首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
In recent animal studies, several novel oxime compounds that are better than 2-PAM as antidotes against selected organophosphate (OP) nerve agents have been identified. The purpose of this study was to develop and validate a liquid chromatographic–mass spectrometric (LC–MS) method for analysis of the bis-pyridinium oxime ICD-585 (1-(2-hydroxyiminomethylpyridinium)-3-(4-carbamoylpyridinium)-propane) in plasma and to establish the utility of the method in a guinea pig model. Calibration curves were prepared using ICD-585-spiked plasma at concentrations from 0.156 to 10 μg/ml. Curves were run over a 1-month time frame and a total of 13 (n = 13) were generated. The lower limit of quantification (LLOQ) was determined to be 0.216 μg/ml. Intra- and inter-day variability was assessed by studying precision and accuracy. For intra-day studies, data from the precision determinations indicated that the % CV's ranged from 4.28 to 14.98%. The % error in the accuracy assessments ranged from ?8.73 to 4.61%. For inter-day studies, precision data ranged from 3.53 to 13.20%. The % error in the accuracy assessments ranged from 0.39 to 13.77%. Room temperature, freeze–thaw and autosampler stability was also examined. For all 3 stability studies, the compound remained within ±15% of the initial analysis. Application of the method was demonstrated by analyzing samples from guinea pigs challenged with sarin (GB) or cyclosarin (GF) (1× LD50) followed with intramuscular ICD-585 (58 μM/kg, 21.8 mg/kg). At 55 min after oxime administration, mean (±SD) plasma concentrations were 15.98 (±4.88) μg/ml and 14.57 (±3.70) μg/ml in GB- and GF-exposed animals, respectively. In summary, studies have been carried out to verify the sensitivity, precision and accuracy of the assay as well as the stability of the analyte under various conditions. The method has been demonstrated to be applicable to the analysis of plasma from nerve agent-exposed guinea pigs.  相似文献   

2.
Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC–MS) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC–MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC–MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC–MS, and iTRAQ®–LC–MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27 ± 5.22, 21.18 ± 10.94, and 18.34 ± 14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39 ± 5.35, 6.23 ± 3.84, and 35.37 ± 29.42. Both GC–MS and iTRAQ®–LC–MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.  相似文献   

3.
A rapid liquid chromatographic–tandem mass spectrometric (LC–MS/MS) multi-residue method for the simultaneous quantitation and identification of sixteen synthetic growth promoters and bisphenol A in bovine milk has been developed and validated. Sample preparation was straightforward, efficient and economically advantageous. Milk was extracted with acetonitrile followed by phase separation with NaCl. After centrifugation, the extract was purified by dispersive solid-phase extraction with C18 sorbent material. The compounds were analysed by reversed-phase LC–MS/MS using both positive and negative ionization and operated in multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for unambiguous confirmation. Total chromatographic run time was less than 10 min for each sample. The method was validated at a level of 1 μg L?1. A wide variety of deuterated internal standards were used to improve method performance. The accuracy and precision of the method were satisfactory for all analytes. The confirmative quantitative liquid chromatographic tandem mass spectrometric (LC–MS/MS) method was validated according to Commission Decision 2002/657/EC. The decision limit (CCα) and the detection capability (CCβ) were found to be below the chosen validation level of 1 μg L?1 for all compounds.  相似文献   

4.
A new simple, rapid, sensitive and accurate quantitative detection method using liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) for the measurement of formononetin (FMN) and daidzein (DZN) levels in rat plasma is described. Analytes were separated on a Supelco Discovery C18 (4.6 × 50 mm, 5.0 μm) column with acetonitrile: methanol (50:50, v/v) and 0.1% acetic acid in the ratio of 90:10 (v/v) as a mobile phase. The method was proved to be accurate and precise at linearity range of 5–100 ng/mL with a correlation coefficient (r) of ≥0.996. The intra- and inter-day assay precision ranged from 1.66–6.82% and 1.87–6.75%, respectively; and intra- and inter-day assay accuracy was between 89.98–107.56% and 90.54–105.63%, respectively for both the analytes. The lowest quantitation limit for FMN and DZN was 5.0 ng/mL in 0.1 mL of rat plasma. Practical utility of this new LC–MS/MS method was demonstrated in a pharmacokinetic study in rats following intravenous administration of FMN.  相似文献   

