首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Two simple, sensitive and reproducible methods for determination of total mycophenolic acid (MPA) and its glucuronide metabolite (MPAG) as well as unbound MPA (fMPA) was developed by the use of HPLC-UV and LC-MS/MS methods, respectively. For the total MPA/MPAG method, the analytes were extracted using Isolute C(2) solid-phase extraction (SPE) cartridges and analyzed at 254 nm over a Zorbax Rx C(8) column (150 mm x 4.6 mm, 5 microm). The mobile phase was a gradient mixture of methanol and water (containing 0.1% (v/v) phosphoric acid). The total run time was 18 min and the extraction recovery was 77% for MPA and 84% for MPAG. The method was precise and accurate with a lower limit of quantification (LLOQ) of 0.5 mg/l for MPA and 5.0 mg/l for MPAG. For the fMPA method, plasma was subjected to ultrafiltration followed by SPE using C(18) cartridges. Analytical column was the same as the HPLC-UV method and the mobile phase was a gradient composition of methanol:0.05% formic acid with a flow rate of 0.6 ml/min for the first 3 min and 0.7 ml for the last 4 min. The chromatographic method separated MPA from its metabolites MPAG and Acyl-MPAG. Mass transitions in negative ionization mode for MPA and the internal standard, indomethacin were m/z: 319-->190.9 and m/z: 356-->312.2, respectively. The assay was linear in the concentration range of 1-1000 microg/l for fMPA with a LLOQ of 1 microg/l and an accuracy of >95%. The two methods reported have an adequate degree of robustness and dynamic concentration range for the measurement of MPA, MPAG and fMPA for therapeutic drug monitoring purposes or pharmacokinetics investigations.  相似文献   

2.
A column switching high performance liquid chromatographic method with estimable sensitivity and accuracy was developed for the determination of cetirizine and ambroxol in human plasma using nebivolol as the internal standard. Plasma samples were prepared by liquid-liquid extraction in methylene chloride and a mixture of diethylether (80:20, v/v). The extracted samples were injected into a multifunctional clean-up column Supelcosil LCABZ (50 mm × 4.6 mm, 5 μm particle size) using mobile phase 1 comprising acetonitrile-phosphate buffer (pH 3.5; 20 mM) (20:80, v/v). The eluate of cetirizine and ambroxol were separated to an analytical Kromasil C(8) micro bore column (50 mm × 0.3 mm, 5 μm particle size) via a column switching device. A Kromasil C(18) analytical column (250 mm × 2.1 mm, 5 μm particle size) was used as a separation column. Mobile phase 2 consisting acetonitrile-triethylamine (0.5%) in phosphate buffer (pH 3.5; 20mM) (55:45, v/v) was used for the compound elution. The eluents were detected at 230 nm with photodiode array detector. An aliquot of 150 μl of plasma sample was introduced into the pretreatment column via the auto sampler using mobile phase 1 at a flow rate of 0.5 ml/min, column switching valve being positioned at A. The pretreatment column retained cetirizine, ambroxol and nebivolol (IS) in the column leaving the residual proteins of plasma eluted in void volume and drained out. The switching valve was shifted to position B at 7.5 min. Cetirizine, ambroxol and IS were eluted from the pretreatment column between 7. 5 and 11.5 min and introduced to the concentration column. Finally, cetirizine, ambroxol and IS were introduced to the separation column by switching valve using mobile phase 2 at a flow rate of 0.4 ml/min. During the analysis the pretreatment column was washed for the next analysis and resume to the position A. The total run time was 25 min for a sample. The procedure was repeated for urine analysis also. The method was linear from 2 to 450 ng/ml and 7-300 ng/ml for cetirizine and ambroxol respectively in plasma and 1-500 ng/ml and 5-400 ng/ml, respectively for cetirizine and ambroxol in urine. Intra-day and inter-day precision of cetirizine and ambroxol was below 15% in terms of coefficient of variation and accuracy of cetirizine and ambroxol was ranged from 94 to 101.6% and 91.1 to 100.2%, respectively. The method demonstrated high sensitivity and selectivity and therefore, applied to evaluate pharmacokinetics of cetirizine and ambroxol in healthy human volunteer after a single oral administration. Urine samples obtained from healthy human volunteers and clinical subjects with renal impairment have also been analyzed by the method to compare the elimination pattern. The method was precise and accurate for the estimation of cetirizine and ambroxol both in blood and in urine.  相似文献   

