首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive method for the separation and determination of amlodipine enantiomers in plasma has been developed based on solid-phase extraction (SPE) with disposable extraction cartridges (DECs) in combination with chiral liquid chromatography (LC). The SPE technique is used to isolate the drug from the biological matrix and to prepare a cleaner sample before injection and analysis by HPLC coupled to mass spectrometry. The DEC is filled with ethyl silica (50 mg) and is first conditioned with a 2.5% ammonia in methanol solution and then with ammonium acetate buffer. A 1.0-ml volume of plasma is then applied on the DEC. The washing step is first performed with ammonium acetate buffer and secondly with a mixture of water and methanol (65:35, v/v), while the final elution step is obtained by dispensing methanol containing 2.5% of ammonia. The eluate is then collected and evaporated to dryness before being dissolved in the LC mobile phase and injected into the LC system. The stereoselective analysis of amlodipine is achieved on a Chiral AGP column containing alpha(1)-acid glycoprotein as chiral selector by using a mobile phase consisting of a 10-mM acetate buffer (pH 4.5) and 1-propanol (99:1, v/v). The LC system is coupled to tandem mass spectrometry with an APCI interface in the positive-ion mode. The chromatographed analytes are detected in the selected reaction monitoring mode (SRM). The MS/MS ion transitions monitored are 409 to 238 for amlodipine, and 260 to 116 for S-(-)-propranolol used as internal standard (IS). The method was validated considering different parameters, such as linearity, precision and accuracy. The limit of quantitation was found to be 0.1 ng/ml for each amlodipine enantiomer.  相似文献   

2.
A sensitive and selective liquid chromatography-tandem mass spectrometry method (LC-MS-MS) for the simultaneous estimation of bulaquine and primaquine has been developed and validated in monkey plasma. The mobile phase consisted of acetonitrile/ammonium acetate buffer (20 mM, pH 6) (50:50 v/v) at a flow-rate of 1 ml/min. The chromatographic separations were achieved on two spheri cyano columns (5 microm, 30 x 4.6 mm I.D.) connected in series. The quantitation was carried out using a Micromass LC-MS-MS with an electrospray source in the multiple reaction monitoring (MRM) mode. The analytes were quantified from the summed total ion value of their two most intense molecular transitions. This is another novel method leading to increased sensitivity and precision. A simple liquid-liquid extraction with 2 x 1.0 ml n-hexane/ethyl acetate/dimethyloctyl amine (90:10:0.05, v/v) was utilized. The method was validated in terms of recovery, linearity, accuracy and precision (within- and between-assay variation). The recoveries from spiked control samples were >or=90 and 50% for bulaquine and primaquine, respectively. Linearity in plasma was observed over a dynamic range of 1.56-400 and 3.91-1000 ng/ml for bulaquine and primaquine, respectively.  相似文献   

3.
A stereoselective liquid chromatography-tandem mass spectrometry assay was developed and validated for quantification of S- and R-metoprolol at concentrations of 0.5-50 microg/L in human plasma. Metoprolol was extracted from plasma by liquid-liquid extraction with ethyl acetate (82% recovery). Chromatographic separation of the enantiomers was achieved on a chiral Chirobiotic T column using an isocratic mobile phase consisting of methanol/acetic acid/ammonia (100/0.15/0.15, v/v/v). An ion trap mass spectrometer with an electrospray interface was used for detection in the positive mode, monitoring the m/z transition 268-->191 for metoprolol. Standard curves for S- and R-metoprolol fitted quadratic functions (r(2)>or=0.9995) over the range 0.5-50 microg/L in plasma, with 0.5 microg/L representing the limit of quantification. In this range, relative standard deviations were <6% for intra-day precision and <10% for inter-day precision. The accuracy was within the range of 92-105%.  相似文献   

