首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Specific binding of the anticoagulants heparin and antithrombin III to the blood clotting cascade factor human thrombin was recorded as a function of time with a Love-wave biosensor array consisting of five sensor elements. Two of the sensor elements were used as references. Three sensor elements were coated with RNA or DNA aptamers for specific binding of human thrombin. The affinity between the aptamers and thrombin, measured using the biosensor, was within the same range as the value of K(D) measured by filter binding experiments. Consecutive binding of the thrombin inhibitors heparin, antithrombin III or the heparin-antithrombin III complex to the immobilized thrombin molecules, and binding of a ternary complex of heparin, anithrombin III, and thrombin to aptamers was evaluated. The experiments showed attenuation of binding to thrombin due to heparin-antithrombin III complex formation. Binding of heparin activated the formation of the inhibitory complex of antithrombin III with thrombin about 2.7-fold. Binding of the DNA aptamer to exosite II appeared to inhibit heparin binding to exosite I.  相似文献   

2.
A novel strategy for the fabrication of an electrochemical aptasensor is proposed; this strategy has been employed in this work to assay thrombin concentration. Two well-designed oligonucleotides were used as the core element. G-quadruplex–hemin complexes can be formed on the surface of the electrode to give a detectable signal only when thrombin is not bound to the aptamers. The detection limit of the biosensor has been lowered to 10 nM. Moreover, since the electroactive probe is not required to be bound to the oligonucleotide, this strategy may integrate the advantages of being both label-free and cost-effective.  相似文献   

3.
The fabrication of DNA origamis is one of the very few possibilities to create nanostructures with precise atomistic-tailored geometries in a variety of shapes. In addition, these origamis can be functionalized or be impregnated with specialised aptamers in order to convert them into nanosensors or to tune them with pre-specified properties simply by impregnating single-stranded DNA or RNA chains (aptamers) via the precise features of DNA pairing. We performed molecular dynamics simulations to determine the relative energetics associated with the capture of thrombin by two aptamers TBA26 and TBA29 attached to a rectangular DNA origami. The molecular simulations provided detailed structural information of aptamer–enzyme interactions which are crucial for the efficient design of aptamer-based biosensors. In addition, the simulations showed a remarkable selectivity of the biosensor assembly for thrombin. The detection, capture, and sensing of enzymes is of great significance in biomedicine. In particular, the detection of thrombin is a major task in cardiovascular diagnostics and therapeutics. On the other hand, our simulations can be extended to detect biotoxins or any other chemical or biological agent by simply choosing proper aptamers. Finally, the problems due to the large number of atoms involved as well as the quality of the approximations are also discussed.  相似文献   

4.
Li X  Shen L  Zhang D  Qi H  Gao Q  Ma F  Zhang C 《Biosensors & bioelectronics》2008,23(11):1624-1630
A simple and highly sensitive electrochemical impedance spectroscopy (EIS) biosensor based on a thrombin-binding aptamer as molecular recognition element was developed for the determination of thrombin. The signal enhancement was achieved by using gold nanoparticles (GNPs), which was electrodeposited onto a glassy carbon electrode (GCE), as a platform for the immobilization of the thiolated aptamer. In the measurement of thrombin, the change in interfacial electron transfer resistance of the biosensor using a redox couple of [Fe(CN)6]3−/4− as the probe was monitored. The increase of the electron transfer resistance of the biosensor is linear with the concentration of thrombin in the range from 0.12 nM to 30 nM. The association and dissociation rate constants of the immobilized aptamer–thrombin complex were 6.7 × 103 M−1 s−1 and 1.0 × 10−4 s−1, respectively. The association and dissociation constants of three different immobilized aptamers binding with thrombin were measured and the difference of the dissociation constants obtained was discussed. This work demonstrates that GNPs electrodeposited on GCE used as a platform for the immobilization of the thiolated aptamer can improve the sensitivity of an EIS biosensor for the determination of protein. This work also demonstrates that EIS method is an efficient method for the determination of association and dissociation constants on GNPs modified GCE.  相似文献   