3.
A fast, simple, and a reliable high-performance liquid chromatography linked with electrochemical detector (HPLC-ECD) method for the assessment of lipoic acid (LA) and dihydrolipoic acid (DHLA) in plasma was developed using naproxen sodium as an internal standard (IS) and validated according to standard guidelines. Extraction of both analytes and IS from plasma (250 μl) was carried out with a single step liquid-liquid extraction applying dichloromethane. The separated organic layer was dried under stream of nitrogen at 40°C and the residue was reconstituted with the mobile phase. Complete separation of both compounds and IS at 30°C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 9 min using acetonitrile: 0.05 M phosphate buffer (pH 2.4 adjusted with phosphoric acid) (52:48, v/v) as a mobile phase pumped at flow rate of 1.5 ml min(-1) using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification for lipoic acid were 500 pg/ml and 3 ng/ml, and for dihydrolipoic acid were 3 ng/ml and 10 ng/ml, respectively. The absolute recoveries of lipoic acid and dihydrolipoic acid determined on three nominal concentrations were in the range of 93.40-97.06, and 93.00-97.10, respectively. Similarly coefficient of variations (% CV) for both intra-day and inter-day were between 0.829 and 3.097% for lipoic acid and between 1.620 and 5.681% for dihydrolipoic acid, respectively. This validated method was applied for the analysis of lipoic acid/dihydrolipoic acid in the plasma of human volunteers and will be used for the quantification of these compounds in patients with oxidative stress induced pathologies.  相似文献   

4.
A stereospecific method for simultaneous quantitation of the enantiomers of tramadol (T) and its active metabolites O-demethyl tramadol (M1) and O-demethyl-N-demethyl tramadol (M5) in human plasma is reported. After the addition of penbutolol (IS), plasma (0.5 ml) samples were extracted into methyl tert-butyl ether, followed by back extraction into an acidic solution. The separation was achieved using a Chiralpak AD column with a mobile phase of hexanes:ethanol:diethylamine (94:6:0.2) and a flow rate of 1 ml/min. The fluorescence of analytes was then detected at excitation and emission wavelengths of 275 and 300 nm, respectively. All the six enantiomeric peaks of interest plus three unknown metabolite peaks and IS peak (a total of 10 peaks) eluted within 23 min, free from endogenous interference. The assay was validated in the plasma concentration range of 2.5-250 ng/ml, with a lower limit of quantitation of 2.5 ng/ml, for all the six analytes. The extraction efficiency (n=5) was close to 100% for both T and M1 enantiomers and 85% for M5 and IS enantiomers. The application of the assay was demonstrated by simultaneous measurement of plasma concentrations of T, M1, and M5 enantiomers in a healthy volunteer after the administration of 50 mg oral doses of racemic T.  相似文献   

5.
A novel, simple and fast reversed-phase HPLC/UV method was developed, optimized for various chromatographic conditions, and validated according to international guidelines for simultaneous determination of all-trans-retinol and α-tocopherol in human serum using retinyl acetate as internal standard in the concentration of 0.5 μg/ml. A liquid-phase extraction was applied to the 250 μl of serum with n-hexane–dichloromethane mixture (70:30, v/v), in two steps, using ethanol–methanol mixture (95:5, v/v) for protein precipitation and BHT (butylated hydroxy toluene) as stabilizer for sample preparation. Both analytes were analyzed on Kromasil 100 C18 column (150 mm × 4.6 mm, 5 μm), Brownlee analytical (Perkin Elmer) C18 column (150 mm × 4.6 mm, 5 μm), and Supelco (Supelcosil) LC-18 column (150 mm × 3 mm, 3 μm), protected by a Perkin Elmer C18 (30 mm × 4.6 mm, 10 μm; Norwalk, USA) pre-column guard cartridge, at 292 nm wavelength, using methanol–water (99:1, v/v), in isocratic mode as mobile phase applied at flow rate of 1.5 ml/min and 1 ml/min for both 5 μm and 3 μm columns, respectively. Complete separation of all the analytes was achieved in 3 and 6 min on 3 μm and 5 μm columns, respectively by injecting 20 μl of sample into the HPLC system by autosampler, keeping column oven temperature at 25 °C. Different particulate reversed-phase chromatographic columns were evaluated in order to select the best column in terms of sensitivity, selectivity, resolution and short run time of both the analytes and it was concluded that 3 μm columns are better to be used in clinical set up as well as in laboratories for the separation of these analytes in a shorter time as compared with 5 μm columns. The method was validated and applied for the analysis of all-trans-retinol and α-tocopherol in the serum of human volunteers.  相似文献   

