首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel nucleic acid stain, SYBR Gold, was used to stain marine viral particles in various types of samples. Viral particles stained with SYBR Gold yielded bright and stable fluorescent signals that could be detected by a cooled charge-coupled device camera or by flow cytometry. The fluorescent signal strength of SYBR Gold-stained viruses was about twice that of SYBR Green I-stained viruses. Digital images of SYBR Gold-stained viral particles were processed to enumerate the concentration of viral particles by using digital image analysis software. Estimates of viral concentration based on digitized images were 1.3 times higher than those based on direct counting by epifluorescence microscopy. Direct epifluorescence counts of SYBR Gold-stained viral particles were in turn about 1.34 times higher than those estimated by the transmission electron microscope method. Bacteriophage lysates stained with SYBR Gold formed a distinct population in flow cytometric signatures. Flow cytometric analysis revealed at least four viral subpopulations for a Lake Erie sample and two subpopulations for a Georgia coastal sample. Flow cytometry-based viral counts for various types of samples averaged 1.1 times higher than direct epifluorescence microscopic counts. The potential application of digital image analysis and flow cytometry for rapid and accurate measurement of viral abundance in aquatic environments is discussed.  相似文献   

2.
Rapid fluorescence techniques were evaluated for the detection of bacterial contaminants in papermaking chemicals including starch and the resin-based sizes and starch slurries used in the paper industry. Viable and non-viable bacterial cells were visualised by fluorescent probes and detected by epifluorescence microscopy and flow cytometry. The best discrimination ability was obtained with the fluorescent probes LIVE/DEAD and SYBR Green, based on the staining of cellular nucleic acid, and ChemChrome V3, which demonstrated cellular enzymatic activity. The process samples had to be diluted and filtered before fluorescence staining and analysis because they were viscous and contained solid particles. Fluorescence microscopic counts of bacteria in highly contaminated process samples were similar to plate counts, but flow cytometric enumeration of bacterial cells in process samples yielded 2- to 10-fold lower counts compared with plate counts, depending on the consistency of the sample. The detection limits in flow cytometric analysis and in epifluorescence microscopy were 103–106 cells ml−1 and 105–106 cells ml−1, respectively. Intrinsic bacterial contamination was detectable with fluorescence techniques and highly contaminated process samples could be analysed with fluorescence methods. Electronic Publication  相似文献   

3.
Flow cytometry is now being used more frequently to determine sperm functional characteristics during semen assessment for artificial insemination. With this methodology, viable and potentially functional cells are detected as unstained events differentiated from non-sperm events through their light-scattering characteristics. However, it can be shown mathematically that identification of sperm on the basis of light scatter leads to significant overestimation of unstained viable cells and underestimation of responding cells in tests of sperm function (subpopulations expressing different fluorescence patterns). We have developed a simple and cost-efficient flow cytometric approach for identifying non-sperm particles that can be carried out in parallel with functional assessments. Our method is based on the sperm's osmotic intolerance. Diluted in water, lethal osmotic shock causes major damage to the cell membranes, and all sperm will stain with propidium iodide (PI). Particulate material which is not PI-positive can then be quantitatively evaluated by FACS analysis and the results substituted in mathematical equations to provide true values for sperm counts and subpopulations. In practical tests, the percentage of non-sperm particles determined by this technique was closely comparable to the figure obtained either by SYBR14®/PI staining or by PI/CFDA staining. As well as being valuable with respect to tests of sperm function, the procedure is also suitable for obtaining accurate sperm counts during routine semen evaluation.  相似文献   

4.
Determination of virus abundance in marine sediments   总被引:7,自引:0,他引:7  
In this study, we optimized procedures to enumerate viruses from marine sediments by epifluorescence microscopy using SYBR Green I as a stain. The highest virus yields from the bulk of the sediments were obtained by utilizing pyrophosphate and 3 min of sonication. The efficiency of extraction benthic viruses by pyrophosphate-ultrasound treatment was about 60% of the extractable virus particles. Samples treated with nucleases had increased virus counts, suggesting a masking effect of extracellular DNA. No significant differences were observed between virus counts obtained by epifluorescence microscopy and transmission electron microscopy. Both formaldehyde and glutaraldehyde gave significant reductions of virus counts after only 24 h of sediment storage, but no further loss occurred after 7 days.  相似文献   

