首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A method is presented for the chiral analysis of amino acids in biological fluids using micellar electrokinetic chromatography (MEKC) and laser-induced fluorescence (LIF). The amino acids are derivatized with the chiral reagent (+/−)-1-(9-anthryl)-2-propyl chloroformate (APOC) and separated using a mixed micellar separation system. No tedious pre-purification of samples is required. The excellent separation efficiency and good detection capabilities of the MEKC-LIF system are exemplified in the analysis of urine and cerebrospinal fluid. This is the first time MEKC has been reported for chiral analysis of amino acids in biological fluids. The amino acids -alanine, -glutamine, and -aspartic acid have been observed in cerebrospinal fluid, and -alanine and -glutamic acid in urine. To the best of our knowledge no measurements of either -alanine in cerebrospinal fluid or -glutamic acid in urine have been presented in the literature before.  相似文献   

2.
4-Hydroxnonenal (HNE) is a product of lipid peroxidation in biological systems that causes a variety of harmful biological effects. A method for identifying HNE based on derivatization with the fluorescent reagent dansylhydrazine (5-(dimethylamino)naphthalene-1-sulphonehydrazine (DNSH) followed by micellar electrokinetic chromatography separation laser-induced fluorescence detection has been developed. The derivatization reaction has also been investigated for significant experimental parameters and rat brain homogenates with induced lipid peroxidation have been analysed for HNE contents. The limit of detection (3 S/N) was 30 nM or 0.3 fmol in the injected sample.  相似文献   

3.
An assay for spermidine synthase (SPDS) activity in rat liver has been developed using micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection to enable the discovery of SPDS inhibitors. The assay was established by estimating the amount of spermidine (SPD) produced from the putrescine (PUT) present by SPDS. The SPD in an enzyme reaction mixture of homogenized rat liver could directly react with 7-fluoro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) as a fluorescence derivatization reagent. The NBD derivatives of SPD and PUT could be separated and detected by MEKC-LIF detection within 15 min. The IC(50) value measured for SPDS inhibitor, 4-methylcyclohexylamine, in rat liver by this assay was consistent with published data. Our SPDS assay using MEKC-LIF is simple and allows easy determination of SPDS activity in homogenized samples without troublesome procedures such as preparation of antibody or fluorescence-labeled substrate. The assay should be effective for discovering the SPDS inhibitors using biological samples.  相似文献   

4.
Micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection has been developed for a protein kinase assay. This protein kinase assay could readily determine the phosphorylation activity of substrate peptide kemptide using cAMP-dependent protein kinase (PKA) as a model enzyme. Kemptide and phosphorylated kemptide could be reacted with 7-fluoro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) as a fluorescence derivatization reagent for LIF detection by directly adding NBD-F into the PKA enzymatic reaction mixture. These derivatives of substrate and product were separated and detected within the analysis time of 5 min by micellar electrokinetic mode using a mixture of sodium dodecylsulfate and methanol as a running buffer. Good linearity of the peak response of the phosphorylated kemptide was obtained over the range of 1-20 mU/tube of PKA in the assay. The relative standard deviation of the peak areas of the phosphorylated kemptide using 2, 5 and 10 mU/tube of PKA were calculated to <10.4%, indicating that the assay was reproducible. Also, IC(50) values of six PKA inhibitors, the K(i) value and the inhibition pattern of one inhibitor, which were calculated to estimate by the variation of the peak area of the phosphorylated kemptide using 5 mU/tube of PKA, were consistent with the published data. The sensitivity of the assay was higher than that of enzyme-linked immunosorbent assay (ELISA) for PKA phosphorylation activity, as IC(50) values, K(i) value, and the inhibition mechanism of inhibitors could be estimated using one-tenth amounts of PKA, compared with that of ELISA. The MEKC-LIF is expected to be very useful for protein kinase assay and its application to the estimation of inhibitors because this method does not entail experimentally troublesome procedures such as the preparation of antibody or fluorescence-labeled substrate.  相似文献   

5.
A non-competitive immunoassay based on micellar electrokinetic capillary chromatography (MECC) with laser-induced fluorescence (LIF) detection has been developed for the determination of alpha-fetoprotein (AFP). The anti-AFP antibody was labeled with fluorescein isothiocyanate (FITC) and the product was used as a fluorescent tracer, then AFP was mixed with the labeled antibody. After incubation, the immune AFP-antibody complex was separated from labeled free antibody by MECC. The parameters affecting separation such as the concentration of sodium dodecyl sulfate (SDS), the buffer pH and separation voltage were investigated and the following conditions were selected: 20 mM tetraborate containing 100 mM SDS at pH 9.50, and 20 kV separation voltage. The detection limit of this assay was 0.1 ng/ml with a linear range spanning two orders of magnitude. This method was applied to determine AFP in human serum.  相似文献   

6.
Micellar electrokinetic chromatography is used to separate dansylated nucleotides, both normal and modified species. The high separation power allows detection of minor components present in less than 1 part per thousand of the major components. Laser-excited fluorescence is used to detect the separated components at the 6 · 10−18 mol level or 10−9 M injected material. Combined with high-performance liquid chromatographic enrichment prior to labeling, this technique can be used to assess DNA damage in carcinogenesis studies.  相似文献   