6.
An new method for the determination of polychlorinated biphenyls (PCBs) in serum samples of up to 1 ml has been developed. The procedure consisted in the solid-phase extraction (SPE) of the analytes on an Oasis cartridge and the subsequent on-line elimination of the fat by directly dropping of the eluate from the SPE cartridge on a multilayer column placed below the cartridge. This configuration allowed minimising of the sample manipulation as well as the time, solvent and sorbent consumption (i.e. complete sample preparation can be accomplished in about 1 h with only 3 ml of toluene and 300 mg of silica). The SPE plus clean-up method developed showed a satisfactory performance for the analysis of PCBs in rat serum samples providing similar recoveries (i.e. range 73-128% for most of the congeners selected) at the different spiking levels investigated (1.25, 0.50 and 0.25 ng/ml). Detection limits using a microelectron capture detector were in the range 0.01-0.30 ng/ml of serum and the relative standard deviations of the complete method better than 18% irrespective of the PCB concentration. The validated method has been applied to the evaluation for the first time of the PCB levels in serum samples of up to 1 ml from individuals of an Egyptian Vulture colony in Spain.  相似文献   

7.
For the determination of cisapride from serum samples, an automated microbore high-performance liquid chromatographic method with column switching has been developed. After serum samples (100 μl) were directly injected onto a Capcell Pak MF Ph-1 pre-column (10×4 mm I.D.), the deproteinization and concentration were carried out by acetonitrile–phosphate buffer (20 mM, pH 7.0) (2:8, v/v) at valve position A. At 2.6 min, the valve was switched to position B and the concentrated analytes were transferred from MF Ph-1 pre-column to a C18 intermediate column (35×2 mm I.D.) using washing solvent. By valve switching to position A at 4.3 min, the analytes were separated on a Capcell Pak C18 UG 120 column (250×1.5 mm I.D.) with acetonitrile–phosphate buffer (20 mM, pH 7.0) (5:5, v/v) at a flow-rate of 0.1 ml/min. Total analysis time per sample was 18 min. The linearity of response was good (r=0.999) over the concentration range of 5–200 ng/ml. The within-day and day-to-day precision (CV) and inaccuracy were less than 3.7% and 3.8%, respectively. The mean recovery was 96.5±2.4% with the detection limit of 2 ng/ml.  相似文献   

8.
New bioanalytical SPE-HPLC-PDA-FL method for the determination of the neuroleptic drug tiapride and its N-desethyl metabolite was developed, validated and applied to xenobiochemical and pharmacokinetic studies in humans and animals. The sample preparation process involved solid-phase extraction of diluted plasma spiked with sulpiride (an internal standard) using SPE cartridges DSC-PH Supelco, USA. Chromatographic separation of the extracts was performed on a Discovery HS F5 250 mm × 4 mm (Supelco) column containing pentafluorophenylpropylsilyl silica gel. Mobile phase (acetonitrile-0.01 M phosphate buffer pH=3, flow rate 1 ml min(-1)) in the gradient mode was employed in the HPLC analysis. Tandem UV photodiode-array→fluorescence detection was used for the determination of the analytes. Low concentrations of tiapride and N-desethyl tiapride were determined using a more selective fluorescence detector (λ(exc.)/λ(emiss.)=232 nm/334 nm), high concentrations (500-6000 pmol ml(-1)) using a UV PDA detector at 212 nm with a linear response. Each HPLC run lasted 15 min. Lower limits of quantification (LLOQ) for tiapride (N-desethyl tiapride) were found to be 8.24 pmol ml(-1) (10.11 pmol ml(-1)). The recoveries of tiapride ranged from 89.3 to 94.3%, 81.7 to 86.8% for internal standard sulpiride and 90.9 to 91.8% for N-desethyl tiapride.  相似文献   

9.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

10.
A simple and reliable method for analyzing the concentrations of clozapine and its biologically active metabolite, norclozapine, in human serum or plasma has been developed. This method is based on reversed-phase high-performance liquid chromatography (HPLC) with automated solid-phase extraction (SPE). For HPLC analysis, samples and standards are prepared with an ASPEC automatic sample preparator using 100 mg Bond-Elut C18 SPE columns. The HPLC assay is an isocratic method with a mobile phase of acetonitrile-methanol-10 mM dipotassium hydrogenphosphate, pH 3.7 (30:2:100, v/v/v) at a flow-rate of 1.5 ml/min with a C18 reversed-phase column. Detection is performed with a diode array detector set at 220 nm and with peak purity analyses at 210–365 nm. The absolute recovery varied from 85 and 95%. The intra-assay coefficients of variation (C.V.s) were from 4.2 and 8.0% and the inter-assay C.V.s were from 1.1. to 9.3% at therapeutic drug concentrations. The detection limit is 15 nmol/l. The method has been developed for use in a clinical laboratory for therapeutic drug monitoring.  相似文献   

