首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, the excellent catalytic activity of highly ordered mesoporous carbons (OMCs) to the electrooxidation of nicotinamide adenine dinucleotide (NADH) and hydrogen peroxide (H(2)O(2)) was described for the construction of electrochemical alcohol dehydrogenase (ADH) and glucose oxidase (GOD)-based biosensors. The high density of edge-plane-like defective sites and high specific surface area of OMCs could be responsible for the electrocatalytic behavior at OMCs modified glassy carbon electrode (OMCs/GE), which induced a substantial decrease in the overpotential of NADH and H(2)O(2) oxidation reaction compared to carbon nanotubes modified glassy carbon electrode (CNTs/GE). Such ability of OMCs permits effective low-potential amperometric biosensing of ethanol and glucose, respectively, at Nafion/ADH-OMCs/GE and Nafion/GOD-OMCs/GE. Especially, as an amperometric glucose biosensor, Nafion/GOD-OMCs/GE showed large determination range (500-15,000mumoll(-1)), high sensitivity (0.053nAmumol(-1)), fast (9+/-1s) and stable response (amperometric response retained 90% of the initial activity after 10h stirring of 2mmoll(-1) glucose solution) to glucose as well as the effective discrimination to the possible interferences, which may make it to readily satisfy the need for the routine clinical diagnosis of diabetes. By comparing the electrochemical performance of OMCs with that of CNTs as electrode material for the construction of ADH- and GOD-biosensors in this work, we reveal that OMCs could be a favorable and promising carbon electrode material for constructing other electrochemical dehydrogenase- and oxidase-based biosensors, which may have wide potential applications in biocatalysis, bioelectronics and biofuel cells.  相似文献   

2.
Direct electrochemistry and thermal stability of hemoglobin (Hb) immobilized on a nanometer-sized zirconium dioxide (ZrO2) modified pyrolytic graphite (PG) electrode were studied. The immobilized Hb displayed a couple of stable and well-defined redox peaks with an electron transfer rate constant of (7.90 +/- 0.93)s(-1) and a formal potential of -0.361 V (-0.12 V versus NHE) in 0.1M pH 7.0 PBS. Both nanometer-sized ZrO2 and dimethyl sulfoxide (DMSO) could accelerate the electron transfer between Hb and the electrode. Spectroscopy analysis of the Hb/ZrO2/DMSO film showed that the immobilized Hb could retain its natural structure. This modified electrode showed a high thermal stability up to 74 degrees C and an electrocatalytic activity to the reduction of hydrogen peroxide (H2O2) without the aid of an electron mediator. The electrocatalytic response showed a linear dependence on the H2O2 concentration ranging from 1.5 to 30.2 microM with a detection limit of 0.14 microM at 3sigma. The apparent Michaelis-Menten constant KMapp for H2O2 sensor was estimated to be (0.31 +/- 0.02) mM, showing a high affinity.  相似文献   

3.
Kang X  Mai Z  Zou X  Cai P  Mo J 《Analytical biochemistry》2007,363(1):143-150
Copper (Cu) nanoclusters were electrochemically deposited on the film of a Nafion-solubilized multiwall carbon nanotube (CNTs)-modified glassy carbon electrode (CNTs-GCE), which fabricated a Cu-CNTs composite sensor (Cu-CNTs-GCE) to detect glucose with nonenzyme. Transmission electron microscopy (TEM) and X-ray diffraction (XRD) were used for the characterization of the distribution of the Cu nanoclusters on the CNTs matrix. The composite of the Cu-CNTs was investigated by the electrochemical characterization of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The preliminary study shows that the nonenzymatic sensor has synergistic electrocatalytic activity to the oxidation of glucose in alkaline media. A well applicable sensor was constructed to use for the analysis of the glucose in real blood serum samples due to the large number of electrons taking part in the oxidation process, the high apparent kinetic rate constant, and the stable operation of the electrode. The linear range for the detection of the glucose is 7.0 x 10(-7) to 3.5 x 10(-3) M with a high sensitivity of 17.76 microA mM(-1), a low detection limit of 2.1 x 10(-7) M, and a fast response time of within 5s. Experiment results also showed that the sensor has good reproducibility and long-term stability and is interference free.  相似文献   

