首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Quantitative analysis of two opioid peptides, DSLET [(d-Ser2)Leu-enkephalin-Thr6] and Met-enkephalin-Arg-Gly-Leu, was performed using microbore liquid chromatography interfaced to electrospray ionization tandem mass spectrometry. Validation of the methodology was demonstrated for each peptide in plasma. Quantitative analyses were performed through the use of a deuterium labelled peptide analog as an internal standard. Linearity was observed for the analysis of DSLET (5–1000 ng/ml) and Met-enkephalin-Arg-Gly-Leu (1–1000 ng/ml) in plasma with a limit of detection of 0.25 ng/ml for Met-enkephalin-Arg-Gly-Leu and 1.0 ng/ml for DSLET. In general, the observed concentrations showed good reproducibility with coefficients of variation of within 15%. In the concentration range studied, only 0.5 ml of plasma was required for optimal detection of Met-enkephalin-Arg-Gly-Leu and 0.25 ml for DSLET. Application of this method was demonstrated by studying the disposition of DSLET in a rat. DSLET administered to a rat exhibited a short half-life and a high clearance value.  相似文献   

2.
A sensitive and specific assay of imidapril and its active metabolite, imidaprilat, in human plasma has been developed. This method is based on rapid isolation and high-performance liquid chromatography (HPLC)–electrospray ionization (ESI)-tandem mass spectrometry (MS–MS). Imidapril and imidaprilat were isolated from human plasma using OASIS HLB (solid-phase extraction cartridge), after deproteinization. The eluent from the cartridge was evaporated to dryness, and the residue was reconstituted in mobile phase and injected into the HPLC–ESI-MS–MS system. Each compound was separated on a semi-micro ODS column in acetonitrile–0.05% (v/v) formic acid (1:3, v/v). The selected ion monitoring using precursor→product ion combinations of m/z 406→234 and 378→206, was used for determination of imidapril and imidaprilat, respectively. The linearity was confirmed in the concentration range of 0.2 to 50 ng/ml in human plasma, and the precision of this assay, expressed as a relative standard deviation, was less than 13.2% over the entire concentration range with adequate assay accuracy. The HPLC–ESI-MS–MS method correlates well with the radioimmunoassay method, therefore, it is useful for the determination of imidapril and imidaprilat with sufficient sensitivity and specificity in clinical studies.  相似文献   

3.
A wide variety of sulfur metabolites play important roles in plant functions. We have developed a precise and sensitive method for the simultaneous measurement of several sulfur metabolites based on liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) and 34S metabolic labeling of sulfur-containing metabolites in Arabidopsis thaliana seedlings. However, some sulfur metabolites were unstable during the extraction procedure. Our proposed method does not allow for the detection of the important sulfur metabolite homocysteine because of its instability during sample extraction. Stable isotope-labeled sulfur metabolites of A. thaliana shoot were extracted and utilized as internal standards for quantification of sulfur metabolites with LC–MS/MS using S-adenosylmethionine (SAM), S-adenosylhomocysteine (SAH), methionine (Met), glutathione (GSH), and glutathione disulfide (GSSG) as example metabolites. These metabolites were detected using electrospray ionization in positive mode. Standard curves were linear (r2 > 0.99) over a range of concentrations (SAM 0.01–2.0 μM, SAH 0.002–0.10 μM, Met 0.05–4.0 μM, GSH 0.17–20.0 μM, GSSG 0.07–20.0 μM), with limits of detection for SAM, SAH, Met, GSH, and GSSG of 0.83, 0.67, 10, 0.56, and 1.1 nM, respectively; and the within-run and between-run coefficients of variation based on quality control samples were less than 8%.  相似文献   

