首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method was developed and validated for determination of aminoflavone (AF) in human plasma. Sample preparation involved a liquid–liquid extraction by the addition of 0.25 mL of plasma with 1.0 mL ethyl acetate containing 50 ng/mL of the internal standard zileuton. The analytes were separated on a Waters X-Terra? MS C18 column using a mobile phase consisting of methanol/water containing 0.45% formic acid (70:30, v/v) and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the AF concentration range of 5–2000 ng/mL in human plasma. The lower limit of quantitation (LLOQ) was 5 ng/mL for AF in human plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical method (<15%). This method was successfully applied to characterize AF plasma concentration-time profile in the cancer patients in a phase I trial.  相似文献   

2.
This paper describes a rapid and sensitive method for the quantitation of 20(S)-protopanaxadiol (PPD) in human plasma based on high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analyte and internal standard (I.S.), ginsenoside Rh2, were extracted from plasma by liquid–liquid extraction and separated on a Zorbax extend C18 analytical column using methanol–acetonitrile-10 mM ammonium acetate (47.5:47.5:5, v/v/v) as mobile phase. Detection was by tandem mass spectrometry using electrospray ionization in the positive ion mode and multiple reaction monitoring (MRM). The assay was linear over the concentration range 0.1–100.0 ng/ml with a limit of detection of 0.05 ng/ml. The method was successfully applied to a clinical pharmacokinetic study in healthy volunteers after a single oral administration of a PPD 25 mg capsule.  相似文献   

3.
A specific, sensitive and rapid method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) was developed for the simultaneous determination of olmesartan (OLM) and hydrochlorothiazide (HCTZ) in human plasma and urine. Solid-phase extraction (SPE) was used to isolate the analytes from biological matrices followed by injection of the extracts onto a C18 column with isocratic elution. Detection was carried out on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring (MRM) mode using negative electrospray ionization (ESI). The method was validated over the concentration range of 1.00–1000 ng/mL and 5.00–5000 ng/mL for OLM in human plasma and urine as well as 0.500–200 ng/mL and 25.0–25,000 ng/mL for HCTZ in human plasma and urine, respectively. Inter- and intra-run precision of OLM and HCTZ were less than 15% and the accuracy was within 85–115% for both plasma and urine. The average extraction recoveries were 96.6% and 92.7% for OLM, and 87.2% and 72.1% for HCTZ in human plasma and urine, respectively. The linearity, recovery, matrix effect and stability were validated for OLM/HCTZ in human plasma and urine.  相似文献   

4.
A novel validated liquid chromatography–tandem mass spectrometry (LC–MS/MS) procedure was developed and fully validated for the simultaneous determination of nicotine-N-β-d-glucuronide, cotinine-N-oxide, trans-3-hydroxycotinine, norcotinine, trans-nicotine-1′-oxide, cotinine, nornicotine, nicotine, anatabine, anabasine and cotinine-N-β-d-glucuronide in human plasma or urine. Target analytes and corresponding deuterated internal standards were extracted by solid-phase extraction and analyzed by LC–MS/MS with electrospray ionization (ESI) using multiple reaction monitoring (MRM) data acquisition. Calibration curves were linear over the selected concentration ranges for each analyte, with calculated coefficients of determination (R2) of greater than 0.99. The total extraction recovery (%) was concentration dependent and ranged between 52–88% in plasma and 51–118% in urine. The limits of quantification for all analytes in plasma and urine were 1.0 ng/mL and 2.5 ng/mL, respectively, with the exception of cotinine-N-β-d-glucuronide, which was 50 ng/mL. Intra-day and inter-day imprecision were ≤14% and ≤17%, respectively. Matrix effect (%) was sufficiently minimized to ≤19% for both matrices using the described sample preparation and extraction methods. The target analytes were stable in both matrices for at least 3 freeze–thaw cycles, 24 h at room temperature, 24 h in the refrigerator (4 °C) and 1 week in the freezer (?20 °C). Reconstituted plasma and urine extracts were stable for at least 72 h storage in the liquid chromatography autosampler at 4 °C. The plasma procedure has been successfully applied in the quantitative determination of selected analytes in samples collected from nicotine-abstinent human participants as part of a pharmacokinetic study investigating biomarkers of nicotine use in plasma following controlled low dose (7 mg) transdermal nicotine delivery. Nicotine, cotinine, trans-3-hydroxycotinine and trans-nicotine-1′-oxide were detected in the particular sample presented herein. The urine procedure has been used to facilitate the monitoring of unauthorized tobacco use by clinical study participants at the time of physical examination (before enrollment) and on the pharmacokinetic study day.  相似文献   