11.
Two novel metabolites of benproperine (BPP), 1-[1-methyl-2-[2-(phenylmethyl)phenoxy]ethyl]-3-piperidinol (3-OH-BPP) and 1-[1-methyl-2-[2-(phenylmethyl)phenoxy]ethyl]-4-piperidinol (4-OH-BPP), were confirmed by comparison of retention times and mass spectra with those of synthetic standards using liquid chromatography-tandem mass spectrometry. Selective and sensitive procedures were developed for the simultaneous determination of BPP, 3-OH-BPP and 4-OH-BPP in human plasma and urine. The analytes were extracted from plasma sample and enzymatically hydrolyzed urine samples by liquid-liquid extraction, separated through a Diamonsil C(18) column (150 mm x 4.6 mm i.d.) and determined by tandem mass spectrometry with an electrospray ionization interface in selected reaction monitoring mode. Dextromethorphan was used as internal standard. The mobile phase consisted of acetonitrile-water-formic acid (34:66:1, v/v/v), and flow-rate was 0.5 ml min(-1). This method has a lower limit of quantification (LLOQ) of 60, 4.0 and 4.0 nmol l(-1)for BPP, 3-OH-BPP and 4-OH-BPP in plasma, 4.9, 4.7 and 2.4 nmol l(-1) in urine, respectively. The intra- and inter-run precision were measured to be below 9.2%, and the accuracy was within +/-4.3% for the analytes. The method was successfully used to determine BPP, 3-OH-BPP and 4-OH-BPP in plasma and urine for pharmacokinetic investigation. The results indicated residue of 3-OH-BPP in the body at least 192 h after an oral dose of BPP.  相似文献   

12.
A high throughput bioanalytical method based on solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS), has been developed for the estimation of perindopril and its metabolite perindoprilat, an angiotensin-converting enzyme inhibitor in human plasma. Ramipril was used as internal standard (IS). The extraction of perindopril, perindoprilat and ramipril from the plasma involved treatment with phosphoric acid followed by solid phase extraction (SPE) using hydrophilic lipophilic balance HLB cartridge. The SPE eluate without drying were analyzed by LC-MS/MS, equipped with turbo ion spray (TIS) source, operating in the negative ion and selective reaction monitoring (SRM) acquisition mode to quantify perindopril and perindoprilat in human plasma. The total chromatographic run time was 1.5 min with retention time for perindopril, perindoprilat and ramipril at 0.33, 0.35 and 0.30 min. The developed method was validated in human plasma matrix, with a sensitivity of 0.5 ng/ml (CV, 7.67%) for perindopril and 0.3 ng/ml (CV, 4.94%) for perindoprilat. This method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect especially because the pattern of elution of all the analytes appears as flow injection elution. Sample preparation by this method yielded extremely clean extracts with very good and consistent mean recoveries; 78.29% for perindopril, 76.32% for perindoprilat and 77.72% for IS. The response of the LC-MS/MS method for perindopril and perindoprilat was linear over the range 0.5-350.0 ng/ml for perindopril and 0.3-40 ng/ml for perindoprilat with correlation coefficient, r>/=0.9998 and 0.9996, respectively. The method was successfully applied for bioequivalence studies in human subjects samples with 4 mg immediate release (IR) formulations.  相似文献   

13.
A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its three metabolites O-desmethylvenlafaxine (ODV), N-desmethylvenlafaxine (NDV) and N,O-didesmethylvenlafaxine (DDV) in human plasma has been developed and validated. Estazolam was used as the internal standard. The compounds and internal standard were extracted from plasma by a liquid-liquid extraction. The HPLC separation of the analytes was performed on a Thermo BDS HYPERSIL C18 (250 mm x 4.6 mm, 5 microm, USA) column, using a gradient elution program with solvents constituted of water (ammonium acetate: 30 mmol/l, formic acid 2.6 mmol/l and trifluoroacetic acid 0.13 mmol/l) and acetonitrile (60:40, V/V) at a flow-rate of 1.0 ml/min. All of the analytes were eluted within 6 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and were detected in the selected ion recording (SIR) mode. Calibration curves in spiked whole blood were linear from 4.0-700 ng/ml, 2.0-900 ng/ml, 3.0-800 ng/ml and 2.0-700 ng/ml for VEN, ODV, NDV and DDV, respectively, all of them with coefficients of determination above 0.9991. The average extraction recoveries for all the four analytes were above 77%. The methodology recoveries were higher than 91%. The limits of detection were 0.4, 0.2, 0.3, and 0.2 ng/ml for VEN, ODV, NDV and DDV, respectively. The intra- and inter-day variation coefficients were less than 11%. The method is accurate, sensitive and reliable for the pharmacokinetic study of venlafaxine as well as therapeutic drug monitoring (TDM).  相似文献   