4.
The drug combination rifampicin and clarithromycin is used in regimens for infections caused by Mycobacteria. Rifampicin is a CYP3A4 inducer while clarithromycin is known to inhibit CYP3A4. During combined therapy rifampicin concentrations may increase and clarithromycin concentrations may decrease. Therefore a simple, rapid and easy method for the measurement of the blood concentrations of these drugs and their main metabolites (14-hydroxyclarithromycin and 25-desacetylrifampicin) is developed to evaluate the effect of the drug interaction. The method is based on the precipitation of proteins in human serum with precipitation reagent containing the internal standard (cyanoimipramine) and subsequently high-performance liquid chromatography (HPLC) analysis and tandem mass spectrometry (MS/MS) detection in an electron positive mode. The method validation included selectivity, linearity, accuracy, precision, dilution integrity, recovery and stability according to the “Guidance for Industry – Bioanalytical Method Validation” of the FDA. The calibration curves were linear in the range of 0.10–10.0 mg/L for clarithromycin and 14-hydroxyclarithromycin and 0.20–5.0 mg/L for rifampicin and 25-desacetylrifampicin, with within-run and between-run precisions (CVs) in the range of 0% to ?10%. The components in human plasma are stable after freeze–thaw (three cycles), in the autosampler (3 days), in the refrigerator (3 days) and at room temperature (clarithromycin and 14-hydroxyclarithromycin: 3 days; rifampicin and 25-desacetylrifampicin: 1 day). The developed rapid and fully validated liquid chromatography–tandem mass spectrometry (LC/MS/MS) method is suitable for the determination of clarithromycin, 14-hydroxyclarithromycin, rifampicin and 25-desacetylrifampicin in human plasma.  相似文献   

5.
In this paper, a method for the sensitive and reproducible analysis of lignocaine and its four principal metabolites, monoethylxylidide (MEGX), glycylxylidide (GX), 3-hydroxylignocaine (3-HO-LIG), 4-hydroxylignocaine (4-HO-LIG) in equine urine and plasma samples is presented. The method uses liquid chromatography coupled to tandem mass spectrometry operating in electrospray ionisation positive ion mode (+ESI) via multiple reaction monitoring (MRM). Sample preparation involved solid-phase extraction using a mixed-mode phase. The internal standard adopted was lignocaine-d10. Lignocaine and its metabolites were successfully resolved using an octadecylsilica reversed-phase column using a gradient mobile phase of acetonitrile and 0.1% (v/v) aqueous formic acid at a flow rate of 300 μL/min. Target analytes and the internal standard were determined by using the following transitions; lignocaine, 235.2 > 86.1; 3-HO-LIG and 4-HO-LIG, 251.2 > 86.1; MEGX, 207.1 > 58.1; GX, 179.1 > 122.1; and lignocaine-d10, 245.2 > 96.1. Calibration curves were generated over the range 1–100 ng/mL for plasma samples and 1–1000 ng/mL for urine samples. The method was validated for instrument linearity, repeatability and detection limit (IDL), method linearity, repeatability, detection limit (MDL), quantitation limit (LOQ) and recovery. The method was successfully used to analyse both plasma and urine samples following a subcutaneous administration of lignocaine to a thoroughbred horse.  相似文献   

6.
A rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method was developed and validated for determination of cymipristone in human plasma. Mifepristone was used as the internal standard (IS). Plasma samples were deproteinized using methanol. The compounds were separated on a ZORBAX SB C18 column (50 mm × 2.1 mm i.d., dp 1.8 μm) with gradient elution at a flow-rate of 0.3 ml/min. The mobile phase consisted of 10 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring (SRM) mode via electrospray ionization. Target ions were monitored at [M+H]+ m/z 498  416 and 430  372 in positive electrospray ionization (ESI) mode for cymipristone and IS, respectively. Linearity was established for the range of concentrations 0.5–100 ng/ml with a coefficient correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.5 ng/ml. The validated method was successfully applied to study the pharmacokinetics of cymipristone in healthy Chinese female subjects.  相似文献   

7.
A simple and sensitive method is proposed for the determination of seven low-molecular mass aldehydes in human urine samples using liquid chromatography with tandem mass spectrometric detection. Urine samples diluted twofold with 0.3 M hydrochloric acid are aspirated into a LiChrolut EN solid-phase extraction column impregnated with 2,4-dinitrophenylhydrazine for cleanup, derivatization and preconcentration of the aldehydes. After elution of the hydrazones with acetonitrile, an aliquot is injected directly into the chromatograph. Identification and quantification of aldehydes was performed with electrospray in negative ion mode by selected reaction monitoring. By using synthetic urine samples, linearity is established over the concentration range 0.1–30 μg/l and limits of detection from 15 to 65 ng/l. The intra- and inter-day precision (RSD, %) of the aldehydes ranged from 2.9% to 6.4% and 3.6% to 9.3%, respectively, and specific uncertainties were ca. 5.0 ± 0.3 ng for all aldehydes. Average recoveries performed on two levels by enriching synthetic urine samples ranged between 92% and 100%. The method was also validated in terms of study sample stability including long-term and short-term analyte stability, freeze–thaw and extract stability. In summary, the method proposed surpasses other recent chromatographic alternatives in terms of the limit of detection and sample requirements for analysis.  相似文献   