5.
Traditional methods for selecting aptamers require multiple rounds of selection and optimization in order to identify aptamers that bind with high affinity to their targets. Here we describe an assay that requires only one round of positive selection followed by high-throughput DNA sequencing and informatic analysis in order to select high-affinity aptamers. The assay is flexible, requires less hands on time, and can be used by laboratories with minimal expertise in aptamer biology to quickly select high-affinity aptamers to a target of interest. This assay has been utilized to successfully identify aptamers that bind to thrombin with dissociation constants in the nanomolar range.  相似文献   

6.
Immunomagnetic DNA aptamer assay   总被引:2,自引:0,他引:2  
Rye PD  Nustad K 《BioTechniques》2001,30(2):290-2, 294-5
DNA aptamers, oligonucleotides with antibody-like binding properties, are easy to manufacture and modify. As a class of molecules, they represent the biggest revolution to immunodiagnostics since the discovery of monoclonal antibodies. To demonstrate that DNA aptamers are versatile reagents for use as in vitro diagnostic tools, we developed a hybrid immunobead assay based on a 5'-biotinylated DNA thrombin aptamer (5'-GGTTGGTGTGGTTGG-3') and an anti-thrombin antibody (EST-7). Our results show that the thrombin DNA aptamer is capable of binding to its target molecule under stringent in vitro assay conditions and at physiological concentrations. These findings also support the view that DNA aptamers have potential value as complementary reagents in diagnostic assays.  相似文献   

7.
Atomic force microscopy (AFM) can detect the adhesion or affinity force between a sample surface and cantilever, dynamically. This feature is useful as a method for the selection of aptamers that bind to their targets with very high affinity. Therefore, we propose the Systematic Evolution of Ligands by an EXponential enrichment (SELEX) method using AFM to obtain aptamers that have a strong affinity for target molecules. In this study, thrombin was chosen as the target molecule, and an ‘AFM-SELEX’ cycle was performed. As a result, selected cycles were completed with only three rounds, and many of the obtained aptamers had a higher affinity to thrombin than the conventional thrombin aptamer. Moreover, one type of obtained aptamer had a high affinity to thrombin as well as the anti-thrombin antibody. AFM-SELEX is, therefore, considered to be an available method for the selection of DNA aptamers that have a high affinity for their target molecules.  相似文献   

8.
Multivalent circular aptamers or ‘captamers’ have recently been introduced through the merger of aptameric recognition functions with the basic principles of DNA nanotechnology. Aptamers have strong utility as protein-binding motifs for diagnostic applications, where their ease of discovery, thermal stability and low cost make them ideal components for incorporation into targeted protein assays. Here we report upon a property specific to circular DNA aptamers: their intrinsic compatibility with a highly sensitive protein detection method termed the ‘proximity extension’ assay. The circular DNA architecture facilitates the integration of multiple functional elements into a single molecule: aptameric target recognition, nucleic acid hybridization specificity and rolling circle amplification. Successful exploitation of these properties is demonstrated for the molecular analysis of thrombin, with the assay delivering a detection limit nearly three orders of magnitude below the dissociation constants of the two contributing aptamer–thrombin interactions. Real-time signal amplification and detection under isothermal conditions points towards potential clinical applications, with both fluorescent and bioelectronic methods of detection achieved. This application elaborates the pleiotropic properties of circular DNA aptamers beyond the stability, potency and multitargeting characteristics described earlier.  相似文献   

9.
A fiber-optic microarray biosensor using aptamers as receptors   总被引:7,自引:0,他引:7  
A fiber-optic biosensor using an aptamer receptor has been developed for the measurement of thrombin. An antithrombin DNA aptamer was immobilized on the surface of silica microspheres, and these aptamer beads were distributed in microwells on the distal tip of an imaging fiber. A different oligonucleotide bead type prepared using the same method as the aptamer beads was also included in the microwells to measure the degree of nonspecific binding. The imaging fiber was coupled to a modified epifluorescence microscope system, and the distal end of the fiber was incubated with a fluorescein-labeled thrombin (F-thrombin) solution. Nonlabeled thrombin could be detected using a competitive binding assay with F-thrombin. The aptamer beads selectively bound to the target and could be reused without any sensitivity change. The fiber-optic microarray system has a detection limit of 1 nM for nonlabeled thrombin, and each test can be performed in ca. 15 min including the regeneration time.  相似文献   

