to show that the new method is capable of eliminating joint dislocations and giving more accurate model position and orientation estimations. It is suggested that, with joint constraints and a global error compensation scheme, the effects of measurement errors on the reconstruction of the musculoskeletal system and subsequent mechanical analyses can be reduced globally. The proposed method minimises errors in axial rotation and ab/adduction at the joints and may extend the applicability of gait analysis to clinical problems.  相似文献   

8.
Although alterations in knee joint loading resulting from injury have been shown to influence the development of osteoarthritis, actual in vivo loading conditions of the joint remain unknown. A method for determining in vivo ligament loads by reproducing joint specific in vivo kinematics using a robotic testing apparatus is described. The in vivo kinematics of the ovine stifle joint during walking were measured with 3D optical motion analysis using markers rigidly affixed to the tibia and femur. An additional independent single degree of freedom measuring device was also used to record a measure of motion. Following sacrifice, the joint was mounted in a robotic/universal force sensor test apparatus and referenced using a coordinate measuring machine. A parallel robot configuration was chosen over the conventional serial manipulator because of its greater accuracy and stiffness. Median normal gait kinematics were applied to the joint and the resulting accuracy compared. The mean error in reproduction as determined by the motion analysis system varied between 0.06 mm and 0.67 mm and 0.07 deg and 0.74 deg for the two individual tests. The mean error measured by the independent device was found to be 0.07 mm and 0.83 mm for the two experiments, respectively. This study demonstrates the ability of this system to reproduce in vivo kinematics of the ovine stifle joint in vitro. The importance of system stiffness is discussed to ensure accurate reproduction of joint motion.  相似文献   

9.
Scapula motion is significant for support of the arm and stability of the shoulder. The effect of the humeral elevation on scapular kinematics has been well investigated for normal subjects, but there are limited published studies investigating adaptations after shoulder arthroplasty. Scapula kinematics was measured on 10 shoulders (eight subjects) with a reverse total joint replacement. The measurements were performed using an instrumented palpating technique. Every subject performed three simple tasks: abduction, elevation in scapula plane and forward flexion. Results indicate that, lateral scapula rotation was significantly increased (average of 24.42% over the normal rhythm) but the change was variable. Despite the variability, there is a clear trend correlating humeral performance with increased rotation (R2 0.829). There is clearly an adaptation in lateral scapula rotation in patients with shoulder joint replacement. The reason for this is unclear and may be related to joint pathology or to muscle adaptation following arthroplasty.  相似文献   

10.

Background  

A sit-to-stand (STS) movement requires muscle strength higher than that of other daily activities. There are many elderly people, who experience difficulty when standing up from a chair. The muscle strength required (or the load on the joints) during a STS task is determined by the kinematics (movement pattern). The purpose of this study was to evaluate the kinematics and resultant joint moments of people standing up from a chair in order to determine the minimum peak joint moments required for a STS task.  相似文献   

11.
The movement of the knee joint consists of a coupled motion between the tibiofemoral and patellofemoral articulations. This study measured the six degrees-of-freedom kinematics of the tibia, femur, and patella using dual-orthogonal fluoroscopy and magnetic resonance imaging. Ten normal knees from ten living subjects were investigated during weightbearing flexion from full extension to maximum flexion. The femoral and the patellar motions were measured relative to the tibia. The femur externally rotated by 12.9 deg and the patella tilted laterally by 16.3 deg during the full range of knee flexion. Knee flexion was strongly correlated with patellar flexion (R(2)=0.91), posterior femoral translation was strongly correlated to the posterior patellar translation (R(2)=0.87), and internal-external rotation of the femur was correlated to patellar tilt (R(2)=0.73) and medial-lateral patellar translation (R(2)=0.63). These data quantitatively indicate a kinematic coupling between the tibia, femur, and patella, and provide base line information on normal knee joint kinematics throughout the full range of weightbearing flexion. The data also suggest that the kinematic coupling of tibia, femur, and patella should be considered when investigating patellar pathologies and when developing surgical techniques to treat knee joint diseases.  相似文献   

12.
Upper extremity musculoskeletal disorders represent an important health issue across all industry sectors; as such, the need exists to develop models of the hand that provide comprehensive biomechanics during occupational tasks. Previous optical motion capture studies used a single marker on the dorsal aspect of finger joints, allowing calculation of one and two degree-of-freedom (DOF) joint angles; additional algorithms were needed to define joint centers and the palmar surface of fingers. We developed a 6DOF model (6DHand) to obtain unconstrained kinematics of finger segments, modeled as frusta of right circular cones that approximate the palmar surface. To evaluate kinematic performance, twenty subjects gripped a cylindrical handle as a surrogate for a powered hand tool. We hypothesized that accessory motions (metacarpophalangeal pronation/supination; proximal and distal interphalangeal radial/ulnar deviation and pronation/supination; all joint translations) would be small (less than 5° rotations, less than 2mm translations) if segment anatomical reference frames were aligned correctly, and skin movement artifacts were negligible. For the gripping task, 93 of 112 accessory motions were small by our definition, suggesting this 6DOF approach appropriately models joints of the fingers. Metacarpophalangeal supination was larger than expected (approximately 10°), and may be adjusted through local reference frame optimization procedures previously developed for knee kinematics in gait analysis. Proximal translations at the metacarpophalangeal joints (approximately 10mm) were explained by skin movement across the metacarpals, but would not corrupt inverse dynamics calculated for the phalanges. We assessed performance in this study; a more rigorous validation would likely require medical imaging.  相似文献   

