首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The performance of aerated and ferricyanide catholytes on the bioelectricity production was evaluated in dual chambered microbial fuel cell (MFC) (mediatroless anode; graphite electrodes) employing selectively enriched H(2) producing mixed consortia as anodic inoculum. Two MFCs with aerated catholyte (MFC(AC)) and ferricyanide catholyte (MFC(FC)) were operated separately to elucidate the difference in power generation potential and carbon removal efficiency under similar operating conditions [ambient pressure; room temperature (28+/-2 degrees C); acidophilic microenvironment (pH 6)]. The experimental data demonstrated the feasibility of in situ bioelectricity generation along with wastewater treatment. Effective power generation and substrate removal efficiency was documented in the fuel cell operated with ferricyanide catholyte (586 mV; 2.37 mA; 0.559 kg COD/m(3) day) than aerated catholyte (572 mV; 1.68 mA; 0.464 kg COD/m(3) day). Maximum power yield (0.635 W/kg COD(R) and 0.440 W/kg COD(R)) and current density (222.59 mA/m(2) and 190.28 mA/m(2)) was observed at 100 Omega resistor with ferricyanide and aerated catholytes, respectively. The study documented both wastewater treatment and electricity production through direct conversion of H(2) in a single system.  相似文献   

2.
A biodiesel wastewater treatment technology was investigated for neutral alkalinity and COD removal by microbial fuel cell. An upflow bio-filter circuit (UBFC), a kind of biocatalyst MFC was renovated and reinvented. The developed system was combined with a pre-fermented (PF) and an influent adjusted (IA) procedure. The optimal conditions were operated with an organic loading rate (OLR) of 30.0 g COD/L-day, hydraulic retention time (HRT) of 1.04 day, maintained at pH level 6.5-7.5 and aerated at 2.0 L/min. An external resistance of circuit was set at 10 k?. The purposed process could improve the quality of the raw wastewater and obtained high efficiency of COD removal of 15.0 g COD/L-day. Moreover, the cost of UBFC system was only US$1775.7/m3 and the total power consumption was 0.152 kW/kg treated COD. The overall advantages of this invention are suitable for biodiesel wastewater treatment.  相似文献   

3.
Functional role of biomolecules viz., carbohydrates and proteins on acidogenic biohydrogen (H2) production was studied through the treatment of canteen based composite food waste. The performance was evaluated in an anaerobic sequencing batch reactor (AnSBR) at pH 6 with five variable organic loading conditions (OLR1, 0.854; OLR2, 1.69; OLR3, 3.38; OLR4, 6.54 and OLR5, 9.85 kg COD/m3-day). Experimental data depicted the feasibility of H2 production from the stabilization of food waste and was found to depend on the substrate load. Among the five loading conditions studied, OLR4 documented maximum H2 production (69.95 mmol), while higher substrate degradation (3.99 kg COD/m3-day) was observed with OLR5. Specific hydrogen yield (SHY) vary with the removal of different biomolecules and was found to decrease with increase in the OLR. Maximum SHY was observed with hexose removal at OLR1 (139.24 mol/kg HexoseR at 24 h), followed by pentoses (OLR1, 108.26 mol/kg PentoseR at 48 h), proteins (OLR1, 109.71 mol/kg ProteinR at 48 h) and total carbohydrates (OLR1, 58.31 mol/kg CHOR at 24 h). Proteins present in wastewater helped to maintain the buffering capacity but also enhanced the H2 production by supplying readily available organic nitrogen to the consortia. Along with carbohydrates and proteins, total solids also registered good removal.  相似文献   