5.
An LC–MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3′,5′-monophosphate (cGMP) in human plasma. The LC–MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC–MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, 13C10,15N5-cGMP, which was biosynthesized in-house, was used in the LC–MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6–10.1% CV and ?3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6–8.1% CV and ?2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9–27.1% CV and ?4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1–39.5% CV and ?30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R2 = 0.197, P = 0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5–20 ng/mL. The LC–MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.  相似文献   

6.
A LC–MS/MS method was developed and validated for determination of nucleoside analog (NA) in rat plasma. The method run time was 6 min and the limit of quantification (LOQ) was estimated at 100 pg/mL. The extraction procedure consisted on plasma samples protein precipitation with an acetonitrile solution which contained the stable isotope labeled internal standard (IS). Chromatography was performed on a newly developed C16 column (150 mm × 4.6 mm, 5 μm) in order to avoid the use ion pair salts. The samples were eluted at 0.8 mL/min with a gradient of mobile phase made of water and acetonitrile both acidified with 0.5% acetic acid and 0.025% trifluoroacetic acid (TFA). A tandem mass spectrometer was used as a detector for quantitative analysis. Intra-run and inter-run precision and accuracy within ±15% were achieved during a 3-run validation for quality control samples at four concentration levels in rat plasma, over a concentration ranging between 0.1 and 1000 ng/mL. The data indicate that our LC–MS/MS assay is an effective method for the pharmacokinetics study of NA in rat plasma.  相似文献   

7.
A simple and sensitive validated LC–MS/MS analytical method was used for determination of curcumin in rat plasma, using nimesulide as internal standard. Analyses were performed on an Agilent LC–MS/MS system using a Chromolith rod? and isocratic elution with acetonitrile:10 mM ammonium acetate buffer (pH 3.5) (80:20, v/v) at a flow rate of 0.8 ml/min with a total run time of 3 min and an overall recovery of 77.15%. A triple quadrupole mass spectrometer, equipped with an electrospray ionization interface, operated in the negative mode was used. Calibration curve in plasma spiked with varying concentration of curcumin were linear over the concentration range of 10–2000 ng/ml with determination coefficient >0.99. The lower limit of quantification was 10 ng/ml. Intra and inter-day variability's (RSD) for extraction of curcumin from plasma were less than 10% and 15% respectively and accuracy was 102.43–108.5%. Multiple reaction monitoring was used to monitor the transition for curcumin (m/z; 367/217 [M?H]?) and IS (m/z; 307/229). The method was applied for determining curcumin concentration in plasma after peroral administration of 50 mg/kg of free curcumin (C-S) or curcumin loaded solid lipid nanoparticles (C-SLNs) to rats. Results established selectivity and suitability of the method for pharmacokinetic studies of curcumin from C-SLNs.  相似文献   

8.
In patients with carcinoid disease, urinary concentration of the serotonin metabolite 5-hydroxyindole acetic acid (5-HIAA) is currently used to monitor disease progression or response to treatment as it is the metabolic end-product resulting from free and stored serotonin turnover. However, due to the undignified, cumbersome and error-prone nature of 24-h urine collections, there is constant pressure to replace them. It has been demonstrated using high performance liquid chromatography (HPLC) with fluorescence detection technology that plasma can achieve this, with the added advantage that it can be used for diagnostic purposes also. Here we describe a much simpler method using liquid chromatography–tandem mass spectrometry (LC–MS/MS) that is twice as fast as a HPLC method currently in routine use. The sample preparation protocol requires 50 μL of plasma and a simple protein precipitation step facilitated by acetonitrile. Chromatography was performed on a Phenomenex C18 Security Guard? column coupled to a SIELC Primesep B reversed-phase, anion-exchange dual chemistry column and methanolic mobile phase gradient elution. Eluant was directly connected to a Waters® Quattro Premier? XE tandem mass spectrometer operating in positive ion mode. We detected multiple reaction monitoring transitions m/z 191.9 > 145.6 and 193.9 > 147.6 for 5-HIAA and d2-5-HIAA respectively, which co-eluted at 2.1 min. Ion suppression was negligible, recovery from spiked plasma was 103% (range 97–113%) and the method showed good linearity to 10,000 nmol/L (r2 = 0.999). Within-batch and between-batch imprecision was <10% and bias <15% at 3 concentrations, the limit of detection was 5 nmol/L and lower limit of quantitation 15 nmol/L. No interference was observed with l-tryptophan or 5-hydroxytryptamine. Comparison of LC–MS/MS and HPLC showed good agreement between the two methods but this LC–MS/MS assay displays several advantages; it requires 10-fold less sample, has a simpler extraction procedure and extended linearity, thus increasing laboratory throughput, lowering reagent costs and removing the need to dilute samples in patients with established carcinoid disease being monitored for therapeutic efficacy.  相似文献   