4.
A sensitive and specific method using a one-step liquid-liquid extraction (LLE) with ethyl acetate followed by high-performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed and validated for the determination of roxatidine in human plasma using famotidine as an internal standard (IS). Data acquisition was carried out in multiple reaction monitoring (MRM) mode, by monitoring the transitions m/z 307.3-->107.1 for roxatidine and m/z 338.4-->189.1 for famotidine. Chromatographic separation was performed on a reverse phase Hydrosphere C(18) column at 0.2 mL min(-1) using a mixture of methanol-ammonium formate buffer as mobile phase (20:80, v/v; adjusted to pH 3.9 with formic acid). The achieved lower limit of quantification (LLOQ) was 1.0 ng mL(-1) and the standard calibration curve for roxatidine was linear (r(2)=0.998) over the studied range (1-1000 ng mL(-1)) with acceptable accuracy and precision. Roxatidine was found to be stable in human plasma samples under short-, long-term storage and processing conditions. The developed method was validated and successfully applied to the bioequivalence study of roxatidine administrated as a single oral dose (75 mg as roxatidine acetate hydrochloride) to healthy female Korean volunteers.  相似文献   

5.
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine.  相似文献   

6.
A sensitive and high‐throughput chiral liquid chromatography–tandem mass spectrometry method was developed and validated for the quantification of R‐pantoprazole and S‐pantoprazole in human plasma. Sample extraction was carried out by using ethyl acetate liquid–liquid extraction in 96‐well plate format. The separation of pantoprazole enantiomers was performed on a CHIRALCEL OJ‐RH column and an overlapping injection mode was used to achieve a run time of 5.0 min/sample. The mobile phase consisted of 1) 10 mM ammonium acetate in methanol: acetonitrile (1:1, v/v) and 2) 20 mM ammonium acetate in water. Isocratic elution was used with flow rate at 500 μL/min. The enantiomers were quantified on a triple‐quadrupole mass spectrometer under multiple reaction monitoring (MRM) mode with m/z 382.1/230.0 for pantoprazole and m/z 388.4/230.1 for pantoprazole‐d7. Linearity from 20.0 to 5000 ng/mL was established for each enantiomer (r2 > 0.99). Extraction recovery ranged from 91.7% to 96.4% for R‐pantoprazole and from 92.5% to 96.5% for S‐pantoprazole and the IS‐normalized matrix factor was 0.98 to 1.07 for R‐pantoprazole and S‐pantoprazole, respectively. The method was demonstrated with acceptable accuracy, precision, selectivity, and stability and the method was applied to support a pharmacokinetic study of a phase I clinical trial of racemic pantoprazole in healthy Chinese subjects. Chirality 28:569–575, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

7.
A simple, rapid and accurate liquid chromatography–electrospray ionization-tandem mass spectrometry method was developed and validated for quantification of dihydroartemisinin (DHA) in human plasma. Following a simple single-step liquid–liquid extraction with ethyl acetate, the analyte was separated on a C18 column by isocratic elution with methanol–water–10 mM ammonium acetate (80:10:10, v/v/v), and analyzed by mass spectrometry in the positive ion MRM mode. Good linearity was achieved over a wide range of 1.01–2020 ng/mL. Intra- and inter-day precisions were less than 9.0%, and accuracy ranged from 93.0 to 98.2%. The pharmacokinetics of DHA injectable powder was studied for the first time in healthy subjects by this method. After single intravenous infusion of DHA injectable powder 40, 80 and 160 mg, the elimination half-life (t1/2λZ) was 1.69, 1.88 and 1.92 h, respectively; mean Cmax and AUC increased in proportion to the doses. The pharmacokinetics of DHA fit the linear dynamic feature over the DHA dose range studied.  相似文献   

8.
Solvent extraction of 6-keto-PGF1 alpha from aqueous solutions with ethyl acetate was found to result in variable and irreproducible elution patterns, when the extracts were subjected to high pressure liquid chromatography. These problems could not be resolved satisfactorily by using ethyl acetate from different suppliers, nor by changing acids or pH for acidification. After a number of unsuccessful attempts to resolve this problem, we found that variable and irreproducible elution patterns could be avoided by using methyl t-butyl ether as extraction solvent.  相似文献   

