首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two studies were conducted in 83 college men to determine the degree of generality of individual differences in upper body muscular strength assessed by different testing modes. In study 1 (N = 43), correlations were computed between four measures of upper body strength using the bench press movement, maximal isokinetic (0.09 rad.s-1), maximal fast (0.126 m.s-1) and slow (0.037 m.s-1) hydraulic, and one repetition maximum (1-RM) free weight bench press (BP). Compared to free weight BP, maximal strength during isokinetic and slow hydraulic BP was approximately 29% and approximately 8% larger, and fast hydraulic BP strength was approximately 63% lower (p less than 0.05). Simple linear regression of isokinetic BP on 1-RM BP yielded r = 0.79, error of prediction (SE) = 12%, and generality = 81%. The corresponding averaged values for the regression of slow and fast hydraulic BP on free weight 1-RM BP were r = 0.77, SE = 13.5%, and generality = 84%. In Study 2 (N = 40), testing included maximal isokinetic concentric and eccentric arm flexion and extension at 0.524, 1.570, and 2.094 rad.s-1. The ratio of concentric to eccentric torque at the 3 speeds averaged 0.68 (flexion) and 0.70 (extension), and eccentric torques were 32% and 30% greater than concentric torques (p less than 0.05). The linear regression between concentric vs. eccentric flexion and extension torques at the three velocities yielded an average r = 0.80, SE = 13.7%, and generality = 73%.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
Measures of knee joint function, although useful in predicting injury, can be misleading because hip position in traditional seated isokinetic tests is dissimilar to when injuries occur. This study aimed to determine the differences between seated and supine peak torques and strength ratios and examine the interaction of position with joint velocity. This was a cross-sectional, repeated measures study. Isokinetic knee extensor and flexor concentric and eccentric peak torque was measured seated and supine (10° hip flexion) at 1.04 and 3.14 rad·s(-1) in 11 Rugby players. Repeated measures analysis of variance and paired t-tests were used to analyze peak torques and strength ratios. Bonferroni post hoc, limits of agreement, and Pearson's correlation were applied. Seated peak torque was typically greater than that for supine for muscle actions and velocities. The values ranged from 109 ± 18 N·m (mean ± σ) for supine hamstring concentric peak torque at 1.04 rad·s(-1) to 330 ± 71 for seated quadriceps eccentric peak torque at 1.04 rad·s(-1). There was a significant position × muscle action interaction; eccentric peak torque was reduced more than concentric in the supine position. Knee joint strength ratios ranged from 0.47 ± 0.06 to 0.86 ± 0.23, with a significant difference in means between supine and seated positions for functional ratio at 3.14 rad·s(-1) observed; for seated it was 0.86 ± 0.23; and for supine, it was 0.68 ± 0.15 (p < 0.05). Limits of agreement for traditional and functional ratios ranged from 1.09 ×/÷ 1.37 to 1.13 ×/÷ 1.51. We conclude that hip angle affects isokinetic peak torques and knee joint strength ratios. Therefore, the hip angle should be nearer 10° when measuring knee joint function because this is more ecologically valid. Using similar protocols, sports practitioners can screen for injury and affect training to minimize injury.  相似文献   

3.
The primary purpose of this investigation was to study the eccentric and concentric torque-velocity characteristics of the quadriceps femoris in man using a recently developed combined isometric, concentric and eccentric controlled velocity dynamometer (the SPARK System). A secondary purpose was to compare the method error associated with maximal voluntary concentric and eccentric torque output over a range of testing velocities. 21 males (21-32 years) performed on two separate days maximal voluntary isometric, concentric and eccentric contractions of the quadriceps femoris at 4 isokinetic lever arm velocities of 0 degree.s-1 (isometric), 30 degrees.s-1, 120 degrees.s-1 and 270 degrees.s-1. Eccentric peak torque and angle-specific torques (measured every 10 degrees from 30 degrees to 70 degrees) did not significantly change from 0 degrees.s-1 to 270 degrees.s-1 (p greater than 0.005) with the exception of angle-specific 40 degrees torque, which significantly increased; p less than 0.05). The mean method error was significantly higher for the eccentric tests (10.6% +/- 1.6%) than for the concentric tests (8.1% +/- 1.7%) (p less than 0.05). The mean method error decreased slightly with increasing concentric velocity (p greater than 0.05), and increased slightly with increasing eccentric velocity (p greater than 0.05). A tension restricting neural mechanism, if active during maximal eccentric contractions, could possibly account for the large difference seen between the present eccentric torque-velocity results and the classic results obtained from isolated animal muscle.  相似文献   

