首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
C Xu  J Auger 《Cytometry》1990,11(3):349-358
Flow cytometry data of spinach thylakoid membrane preparations indicate the presence of a homogeneous thylakoid population. Fluorescence data from a flow cytometer and comparison with data from two other fluorometers show that chlorophyll a fluorescence detected with a flow cytometer has the character of maximum fluorescence (Fmax), not of the constant component (Fo). This conclusion is important since Fo measures fluorescence that is affected mostly by changes in excitation energy transfer and Fmax-Fo (the variable fluorescence) by changes in photochemistry. This was demonstrated by: 1) The light intensity as well as diffusion rate dependence of the quenching effect of various quinones (p-benzoquinone, phenyl-benzoquinone, and 2,5-dibromo-3-methyl-6-isopropyl-p-benzoquinone, DBMIB) on fluorescence yield; quenching for the same concentration of these quinones was lower at the higher than at the lower light intensities. 2) Temperature dependence of the fluorescence yield; increasing the temperature from 20 to 70 degrees C did not show an increase in fluorescence yield using a flow cytometer in contrast to measurements with weak excitation light, but similar to those obtained for Fmax. 3) Addition of an inhibitor diuron up to 100 microM did not change the fluorescence intensity. A comparison of quenching of fluorescence by various quinones obtained by flow cytometry with those by other fluorometers suggests that the high intensity used in the cytometry produces unique results: the rate of reduction of quinones in much larger than the rate of equilibration with the bulk quinones.  相似文献   

2.
J Dorsey  C M Yentsch  S Mayo  C McKenna 《Cytometry》1989,10(5):622-628
A standard method for the assessment of cell viability has been developed for marine phytoplankton using an inexpensive stain, fluorescein diacetate (FDA), at .75 microM for 10 min. A flow cytometer was used as the fluorescence detector, providing an assessment of viability for each individual particle. Cell size and chlorophyll fluorescence per cell were assessed simultaneously, permitting an assignment of viability to specific subpopulations, thus increasing the power of the technique. A reasonable correspondence between FDA mean fluorescence intensity per cell and an independent metabolic indicator, photosynthetic capacity measured by 14C, was found. Both FDA mean fluorescence intensity and photosynthetic capacity vary as a function of cell volume. Recovery after extended periods of darkness indicate that cells that are FDA negative may not be dead, but merely quiescent or inactive.  相似文献   

3.
Traditionally, many cell-based assays that analyze cell populations and functionalities have been performed using flow cytometry. However, flow cytometers remain relatively expensive and require highly trained operators for routine maintenance and data analysis. Recently, an image cytometry system has been developed by Nexcelom Bioscience (Lawrence, MA, USA) for automated cell concentration and viability measurement using bright-field and fluorescent imaging methods. Image cytometry is analogous to flow cytometry in that gating operations can be performed on the cell population based on size and fluorescent intensity. In addition, the image cytometer is capable of capturing bright-field and fluorescent images, allowing for the measurement of cellular size and fluorescence intensity data. In this study, we labeled a population of cells with an enzymatic vitality stain (calcein-AM) and a cell viability dye (propidium iodide) and compared the data generated by flow and image cytometry. We report that measuring vitality and viability using the image cytometer is as effective as flow cytometric assays and allows for visual confirmation of the sample to exclude cellular debris. Image cytometry offers a direct method for performing fluorescent cell-based assays but also may be used as a complementary tool to flow cytometers for aiding the analysis of more complex samples.  相似文献   

4.
We describe a simple and rapid method for determining the linearity of a flow cytometer amplification system. The method is based on a fundamental characteristic of linear amplifiers: The difference between two amplified signals increases linearly with increasing amplifier gain. Two populations of beads or cells, differing slightly in fluorescence intensity, are analyzed by the flow cytometer at increasing photomultiplier tube high-voltage settings. The distribution of the populations' mean difference versus mean position is a straight line intersecting the origin for linear amplifiers. Although some types of nonlinearities cannot be detected with this technique, deviations from linearity indicate nonlinear components in the flow cytometer amplification system. The correlation coefficient is used to quantify degree of nonlinearity. We also describe a method for amplifier nonlinearity compensation.  相似文献   

