首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that stent geometry may cause local alterations in wall shear stress (WSS) that have been associated with neointimal hyperplasia and subsequent restenosis. However, previous CFD studies have ignored histological evidence of vascular straightening between circumferential stent struts. We tested the hypothesis that consideration of stent-induced vascular deformation may more accurately predict alterations in indexes of WSS that may subsequently account for histological findings after stenting. We further tested the hypothesis that the severity of these alterations in WSS varies with the degree of vascular deformation after implantation. Steady-state and time-dependent simulations of three-dimensional CFD arteries based on canine coronary artery measurements of diameter and blood flow were conducted, and WSS and WSS gradients were calculated. Circumferential straightening introduced areas of high WSS between stent struts that were absent in stented vessels of circular cross section. The area of vessel exposed to low WSS was dependent on the degree of circumferential vascular deformation and axial location within the stent. Stents with four vs. eight struts increased the intrastrut area of low WSS in vessels, regardless of cross-sectional geometry. Elevated WSS gradients were also observed between struts in vessels with polygonal cross sections. The results obtained using three-dimensional CFD models suggest that changes in vascular geometry after stent implantation are important determinants of WSS distributions that may be associated with subsequent neointimal hyperplasia.  相似文献   

2.
Following the deployment of a coronary stent and disruption of an atheromatous plaque, the deformation of the arterial wall and the presence of the stent struts create a new fluid dynamic field, which can cause an abnormal biological response. In this study 3D computational models were used to analyze the fluid dynamic disturbances induced by the placement of a stent inside a coronary artery. Stents models were first expanded against a simplified arterial plaque, with a solid mechanics analysis, and then subjected to a fluid flow simulation under pulsatile physiological conditions. Spatial and temporal distribution of arterial wall shear stress (WSS) was investigated after the expansion of stents of different designs and different strut thicknesses. Common oscillatory WSS behavior was detected in all stent models. Comparing stent and vessel wall surfaces, maximum WSS values (in the order of 1Pa) were located on the stent surface area. WSS spatial distribution on the vascular wall surface showed decreasing values from the center of the vessel wall portion delimited by the stent struts to the wall regions close to the struts. The hemodynamic effects induced by two different thickness values for the same stent design were investigated, too, and a reduced extension of low WSS region (<0.5Pa) was observed for the model with a thicker strut.  相似文献   

3.
Coronary artery stenosis is commonly treated by stent placement via percutaneous intervention, at times requiring multiple stents that may overlap. Stent overlap is associated with increased risk of adverse clinical outcome. While changes in local blood flow are suspected to play a role therein, hemodynamics in arteries with overlapping stents remain poorly understood. In this study we analyzed six cases of partially overlapping stents, placed ex vivo in porcine left coronary arteries and compared them to five cases with two non-overlapping stents. The stented vessel geometries were obtained by micro-computed tomography of corrosion casts. Flow and shear stress distribution were calculated using computational fluid dynamics. We observed a significant increase in the relative area exposed to low wall shear stress (WSS<0.5 Pa) in the overlapping stent segments compared both to areas without overlap in the same samples, as well as to non-overlapping stents. We further observed that the configuration of the overlapping stent struts relative to each other influenced the size of the low WSS area: positioning of the struts in the same axial location led to larger areas of low WSS compared to alternating struts. Our results indicate that the overlap geometry is by itself sufficient to cause unfavorable flow conditions that may worsen clinical outcome. While stent overlap cannot always be avoided, improved deployment strategies or stent designs could reduce the low WSS burden.  相似文献   