4.
The purpose of this study was to determine the relationship between hip and knee strength, and valgus knee motion during a single leg squat. Thirty healthy adults (15 men, 15 women) stood on their preferred foot, squatted to approximately 60 deg of knee flexion, and returned to the standing position. Frontal plane knee motion was evaluated using 3-D motion analysis. During Session 2, isokinetic (60 deg/sec) concentric and eccentric hip (abduction/adduction, flexion/extension, and internal/external rotation) and knee (flexion/extension) strength was evaluated. The results demonstrated that hip abduction (r2=0.13), knee flexion (r2=0.18), and knee extension (r2=0.14) peak torque were significant predictors of frontal plane knee motion. Significant negative correlations showed that individuals with greater hip abduction (r=-0.37), knee flexion (r=-0.43), and knee extension (r=-0.37) peak torque exhibited less motion toward the valgus direction. Men exhibited significantly greater absolute peak torque for all motions, excluding eccentric internal rotation. When normalized to body mass, men demonstrated significantly greater strength than women for concentric hip adduction and flexion, knee flexion and extension, and eccentric hip extension. The major findings demonstrate a significant role of hip muscle strength in the control of frontal plane knee motion.  相似文献   

5.
The speed-torque relationship of the right knee extensor muscle group was investigated in eight untrained subjects (28 +/- 2 yr old). Torque was measured at a specific knee angle during isokinetic concentric or eccentric actions at nine angular velocities (0.17-3.66 rad/s) and during isometric actions. Activation was by "maximal" voluntary effort or by transcutaneous tetanic electrical stimulation that induced an isometric torque equal to 60% (STIM 1) or 45% (STIM 2) of the voluntary isometric value. Torque increased (P less than 0.05) to 1.4 times isometric as the speed of eccentric actions increased to 1.57 rad/s for STIM 1 and STIM 2. Thereafter, increases in eccentric speed did not further increase torque. Torque did not increase (P greater than 0.05) above isometric for voluntary eccentric actions. As the speed of concentric actions increased from 0.00 to 3.66 rad/s, torque decreased (P less than 0.05) more (P less than 0.05) for both STIM 1 and STIM 2 (two-thirds) than for voluntary activation (one-half). As a result of these responses, torque changed three times as much (P less than 0.05) across speeds of concentric and eccentric actions with artificial (3.4-fold) than voluntary (1.1-fold) activation. The results indicate that with artificial activation the normalized speed-torque relationship of the knee extensors in situ is remarkably similar to that of isolated muscle. The relationship for voluntary activation, in contrast, suggests that the ability of the central nervous system to activate the knee extensors during maximal efforts depends on the speed and type of muscle action performed.  相似文献   

6.
Day-to-day variability and single-measurement reliability of selected isokinetic knee extension-flexion strength and endurance indices were assessed in 10 adult men and 8 adult women. On three occasions separated by at least 5 days, the subjects completed 4 reciprocal maximal voluntary contractions (MVC) at different angular velocities (1.05 rad.s-1 and 3.14 rad.s-1). The men also completed a muscular endurance test consisting of 30 reciprocal, MVC at 3.14 rad.s-1. Coefficient of variation, intra-class correlation coefficient and standard error of single-measurement scores support the continued use of gravity corrected peak torque (PT) and average peak torque (APT) as indices of isokinetic leg strength. Similarly, gravity corrected APT and total work should be the recommended indices of isokinetic leg muscular endurance in men. The results suggest that these isokinetic indices must be assessed using multiple day-to-day trial protocols adequately to describe performance capacity. Composite indices such as the ratio of Knee flexion to extension PT and fatigue measurements offer considerably reduced reliability and a greater potential for misinterpretation. The reliability of knee extension indices generally exceeds that of flexion indices. Similar variability and reproducibility of responses were observed between men and women and between reciprocal contractions performed at angular velocities of 1.05 rad.s-1 and 3.14 rad.s-1.  相似文献   

