首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Multicolumn capture chromatography is gaining increased attention lately due to the significant economic and process advantages it offers compared with traditional batch mode chromatography. However, for wide adoption of this technology in clinical and commercial space, it requires scalable models for executing viral validation studies. In this study, viral validation studies were conducted under cGLP guidelines to assess retro- (X-MuLV) and parvo-virus (MVM) clearance across twin-column continuous capture chromatography (CaptureSMB). A surrogate model was also developed using standard batch mode chromatography based on flow path modifications to mimic the loading strategy used in CaptureSMB. The results show that a steady state was achieved by the second cycle for both antibody binding and virus clearance and that the surrogate model using batch mode chromatography equipment provided impurity clearance that was comparable to that obtained during cyclical operation of CaptureSMB. Further, the log reduction values (LRVs) achieved during CaptureSMB were also comparable to the LRVs obtained using standard batch capture chromatography. This was expected since the mode of virus separation during protein A chromatography is primarily based on removal during the flow through and wash steps. Finally, this study also presents assessments on the resin cleaning strategy during continuous chromatography and how the duration of clean-in-place solution exposure impacts virus carryover.  相似文献   

2.
A commercially available system for microbial identification by fatty acid analysis (Microbial Identification System (MIS), MIDI, Newark, DE, USA) requires a four-step sample derivatization procedure in screw-cap test tubes. By using glass tubes in a 96-well format with multichannel pipetting, the time required for sample preparation can be greatly reduced. The standard gas chromatography column, 25 m long by 0.20 mm ID, is replaced with a 10 m long by 0.10 mm ID column, reducing the gas chromatography run time to one third of the standard time. Either or both of these procedures can be easily implemented in any laboratory using the MIDI system, resulting in faster identifications and higher sample throughput.  相似文献   

3.
A discharge-assisted thermospray liquid chromatography/mass spectrometric method for the determination of serum glucose was studied. Isotope dilution technique was used with uniformly labelled (13C6) glucose as an internal standard. Successful liquid chromatography/mass spectrometry was achieved by post-column addition of aqueous ammonium acetate to the mobile phase. Quantification was performed by measuring the peak intensity ratios of the unlabelled and labelled [M + NH4]+ ions. Analytical results using the National Institute of Standards and Technology standard reference material serum showed satisfactory agreement with the certified value, and a relative standard deviation of about 1% was obtained.  相似文献   

4.
比较重组人粒细胞-巨噬细胞集落刺激因子(rhGM-CSF)在用疏水色谱(HIC)、离子交换色谱(IEC)和体积排阻色谱(SEC)3种液相色谱进行复性和纯化,选择较好的复性和纯化方法.通过对比rhGM-CSF在液相色谱上复性和纯化的主要指标,包括比活、纯度和质量回收率,结果发现采用HIC和IEC对rhGM-CSF进行复性和纯化时,其比活可以达到国家标准,纯度和质量回收率也比较高,而采用SEC,其比活、纯度和质量回收率远低于HIC和IEC.  相似文献   

5.
采用壳聚糖固定酶作用的特定底物(菌体细胞),并用戊二醛交联制备成酶的亲和吸附剂。采用该吸附剂纯化溶葡球菌的研究表明,经一步纯化可提高纯度4倍,酶活性回收大于70%。SDS-PAGE的电泳结果显示,产品基本上达到了标准酶的纯度。同时表明该吸附剂没有非特异性吸附。由载体壳聚糖替代Sepharose 4B制备的吸附剂具有简单、快速、较高收得率和操作安全等优点,适用于特定酶或基因工程产品的分离纯化。  相似文献   