7.
8.
Sensitive capillary electrophoresis (CE) methods are required for emerging areas of biochemical research such as the metabolome. In this report, dynamic pH junction-sweeping CE with laser-induced fluorescence (LIF) detection is applied as a robust single method to analyze trace amounts of three flavin derivatives, riboflavin, flavin mononucleotide (FMN), and flavin adenine dinucleotide (FAD), from several types of samples including bacterial cell extracts, recombinant protein, and biological fluids. Submicromolar amounts of flavin coenzymes were measured directly from formic acid cell extracts of Bacillus subtilis. Significant differences in flavin concentration were measured in cell extracts derived from either glucose or malate as the carbon source in the culture media. Quantitative assessment of FAD and FMN content from selected flavoenzymes was demonstrated after heat denaturation to release noncovalently bound coenzymes and deproteinization. This method was also applied to the analysis of free flavins in pooled human plasma and urine without the need for laborious off-line sample preconcentration. Picomolar detectability of flavins by CE-LIF detection was realized with on-line preconcentration (up to 15% capillary length used for injection) by dynamic pH junction-sweeping, resulting in a limit of detection (S/N = 3) of about 4.0 pM for FAD and FMN. This represents over a 60-fold improvement in concentration sensitivity compared to those of previous techniques using conventional injections. The method was validated in terms of reproducibility, sensitivity, linearity, and specificity. Flavin analysis by dynamic pH junction-sweeping CE-LIF offers a simple, yet sensitive way to analyze trace levels of flavin metabolites from complex biological samples.  相似文献   

9.
The suitability of micellar electrokinetic capillary chromatography (MEKC) with laser-induced fluorescence (LIF) detection for the determination of pheomelanin in biological materials has been investigated. 5-Carboxyfluorescein succinimidyl ester was chosen as the labeling reagent to precapillary derivatize the two marker aminohydroxyphenylalanine (AHP) isomers produced after reductive hydrolysis of pheomelanin with hydriodic acid (HI). Various parameters affecting derivatization and separation were systematically studied. Under optimal conditions, the analytes could be separated within 18 min, and the relative standard deviations (R.S.D.) of migration time and corrected peak areas were less than 5.5%. Compared with the conventional high-performance liquid chromatography (HPLC) method with electrochemical detection, the 100-fold improvements in sensitivity were achieved by applying LIF detection. As a preliminary application, this method has been successfully applied to the determination of pheomelanin in two human melanoma cell cultures, black hair, melanoma tissue and urine samples of human melanoma patients with the spiked recoveries in the range of 88-96%.  相似文献   

10.
Capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) were used for the analysis of new synthetic derivatives of hypophysis neurohormones--vasopressin and oxytocin, and pancreatic hormone--human insulin (HI) and its octapeptide fragment, derivatized by fluorescent probe, 4-chloro-7-nitrobenzo[1,2,5]oxadiazol (NBD). The suitable composition of background electrolytes (BGEs) was selected on the basis of calculated pH dependence of effective charge of analyzed peptides. Basic ionogenic peptides were analyzed by CZE in the acidic BGE composed of 100 mM H3PO4, 50 mM Tris, pH 2.25. The ionogenic peptides with fluorescent label, NBD, were analyzed in 0.5 M acetic acid, pH 2.5. The best MEKC separation of non-ionogenic peptides was achieved in alkaline BGE, 20 mM Tris, 5 mM H3PO4, with micellar pseudophase formed by 50 mM sodium dodecylsulfate (SDS), pH 8.8. Selected characteristics (noise, detectability of substance, sensitivity of detector) of the UV-absorption detectors (single wavelength detector, multiple-wavelength photodiode array detector (PDA), both of them operating at constant wavelength 206 nm) and laser-induced fluorescence (LIF) detector (excitation/emission wavelength 488/520 nm) were determined. The detectability of peptides in the single wavelength detector was 1.3-6.0 micromol dm(-3) and in the PDA detector 1.6-3.1 micromol dm(-3). The LIF detection was more sensitive, the applied concentration of NBD derivative of insulin fragment in CZE analysis with LIF detection was three orders lower than in CZE with UV-absorption detector, and the detectability of this peptide was improved to 15.8 nmol dm(-3).  相似文献   

11.
The applicability of threshold logic units, a form of nonparametric pattern recognition, to the processing of metabolic profile data obtained by high-efficiency glass capillary column gas chromatography has been investigated. The test data included profiles of the volatile constituents of urine from normal individuals and from individuals with diabetes mellitus. A feature extraction algorithm allowed for dimensionality reduction and indicated the constituents most important in the normal versus pathological distinction. With an optimum number of dimensions, a normal versus pathological prediction rate of 93.75% was achieved. Gas chromatography—mass spectrometry was utilized to identify important profile constituents.  相似文献   

