首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Underivatized oligogalacturonic acids with a degree of polymerization (DP) ranging from 2 to 50 have been separated for the first time on a high-performance CarboPac PA1 pellicular anion-exchange stationary phase column. Baseline separation of these pectic fragments was accomplished using a nonlinear gradient of pH 6 potassium oxalate buffer as the mobile phase. Acetate buffer linear gradients were also useful as mobile phases, but only for separations of oligogalacturonic acids that were soluble in this solvent (DP less than 20). Additionally, oligogalacturonic acid separations were accomplished on a lower capacity AS4A stationary phase column. Triple pulse amperometric detection was selective, sensitive, and reproducible, nevertheless, oligogalacturonic acid response factors were affected by DP and compositional changes in the mobile phase.  相似文献   

2.
Monoliths represent a special class of chromatographic supports. In contrast to other stationary phases, they consist of a single piece of highly porous material through which a sample is mainly transported by convection. As a consequence, monoliths enable fast separations and exhibit flow-unaffected properties, which make them attractive for purification of macromolecules like proteins or DNA. In this work, methacrylate-based monolithic columns with the bed volume up to 8000 ml are characterized. They perform high-resolution separations of several hundreds of grams of proteins per hour by utilizing liter per minute flow rates. They are incompressible under these operating conditions and resistant to strong alkaline conditions.  相似文献   

3.
Cation-exchange columns were found to be stable when used at high pH and high temperature for high-performance liquid chromatographic separations of carbohydrates and carbohydrate derivatives. Pulsed amperometric detection and refractive index detection were found to be suitable detection modes with these cation-exchange columns. Significant differences in carbohydrate separation selectivity were observed between cation-exchange and anion-exchange columns.  相似文献   

4.
Sequence-dependent cytotoxicity of second-generation oligonucleotides   总被引:1,自引:1,他引:0  
In this study, we have examined the potential of second-generation antisense chimeric 2′-O-(2-methoxy)ethyl/DNA phosphorothioate oligonucleotides (ONs) to affect cell growth through non-antisense mechanisms. Evaluation of a series of ONs demonstrated that only a small number were cytotoxic at concentrations close to those required for antisense activity. Toxicity of the ONs appeared to be sequence dependent and could be affected by base and backbone modifications. Caspase-3 activation occurs with some ONs and it is most likely secondary to necrosis rather than apoptosis, since cells treated with toxic ONs did not show chromatin condensation, but did exhibit high-extracellular lactate dehydrogenase activity. Caspase-3 activation does not correlate with and appears not to be required for the inhibition of cell proliferation. Toxicity was only observed when ONs were delivered intracellularly. The mechanism by which one of the most cytotoxic ON produces cytotoxicity was investigated in more detail. Treatment with the cytotoxic ON caused disruption of lysosomes and Pepstatin A, a specific inhibitor of aspartic proteases, reduced the cytotoxicity of the ON. Reduction of lysosomal aspartic protease cathepsin D by prior treatment with cathepsin D-specific antisense ON did not attenuate the cytotoxicity, suggesting that other aspartic proteases play a crucial role in the cellular proliferation inhibition by ONs.  相似文献   

5.
There is a demand of novel high resolution separation media for separation of complex mixtures, particularly biological samples. One of the most flexible techniques for development of new separation media currently is synthesis of the continuous bed (monolithic) stationary phases. In this study the capillary format gradient stationary phases were formed using continuous bed (monolith) polymerization in situ. Different reversed-phase stationary phase gradients were tailored and their resolution using capillary liquid chromatography and capillary electrochromatography at isocratic mobile phase conditions was evaluated. It is demonstrated, that efficiency and resolution of the gradient stationary phases can be substantially increased comparing to the common (isotropic) stationary phases. The proposed formation approach of the gradient stationary phase is reproducible and compatible with the capillary format or microchip format separations. It can be easily automated for the separation optimizations or mass production of the capillary columns or chips.  相似文献   

6.
There is a demand of novel high resolution separation media for separation of complex mixtures, particularly biological samples. One of the most flexible techniques for development of new separation media currently is synthesis of the continuous bed (monolithic) stationary phases. In this study the capillary format gradient stationary phases were formed using continuous bed (monolith) polymerization in situ. Different reversed-phase stationary phase gradients were tailored and their resolution using capillary liquid chromatography and capillary electrochromatography at isocratic mobile phase conditions was evaluated. It is demonstrated, that efficiency and resolution of the gradient stationary phases can be substantially increased comparing to the common (isotropic) stationary phases. The proposed formation approach of the gradient stationary phase is reproducible and compatible with the capillary format or microchip format separations. It can be easily automated for the separation optimizations or mass production of the capillary columns or chips.  相似文献   