6.
11 alpha-Hydroxy-9,15-dioxo-2,3,4,5,20-pentanor-19-carboxyprostano ic acid (PGE-M) and 9 alpha,11 alpha-dihydroxy-15-oxo-2,3,4,5,20-pentanor-19-carboxyprostanoic acid (PGF-M) in urine were determined in an isotope dilution assay by gas chromatography/triple-stage quadrupole mass spectrometry. After addition of the 2H7-labeled internal standard, O-methylhydroxylamine hydrochloride in acetate buffer was added either directly (PGE-M) or after standing overnight at pH 10 (PGF-M) to form the methoxime. The sample was acidified to pH 2.5 and PGE-M and PGF-M were extracted with ethyl acetate/hexane. Then the prostanoids were derivatized to the pentafluorobenzyl ester and purified by thin-layer chromatography and the trimethylsilyl ether was formed. The products were quantified by gas chromatography/triple-stage quadrupole mass spectrometry. For PGE-M, the fragment ions m/z 349 and m/z 356 (2H7 standard) (daughter ions of m/z 637 and m/z 644 (2H7 standard] were used. The results of the PGE-M assay were compared with those of an assay using the [2H3]methoxime as the internal standard. For determination of PGF-M, the daughter ions m/z 484 and m/z 491 (2H7 standard) with the parent ions m/z 682 and m/z 689 (2H7 standard) were chosen.  相似文献   

7.
A rapid and sensitive method for quantitative determination of three bile lipid components, cholesterol, bile acids, and lecithin, is described. These components were separated by thin-layer chromatography on a silica gel plate, spots were visualized with a phosphomolybdate reagent, and their color intensities were estimated by direct densitometry using a dualwavelength chromatoscanner. The lithogenic index was estimated by the molar ratio of the three lipids. This method can be applied to the routine analysis of bile in patients with gallstones. It has been evaluated by comparison with the method using standard gas-liquid chromatography and spectrophotometry.  相似文献   

8.
A membrane protein that specifically binds the insect neuropeptide proctolin was purified using standard chromatography from cockroach foregut membranes. Proctolin-binding sites were efficiently solubilized with either the nonionic detergent digitonin or the zwitterionic detergent Chaps, as indicated by the specific binding of 3H-proctolin to solubilized samples. A solubilized sample obtained from 1600 foregut membranes was subjected to a five-step chromatographic purification including chromatofocusing, anion-exchange and size-exclusion chromatographies. The final size-exclusion separation resulted in the isolation of approximately 100 pmol of purified proctolin-binding proteins, eluting as a single peak at approximately 74 kDa. Analysis of the purified sample using SDS/PAGE and silver staining showed two bands at 80 kDa and 76 kDa. Densitometric analysis of the gel indicated that each band contained approximately 7-8 microg of protein, suggesting that one band corresponds to the proctolin-binding activity. Proctolin-binding proteins were thus purified 1800-fold using standard chromatography.  相似文献   

9.
Quantitative levels of indole-3-acetic acid (IAA) were determined in leaf blades of two sugarbeet cultivars by a double standard isotope dilution assay using column chromatography followed by reverse phase C18 high performance liquid chromatography and gas-liquid chromatography with nitrogen thermionic detection. The double standard method was validated as a quantitative tool by gas chromatography/selected ion monitoring mass spectrometry using 2,′,4′,5′,6′,7′-d5-IAA as the internal standard. Progenies of one breeding line that had been selected for a high taproot to leaf weight ratio were used to correlate IAA levels with varying leaf and plant size at day 31 from germination. In spite of size differences, no significant difference in IAA levels per unit leaf weight could be found. The possible relationship between day 31 leaves and IAA content at an earlier stage of development is discussed in the text. A second analysis used four developmental leaf stages, classified as expanding, recently mature, aging, and senescing leaves. Expanding leaves contained the most IAA, senescing leaves contained the least IAA, with recently mature leaves and aging leaves containing intermediate amounts. The DNA content of each of the four developmental leaf stages was determined and DNA levels per gram fresh weight were found to be constant at all developmental stages.  相似文献   

10.
An affinity chromatography method was developed for the purification of hygromycin B from biological fluids. Lysozyme and α-lactalbumin were immobilized on an N-hydroxysuccinimide activated agarose support. Hygromycin B solubilized in water was bound by the proteins and subsequently eluted using 10 mM sodium citrate buffer, pH 4.0. Hygromycin B was purified from swine plasma, bovine serum and bovine milk samples using a combination of ion-exchange chromatography for initial clean-up of spiked biological samples followed by affinity chromatography. Thin layer chromatographic analysis of the isolated hygromycin B revealed one band with the same RF value as the hygromycin B standard.  相似文献   