8.
An improved method of detection of the isoflavone aglycones, genistein and daidzein, is reported using solid-phase microextraction–high-performance liquid chromatography–electrospray ionization mass spectrometry (SPME–HPLC–ESI-MS). Extraction of the isoflavonoids from urine using SPME with a Carbowax–templated resin fiber coating allows rapid preconcentration of the analytes without the usual sample preparation required by other methods. Detection of the analytes is accomplished by HPLC–ESI-MS. Analysis of spiked samples of urine resulted in a linear range of 0.25 to 250 ng/ml for daidzein and 0.27 to 27.0 ng/ml for genistein. Limits of detection of daidzein and genistein were measured at 25.4 pg/ml for daidzein and 2.70 pg/ml for genistein. Daidzein and genistein were detected in urine following consumption of a soy drink.  相似文献   

9.
A rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of picamilon concentration in human plasma. Picamilon was extracted from human plasma by protein precipitation. High performance liquid chromatography separation was performed on a Venusil ASB C18 column with a mobile phase consisting of methanol ?10 mM ammonium acetate–formic acid (55:45:01, v/v/v) at a flow rate of 0.65 ml/min. Acquisition of mass spectrometric data was performed in selected reaction monitoring mode, using the transitions of m/z 209.0  m/z (78.0 + 106.0) for picamilon and m/z 152.0  m/z (93.0 + 110.0) for paracetamol (internal standard). The method was linear in the concentration range of 1.00–5000 ng/ml for the analyte. The lower limit of quantification was 1.00 ng/ml. The intra- and inter-assay precision were below 13.5%, and the accuracy was between 99.6% and 101.6%. The method was successfully applied to characterize the pharmacokinetic profiles of picamilon in healthy volunteers. This validated LC–MS/MS method was selective and rapid, and is suitable for the pharmacokinetic study of picamilon in humans.  相似文献   

10.
We report a sensitive and robust method to determine cholic acid (CA), chenodeoxycholic acid (CDCA), deoxycholic acid (DCA), lithocholic acid (LCA), ursodeoxycholic acid (UDCA), and their taurine- and glycine-conjugate concentrations in human plasma using liquid chromatography–tandem mass spectrometry. Activated charcoal was utilized to prepare bile acid-free plasma, which served as the biological matrix for the preparation of standard and quality control samples. Plasma sample preparation involved solid-phase extraction. A total of 16 bile acids and 5 internal standards were separated on a reverse column by gradient elution and detected by tandem mass spectrometry in negative ion mode. The calibration curve was linear for all the bile acids over a range of 0.005–5 μmol/L. The extraction recoveries for all the analytes fell in the range of 88–101%. Intra-day and inter-day coefficients of variation were all below 10%. A stability test showed that all the bile acids were stable in plasma for at least 6 h at room temperature, at least three freeze–thaw cycles, in the −70 °C or −20 °C freezer for 2 months, and also in the reconstitution solution at 8 °C for 48 h. Comparison of the matrix effect of bile acid-free plasma with that of real plasma indicated that the charcoal purification procedure did not affect the properties of charcoal-purified plasma as calibration matrix. This method has been used to determine the bile acid concentrations in more than 300 plasma samples from healthy individuals. In conclusion, this method is suitable for the simultaneous quantification of individual bile acids in human plasma.  相似文献   

11.
Here we report a method capable of quantifying ginsenoside Rg3 in human plasma and urine. The method was validated over linear range of 2.5–1000.0 ng mL−1 for plasma and 2.0–20.0 ng mL−1 for urine using ginsenoside Rg1 as I.S. Compounds were extracted with ethyl acetate and analyzed by HPLC/MS/MS (API-4000 system equipped with ESI interface and a C18 column). The inter- and intra-day precision and accuracy of QC samples were ≤8.5% relative error and were ≤14.4% relative standard deviation for plasma; were ≤5.6% and ≤13.3% for urine. The Rg3 was stable after 24 h at room temperature, 3 freeze/thaw cycles and 131 days at −30 °C. This method has been applied to pharmacokinetic study of ginsenoside Rg3 in human.  相似文献   