10.
以分子信标为报告分子,核酸适体为识别分子,发展了一种新的凝血酶检测方法.含有分子信标互补序列的核酸适体探针与凝血酶结合后,分子信标的荧光信号下降,从而得到凝血酶的浓度信息.该方法快速、灵敏,核酸适体探针无需荧光标记、设计简单,检测限达到0.83nmol/L.  相似文献   

11.

Background

The accuracy and precision of estimates of DNA concentration are critical factors for efficient use of DNA samples in high-throughput genotype and sequence analyses. We evaluated the performance of spectrophotometric (OD) DNA quantification, and compared it to two fluorometric quantification methods, the PicoGreen® assay (PG), and a novel real-time quantitative genomic PCR assay (QG) specific to a region at the human BRCA1 locus. Twenty-Two lymphoblastoid cell line DNA samples with an initial concentration of ~350 ng/uL were diluted to 20 ng/uL. DNA concentration was estimated by OD and further diluted to 5 ng/uL. The concentrations of multiple aliquots of the final dilution were measured by the OD, QG and PG methods. The effects of manual and robotic laboratory sample handling procedures on the estimates of DNA concentration were assessed using variance components analyses.

Results

The OD method was the DNA quantification method most concordant with the reference sample among the three methods evaluated. A large fraction of the total variance for all three methods (36.0–95.7%) was explained by sample-to-sample variation, whereas the amount of variance attributable to sample handling was small (0.8–17.5%). Residual error (3.2–59.4%), corresponding to un-modelled factors, contributed a greater extent to the total variation than the sample handling procedures.

Conclusion

The application of a specific DNA quantification method to a particular molecular genetic laboratory protocol must take into account the accuracy and precision of the specific method, as well as the requirements of the experimental workflow with respect to sample volumes and throughput. While OD was the most concordant and precise DNA quantification method in this study, the information provided by the quantitative PCR assay regarding the suitability of DNA samples for PCR may be an essential factor for some protocols, despite the decreased concordance and precision of this method.
  相似文献   

12.
A sensitive chronocoulometric aptasensor for the detection of thrombin has been developed based on gold nanoparticle amplification. The functional gold nanoparticles, loaded with link DNA (LDNA) and report DNA (RDNA), were immobilized on an electrode by thrombin aptamers performing as a recognition element and capture probe. LDNA was complementary to the thrombin aptamers and RDNA was noncomplementary, but could combine with [Ru(NH3)6]3+ (RuHex) cations. Electrochemical signals obtained by RuHex that bound quantitatively to the negatively charged phosphate backbone of DNA via electrostatic interactions were measured by chronocoulometry. In the presence of thrombin, the combination of thrombin and thrombin aptamers and the release of the functional gold nanoparticles could induce a significant decrease in chronocoulometric signal. The incorporation of gold nanoparticles in the chronocoulometric aptasensor significantly enhanced the sensitivity. The performance of the aptasensor was further increased by the optimization of the surface density of aptamers. Under optimum conditions, the chronocoulometric aptasensor exhibited a wide linear response range of 0.1–18.5 nM with a detection limit of 30 pM. The results demonstrated that this nanoparticle-based amplification strategy offers a simple and effective approach to detect thrombin.  相似文献   

13.
We selected DNA aptamers against insulin and developed an aptameric enzyme subunit (AES) for insulin sensing. The insulin-binding aptamers were identified from a single-strand DNA library which was expected to form various kinds of G-quartet structures. In vitro selection was carried out by means of aptamer blotting, which visualizes the oligonucleotides binding to the target protein at each round. After the 6th round of selection, insulin-binding aptamers were identified. These identified insulin-binding aptamers had a higher binding ability than the insulin-linked polymorphic region (ILPR) oligonucleotide, which can be called a "natural" insulin-binding DNA aptamer. The circular-dichroism (CD) spectrum measurement of the identified insulin-binding DNA aptamers indicated that the aptamers would fold into a G-quartet structure. We also developed an AES by connecting the best identified insulin-binding aptamer with the thrombin-inhibiting aptamer. Using this AES, we were able to detect insulin by measuring the thrombin enzymatic activity without bound/free separation.  相似文献   

