首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 6 毫秒
1.
Screening of newborns for inborn errors of metabolism (IEM) in China is both a challenging and undeveloped area for gynecologists and pediatricians. Since 1999, the Capital Institute of Pediatrics has been studied as regards screening for IEM using advanced gas chromatography–mass spectrometry (GC–MS) method in collaboration with the Matsumoto Institute of Life Science (MILS), Japan, and has successfully diagnosed 51 cases of IEM in a total of 393 patients. Galactosemia, phenylketonuria and methylmalonic acidemia were the most frequent disorders among 51 cases of IEM. Treatment by suitable drugs and/or diet therapy was very effective in the most cases.  相似文献   

2.
Urinary metabolic pattern after the therapeutic peroral dose of dihydrocodeine tartrate to six human volunteers has been explored. Using the GC–MS analytical method, we have found that the major part of the dose administered is eliminated via urine within the first 24 h. However, the analytical monitoring of dihydrocodeine and its metabolites in urine was still possible 72 h after the dose was administered. The dihydrocodeine equivalent amounts excreted in urine in 72 h ranged between 32 and 108% of the dose, on average 62% in all individuals. The major metabolite excreted into urine was a 6-conjugate of dihydrocodeine, then in a lesser amount a 6-conjugate of nordihydrocodeine (both conjugated to approximately 65%). The O-demethylated metabolite dihydromorphine was of a minor amount and was 3,6-conjugated in 85%. Traces of nordihydromorphine and hydrocodone were confirmed as other metabolites of dihydrocodeine in our study. This information can be useful in interpretation of toxicological findings in forensic practice.  相似文献   

3.
Advanced analytical modern technology such as coupling a gas chromatography to a mass spectrometric technique provides sufficient information to the environmental and analytical chemists to identify the presence of a variety of components of the specific volatile organic product, determine the degree of the product weathering and in some instances estimate the age of the product as well in the testing sample. In this study, we estimated BTEX in groundwater sample by using gas chromatography–mass spectrometry (GC–MS) after standardization of this technique for advancement towards purification check of water samples in the petro-polluted regions of the soil.  相似文献   

4.
Molecularly-imprinted polymers in the form of microspheres were synthesized using the dispersion polymerization protocol; cyromazine was used as dummy template, while methacrylic acid, ethylene glycol dimethacrylate and acetonitrile (MeCN) were used as functional monomer, cross-linker, and porogen, respectively. When compared with the non-imprinted polymer, the molecularly-imprinted polymers (MIPs) showed outstanding affinity toward melamine in MeCN with a maximum binding concentration (Bmax) of 53.20 nmol mg−1 MIPs, imprinting effect of 4.6, and a dissociation constant (Kd) of 90.45 μM. After optimization of the molecularly-imprinted solid-phase extraction conditions, a new method was developed to determine the melamine in milk and feed with gas chromatography–mass spectrometry. The performance of this method has been evaluated in the tainted milk and feed in terms of recovery, precision, linearity, the limit of detection (LOD) and limit of quantitation (LOQ). Recovery ranged in samples from 93.1 to 101.3% with intra-day and inter-day relative standard deviation values below 5.34%. The LOD and LOQ of melamine in milk and feed were 0.01 μg mL−1 (μg g−1) and 0.05 μg mL−1 (μg g−1), respectively.  相似文献   

5.
Gas chromatography–mass spectrometry (GC–MS) was compared with gas chromatography–combustion–isotope ratio mass spectrometry (GC–C–IRMS) for measurements of cholesterol 13C enrichment after infusion of labeled precursor ([13C1,2]acetate). Paired results were significantly correlated, although GC–MS was less accurate than GC–C–IRMS for higher enrichments. Nevertheless, only GC–MS was able to provide information on isotopologue distribution, bringing new insights to lipid metabolism. Therefore, we assessed the isotopologue distribution of cholesterol in humans and dogs known to present contrasted cholesterol metabolic pathways. The labeled tracer incorporation was different in both species, highlighting the subsidiarity of GC–MS and GC–C–IRMS to analyze in vivo stable isotope studies.  相似文献   