4.
BACKGROUND: Restenosis after stent implantation varies with stent design. Alterations in secondary flow patterns and wall shear stress (WSS) can modulate intimal hyperplasia via their effects on platelet and inflammatory cell transport toward the wall, as well as direct effects on the endothelium. METHOD OF APPROACH: Detailed flow characteristics were compared by estimating the WSS in the near-strut region of realistic stent designs using three-dimensional computational fluid dynamics (CFD), under pulsatile high and low flow conditions. The stent geometry employed was characterized by three geometric parameters (axial strut pitch, strut amplitude, and radius of curvature), and by the presence or lack of the longitudinal connector. RESULTS: Stagnation regions were localized around stent struts. The regions of low WSS are larger distal to the strut. Under low flow conditions, the percentage restoration of mean axial WSS between struts was lower than that for the high flow by 10-12%. The largest mean transverse shear stresses were 30-50% of the largest mean axial shear stresses. The percentage restoration in WSS in the models without the longitudinal connector was as much as 11% larger than with the connector The mean axial WSS restoration between the struts was larger for the stent model with larger interstrut spacing. CONCLUSION: The results indicate that stent design is crucial in determining the fluid mechanical environment in an artery. The sensitivity of flow characteristics to strut configuration could be partially responsible for the dependence of restenosis on stent design. From a fluid dynamics point of view, interstrut spacing should be larger in order to restore the disturbed flow; struts should be oriented to the flow direction in order to reduce the area of flow recirculation. Longitudinal connectors should be used only as necessary, and should be parallel to the axis. These results could guide future stent designs toward reducing restenosis.  相似文献   

5.
Restenosis resulting from neointimal hyperplasia (NH) limits the effectiveness of intravascular stents. Rates of restenosis vary with stent geometry, but whether stents affect spatial and temporal distributions of wall shear stress (WSS) in vivo is unknown. We tested the hypothesis that alterations in spatial WSS after stent implantation predict sites of NH in rabbit iliac arteries. Antegrade iliac artery stent implantation was performed under angiography, and blood flow was measured before casting 14 or 21 days after implantation. Iliac artery blood flow domains were obtained from three-dimensional microfocal X-ray computed tomography imaging and reconstruction of the arterial casts. Indexes of WSS were determined using three-dimensional computational fluid dynamics. Vascular histology was unchanged proximal and distal to the stent. Time-dependent NH was localized within the stented region and was greatest in regions exposed to low WSS and acute elevations in spatial WSS gradients. The lowest values of WSS spatially localized to the stented area of a theoretical artery progressively increased after 14 and 21 days as NH occurred within these regions. This NH abolished spatial disparity in distributions of WSS. The results suggest that stents may introduce spatial alterations in WSS that modulate NH in vivo.  相似文献   

6.
Coronary stent design affects the spatial distribution of wall shear stress (WSS), which can influence the progression of endothelialization, neointimal hyperplasia, and restenosis. Previous computational fluid dynamics (CFD) studies have only examined a small number of possible geometries to identify stent designs that reduce alterations in near-wall hemodynamics. Based on a previously described framework for optimizing cardiovascular geometries, we developed a methodology that couples CFD and three-dimensional shape-optimization for use in stent design. The optimization procedure was fully-automated, such that solid model construction, anisotropic mesh generation, CFD simulation, and WSS quantification did not require user intervention. We applied the method to determine the optimal number of circumferentially repeating stent cells (N(C)) for slotted-tube stents with various diameters and intrastrut areas. Optimal stent designs were defined as those minimizing the area of low intrastrut time-averaged WSS. Interestingly, we determined that the optimal value of N(C) was dependent on the intrastrut angle with respect to the primary flow direction. Further investigation indicated that stent designs with an intrastrut angle of approximately 40 deg minimized the area of low time-averaged WSS regardless of vessel size or intrastrut area. Future application of this optimization method to commercially available stent designs may lead to stents with superior hemodynamic performance and the potential for improved clinical outcomes.  相似文献   