4.
The influence of substrate loading rate on fermentative hydrogen (H2) production was studied in biofilm configured sequencing batch reactor using chemical wastewater as substrate. Reactor was operated with selectively enriched anaerobic mixed microflora at different organic loading rates (OLRs; 6.3, 7.1 and 7.9kg COD/m3 day) after adjusting the feed to a pH of 6.0 (acidophilic) to provide suitable environment for acidogenic bacterial function. Variation in H2 production rate was observed with change in OLR [specific hydrogen yield - 13.44molH2/kgCODRday (6.3kgCOD/m3day), 8.23molH2/kgCODRday (7.1kgCOD/m3 day) and 6.064molH2/kgCODR day (7.9kgCOD/m3 day)]. H2 yield showed reasonably good correlation with pH drop [6.3kgCOD/m3 day (R2 - 0.9796), 7.1kgCOD/m3 day (R2 - 0.9973), 7.9kgCOD/m3 day (R2 - 0.9908)]. Increase in OLR showed marked reduction in COD removal efficiency [22.6% - 6.3kgCOD/m3 day; 19.8% - 7.1kgCOD/m3 day and 17.2% - 7.9kgCOD/m3 day].  相似文献   

5.
Single chambered mediatorless microbial fuel cell (MFC; non-catalyzed electrodes) was operated to evaluate the potential of bioelectricity generation from the treatment of composite waste vegetables (EWV) extract under anaerobic microenvironment using mixed consortia as anodic biocatalyst. The system was operated with designed synthetic wastewater (DSW; 0.98 kg COD/m3-day) during adaptation phase and later shifted to EWV and operated at three substrate load conditions (2.08, 1.39 and 0.70 kg COD/m3-day). Experimental data illustrated the feasibility of bioelectricity generation through the utilization of EWV as substrate in MFC. Higher power output (57.38 mW/m2) was observed especially at lower substrate load. The performance of MFC was characterized based on the polarization behavior, cell potentials, cyclic voltammetric analysis and sustainable resistance. MFC operation also documented to stabilize the waste by effective removal of COD (62.86%), carbohydrates (79.84%) and turbidity (55.12%).  相似文献   

6.
In this study, performance of a lab-scale hybrid up-flow anaerobic sludge blanket (UASB) reactor, treating a chemical synthesis-based pharmaceutical wastewater, was evaluated under different operating conditions. This study consisted of two experimental stages: first, acclimation to the pharmaceutical wastewater and second, determination of maximum loading capacity of the hybrid UASB reactor. Initially, the carbon source in the reactor feed came entirely from glucose, applied at an organic loading rate (OLR) 1 kg COD/m(3) d. The OLR was gradually step increased to 3 kg COD/m(3) d at which point the feed to the hybrid UASB reactor was progressively modified by introducing the pharmaceutical wastewater in blends with glucose, so that the wastewater contributed approximately 10%, 30%, 70%, and ultimately, 100% of the carbon (COD) to be treated. At the acclimation OLR of 3 kg COD/m(3) d the hydraulic retention time (HRT) was 2 days. During this period of feed modification, the COD removal efficiencies of the anaerobic reactor were 99%, 96%, 91% and 85%, and specific methanogenic activities (SMA) were measured as 240, 230, 205 and 231 ml CH(4)/g TVS d, respectively. Following the acclimation period, the hybrid UASB reactor was fed with 100% (w/v) pharmaceutical wastewater up to an OLR of 9 kg COD/m(3) d in order to determine the maximum loading capacity achievable before reactor failure. At this OLR, the COD removal efficiency was 28%, and the SMA was measured as 170 ml CH(4)/g TVS d. The hybrid UASB reactor was found to be far more effective at an OLR of 8 kg COD/m(3) d with a COD removal efficiency of 72%. At this point, SMA value was 200 ml CH(4)/g TVS d. It was concluded that the hybrid UASB reactor could be a suitable alternative for the treatment of chemical synthesis-based pharmaceutical wastewater.  相似文献   

7.
Bio (microbial) fuel cell (microbial fuel cell) with Saccharomyces cerevisiae as anodic biocatalyst was evaluated in terms of power generation and substrate degradation at three redox conditions (5.0, 6.0 and 7.0). Fuel cell was operated in single chamber (open-air cathode) configuration without mediators using non-catalyzed graphite as electrodes. The performance was further studied with increasing loading rate (OLRI, 0.91 kg COD/m3-day; OLRII, 1.43 kg COD/m3). Higher current density was observed at pH 6.0 [160.36 mA/m2 (OLRI); 282.83 mA/m2 (OLRII)] than pH 5.0 (137.24 mA/m2) and pH 7.0 (129.25 mA/m2). Bio-electrochemical behavior of fuel cell was evaluated using cyclic voltammetry which showed the presence of redox mediators (NADH/NAD+; FADH/FAD+). Higher electron discharge was observed at pH 6.0, suggesting higher proton shuttling through the involvement of different redox mediators. The application of yeast based fuel cell can be extended to treat high strength wastewaters with simultaneous power generation.  相似文献   