5.
Determination of Virus Abundance in Marine Sediments   总被引:13,自引:4,他引:9       下载免费PDF全文
In this study, we optimized procedures to enumerate viruses from marine sediments by epifluorescence microscopy using SYBR Green I as a stain. The highest virus yields from the bulk of the sediments were obtained by utilizing pyrophosphate and 3 min of sonication. The efficiency of extraction benthic viruses by pyrophosphate-ultrasound treatment was about 60% of the extractable virus particles. Samples treated with nucleases had increased virus counts, suggesting a masking effect of extracellular DNA. No significant differences were observed between virus counts obtained by epifluorescence microscopy and transmission electron microscopy. Both formaldehyde and glutaraldehyde gave significant reductions of virus counts after only 24 h of sediment storage, but no further loss occurred after 7 days.  相似文献   

6.
AIMS: To develop a rapid and simple multicolour digital image analysis system for simultaneous identification of bacteria and assessment of their metabolic activity. METHODS AND RESULTS: We developed an image analyser capable of distinguishing triple-stained bacterial cells. Bacteria were stained with a nucleic acid stain, a fluorescent antibody and a fluorescent metabolic indicator for enumeration, species identification and assessment of metabolic activity. This multicolour image analyser was used to simultaneously identify Escherichia coli O157:H7 in milk samples and assess their respiratory activity. The images of the triple-stained bacteria were captured using a combination of blue light and u.v. excitation and an epifluorescence microscope and were processed by our image analyser. We found a good correlation between the counts of actively respiring (r = 0.93) and total (r = 0.94) E. coli O157:H7 measured by digital image analysis and visual observation. CONCLUSION: The multicolour digital image analysis system described here was able to quantify active pathogenic micro-organisms within 2 h. SIGNIFICANCE AND IMPACT OF THE STUDY: This multicolour image analysis allows the rapid and simultaneous quantification of bacteria, identification of species and assessment of metabolic activity.  相似文献   

7.
A method using an improved two-color flow cytometric analysis by a combination of bioconjugated fluorescent silica nanoparticles and SYBR Green I (FSiNP@SG-FCM) has been developed for detection of pathogenic Mycobacterium tuberculosis. Antibody-conjugated nanoparticles were prepared by oriented immobilization of the anti-M. tuberculosis antibody onto Tris(2,2-bipyridyl)dichlororuthenium(II) hexahydrate-doped fluorescent silica nanoparticles (RuBpy-doped FSiNPs) through Protein A. M. tuberculosis was specially labeled with antibody-conjugated RuBpy-doped FSiNPs, then stained with a nucleic acid dye SYBR Green I to exclude background detrital particles, followed by multiparameter determination with flow cytometry. With this method, false positives caused by aggregates of nanoparticle-bioconjugates and nonspecific binding of nanoparticle-bioconjugates to background debris could be significantly decreased. This assay allowed for detection of as low as 3.5 x 10(3) and 3.0 x 10(4)cellsml(-1)M. tuberculosis in buffer and spiked urine respectively, with higher sensitivities than the FITC-based conventional flow cytometry. The total assay time including sample pretreatment was within 2h. This proposed FSiNP@SG-FCM method will be promising for rapid detection of M. tuberculosis or other pathogenic bacteria in clinical samples.  相似文献   

8.
Viruses are the most abundant biological entities in aquatic environments, typically exceeding the abundance of bacteria by an order of magnitude. The reliable enumeration of virus-like particles in marine microbiological investigations is a key measurement parameter. Although the size of typical marine viruses (20-200 nm) is too small to permit the resolution of details by light microscopy, such viruses can be visualized by epifluorescence microscopy if stained brightly. This can be achieved using the sensitive DNA dye SYBR Green I (Molecular Probes-Invitrogen). The method relies on simple vacuum filtration to capture viruses on a 0.02-microm aluminum oxide filter, and subsequent staining and mounting to prepare slides. Virus-like particles are brightly stained and easily observed for enumeration, and prokaryotic cells can easily be counted on the same slides. The protocol provides an inexpensive, rapid (30 min) and reliable technique for obtaining counts of viruses and prokaryotes simultaneously.  相似文献   