7.
Intravascular brachytherapy (IVBT) has rapidly gained acceptance as a new treatment modality for reducing restenosis and improving the success rate of percutaneous transluminal coronary angioplasty (PTCA). Recent clinical results on patients treated with beta-emitting 32P stents suggest that radiation reduces in-stent restenosis but may exacerbate neointimal growth at the edges of the stents. This has been referred to as the "candy wrapper effect." It is well known that radioactive stents yield extremely inhomogeneous dose distributions, with low doses delivered to tissues in between stent struts, at the ends of the stent, and also at depth. Some animal model studies suggest that low doses of radiation may stimulate rather than inhibit neointimal growth in an injured vessel, and it is hypothesized that dose inhomogeneity at the ends of a stent may contribute to the candy wrapper effect. We present here a theoretical study comparing dose distributions for beta stents vs. gamma stents; "dumbbell" radioactive loaded stents vs. uniformly loaded stents; and stents with alternate strut design. Calculations demonstrate that dose inhomogenieties between stent struts, at the ends of stents, and at depth can be reduced by better stent design and isotope selection. Prior to the introduction of radioactive stents, criteria for stent design included factors such as trackability, flexibility, strength, etc. We show here that if stent design also includes criteria for strut shape and spacing that improved dose distributions are possible, which in turn could reduce the candy wrapper effect.  相似文献   

8.

Introduction  

The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that the vascular geometry created by an implanted stent causes local alterations in wall shear stress (WSS) that are associated with neointimal hyperplasia (NH). Foreshortening is a potential limitation of stent design that may affect stent performance and the rate of restenosis. The angle created between axially aligned stent struts and the principal direction of blood flow varies with the degree to which the stent foreshortens after implantation.  相似文献   

9.
The haemodynamic behaviour of blood inside a coronary artery after stenting is greatly affected by individual stent features as well as complex geometrical properties of the artery including tortuosity and curvature. Regions at higher risk of restenosis, as measured by low wall shear stress (WSS < 0.5 Pa), have not yet been studied in detail in curved stented arteries. In this study, three-dimensional computational modelling and computational fluid dynamics methodologies were used to analyse the haemodynamic characteristics in curved stented arteries using several common stent models. Results in this study showed that stent strut thickness was one major factor influencing the distribution of WSS in curved arteries. Regions of low WSS were found behind struts, particularly those oriented at a large angle relative to the streamwise flow direction. These findings were similar to those obtained in studies of straight arteries. An uneven distribution of WSS at the inner and outer bends of curved arteries was observed where the WSS was lower at the inner bend. In this study, it was also shown that stents with a helical configuration generated an extra swirling component of the flow based on the helical direction; however, this extra swirl in the flow field did not cause significant changes on the distribution of WSS under the current setup.  相似文献   

10.
Stent can cause flow disturbances on the endothelium and compliance mismatch and increased stress on the vessel wall. These effects can cause low wall shear stress (WSS), high wall shear stress gradient (WSSG), oscillatory shear index (OSI), and circumferential wall stress (CWS), which may promote neointimal hyperplasia (IH). The hypothesis is that stent-induced abnormal fluid and solid mechanics contribute to IH. To vary the range of WSS, WSSG, OSI, and CWS, we intentionally mismatched the size of stents to that of the vessel lumen. Stents were implanted in coronary arteries of 10 swine. Intravascular ultrasound (IVUS) was used to size the coronary arteries and stents. After 4 wk of stent implantation, IVUS was performed again to determine the extent of IH. In conjunction, computational models of actual stents, the artery, and non-Newtonian blood were created in a computer simulation to yield the distribution of WSS, WSSG, OSI, and CWS in the stented vessel wall. An inverse relation (R(2) = 0.59, P < 0.005) between WSS and IH was found based on a linear regression analysis. Linear relations between WSSG, OSI, and IH were observed (R(2) = 0.48 and 0.50, respectively, P < 0.005). A linear relation (R(2) = 0.58, P < 0.005) between CWS and IH was also found. More statistically significant linear relations between the ratio of CWS to WSS (CWS/WSS), the products CWS × WSSG and CWS × OSI, and IH were observed (R(2) = 0.67, 0.54, and 0.56, respectively, P < 0.005), suggesting that both fluid and solid mechanics influence the extent of IH. Stents create endothelial flow disturbances and intramural wall stress concentrations, which correlate with the extent of IH formation, and these effects were exaggerated with mismatch of stent/vessel size. These findings reveal the importance of reliable vessel and stent sizing to improve the mechanics on the vessel wall and minimize IH.  相似文献   