5.
A rapid, sensitive and selective ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method with hydrophilic interaction chromatography has been developed and validated for the simultaneous determination of didanosine and valdidanosine (L-valine amino acid ester prodrug of didanosine) in rat plasma. Solid-phase extraction (SPE) column was employed to extract the analytes from rat plasma, with high extraction recovery (>85%) for both didanosine and valdidanosine. The analytes were then separated by hydrophilic interaction chromatography (HILIC column) and detected by a triple-quadrupole mass spectrometry equipped with an electrospray ionization (ESI) source. The method was linear over the concentration ranges of 2–20,000 ng/mL for didanosine and 4–300 ng/mL for valdidanosine. The lower limit of quantitation (LLOQ) of didanosine and valdidanosine was 2 and 4 ng/mL, respectively. The intra-day and inter-day relative standard deviation (RSD) were less than 15% and the relative errors (RE) were all within 15%. Finally, the validated UPLC–MS/MS method was successfully applied to the pharmacokinetic study after either didanosine or valdidanosine orally administrated to the Sprague–Dawley rats.  相似文献   

6.
A rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of picamilon concentration in human plasma. Picamilon was extracted from human plasma by protein precipitation. High performance liquid chromatography separation was performed on a Venusil ASB C18 column with a mobile phase consisting of methanol ?10 mM ammonium acetate–formic acid (55:45:01, v/v/v) at a flow rate of 0.65 ml/min. Acquisition of mass spectrometric data was performed in selected reaction monitoring mode, using the transitions of m/z 209.0  m/z (78.0 + 106.0) for picamilon and m/z 152.0  m/z (93.0 + 110.0) for paracetamol (internal standard). The method was linear in the concentration range of 1.00–5000 ng/ml for the analyte. The lower limit of quantification was 1.00 ng/ml. The intra- and inter-assay precision were below 13.5%, and the accuracy was between 99.6% and 101.6%. The method was successfully applied to characterize the pharmacokinetic profiles of picamilon in healthy volunteers. This validated LC–MS/MS method was selective and rapid, and is suitable for the pharmacokinetic study of picamilon in humans.  相似文献   

7.
A new simple, rapid, sensitive and accurate quantitative detection method using liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) for the measurement of formononetin (FMN) and daidzein (DZN) levels in rat plasma is described. Analytes were separated on a Supelco Discovery C18 (4.6 × 50 mm, 5.0 μm) column with acetonitrile: methanol (50:50, v/v) and 0.1% acetic acid in the ratio of 90:10 (v/v) as a mobile phase. The method was proved to be accurate and precise at linearity range of 5–100 ng/mL with a correlation coefficient (r) of ≥0.996. The intra- and inter-day assay precision ranged from 1.66–6.82% and 1.87–6.75%, respectively; and intra- and inter-day assay accuracy was between 89.98–107.56% and 90.54–105.63%, respectively for both the analytes. The lowest quantitation limit for FMN and DZN was 5.0 ng/mL in 0.1 mL of rat plasma. Practical utility of this new LC–MS/MS method was demonstrated in a pharmacokinetic study in rats following intravenous administration of FMN.  相似文献   

8.
Ethambutol and pyrazinamide are two first-line anti-tuberculosis drugs. Though they are normally combined for the treatment, their highly different polarity complicates simultaneous liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of these two drugs in human plasma with decent peak shape and retention. Here we report a rapid and robust LC/MS/MS method for the simultaneous determination of these two drugs in human plasma. Human plasma samples, together with the isotopically labeled internal standards were extracted using protein precipitation, and then separated on a Chromolith SpeedROD RP-18e column and detected with mass spectrometry. The mobile phase is 0.1% trifluoroacetic acid in water and 0.1% trifluoroacetic acid in methanol. Addition of trifluoroacetic acid in the mobile phases was found to be able to improve peak shape as well as to increase the retention of ethambutol, thus being able to analyze these two drugs at the same time with both drugs having decent peak shape and enough retention on a C18 column. An atmospheric pressure chemical ionization interface was chosen to reduce ion suppression from sample matrix components and provide high sensitivity. The standard curve range was 10.0–5000 ng/mL for ethambutol and 50.0–25,000 ng/mL for pyrazinamide using a plasma sample volume of 50.0 μL. This method has a very short run time of 3.8 min. The method has been fully validated, and <15% relative standard deviation was obtained for both analytes.  相似文献   