9.
Traditionally, many cell-based assays that analyze cell populations and functionalities have been performed using flow cytometry. However, flow cytometers remain relatively expensive and require highly trained operators for routine maintenance and data analysis. Recently, an image cytometry system has been developed by Nexcelom Bioscience (Lawrence, MA, USA) for automated cell concentration and viability measurement using bright-field and fluorescent imaging methods. Image cytometry is analogous to flow cytometry in that gating operations can be performed on the cell population based on size and fluorescent intensity. In addition, the image cytometer is capable of capturing bright-field and fluorescent images, allowing for the measurement of cellular size and fluorescence intensity data. In this study, we labeled a population of cells with an enzymatic vitality stain (calcein-AM) and a cell viability dye (propidium iodide) and compared the data generated by flow and image cytometry. We report that measuring vitality and viability using the image cytometer is as effective as flow cytometric assays and allows for visual confirmation of the sample to exclude cellular debris. Image cytometry offers a direct method for performing fluorescent cell-based assays but also may be used as a complementary tool to flow cytometers for aiding the analysis of more complex samples.  相似文献   

10.
Flow cytometry (FCM) was successfully used to analyze freshwater bacteria and viruses in lake sediments after relatively simple sample treatment and optimization of dilution/fixation/staining procedures. Biological particles from Lakes Geneva and Bourget were first separated from the sediments by using both Sodium Pyrophosphate (0.01 M final concentration) and Polyoxyethylene-Sorbitan Monooleate (10% final concentration) and sonicating for 3 min in a water bath. The best results (based on FCM signature and the highest virus and bacterial yields from the sediments) were obtained by formaldehyde fixation carried out within less than one hour (2% final concentration, vs. no fixation or using glutaraldehyde at different concentrations), SYBR-Green II staining (x1/20,000 stock solution concentration, vs. use of SYBR-Gold and SYBR-Green I dyes at different concentrations). There was a considerable loss of particles after only a few days of storage at either 4 or -22 degrees C. For FCM analysis, the samples were diluted in Tris-EDTA buffer (pH 8) and heated for 10 min at 75 degrees C after incubating for 5 min in the dark. The bacterial and viral counts paralleled those obtained using epifluorescence microscopy (EFM), but EFM always gave lower counts than FCM. Analysis of the distribution of the viruses in the water column and in the sediments of Lakes Bourget revealed a marked gradient, with larger quantities in the top layer of the sediment than in the water above it. These results are discussed, as well as the possible novel application of flow cytometry in the study of aquatic viral ecology.  相似文献   

11.
The DNA-based human karyotype   总被引:4,自引:0,他引:4  
Image cytometry and computer analysis are used to determine the relative DNA content and the DNA-based centromeric index of the 24 chromosomes of the human karyotype. A two-step procedure is used. Chromosomes of cells in metaphase first are stained with quinacrine and identified visually by their fluorescent Q-band patterns. They then are stained for DNA using gallocyanin-chrome alum. The chromosome images are scanned and recorded as digital values of optical density by an CYDAC image cytometric microscope system, CYDAC. The digital images are processed by computer to measure for each chromosome the relative DNA stain contents of the whole chromosome and of the p and q arms and the DNA-based centromeric index. About ten cells are analyzed for each of the donors, who are phenotypically normal men and women. The chromosome measurements are pooled by chromosome type for each donor and are compared among donors. The means of the chromosome measurements give the DNA-based human karyotype. Analysis of the DNA-based data shows that some chromosomes or portions of chromosomes vary significantly among donors. These variants do not correlate with detectable morphologic polymorphisms, such as Q- or C-band variants; thus they represent new and otherwise undetectable chromosome polymorphisms whose genetic basis and clinical significance are yet to be determined.  相似文献   

12.
Bulk fluorescence measurements could be a faster and cheaper way of enumerating viruses than epifluorescence microscopy, flow cytometry, or transmission electron microscopy (TEM). However, since viruses are not imaged, the background fluorescence compromises the signal, and we know little about its nature. In this paper the size ranges of nucleotides that fluoresce in the presence of SYBR gold were determined for wastewater and a range of freshwater samples using a differential filtration method. Fluorescence excitation-emission matrices (FEEMs) showed that >70% of the SYBR fluorescence was in the <10-nm size fraction (background) and was not associated with intact viruses. This was confirmed using TEM. The use of FEEMs to develop a fluorescence-based method for counting viruses is an approach that is fundamentally different from the epifluorescence microscopy technique used for enumerating viruses. This high fluorescence background is currently overlooked, yet it has had a most pervasive influence on the development of a simple fluorescence-based method for quantifying viral abundance in water.  相似文献   