6.
The simultaneous quantification of 65 plasma steroids, including 22 androgens, 15 estrogens, 15 corticoids and 13 progestins, was developed using gas chromatography-mass spectrometry (GC–MS). The extraction efficiency of the catechol estrogens was improved by the addition of l-ascorbic acid in several steps. All steroids, as their trimethylsilyl derivatives, were well separated with good peak shapes within a 50 min run. The devised method provided good linearity (correlation coefficient, r2 > 0.993), while the limit of quantification ranged from 0.2 to 2.0 ng mL?1. The precision (% CV) and accuracy (% bias) were 2.0–12.4% and 93.5–109.2%, respectively. The metabolic changes were evaluated by applying this method to plasma samples obtained from 26 healthy male subjects grouped according to the pre- and post-administration of dutasteride, which inhibits 5α-reductase isoenzyme types 1 and 2. The levels of three plasma steroids, such as dihydrotestosterone, 5α-androstanedione and allotetrahydrocortisol, were decreased significantly after drug administration, while the levels of testosterone and 5β-androstane-3β,17α-diol were increased. In addition, the ratios of the steroid precursors and their metabolites, which represent the activities of the related enzymes, were z-score transformed for visualization in heat maps generated using supervised hierarchical clustering analysis. These results validated the data transformation because 5α-reductase is an indicator for the biological actions of dutasteride. GC–MS base quantitative visualization might be found in the integration with the mining biomarkers in drug evaluations and hormone-dependent diseases.  相似文献   

7.
A GC–MS assay for stereoselective determination of tramadol and its pharmacologically active phase I metabolite O-desmethyltramadol in human urine was developed. Nefopam was used as internal standard. The method involves a simple solid phase extraction with chiral analysis by gas chromatography–electron ionization mass spectrometry using m/z 263; 58, 249; 58, and 179; 58 for the determination of concentration of tramadol, O-desmethyltramadol and internal standard, respectively. Chromatography was performed on a Rt-βDEXcst column containing alkylated beta-cyclodextrins as a chiral selector. The calibration curves were linear in the concentration range 0.1–20 μg/mL (R2  0.998). Intra-day accuracies ranged between 97.2–104.9%, 96.1–103.2%, and 97.3–102.8% at the lower, intermediate, and high concentration for all analytes, respectively. Inter-day accuracies ranged between 95.2–105.7%, 99.1–105.2%, and 96.5–101.2% at the lower, intermediate, and high concentration for all analytes, respectively. This method was successfully used to determine the concentration of enantiomers of T and ODT in a pharmacogenetic study.  相似文献   

8.
A modified method for the determination of valproylcarnitine in urine samples of patients receiving sodium valproate by gas chromatography—mass spectrometry with selected-ion monitoring is described. The chemically analogous internal standard 2-ethylpentanoylcarnitine was added to the urine samples. Valproic acid and its metabolites were removed by extraction with chloroform at pH 5.0. The samples were then applied onto a C18 Sep-Pak column. Inorganic and water soluble compounds were washed out with water. Valproylcarnitine and internal standard were eluted with methanol and were derivatized to the corresponding acyl-containing lactones by heating at 100°C for 60 min in dimethylformamide. Urinary valproylcarnitine levels of epileptic patients receiving valproate were determined according to the present method. The data obtained might be useful for diagnosis of carnitine deficiency.  相似文献   

9.
A rapid and systematic strategy based on liquid chromatography–mass spectrometry (LC–MS) profiling and liquid chromatography–tandem mass spectrometry (LC–MS–MS) substructural techniques was utilized to elucidate the degradation products of paclitaxel, the active ingredient in Taxol. This strategy integrates, in a single instrumental approach, analytical HPLC, UV detection, full-scan electrospray MS, and MS–MS to rapidly and accurately elucidate structures of impurities and degradants. In these studies, degradants induced by acid, base, peroxide, and light were profiled using LC–MS and LC–MS–MS methodologies resulting in an LC–MS degradant database which includes information on molecular structures, chromatographic behavior, molecular mass, and MS–MS substructural information. The stressing conditions which may cause drug degradation are utilized to validate the analytical monitoring methods and serve as predictive tools for future formulation and packaging studies. Degradation products formed upon exposure to basic conditions included baccatin III, paclitaxel sidechain methyl ester, 10-deacetylpaclitaxel, and 7-epipaclitaxel. Degradation products formed upon exposure to acidic conditions included 10-deacetylpaclitaxel and the oxetane ring opened product. Treatment with hydrogen peroxide produced only 10-deacetylpaclitaxel. Exposure to high intensity light produced a number of degradants. The most abundant photodegradant of paclitaxel corresponded to an isomer which contains a C3–C11 bridge. These methodologies are applicable at any stage of the drug product cycle from discovery through development. This library of paclitaxel degradants provides a foundation for future development work regarding product monitoring, as well as use as a diagnostic tool for new degradation products.  相似文献   