9.
We present a simple, rapid, and sensitive liquid chromatography (LC)–tandem mass spectrometry (MS/MS) method for the simultaneous quantification of rosiglitazone and its two major metabolites via CYP2C8/9, N-desmethyl and p-hydroxy rosiglitazone, in human plasma. The procedure was developed and validated using rosiglitazone-d3 as the internal standard. Plasma samples (0.1 ml) were prepared using a simple deproteinization procedure with 0.2 ml of acetonitrile containing 40 ng/ml of rosiglitazone-d3. Chromatographic separation was carried out on a Luna C18 column (100 mm × 2.0 mm, 3-μm particle size) using an isocratic mobile phase consisting of a 60:40 (v/v) mixture of acetonitrile and 0.1% formic acid(aq). Each sample was run at 0.2 ml/min for a total run time of 2.5 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction-monitoring mode with positive electrospray ionization at m/z 358.1  135.1 for rosiglitazone, m/z 344.2  121.1 for N-desmethyl rosiglitazone, m/z 374.1  151.1 for p-hydroxy rosiglitazone, and m/z 361.1  138.1 for rosiglitazone-d3. The linear ranges of concentration for rosiglitazone, N-desmethyl rosiglitazone, and p-hydroxy rosiglitazone were 1–500, 1–150, and 1–25 ng/ml, respectively, with a lower limit of quantification of 1 ng/ml for all analytes. The coefficient of variation for assay precision was less than 14.4%, and the accuracy was 93.3–112.3%. No relevant cross-talk and matrix effect were observed. This method was successfully applied to a pharmacokinetic study after oral administration of a 4-mg rosiglitazone tablet to healthy male Korean volunteers.  相似文献   

10.
A high throughput and specific method using ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) was developed for the simultaneous determination of diltiazem and its two metabolite (N-desmethyldiltiazem and O-desacetyldiltiazem) in human plasma. A one-step liquid–liquid extraction (LLE) with methyl-t-butyl ether (MTBE) involved for the extraction of diltiazem (DLTZ), metabolites (DMeD and DAcD) and internal standard. Analytes were chromatographed on a ACQUITY UPLC? BEH C18 column (100 mm × 2.1 mm, i.d., 1.7 μm) with isocratic elution at a flow rate of 0.2 mL/min using 10 mM ammonium acetate buffer–acetonitrile (25:75, v/v). The Quattro Premier XE LC–MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Using 300 μL plasma, the method was validated over the concentration range 0.48–639.9 ng/mL for DLTZ and 0.24–320.1 for DMeD and 0.24–320.7 ng/mL for DAcD, with a lower limit of quantification of 0.48 ng/mL for DLTZ and 0.24 ng/mL for metabolites. The intra- and inter-day precision and accuracy were within 10.0%. The recovery was 77.4%, 76.0%, 74.5% and 74.1% for DLTZ, DMeD, DAcD and Ziprasidone, respectively. Total run time was 2.0 min only.  相似文献   

11.
For the first time, a highly sensitive and simple LC–MS/MS method after one-step precipitation was developed and validated for the simultaneous determination of paracetamol (PA), pseudoephedrine (PE), dextrophan (DT) and chlorpheniramine (CP) in human plasma using diphenhydramine as internal standard (IS). The analytes and IS were separated on a YMC-ODS-AQ C18 Column (100 mm × 2.0 mm, 3 μm) by a gradient program with mobile phase consisting of 0.3% (v/v) acetic acid and methanol at a flow rate of 0.30 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer via electrospray ionization in the positive ion mode. The method was validated and linear over the concentration range of 10–5000 ng/mL for PA, 2–1000 ng/mL for PE, 0.05–25 ng/mL for DT and 0.1–50 ng/mL for CP. The accuracies as determined from quality control samples were in range of ?8.37% to 3.13% for all analytes. Intra-day and inter-day precision for all analytes were less than 11.54% and 14.35%, respectively. This validated method was successfully applied to a randomized, two-period cross-over bioequivalence study in 20 healthy Chinese volunteers receiving multicomponent formulations containing 325 mg of paracetamol, 30 mg of pseudoephedrine hydrochloride, 15 mg of dextromethorphan hydrobromide and 2 mg of chlorphenamine maleate.  相似文献   