4.
Flavin adenine dinucleotide (FAD)-modified zinc oxide self-assembly films were prepared using repeated cyclic voltammetry. The electrochemical reaction of the hemoglobin with the FAD/ZnO self-assembly film-modified electrodes and their electrocatalytic properties were investigated. This paper describes the successful loading of the electrochemically active molecules of hemoglobin and FAD along with ZnO by electrochemical method. In addition to the cyclic voltammetry, an electrochemical quartz crystal microbalance was used to study the growth mechanism and the properties of the films. The FAD/zinc oxide films exhibited a single redox couple, which corresponded to the FAD redox couple. The electrocatalytic properties of the O2, H2O2, trichloroacetic acid and SO(3)2- were studied by the FAD/zinc oxide films in the absence or in the presence of hemoglobin. The electrocatalytic reduction current had been developed from the cathodic peak of the FAD/zinc oxide redox couple. The electrocatalytic process involved an interaction of hemoglobin and FAD/GC film-modified electrode to increase the electrocatalytic reduction current. The electrocatalytic reduction of O2 using the FAD/zinc oxide films was investigated by cyclic voltammetry and rotating ring-disk electrode methods.  相似文献   

5.
A convenient and effective strategy for preparation nanohybrid film of multi-wall carbon nanotubes (MWNT) and gold colloidal nanoparticles (GNPs) by using proteins as linker is proposed. In such a strategy, hemoglobin (Hb) was selected as model protein to fabricate third-generation H2O2 biosensor based on MWNT and GNPs. Acid-pretreated, negatively charged MWNT was first modified on the surface of glassy carbon (GC) electrode, then, positively charged Hb was adsorbed onto MWNT films by electrostatic interaction. The {Hb/GNPs}n multilayer films were finally assembled onto Hb/MWNT film through layer-by-layer assembly technique. The assembly of Hb and GNPs was characterized with cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and transmission electron microscopy (TEM). The direct electron transfer of Hb is observed on Hb/GNPs/Hb/MWNT/GC electrode, which exhibits excellent electrocatalytic activity for the reduction of H2O2 to construct a third-generation mediator-free H2O2 biosensor. As compared to those H2O2 biosensors only based on carbon nanotubes, the proposed biosensor modified with MWNT and GNPs displays a broader linear range and a lower detection limit for H2O2 determination. The linear range is from 2.1x10(-7) to 3.0x10(-3) M with a detection limit of 8.0x10(-8) M at 3sigma. The Michaelies-Menten constant KMapp value is estimated to be 0.26 mM. Moreover, this biosensor displays rapid response to H2O2 and possesses good stability and reproducibility.  相似文献   

6.
Laccase from Trametes hirsuta basidiomycete has been covalently bound to graphite electrodes electrochemically modified with phenyl derivatives as a way to attach the enzyme molecules with an adequate orientation for direct electron transfer (DET). Current densities up to 0.5mA/cm(2) of electrocatalytic reduction of O(2) to H(2)O were obtained in absence of redox mediators, suggesting preferential orientation of the T1 Cu centre of the laccase towards the electrode. The covalent attachment of the laccase molecules to the functionalized electrodes permitted remarkable operational stability. Moreover, O(2) bioelectroreduction based on DET between the laccase and the electrode was not inhibited by chloride ions, whereas mediated bioelectrocatalysis was. In contrast, fluoride ions inhibited both direct and mediated electron transfers-based bioelectrocatalytic reduction of O(2). Thus, two different modes of laccase inhibition by halides are discussed.  相似文献   