11.
Hemodynamic factors may affect the potential occurrence of in-stent restenosis (ISR) after intervention procedure of vertebral artery ostial stenosis (VAOS). The purpose of the present study is to investigate the influence of stent protrusion length in implantation strategy on the local hemodynamics of the VAOS. CTA images of a 58-year-old female patient with posterior circulation transient ischemic attack were used to perform a 3D reconstruction of the vertebral artery. Five models of the vertebral artery before and after the stent implantation were established. Model 1 was without stent implantation, Model 2–5 was with stent protruding into the subclavian artery for 0, 1, 2, 3 mm, respectively. Computational fluid dynamics simulations based on finite element analysis were employed to mimic the blood flow in arteries and to assess hemodynamic conditions, particularly the blood flow velocity and wall shear stress (WSS). The WSS and the blood flow velocity at the vertebral artery ostium were reduced by 85.33 and 35.36% respectively after stents implantation. The phenomenon of helical flow disappeared. Hemodynamics comparison showed that stent struts that protruded 1 mm into the subclavian artery induced the least decrease in blood speed and WSS. The results suggest that stent implantation can improve the hemodynamics of VAOS, while stent struts that had protruded 1 mm into the subclavian artery would result in less thrombogenesis and neointimal hyperplasia and most likely decrease the risk of ISR.  相似文献   

12.
The stimulation of endothelial cells by arterial wall shear stress (WSS) plays a central role in restenosis. The fluid-structure interaction between stent wire and blood flow alters the WSS, particularly between stent struts. We have designed an in vitro model of struts of an intra-vascular prosthesis to study blood flow through a 'stented' section. The experimental artery consisted of a transparent square section test vein, which reproduced the strut design (100x magnifying power). A programmable pump was used to maintain a steady blood flow. Particle image velocimetry method was used to measure the flow between and over the stent branches, and to quantify WSS. Several prosthesis patterns that were representative of the total stent strut geometry were studied in a greater detail. We obtained WSS values of between -1.5 and 1.5Pa in a weak SS area which provided a source of endothelial stimulation propitious to restenosis. We also compared two similar patterns located in two different flow areas (one at the entry of the stent and one further downstream). We only detected a slight difference between the weakest SS levels at these two sites. As the endothelial proliferation is greatly influenced by the SS, knowledge of the SS modification induced by the stent implantation could be of importance for intra-vascular prostheses design optimisation and thus can help to reduce the restenosis incidence rate.  相似文献   

13.
Polyvinyl alcohol (PVA) cryogel covered stents may reduce complications from thrombosis and restenosis by decreasing tissue prolapse. Finite element analysis was employed to evaluate the effects of PVA cryogel layers of varying thickness on tissue prolapse and artery wall stress for two common stent geometries and two vessel diameters. Additionally, several PVA cryogel covered stents were fabricated and imaged with an environmental scanning electron microscope. Finite element results showed that covered stents reduced tissue prolapse up to 13% and artery wall stress up to 29% with the size of the reduction depending on the stent geometry, vessel diameter, and PVA cryogel layer thickness. Environmental scanning electron microscope images of expanded covered stents showed the PVA cryogel to completely cover the area between struts without gaps or tears. Overall, this work provides both computational and experimental evidence for the use of PVA cryogels in covered stents.  相似文献   