12.
With the expanded use of the combination of artesunate (AS) and amodiaquine (AQ) for the treatment of falciparum malaria and the abundance of products on the market, comes the need for rapid and reliable bioanalytical methods for the determination of the parent compounds and their metabolites. While the existing methods were developed for the determination of either AS or AQ in biological fluids, the current validated method allows simultaneous extraction and determination of AS and AQ in human plasma. Extraction is carried out on Supelclean LC-18 extraction cartridges where AS, its metabolite dihydroartemisinin (DHA) and the internal standard artemisinin (QHS) are separated from AQ, its metabolite desethylamodiaquine (DeAQ) and the internal standard, an isobutyl analogue of desethylamodiaquine (IB-DeAQ). AS, DHA and QHS are then analysed using Hypersil C4 column with acetonitrile–acetic acid (0.05 M adjusted to pH 5.2 with 1.00 M NaOH) (42:58, v/v) as mobile phase at flow rate 1.50 ml/min. The analytes are detected with an electrochemical detector operating in the reductive mode. Chromatography of AQ, DeAQ and IB-DeAQ is carried out on an Inertsil C4 column with acetonitrile–KH2PO4 (pH 4.0, 0.05 M) (11:89, v/v) as mobile phase at flow rate 1.00 ml/min. The analytes are detected by an electrochemical detector operating in the oxidative mode. The recoveries of AS, DHA, AQ and DeAQ vary between 79.1% and 104.0% over the concentration range of 50–1400 ng/ml plasma. The accuracies of the determination of all the analytes are 96.8–103.9%, while the variation for within-day and day-to-day analysis are <15%. The lower limit of quantification for all the analytes is 20 ng/ml and limit of detection is 8 ng/ml. The method is sensitive, selective, accurate, reproducible and suited particularly for pharmacokinetic study of AS–AQ drug combination and can also be used to compare the bioavailability of different formulations, including a fixed-dose AS–AQ co-formulation.  相似文献   

13.
We present herein a sensitive and selective assay for the determination of oxycodone and its main metabolites, oxymorphone, noroxycodone and noroxymorphone in human plasma, using column-switching and liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS). Sample preparation comprised protein precipitation with perchloric acid. After neutralization, the supernatant was injected without any evaporation step onto a polymeric, pH-resistant cartridge (HySphere Resin GP 10–12 μm) for sample clean-up (Prospekt II). The latter operation was achieved by using alkaline conditions to ensure retention of analytes and methanol for matrix interference removal. More than two hundred plasma samples could be analyzed with a single cartridge. Analytes were desorbed in the backflush mode and were separated on a conventional reversed phase column (XTerra MS 4.6 × 50 mm, 3.5 μm), using an acidic mobile phase (i.e. containing 0.1% of formic acid). Mass spectrometric detection was achieved with a 4000 Q TRAP equipped with an atmospheric pressure chemical ionization (APCI) source, in positive ionization mode, operated in the selected reaction monitoring mode (SRM). Starting from a plasma volume of 250 μl, quantification ranges were 25–10,000 pg/ml for OXM and NOXM and 50–10,000 pg/ml for OXC and NOXC. Accuracy was found to be within 98% and 108% and precision better than 7%. Replicate determination of incurred or study samples ensured the method to be reproducible and usable for clinical studies.  相似文献   