13.
14.
If the efficiency of human movement patterns could be improved using exercise, this could lead to more effective musculoskeletal disease-injury prevention and rehabilitation programs. It has been suggested that an efficient squat movement pattern emphasizes the use of the large hip extensors instead of the smaller knee extensors. The purpose of this study was to determine whether a counterbalanced squat (CBS) could produce a more hip-dominant and less knee-dominant squat movement pattern as compared with a regular squat (RS). There were 31 recreationally trained college-aged participants (15 male, 16 female) who performed 10 squats (5 CBS and 5 RS), while segment kinematics, ground reaction forces, and muscle (gluteus maximus [GM], quadriceps, hamstrings) electromyographic (EMG) activations were recorded. Peak sagittal plane net joint moments and joint ranges of motion at the hip, knee, and ankle joints along with peak and integrated EMG activation levels for all 3 muscles were compared using analysis of variance (squat type × sex). The results revealed that the CBS increased the hip joint moment and GM activation, while it decreased the knee joint moment and quadriceps activation as compared with the RS. Therefore, the CBS produces a more hip-dominant and less knee-dominant squat movement pattern and could be used in exercise programs aimed at producing more hip-dominant movement patterns.  相似文献   

15.
The complexity of shoulder mechanics combined with the movement of skin relative to the scapula makes it difficult to measure shoulder kinematics with sufficient accuracy to distinguish between symptomatic and asymptomatic individuals. Multibody skeletal models can improve motion capture accuracy by reducing the space of possible joint movements, and models are used widely to improve measurement of lower limb kinematics. In this study, we developed a rigid-body model of a scapulothoracic joint to describe the kinematics of the scapula relative to the thorax. This model describes scapular kinematics with four degrees of freedom: 1) elevation and 2) abduction of the scapula on an ellipsoidal thoracic surface, 3) upward rotation of the scapula normal to the thoracic surface, and 4) internal rotation of the scapula to lift the medial border of the scapula off the surface of the thorax. The surface dimensions and joint axes can be customized to match an individual’s anthropometry. We compared the model to “gold standard” bone-pin kinematics collected during three shoulder tasks and found modeled scapular kinematics to be accurate to within 2mm root-mean-squared error for individual bone-pin markers across all markers and movement tasks. As an additional test, we added random and systematic noise to the bone-pin marker data and found that the model reduced kinematic variability due to noise by 65% compared to Euler angles computed without the model. Our scapulothoracic joint model can be used for inverse and forward dynamics analyses and to compute joint reaction loads. The computational performance of the scapulothoracic joint model is well suited for real-time applications; it is freely available for use with OpenSim 3.2, and is customizable and usable with other OpenSim models.  相似文献   

16.
The purpose of this paper was to describe a technique that enables three-dimensional (3D) gait kinematics to be obtained using an electromagnetic tracking system, and to report the intra-trial, intra-day/inter-tester and inter-day/intra-tester repeatability of kinematic gait data obtained using this technique. Ten able-bodied adults underwent four gait assessments; the same two testers tested each subject independently on two different days. Gait assessments were conducted on a custom-built long-bed treadmill with no metal components between the rollers. Each gait assessment involved familiarisation to treadmill walking, subject anatomical and functional calibration, and a period of steady-state treadmill walking at a self-selected speed. Following data collection, 3D joint kinematics were calculated using the joint coordinate system approach. 3D joint angle waveforms for 10 left and right strides were extracted and temporally normalised for each trial. Intra-trial, intra-day/inter-tester and inter-day/intra-tester repeatability of the temporally normalised kinematic waveforms were quantified using the coefficient of multiple determination (CMD). CMDs for joint kinematics averaged 0.942 intra-trial, 0.849 intra-day/inter-tester and 0.773 inter-day/intra-tester. In general, sagittal plane kinematics were more repeatable than frontal or transverse plane kinematics, and kinematics at the hip were more repeatable than at the knee or ankle. The level of repeatability of kinematic gait data obtained during treadmill walking using this protocol was equal or superior to that reported previously for overground walking using image-based protocols.  相似文献   

17.
An optimal simulation 3D model for full-body upright reaching movements was developed using graphic-based modelling tools (SimMechanics) to generate an inverse dynamics model of the skeleton and using parameterisation methods for a sensory motor controller. The adaptive weight coefficient of the cost function based on the final motor task error (i.e. distance between end-effector and target at the end of movement) was used to correct motor task error and physiological measurements (e.g. joint power, centre of mass displacement, etc.). The output of the simulation models using various cost functions were compared to experimental data from 15 healthy participants performing full-body upright reaching movements. The proposed method can reasonably predict full-body voluntary movements in terms of final posture, joint power, and movement of the centre of mass (COM) using simple algebraic calculations of inverse dynamics and forward kinematics instead of the complicated integrals of the forward dynamics. We found that the combination of several control strategies, i.e. minimising end-effector error, total joint power and body COM produced the best fit of the full-body reaching task.  相似文献   