9.
A highly sensitive and selective LC–MS/MS method was developed and validated for the determination of dauricine in human plasma, using protopine as internal standard (IS). The analyte and IS were extracted by liquid–liquid extraction and analyzed by LC–MS/MS. Chromatographic separation was performed on Agilent TC-C18 column with a mobile phase of methanol–water–glacial acetic acid (60:40:0.8, v/v/v) at a flow rate of 0.7 mL/min. Detection was performed on a triple quadrupole tandem mass spectrum by multiple reaction monitoring (MRM) mode using the electrospray ionization technique in positive mode. The method was linear over the concentration range of 1–200 ng/mL. The lower limit of quantification (LLOQ) was 1 ng/mL in human plasma with acceptable precision and accuracy. The intra- and inter-day precision was less than 5.9% determined from quality control (QC) samples at concentrations of 2.0, 20.0 and 160 ng/mL, and the accuracy was within ±9.9%. This method was successfully applied for the evaluation of pharmacokinetics of dauricine after oral doses of 100, 300 and 600 mg phenolic alkaloids of menispermum dauricum tablet (PAMDT) to 12 Chinese healthy volunteers.  相似文献   

10.
Sirolimus and its derivative everolimus are widely used today as immunosuppressive agents for example in the transplantation medicine. The problematic pharmacokinetic behavior of those substances makes therapeutic drug monitoring mandatory. Therefore, a fast, simple and sensitive high-throughput procedure using online extraction with turbulent flow chromatography for the concurrent measurement of sirolimus and everolimus has been developed. 200 μl of whole blood was mixed with internal standard (23-desmethoxyrapamycin) and the precipitation solution and centrifuged. An aliquot of the supernatant was transferred into autosampler vials. 50 μl of the supernatant was injected into the LC system, where the analytes were extracted using turbulent flow chromatography and thereafter analyzed using reversed phase chromatography. Detection was done by atmospherical pressure chemical ionization (APCI) mass spectrometry in the negative ionization mode. The method has been fully validated and compared to a previously used method. The method was shown to be linear over the entire calibration range (2.2–43.7 μg/l for everolimus and 2.9–51.2 μg/l for sirolimus). The lower limit of quantification was 0.5 μg/l for both compounds. For within-day and between-day analysis, the CV's were <7.6% for everolimus and <8.7% for sirolimus, respectively. The accuracy was between 92.1% and 105% for everolimus and 96.1% and 106% for sirolimus. Recovery ranged between 46.3% and 50.6% for everolimus and 51.2% and 57.2% for sirolimus. The method was demonstrated to be free of matrix effects and comparable to the previously used method. The presented LC–MS/MS method, using turbulent flow chromatography online extraction, allows a fast, simple and reliable determination of everolimus and sirolimus.  相似文献   

11.
A rapid, selective and sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of cefuroxime in human plasma. Cefuroxime and the internal standard (IS), cefoxitin, were extracted from plasma samples using solid phase extraction with Oasis HLB cartridges. Chromatographic separation was performed on a LiChrospher® 60 RP Select B column (125 mm × 4 mm i.d., 5 μm particle size) using acetonitrile:5 ± 0.2 mM ammonium acetate solution:glacial acetic acid (70:30:0.020, v/v/v) as the mobile phase at a flow rate of 0.8 mL/min. Detection of cefuroxime and cefoxitin was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in negative ion mode. The calibration curves were linear over the range of 81.0–15976.2 ng/mL with the lower limit of quantitation validated at 81.0 ng/mL. The intra- and inter-day precisions were within 7.6%, while the accuracy was within ±6.3% of nominal values. No matrix effect was observed in this method. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic and bioequivalence parameters of cefuroxime after an oral administration of 500 mg cefuroxime tablet to 36 healthy male volunteers.  相似文献   