14.
A highly sensitive and selective LC–MS/MS method was developed and validated for the determination of dauricine in human plasma, using protopine as internal standard (IS). The analyte and IS were extracted by liquid–liquid extraction and analyzed by LC–MS/MS. Chromatographic separation was performed on Agilent TC-C18 column with a mobile phase of methanol–water–glacial acetic acid (60:40:0.8, v/v/v) at a flow rate of 0.7 mL/min. Detection was performed on a triple quadrupole tandem mass spectrum by multiple reaction monitoring (MRM) mode using the electrospray ionization technique in positive mode. The method was linear over the concentration range of 1–200 ng/mL. The lower limit of quantification (LLOQ) was 1 ng/mL in human plasma with acceptable precision and accuracy. The intra- and inter-day precision was less than 5.9% determined from quality control (QC) samples at concentrations of 2.0, 20.0 and 160 ng/mL, and the accuracy was within ±9.9%. This method was successfully applied for the evaluation of pharmacokinetics of dauricine after oral doses of 100, 300 and 600 mg phenolic alkaloids of menispermum dauricum tablet (PAMDT) to 12 Chinese healthy volunteers.  相似文献   

15.
A method for the simultaneous determination of 1-octacosanol and 1-triacontanol and their main metabolites in rat plasma was developed. The procedure involved ethanolic NaOH saponification of the sample, acidification, liquid–liquid extraction, and derivatization of the analytes to its trimethylsilylether/ester, followed analysis by gas chromatography–mass spectrometry (GC–MS) in selected ion monitoring (SIM) mode. Quantification was performed by the internal standard method using betulin. The method had a good linearity over the range 8.4–540 ng/ml (r  0.998) and showed an excellent intra-day (R.S.D. = 0.59–3.06%) and inter-day (R.S.D. = 2.99–5.22%) precision according to the acceptance criteria. The detection limits ranged between 1.32 and 3.47 ng/ml. The method was applied successfully to study the total plasmatic concentration of 1-octacosanol, octacosanoic acid, 1-triacontanol, and triacontanoic acid, after an oral dose of policosanols mixture, using plasma samples of 100 μl.  相似文献   

16.
A rapid and sensitive bioassay based on liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the simultaneous determination of four isomeric escin saponins (escin Ia, escin Ib, isoescin Ia and isoescin Ib) in human plasma has been developed and validated. Sample preparation of plasma after addition of telmisartan as internal standard (I.S.) involved solid-phase extraction (SPE) on C18 cartridges. Separation was based on reversed phase chromatography using gradient elution with methanol–acetonitrile (50:50, v/v) and 10 mM ammonium acetate solution (pH 6.8). MS/MS detection in the positive ion mode used multiple reaction monitoring of the transition at m/z 1113.8  807.6. Stability issues with the four saponins required the addition of formic acid to plasma samples prior to storage at ?80 °C and analysis within 30 days. The method was linear at concentrations up to 10 ng/mL with correlation coefficients > 0.996 for all analytes. The lower limit of quantitation (LLOQ) for all four saponins was 33 pg/mL. Intra- and inter-day precisions (as relative standard deviation) were all <15% and accuracies (as relative error) in the range ?5.3% to 6.1%. The method was successfully applied to a pharmacokinetic study of escins in healthy volunteers after oral administration of sodium aescinate tablets containing 60 mg escin saponins.  相似文献   

17.
Vincristine is a natural vinca alkaloid widely used in paediatric cancer treatment. Vincristine pharmacokinetics has been already studied, but few data are available in paediatric populations. A sensitive and specific liquid chromatography–tandem mass spectrometry (LC/MS/MS) method was developed for the quantification of vincristine in plasma in order to investigate pharmacokinetics in a paediatric population. Two hundred microliters of plasma was added to vinblastine, used as internal standard. Chromatographic separation was achieved on a C8 HPLC column (Phenomenex Luna 50 mm × 2.0 mm, 3.0 μm) with a mobile phase gradient at a flow rate of 0.2 ml/min. Quantification was performed using the transition of 825.4  765.4 (m/z) for vincristine and 811.4  751.4 (m/z) for vinblastine. Chromatographic separation was achieved in 8 min. The limit of quantification was 0.25 ng/ml with a precision of 10.2% and an accuracy of 99.6%. The calibration curve was linear up to 50.0 ng/ml. Intra-day precision and accuracy ranged from 6.3% to 10% and from 91.9% to 100.8%, respectively. Inter-assay precision and accuracy ranged from 3.8% to 9.7% and from 93.5% to 100.5%, respectively. No significant matrix effect was observed for vincristine. A rapid, specific and sensitive LC/MS/MS method for quantification of vincristine in human plasma was developed and is now successfully applied for pharmacokinetic studies in paediatric patients.  相似文献   