7.
This work describes the application of the fully automated high-performance liquid chromatographic system to the analysis of PCR-amplified products. Efficient separations of both DNA restriction fragments and PCR products were performed using an anion-exchange DEAE-NPR column, packed with 2.5-μm nonporous particles. The automated HPLC method was employed for the separation, quantitation, and purification of PCR products in less than 10 min in a single step.  相似文献   

8.
Oligonucleotides (ONs) are gaining increasing importance as a promising novel class of biopharmaceuticals. Thanks to their fundamental role in gene regulation, they can be used to develop custom‐made drugs (also called N‐to‐1) able to act on the gene expression at pre‐translational level. With recent approvals of ON‐based therapeutics by the Food and Drug Administration (FDA), a growing demand for high‐quality chemically modified ONs is emerging and their market is expected to impressively prosper in the near future. To satisfy this growing market demand, a scalable and economically sustainable ON production is needed. In this paper, the state of the art of the whole ON production process is illustrated with the aim of highlighting the most promising routes toward the auspicated market‐size production. In particular, the most recent advancements in both the upstream stage, mainly based on solid‐phase synthesis and recombinant technology, and the downstream one, focusing on chromatographic techniques, are reviewed. Since ON production is projected to expand to the large scale, automatized multicolumn countercurrent technologies will reasonably be required soon to replace the current ones based on batch single‐column operations. This consideration is supported by a recent cutting‐edge application of continuous chromatography for the ON purification.  相似文献   

9.
During chemical RNA synthesis, many undesired products may be formed. In addition to the "n-x" sequences, depurination products, and incompletely deprotected oligonucleotides, linkage isomers may form during condensation and/or deprotection of the synthetic products. Under acidic conditions, bond migration may alter normal 3'-5' diesters to aberrant 2'-5' diesters. This results in isomers that are difficult to identify by MS and LC-MS techniques because the isomers have identical masses. HPLC methods for identification of these isomers have not advanced because the isomers are not expected to exhibit differences in hydrophobicity that allow resolution by reversed-phase columns. Neither are changes in ionic interactions anticipated for these isomers that would allow resolution by ion exchange methods. We observed that chromatography on pellicular anion exchange phases, but not on porous anion exchange phases, completely resolves oligonucleotides with very slight conformation differences (e.g., DNA vs. RNA of identical sequence). Because incorporation of 2'-5' linkages in RNA will alter solution conformation slightly, we considered that this pellicular ion exchanger might also allow resolution of identical RNA sequences harboring aberrant 2'-5' linkages from those lacking aberrant 2'-5' linkages. Using the nonporous DNAPac PA200 column, we demonstrated a chromatographic procedure for resolving synthetic RNA with aberrant linkages from their normally linked counterparts. Under certain conditions, aberrant isomers are not completely resolved from those containing only normal linkages. Therefore, we also developed an independent linkage-confirming method using a 5'-3' exonuclease. This enzyme produces incomplete digestion products during digestion of synthetic RNA containing aberrant 2'-5' linkages, and these are readily resolved by DNAPac PA200 chromatography.  相似文献   

10.
The efficient immobilization of antibodies on monolithic support is one of the most critical steps when preparing immunoaffinity supports. In this work, the ADECA (amino density estimation by colorimetric assay) method was adapted to tridimensional supports (in a dynamic mode) and proved to be efficient to characterize the antibodies grafting efficiency on 15.3±0.9mg porous glycidyl methacrylate (GMA)-co-ethylene dimethacrylate (EDMA) monolithic columns. The amount of grafted antibodies measured in situ on the monolith by ADECA (8.2±0.2μg of antibodies per milligram of monolith) was consistent with values obtained by bicinchoninic acid assay (BCA) after crushing the monolith. ADECA was shown to be less time-consuming and more versatile than BCA. The ADECA method was further implemented to thoroughly study and optimize the antibody grafting conditions (influence of pH and kinetics of the grafting step) on GMA-based monoliths and to check the covalent nature of the antibody/surface linking and its stability. Using the total amount of grafted antibodies and the amount of recognized antigen, we found that 65±6% of antibodies were able to capture their antigen. Finally, the grafting of Fab and F(ab')(2) fragments demonstrated that no significant improvement of the global binding capacity of the monolith was obtained.  相似文献   