10.
The application of Gas Chromatography (GC)–Atmospheric Pressure Chemical Ionization (APCI)–Time-of-Flight Mass Spectrometry (TOF-MS) is presented for sterol analysis in human plasma. A commercial APCI interface was modified to ensure a well-defined humidity which is essential for controlled ionization. In the first step, optimization regarding flow rates of auxiliary gases was performed by using a mixture of model analytes. Secondly, the qualitative and quantitative analysis of sterols including oxysterols, cholesterol precursors, and plant sterols as trimethylsilyl-derivatives was successfully carried out. The characteristics of APCI together with the very good mass accuracy of TOF-MS data enable the reliable identification of relevant sterols in complex matrices. Linear calibration lines and plausible results for healthy volunteers and patients could be obtained whereas all mass signals were extracted with an extraction width of 20 ppm from the full mass data set. One advantage of high mass accuracy can be seen in the fact that from one recorded run any search for m/z can be performed.  相似文献   

11.
A simple and sensitive method is proposed for the determination of seven low-molecular mass aldehydes in human urine samples using liquid chromatography with tandem mass spectrometric detection. Urine samples diluted twofold with 0.3 M hydrochloric acid are aspirated into a LiChrolut EN solid-phase extraction column impregnated with 2,4-dinitrophenylhydrazine for cleanup, derivatization and preconcentration of the aldehydes. After elution of the hydrazones with acetonitrile, an aliquot is injected directly into the chromatograph. Identification and quantification of aldehydes was performed with electrospray in negative ion mode by selected reaction monitoring. By using synthetic urine samples, linearity is established over the concentration range 0.1–30 μg/l and limits of detection from 15 to 65 ng/l. The intra- and inter-day precision (RSD, %) of the aldehydes ranged from 2.9% to 6.4% and 3.6% to 9.3%, respectively, and specific uncertainties were ca. 5.0 ± 0.3 ng for all aldehydes. Average recoveries performed on two levels by enriching synthetic urine samples ranged between 92% and 100%. The method was also validated in terms of study sample stability including long-term and short-term analyte stability, freeze–thaw and extract stability. In summary, the method proposed surpasses other recent chromatographic alternatives in terms of the limit of detection and sample requirements for analysis.  相似文献   

12.
To conduct studies of stable isotope incorporation and dilution in growing plants, a rapid microscale method for determination of amino acid profiles from minute amounts of plant samples was developed. The method involves solid-phase ion exchange followed by derivatization and analysis by gas chromatography–mass spectrometry (GC–MS). The procedure allowed the eluent to be derivatized directly with methyl chloroformate without sample lyophilization or other evaporation procedures. Sample extraction and derivatization required only ca. 30 min and quantification of the 19 amino acids eluted from the cation exchange solid-phase extraction step from a single cotyledon (0.4 mg fresh weight) or three etiolated 7-day-old Arabidopsis seedlings (0.1 mg fresh weight) was easily accomplished in the selected ion monitoring mode. This method was especially useful for monitoring mass isotopic distribution of amino acids as illustrated by Arabidopsis seedlings that had been labeled with deuterium oxide and 15N salts. Sample preparation was facile, rapid, economical, and the method is easily modified for integration into robotic systems for analysis with large numbers of samples.  相似文献   

13.
A simple, reliable and sensitive gas chromatographic–mass spectrometric method was devised to determine the level of mannitol in various human brain tissues obtained at autopsy. Mannitol was extracted with 10% trichloroacetic acid solution which effectively precipitated brain tissues. The supernatant was washed with tert.-butyl methyl ether to remove other organic compounds and to neutralize the aqueous solution. Mannitol was then derivatized with 1-butaneboronic acid and subjected to GC–MS. Erythritol was used as an internal standard. For quantitation, selected ion monitoring with m/z 127 and 253 for mannitol and m/z 127 for internal standard were used. Calibration curves were linear in concentration range from 0.2 to 20 μg/0.1 g and correlation coefficients exceeded 0.99. The lower detection limit of mannitol in distilled water was 1 ng/0.1 g. Mannitol was detected in control brain tissues, as a biological compound, at a level of 50 ng/0.1 g. The precision of this method was examined with use of two different concentrations, 2 and 20 μg/0.1 g, and the relative standard deviation ranged from 0.8 to 8.3%. We used this method to determine mannitol in brain tissues from an autopsied individual who had been clinically diagnosed as being brain dead. Cardiac arrest occurred 4 days later.  相似文献   