12.
13.
W Xiao  D Stern  M Jain  C G Huber  P J Oefner 《BioTechniques》2001,30(6):1332-1338
Denaturing high-performance liquid chromatography (DHPLC) is a sensitive, robust, and operationally inexpensive method for the detection of single-base substitutions and small deletions and insertions. To increase sample throughout, we have developed a multiplexing strategy using fluorophores to distinguish different PCR products. The system combines recent advances in the synthesis of monolithic poly(styrene-divinylbenzene) capillary columns with four-color confocal argon ion laser-induced fluorescence detection. Depending on the change in retention caused by the fluorophores, adjustments in the analysis temperature may be required to ensure the maximum mutation detection sensitivity.  相似文献   

14.
15.
A micellar electrokinetic capillary chromatography (MEKC) for determining fluoxetine and its metabolite (norfluoxetine) is proposed. Optimal conditions for the quantitative separation were investigated. A background electrolyte solution consisting of 5 mM phosphate buffer adjusted to pH 12.3 and 40 mM of 1-decanesulfonic acid sodium salt (DSS), hydrodynamic injection and 25 kV of separation voltage were used. Good linearity and precision were obtained for both compounds. Detection limits of 0.2 mg/l for fluoxetine and norfluoxetine were obtained. The developed method is rapid and it has been applied to determine fluoxetine and its metabolite in human serum and urine. The samples were purified and enriched by means of extraction-preconcentration step with a preconditioned C18 cartridge and eluting the compounds with methanol.  相似文献   

16.
This paper describes a simple and sensitive reversed-phase HPLC method for the determination of total homocysteine, total cysteine, total glutathione (GSH + GSSG), and neuroactive amino acids (Asp, Glu, Tau, GABA) using precolumn derivatization with ortho-phtaldialdehyde and fluorimetric detection at 360 and 470 nm for emission and excitation, respectively. Derivatization was performed with ortho-phthaldialdehyde in the presence of 2-mercaptoethanol after alkylation of free sulfhydryl groups with iodoacetic acid. For determination of total aminothiols, the disulfide bonds were reduced and protein-bound thiols were released by addition of dithiothreitol to the plasma sample. The advantage of this method is the simultaneous determination of both homocysteine/cysteine/glutathione and neuroactive amino acids in the sample. The plasma levels of studied compounds were determined in 14 healthy volunteers (20–45 years old) and 55 patients with chronic hepatitis C (20–49 years old) and the resulting values were in a good agreement with results published earlier. The calibration curves were linear over a concentration range of 5–100 μM in plasma (r 2 = 0.985−0.996). The intraday and interday coefficients of variation were 3–6% and 4–7%, respectively. The recovery of the standards added to the plasma samples ranged from 94 to 102%. The limits of detection (LOD) were 0.2–0.5 ng per 10 μl of the injection volume (signal-to-noise ratio of 3).  相似文献   

17.
A method was developed to analyze quantitatively free amino acids and amino acids attached to transfer RNA (tRNA) in tissue samples by gas chromatography. Free amino acids were purified by ion-exchange chromatography after deproteinization. Total cellular aminoacyl-tRNA was extracted from rabbit reticulocytes and liver by a modified phenol extraction method under conditions which were designed to prevent deacylation of the attached amino acids. After deacylation and separation from tRNA by pressure ultrafiltration, eighteen amino acids were determined by gas chromatography as their N-heptafluorobutyryl isobutyl derivatives.  相似文献   

18.
A simple specific assay was developed for the determination of acetaldehyde in biological samples. Acetaldehyde was derivatized to 2,4-dinitrophenylhydrazone, which was determined by gas chromatography with electron-capture detection. The use of this detection method is an important device to which no one drew notice. This procedure was very simple and so sensitive that as little as 500 fmol of acetaldehyde could be measured in aqueous solution. The calibration curve of acetaldehyde was linear at least up to 40 μM. Its recoveries from human plasma and rat liver homogenate were 96.5 and 95.7%, respectively.  相似文献   

19.
In order to determine propofol in rat whole-blood samples of 50 μl, we developed a rapid, simple and reliable method which is characterized by precipitation of blood elements with acetonitrile and submission of the supernatant to HPLC analysis with fluorescence detection. The method described is linear from 0.4 to 40 mg/l and the relative standard deviations in this concentration range are less than 10%. The limit of quantification proved to be 0.4 mg/l. Blood constituents do not interfere with the assay.  相似文献   

20.
The capillary electrophoresis (CE) system with optical fiber light-emitting diode (optical fiber LED) induced fluorescence detector was developed for the analysis of the excitatory amino acids (EAAs) tagged with naphthalene-2,3-dicarboxaldehyde (NDA). The separation of EAAs was carried out in an uncoated fused-silica capillary (50 cm x 75 microm i.d.) with a buffer of 10 mM borate at pH 9.3 and an applied voltage of 20 kV. High sensitivity was obtained by the use of optical fiber LED induced fluorescence detector with a violet LED as the excitation light source. The limits of detection (S/N = 3) for glutamic acid (Glu) and aspartic acid (Asp) were 2.1 x 10(-8) and 2.3 x 10(-8) M, respectively. The detection approach was successfully applied to the analysis of Glu and Asp in biological fluids including human serum, rabbit serum and human cerebrospinal fluid (CSF) with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号