11.
层析法去除A群流脑多糖疫苗粗糖中杂蛋白   总被引:1,自引:0,他引:1  
目的:建立用层析法去除脑脊髓膜炎球菌A群荚膜多糖样品中的杂蛋白的方法,以替代传统的苯酚抽提。方法:A群流脑多糖粗糖经过新型多模式离子交换填料Capto adhere,使用低盐上样高盐洗脱,洗脱的目的峰再经过Sephardex G-25凝胶过滤脱盐换成水,即为流脑多糖精糖原液。结果:采用上述方法制备的精制多糖样品中杂蛋白占固总的比例低于0.2%,符合WHO现行规程中的杂蛋白比例低于1%的要求,核酸、内毒素等生化指标均符合现行规程,整个层析过程的回收率大于65%。结论:层析法去除A群流脑多糖粗糖中的杂蛋白是有效的,比传统的苯酚抽提的方法更有利于环保,易于操作,易于放大。  相似文献   

12.
We present a miniaturized pull-down method for the detection of protein-protein interactions using standard affinity chromatography reagents. Binding events between different proteins, which are color-coded with quantum dots (QDs), are visualized on single affinity chromatography beads by fluorescence microscopy. The use of QDs for single molecule detection allows the simultaneous analysis of multiple protein-protein binding events and reduces the amount of time and material needed to perform a pull-down experiment.  相似文献   

13.
A test for determining N-acetylator metabolic phenotype has been developed using caffeine as a probe drug. A spot sample of urine is taken, and the unextracted urine is then analysed by micellar electrokinetic capillary chromatography. Phenotype is determined from the peak-area ratio of urinary 5-acetylamino-6-formylamino-3-methyluracil to 1-methylxanthine. Phenotype assignments using this method were compared with those made using a standard high-performance liquid chromatography assay, with good agreement between the two methods. The advantage of the capillary electrophoresis analysis is that no sample extraction is necessary, resulting in a total analysis time of around 20 min, and removing a potential source of error.  相似文献   

14.
Displacement chromatography is a predominantly nonlinear mode of chromatography, which has certain advantages over the elution mode for preparative bioseparations. Whereas continuous production (and separation) processes have their theoretical benefits in this context, protein displacement chromatography has up to now only been performed in the batch mode. In this contribution, we demonstrate that the principle of continuous annular chromatography can be adapted to displacement chromatography. Separations of up to three standard proteins (two whey proteins, soybean trypsin inhibitor) were developed and optimized using a small (4 x 250 mm) batch column. These separations were subsequently transferred directly to the continuous system (500-mL column). Separations of similar quality in terms of final product purity and recovery yield were obtained using the continuous system.  相似文献   

15.
A method for the determination of therapeutic levels of metoprolol in human plasma is presented. Metoprolol and the internal standard are extracted from the buffered plasma sample to an organic phase containing 4 x 10?3M phosgene. After 10 min the organic phase is taken to dryness. The residue is dissolved in ethyl acetate and the formed oxazolidine derivatives are analyzed by gas chromatography with nitrogen-selective detection. With packed columns, rectilinear standard curves through the origin were obtained down to 80 nmoles/l of plasma. The precision of the method at 200 nmoles/l was 1.5% (n = 8). The sensitivity of the method was improved by using capillary column gas chromatography. Linear standard curves were obtained down to 10 nmoles/1 of metoprolol in plasma. The precision of the method at the 50 nmoles/1 level was 2.2% (n = 7). With this simple and straightforward method using extractive derivatization 30 samples can be handled in a day.  相似文献   

16.
Kim S  Kim HJ 《Bioresource technology》2005,96(13):1457-1464
Formaldehyde emissions from MDF bonded with urea-formaldehyde resin (UF), melamine-formaldehyde resin (MF) and the co-polycondensation resin of urea-melamine-formaldehyde (UMF) and melamine-formaldehyde, measured by the Japanese standard method of determining formaldehyde emission with a desiccator (JIS A 5908) and the DIN EN 120 (European Committee For Standardization, 1991) method using the perforator value, were used as the typical standard methods. While the UF resin showed a desiccator value of 7.05 ppm and a perforator value of 12.1 mg/100 g panel, the MF resin exhibited a desiccator value of 0.6 ppm and a perforator value of 2.88 mg/100 g panel. According to the Japanese industrial standard and the European standard, the formaldehyde emission level of the MDF panels made with UF resin in this study was E(2) grade. The formaldehyde emission level was dramatically reduced by the addition of MF resin. This is because the addition of formaldehyde to melamine occurs more easily and completely than its addition to urea, even though the condensation reaction of melamine with formaldehyde is similar to that between urea and formaldehyde. These two methods, the desiccator method and the perforator method, produced proportionally equivalent results. Gas chromatography, a more sensitive and advanced method, was also used. The samples used for gas chromatography were gathered during the experiment involving the perforator method. The formaldehyde emission levels obtained from gas chromatography were similar to those obtained from the perforator method. The formaldehyde contents measured by gas chromatography were directly proportional to the perforator values.  相似文献   