18.
Dynamic assessment of three-dimensional (3D) skeletal kinematics is essential for understanding normal joint function as well as the effects of injury or disease. This paper presents a novel technique for measuring in-vivo skeletal kinematics that combines data collected from high-speed biplane radiography and static computed tomography (CT). The goals of the present study were to demonstrate that highly precise measurements can be obtained during dynamic movement studies employing high frame-rate biplane video-radiography, to develop a method for expressing joint kinematics in an anatomically relevant coordinate system and to demonstrate the application of this technique by calculating canine tibio-femoral kinematics during dynamic motion. The method consists of four components: the generation and acquisition of high frame rate biplane radiographs, identification and 3D tracking of implanted bone markers, CT-based coordinate system determination, and kinematic analysis routines for determining joint motion in anatomically based coordinates. Results from dynamic tracking of markers inserted in a phantom object showed the system bias was insignificant (-0.02 mm). The average precision in tracking implanted markers in-vivo was 0.064 mm for the distance between markers and 0.31 degree for the angles between markers. Across-trial standard deviations for tibio-femoral translations were similar for all three motion directions, averaging 0.14 mm (range 0.08 to 0.20 mm). Variability in tibio-femoral rotations was more dependent on rotation axis, with across-trial standard deviations averaging 1.71 degrees for flexion/extension, 0.90 degree for internal/external rotation, and 0.40 degree for varus/valgus rotation. Advantages of this technique over traditional motion analysis methods include the elimination of skin motion artifacts, improved tracking precision and the ability to present results in a consistent anatomical reference frame.  相似文献   

19.
Kuo LC  Su FC  Chiu HY  Yu CY 《Journal of biomechanics》2002,35(11):1499-1506
While several different methods have been used to measure hand kinematics, fluoroscopy is generally considered to be the most accurate. Recently, video-based motion analysis has been developed for the measurement of joint kinematics. This method is versatile, easy to use, and can measure motions dynamically. Surface markers are most commonly used in the video-based motion systems. However, whether the surface markers placed on the thumb accurately represent the true kinematics of the underlying bony segment is questionable.In this study, the feasibility of surface markers to represent thumb kinematics was investigated by fluoroscopy. Both the positions of surface markers and bony landmarks were simultaneous recorded and then digitized. The Ra(2) values comparing the angular changes of the thumb interphalangeal, metacarpal and carpometacarpal joints derived using the surface markers or bony landmarks were 0.9986, 0.9730 and 0.9186 in the flexion/extension plane respectively, 0.8837, 0.9697 and 0.8775 in the abduction/adduction plane; and 0.9884, 0.9643 and 0.9431 in the opposition plane. The ranges, mean and standard deviation of the absolute differences between calculated angles of different marker sets were also compared. These data revealed that the similarities of the two different marker techniques throughout the motion cycle were high. The differences between the two methods were also within clinically allowable range of +/-5 degrees. It is concluded that the application of the video-based motion analysis system with surface markers to thumb kinematics is warranted.  相似文献   

20.
Accurate knowledge of the dynamic knee motion in-vivo is instrumental for understanding normal and pathological function of the knee joint. However, interpreting motion of the knee joint during gait in other than the sagittal plane remains controversial. In this study, we utilized the dual fluoroscopic imaging technique to investigate the six-degree-of-freedom kinematics and condylar motion of the knee during the stance phase of treadmill gait in eight healthy volunteers at a speed of 0.67 m/s. We hypothesized that the 6DOF knee kinematics measured during gait will be different from those reported for non-weightbearing activities, especially with regards to the phenomenon of femoral rollback. In addition, we hypothesized that motion of the medial femoral condyle in the transverse plane is greater than that of the lateral femoral condyle during the stance phase of treadmill gait. The rotational motion and the anterior–posterior translation of the femur with respect to the tibia showed a clear relationship with the flexion–extension path of the knee during the stance phase. Additionally, we observed that the phenomenon of femoral rollback was reversed, with the femur noted to move posteriorly with extension and anteriorly with flexion. Furthermore, we noted that motion of the medial femoral condyle in the transverse plane was greater than that of the lateral femoral condyle during the stance phase of gait (17.4±2.0 mm vs. 7.4±6.1 mm, respectively; p<0.01). The trend was opposite to what has been observed during non-weightbearing flexion or single-leg lunge in previous studies. These data provide baseline knowledge for the understanding of normal physiology and for the analysis of pathological function of the knee joint during walking. These findings further demonstrate that knee kinematics is activity-dependent and motion patterns of one activity (non-weightbearing flexion or lunge) cannot be generalized to interpret a different one (gait).  相似文献   