13.
Spermatozoa from bulls, boars, dogs, horses, mice, and men were examined using a fluorogenic stain consisting of the membrane-permeant substrate carboxyfluorescin diacetate (CFDA) and the relatively membrane-impermeant nuclear stain propidium iodide (PI). Three distinct populations of spermatozoa were discernible in samples from each species upon microscopic examination. Individual spermatozoa, presumed to be viable because of their motility, retained products of the fluorescein chromophore throughout the cell. A second population of spermatozoa in which the nuclei stained red with PI retained the green fluorescein fluorophore mainly in the acrosome. A third population, presumed to be degenerate spermatozoa, possessed only red fluorescent nuclei. These populations were quantified using dual parameter flow cytometry in 14 samples of cryopreserved bovine spermatozoa for which fertility and seminal quality data were available. Flow cytometric analyses were highly correlated with other seminal quality measurements. Sequential flow cytometric analyses provided the ability to rapidly quantitate changes in specific fluorescently stained populations. The ability to make rapid quantitative measurements should allow development of new and presumably more reliable information on the functional aspects of spermatozoa.  相似文献   

14.
A rapid, simple, and reliable flow cytometric method using the histochemical fluorescent stain Hoechst 33342 in presence of the non-ionic detergent Triton X-100 has been reported. The processing of melanoma cell cultures to get nuclei stained with the fluorescent dye was accomplished in one step and within an hour permitted concurrent flow cytometric measurement of cell density and cell cycle analysis. The preparation is stable for more than three weeks at room temperature for flow cytometry. The histograms are reproducible and exhibit a coefficient of variation of less than 2.5% (G1 peak). The cell density measurements varied within +/- 5% limits.  相似文献   

15.
Flow cytometric analysis of Chlamydia trachomatis interaction with L cells   总被引:2,自引:0,他引:2  
Immunofluorescent staining and flow cytometric analysis have been investigated as means of studying the early stages of in vitro infection of Chlamydia trachomatis. The lymphogranuloma venereum strain of C. trachomatis was grown in vitro in L cells, fixed in p-formaldehyde, stained with fluorescein isothiocyanate (FITC)-conjugated monoclonal antibody to the chlamydial major outer membrane protein, and analyzed flow cytometrically. Infected cells stained 50-100 times more intensely than uninfected cells, and they could easily be discriminated by flow analysis. The number of infected cells and the fluorescence intensity of individual cells were proportional to the multiplicity of infection. The attachment of purified elementary bodies to L cells could be analyzed by immunofluorescence and flow cytometry. Cells exposed to 0.26 inclusion-forming units/cell could be discriminated from an unexposed population. Flow analysis of purified elementary bodies was possible after fluorescent staining with the aid of a laser-based cytometer and gating on low volume.  相似文献   

16.
The nucleic acid contents of individual bacterial cells as determined with three different nucleic acid-specific fluorescent dyes (SYBR I, SYBR II, and SYTO 13) and flow cytometry were compared for different seawater samples. Similar fluorescence patterns were observed, and bacteria with high apparent nucleic acid contents (HNA) could be discriminated from bacteria with low nucleic acid contents (LNA). The best discrimination between HNA and LNA cells was found when cells were stained with SYBR II. Bacteria in different water samples collected from seven freshwater, brackish water, and seawater ecosystems were prelabeled with tritiated leucine and then stained with SYBR II. After labeling and staining, HNA, LNA, and total cells were sorted by flow cytometry, and the specific activity of each cellular category was determined from leucine incorporation rates. The HNA cells were responsible for most of the total bacterial production, and the specific activities of cells in the HNA population varied between samples by a factor of seven. We suggest that nucleic acid content alone can be a better indicator of the fraction of growing cells than total counts and that this approach should be combined with other fluorescent physiological probes to improve detection of the most active cells in aquatic systems.  相似文献   

