首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 32 毫秒
1.
A dual channel surface acoustic wave (SAW) device has been used as a biosensor to detect two different microorganisms, Legionella and Escherichia coli, simultaneously. A series of experiments was conducted to optimise the use of the SAW for bacterial detection using a novel protocol of coating bacteria on the sensor surface prior to addition of the antibody. Results were compared with an experiment in which a conventional protocol was utilised, where antibody was coated on the sensor surface prior to exposure to bacteria. The concentration of bacteria that attached to the surface of the SAW device was related to the antibody that specifically bound to it and therefore to frequency in a dose dependent fashion. Unlike conventional microbiological techniques quantitative results can be obtained for Legionella and E. coli down to 10(6) cells per ml within 3 h. In addition E. coli was detected down to 10(5) cells per ml in a modified protocol using sheep IgG as a blocking agent.  相似文献   

2.
To develop effective protein immobilization technology with minimal amounts of protein for high sensitivity surface acoustic wave biosensors, we determined the binding properties, and morphological characteristics of human interleukin-6 (IL-6), a pro-inflammatory cytokine, on the surface of ZnO, and SiO(2) films grown onto (100) Si substrates, for the first time. Interleukin-6 was immobilized in the range of 0.276-10 pg/ml on the surface of ZnO and SiO(2), and visualized at each stage, while protein-protein interactions were measured with the antigen/antibody immunoassay of solid-phase ELISA, which we modified for these types of substrates. A relative mass value was determined in each case. ELISA detected upward of 1 and 6 ng/ml of protein applied on ZnO and SiO(2), respectively. It is concluded that the more reactive ZnO surface is a new and more effective template for protein immobilization.  相似文献   

3.
Viruses are of high medical and biodefense concern and their detection at concentrations well below the threshold necessary to cause health hazards continues to be a challenge with respect to sensitivity, specificity, and selectivity. Ideally, assays for accurate and real time detection of viral agents would not necessitate any pre-processing of the analyte, which would make them applicable for example to bodily fluids (blood, sputum) and man-made as well as naturally occurring bodies of water (pools, rivers). We describe herein a robust biosensor that combines the sensitivity of surface acoustic waves (SAW) generated at a frequency of 325MHz with the specificity provided by antibodies for the detection of viral agents. A lithium tantalate-based SAW transducer with silicon dioxide waveguide sensor platform featuring three test and one reference delay lines was used to adsorb antibodies directed against either Coxsackie virus B4 or the category A bioagent Sin Nombre virus (SNV), a member of the genus Hantavirus, family Bunyaviridae, negative-stranded RNA viruses. Rapid detection (within seconds) of increasing concentrations of viral particles was linear over a range of order of magnitude for both viruses, although the sensor was approximately 5 x 10(5)-fold more sensitive for the detection of SNV. For both pathogens, the sensor's selectivity for its target was not compromised by the presence of confounding Herpes Simplex virus type 1. The biosensor was able to detect SNV at doses lower than the load of virus typically found in a human patient suffering from hantavirus cardiopulmonary syndrome (HCPS). Further, in a proof-of-principle real world application, the SAW biosensor was capable to selectively detect SNV agents in complex solutions, such as naturally occurring bodies of water (river, sewage effluent) without analyte pre-processing. This is the first study that reports on the detection of viral agents using an antibody-based SAW biosensor that has the potential to be used as a hand-held and self-contained device for rapid viral detection in the field.  相似文献   

4.
A direct piezoelectric flow injection analysis immunoassay for the detection of African Swine Fever virus and antibodies is presented. The peptide-specific monoclonal antibody 18BG3 and the virus protein 73 were used for detection with a quartz crystal microbalance. Accumulation of the analyte on the surface of this mass-sensitive biosensor resulted in a shift of the resonant frequency. Highly selective receptor layers were applied on the sensing electrode of the quartz crystal for detection of the complementary analyte. Different immobilization methods proved to be appropriate for coating of the monoclonal antibody 18BG3. A quartz crystal covalently coated with the antibody 18BG3 detected virus protein VP73 samples more than 20 times and was stable for more than 30 days. The coating of virus protein was performed by physisorption. A sensor with a virus protein receptor layer detected antibody 18BG3 samples 10 times within one day. The sensor device was able to perform one measurement cycle including blocking and regeneration within 30 min. With the help of a suitable carrier liquid, measurements with serum samples were performed. The calibration curves for measurements in buffer and in serum could be determined and the detection limits for virus protein detection were 0.31 and 1 μg/ml, and for antibody detection 0.1 and 0.2 μg/ml, respectively.  相似文献   