8.
Influence of recirculation on the performance of anaerobic sequencing batch biofilm reactor (AnSBBR) was studied in the process of treating hypersaline (total dissolved inorganic solids (TDIS) approximately 26 g/l) and low biodegradable (BOD/COD approximately 0.3) composite chemical wastewater. Significant enhancement in the substrate removal efficiency and biogas yield was observed after introducing the recirculation to the system. Maximum efficiency (COD removal efficiency - 51%; SDR - 3.14 kg COD/cum-day) was observed at recirculation to feed (R/F) ratio of 2 (OLR - 6.15 kg C OD/cum-day; HLR - 2.30 cum (liquid)/cum day; UFV(A) - 0.023 m/h). Subsequent increase of R/F to 3 (OLR - 6.15 kg COD/cum-day; HLR - 3.07cum (liquid)/cum-day; UFV(A) - 0.035 m/h) resulted in reduction in COD removal efficiency (32%; SDR - 1.97 kg COD/cum-day). The enhanced performance of the system due to the introduction of recirculation was attributed to the improvement in the mass transfer between the substrate present in the bulk liquid and the attached biofilm. The hydrodynamic behavior due to recirculation mode of operation reduced the concentration gradient (substrate inhibition) of substrate and reaction by-products (VFA) resulting in mixed flow conditions.  相似文献   

9.
Two SBR reactors were set up to investigate the feasibility of aerobic granulation under the combined selection pressures of hydraulic shear force and substrate loading. Aerobic granulation was studied at superficial upflow air velocity of 3.2 and 2.4 cm/s under an organic loading rate (OLR) range of 6.0-15.0 kg COD/m3d. Good reactor performance and well granule characteristics were achieved in a wide OLR range from 6.0 high up to 15.0 kg COD/m3d at 3.2 cm/s. While under the velocity of 2.4 cm/s, stable operation was limited in the OLR range of 6.0-9.0 kg COD/m3d and failed to operate with granule deterioration under further higher OLRs. The optimal combination of hydrodynamic shear force and loading selection pressure was demonstrated to be an important factor that influence aerobic granulation and govern the granule characteristics and reactor performance.  相似文献   

10.
During field application, the microbial fuel cell (MFC) will be exposed to variations in operating parameters. Hence, the performance of MFC, exposed to variation in temperature, pH, external resistance and influent chemical oxygen demand (COD), was investigated in the terms of coulombic efficiency (CE) and COD removal efficiency, while treating a synthetic wastewater. The performance was analyzed under two temperature ranges such as 20-35 degrees C and 8-22 degrees C. Operation under higher temperature range favored higher COD removal efficiency of 90% and lower current (0.7 mA) and CE (1.5%). At lower temperature range, although the COD removal efficiency of MFC decreased (59%), it gave higher current (1.4 mA) and CE (5%). The highest current was generated at pH of 6.5 in the anodic chamber with CE of 4%. Higher pH difference between anodic and cathodic electrolyte favored higher current and voltage. Within the range of COD tested (100-600 mg/l), linear correlation was observed between the current and substrate removed.  相似文献   