17.
Flow cytometry (FCM) was successfully used to enumerate viruses in seawater after staining with the nucleic acid-specific dye SYBR Green-I. The technique was first optimized by using the Phaeocystis lytic virus PpV-01. Then it was used to analyze natural samples from different oceanic locations. Virus samples were fixed with 0.5% glutaraldehyde and deep frozen for delayed analysis. The samples were then diluted in Tris-EDTA buffer and analyzed in the presence of SYBR Green-I. A duplicate sample was heated at 80°C in the presence of detergent before analysis. Virus counts obtained by FCM were highly correlated to, although slightly higher than, those obtained by epifluorescence microscopy or by transmission electron microscopy (r = 0.937, n = 14, and r = 0.96, n = 8, respectively). Analysis of a depth profile from the Mediterranean Sea revealed that the abundance of viruses displayed the same vertical trend as that of planktonic cells. FCM permits us to distinguish between at least two and sometimes three virus populations in natural samples. Because of its speed and accuracy, FCM should prove very useful for studies of virus infection in cultures and should allow us to better understand the structure and dynamics of virus populations in natural waters.  相似文献   

18.
The nucleic acid contents of individual bacterial cells as determined with three different nucleic acid-specific fluorescent dyes (SYBR I, SYBR II, and SYTO 13) and flow cytometry were compared for different seawater samples. Similar fluorescence patterns were observed, and bacteria with high apparent nucleic acid contents (HNA) could be discriminated from bacteria with low nucleic acid contents (LNA). The best discrimination between HNA and LNA cells was found when cells were stained with SYBR II. Bacteria in different water samples collected from seven freshwater, brackish water, and seawater ecosystems were prelabeled with tritiated leucine and then stained with SYBR II. After labeling and staining, HNA, LNA, and total cells were sorted by flow cytometry, and the specific activity of each cellular category was determined from leucine incorporation rates. The HNA cells were responsible for most of the total bacterial production, and the specific activities of cells in the HNA population varied between samples by a factor of seven. We suggest that nucleic acid content alone can be a better indicator of the fraction of growing cells than total counts and that this approach should be combined with other fluorescent physiological probes to improve detection of the most active cells in aquatic systems.  相似文献   

19.
BACKGROUND: Although the infection of Theileria sergenti is demonstrated by intraerythrocytic localization of this parasite, much time and labor are necessary in order to determine this. We applied flow cytometry to evaluate T. sergenti parasitemia using the fluorescent nucleic acid stain method. METHODS: Peripheral blood samples from cattle infected with T. sergenti were stained with a membrane-permeable fluorescent nucleic acid stain, SYTO16, and hydroethidine (HE). Stained parasitized erythrocytes were measured by a flow cytometer equipped with a single argon laser operating at 488 nm. RESULTS: SYTO16-stained intraerythrocytic parasites were detected on the FL1 (525 nm) and parasitized cells were separated completely from unparasitized cells. However, HE-stained erythrocytes could not be divided clearly into parasitized and unparasitized cells. SYTO16-stained parasites were reproducibly detected at a percentage above 0.1%. Contaminating leukocytes, which were indicated by CD18-positive cells, were eliminated from the analysis by narrowing the light scatter gate of the erythrocyte fraction. A correlation (r = 0.983) between the percentage of SYTO16-positive cells and parasitemia in grazing cattle was observed. CONCLUSIONS: Flow cytometric detection using SYTO16 is a rapid and reliable method of monitoring parasitemia in T. sergenti-infected cattle.  相似文献   

20.
Cytochemical studies of metaphase chromosomes by flow cytometry   总被引:10,自引:0,他引:10  
The cytochemical properties of metaphase chromosomes from Chinese hamster and human cells were studied by flow cytometry. This technique allows precise quantitation of the fluorescence properties of individual stained chromosome types. Chromosomes were stained with the following fluorescent DNA stains: Hoechst 33258, DAPI, chromomycin A3, ethidium bromide, and propidium iodide. The relative fluorescence of individual chromosome types varied depending on the stain used, demonstrating that individual chromosome types differ in chemical properties. Flow measurements were performed as a function of stain and chromosome concentration to characterize the number and distribution of stain binding sites. Flow analysis of double stained chromosomes show that bound stains interact by energy transfer with little or no binding competition. For most hamster chromosomes, there is a strong correlation between relative fluorescence and stain base preference suggesting that staining differences may be determined primarily by differences in average base composition. A few hamster chromosome types exhibit anomalous staining which suggests that some other property, such as repetitive DNA sequences, also may be an important determinant of chromosomal staining.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号