12.
Melatonin is a hormone mainly involved in the regulation of circadian and seasonal rhythms in both invertebrates and vertebrates. Despite the identification of melatonin in many insects, its involvement in the insect seasonal response remains unclear. A liquid chromatography tandem mass spectrometry (LC–MS/MS) method has been developed for melatonin analysis in aphids (Acyrthosiphon pisum) for the first time. After comparing two different procedures and five extraction solvents, a sample preparation procedure with a mixture of methanol/water (50:50) was selected for melatonin extraction. The method was validated by analyzing melatonin recovery at three spiked concentrations (5, 50 and 100 pg/mg) and showed satisfactory recoveries (75–110%), and good repeatability, expressed as relative standard deviation (<10%). Limits of detection (LOD) and quantitation (LOQ) were 1 pg/mg and 5 pg/mg, respectively. Eight concentration levels were used for constructing the calibration curves which showed good linearity between LOQ and 200 times LOQ. The validated method was successfully applied to 26 aphid samples demonstrating its usefulness for melatonin determination in insects. This is -to our knowledge- the first identification of melatonin in aphids by LC–MS/MS.  相似文献   

13.
Enzyme immunoassays (EIA) are commonly utilized for the evaluation of androgens in biological fluids; however, careful consideration must be given to cross-reactivity with other endogenous sex-steroid hormones. Our purpose was to determine the validity of a commonly-utilized commercially-available dihydrotestosterone (DHT) EIA. Serum samples obtained from older hypogonadal men who participated in a 12-month randomized controlled trial evaluating the effects of testosterone-enanthate (125 mg/week) or vehicle in combination with finasteride (5 mg/day) or placebo were assayed for DHT via EIA and using a validated gold-standard LC–MS/MS approach. Additionally, commercially-available (DHT-free) buffer containing graded testosterone doses was evaluated by DHT immunoassay. DHT concentrations measured via EIA were 79% to >1000% higher than values obtained by LC–MS/MS (p < 0.05), with the largest differences (415–1128%) occuring in groups receiving finasteride. Both LC–MS/MS and EIA indicated that testosterone-enanthate increased serum DHT to a similar magnitude. In contrast, finasteride-induced reductions in DHT were detected by LC–MS/MS, but not EIA (p < 0.05). No significant associations were present for DHT concentrations between measurement techniques. Cross-reactivity of testosterone with the immunoassay ranged from 18% to 99% and DHT concentrations measured by EIA were highly associated with the spiked testosterone concentrations in DHT-free buffer (r = 0.885, p < 0.001). In conclusion, we provide evidence invalidating a commonly-utilized commercially-available DHT immunoassay because significant cross-reactivity exists between testosterone and the EIA and because the changes in DHT observed via EIA were not associated with a validated gold-standard measurement technique. The cross-reactivity of testosterone is particularly concerning because testsoterone is present in 100-fold greater concentrations than is DHT within the circulation.  相似文献   

14.
A rapid 2 min liquid chromatography–tandem mass spectrometry (LC–MS/MS) method operating in multiple reaction ion monitoring mode was developed and validated that allows for the characterization and simultaneous quantification of 11 phytoestrogen metabolites with mass transitions m/z 241/119 (equol), 253/132 (daidzein), 255/149 (dihydrodaidzein), 257/108 (O-desmethylangolesin), 269/133 (genistein), 283/184 (glycitein), 267/191 (formononetin), 289/109 (biochanin A), 267/91 (coumestrol), enterodiol (301/253), and enterolactone (297/253). The method was demonstrated to be specific and sensitive, and a linear response for each phytoestrogen was observed over a range of 1–5000 ng/mL in human serum with the exception of dihydrodaidzein, whose lower limit of quantification was 2 ng/mL. The separation was carried out on a Synergi Polar-RP 2.5 micron (50 mm × 2.0 mm i.d.) column at 50 °C with water and acetonitrile (both containing 10 mM ammonium acetate) as the mobile phase under gradient conditions at a flow rate of 0.75 mL/min. This LC–MS/MS method is very useful for high-throughput analysis of phytoestrogens and proved to be simple, sensitive, reproducible, and reliable.  相似文献   