11.
The effect of temperature and organic loading rate on the rate of methane production from acidic petrochemical wastewater without neutralization was investigated by continuously feeding an anaerobic upflow fixed-film reactor. The temperatures selected for the studies were 25, 37, 45 and 55 degrees C. Organic loading rate (OLR) for each temperature was varied from 3.6 to 21.7 kg COD m(-3) d(-1). Best performance with respect to COD and BOD reduction, total gas production and methane yield was obtained with the reactor operating at 37 degrees C. OLR could be increased to a maximum of 21.7 kg COD m(-3) d(-1) with 90-95% COD and BOD reduction and methane yield of 0.450 m3 kg(-1) COD d(-1) added. The reactor operating at 55 degrees C gave the highest methane yield of 0.666 m3 kg(-1) COD d(-1) at an OLR of 6 kg COD m(-3) d(-1). This decreased to 0.110 m3 kg(-1) COD d(-1) when the OLR was increased to 18.1 kg COD m(-3) d(-1). The reactor operating at 45 degrees C gave a maximum methane yield of 0.416 m3 kg(-1) COD d(-1) added at an OLR of 6 kg COD m(-3) d(-1). On further increasing the OLR to 9 kg COD m(-3) d(-1), COD reduction was 89%, however, methane yield decreased to 0.333 m3 kg(-1) COD d(-1) added. The highest methane yield of 0.333 m3 kg(-1) COD d(-1) added at an OLR of 6 kg COD m(-3) d(-1) was obtained with reactors operating at 25 degrees C. These studies indicate potential rates of methane production from acidic petrochemical wastewater under different temperatures. This provides a guideline for various kinetic analyses and economic evaluation of the potential feasibility of fermenting acidic wastewater to methane.  相似文献   

12.
The effect of anodic biofilm growth and extent of its coverage on the anodic surface of a single chambered mediatorless microbial fuel cell (MFC) was evaluated for bioelectricity generation using designed synthetic wastewater (DSW) and chemical wastewater (CW) as substrates and anaerobic mixed consortia as biocatalyst. Three MFCs (plain graphite electrodes, air cathode, Nafion membrane) were operated separately with variable biofilm coverage [control; anode surface coverage (ASC), 0%], partially developed biofilm [PDB; ASC approximately 44%; 90 days] and fully developed biofilm [FDB; ASC approximately 96%; 180 days] under acidophilic conditions (pH 6) at room temperature. The study depicted the effectiveness of anodic biofilm formation in enhancing the extracellular electron transfer in the absence of mediators. Higher specific power production [29mW/kg COD(R) (CW and DSW)], specific energy yield [100.46J/kg VSS (CW)], specific power yield [0.245W/kg VSS (DSW); 0.282W/kg VSS (CW)] and substrate removal efficiency of 66.07% (substrate degradation rate, 0.903kgCOD/m(3)-day) along with effective functioning fuel cell at relatively higher resistance [4.5kOmega (DSW); 14.9kOmega (CW)] correspond to sustainable power [0.008mW (DSW); 0.021mW (CW)] and effective electron discharge (at higher resistance) and recovery (Coulomb efficiency; 27.03%) were observed especially with FDB operation. Cyclic voltammetry analysis documented six-fold increment in energy output from control (1.812mJ) to PDB (10.666mJ) operations and about eight-fold increment in energy from PDB to FDB (86.856mJ). Biofilm configured MFC was shown to have the potential to selectively support the growth of electrogenic bacteria with robust characteristics, capable of generating higher power yields along with substrate degradation especially operated with characteristically complex wastewaters as substrates.  相似文献   