5.
V Kachel  O Kempski  J Peters  F Sch?del 《Cytometry》1990,11(8):913-915
Recently, new fluorescent dyes have been introduced into flow cytometry which alter their spectral characteristics when changes occur in certain cell features, e.g., intracellular pH or calcium ion concentration. Such changes may be determined by measuring the fluorescence intensity ratio in two different wavelength ranges (5). Here a new method is described, which simplifies the use of steadily flowing fluids for calibration. The pulse electronics of a flow cytometer cannot process the static fluorescence signals of a streaming fluid. If, however, the exciting or emitted fluorescence light of a calibration fluid is made pulsating, the flow cytometer electronics can evaluate those pulses. The new calibration procedure uses measurement of two wavelength windows shown in a two-parameter display to generate an absolute calibration scale. Measurement of the spectral shift in calibration fluids under identical instrumental settings provides absolute values that measurements of intracellular concentrations can be referred to.  相似文献   

6.
BACKGROUND: The application of molecules that fluoresce in the infrared (IR) region to measure cell products would be enhanced by a flow cytometer capable of measuring them. To our knowledge, none exist at this time. Accordingly, we have developed such an instrument. METHODS: A Becton Dickinson LSR flow cytometer was modified to include a small 785-nm IR diode laser the size of a C cell battery with 44-mW output power. The instrument was modified further to accommodate this laser in addition to a 405-nm solid-state laser, a 488-nm air-cooled argon laser, and a 658-nm solid-state laser. Because the IR laser is dangerous to the eye, the laser beams were viewed for optical alignment using a CCD camera and video monitor. An avalanche photodiode was used in place of a photomultiplier tube because its detection sensitivity in the IR region is superior. RESULTS: To assess performance, scatter and fluorescence measurements were made using microspheres that fluoresce in the IR region, and human leukocytes were stained with CD45 biotin followed by a streptavidin conjugated with an IR dye. An avalanche photodiode was 2.3 to 2.8 times more sensitive than a photomultiplier tube for detecting IR fluorescence. Cells stained with CD45 biotin and avidin conjugated with an IR dye could easily be resolved and their fluorescence quantified; there was virtually no autofluorescence. In addition, a lipophilic membrane dye that emits in the IR region was studied. HL60 cells were stained with this dye and they exhibited bright fluorescence intensity. CONCLUSION: A commercial instrument could be modified to accommodate an IR laser for exciting dyes that fluoresce in the IR region. This new capability will extend the range of fluorescence that can be measured by flow cytometry.  相似文献   

7.
We have previously demonstrated age-related differences in human lymphocyte membrane fluidity, by use of steady-state polarization measurements on bulk cell suspensions with the fluorescence probe DPH. However, for exact analysis of the possible functional importance of these changes, single-cell measurements were deemed of interest. We have now used an analog division device to measure fluorescence depolarization "p" of DPH in real time with a FACS III flow cytometer. The measurements are reliable, as we have been able to confirm the differences in DPH "p" between monocytes and lymphocytes previously shown in bulk suspension and to demonstrate the expected differences in fluidity of lipid-modulated cells. We also found significant differences in DPH "p" between lymphocytes of young and elderly blood donors. Lymphocyte subsets did not differ in polarization values but did differ in fluorescence intensity with Th less than Ts less than B = NK cells.  相似文献   

8.
In the previous article [Part 1 (8)], we have modelled alternative approaches to design of practical time-gated luminescence (TGL) flow cytometry and examined the feasibility of employing a UV LED as the excitation source for the gated detection of europium dye labelled target in rapid flow stream. The continuous flow-section approach is well suited for rare-event cell counting in applications with a large number of nontarget autofluorescent particles. This article presents details of construction, operation and evaluation of a TGL flow cytometer using a UV LED excitation and a gated high-gain channel photomultiplier tube (CPMT) for detection. The compact prototype TGL flow cytometer was constructed and optimised to operate at a TGL cycle rate of 6 kHz, with each cycle consisting of 100 micros LED pulsed excitation and approximately 60 micros delay-gated detection. The performance of the TGL flow cytometer was evaluated by enumerating 5.7 microm Eu(3+) luminescence beads (having comparable intensity to europium-chelate-labeled Giardia cysts) in both autofluorescence-rich environmental water concentrates and Sulforhodamine 101 (S101) solutions (broadband red fluorescence covering the spectral band of target signals), respectively.The prototype TGL flow cytometer was able to distinguish the target beads, and a maximum signal to background ratio of 38:1 was observed. Neither the environmental water concentrates nor S101 solution contributed to the background in the TGL detection phase. The counting efficiency of the TGL flow cytometer was typically >93% of values determined using conventional counting methods.  相似文献   