5.
Interleukin-6 (IL-6) plays a central role in the pathogenesis of several autoimmune and inflammatory diseases as well as B-cell lymphoproliferative disorders. This work describes the effects of the recombinant or adenovirally-delivered IL-6 superantagonist Sant7, anti-IL-6 and IL-6 receptor monoclonal antibodies in a severe murine model of human B-cell lymphoma induced in SCID mice by transplantation of an LCL-41 cell line variant (isotype-switched IgM>IgG). Survival of 60% of the animals treated with anti-gp130 was observed up to day 33, while about 20% of the animals survived with anti-gp80 and Sant7 treatment. No survival was observed with the anti-IL-6 monoclonal antibody treatment. No significant change in serum and peritoneal levels of human IL-6 (hIL-6) and soluble human IL-6 receptor (shIL-6R) was observed in the recombinant Sant7-treated group towards the control group. The anti-gp80 monoclonal antibody induced significant increase of both hIL-6R and hIL-6 in serum and peritoneum. The anti-gp130 monoclonal antibody treatment determined a reduction of the seric shIL-6R and a significant increase of the seric hIL-6. Anti-IL-6 monoclonal antibody administration resulted in a reduction of serum and in an increase of peritoneal hIL-6. Treatment with adenoviral Sant7 was associated with a reduction of circulating shIL-6R, hIgG and mSAP. However, only marginal anti-tumor efficacy of the adenoviral Sant7 was observed. Overall, the present data suggest a potential for anti-hIL-6 therapy in B-cell lymphomas. Less severe animal models might be useful to better evaluate Sant7 efficacy alone or in combination with other anti-IL-6 therapeutics.  相似文献   

6.
Surface plasmon resonance (SPR) biosensor formats using gold nanoparticle or protein signal amplification for the sensitive assay of small molecules were developed using progesterone as a model compound. Progesterone was immobilized to a dextran surface in the Biacore biosensor through in situ covalent immobilization using an oligoethylene glycol linker attached to the 4 position of the steroid. This surface produced stable antibody binding for in excess of 1100 assay cycles. Using this surface, assays were developed for progesterone using 10- and 20-nm gold-streptavidin labels attached to biotinylated monoclonal antibody in both label prebinding and sequential binding formats. Prelabeling formats gave no signal enhancement but produced assays with limits of detection of 143 pg/ml, compared with approximately 1 ng/ml in previous studies. Sequential binding formats gave signal enhancements of 2.2-fold over the monoclonal antibody and a limit of detection of 23.1 pg/ml. It was found that secondary antibody labeling gave 8.1-fold signal enhancements and a limit of detection of 20.1 pg/ml, whereas use of secondary antibody-25 nm gold complexes provided more signal enhancement (13-fold) and a further improvement in limit of detection of 8.6 pg/ml.  相似文献   