11.
The widespread utilization of gene silencing techniques, such as antisense, is impeded by the poor cellular delivery of oligonucleotides (ONs). Rational design of carriers for enhanced ON delivery demands a better understanding of the role of the vector on the extent and time course of antisense effects. The aim of this study is to understand the effects of polymer molecular weight (MW) and ON backbone chemistry on antisense activity. Complexes were prepared between branched polyethyleneimine (PEI) of various MWs and ONs of phosphodiester and phosphorothioate chemistries. We measured their physico-chemical properties and evaluated their ability to deliver ONs to cells, leading to an antisense response. Our key finding is that the antisense activity is not determined solely by PEI MW or by ON chemistry, but rather by the interplay of both factors. While the extent of target mRNA down-regulation was determined primarily by the polymer MW, dynamics were determined principally by the ON chemistry. Of particular importance is the strength of interactions between the carrier and the ON, which determines the rate at which the ONs are delivered intracellularly. We also present a mathematical model of the antisense process to highlight the importance of ON delivery to antisense down-regulation.  相似文献   

12.
To understand the parameters required for designing potent and specific antisense C-5 propynyl-pyrimidine-2'-deoxyphosphorothioate-modified oligonucleotides (C-5 propyne ONs), we have utilized a HeLa line that stably expresses luciferase under tight control of a tetracycline-responsive promoter. Using this sensitive and regulatable cell-based system we have identified five distinct antisense ONs targeting luciferase and have investigated the role that ON length, target mismatches, compound stability and intracellular RNA levels play in affecting antisense potency. We demonstrate that C-5 propyne ONs as short as 11 bases retained 66% of the potency demonstrated by the parent 15 base compound, that a one base internal mismatch between the antisense ON and the luciferase target reduced the potency of the antisense ON by 43% and two or more mismatches completely inactivated the antisense ON and that C-5 propyne ONs have a biologically active half-life in tissue culture of 35 h. In addition, by regulating the intracellular levels of the luciferase mRNA over 20-fold, we show that the potency of C-5 propyne ONs is unaffected by changes in the expression level of the target RNA. These data suggest that low and high copy messages can be targeted with equivalent potency using C-5 propyne ONs.  相似文献   

13.
Recovery of antibodies with Protein A affinity chromatography columns has become the standard for the biotechnology industry. Membrane affinity chromatography has not yet experienced extensive application due to the lower capacity of membrane supports compared to chromatographic beads. In this work, new affinity membranes endowed with an interesting binding capacity for human IgG are studied in view of their application in the capturing step of a monoclonal antibody production process. The membranes have been extensively tested with pure IgG solutions and with a cell culture supernatant containing IgG1. The effects of feed flow rate and IgG concentration on the separation performances have been studied in detail, considering in particular binding capacity, selectivity and recovery. These new high capacity affinity membranes appear good candidates to avoid the throughput limitations and other well-known drawbacks of traditional bead-based chromatographic columns.  相似文献   

14.
Antisense and antigene oligonucleotides (ONs) are attractive drugs for gene therapy, but major limiting factors for their routine use are inefficient cellular uptake and low accessibility to the target sites. Adding various lipophilic conjugates to the ON improves intracellular delivery as has been previously reported.We studied the cellular delivery of various ON modifications, as well as their cytosolic and nuclear distribution in mammalian Hep2-EGFP-NLS cell line. We compared uptake efficacy of ON and LNA, both conjugated with cholesterol at the 5′ end. All ONs were 3′ labeled with fluorescent Cy5 dye. We made a comparison of the ONs uptake efficacy and the kinetics, both adding ONs to the culture medium, and using streptolysin-O (SL-O) permeabilization.The cellular uptake of each ON used in this study was visualized by fluorescent microscopy. We confirmed the results by FACS analysis. We determined the ratio between initial ON-chol concentration (0.4 μM) and the final amount in nucleus.SL-O can highly improve kinetics of ON delivery; not only into the cytoplasm but also to the nucleus, the presumed site of antigene ON action. The most effective nuclear uptake was observed when ON conjugated with cholesterol (ON-chol) and SL-O was used. Nuclear distribution of ON was reached within few minutes. In contrast, ON simply added to the medium reached cytoplasm only and the process of delivery took several hours. (Mol Cell Biochem 276: 61–69, 2005)  相似文献   

15.
The chromatographic behavior of some purines and pyrimidines on a monolithic Chromolith Performance Si column under normal-phase high-performance liquid chromatography mode has been studied. Column pressure, column efficiency and selectivity of Chromolith Performance Si column were compared to those of conventional spherical 5 microm silica packed columns Econosphere Silica and Zorbax Rx-SIL. The investigation has shown that application of Chromolith Performance Si column for analysis of polar solutes can reduce the separation time without sacrificing column efficiency and selectivity. Improvement of the monolithic silica column efficiency for polar solutes is observed when ternary mobile phases (mixtures of hexane-isopropanol with ethylene glycol, water or acetonitrile) are applied.  相似文献   