7.
The aim of this study was to evaluate the Kin-Com II dynamometer in the study of the stretch-shortening cycle (a concentric muscle action preceded by an eccentric muscle action). Measurements were made of plantar flexion at different angular velocities (120 degrees.s-1 and 240 degrees.s-1) with the knee at two different angles (0 degree and 90 degrees). Ten healthy women ranging in age from 22 to 41 years were studied. Torque values were recorded simultaneously with surface electromyograms (EMG): maximal voluntary concentric torque values were recorded and, after a short rest, the torque values of the concentric action which followed immediately after an eccentric action of the same velocity, both with maximal effort. Mean values were taken at different ankle positions and also averaged over different ranges. A concentric action preceded by an eccentric action generated a torque value on an average about 100% larger than a concentric action alone. The EMG activity was lower or unchanged. It was concluded that the present method could be useful in the study of the stretch-shortening cycle in plantar flexion and in the testing of the behaviour of the elastic components in people with disabilities in the lower limbs.  相似文献   

8.
The purpose of this study was to compare pure eccentric and concentric isokinetic training with respect to their possible specificity in the adaptation of strength and morphology of the knee extensor muscles. Ten moderately trained male physical education students were divided into groups undertaking eccentric (ETG) and concentric (CTG) training. They performed 10 weeks of maximal isokinetic (90 degrees x s(-1)) training of the left leg, 4x10 repetitions - three times a week, followed by a second 10-week period of similar training of the right-leg. Mean eccentric and concentric peak torques increased by 18% and 2% for ETG and by 10% and 14% for CTG, respectively. The highest increase in peak torque occurred in the eccentric 90 degrees x s(-1) test for ETG (35%) whereas in CTG strength gains ranged 8%-15% at velocities equal or lower than the training velocity. Significant increases in strength were observed in the untrained contra-lateral leg only at the velocity and mode used in ipsilateral training. Cross-sectional area of the quadriceps muscle increased 3%-4% with training in both groups, reaching statistical significance only in ETG. No major changes in muscle fibre composition or areas were detected in biopsies from the vastus lateralis muscle for either leg or training group. In conclusion, effects of eccentric training on muscle strength appeared to be more mode and speed specific than corresponding concentric training. Only minor adaptations in gross muscle morphology indicated that other factors, such as changes in neural activation patterns, were causing the specific training-induced gains in muscle strength.  相似文献   

9.
The influence of muscle activation and the time allowed for torque generation on the angle-specific torque-velocity relationship of the triceps surae was studied during plantar flexion using supramaximal electrical stimulation and a release technique on six male subjects [mean (SD) age 25 (4) years]. Torque-velocity data were obtained under different levels of constant muscle activation by varying the stimulus frequency and the time allowed for isometric torque generation prior to release and isokinetic shortening. To eliminate the effects of the frequency response on absolute torque the isokinetic data were normalized to the maximum isometric torque values at 0.44 rad. There were no significant differences in the normalized torques generated at any angular velocity using stimulus frequencies of 20, 50 or 80 Hz. When the muscle was stimulated at 50 Hz the torques obtained after a 400 ms and 1 s pre-release isometric contraction did not differ significantly. However, with no pre-release contraction significantly less torque was generated at all angular velocities beyond 1.05 rad · s–1 when compared with either the 200, 400 ms or 1 s condition. With a 200 ms pre-release contraction significantly less torque was generated at angular velocities beyond 1.05 rad · s–1 when compared with the 400 ms or 1 s conditions. It would seem that the major factor governing the shape of the torque-velocity curve at a constant level of muscle activation is the time allowed for torque generation.  相似文献   