9.
Saccharomyces cerevisiae strains that respond to environmental changes and transmit the information by emission of fluorescence from the cell surface were constructed. The technique of cell surface engineering enabled the yeast cells to display enhanced cyan blue fluorescent protein (ECFP) or enhanced yellow fluorescent protein (EYFP) on the surface under the control of promoters that sense environmental changes. Two model promoters were examined in this study. For monitoring the intra- and extracellular concentrations of phosphate ion, the PHO5 promoter was chosen to display ECFP. The MEP2 promoter was used to display EYFP to sense the concentrations of ammonium ion. Fluorescence was observed by fluorescence microscopy and immunofluorescence microscopy, and the intensity was measured by a flow cytometer. The relationship between ion concentration inside and outside the cells was evaluated by the change in the rate of fluorescence. This S. cerevisiae system enables environmental changes to be transmitted as intra- and extracellular information using a suitable promoter functioning at real time and in a non-invasive manner.  相似文献   

10.
毕赤酵母是当前应用最为广泛的重组蛋白表达系统之一,文中建立了一种快速筛选高效表达重组蛋白的毕赤酵母菌株的新方法。首先,对内质网转膜蛋白Sec63融合表达增强型绿色荧光蛋白EGFP的改造菌株GS115-E表达重组蛋白的能力进行检测;之后将携带不同拷贝数的植酸酶phy基因或木聚糖酶xyn基因的质粒转化进入GS115-E中,得到具有不同植酸酶或木聚糖酶表达水平的重组菌株,分别检测不同菌株的EGFP与重组蛋白的表达水平;最后,利用分选型流式细胞仪,根据绿色荧光值的高低对包含不同植酸酶表达水平的重组菌株的菌群进行分选。结果显示重组菌株中EGFP的荧光值与重组蛋白的活性表达水平之间具有良好的线性相关性(0.8|R|1),且利用流式细胞仪可高效地从混合菌群中筛选得到高产菌株,所分选得到的高荧光菌株在摇瓶发酵120 h时植酸酶表达水平是低荧光菌株的4.09倍。本方法通过检测菌株的EGFP荧光值代替检测重组蛋白的表达水平和活性,从而实现高表达菌株的筛选,大大提高了其应用的便捷性及通用性。与流式细胞仪、液滴微流控等高通量筛选仪器或技术结合将进一步提高筛选的速度与通量,为筛选获得高效表达重组蛋白的毕赤酵母菌株提供了简便、快速的新途径。  相似文献   

11.
A high throughput method for screening of protein expression is described. By using a flow cytometer, levels of both soluble and precipitated protein can simultaneously be assessed in vivo. Protein fragments were fused to the N-terminus of enhanced GFP and the cell samples were analysed using a flow cytometer. Data concerning whole cell fluorescence and light scattering was collected. The whole cell fluorescence is probing intracellular concentrations of soluble fusion proteins. Concurrently, forward scattered light gives data about inclusion body formation, valuable information in process optimisation. To evaluate the method, the cells were disrupted, separated into soluble and non-soluble fractions and analysed by gel electrophoresis. A clear correlation between fluorescence and soluble target protein was shown. Interestingly, the distribution of the cells regarding forward scatter (standard deviation) correlates with the amount of inclusion bodies formed. Finally, the newly developed method was used to evaluate two different purification tags, His(6) and Z(basic), and their effect on the expression pattern.  相似文献   

12.
A method for the determination of circulating immune complexes (CIC) was adapted for flow cytometric analysis. Human granulocytes were used to phagocytose IgG-bearing CIC of serum from systemic lupus erythematosus (SLE) patients. A method for labeling the phagocytosed CIC with FITC-conjugated anti-human IgG was developed where the granulocytes remain in suspension during fixation and labeling. The fluorescence per cell, measured with a flow cytometer, is a measure of the total amount of the phagocytosed IgG. The results indicate that a rapid and quantitative method for the detection and measurement of phagocytosed CIC is possible using the flow cytometer.  相似文献   

13.
DNA-staining of hamster testis cell suspensions followed by flow cytometry demonstrated appearance of the first haploid cells at 23 days post partum (dpp) and of condensed chromatin (in elongated spermatids and spermatozoa) at 33-34 dpp. Mature spermatozoa were first observed in the caput epididymis at 36-37 dpp, thus completing the first spermatogenic wave. Testicular cell suspensions from animals from 23 to 38 dpp were stained with acridine orange, and flow cytometer gating was adjusted to include only the haploid cells. Acridine orange intercalated into double-stranded DNA to produce green fluorescence. The decrease in green fluorescence intensity from 23 until 37 dpp was caused by changes in the binding of DNA to basic proteins in such a fashion as to impede the access of the dye to the DNA double helix. When the green fluorescence values (of the most advanced spermatids) were plotted against the age of the hamsters (in dpp) or the corresponding steps of spermiogenesis, the decrease in fluorescence could be seen to occur in three phases. The inflection point between the first and second phases was observed at about spermiogenesis step 7, consistent with the hypothesis that this represents removal of histone from the chromatin. The second phase presumably represents the period in which transition proteins are bound to the DNA. At approximately steps 15 or 16 a further inflection point was seen where protamines replaced the transition proteins. The red fluorescence produced when acridine orange bound to RNA in spermatids, increased early in spermiogenesis and decreased dramatically at 34 dpp, consistent with the fact that elongating spermatids discard the bulk of their cytoplasm during the maturation process.  相似文献   