14.
The deployment of a coronary stent near complex lesions can sometimes lead to incomplete stent apposition (ISA), an undesirable side effect of coronary stent implantation. Three-dimensional computational fluid dynamics (CFD) calculations are performed on simplified stent models (with either square or circular cross-section struts) inside an idealised coronary artery to analyse the effect of different levels of ISA to the change in haemodynamics inside the artery. The clinical significance of ISA is reported using haemodynamic metrics like wall shear stress (WSS) and wall shear stress gradient (WSSG). A coronary stent with square cross-sectional strut shows different levels of reverse flow for malapposition distance (MD) between 0 mm and 0.12 mm. Chaotic blood flow is usually observed at late diastole and early systole for MD=0 mm and 0.12 mm but are suppressed for MD=0.06 mm. The struts with circular cross section delay the flow chaotic process as compared to square cross-sectional struts at the same MD and also reduce the level of fluctuations found in the flow field. However, further increase in MD can lead to chaotic flow not only at late diastole and early systole, but it also leads to chaotic flow at the end of systole. In all cases, WSS increases above the threshold value (0.5 Pa) as MD increases due to the diminishing reverse flow near the artery wall. Increasing MD also results in an elevated WSSG as flow becomes more chaotic, except for square struts at MD=0.06 mm.  相似文献   

15.
Despite technical and mechanical improvement in coronary stents the incidence of restenosis caused by in-stent neointimal hyperplasia remains high. Oral administration of numerous pharmacological agents has failed to reduce restenosis after coronary stenting in humans, possibly owing to insufficient local drug concentration. Therefore, drug-eluting stents were developed as a vehicle for local drug administration. The authors developed a new drug-eluting polymer stent that is made of poly-l-lactic acid polymer mixed with tranilast, an anti-allergic drug that inhibits the migration and proliferation of vascular smooth muscle cells induced by platelet-derived growth factor and transforming growth factor->1. Polymer stents might be superior to polymer-coated metallic stents as local drug delivery stents in terms of biodegradation and the amount of loaded drug. Drug-mixed polymer stents can be loaded with a larger amount of drug than can drug-coated metallic stents because the polymer stent struts can contain the drug. Clinical application is required to assess the safety and efficacy of drug-eluting polymer stents against stent restenosis.  相似文献   

16.
To reduce in-stent restenosis rates, we developed a novel drug-eluting covered stent with a microporous elastometric covered film, in which its luminal surface was flat and immobilized with heparin for anticoagulation and its outer surface immobilized with FK506 to prevent neointimal hyperplasia. One month after implantation into the bilateral common carotid arteries, all stented arteries were patent and the luminal surfaces were fully covered with a confluent of endothelial cells irrespective of the drug immobilization. In the control group, which consisted of covered stents without drug immobilization, intensive inflammatory cells adjacent to the stents and neointimal hyperplasia, indicating vascular injury, were observed. In contrast, in the developed drug-eluting stents, only a few inflammatory cells around the stent strut and covered film were observed, and there was no significant neointimal thickening.  相似文献   

17.
There is a growing interest in virtual tools to assist clinicians in evaluating different procedures and devices for endovascular treatment. In the present study we use finite element analysis to investigate the influence of stent design and vessel geometry for stent assisted coiling of intracranial aneurysms. Nine virtual stenting procedures were performed: three nitinol stent designs ((i) an open cell stent resembling the Neuroform, (ii) a generic stiff and (iii) a more flexible closed cell design), were deployed in three patient-specific cerebral aneurysmatic vessels. We investigated the percentage of strut area covering the aneurysm neck, the straightening induced on the cerebrovasculature by the stent placement (quantified by the reduction in tortuosity), and stent apposition to the wall (quantified as the percentage of struts within 0.2mm of the vessel). The results suggest that the open cell design better covers the aneurysm neck (11.0±1.1%) compared to both the stiff (7.8±1.6%) and flexible (8.7±1.6%) closed cell stents, and induces less straightening of the vessel (-5.1±1.6% vs. -42.9±9.8% and -26.9±11.9% ). The open cell design has, however, less struts apposing well to the vessel wall (56.0±6.4%) compared to the flexible (73.4±4.6%) and stiff (70.4±5.1%) closed cell design. With the presented study, we hope to contribute to and improve aneurysm treatment, using a novel patient specific environment as a possible pre-operative tool to evaluate mechanical stent behavior in different vascular geometries.  相似文献   