10.
The purpose of this investigation was to compare children and adults of both genders with respect to torque-velocity, electromyogram (EMG)-velocity and torque-EMG relationships during maximal voluntary knee extensor muscle actions. Four groups of ten subjects each were studied comprising 11-year-old girls and boys and female and male physical education students (22–35 years). Maximal voluntary eccentric (lengthening) and concentric (shortening) actions of the knee extensors were performed at the constant velocities of 45, 90 and 180° · s–1. Average values for torque and EMG activity, recorded by surface electrodes from the quadriceps muscle, were taken for the mid 40° of the 80° range of motion. The overall shapes of the torque- and EMG-velocity relationships were similar for all four groups, showing effects of velocity under concentric (torque decrease and EMG increase) but not under eccentric conditions. Eccentric torques were always greater than velocity-matched concentric ones, whereas the eccentric EMG values were lower than the concentric ones at corresponding velocities. Torque output per unit EMG activity was clearly higher for eccentric than for concentric conditions and the difference was of similar magnitude for all groups. Thus, the torque-EMG-velocity relationships would appear to have been largely independent of gender and to be fully developed at a prepubertal age.  相似文献   

11.
The purpose of this study was to investigate the force-producing characteristics of boys aged 13 years in relation to fatigue of elbow flexor muscles. Maximal voluntary force in elbow flexion was measured before and after a muscle endurance test (MET) by using an isokinetic dynamometer isometrically, concentrically and eccentrically at three velocities, i.e. 0.21, 0.52, and 1.05 rad · s–1. The MET consisted of maximal concentric and eccentric muscle actions performed alternately at 0.52 rad · s–1 for 50 consecutive trials. Muscle cross-sectional area (CSA) of elbow flexor muscles (biceps brachii and brachialis) was measured by a B-mode ultrasound apparatus. Although eccentric force showed significantly higher values than concentric force during MET, there was no significant difference in the rate of decline in force between the two actions. There was no significant difference in the rate of decline in force after MET for each velocity and muscle action. Isometric, concentric and eccentric force before MET was significantly related to muscle CSA whereas, after MET, concentric force significantly correlated with muscle CSA but there was no significant correlation between muscle CSA and isometric or eccentric force. From our study, it is therefore suggested that in development to maturity, isometric, concentric and eccentric force decrease at the same rate with advancing muscle fatigue; however, there might be differences among muscle actions in facors affecting force development.  相似文献   

12.
The force exerted by a muscle is a function of the activation level and the maximum (tetanic) muscle force. In "maximum" voluntary knee extensions muscle activation is lower for eccentric muscle velocities than for concentric velocities. The aim of this study was to model this "differential activation" in order to calculate the maximum voluntary knee extensor torque as a function of knee angular velocity. Torque data were collected on two subjects during maximal eccentric-concentric knee extensions using an isovelocity dynamometer with crank angular velocities ranging from 50 to 450 degrees s(-1). The theoretical tetanic torque/angular velocity relationship was modelled using a four parameter function comprising two rectangular hyperbolas while the activation/angular velocity relationship was modelled using a three parameter function that rose from submaximal activation for eccentric velocities to full activation for high concentric velocities. The product of these two functions gave a seven parameter function which was fitted to the joint torque/angular velocity data, giving unbiased root mean square differences of 1.9% and 3.3% of the maximum torques achieved. Differential activation accounts for the non-hyperbolic behaviour of the torque/angular velocity data for low concentric velocities. The maximum voluntary knee extensor torque that can be exerted may be modelled accurately as the product of functions defining the maximum torque and the maximum voluntary activation level. Failure to include differential activation considerations when modelling maximal movements will lead to errors in the estimation of joint torque in the eccentric phase and low velocity concentric phase.  相似文献   