9.
A sensitive, specific and high throughput bioanalytical method using automated sample processing via 96-well plate liquid-liquid extraction and ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) has been developed for the determination of methoxsalen in human plasma. Plasma samples with ketoconazole as internal standard (IS) were prepared by employing 0.2mL human plasma in ethyl acetate:dichloromethane (80:20, v/v). The chromatographic separation was achieved on a Waters Acquity UPLC BEH C18 column using isocratic mobile phase, consisting of 10mM ammonium formate and acetonitrile (60:40, v/v), at a flow rate of 0.5mL/min. The linear dynamic range was established over the concentration range 1.1-213.1ng/mL for methoxsalen. The method was rugged and rapid with a total run time of 1.5min. It was successfully applied to a pivotal bioequivalence study in 12 healthy human subjects after oral administration of 10mg extended release methoxsalen formulation under fasting condition.  相似文献   

10.
A method to determine sildenafil in human plasma involving liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed. Sildenafil and the internal standard (I.S.), diazepam, are extracted from human plasma with ether-dichloromethane (3:2, v/v) at basic pH and analyzed by reversed-phase high-performance liquid chromatography (HPLC) using methanol-10mM ammonium acetate pH 7.0 (85:15, v/v) as the mobile phase. Detection by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring mode was linear over the concentration range 0.125-40.0 ng/ml. Intra- and inter-day precision of the assay at four concentrations within this range were 2.5-8.0%. The method was used to evaluate plasma concentration-time profiles in healthy volunteers given an oral dose of 20mg sildenafil as a combination tablet also containing apomorphine.  相似文献   

11.
A sensitive and rapid method was developed and validated for the quantitative analysis of the novel anticancer agent SZ-685C in rat plasma using high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in negative ion mode in order to support the following pre-clinical and clinical studies. SZ-685C and the internal standard (IS, emodin) were extracted from rat plasma by a simple liquid-liquid extraction technique using ethyl acetate as extraction solvent. Chromatographic separation was performed on an Elite Hypersil BDS C18 column (100 mm × 2.1 mm i.d., 3 μm). Elution was carried out using methanol/acetonitrile/2mM ammonium formate (pH 4) (80:15:5 (v/v/v)) at a flow-rate of 0.3 mL/min with a run time of 2.5 min. This assay was linear over a concentration range of 50-10,000 ng/mL with a lower limit of quantification of 50 ng/mL. The intra- and inter-batch precision was less than 15% for all quality control samples at concentrations of 100, 1000 and 7500 ng/mL. These results indicate that the method was efficient with a short run time and acceptable accuracy, precision and sensitivity. This method was successfully applied to explore pharmacokinetics of SZ-685C in rats after oral and intravenous administration of this agent. The absolute bioavailability is about 54.8-66.8% and the t(1/2) is 5.7-9.2h, these results provide basic information for further comprehensive pre-clinical research.  相似文献   

12.
A reliable analytical method was developed for the quantification and identification of muscimol (MUS) and ibotenic acid (IBO), the toxic constituents of Amanita muscaria and Amanita pantherina. MUS and IBO were extracted from mushrooms by aqueous methanol and derivatized with dansyl chloride (DNS-Cl). After extraction with ethyl acetate and evaporation of the solvent, the residue was ethylated with 1.25 M hydrogen chloride in ethanol. The resulting derivatives were quantified by high-performance liquid chromatography with UV detection and identified by liquid chromatography electrospray ionization tandem mass spectrometry. Calibration curves were linear in the range of 25-2500 ppm for MUS and 40-2500 ppm for IBO, respectively. This method was successfully applied to identify and quantify MUS and IBO in Amanita mushrooms naturally grown and circulated in the drug market.  相似文献   