13.
The Taguchi robust experimental design (DOE) methodology has been applied on a dynamic anaerobic process treating complex wastewater by an anaerobic sequencing batch biofilm reactor (AnSBBR). For optimizing the process as well as to evaluate the influence of different factors on the process, the uncontrollable (noise) factors have been considered. The Taguchi methodology adopting dynamic approach is the first of its kind for studying anaerobic process evaluation and process optimization. The designed experimental methodology consisted of four phases--planning, conducting, analysis, and validation connected sequence-wise to achieve the overall optimization. In the experimental design, five controllable factors, i.e., organic loading rate (OLR), inlet pH, biodegradability (BOD/COD ratio), temperature, and sulfate concentration, along with the two uncontrollable (noise) factors, volatile fatty acids (VFA) and alkalinity at two levels were considered for optimization of the anae robic system. Thirty-two anaerobic experiments were conducted with a different combination of factors and the results obtained in terms of substrate degradation rates were processed in Qualitek-4 software to study the main effect of individual factors, interaction between the individual factors, and signal-to-noise (S/N) ratio analysis. Attempts were also made to achieve optimum conditions. Studies on the influence of individual factors on process performance revealed the intensive effect of OLR. In multiple factor interaction studies, biodegradability with other factors, such as temperature, pH, and sulfate have shown maximum influence over the process performance. The optimum conditions for the efficient performance of the anaerobic system in treating complex wastewater by considering dynamic (noise) factors obtained are higher organic loading rate of 3.5 Kg COD/m3 day, neutral pH with high biodegradability (BOD/COD ratio of 0.5), along with mesophilic temperature range (40 degrees C), and low sulfate concentration (700 mg/L). The optimization resulted in enhanced anaerobic performance (56.7%) from a substrate degradation rate (SDR) of 1.99 to 3.13 Kg COD/m3 day. Considering the obtained optimum factors, further validation experiments were carried out, which showed enhanced process performance (3.04 Kg COD/m3-day from 1.99 Kg COD/m3 day) accounting for 52.13% improvement with the optimized process conditions. The proposed method facilitated a systematic mathematical approach to understand the complex multi-species manifested anaerobic process treating complex chemical wastewater by considering the uncontrollable factors.  相似文献   

14.
Liu X  Ren N  Yuan Y 《Bioresource technology》2009,100(1):104-110
A four-compartment periodic anaerobic baffled reactor (PABR) was run in a 'clockwise sequential' switching manner continuously fed on chinese traditional medicine industrial wastewater under an alkalinity concentration between 1000 and 1500 mg CaCO(3)/L of the feed with average organic load rate (OLR) at about 1, 2, 4 and 6 kg COD/(m(3)d) for 12, 24, 24 and 6d, respectively. Hydraulic residence time was 2d, while switching period was 4d. As the average OLR increased to 6 kg COD/(m(3)d), the time of the sharp fall in pH, chemical oxygen demand (COD) removal, gas production and methane percentage of the biogas of all the compartments and the time of rapid volatile fatty acids accumulation in effluent coincided, hence the PABR became sour. Denaturing gradient gel electrophoresis (DGGE) community fingerprints and their cluster analysis revealed that community structures of each compartment tended to be more closely related if the PABR was not overloaded.  相似文献   

15.
Anaerobic treatment of wastewater from a selected seafood processing plant was conducted at organic loading rates (OLR) ranging from 0.3 to 1.8 kg chemical oxygen demand (COD)/m3.day and hydraulic retention times (HRT) ranging from 36 to 6 days. COD reduction decreased with increasing OLR. More than 75% COD reduction could be maintained up to an OLR of about 1 kg COD/m3.day with an HRT of 11 days. An OLR of 1.3 kg COD/m3.day corresponding to an HRT of 6.6 days gave maximal biogas productivity of 1.5 m3/m3.day or 1.3 m3 biogas/kg COD with a 65% COD reduction. If the HRT was kept constant at 11 days, an OLR of 1.3 kg COD/m3.day achieved maximal biogas productivity (1.1 m3/m3.day) and yield (0.75 m3/kg COD) and a 60% COD reduction for treatment of tuna condensate.P. Prasertsan and S. Jung are with the Department of Agro-Industry, Faculty of Natural Resources, Prince of Songkla University, Hatyai 90110, Thailand. K.A. Buckle is with the Department of Food Science and Technology, University of New South Wales, Kensington, NSW 2033, Australia.  相似文献   

16.
Li Z  Yao L  Kong L  Liu H 《Bioresource technology》2008,99(6):1650-1655
To make sure that microbial fuel cells (MFCs) are more convenient to stack, a baffled single-chambered MFC with two groups of electrodes sharing only one anode chamber was designed and the performance was examined. The experiments showed that the prototype MFC generated electrical power (maximum of 133 mW/m(2)) while removing up to 88% of chemical oxygen demand (COD) in 91 h. Volumetric power increased as electrode area per anode compartment volume increased, indicating that the MFC with two groups of electrodes was better than that with one group. Power density as a function of wastewater concentration was modeled according to saturation kinetics, with a maximum power density of P(max)=164 mW/m(2) (fixed 100 Omega resistor) and half-saturation concentration of K(s)=259 mg/l. The hydraulic retention time (HRT) was examined as a factor influencing the power generation. When it was 15.5h, the voltage and the power density reached the maximum 0.413 V and 108 mW/m(2).  相似文献   