7.
A micro-biosensor was constructed by incorporating the organic conducting salt tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ) into a platinized platinum (Pt) wire and further covering with the electrochemical polymerical heteropolypyrrole film, in which glucose oxidase (GOx) was entrapped. The enzyme electrode can sensitively determine glucose at a low working potential, mainly based on the oxidation of H2O2. The incorporated TTF-TCNQ can significantly improve the oxidation of H2O2 on the electrode, although a part of the TTF-TCNQ functions as a mediator. Compared with the same electrode prepared without TTF-TCNQ incorporated, the TTF-TCNQ modified electrode had better performance characteristics at a working potential of 200 mV (versus SCE). The response time to 90% of the steady value was shortened from about 40 s to less than 10 s, the lower limit of the linear response was greatly extended from about 1.6 mM to 10 microM, the linear range was shifted from 1.6-10.0 to 0.01-5 mM and the sensitivity was increased from about 1 to 1.5 microA/mM. The electrode was quite stable. For continuous operation, the electrode could work for about 5 weeks and only lost 60% of its original sensitivity. Stored at 4 degrees C for intermittent determinations, the electrode kept 80% sensitivity for over 6 months. Due to covering the electrode with a non-conductive heteropolypyrrole film, ascorbate, urate and 4-acetamidophenol caused only negligible current response at an applied potential of 200 mV.  相似文献   

8.
Horseradish peroxidase (HRP) was successfully immobilized on vertically oriented TiO(2) nanotube arrays (NTAs), which was prepared by a seeded-growth mechanism. The nanotubular structure of TiO(2) was characterized by scanning electron microscope (SEM). After encapsulated HRP on TiO(2) nanotube arrays, the direct electron transfer of HRP was observed. Owing to the redox reaction of electroactive center of HRP, the HRP/TiO(2) NTAs modified electrode exhibited a pair of quasi-reversible peaks with the peak-to-peak separation of 70mV and the formal potential of -0.122V (vs. SCE) in 0.2molL(-1) phosphate buffer solution (PBS, pH 7.0). The number of transference electron was 0.84 and the direct electron transfer (ET) constant (k(s)) was 3.82s(-1). The HRP/TiO(2) NTAs modified electrode displayed an excellent electrocatalytic performance for H(2)O(2) and the formal Michaelis-Menten constant (K(m)(app)) was 1.9mmolL(-1). The response currents had a good linear relation with the concentration of H(2)O(2) from 5.0x10(-7)molL(-1) to 1.0x10(-5)molL(-1) and 5.0x10(-5)molL(-1) to 1.0x10(-3)molL(-1), respectively.  相似文献   

9.
This paper introduces the use of multi walled carbon nanotubes (MWCNTs) with palladium (Pd) nanoparticles in the electrocatalytic reduction of hydrogen peroxide (H(2)O(2)). We have developed and characterized a biosensor for H(2)O(2) based on Nafion(?) coated MWCNTs-Pd nanoparticles on a glassy carbon electrode (GCE). The Nafion(?)/MWCNTs-Pd/GCE electrode was easily prepared in a rapid and simple procedure, and its application improves sensitive determination of H(2)O(2). Characterization of the MWCNTs-Pd nanoparticle film was performed with transmission electron microscopy (TEM), Raman, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) and amperometry (at an applied potential of -0.2V) measurements were used to study and optimize performance of the resulting peroxide biosensor. The proposed H(2)O(2) biosensor exhibited a wide linear range from 1.0 μM to 10 mM and a low detection limit of 0.3 μM (S/N=3), with a fast response time within 10s. Therefore, this biosensor could be a good candidate for H(2)O(2) analysis.  相似文献   

10.
Direct electrochemical and electrocatalytic behaviors of hemoglobin (Hb) immobilized on carbon paste electrode (CPE) by a silica sol-gel film derived from tetraethylorthosilicate (TEOS) were investigated for the first time. Hb/sol-gel film modified electrodes showed a pair of well-defined and nearly reversible cyclic voltammetric peaks for Hb Fe(III)/Fe(II) redox couple at about -0.312 V (versus Ag/AgCl) in a pH 7.0 phosphate buffer. The formal potential of Hb heme Fe(III)/Fe(II) couple varied linearly with the increase of pH in the range of 5.0-10.0 with a slope of 49.44 mV pH(-1), which suggests that a proton transfer is accompanied with each electron transfer (ET) in the electrochemical reaction. The immobilized Hb displayed the features of peroxidase and gave excellent electrocatalytic performance to the reduction of O2, NO2(-) and H2O2. The calculated apparent Michaelis-Menten constant was 8.98 x 10(-4)M, which indicated that there was a large catalytic activity of Hb immobilized on CPE by sol-gel film toward H2O2. In comparison with other electrodes, the chemically modified electrodes, used in this direct electrochemical study of Hb, are easy to be fabricated and rather inexpensive. Consequently, the Hb/sol-gel film modified electrode provides a convenient approach to perform electrochemical research on this kind of proteins. It also has potential use in the fabrication of the third generation biosensors and bioreactors.  相似文献   