15.
A sensitive, precise and accurate quantitative liquid chromatography/tandem mass spectrometry (LC–MS/MS) method for the measurement of sunitinib (SU11248) and N-desethyl sunitinib (SU12662) in human plasma was developed and validated. All sample handling was done under strict light protection. The sample preparation method employed acetonitrile protein precipitation using d5-SU11248 as an internal standard. The processed samples were chromatographed on a polymeric reversed-phase analytical column and analyzed by triple-quadrupole MS/MS in multiple reaction monitoring (MRM) mode using positive TurboIonSpray® (TISP). The LC–MS/MS method described in this paper presents high absolute recovery (86.2% SU11248, 84.8% SU12662), high sensitivity (lower limit of quantitation of 0.06 ng/mL for both analytes), high inter-day precision (1.6–6.1% SU11248, 1.1–5.3% SU12662) and high analytical recovery (99.8–109.1% SU11248, 99.9–106.2% SU12662), as well as excellent linearity over the concentration range 0.060–100 ng/mL (r2 > 0.999) with a short runtime of only 4.0 min. Results on the stability of SU11248 and SU12662 in human plasma are presented. During validation plasma from intensive care patients receiving many drugs were tested for interference and incurred samples were analyzed. The method met all criteria of the EMA and FDA guidelines during validation and was successfully applied to a pharmacokinetic study in healthy human volunteers.  相似文献   

16.
Harmful algal blooms (HABs) are a natural global phenomena emerging in severity and extent. Incidents have many economic, ecological and human health impacts. Monitoring and providing early warning of toxic HABs are critical for protecting public health. Current monitoring programmes include measuring the number of toxic phytoplankton cells in the water and biotoxin levels in shellfish tissue. As these efforts are demanding and labour intensive, methods which improve the efficiency are essential. This study compares the utilisation of a multitoxin surface plasmon resonance (multitoxin SPR) biosensor with enzyme-linked immunosorbent assay (ELISA) and analytical methods such as high performance liquid chromatography with fluorescence detection (HPLC-FLD) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) for toxic HAB monitoring efforts in Europe. Seawater samples (n = 256) from European waters, collected 2009–2011, were analysed for biotoxins: saxitoxin and analogues, okadaic acid and dinophysistoxins 1/2 (DTX1/DTX2) and domoic acid responsible for paralytic shellfish poisoning (PSP), diarrheic shellfish poisoning (DSP) and amnesic shellfish poisoning (ASP), respectively. Biotoxins were detected mainly in samples from Spain and Ireland. France and Norway appeared to have the lowest number of toxic samples. Both the multitoxin SPR biosensor and the RNA microarray were more sensitive at detecting toxic HABs than standard light microscopy phytoplankton monitoring. Correlations between each of the detection methods were performed with the overall agreement, based on statistical 2 × 2 comparison tables, between each testing platform ranging between 32% and 74% for all three toxin families illustrating that one individual testing method may not be an ideal solution. An efficient early warning monitoring system for the detection of toxic HABs could therefore be achieved by combining both the multitoxin SPR biosensor and RNA microarray.  相似文献   