13.
Analytical methods for the determination of ximelagatran, an oral direct thrombin inhibitor, its active metabolite melagatran, and intermediate metabolites, melagatran hydroxyamidine and melagatran ethyl ester, in biological samples by liquid chromatography (LC) positive electrospray ionization mass spectrometry (MS) using selected reaction monitoring are described. Isolation from human plasma was achieved by solid-phase extraction on octylsilica. Analytes and isotope-labelled internal standards were separated by LC utilising a C(18) analytical column and a mobile phase comprising acetonitrile-4 mmol/l ammonium acetate (35:65, v/v) containing 0.1% formic acid, at a flow-rate of 0.75 ml/min. Absolute recovery was approximately 80% for ximelagatran, approximately 60% for melagatran ethyl ester and >90% for melagatran and melagatran hydroxyamidine. Limit of quantification was 10 nmol/l, with a relative standard deviation <20% for each analyte and <5% above 100 nmol/l. Procedures for determination of these analytes in human urine and breast milk, plus whole blood from rat and mouse are also described.  相似文献   

14.
A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-fluorouracil in monkey serum. A liquid/liquid extraction with ethyl acetate (90%) and isopropyl alcohol (10%) was used to extract simultaneously doxifluridine and 5-FU which have considerable difference in the polarity. Optimum chromatographic separation was achieved on a Agilent Zorbax C(18) (100 mm x 2.1mm, 3.5 microm) column with a mobile phase of methanol-water (20:80, v/v). The flow rate was 0.2 mL/min with total cycle time of 5 min. The lower limit of quantification (LLOQ) was validated at 10.0 ng/mL of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both compounds met FDA Guidance criteria of +/-15% with average QC accuracy of 95.5-105.0% and coefficients of variation of 1.1-9.5% in the 10-2000 ng/mL concentration range. This method demonstrated adequate sensitivity, specificity, accuracy, precision, stability to support the analysis of monkey serum samples.  相似文献   

15.
A rapid and sensitive method using liquid chromatography–tandem mass spectrometry (LC–MS/MS) for simultaneous determination of doxazosin and verapamil in human serum has been developed. Trimipramine-d3 as an isotopic labelled internal standard was used for quantification. Serum samples were prepared by simple liquid–liquid extraction with mixture of tert butyl methyl ether and ethyl acetate (1:1, v:v). The analytes and internal standard were separated on C18 column using an isocratic elution with 5 mM ammonium formate with 0.02% formic acid and 0.02% formic acid in acetonitrile (55:45, v:v) at a flow rate of 1.1 mL/min. Positive TurboIonSpray mass spectrometry was used with multiple reaction monitoring of the transitions at: m/z 455.3 → 165.2 and 150.2 for verapamil, m/z 452.2 → 344.4 and 247.4 for doxazosin, m/z 298.2 → 103.1 for trimipramine-d3. Linearity was achieved between 1 and 500 ng/mL (R2 ≥ 0.997) for both analytes. An extensive pre-study method validation was carried out in accordance with FDA guidelines. This assay was successfully applied to determine the serum concentrations of doxazosin and verapamil in suspect non-compliance patients.  相似文献   

16.
A sensitive and specific liquid chromatography-tandem mass spectrometry assay was developed to quantify the first selective aldosterone blocker Eplerenone (I) and its hydrolyzed metabolite (II) in human plasma. The analytes (I, II) and their stable isotope-labeled analogues as internal standards were extracted on a C(18) solid-phase extraction cartridge using a Zymark RapidTrace automation system. The chromatographic separation was carried out on a narrow-bore reversed-phase Zorbax XDB-C(8) HPLC column with a mobile phase of acetonitrile/water (40:60, v/v) containing 10 mM ammonium acetate (pH 7.4). The analytes were ionized using negative-to-positive switch electrospray mass spectrometry, then detected by multiple reaction monitoring with a tandem mass spectrometer. The precursor to product ion transitions of m/z 415-->163 and m/z 431-->337 was used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-2500 ng/ml of plasma for both I and II. The lower limit of quantification was 10 ng/ml for I and II. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A throughput of 80 human plasma standards and samples per run was achieved with run time of 5 min for each injection. The assay has been successfully used in analyses of human plasma samples to support clinical studies.  相似文献   