12.
Two methods based on solid-phase extraction (SPE) using traditional cartridges and microelution SPE plates (μSPE) as the sample pre-treatment, and an improved liquid chromatography coupled to tandem mass spectrometry (UPLC–MS/MS) were developed and compared to determine the phenolic compounds in virgin oil olive from plasma samples. The phenolic compounds studied were hydroxytyrosol, tyrosol, homovanillic acid, p-coumaric acid, 3,4-DHPEA-EDA, p-HPEA-EDA, luteolin, apigenin, pinoresinol and acetoxypinoresinol. Good recoveries were obtained in both methods, and the LOQs and LODs were similar, in the range of low μM. The advantage of μSPE, in comparison with SPE cartridges, was the lack of the evaporation step to pre-concentrate the analytes. The μSPE-UPLC–ESI-MS/MS method developed was then applied to determine the phenolic compounds and their metabolites, in glucuronide, sulphate and methylated forms, in human plasma after the ingestion of virgin olive oil.  相似文献   

13.
We present an assay which employs enzyme digestion and solid phase extraction followed by liquid chromatography–tandem mass spectrometry to simultaneously quantify 16 hydroxylated polycyclic aromatic hydrocarbons (OHPAHs) in 3-ml samples of urine. The analytes consisted of 2-, 3-, and 4-ring OHPAHs, namely, 1- and 2-hydroxynaphthalene (1- and 2-OHNAP), 2-hydroxyfluorine (2-OHFLU), 1-, 2-, 3-, 4-, and 9-hydroxyphenanthrene (1-, 2-, 3-, 4-, and 9-OHPHE), 1-hydroxypyrene (1-OHPYR), 1- and 2-hydroxybenzo(a)anthracene (1- and 2-OHBAA), 3- and 6-hydroxychrysene (3- and 6-OHCHR) and 3-, 7-, and 9-hydroxybenzo(a)pyrene (3-, 7-, and 9-OHBAP). The method was validated using urine samples from steel workers and control subjects. The coefficients of variation of the method for the particular analytes were between 7% and 27% and the limits of quantitation were between 0.002 and 0.010 μg/l urine. The 2- and 3-ring OHPAHs were easily quantified in all subjects. However, 1-OHPYR was the only representative of the 4- and 5-ring metabolites that could be quantified. Pairwise correlations showed that all OHPAHs were highly correlated with each other (0.553  r  0.910) and with 1-OHPYR (0.614  r  0.910), the metabolite most widely accepted as a short-term biomarker of exposure to PAHs. The analyte, 2-OHNAP exhibited the lowest pairwise correlations with the other OHPAHs (0.542  r  0.628), presumably due to confounding by smoking. Metabolites of phenanthrene, an abundant PAH and the smallest to possess a bay region, are promising OHPAHs for characterizing both exposures to PAHs and the various metabolic pathways.  相似文献   

14.
In order to discriminate selegiline (SG) use from methamphetamine (MA) use, the urinary metabolites of SG users have been investigated using high-performance liquid chromatography (HPLC)–electrospray ionization mass spectrometry (HPLC–ESI–MS). Selegiline-N-oxide (SGO), a specific metabolite of SG, was for the first time detected in the urine, in addition to other metabolites MA, amphetamine (AP) and desmethylselegiline (DM-SG). A combination of a Sep-pak C18 cartridge for the solid-phase extraction, a semi-micro SCX column (1.5 mm I.D.×150 mm) for HPLC separation and ESI–MS for detection provided a simple and sensitive procedure for the simultaneous determination of these analytes. Acetonitrile–10 mM ammonium formate buffer adjusted to pH 3.0 (70:30, v/v) at a flow-rate of 0.1 ml/min was found to be the most effective mobile phase. Linear calibration curves were obtained over the concentration range from 0.5 to 100 ng/ml for all the analytes by monitoring each protonated molecular ion in the selected ion monitoring (SIM) mode. The detection limits ranged from 0.1 to 0.5 ng/ml. Upon applying the scan mode, 10–20 ng/ml were the detection limits. Quantitative investigation utilizing this revealed that SGO was about three times more abundant (47 ng/ml, 79 ng/ml) than DM-SG in two SG users’ urine samples tested here. This newly-detected, specific metabolite SGO was found to be an effective indicator for SG administration.  相似文献   