14.
A sensitive and relatively rapid reversed-phase HPLC method was applied to the enantiomeric separation of tramadol and its two main metabolites, O-desmethyltramadol (M1) and N-desmethyltramadol (M2) in plasma samples. Chromatography was performed on an AGP column containing alpha1-acid glycoprotein as chiral selector with a mobile phase of 30 mM diammonium hydrogen phosphate buffer-acetonitrile-triethylamine (98.9:1:0.1, v/v), adjusted to pH 7 by phosphoric acid, and a flow rate of 0.5 ml/min. The fluorescence of analytes was detected at excitation and emission wavelengths of 200 and 301 nm, respectively. The sample preparation was a simple extraction with ethyl acetate using fluconazol as internal standard (IS). The enantiomers of all analytes and IS peaks eluted within 32 min, without any endogenous interference. The calibration curves were linear (r(2) > 0.993) in the concentration range of 2-200, 2.5-100 and 2.5-75 ng/ml for tramadol, M1, and M2 enantiomers, respectively. The within- and between-day variation determined by the measurement of quality control samples at four tested concentrations, showed acceptable values. The lower limit of quantitation was 2 ng/ml for tramadol enantiomers and 2.5 ng/ml for M1 or M2 enantiomers. Mean recoveries of enantiomers from plasma samples were > 81% for all analytes. The procedure was applied to assess the pharmacokinetics of the enantiomers of tramadol and its two main metabolites following oral administration of single 100-mg doses to healthy volunteers.  相似文献   

15.
Analytical method for the simultaneous determination of dextromethorphan (1) and dextrorphan (2) in urine, based on solid-phase extraction of drug from acidified hydrolyzed biological matrix, were developed. The analytes (1 and 2) and the internal standard (levallorphan, 3, IS) were detected by high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) in positive ionization mode using a heated nebulizer (HN) probe and monitoring their precursor-->product ion combinations of m/z 272-->215, 258-->201, and 284-->201 for 1, 2, and 3, respectively, in multiple reaction monitoring mode. The analytes and IS were chromatographed on a Keystone Prism reverse phase (50 mm x 2.0 mm) 5 microm column using a mobile phases consisting of a 35/65 or 27/73 mixtures of methanol/water containing 0.1% TFA adjusted to pH 3 with ammonium hydroxide pumped at 0.4 ml/min for 1 and 2, respectively. The limits of reliable quantification of 1 and 2 were 2 and 250 ng/ml, respectively, when 1 ml of urine was processed. The absence of matrix effect was demonstrated by analysis of neat standards and standards spiked into urine extracts originating from five different sources. The linear ranges of the assay were 2-200 and 250-20,000 ng/ml for 1 and 2, respectively. Assay selectivity was evaluated by monitoring the "cross-talk" effects from other metabolites into the MS/MS channels used for monitoring 1, 2, and 3. In addition, an interfering peak originating from an unknown metabolite of 1 into the quantification of dextromethorphan was detected, requiring an effective chromatographic separation of analytes from other metabolites of 1. The need for careful assessment of selectivity of the HPLC-MS/MS assay in the presence of metabolites, and the assessment of matrix effect, are emphasized.  相似文献   

16.
A rapid on-line solid phase extraction/liquid chromatography/tandem mass spectrometry (SPE/LC/MS/MS) method using restricted access material (RAM) was developed for the simultaneous determination of eight organophosphorus triesters in untreated human blood plasma. In a process involving column-switching techniques, the analytes were enriched on the RAM column, separated using a C-18 analytical column and detected with LC/MS. Tandem mass spectrometry was used to characterize and quantify the analytes. To elucidate the fragmentation pathway of a number of the analytes, MS3 experiments using an ion trap mass spectrometer were performed. The matrix effects associated with using APCI and ESI interfaces were investigated. The recoveries obtained were in the range 60-92% (R.S.D.<6%), with estimated detection limits between 0.2 and 1.8 ng/ml of plasma, and the total analysis time was 27 min.  相似文献   