16.
Supermacroporous monolithic acrylamide (AAm)-based cryogels were prepared by radical cryo-polymerizaton (polymerization in the moderately frozen system) of AAm with functional monomers and cross-linker N,N'-methylene-bis-acrylamide (MBAAm). Electron microscopy studies revealed supermacroporous structure of the developed cryogels with pore size of 5-100 microm. Cryogel porosity depended on cryo-polymerization conditions. More than 90% of the monolithic bed volume is the interconnected supermacropores filled with water and less than 10% of the monolithic volume is pore walls. The total protein binding capacity (lysozyme in the case of immobilized metal affinity chromatography (IMAC) column and bovine serum albumin (BSA) in the case of anion-exchange (AE) column) was independent of the flow rates till 600 cm/h. Chromatographic behavior of E. coli cells when a cell suspension was applied to ion-exchange cryogel columns depended on both the density of functional ligand and the porosity of the cryogel.  相似文献   

17.
Kren BT  Wong PY  Steer CJ 《DNA Repair》2003,2(5):531-546
Site-specific single-nucleotide changes in chromosomal DNA of eukaryotic cells have been achieved using chimeric RNA/DNA oligonucleotides (ONs) and short single-stranded (SS) ONs. However, a variety of human diseases originate from single-point mutations in the genome of mitochondrial DNA. We previously demonstrated that extracts from highly purified rat liver mitochondria possess the essential enzymatic activity to mediate targeted single-nucleotide changes using chimeric ONs in vitro. However, different factor(s) and/or mechanism(s) appear to be involved in SS and RNA/DNA ON mediated DNA repair. Because mitochondria are deficient in certain factors involved in nuclear DNA repair pathways, we investigated whether mitochondria possess the enzymatic machinery for SS ON mediated DNA alterations. Using in vitro DNA repair assays based on mutagenized plasmids and a bacterial read-out system, SS ONs were designed to correct the point mutations in the genes encoded by the different plasmids. In this system, protein extracts from purified rat liver mitochondria and nuclei catalyzed similar levels of site-specific nucleotide modifications using SS ONs. Interestingly, extracts isolated from quiescent liver mediated significantly higher conversion rates than those isolated from regenerating liver. The results suggest that mitochondria contain the factors necessary for correction of single-point mutations by SS ONs. In addition, at least some are different than those required for DNA repair by RNA/DNA ONs. Moreover, correction with SS ONs appears to occur one strand at a time suggesting that repair of the DNA substrate involves strand transfer. The ability of unmodified SS ONs to mediate targeted alteration of the mitochondrial genome may provide a new tactic for treatment of certain mitochondrial-based diseases.  相似文献   

18.
Based on the monolithic silica gel materials with hierarchical pore structure and on the SPE devices (MonoTip) developed thereof, a trypsin-immobilized monolithic silica in a pipette tip (MonoTip Trypsin) suitable for digesting proteins has been newly developed. The surface of monolithic silica fixed into the tip was chemically modified with trypsin via an aminopropyl group. Trypsin-immobilized monolith successfully performed a rapid digestion of reduced and alkylated proteins with only a few times pipetting operation for the pre-treatment procedure of chromatographic analysis. The novel solid-phase digestion tool using monolithic silica allows a high-throughput trypsin proteolysis of bio-substances in proteomics.  相似文献   

19.
Based on the monolithic silica gel materials with hierarchical pore structure and on the SPE devices (MonoTip®) developed thereof, a trypsin-immobilized monolithic silica in a pipette tip (MonoTip® Trypsin) suitable for digesting proteins has been newly developed. The surface of monolithic silica fixed into the tip was chemically modified with trypsin via an aminopropyl group. Trypsin-immobilized monolith successfully performed a rapid digestion of reduced and alkylated proteins with only a few times pipetting operation for the pre-treatment procedure of chromatographic analysis. The novel solid-phase digestion tool using monolithic silica allows a high-throughput trypsin proteolysis of bio-substances in proteomics.  相似文献   

20.
The chromatographic behavior of some purines and pyrimidines on a monolithic Chromolith Performance Si column under normal-phase high-performance liquid chromatography mode has been studied. Column pressure, column efficiency and selectivity of Chromolith Performance Si column were compared to those of conventional spherical 5 μm silica packed columns Econosphere Silica and Zorbax Rx-SIL. The investigation has shown that application of Chromolith Performance Si column for analysis of polar solutes can reduce the separation time without sacrificing column efficiency and selectivity. Improvement of the monolithic silica column efficiency for polar solutes is observed when ternary mobile phases (mixtures of hexane–isopropanol with ethylene glycol, water or acetonitrile) are applied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号