18.
BackgroundMultiple overlapping uncovered stents (MOUS) system has shown potentials in managing complex aortic aneurysms with side branches involvement. It promotes the development of thrombus by modulating local flow pattern that reduces the wall tension, while maintaining patency of side branches. However the modulation of local hemodynamic parameters depends on various factors that have not been assessed comprehensively.MethodsAneurysm 3D geometry was reconstructed based on CT images. One-way fluid-structure interaction analysis was performed to quantify structural stress concentration in the wall, and changes of blood velocity, wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT) and pressure in the sac due to the stent deployment.ResultsHigh structural stress concentration due to stent deployment was found in the landing zone and it increased linearly with the number of stents deployed. The wall tension in the sac was unaffected by the stent deployment. Stress within the wall was insensitive to the different overlapping pattern. After one stent was deployed, the mean flow velocity in the sac reduced by 36.4%. The deployment of the 2nd stent further reduced the mean sac velocity by 10%. WSS decreased while both OSI and RRT increased after stent deployment, however pressure in the sac remained nearly unchanged. Except for the cases with complete stents struts alignment, different overlapping pattern had little effect on flow parameters.ConclusionsMechanical parameters modulated by the MOUS are insensitive to different overlapping pattern suggesting that endovascular procedure can be performed with less attention to the overlapping pattern.  相似文献   

19.
Phosphorylcholine (PC)-coated stents have shown excellent blood and tissue biocompatibility in porcine coronary arteries. The purpose of this study was to determine the efficacy of local methylprednisolone (MP) delivery using PC-coated stents to inhibit inflammatory response and in-stent neointimal hyperplasia in an overstretched porcine coronary model. BiodivYsio (Biocompatibles, Farnham, Surrey, UK) PC-coated drug delivery (DD) stents and DD stents loaded with a high dose of MP (269 microg) were implanted in the coronary arteries of 20 pigs with a balloon/artery ratio of 1.2 : 1. At five days the peri-strut inflammatory response score and thrombus score of the MP-loaded DD stents were lower than in the control stents. The neointimal hyperplasia of MP-loaded DD stents was significantly reduced (0.80 +/- 0.10 versus 0.48 +/- 0.10 mm(2), p < 0.01). At four-week follow-up, the inflammatory response of MP-loaded stents was lower than the control stents, but without significant difference. The MP-loaded stents showed decreased peri-strut arterial injury and in-stent neointimal hyperplasia (2.42 +/- 0.87 versus 1.62 +/- 0.71 mm(2), p < 0.05). It is concluded that local vascular delivery of a high dose of MP from PC-coated DD stents could effectively decrease inflammatory response and thrombus formation after oversized stent deployment and result in a significant reduction of neointimal hyperplasia.  相似文献   

20.
Carotid artery stenting (CAS) has emerged as a minimally invasive alternative to endarterectomy but its use in clinical treatment is limited due to the post-stenting complications. Haemodynamic actors, related to blood flow in the stented vessel, have been suggested to play a role in the endothelium response to stenting, including adverse reactions such as in-stent restenosis and late thrombosis. Accessing the flow-related shear forces acting on the endothelium in vivo requires space and time resolutions which are currently not achievable with non-invasive clinical imaging techniques but can be obtained from image-based computational analysis. In this study, we present a framework for accurate determination of the wall shear stress (WSS) in a mildly stenosed carotid artery after the implantation of a stent, resembling the commercially available Acculink (Abbott Laboratories, Abbott Park, Illinois, USA). Starting from angiographic CT images of the vessel lumen and a micro-CT scan of the stent, a finite element analysis is carried out in order to deploy the stent in the vessel, reproducing CAS in silico. Then, based on the post-stenting anatomy, the vessel is perfused using a set of boundary conditions: total pressure is applied at the inlet, and impedances that are assumed to be insensitive to the presence of the stent are imposed at the outlets. Evaluation of the CAS outcome from a geometrical and haemodynamic perspective shows the presence of atheroprone regions (low time-average WSS, high relative residence time) colocalised with stent malapposition and stent strut interconnections. Stent struts remain unapposed in the ostium of the external carotid artery disturbing the flow and generating abnormal shear forces, which could trigger thromboembolic events.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号