17.
Voriconazole is a novel broad-spectrum antifungal agent. We developed an on-line LC-LC-MS-MS method for fully automated and direct analysis of voriconazole in raw human serum. After injection of human serum size-selective sample fractionation and analyte extraction was achieved using an extraction column (25 mm x 4 mm) packed with a restricted access material (RAM, LiChrospher ADS C(8), 25 microm). On-line transfer of voriconazole from the extraction column was followed by chromatography separation on a C(18) column. Detection was done by ESI-MS-MS. The total analysis time was 13 min, managed by parallel extraction and chromatographic separation. This LC-MS assay was fully validated. The lower limit of quantification was 0.05 microg/ml. The automated inline extraction of voriconazole described here eliminates the need for difficult and time-consuming sample pre-treatment. Other advantages of the new method are that only a small quantity (5 microl) of serum is needed and that the method is very specific.  相似文献   

18.
Analytical methods for the determination of ximelagatran, an oral direct thrombin inhibitor, its active metabolite melagatran, and intermediate metabolites, melagatran hydroxyamidine and melagatran ethyl ester, in biological samples by liquid chromatography (LC) positive electrospray ionization mass spectrometry (MS) using selected reaction monitoring are described. Isolation from human plasma was achieved by solid-phase extraction on octylsilica. Analytes and isotope-labelled internal standards were separated by LC utilising a C(18) analytical column and a mobile phase comprising acetonitrile-4 mmol/l ammonium acetate (35:65, v/v) containing 0.1% formic acid, at a flow-rate of 0.75 ml/min. Absolute recovery was approximately 80% for ximelagatran, approximately 60% for melagatran ethyl ester and >90% for melagatran and melagatran hydroxyamidine. Limit of quantification was 10 nmol/l, with a relative standard deviation <20% for each analyte and <5% above 100 nmol/l. Procedures for determination of these analytes in human urine and breast milk, plus whole blood from rat and mouse are also described.  相似文献   

19.
A selective and high throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated to separate, detect and simultaneously quantify lamivudine (3TC), stavudine (d4T) and nevirapine (NVP) in human plasma using metaxalone as internal standard (IS). After solid phase extraction (SPE), the analytes and the IS were chromatographed on a Symmetry C18 (150 mmx3.9 mm i.d., 5 microm particle size) column using 5 microL injection volume with a run time of 4.5 min. An isocratic mobile phase consisting of 0.5% glacial acetic acid in water:acetonitrile (20:80, v/v) was used to separate all these drugs. The precursor and product ions of these drugs were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring mode (MRM) without polarity switch. The method was validated over the range of 25-3000 ng/mL for 3TC, 20-2000 ng/mL for d4T and 50-5000 ng/mL for NVP. The absolute recoveries for analytes (>or=86%) and IS (98.12%) achieved from spiked plasma samples were consistent and reproducible. Inter-batch and intra-batch precision (%CV) across four validation runs (LLOQ, LQC, MQC and HQC) was less than 10. The accuracy determined at these levels was within +/-8% in terms of relative error. The method was successfully applied to a pivotal bioequivalence study of [60 (3TC)+12 (d4T)+100 (NVP)] mg dispersible tablets in 60 healthy human subjects under fasting condition.  相似文献   

20.
On irradiation with ultraviolet light, the antiinflammatory agent sulindac and its two metabolites sulindac sulfone and sulindac sulfide form highly fluorescent derivatives. This reaction was exploited for the sensitive and selective detection of these compounds in serum using reversed-phase high-performance liquid chromatography on a Ultrasphere octylsilane column (150 × 4.6 mm I.D.) at ambient temperature with a flow-rate of 0.5 ml/min. The analytes of interest were isolated from serum using a Bond-Elut C2 column with satisfactory recovery and selectivity. The detection limits were 10 ng/ml for each of the three analytes using 1 ml of serum and the limit of quantitation was 50 ng/ml. Linear calibration curves from 50 to 1000 ng/ml for all three analytes show coefficients of determination of 0.9999. The post-column ultraviolet irradiation was optimized and the effect of irradiation time on the fluorescence response was determined for all three analytes. Precision and accuracy of the method were 0.4–5.6 and 1.6–4.5% for sulindac, 2.3–5.6 and 1.4–5.3% for sulindac sulfone and 2.5–4.3 and 0.8–2.8% for sulindac sulfide, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号