14.
Single-cell and population information are commonly obtained either by flow cytometry or fluorescence microscopy. However, these two methods provide different information. Flow cytometry gives quantitative multi-parametric information about physical characteristics and staining or expression, but doesn''t allow for visualization. Stand-alone fluorescence microscopy provides visual data, but doesn''t allow for straightforward quantitative measurements1.Image-based cytometry bridges the gap between these two methods, enabling the quick visualization and simultaneous quantitative analysis of thousands of cells in heterogeneous populations2. Here, we present a method for performing cell viability and green fluorescent protein (GFP) expression assays using the Tali Image-Based Cytometer3. The Tali instrument is a 3-channel (bright field, green fluorescence, red fluorescence) benchtop assay platform that offers several advantages over flow cytometry and fluorescence microscopy. The Tali cytometer is less expensive, takes up less bench space, requires less maintenance, and the work flow has been simplified so that the operation and analysis is much simpler and quicker. The Tali cytometer is capable of performing a range of suspension cell-based assays, including GFP and red fluorescent protein (RFP) expression, apoptosis4-6 and cell viability analysis with propidium iodide (PI)7-11.Here, we demonstrate the use of the Tali instrument in performing a cell viability assay in cells expressing GFP. GFP-transduced cells are stained using the Tali Viability Kit - Dead Cell Red. The cells are then pipetted into a Tali Cellular Analysis Slide and loaded into the cytometer. Bright field, red fluorescence and green fluorescence images are captured and analyzed using assay specific algorithms. Histograms are then generated to display cell size, PI fluorescence intensity, and GFP fluorescence intensity. These parameters can then be thresholded to home in on a specific cell population.A side-by side comparison of the Tali Image-Based Cytometer and traditional flow cytometry demonstrates that the two methods provide comparable data regarding cell viability and protein expression. However, the Tali instrument provides additional visual information about the cell population that cannot be obtained using a flow cytometer.Download video file.(64M, mov)  相似文献   

15.
Analysis of phytoplankton by flow cytometry   总被引:3,自引:0,他引:3  
Optical properties of eight algae species were measured on a flow cytometer. Forward and perpendicular light scatter measurements provide information on the size and shape of algae cells. The intensity of chlorophyll fluorescence varies greatly among the studied algae species and can be used to distinguish them. Measurements of chlorophyll fluorescence after excitation with different wavelengths provide a fluorescence excitation spectrum for each species over the available wavelength range. These spectra reflect the different photosynthetic pigment contents of the species. Staining algae cells with the DNA stains, Hoechst 33342 and DAPI, provides two additional optical parameters to distinguish algae populations: blue nuclear fluorescence and yellow granular fluorescence. The combination of these optical measurements enables the distinction of each algae species into a small cluster in a hyperspace of parameters. The automation of phytoplankton analysis on the flow cytometer may lead to the rapid and objective assessment of water quality.  相似文献   

16.
J Mullikin  R Norgren  J Lucas  J Gray 《Cytometry》1988,9(2):111-120
We describe the development of a scanning flow cytometer capable of measuring the distribution of fluorescent dye along objects with a spatial resolution of 0.7 micron. The heart of this instrument, called a fringe-scan flow cytometer, is an interference field (i.e., a series of intense planes of illumination) produced by the intersection of two laser beams. Fluorescence profiles (i.e., records showing the intensity of fluorescence measured at 20 ns intervals) are recorded during the passage of objects through the fringe field. The shape of the fringe field is determined by recording light scatter profiles as 0.25 micron diameter microspheres traverse the field. The distribution of the fluorescent dye along each object passing through the fringe field is estimated from the recorded fluorescence profile using Fourier deconvolution. We show that the distribution of fluorescent dye along microsphere doublets and along propidium iodide stained human chromosomes can be determined accurately using fringe-scan flow cytometry. The accuracy of fringe-scan shape analysis was determined by comparing fluorescence profiles estimated from fringe-scan profiles for microspheres and chromosomes with fluorescence profiles for the same objects measured using slit-scan flow cytometry.  相似文献   