7.
The toxigenic Escherichia coli O157:H7 bacterium has been connected with hemorrhagic colitis and hemolytic uremic syndrome, which may be characterized by diarrhea, kidney failure and death. On average, O157:H7 causes 73,000 illnesses, 2100 hospitalizations and 60 deaths annually in the United States alone. There is the need for sensors capable of rapidly detecting dangerous microbes in food and water supplies to limit the exposure of human and animal populations. Previous work by the authors used shear horizontal surface acoustic wave (SH SAW) devices fabricated on langasite (LGS) Euler angles (0°, 22°, 90°) to successfully detect macromolecular protein assemblies. The devices also demonstrated favorable temperature stability, biocompatibility and low attenuation in liquid environments, suggesting their applicability to bacterial detection. In this paper, a biosensor test setup utilizing a small volume fluid injection system, stable temperature control and high frequency phase measurement was applied to validate LGS SH SAW biosensors for bacterial detection. The LGS SH SAW delay lines were fabricated and derivatized with a rabbit polyclonal IgG antibody, which selectively binds to E. coli O157:H7, in this case a non-toxigenic test strain. To quantify the effect of non-specific binding (negative control), an antibody directed against the trinitrophenyl hapten (TNP) was used as a binding layer. Test E. coli bacteria were cultured, fixed with formaldehyde, stained with cell-permeant nucleic acid stain, suspended in phosphate buffered saline and applied to the antibody-coated sensing surfaces. The biosensor transmission coefficient phase was monitored using a network analyzer. Phase responses of about 14° were measured for the E. coli detection, as compared to 2° due to non-specific anti-TNP binding. A 30:1 preference for E. coli binding to the anti-O157:H7 layer when compared to the anti-TNP layer was observed with fluorescence microscopy, thus confirming the selectivity of the antibody surface to E. coli.  相似文献   

8.
This paper describes the direct label-free detection of antibodies against the Epstein-Barr virus (anti-EBNA) using a surface plasmon resonance (SPR) biosensor. The antibody detection was performed using the immunoreaction between anti-EBNA and a respective synthetic peptide (EBNA-1), which was conjugated with bovine serum albumin (BSA-EBNA) and immobilized on the sensor surface. Three immobilization chemistries for the attachment of BSA-EBNA were investigated to optimize ligand density and minimize loss of EBNA-1 immunoreactivity. The developed SPR biosensor functionalized with the optimal immobilization method was calibrated and characterized in terms of detection limit, reproducibility, regenerability and storability. It was demonstrated that the sensor is capable of detecting concentrations of anti-EBNA as low as 0.2 ng/ml (approximately 1 pM) both in buffer and 1% human serum and can be stored and regenerated for repeated use.  相似文献   

9.
The biochemical nature of endogenous interleukin-6 (IL-6) as it exists in human serum or plasma was investigated. Serum from a patient following bone marrow (BM) transplantation and fresh plasma samples from patients with epidermolysis bullosa or psoriasis, as well as from normal volunteers, were fractionated through G-200 columns and each of the eluted fractions assayed for IL (interleukin)-6 content using enzyme-linked immunosorbent assays (ELISAs) based on the monoclonal antibody (mAb) pairs IG61/5IL6 or 4IL6/5IL6 and in the B9 hybridoma growth factor bioassay. The IG61/5IL6 ELISA and the B9 assay detected IL-6 in BM serum almost exclusively of molecular mass approximately 20 kDa. In contrast, the 4IL6/5IL6 ELISA detected strong IL-6 immunoreactivity in complexes of size 100-150 and 400-500 kDa. IL-6 present in the 100-150- and 400-500-kDa complexes was purified by immunoaffinity chromatography through a 5IL6 mAb column. The 5IL6 mAb immunoaffinity column eluate of the respective pools from BM serum contained IL-6 at concentrations approaching 1 microgram/ml as characterized by Western blotting. Sufficient IL-6 and associated proteins were purified by 5IL6 mAb immunoaffinity column chromatography of the 100-150-kDa complex from 0.8 ml of BM serum to allow (i) verification of three of the polypeptides as IL-6 by amino-terminal sequencing (estimate of IL-6 in original serum sample: 5-10 micrograms/ml), (ii) identification by amino acid sequencing of the "associated" proteins as complement factor C3b (carboxyl-terminal of the alpha-chain), complement factor C4b (gamma-chain), C-reactive protein, and albumin, and (iii) detection of an "associated" polypeptide consistent with the soluble IL-6 receptor. Taken together, these data establish that IL-6 is present at unexpectedly high concentrations in human blood in novel biochemical complexes that include other plasma proteins, which in turn, can camouflage IL-6 immunoreactivity and bioactivity as measured in conventional assays.  相似文献   