17.
BackgroundThe accurate measurement of 25-hydoxy vitamin D (25OH-D) in serum has been a challenge for many years. We developed a liquid chromatography tandem mass spectrometry (LC Tandem MS) assay for the quantitative determination of 25OH-D2 and 25OH-D3 in serum. The new method was compared with two widely used commercially available immunoassays.MethodsSample preparation involved protein precipitation with acetonitrile containing deuterated forms of the target species as internal standards. An API 5000 mass spectrometer coupled with a photoionization source was used for quantitation. The performance of the new LC Tandem MS assay was compared with a radioimmunoassay (RIA, Diasorin) and a chemiluminescence immunoassay (ECLIA, Roche Diagnostics), analysing serum obtained from 152 individuals.ResultsUsing 100 μl of serum, the LC Tandem MS assay had a limit of quantitation of 1.3 nmol/L for both 25OH-D2 and 25OH-D3 with a linear response between 1.3 and 625 nmol/L and accuracy of between 95 and 124%. Intra- and inter-assay precision were ≤7% and ≤4%, respectively. Measurement of 25OH-D levels in 152 serum samples gave run averages of 71, 56 and 62 nmol/L for LC Tandem MS, ECLIA and RIA, respectively. Correlations between the various methods were: LC Tandem MS vs. RIA: r = 0.931; LC Tandem MS vs. ECLIA: r = 0.784; RIA vs. ECLIA: r = 0.787. The LC Tandem MS method had a positive proportional bias of 26% over the RIA, whereas the ECLIA showed variable differences.ConclusionThe new LC Tandem MS assay is accurate and precise at physiologically relevant 25OH-D concentrations, and compares favourably with the RIA. In contrast, the ECLIA shows variable bias with the other assays tested.  相似文献   

18.
A rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of picamilon concentration in human plasma. Picamilon was extracted from human plasma by protein precipitation. High performance liquid chromatography separation was performed on a Venusil ASB C18 column with a mobile phase consisting of methanol ?10 mM ammonium acetate–formic acid (55:45:01, v/v/v) at a flow rate of 0.65 ml/min. Acquisition of mass spectrometric data was performed in selected reaction monitoring mode, using the transitions of m/z 209.0  m/z (78.0 + 106.0) for picamilon and m/z 152.0  m/z (93.0 + 110.0) for paracetamol (internal standard). The method was linear in the concentration range of 1.00–5000 ng/ml for the analyte. The lower limit of quantification was 1.00 ng/ml. The intra- and inter-assay precision were below 13.5%, and the accuracy was between 99.6% and 101.6%. The method was successfully applied to characterize the pharmacokinetic profiles of picamilon in healthy volunteers. This validated LC–MS/MS method was selective and rapid, and is suitable for the pharmacokinetic study of picamilon in humans.  相似文献   

19.
A method for Selenocystine and Selenomethionine determination by LC–ES–MS was developed in this work. The mass spectrometer was used in a positive mode and the m/z used for the identification of Selenomethionine and Selenocystine were 198.35 and 337.15, respectively.The selenium species were separated using a LC system. A silica chromatographic column (ZORBAX Eclipse XDB-C8 of 50 mm length and 2.1 mm internal diameter (particle size 3.5 μm)) was used. The separation was realised in isocratic mode, using methanol:water (1:1) with 1% of acetic acid and a flow rate of 200 μL min−1. The developed method was precise (RSD of 4.5% and 3.9% for Selenomethionine and Selenocystine, respectively) and sensible (limit of detection (LOD) 0.06 and 0.99 mg L−1 for selenomethionine and selenocystine, respectively).  相似文献   

20.
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the simultaneous determination of eight β-lactam antibiotics, including ampicillin, cefazolin, cefepime, cefmetazole, cefotaxime, doripenem, meropenem, and piperacillin, in human serum. Sample specimens were subjected to solid phase extraction (SPE) using Waters Oasis® HLB cartridges (30 mg). Chromatographic separation was performed with a high-resolution octadecyl silica column compatible with hydrophilic compounds, using a gradient of 10 mM aqueous ammonium formate containing 0.1% formic acid-methanol. Antibiotics were detected by a triple quadrupole mass spectrometer (MS/MS) with electrospray ionization and quantified by the multiple reaction monitoring mode. A total run time of 13 min was applied. Linearity in the calibration was obtained over a range of 0.1–50 μg/mL of the β-lactam antibiotics, except for doripenem. The lower limit of quantification was 0.005–0.5 μg/mL, using 50 μL serum. The recovery rate exceeded 80.2% for these analytes, except for doripenem (49.1%) and meropenem (62.3%). The present method is applicable to routine therapeutic monitoring of β-lactam antibiotics in clinical practice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