11.
Poly(ionic liquid) (PIL) coated ordered mesoporous carbons (OMCs) were prepared by in situ polymerization of 3-ethyl-1-vinylimidazolium tetrafluoroborate ([VEIM]BF(4)) monomer on OMCs matrix. PIL on the surface of OMCs can provide sufficient binding sites to anchor the precursors of metal ion. PIL/OMCs were employed as support material for the deposition and formation of ultra-fine Pt nanoparticles, via the self-assembly between the negative Pt precursor and positively charged functional groups of PIL-functionalized OMCs. The combination of the unique properties of each component endows Pt/PIL/OMCs as a good electrode material. Compared with the Pt/OMCs nanocomposite, the Pt/PIL/OMCs modified electrode displays high electrocatalytic activity towards hydrogen peroxide (H(2)O(2)) and gives linear range from 1.0 × 10(-7) to 3.2 × 10(-3) M (R=0.999). The Pt/PIL/OMCs responds very rapidly to the changes in the level of H(2)O(2), producing steady-state signals within 4-5s. A high sensitivity of 24.43 μA mM(-1) and low detection limit of 0.08 μM was obtained at Pt/PIL/OMCs modified electrode towards the reduction of H(2)O(2). The improved activity makes Pt/PIL/OMCs nanocomposite promising for being developed as an attractive robust and new electrode material for electrochemical sensors and biosensors design.  相似文献   

12.
The direct electron transfer of immobilized horseradish peroxidase (HRP) on silica-hydroxyapatite (HAp) hybrid film-modified glassy carbon electrode (GCE) and its application as H(2)O(2) biosensors were investigated. On silica/HRP-HAp/GCE, HRP displayed a fast electron transfer process accompanied with one proton participate in. This sensor exhibited an excellent electrocatalytic response to the reduction of H(2)O(2) without the aid of an electron mediator. The proposed biosensor showed good reproducibility and high sensitivity to H(2)O(2) with the detection limit of 0.35 microM. In the range of 1.0-100 microM, the catalytic reduction current of H(2)O(2) was proportional to H(2)O(2) concentration. The apparent Michaelis-Menten constant (k(m)(app)) of the biosensor was calculated to be 21.8 microM, exhibiting a high enzymatic activity and affinity for H(2)O(2).  相似文献   

13.
Direct electron transfer of immobilized horseradish peroxidase on gold colloid and its application as a biosensor were investigated by using electrochemical methods. The Au colloids were associated with a cysteamine monolayer on the gold electrode surface. A pair of redox peaks attributed to the direct redox reaction of horseradish peroxidase (HRP) were observed at the HRP/Au colloid/cysteamine-modified electrode in 0.1 M phosphate buffer (pH 7.0). The surface coverage of HRP immobilized on Au colloid was about 7.6 x 10(-10) mol/cm(2). The sensor displayed an excellent electrocatalytic response to the reduction of H(2)O(2) without the aid of an electron mediator. The calibration range of H(2)O(2) was 1. 4 microM to 9.2 mM with good linear relation from 1.4 microM to 2.8 mM. A detection limit of 0.58 microM was estimated at a signal-to-noise ratio of 3. The sensor showed good reproducibility for the determination of H(2)O(2). The variation coefficients were 3. 1 and 3.9% (n = 10) at 46 microM and 2.8 mM H(2)O(2), respectively. The response showed a Michaelis-Menten behavior at higher H(2)O(2) concentrations. The K(app)(M) value for the H(2)O(2) sensor was found to be 2.3 mM.  相似文献   