18.
OBJECTIVESTo determine whether poly (ADP-ribose) polymerase-1/2 (PARP-1/2) inhibition enhances radiation-induced cytotoxicity of pancreatic adenocarcinoma in vitro and in vivo, and the mechanism by which this occurs.MethodsPancreatic carcinoma cells were treated with ABT-888, radiation, or both. In vitro cell viability, apoptosis, and PARP activity were measured. Orthotopic xenografts were generated in athymic mice and treated with ABT-888 (25 mg/kg), radiation (5 Gy), both, or no treatment. Mice were monitored with bioluminescence imaging.RESULTSIn vitro, treatment with ABT-888 and radiation led to higher rates of cell death after 8 days (P < .01). Co-treatment with 5 Gy and 1, 10 or 100 μmol/l of ABT-888 led to dose enhancement factors of 1.29, 1.41 and 2.36, respectively. Caspase activity was not significantly increased when treated with ABT-888 (10 μmol/l) alone (1.28-fold, P = .08), but became significant when radiation was added (2.03-fold, P < .01). PARP activity increased post-radiation and was abrogated following co-treatment with ABT-888. In vivo, treatment with ABT-888, radiation or both led to tumor growth inhibition (TGI) of 8, 30 and 39 days, and survival at 60 days of 0%, 0% and 40%, respectively.CONCLUSIONSABT-888 with radiation significantly enhanced tumor response in vitro and in vivo. ABT-888 inhibited PAR protein polymerization resulting in dose-dependent feedback up-regulation of PARP and p-ATM suggesting increased DNA damage. This translated into enhancement in TGI and survival with radiation in vivo. In vitro PAR levels correlated with levels of tumor apoptosis suggesting potential as a predictive biomarker. These data are being used to support a Phase I study in locally advanced pancreatic cancer.  相似文献   

19.
A simple sensitive and robust method for simultaneous determination of citalopram and desmethylcitalopram was developed using liquid chromatography tandem mass spectrometry (LC–MS/MS). A 200 μL aliquot of plasma sample was employed and deproteinized with methanol and desipramine was used as the internal standard. After vortex mixing and centrifugation, the supernatant was diluted with water (1:1, v/v) and then directly injected to analysis. Analytes were separated by a Zorbax XDB C18 column with the mobile phase composed of acetonitrile and water (30:70, v/v) with 0.25% formic acid and monitored in MRM mode using a positive electrospray source with tandem mass spectrometry detection. The total run time was 3.5 min. The dynamic range was 0.2–100 ng/mL for citalopram and 0.25–50 ng/mL for desmethylcitalopram, respectively. Compared to the best existing literatures for plasma samples, the same LOQ for CIT (0.5 ng/mL) and lower LOQ for DCIT (0.25 vs 5 ng/mL) were reached, and less sample preparation steps and runtime (3.5 vs 10 min) were taken for our method. Accuracy and precision was lower than 8% and lower than 11.5% for either target. Validation results and its application to the analysis of plasma samples after oral administration of citalopram in healthy Chinese volunteers demonstrated the method was applicable to pharmacokinetic studies.  相似文献   

20.
A liquid chromatography–electrospray ionization tandem mass spectrometry (HPLC–ESI-MS/MS) method for the determination of andrographolide in human plasma was established. Dehydroandrographolide was used as the internal standard (I.S.). The plasma samples were deproteinized with methanol and separated on a Hanbon C18 column with a mobile phase of methanol–water (70:30, v/v). HPLC–ESI-MS/MS was performed in the selected ion monitoring (SIM) mode using target ions at [M?H2O–H]?, m/z 331.1 for andrographolide and [M?H]?, m/z 331.1 for the I.S. Calibration curve was linear over the range of 1.0–150.0 ng/mL. The chromatographic separation was achieved in less than 6.5 min. The lower limits of quantification (LLOQ) was 1.0 ng/mL. The intra and inter-run precisions were less than 6.95 and 7.22%, respectively. The method was successfully applied to determine the plasma concentrations of andrographolide in Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号