17.
A reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method was developed and validated for determination of aminoflavone (AF) in human plasma. Sample preparation involved a liquid–liquid extraction by the addition of 0.25 mL of plasma with 1.0 mL ethyl acetate containing 50 ng/mL of the internal standard zileuton. The analytes were separated on a Waters X-Terra? MS C18 column using a mobile phase consisting of methanol/water containing 0.45% formic acid (70:30, v/v) and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the AF concentration range of 5–2000 ng/mL in human plasma. The lower limit of quantitation (LLOQ) was 5 ng/mL for AF in human plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical method (<15%). This method was successfully applied to characterize AF plasma concentration-time profile in the cancer patients in a phase I trial.  相似文献   

18.
A quantitative liquid chromatographic-electrospray ionization mass spectrometry method for the determination of naltrexone and 6beta-naltrexol in guinea pig plasma has been developed and validated using naloxone as an internal standard. A single step precipitation-extraction technique was carried out to extract the plasma samples using acetonitrile:ethyl acetate (1:1, v/v). The chromatographic separation was performed on a C(18) column using a mobile phase consisting of 35:65 (v/v) acetonitrile:2 mM ammonium acetate with 0.01 mM ammonium citrate at a flow rate of 0.25 mL/min. The analyte was detected after positive electrospray ionization using selected ion monitoring (SIM) mode. The mean recoveries for naltrexone, naltrexol, and naloxone were 91.7, 89.3, and 99.0%, respectively. The lower limit of quantification (LLOQ) for naltrexone and 6beta-naltrexol was 1.25 ng/mL, and the limit of detection (LOD) was 0.75 ng/mL. The method was applied to a pharmacokinetic study in order to assess the drug disposition of naltrexone in guinea pigs.  相似文献   

19.
A rapid, sensitive, selective and specific HPLC/ESI-MS/MS assay method was developed and validated for the simultaneous quantitation of alpha-/beta-diastereomers of arteether (AE), sulphadoxine (SDX) and pyrimethamine (PYR) in rat blood plasma using propyl ether analogue of beta-arteether as internal standard. The method involved a single-step, liquid-liquid extraction with ethyl acetate and the analytes were chromatographed on a C18 chromatographic column by isocratic elution with methanol:ammonium acetate buffer (10 mM, pH 4) (90:10%, v/v) and analyzed by tandem mass spectrometry. The run time was 4.5 min and the weighted (1/x2) calibration curves were linear over a range of 0.78-400 ng ml-1. The method was validated fully and the lower limit of quantification (LLOQ) in plasma was 0.78 ng ml-1 for all the analytes. The intra- and inter-day precision and accuracy were found to be well within the acceptable limits (<15%) and the analytes were stable after three freeze-thaw (f-t) cycles. The absolute recoveries were consistent and reproducible. The assay method was applied to pre-clinical pharmacokinetic interaction studies of alpha-/beta-AE, SDX and PYR in rats.  相似文献   

20.
Cytochalasin B (CB) was prepared by methanol extraction of dehydrated mold (Drechslera dematioidea) matte, reverse-phase C18 silica gel batch adsorption, selective elution with 1:1 (v/v) hexane:tetrahydrofuran (THF), crystallization, preparative TLC, and recrystallization. Unit gravity silica gel normal phase chromatography afforded additional CB. Yield per liter of medium was 300 mg of CB greater than 95% pure by NMR, HPLC (60:40 hexane:THF, Lichrosorb Si60 silica gel, 230 nm), and TLC. CB added exogenously to mouse organs at 1 and 5 micrograms/organ was recovered 70 to 100% by methanol extraction, adsorption to C18 silica gel Sep-Pak cartridges, elution with ethyl acetate, and analysis by TLC and/or HPLC. Limiting sensitivity (micrograms/extract) was 0.5 TLC; 1.0 HPLC. Quantitative extraction was confirmed with 3H-labeled CB. CB ip in mice at 50 mg/kg (LD10) distributed rapidly into liver, renal fat, kidney, intestines, mesentery, pancreas, spleen, and blood cells and was cleared from all but liver within 24 h. CB was below detectable levels in thymus, lymph nodes, heart, brain, bone marrow, and lungs. Cytochalasin A is fixed to tissues and not extractable. This work affords a source of CB in quantities permitting in vivo study, provides methods for extraction and analysis, and reveals the pharmacokinetics of ip bolus CB.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号