14.
Electrochemistry of microperoxidase-11 (MPx-11) anchored on the mixed self-assembled monolayer (SAM) of 2-(2-mercaptoethylpyrazine) (PET) and 4,4'-dithiodibutyric acid (DTB) on gold (Au) electrode and the biosensing of uric acid (UA) is described. MPx-11 has been covalently anchored on the mixed SAM of PET and DTB on Au electrode. MPx-11 on the mixed self-assembly exhibits reversible redox response characteristic of a surface confined species. The heterocyclic ring of PET promotes the electron transfer between the electrode and the redox protein. The apparent standard rate constant kapps obtained for the redox reaction of MPx-11 on the mixed monolayer is approximately 2.15 times higher than that on the single monolayer of DTB modified electrode. MPx-11 efficiently mediates the electrocatalytic reduction of H2O2. MPx-11 electrode is highly sensitive to H2O2 and it shows linear response for a wide concentration range. The electrocatalytic activity of the MPx-11 electrode is combined with the enzymatic activity of uricase (UOx) to fabricate uric acid biosensor. The bienzyme assembly is highly sensitive towards UA and it could detect UA as low as 2 microM at the potential of -0.1 V. The biosensor shows linear response with a sensitivity of 3.4+/-0.08 nA cm(-2) microM(-1). Ascorbate (AA) and paracetamol (PA) do not significantly interfere in the amperometric sensing of UA.  相似文献   

15.
Herein, we reported for the first time one step procedure for the preparation of cytochrome c (cyt c)-poly (5-amino-2-napthalenesulfonic acid) (PANS) modified glassy carbon electrode by cyclic voltammetrically (CV). Hereafter, we called the above modified electrode as cyt c-PANS electrode. The presence of cyt c on modified electrode was investigated with electrochemical quartz crystal microbalance (EQCM), CV, and superoxide radicals reaction studies. The reaction between cyt c in the modified electrode and superoxide radicals in solution, was exemplified by cyclic voltammetric measurements. Surface morphology of the modified electrode was investigated by using atomic force microscopy (AFM). The modified electrode showed a pair of well defined redox peak in PBS solution, pH 6.7. The modified electrode utilized for electrocatalytic reduction as well as amperometric determination of hydrogen peroxide (H(2)O(2)). The detection limit and linear range for H(2)O(2) were 5 and 50 microM to 7 mM, respectively.  相似文献   

16.
Cui L  Yin H  Dong J  Fan H  Liu T  Ju P  Ai S 《Biosensors & bioelectronics》2011,26(7):3278-3283
An enzymeless biosensor was explored from Cu-Mg-Al calcined layered double hydroxide (CLDH) modified electrode in this study. The Cu-Mg-Al CLDH greatly promotes the electron transfer between H(2)O(2) and GCE, and it is exemplified toward the non-enzymatic sensing of H(2)O(2). The results indicate that the Cu-Mg-Al CLDH exhibits excellent electrocatalytic property, high sensitivity, good reproducibility, long-term stability, and fast amperometric response toward reduction of H(2)O(2), thus is promising for the future development of man-made mimics of enzyme in H(2)O(2) sensors. This work opens a way to utilize simply Cu-Mg-Al CLDH as an electron mediator to fabricate an efficient H(2)O(2) biosensor, which exhibits great potential applications in varieties of simple, robust, and easy-to-make analytical approaches in the future.  相似文献   

17.
The direct electrocatalytic oxidation of glucose in alkaline medium at nanoscale nickel hydroxide modified carbon ionic liquid electrode (CILE) has been investigated. Enzyme free electro-oxidation of glucose have greatly been enhanced at nanoscale Ni(OH)(2) as a result of electrocatalytic effect of Ni(+2)/Ni(+3) redox couple. The sensitivity to glucose was evaluated as 202 microA mM(-1)cm(-2). From 50 microM to 23 mM of glucose can be selectively measured using platelet-like Ni(OH)(2) nanoscale modified CILE with a detection limit of 6 microM (S/N=3). The nanoscale nickel hydroxide modified electrode is relatively insensitive to electroactive interfering species such as ascorbic acid (AA), and uric acid (UA) which are commonly found in blood samples. Long-term stability, high sensitivity and selectivity as well as good reproducibility and high resistivity towards electrode fouling resulted in an ideal inexpensive amperometric glucose biosensor applicable for complex matrices.  相似文献   