15.
An enantioselective and sensitive method was developed and validated for determination of doxazosin enantiomers in human plasma by liquid chromatography–tandem mass spectrometry. The enantiomers of doxazosin were extracted from plasma using ethyl ether/dichloromethane (3/2, v/v) under alkaline conditions. Baseline chiral separation was obtained within 9 min on an ovomucoid column using an isocratic mobile phase of methanol/5 mM ammonium acetate/formic acid (20/80/0.016, v/v/v) at a flow rate of 0.60 mL/min. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, using the transitions of m/z 452 → 344 for doxazosin enantiomers, and m/z 384 → 247 for prazosin (internal standard). The method was linear in the concentration range of 0.100–50.0 ng/mL for each enantiomer using 200 μL of plasma. The lower limit of quantification (LLOQ) for each enantiomer was 0.100 ng/mL. The intra- and inter-assay precision was 5.0–11.1% and 5.7–7.6% for R-(−)-doxazosin and S-(+)-doxazosin, respectively. The accuracy was 97.4–99.5% for R-(−)-doxazosin and 96.8–102.8% for S-(+)-doxazosin. No chiral inversion was observed during the plasma storage, preparation and analysis. The method proved adequate for enantioselective pharmacokinetic studies of doxazosin after oral administration of therapeutic doses of racemic doxazosin.  相似文献   

16.
17.
A confirmation procedure is described for residues of spectinomycin in bovine milk. Spectinomycin is extracted from raw milk using ion-pair reversed-phase solid-phase extraction. The extracts are ion-pair chromatographed on a polymeric reversed-phase column and analyzed on a quadrupole ion trap mass spectrometer equipped with an electrospray interface. MS–MS data are acquired in the scan mode of product ions deriving from m/z 333, the protonated molecular ion. The estimated limit of confirmation is between 0.05 and 0.1 μg/ml. The procedure was validated with control milk, fortified milk (0.1–5.0 μg/ml), and milk from cows dosed with spectinomycin.  相似文献   

18.
The tetrapeptide AcSDKP, a natural and specific substrate of angiotensin I-converting enzyme (ACE), is a negative regulator of hematopoiesis. AcSDKP has been measured in various biological media using an enzyme immunoassay (EIA), but its presence in human plasma and urine has not been formally established. By using immunoaffinity extraction and liquid chromatography–electrospray mass spectrometry, we demonstrate that AcSDKP-like immunoreactivity measured with EIA in plasma and urine samples from untreated, captopril- (an ACE inhibitor) and AcSDKP-treated subjects corresponds to AcSDKP. The present study confirms that AcSDKP is naturally present in human plasma and urine and that EIA is reliable for its measurement in such media.  相似文献   

19.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed to determine the concentration of eptifibatide in human plasma. Following protein precipitation, the analyte was separated on a reversed-phase C18 column. Acetonitrile:5 mM ammonium acetate:acetic acid (30:70:0.1, v/v/v) was used at a flow-rate of 0.5 mL/min with the isocratic mobile phase. An API 4000 tandem mass spectrometer equipped with a Turbo IonSpray ionization source was used as the detector and was operated in the positive ion mode. “Truncated” multiple reaction monitoring using the transition of m/z 832.6  m/z 832.6 and m/z 931.3  m/z 931.3 was performed to quantify eptifibatide and the internal standard (EPM-05), respectively. The method had a lower limit of quantification of 4.61 ng/mL for eptifibatide. The calibration curve was demonstrated to be linear over the concentration range of 4.61 ? 2770 ng/mL. The intra- and inter-day precisions were less than 10.5% for each QC level, and the inter-day relative errors were 2.0%, 5.6%, and 2.8% for 9.22, 184, and 2490 ng/mL, respectively. The validated method was successfully applied to the quantification of eptifibatide concentration in human plasma after intravenous (i.v.) administration of a 270-μg/kg bolus of eptifibatide and i.v. administration of eptifibatide at a constant rate of infusion of 2 μg/(kg min) for 18 h in order to evaluate the pharmacokinetics.  相似文献   

20.
A rapid, selective and highly sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of eptifibatide in human plasma. Eptifibatide and the internal standard (IS), EPM-05, were extracted from plasma samples using solid phase extraction. Chromatographic separation was performed on a C18 column at a flow rate of 0.5 mL/min. Detection of eptifibatide and the IS was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in positive ion mode. Traditional multiple reaction monitoring (MRM) using the transition of m/z 832.6 → m/z 646.4 and m/z 931.6 → m/z 159.4 was performed to quantify eptifibatide and the IS, respectively. The calibration curves were linear over the range of 1–1000 ng/mL with the lower limit of quantitation validated at 1 ng/mL. The intra- and inter-day precisions were within 13.3%, while the accuracy was within ±7.6% of nominal values. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of eptifibatide after intravenous (i.v.) administration of a 45 μg/kg bolus of eptifibatide to 8 healthy volunteers.  相似文献   