17.
This study used a combination of zonal elution and frontal affinity chromatography on immobilized human serum albumin (HSA) high-performance affinity chromatography (HPAC) column to examine the association constants of various compounds that have been studied by equilibrium dialysis or ultra filtration. A standard plot was generated from retention factors of reference compounds using zonal elution chromatography against association constants of reference compounds using frontal affinity chromatography. The linear relationship was established (r2=0.9993) between retention factors and association constants of reference compounds. This standard plot was later used for rapid determination of association constants of various drugs which show low to medium binding affinity to HSA. Association constants of those drugs from this study were compared to that of more generally used methods (i.e., equilibrium dialysis or ultra filtration) from literature and resulted in a relatively high correlation (r2=0.945) value. This combination of zonal elution and frontal affinity chromatography method for determining association constants showed several advantages against traditional methods. Depending on drugs of interest, an association constant of drug to HSA can be measured as fast as 1.5 min. Other notable advantages include an ease of automation and its ability to distinguish association constants of chiral compounds at the same time. The same approach could be used for studying interaction of other drugs and proteins and should further improve overall drug screening process.  相似文献   

18.
An assay was developed for the quantification of anastrozole [2,2′-[5-(1H-1,2,4-triazol-1-ymethyl)-1,3-phenylene]bis(2-methylpropiononitrile)] in human plasma using liquid-liquid extraction. Anastrozole and an internal standard were chromatographed and detected by gas chromatography with electron capture detection, using a combination temperature-pressure program. The range of the assay is 3 to 100 ng/ml. Anastrozole was quantified by comparing its peak area to that of an internal standard. A cross-validation of this assay was also successfully performed between several laboratories.  相似文献   

19.
Isotope dilution analysis for the quantitation of labile compounds has been limited in applicability by the amount of sample necessary to determine specific activity. A method is described for the analysis of radiolabeled compounds which allows the direct determination of specific activity by gas chromatography. It requires the availability of the radiolabeled internal standard, as is customarily used in an isotope dilution assay, and also requires a chemically related radiolabeled compound to serve as a second internal standard. It is this second internal standard, added in known amounts, that permits quantitation of the gas chromatography. The method is illustrated by assaying indole-3-acetic acid in plant extracts using [14C]indole-3-acetic acid as the internal standard and adding [14C]indole-3-butyric acid as the second internal standard for quantitation of the gas chromatographic procedures. Used with a nitrogen-specific thermionic detector the method is selective and is sensitive at the nanogram level. The synthesis of [2-ring-14C]indole-3-butyric acid is also described.  相似文献   

20.
An assay using nonsuppressed (single-column) anion chromatography was developed to determine the concentration of inorganic sulfate in biologic fluids. A conventional HPLC system with an anion-exchange column and conductimetric detector interfaced with an automatic injector and integrator was used. The mobile phase for the chromatography of urine and serum samples is 4 mM potassium hydrogen phthalate, pH 4.5, and potassium iodide is used as the internal standard. For cerebrospinal fluid samples, the mobile phase is modified by addition of 10% of a 4 mM phthalic acid solution. Results of the HPLC assay were found to correlate well (r = 0.991 and 0.999) with those of two commonly used spectrophotometric methods for urine and serum inorganic sulfate determinations. However, the concentrations determined by ion chromatography were 2.5 to 10% lower, possibly due to less assay interference by other substances following chromatographic separation of sulfate. Anion chromatography using a single-column system is a convenient and relatively inexpensive method with sufficient sensitivity for the determination of inorganic sulfate concentrations in urine, serum, and cerebrospinal fluid.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号