14.
A simple and sensitive electrochemical DNA biosensor based on in situ DNA amplification with nanosilver as label and horseradish peroxide (HRP) as enhancer has been designed. The thiolated oligomer single-stranded DNA (ssDNA) was initially directly immobilized on a gold electrode, and quartz crystal microbalance (QCM) gave the specific amount of ssDNA adsorption of 6.3 ± 0.1 ng/cm2. With a competitive format, hybridization reaction was carried out via immersing the DNA biosensor into a stirred hybridization solution containing different concentrations of the complementary ssDNA and constant concentration of nanosilver-labeled ssDNA, and then further binding with HRP. The adsorbed HRP amount on the probe surface decreased with the increment of the target ssDNA in the sample. The hybridization events were monitored by using differential pulse voltammetry (DPV) with the adsorbed HRP toward the reduction of H2O2. The reduction current from the enzyme-generated product was related to the number of target ssDNA molecules in the sample. A detection of 15 pmol/L for target ssDNA was obtained with the electrochemical DNA biosensor. Additionally, the developed approach can effectively discriminate complementary from non-complementary DNA sequence, suggesting that the similar enzyme-labeled DNA assay method hold great promises for sensitive electrochemical biosensor applications.  相似文献   

15.
Photo-thermal displacement measurement by laser interferometry involves the measurement of temperature change caused by illumination of the sample. To develop a system of detecting unlabeled homogeneous proteins based on laser interferometric measurement of photo-thermal displacement, we studied the interaction between aptamers and their target molecules by using thrombin and the thrombin aptamer as a model target and ligand, respectively. Because of the energy consumed by aptamer-thrombin interactions, the signals obtained from solutions containing aptamer-thrombin mixtures varied depending on the thrombin concentration. We propose that this method involving the use of aptamers and photo-thermal displacement measurement will provide a biomolecular detection system for rapid diagnosis.  相似文献   

16.
Wang Y  He X  Wang K  Ni X  Su J  Chen Z 《Biosensors & bioelectronics》2011,26(8):3536-3541
A sensitive and specific electrochemical assay for detection of thrombin based on aptamer and ferrocenylhexanethiol loaded silica nanocapsules (FcSH/SiNCs) amplification is described. In the protocol, a double aptamer sandwich structure was formed in the presence of thrombin, in which an aptamer-labeled FcSH/SiNCs for electrochemical detection, and a streptavidin-coated magnetic bead immobilized aptamer for rapid and specific separation of target protein. After separated from the sample mixture under a magnetic field, the sandwich complex was treated with NaOH to release the loaded ferrocenylhexanethiol (FcSH) from the silica nanocapsules (SiNCs). Differential pulse voltammetry (DPV) was employed to detect the released FcSH, which was related to the concentration of the thrombin. The method took advantage of sandwich binding of two affinity aptamers for increased specificity, high payload of FcSH in SiNCs for signal amplification, magnetic beads for fast magnetic separation. The peak current of released FcSH had a good linear relationship with the thrombin concentration in the range of 0.1-5 nmol/L, and the detection limit of thrombin in the method was 0.06 nmol/L. The detection was also specific for thrombin without being affected by other proteins, such as immunoglobulin G, bovine serum albumin, lysozyme and human serum albumin. The method has been used to detect thrombin in human serum albumin with minimum background interference.  相似文献   