17.
This study aims at evaluating the performance of a two-chambered continuously fed microbial fuel cell with new Ti–TiO2 electrodes for bioelectricity generation from young landfill leachate at varying strength of wastewater (1–50 COD g/L) and hydraulic retention time (HRT, 0.25–2 days). The COD removal efficiency in the MFC increased with time and reached 45 % at full-strength leachate (50 g/L COD) feeding. The current generation increased with increasing leachate strength and decreasing HRT up to organic loading rate of 100 g COD/L/day. The maximum current density throughout the study was 11 A/m2 at HRT of 0.5 day and organic loading rate of 67 g COD/L/day. Coulombic efficiency (CE) decreased from 57 % at feed COD concentration of 1 g/L to less than 1 % when feed COD concentration was 50 g/L. Increase in OLR resulted in increase in power output but decrease in CE.  相似文献   

18.
Summary A high-strength baker's yeast effluent was anaerobically treated using a hybrid digester under mesophilic conditions. The digester was subjected to a substrate COD concentration of 21 767 mg/I at three different HRTs. At HRTs of 3.0, 2.0 and 1.0 d, the digester reduced the substrate COD by 76, 61 and 33%, respectively. Although the best COD removal was obtained at an OLR of 7.30 kg COD/m3.d, the highest COD removal rate (6.51 kg COD/M3-d) was found at 10.65 kg COD/m3.d at an HRT of 2.0 d. The low methane yield and VFA accumulation found in the digester effluent, indicated inhibition on methanogenic level and this was considered to be the rate-limiting step during the anaerobic treatment process. The overall efficiency of the digester indicated that this digester design and support medium was suitable for the treatment of a high-strength, sulfate-rich baker's yeast effluent.  相似文献   

19.

Varying chemical oxygen demand (COD) and sulphate concentrations in substrate were used to determine reaction kinetics and mass balance of organic matter and sulphate transformation in a microbial fuel cell (MFC). MFC with anodic chamber volume of 1 L, fed with wastewater having COD of 500 mg/L and sulphate of 200 mg/L, could harvest power of 54.4 mW/m2, at a Coulombic efficiency of 14%, with respective COD and sulphate removals of 90 and 95%. Sulphide concentration, even up to 1500 mg/L, did not inhibit anodic biochemical reactions, due to instantaneous abiotic oxidation to sulphur, at high inlet sulphate. Experiments on abiotic oxidation of sulphide to sulphur revealed maximum oxidation taking place at an anodic potential of −200 mV. More than 99% sulphate removal could be achieved in a MFC with inlet COD/sulphate of 0.75, giving around 1.33 kg/m3 day COD removal. Bioelectrochemical conversion of sulphate facilitating sulphur recovery in a MFC makes it an interesting pollution abatement technique.

  相似文献   

20.
Lim SJ  Fox P 《Bioresource technology》2011,102(4):3724-3729
A static granular bed reactor (SGBR) was used to treat swine wastewater at 24 and 16 °C. At 24 °C, the organic loading rate (OLR) was 0.7-5.4 kg COD/m3 day and the average chemical oxygen demand (COD) removal efficiency was 88.5%, respectively. Meanwhile, at 16 °C, the OLR was 1.6-4.0 kg COD/m3 day and the average COD removal efficiency was 68.0%, respectively. The SGBR acted as a bioreactor as well as a biofilter. After backwashing, the recovery of COD removal was not a function of an OLR but recovery time, while that of TSS removal was not a function of either recovery time or the OLR. The maximum substrate utilization rate (kmax) ratio was 1.89 between 24 and 16 °C, and the half velocity constant (Ks) ratio was 1.22, and the maximum specific growth rate (μmax) ratio was 4.71. In addition, the temperature-activity coefficient in this study was determined to be 1.09.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号