13.
The effect of an increased angle of excursion and isometric pre-activation on isokinetic torques of knee extensors was investigated in five male subjects, mean age 35.0 years, SD 9.6. Peak torque and isoangular torque at 0.52 rad from full knee extension (FKE) were measured when contractions were carried out at 3.14, 4.19 and 5.24 rad.s-1 starting: 1) from a standard knee angle (SA) of 1.57 rad from FKE, 2) from the same starting angle as SA, plus an isometric preload (P) equivalent to 25% of isometric maximal voluntary contraction and 3) from an increased angle of knee flexion (IA), 2.09 rad from FKE plus P. Surface integrated electromyograms (iEMG) of the vastus lateralis muscle in SA and IA + P were also recorded. The IA + P had the effect of increasing peak torque, as compared to SA, on average by 12.0%, SD 7.5% (P less than 0.001) at 3.14 rad.s-1, 19.5%, SD 5.5% (P less than 0.001) at 4.19 rad.s-1, 21.6%, SD 10.7% (P less than 0.001) at 5.24 rad.s-1 and of increasing mean iEMG by 15.7%, SD 7.0% (P less than 0.001) at 5.24 rad.s-1. The IA + P also had the effect of increasing the angle from FKE at which peak torque occurred: from means of 0.80 rad, SD 0.11 to 1.00 rad, SD 0.07 at 3.14 rad.s-1, from 0.65 rad, SD 0.11 to 0.92 rad, SD 0.09 at 4.19 rad.s-1 and from 0.60 rad, SD 0.11 to 0.88 rad, SD 0.11 at 5.24 rad.s-1 (P less than 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
Static and dynamic assessment of the Biodex dynamometer   总被引:2,自引:0,他引:2  
The validity and accuracy of the Biodex dynamometer was investigated under static and dynamic conditions. Static torque and angular position output correlated well with externally derived data (r = 0.998 and r greater than 0.999, respectively). Three subjects performed maximal voluntary knee extensions and flexions at angular velocities from 60 to 450 degrees.s-1. Using linear accelerometry, high speed filming and Biodex software, data were collected for lever arm angular velocity and linear accelerations, and subject generated torque. Analysis of synchronized angular position and velocity changes revealed the dynamometer controlled angular velocity of the lever arm to within 3.5% of the preset value. Small transient velocity overshoots were apparent on reaching the set velocity. High frequency torque artefacts were observed at all test velocities, but most noticeably at the faster speeds, and were associated with lever arm accelerations accompanying directional changes, application of resistive torques by the dynamometer, and limb instability. Isokinematic torques collected from ten subjects (240, 300 and 400 degrees.s-1) identified possible errors associated with reporting knee extension torques at 30 degrees of flexion. As a result of tissue and padding compliance, leg extension angular velocity exceeded lever arm angular velocity over most of the range of motion, while during flexion this compliance meant that knee and lever arm angles were not always identical, particularly at the start of motion. Nevertheless, the Biodex dynamometer was found to be both a valid and an accurate research tool; however, caution must be exercised when interpreting and ascribing torques and angular velocities to the limb producing motion.  相似文献   

15.
Based on the limited ability of the human being to voluntarily control submaximal eccentric exertions, previous studies have indicated that isokinetic testing with a combined concentric–eccentric exercise protocol could effectively identify submaximal (feigned) effort in various muscle groups by showing an abnormally high eccentric to concentric ratio (ECR). The objective of this study was to determine the validity and accuracy of an ECR-based isokinetic test in identifying feigned ankle weakness. Thirty-eight normal subjects performed maximal and feigned efforts in an isokinetic concentric and eccentric ankle plantar- and dorsiflexion protocol with two different velocities, 30 and 120° s−1. The isokinetic parameters ECR and the derivatives DEC (difference between ECR at high speed of motion and ECR at low speed of motion) and SEC (sum of ECR at high speed of motion plus the ratio between eccentric peak torque at high speed and concentric peak torque at low speed) were calculated. The ECR, DEC and SEC scores were significantly greater in feigned conditions for ankle plantarflexion, but not for dorsiflexion. Using optimal cutoff scores based on 99% tolerance intervals, it was disclosed that the most efficient parameter was the SEC, identifying 92% of the feigned efforts with 99% confidence, indicating that the ankle plantarflexors are less controllable in fast eccentric conditions than that in concentric conditions. The ECR-based parameters are valid for effectively identifying feigned plantarflexion effort with high accuracy, but do not allow the detection of feigned dorsiflexion weakness.  相似文献   