17.
Aptamers interacting selectively with the anion-binding exosites 1 and 2 of thrombin were merged into dimeric oligonucleotide constructs by means of a poly-(dT)-linker of 35 nucleotides (nt) in length. Complexes of thrombin with the aptamers and their hetero- and homodimeric constructs were measured using an optical biosensor Biacore-3000. The K D values obtained for the hetero- and homodimeric constructs were correspondingly 25–30- and 2–3-fold lower than those for the primary aptamers. Analysis of temperature dependencies of the K D values within the temperature interval of 10–40°C has shown that affinity increases with the temperature decrease. The values of the enthalpy change ΔH upon formation of complexes of thrombin with the aptamers and the heterodimeric construct were basically the same. The value of the entropy change ΔS upon complex formation of thrombin with the aptamer heterodimeric construct was 1.5–2-fold higher than the ΔS values for the complexes with the aptamers. The complex formation and dissociation rates increased with the elevation of temperature from 10 to 37°C. However, at both temperatures the dissociation rate for the complex of thrombin with the heterodimeric construct was evidently lower that for the complexes with the aptamers.  相似文献   

18.
Niu S  Qu L  Zhang Q  Lin J 《Analytical biochemistry》2012,421(2):362-367
A sensitive and specific sandwich assay for the detection of thrombin is described. Two affiliative aptamers were used to increase the assay specificity through sandwich recognition. Recognition DNA loaded on gold nanoparticles (AuNPs) partially hybridized with the initiator DNA, which was displaced by surviving DNA. After the initiator DNA was released into the solution, one hairpin structure was opened, which in turn opened another hairpin structure. The initiator DNA was displaced and released into the solution again by another hairpin structure because of the hybridized reaction. Then the released initiator DNA initiated another autocatalytic strand displacement reaction. A sophisticated network of three such duplex formation cycles was designed to amplify the fluorescence signal. Other proteins, such as bovine serum albumin and lysozyme, did not interfere with the detection of thrombin. This approach enables rapid and specific thrombin detection with reduced costs and minimized material consumption compared with traditional assay processes. The detection limit of thrombin was as low as 4.3 × 10?13 M based on the AuNP amplification and the autocatalytic strand displacement cycle reaction. This method could be used in biological samples with excellent selectivity.  相似文献   

19.
We report novel method of detection thrombin-aptamer interaction based on measurement the charge consumption from the electrode covered by DNA aptamers to an electrochemical indicator methylene blue (MB), that is bounded to a thrombin. The binding of thrombin to an aptamers has been detected also by QCM method in flow measuring cell. We showed that using MB it is possible to detect thrombin with high sensitivity and selectivity.  相似文献   

20.

Background

The interrogation of proteomes (“proteomics”) in a highly multiplexed and efficient manner remains a coveted and challenging goal in biology and medicine.

Methodology/Principal Findings

We present a new aptamer-based proteomic technology for biomarker discovery capable of simultaneously measuring thousands of proteins from small sample volumes (15 µL of serum or plasma). Our current assay measures 813 proteins with low limits of detection (1 pM median), 7 logs of overall dynamic range (∼100 fM–1 µM), and 5% median coefficient of variation. This technology is enabled by a new generation of aptamers that contain chemically modified nucleotides, which greatly expand the physicochemical diversity of the large randomized nucleic acid libraries from which the aptamers are selected. Proteins in complex matrices such as plasma are measured with a process that transforms a signature of protein concentrations into a corresponding signature of DNA aptamer concentrations, which is quantified on a DNA microarray. Our assay takes advantage of the dual nature of aptamers as both folded protein-binding entities with defined shapes and unique nucleotide sequences recognizable by specific hybridization probes. To demonstrate the utility of our proteomics biomarker discovery technology, we applied it to a clinical study of chronic kidney disease (CKD). We identified two well known CKD biomarkers as well as an additional 58 potential CKD biomarkers. These results demonstrate the potential utility of our technology to rapidly discover unique protein signatures characteristic of various disease states.

Conclusions/Significance

We describe a versatile and powerful tool that allows large-scale comparison of proteome profiles among discrete populations. This unbiased and highly multiplexed search engine will enable the discovery of novel biomarkers in a manner that is unencumbered by our incomplete knowledge of biology, thereby helping to advance the next generation of evidence-based medicine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号