14.
A rapid and sensitive liquid chromatography–electrospray ionization tandem mass spectrometry method (LC–ESI-MS/MS) was developed and validated for the determination of goserelin in rabbit plasma. Various parameters affecting plasma sample preparation, LC separation, and MS/MS detection were investigated, and optimized conditions were identified. Acidified plasma samples were applied to Oasis® HLB solid-phase extraction (SPE) cartridges. Extracted samples were evaporated under a stream of nitrogen and then reconstituted with 100 μL mobile phase A. The separation was achieved on a Capcell-Pak C18 (2.0 mm × 150 mm, 5 μm, AQ type) column with a gradient elution of solvent A (0.05% acetic acid in deionized water/acetonitrile = 85/15; v/v) and solvent B (acetonitrile) at a flow rate of 250 μL/min. The LC–MS/MS system was equipped with an electrospray ion source operating in positive ion mode. Multiple-reaction monitoring (MRM) of the precursor–product ion transitions consisted of m/z 635.7 → m/z 607.5 for goserelin and m/z 424.0 → m/z 292.1 for cephapirin (internal standard). The proposed method was validated by assessing specificity, linearity, limit of quantification (LOQ), intra- and inter-day precision and accuracy, recovery, and stability. Linear calibration curves were obtained in the concentration range of 0.1–20 ng/mL (the correlation coefficients were above 0.99). The LOQ of the method was 0.1 ng/mL. Results obtained from the validation study of goserelin showed good accuracy and precision at concentrations of 0.1, 1, 5, 10, and 20 ng/mL. The validated method was successfully applied to a pharmacokinetic study of goserelin after a single subcutaneous injection of 3.6 mg of goserelin in healthy white rabbits.  相似文献   

15.
The causes and effects of transient neonatal ketosis, discovered during a pilot study of screening for abnormalities in neonatal metabolism using gas chromatography–mass spectrometry, were investigated. Of the 21 342 neonates that were screened, 47 had significant ketosis. The organic acid profile accompanying ketosis in the urine of neonates followed the pattern of ketotic dicarboxylic aciduria in approximately half of the cases. Ketosis was more often found in neonates nourished by breast feeding (33 out of 47). Over half of the neonates showing ketosis (28 out of 47) were asymptomatic. When normal neonates and neonates testing positive for ketosis were compared, no statistically significant correlations were found with regard to birth mass, gestational period, or gender. However, neonates with ketosis tended to have low mass gain rates in the 5 days from birth and a statistically significant difference was found in this regard in comparison to normal neonates (P<0.0001). From the above results, development of ketosis in neonates was found to be possible even in normal subjects. Most ketosis in neonates was also found to depend largely on nourishment after birth. Existence of an asymptomatic ketosis category was also suggested.  相似文献   

16.
YH439 is a potential drug candidate for the treatment of various hepatic disorders. YH439 and its three metabolites have been identified in rat urine by liquid chromatography–mass spectrometry (LC–MS) and by gas chromatography (GC)–MS. Identification of YH439 and its metabolites was established by comparing their GC retention times and mass spectra with those of the synthesized authentic standards. Both electron impact- and positive chemical ionization MS have been evaluated. The metabolism study was performed in the rat using oral administration of the drug. A major metabolite (YH438) was identified as the N-dealkylation product of YH439. Other identified metabolites were caused by the loss of the methyl thiazolyl amine group (metabolite II) from YH439, the isopropyl hydrogen malonate group (metabolite IV) and the decarboxylated product (metabolite III) of metabolite II.  相似文献   

17.
Progress in metabolomic analysis now allows the evaluation of food quality. This study aims to identify the metabolites in meat from livestock using a metabolomic approach. Using gas chromatography–mass spectrometry (GC/MS), many metabolites were reproducibly detected in meats, and distinct differences between livestock species (cattle, pigs, and chickens) were indicated. A comparison of metabolites between tissues types (muscle, intramuscular fat, and intermuscular fat) in marbled beef of Japanese Black cattle revealed that most metabolites are abundant in the muscle tissue. Several metabolites (medium-chain fatty acids, etc.) involved in triacylglycerol synthesis were uniquely detected in fat tissue. Additionally, the results of multivariate analysis suggest that GC/MS analysis of metabolites can distinguish between cattle breeds. These results provide useful information for the analysis of meat quality using GC/MS-based metabolomic analysis.