18.
Nanoporous silver (NPS) and copper (NPC) obtained by dealloying AgAl and CuAl alloys, respectively, were used as both three-dimensional templates and reducing agents for the fabrication of nanoporous PtAg (NPS-Pt) and PtCu (NPC-Pt) alloys with hollow ligaments by a simple galvanic replacement reaction with H(2)PtCl(6). Electron microscopy and X-ray diffraction characterizations demonstrate that NPS and NPC with similar ligament sizes (30-50 nm) have different effects on the formed hollow nanostructures. For NPS-Pt, the shell of the hollow ligament is seamless. However, the shell of NPC-Pt is comprised of small pores and alloy nanoparticles with a size of ~3 nm. The as-prepared NPS-Pt and NPC-Pt exhibit remarkably improved electrocatalytic activities towards the oxidation of ethanol and H(2)O(2) compared with state-of-the-art Pt/C catalyst, and can be used for sensitive electrochemical sensing applications. The hierarchical nanoporous structure also provides a good microenvironment for enzymes. After immobilization of glucose oxidase (GOx), the enzyme modified nanoporous electrode can sensitively detect glucose in a wide linear range (0.6-20 mM).  相似文献   

19.
A simple and sensitive method for the electrocatalytic detection of NADH on a carbon paste electrode modified with a redox-active (NC)(2)C(6)H(3)-NO/(NC)(2)C(6)H(3)-NHOH (NOPH/NHOHPH) electrogenerated in situ from 4-nitrophthalonitrile (4-NPHN) is presented. The electrode modified with 4-NPHN showed an efficient electrocatalytic activity towards the oxidation of NADH with activation overpotential of 0.12V vs. Ag/AgCl. The formation of an intermediate charge transfer complex is proposed for the charge transfer reaction between NADH and the 4-NPHN-resulting system. The second-order rate constant for electrocatalytic oxidation of NADH, kappa(obs), and the apparent Michaelis-Menten constant K(M), at pH 7.0 were evaluated with rotating disk electrode (RDE) experiments, giving 1.0x10(4)mol(-1)Ls(-1) and 2.7x10(-5)molL(-1), respectively. Employing the Koutecky-Levich approach indicated that the NADH oxidation reaction involves two electrons. The sensor provided a linear response range for NADH from 0.8 up to 8.5mumolL(-1) with sensitivity, detection, quantification limits and time response of 0.50muALmumol(-1), 0.25mumolL(-1), 0.82mumolL(-1) and 0.1s, respectively. The repeatability of the measurements with the same sensor and different sensors, evaluated in terms of relative standard deviation, were 4.1 and 5.0%, respectively, for n=10.  相似文献   

20.
A novel hydrogen peroxide biosensor was fabricated by using a DNA-Cu(II) complex as a novel electrocatalyst for the reduction of hydrogen peroxide (H2O2). A polyion complex (PIC) membrane composed of DNA and poly(allylamine) (PAA) functioned as a support matrix for immobilization of electrocatalytic element-copper ion. The circular dichroism (CD) spectrum of the DNA-Cu(II)/PAA membrane in wet state showed that the DNA exists in B-like form within the membrane. Electrochemical measurements of the DNA-Cu(II)/PAA membrane-modified glassy carbon (GC) electrode revealed that the copper ion embedded in the DNA/PAA layer exhibits good electrochemical behaviors, and the electrochemical rate constant between the immobilized copper ion and the GC electrode surface was estimated to be 26.4 s(-1). The resulting DNA-Cu(II)/PAA/GC electrode showed an excellent electrocatalytic activity for the H2O2 reduction. The sensitivity of the sensor for the determination of H2O2 was affected by the amount of each component, such as copper ion, DNA and PAA in the DNA-Cu(II)/PAA membrane. Effects of applied potential, pH, temperature, ionic strength and buffer concentrations upon the response currents of the sensor were also investigated for an optimum analytical performance. Even in the presence of dissolved oxygen, the sensor exhibited highly sensitive and rapid (response time, less than 5 s) response to H2O2. The steady-state cathodic current responses of the sensor obtained at -0.2 V versus Ag/AgCl in air-saturated 50 mM phosphate buffer (pH 5.0) increased linearly up to 135 microM with the detection limit of 50 nM. Interference by ascorbic acid and uric acid due to the reduction of Cu(II) was effectively cancelled by further modification of outermost layer of polyion complex film. In addition, the sensor exhibited good reproducibility and stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号