17.
A new flow cytometric method is presented that quantifies the frequency of radiation-induced micronuclei in mammalian cell cultures with high precision. After preparing a suspension of main nuclei and micronuclei stained with ethidium bromide and Hoechst 33258, both types of particles are measured simultaneously in a flow cytometer using forward light scatter and three fluorescence emission intensities excited by UV, 488 nm, and by energy transfer from Hoechst 33258 to ethidium bromide. Nonspecific debris overlapping the micronucleus distribution especially in the low fluorescence intensity region was discriminated from micronuclei by calculating ratios of the different fluorescences. The frequencies of radiation-induced micronuclei measured with this new technique agreed well with results obtained by conventional microscopy. The lower limit of the DNA content of micronuclei identified by this technique was found to be about 0.5%-0.75% of the DNA content of G1-phase nuclei. Dose effect curves and the time-dependent induction of micronuclei were measured for two different mouse cell lines.  相似文献   

18.
Helium-neon lasers are economical and efficient light sources; their utility in flow cytometry to date has been limited by the lack of fluorescent probes that can be excited at 633 nm. Allophycocyanin (APC), a highly fluorescent phycobiliprotein, can be used as an antibody label and has spectral characteristics suitable for use with He-Ne lasers; we undertook to resolve whether a low-power (7 mW) He-Ne laser could provide sufficient excitation to permit flow cytometric detection of APC-labeled antibodies on cell surfaces. We made an APC conjugate of monoclonal antibody 4F2, which reacts with an antigen abundant on the surfaces of activated human T-lymphocytes; APC-4F2 was used to stain blood mononuclear cells that had been cultured with and without phytohemagglutinin (PHA). Cells so stained were examined in a flow cytometer with orthogonal illumination at 633 nm from a 7 mW He-Ne laser; antibody-bearing cells were detectable by fluorescence emission above 665 nm. Cells from the same cultures were stained with fluorescein-labeled 4F2 antibody and examined in a flow cytometer with argon ion laser excitation at 488 nm. Percentages of antibody-bearing cells determined from APC fluorescence and from fluorescein fluorescence were in good agreement. It thus appears that He-Ne lasers and APC-antibodies are usable for immunofluorescence measurements; the sensitivity attainable with this technique remains to be determined.  相似文献   

19.
Here, we describe a yeast-based fluorescence reporter assay for G protein-coupled receptor (GPCR) signalling using a flow cytometer (FCM). The enhanced green fluorescent protein (EGFP) gene was integrated into the FUS1 locus as a reporter gene. The engineered yeast was able to express the EGFP in response to ligand stimulation. Gene-disrupted yeast strains were constructed to evaluate the suitability of the yeast-based fluorescence screening system for heterologous GPCR. When receptor was expressed by episomal plasmid, the proportion of the signalling-activated cells in response to ligand stimulation decreased significantly. The GPCR-signalling-activated and non-activated cell clusters were individually isolated by analysing the fluorescence intensity at the single-cell level with FCM, and it was found that the plasmid retention rate decays markedly in the non-activated cell cluster. We attributed the loss of plasmid to G1 arrest in response to signalling, and successfully improved the plasmid retention rate by disrupting the FAR1 gene and avoiding cell cycle arrest. Our system will be a powerful tool for the quantitative and high-throughput GPCR screening of yeast-based combinatorial libraries using FCM.  相似文献   

20.
The CUBIC program displays three-dimensional colored dot plots of flow cytometric trivariate data collected by unmodified commercial instruments (FACScan flow cytometer, FACS 440 cell sorter). Assuming a bimodal distribution of the fluorescence intensity of the cells, the eight theoretical subpopulations involved in a three-color fluorescence histogram are clearly localized in the 3-D space by colored dots that are clustered near each corner of a cubic frame. Rotation, tilting, and zoom functions are available. Table look-up is not needed. CUBIC was illustrated by two experiments: 1) three-color immunofluorescence of antigens on human lymphocytes using monoclonal antibodies conjugated either to fluorescein (FITC), to R-phycoerythrin (PE), or to biotin revealed by a streptavidin coupled to a PE-Texas red tandem conjugate (TC); 2) two-color immunofluorescence of CD4 and CD8 antigens on thymocytes of healthy or preleukemic mice correlated to the DNA content quantified by 7-amino-actinomycin D (7-AAD). The three fluorescences were excited by a single argon-ion laser emitting at 488 nm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号