10.
The immobilization efficiency of molecular detectors is of great importance with regard to the performances of biosensors such as the sensitivity, stability, and reproducibility. This paper presents a biomimetic olfactory receptor-based biosensor with better performances by improving the immobilization efficiency of molecular detectors for odorant sensing. A mixed self-assembled monolayers (SAMs) functionalized with specific olfactory receptors (ODR-10) was constructed on the sensitive area of surface acoustic wave (SAW) chip. The immobilization of ODR-10 was characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The responses of this biosensor to various odorants were recorded by monitoring the resonance frequency shifts of SAW, which is correlated to the mass loading on its sensitive area. All the results demonstrate this biosensor can specifically respond to the natural ligand of ODR-10, diacetyl, with high sensitivity and stability. The sensitivity is 4 kHz/ng, which is 2× higher than that of previous work. The detection limit is 1.2×10(-11) mM. The major advances on immobilization efficiency of molecular detectors presented in this work could substantially promote and accelerate the researches and applications of olfactory receptor-based biosensors with different transducers, such as quartz crystal microbalance (QCM), surface plasma resonance (SPR), and field effect transistors (FET).  相似文献   

11.
Since the anthrax spore bioterrorism attacks in America in 2001, the early detection of Bacillus anthracis spores and vegetative cells has gained significant interest. At present, many polyclonal antibody-based quartz crystal microbalance (QCM) sensors have been developed to detect B. anthracis simulates. To achieve a simultaneous rapid detection of B. anthracis spores and vegetative cells, this paper presents a biosensor that utilizes an anti-B. anthracis monoclonal antibody designated to 8G3 (mAb 8G3, IgG) functionalized QCM sensor. Having compared four kinds of antibody immobilizations on Au surface, an optimized mAb 8G3 was immobilized onto the Au electrode with protein A on a mixed self-assembled monolayer (SAM) of 11-mercaptoundecanoic acid (11-MUA) and 6-mercaptohexan-1-ol (6-MHO) as adhesive layer. The detection of B. anthracis was investigated under three conditions: dip-and-dry, static addition and flow through procedure. The results indicated that the sensor yielded a distinct response to B. anthracis spores or vegetative cells but had no significant response to Bacillus thuringiensis species. The functionalized sensor recognized B. anthracis spores and vegetative cells specifically from its homophylic ones, and the limit of detection (LOD) reached 10(3)CFU or spores/ml of B. anthracis in less than 30 min. Cyclic voltammogram (CV) and scanning electronic microscopy (SEM) were performed to characterize the surface of the sensor in variable steps during the modification and after the detection. The mAb functionalized QCM biosensor will be helpful in the fabrication of a similar biosensor that may be available in anti-bioterrorism in the future.  相似文献   

12.
A label-free optical biosensor based on a nanostructured porous Si is designed for rapid capture and detection of Escherichia coli K12 bacteria, as a model microorganism. The biosensor relies on direct binding of the target bacteria cells onto its surface, while no pretreatment (e.g. by cell lysis) of the studied sample is required. A mesoporous Si thin film is used as the optical transducer element of the biosensor. Under white light illumination, the porous layer displays well-resolved Fabry-Pérot fringe patterns in its reflectivity spectrum. Applying a fast Fourier transform (FFT) to reflectivity data results in a single peak. Changes in the intensity of the FFT peak are monitored. Thus, target bacteria capture onto the biosensor surface, through antibody-antigen interactions, induces measurable changes in the intensity of the FFT peaks, allowing for a ''real time'' observation of bacteria attachment.The mesoporous Si film, fabricated by an electrochemical anodization process, is conjugated with monoclonal antibodies, specific to the target bacteria. The immobilization, immunoactivity and specificity of the antibodies are confirmed by fluorescent labeling experiments. Once the biosensor is exposed to the target bacteria, the cells are directly captured onto the antibody-modified porous Si surface. These specific capturing events result in intensity changes in the thin-film optical interference spectrum of the biosensor. We demonstrate that these biosensors can detect relatively low bacteria concentrations (detection limit of 104 cells/ml) in less than an hour.  相似文献   