16.
17.
Measurements of human strength can be important during analyses of physical activities. Such measurements have often taken the form of the maximum voluntary torque at a single joint angle and angular velocity. However, the available strength varies substantially with joint position and velocity. When examining dynamic activities, strength measurements should account for these variations. A model is presented of maximum voluntary joint torque as a function of joint angle and angular velocity. The model is based on well-known physiological relationships between muscle force and length and between muscle force and velocity and was tested by fitting it to maximum voluntary joint torque data from six different exertions in the lower limb. Isometric, concentric and eccentric maximum voluntary contractions were collected during hip extension, hip flexion, knee extension, knee flexion, ankle plantar flexion and dorsiflexion. Model parameters are reported for each of these exertion directions by gender and age group. This model provides an efficient method by which strength variations with joint angle and angular velocity may be incorporated into comparisons between joint torques calculated by inverse dynamics and the maximum available joint torques.  相似文献   

18.
The aim of this investigation was to study the relationships among movement velocity, torque output and electromyographic (EMG) activity of the knee extensor muscles under eccentric and concentric loading. Fourteen male subjects performed maximal voluntary eccentric and concentric constant-velocity knee extensions at 45, 90, 180 and 360 degrees.s-1. Myoelectric signals were recorded, using surface electrodes, from the vastus medialis, vastus lateralis and rectus femoris muscles. For comparison, torque and full-wave rectified EMG signals were amplitude-averaged through the central half (30 degrees-70 degrees) of the range of motion. For each test velocity, eccentric torque was greater than concentric torque (range of mean differences: 20%-146%, P less than 0.05). In contrast, EMG activity for all muscles was lower under eccentric loading than velocity-matched concentric loading (7%-31%, P less than 0.05). Neither torque output nor EMG activity for the three muscles changed across eccentric test velocities (P greater than 0.05). While concentric torque increased with decreasing velocity, EMG activity for all muscles decreased with decreasing velocity (P less than 0.05). These data suggest that under certain high-tension loading conditions (especially during eccentric muscle actions), the neural drive to the agonist muscles was reduced, despite maximal voluntary effort. This may protect the musculoskeletal system from an injury that could result if the muscle was to become fully activated under these conditions.  相似文献   

19.
This study investigated the effects of dynamic knee extension and flexion fatiguing task on torque and neuromuscular responses in young and older individuals. Eighteen young (8 males; 25.1 ± 3.2 years) and 17 older (8 males; 69.7 ± 3.7 years) volunteered. Following a maximal voluntary isometric contraction test, participants performed a fatiguing task involving 22 maximal isokinetic (concentric) knee extension and flexion contractions at 60°/s, while surface EMG was recorded simultaneously from the knee extensors (KE) and flexors (KF). Fatigue-induced relative torque reductions were similar between age groups for KE (peak torque decrease: 25.15% vs 26.81%); however, KF torque was less affected in older individuals (young vs older peak torque decrease: 27.6% vs 11.5%; p < 0.001) and this was associated with greater increase in hamstring EMG amplitude (p < 0.001) and hamstrings/quadriceps peak torque ratio (p < 0.01). Furthermore, KE was more fatigable than KF only among older individuals (peak torque decrease: 26.8% vs 11.5%; p < 0.001). These findings showed that the age-related fatigue induced by a dynamic task was greater for the KE, with greater age-related decline in KE compared to KF.  相似文献   

20.
Maximal isokinetic knee extensor strength was measured as torque in 17 young (mean age +/- SD, 21 +/- 3 years) and 16 elderly (68 +/- 5 years) women at 30 degrees (0.52 rad) before full extension, at angular velocities from 0 to 5.24 rad s-1, in 7 increments of 0.87 rad s-1. The elderly women were significantly weaker than the young women at all angular velocities. The rate of loss of absolute torque with increasing velocity was similar for both age groups, but when torque was standardised as a percentage of the individual's maximum, the elderly group showed a significantly greater rate of loss than the younger group. Quick-release from an isometric effort did not increase the recorded torques at 4.36 rad s-1 compared with the free-running method in either age group. The age differences are compatible with lower ratio of type II to type I fibre are in the older group.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号