ABBREVIATIONS: GC/MS: gas chromatography-mass spectrometry; NMR: nuclear magnetic resonance; MS: mass spectrometry; IS: 2-isopropylmalic acid; MSTFA: N-Methyl-N-trimethylsilyltrifluoroacetamide; CV: coefficient of variation; TBS: Tris-buffered saline; MHC: myosin fast type; PCA: principal component analysis; OPLS-DA: orthogonal partial least-squares discriminant analysis; O2PLS: two-way orthogonal partial least-squares  相似文献   


18.
A method for the quantitation of midazolam and its metabolites 1-hydroxymidazolam and 4-hydroxymidazolam from human serum capable of monitoring concentrations achieved under therapeutic conditions is presented. The substances were extracted under basic conditions with toluene and the hydroxy metabolites transformed to their tert-butyldimethylsilyl derivatives with N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide. The samples were measured by gas chromatography–mass spectrometry. The limits of detection are 0.2 ng ml−1 for midazolam and 0.1 ng ml−1 for 1-hydroxy- and 4-hydroxymidazolam. The coefficients of variation are 3.9% at 5 ng ml−1 for midazolam, 6.7% at 2 ng ml−1 for 1-hydroxymidazolam and 8.8% (22.2%) at 0.5 (0.2) ng ml−1 for 4-hydroxymidazolam.  相似文献   

19.
Oxypurinol is the active metabolite of allopurinol which is used to treat hyperuricaemia associated with gout. Both oxypurinol and allopurinol inhibit xanthine oxidase which forms uric acid from xanthine and hypoxanthine. Plasma oxypurinol concentrations vary substantially between individuals and the source of this variability remains unclear. The aim of this study was to develop an HPLC-tandem mass spectrometry method to measure oxypurinol in urine to facilitate the study of the renal elimination of oxypurinol in patients with gout. Urine samples (50 μL) were prepared by dilution with a solution of acetonitrile/methanol/water (95/2/3, v/v; 2 mL) that contained the internal standard (8-methylxanthine; 1.5 mg/L), followed by centrifugation. An aliquot (2 μL) was injected. Chromatography was performed on an Atlantis HILIC Silica column (3 μm, 100 mm × 2.1 mm, Waters) at 30 °C, using a mobile phase comprised of acetonitrile/methanol/50 mM ammonium acetate in 0.2% formic acid (95/2/3, v/v). Using a flow rate of 0.35 mL/min, the analysis time was 6.0 min. Mass spectrometric detection was by selected reactant monitoring (oxypurinol: m/z 150.8 → 108.0; internal standard: m/z 164.9 → 121.8) in negative electrospray ionization mode. Calibration curves were prepared in drug-free urine across the range 10–200 mg/L and fitted using quadratic regression with a weighting factor of 1/x (r2 > 0.997, n = 7). Quality control samples (20, 80, 150 and 300 mg/L) were used to determine intra-day (n = 5) and inter-day (n = 7) accuracy and imprecision. The inter-day accuracy and imprecision was 96.1–104% and <11.2%, respectively. Urinary oxypurinol samples were stable when subjected to 3 freeze–thaw cycles and when stored at room temperature for up to 6 h. Samples collected from 10 patients, not receiving allopurinol therapy, were screened and showed no significant interferences. The method was suitable for the quantification of oxypurinol in the urine of patients (n = 34) participating in a clinical trial to optimize therapy of gout with allopurinol.  相似文献   

20.
An analytical procedure was developed for the determination of 6-mercaptopurine in plasma. Owing to the polar character and low plasma concentrations of the compound, extraction and derivatization was carried out directly from the plasma sample by extractive alkylation. Determination was made using gas chromatography—mass spectrometry with multiple-ion detection.Conditions with respect to the rate of formation and the stability of the derivative formed in the extractive alkylation step were evaluated. The selectivity of the method to azathioprine and to metabolites was thoroughly investigated. No 6-mercaptopurine was formed from azathioprine added to water or plasma and run through the method. The method enables the detection of 2 ng of 6-mercaptopurine in a 1.0-ml plasma sample. Quantitative determinations were done down to 10 ng/ml 6-mercaptopurine in plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号