13.
Localization of human mononuclear cell interleukin 1   总被引:12,自引:0,他引:12  
The detection and localization of interleukin (IL) 1 in human monocytes was carried out by flow cytometry using monoclonal antibodies to IL-1 alpha and IL-1 beta proteins. IL-1 alpha was detected on the surface of monocytes and the surface expression increased following lipopolysaccharide activation. No demonstrable IL-1 beta protein could be observed on the cell surface by antibody staining, while both IL-1 alpha and IL-1 beta could be visualized intracellularly by the appropriate monoclonal antibodies following acetone permeabilization of the monocytes. Further experiments with cell associated IL-1 revealed that most of the biological activity of human monocytes could be inhibited by affinity purified polyclonal antibodies to IL-1 alpha protein, whereas no inhibitory activity was observed with IL-1 beta specific antibodies. These data support the hypothesis that a differential localization of IL-1 alpha and IL-1 beta exists within human blood-derived monocytes.  相似文献   

14.
The detection of hepatitis B virus surface antigen (HBsAg) with the use of a model IAsys+ two-channel optical biosensor is based on the registration of interaction between anti-HBs monoclonal antibodies forming the surface layer of the biochip of the biosensor cuvette and blood serum HBsAg. For the first time a two-channel optical biosensor has been used for the detection of HBsAg in blood serum samples. The comparative analysis of the detection of HBsAg by two methods, viz. with the use of an optical biosensor and the enzyme immunoassay, has demonstrated lower sensitivity, but higher specificity of the detection of this antigen by means of a model IAsys+ biosensor with the biochip, prepared in the process of the work. The main advantages of the biosensor detection lie in the registration of interaction in real time without introducing special markers into the molecules under study.  相似文献   

15.
A recombinant mouse interleukin-4 (IL-4) and three different purified rat antimouse IL-4 monoclonal antibodies (Mab) with different clonalities were employed as a model system. This system was used to examine monoclonal antibody effectiveness using both conventional and high-throughput measurement techniques to select antibodies for attaining the most sensitive detection of the recombinant IL-4 through the "sandwich-type" immunoassays. Surface plasmon resonance (SPR) measurements and two high-throughput methods, suspension arrays (also called multiplexed bead arrays) and forward-phase protein microarrays, predicted the same capture (BVD4-1D11) and detection (BVD6-24G2) antibody pair for the most sensitive detection of the recombinant cytokine. By using this antibody pair, we were able to detect as low as 2 pg/mL of IL-4 in buffer solution and 13.5 pg/mL of IL-4 spiked in 100% normal mouse serum with the multiplexed bead arrays. Due to the large amount of material required for SPR measurements, the study suggests that the multiplexed bead arrays and protein microarrays are both suited for the selection of numerous antibodies against the same analyte of interest to meet the need in the areas of systems biology and reproducible clinical diagnostics for better patient care.  相似文献   

16.
A biosensor for the serum cytokine, interleukin-12 (IL-12), based upon a label-free electrochemical impedance spectroscopy monitoring is described. Overexpression of IL-12 has been correlated to the diagnosis of multiple sclerosis (MS). The prototype biosensor was fabricated on a disposable gold-coated silver ribbon electrode by immobilizing anti-IL-12 monoclonal antibodies (mAbs) onto the surface of the electrode. This technique was advantageous as the silver electrodes provided a more rigid and conductive substrate than thin gold foil electrodes and helped in obtaining more reproducible data when used with the electrode holder. Results indicate that IL-12 can be detected at physiological levels, <100 fM with p<0.05 in a label-free and real-time manner. The cost-effective approach described here can be used for diagnosis of diseases (like MS) with known biomarkers in body fluids and for monitoring physiological levels of biomolecules with healthcare, food, and environmental relevance.  相似文献   

17.
Olfactory receptors, which are responsible for sensing odor molecules, form the largest G protein-coupled receptor (GPCR) family in mammalian animals. These proteins play an important role in the detection of chemical signals and signal transduction to the brain. Currently, only a limited number of olfactory receptors have been characterized, which is mainly due to the lack of sensitive and efficient tools for performing functional assays of these receptors. This paper describes a novel surface acoustic wave (SAW)-based biosensor for highly sensitive functional assays of olfactory receptors. An olfactory receptor of Caenorhabditis elegans, ODR-10, was expressed on the plasma membrane of human breast cancer MCF-7 cells, which was used as a model system for this study. For specific odorant response assays, the membrane fraction of MCF-7 cells containing ODR-10 was extracted and integrated with our SAW sensors. The response of ODR-10 to various odorants was monitored by recording the resonance frequency shifts of SAWs applied to the sensor. Our results show that heterologously expressed ODR-10 receptors can specifically respond to diacetyl, its natural ligand. Dose-dependent responses were obtained by performing measurements using various concentrations of diacetyl. The sensitivity of this biosensor is 2 kHz/ng and can detect concentrations as low as 10−10 mM, which is 10× lower than what has previously been reported. This biosensor can be used to characterize odorant response profiles of olfactory receptors and provide information rich data for functional assays of olfactory receptors. In addition to providing a greater understanding of the biological mechanisms of GPCRs, such data holds great potential in many other fields such as food industry, biomedicine, and environmental protection.  相似文献   

18.
Nanoparticle labels conjugated with biomolecules are used in a variety of different assay applications. In this paper, a sensitive fluoroimmunoassay for recombinant human interleukin-6 (IL-6) with the functionalized Rubpy-encapsulated fluorescent core-shell silica nanoparticles labeling technique has been proposed. IL-6 was measured based on the specific interaction between captured IL-6 antigen and functionalized fluorescent core-shell nanoparticles-labeled anti-IL-6 monoclonal antibody. The calibration graph for IL-6 was linear over the range 20-1250 pg ml(-1) with a detection limit of 7 pg ml(-1) (3 sigma). The regression equation of the working curve is I(F)=7.665+32.499[IL-6] (ng ml(-1)) (r=0.9980). The relative standard deviation (R.S.D.) for 11 parallel measurements of 78 pg ml(-1) IL-6 was 3.2%. Furthermore, the application of fluorescence microscopy imaging in the study of the antibody labeling and sandwich fluoroimmunoassay with the functionalized fluorescent core-shell silica nanoparticles was also explored. This proposed method has the advantage of showing the specificity of immunoassay and sensitivity of fluorescent nanoparticle labels technology. The results demonstrate that the method offers potential advantages of sensitivity, simplicity and reproducibility for the determination of IL-6, and is applicable to the determination of IL-6 in serum samples and enabling fluorescence microscopy imaging for the determination of IL-6.  相似文献   

19.

Background

Cytomegalovirus (CMV) is the most common infectious cause of mental disability in newborns in developed countries. There is an urgent need to establish an early detection and high-throughput screening method for CMV infection using portable detection devices.

Methods

An antibody analysis method is reported for the detection and identification of CMV antibodies in serum using a biosensor based on high spatial resolution imaging ellipsometry (BIE). CMV antigen (CMV-3A) was immobilized on silicon wafers and used to capture CMV antibodies in serum. An antibody against human immunoglobulin G (anti-IgG) was used to confirm the IgG antibody against CMV captured by the CMV-3A.

Results

Our results show that this assay is rapid and specific for the identification of IgG antibody against CMV. Further, patient serum was quantitatively assessed using the standard curve method, and the quantitative results were in agreement with the enzyme-linked immunosorbent assay. The CMV antibody detection sensitivity of BIE reached 0.01 IU/mL.

Conclusions

This novel biosensor may be a valuable diagnostic tool for analysis of IgG antibody against CMV during CMV infection screening.  相似文献   

20.
In this study, a specific monoclonal antibody againstListeria monocytogenes was screened using an SPR biosensor Monoclonal antibodies were bound to protein L, after which theL. monocytogenes cells were subjected to an affinity assay. Protein L was immobilized on a carboxymethyl dextran (CM-Dex) surface via an amine coupling method and utilized repeatedly by regeneration. The monoclonal antibody, ‘A18’, was selected and employed for the high-sensitivity detection ofL. monocytogenes. Under optimized conditions, 103 cells/ml or 50 cells were detected by the SPR biosensor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号