首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type-1 (HIV-1) are transfusion-transmitted human pathogens that have a major impact on blood safety and public health worldwide. We developed a microarray multiplex assay for the simultaneous detection and discrimination of these three viruses. The microarray consists of 16 oligonucleotide probes, immobilized on a silylated glass slide. Amplicons from multiplex PCR were labeled with Cy-5 and hybridized to the microarray. The assay detected 1 International Unit (IU), 10 IU, 20 IU of HBV, HCV, and HIV-1, respectively, in a single multiplex reaction. The assay also detected and discriminated the presence of two or three of these viruses in a single sample. Our data represent a proof-of-concept for the possible use of highly sensitive multiplex microarray assay to screen and confirm the presence of these viruses in blood donors and patients.  相似文献   

2.
The implementation of nucleic acid amplification technology (NAT) for detection of HCV, HIV-1 and HBV has undoubtedly contributed to the viral safety of blood, reducing the window period. One important matter related to the stability of RNA/DNA is the effect of the storage conditions on samples. In a previous work, we studied the stability of HCV RNA in plasma samples after storage at different temperatures. This work is an update on the follow-up of a sample containing 100 IU/ml HCV RNA for 5 years at -20 degrees C, showing no decrease in the initial titre. The nucleic acid stability of other viruses, such as HIV-1 and HBV, has also been studied. At -20 degrees C, samples containing HIV-1 were followed up for approximately 3 years and the results obtained show no decay in HIV-1 RNA detectability. Regardless of the HIV-1 RNA concentration, samples stored at 5 degrees C maintain their titre for at least 14 days. At 25 degrees C, the HIV-1 RNA half-life was determined at nearly 7 days. The HBV DNA, at 5 degrees C and 25 degrees C, is stable for at least 28 days, regardless of the initial titre.  相似文献   

3.
This study evaluated the performance characteristics of the AmpliScreen(TM)Human Immunodeficiency Virus-Type 1 (HIV-1) Test, Version 1.5, a test designed for screening pools composed of samples from individual units of blood or plasma. HIV-1, hepatitis C (HCV) and hepatitis B (HBV) virus particles were simultaneously extracted and concentrated from plasma by a multi-prep sample processing procedure. An HIV-1 Internal Control (IC) RNA was added to each sample to serve as an extraction and amplification control. Processed samples were amplified by RT-PCR using HIV-1-specific complementary primers and detected by hybridization of the amplified products to HIV-1- and IC-specific oligonucleotide probes.The analytical sensitivity of the test (concentration that yields >/=95% positive results in a set of replicate tests) was 25 copies of HIV-1 RNA per mL of pooled plasma. Representative strains from all HIV-1 group M subtypes were reproducibly detected (>95% positive results among 22 replicate tests) at concentrations of 30 to 75 viral particles per ml. The test exhibited excellent specificity; it did not cross-react with a set of 30 viral and five bacterial isolates and yielded negative results on a panel of 500 blood samples from HIV-1 seronegative donors. Samples containing abnormally high levels of haemoglobin, albumin, triglycerides or bilirubin in plasma samples did not interfere with the detection of HIV-1 RNA at a concentration of 100 copies of per ml. The test detected HIV-1 RNA 7-17 days prior to anti-HIV-1 antibody seroconversion for all 10 seroconversion panels tested. A fully automated COBAS AmpliScreen(TM)version of this test is being validated. COBAS AmpliScreen tests for HCV and HBV also incorporate the multi-prep specimen processing method, thereby making it possible to use a single processed specimen to screen for all three viruses.  相似文献   

4.

Background

HIV-1 and Hepatitis B and C viruses coinfection is common in Sub-Saharan Africa due to similar routes of transmission and high levels of poverty. Most studies on HIV-1 and Hepatitis B and C viruses have occurred in hospital settings and blood transfusion units. Data on Hepatitis B and C viruses and HIV-1 coinfection in informal urban settlements in Kenya are scanty, yet they could partly explain the disproportionately high morbidity and mortality associated with HIV-1 infections in these slums.

Objectives

The objective of this study was to determine the prevalence of HIV and Hepatitis B and C dual infection in urban slums in Nairobi.

Methods

Blood samples were collected from residents of Viwandani and Korogocho between 2006 and 2007. A structured questionnaire was used to obtain socio-demographic data from participants. Samples were screened for Hepatitis B surface antigen (HBsAg), anti-HCV and anti-HIV-1. Statistical analysis was done using STATA.

Results

Samples were successfully collected from 418 (32%) men and 890 (68%) females. The HIV-1, HBV and HCV prevalence was 20.4%, 13.3% and 0.76% respectively at the time of the study. Of the 268 (20.4%) HIV-1 positive participants, 56 (4.26%) had HBV while 6 (0.46%) had HCV. Of the 1041 HIV-1 negative participants, 117 (8.9%) had HBV while 4 (0.31%) had HCV. Only two people (0.15%) were co-infected with all the three viruses together.

Discussion

The odds of getting hepatitis infection were higher in HIV-1 participants (for HBV OR 2.08,p<0.005 and for HCV OR 5.93, p<0.005). HIV prevalence rates were similar in both informal settlements. HIV infection was highest in age group 35-39 years and among the divorced/separated or widowed. Prevalence of all viruses was highest in those who did not have any formal education.

Conclusion

The HIV prevalence in these informal settlements suggests a higher rate than what is observed nationally. The prevalence rates of HBV are significantly higher in the HIV-1 positive and negative populations. HCV as well as triple HIV-1, HBV and HCV coinfection are uncommon in Korogocho and Viwandani. This clearly indicates the need for HIV-1 control programmes and hepatitis B virus vaccination to be promoted through public awareness as preventive strategy.  相似文献   

5.
目的:建立同时实现乙型肝炎病毒(hepatitisBvirus,HBV)、丙型肝炎病毒(hepatitisCvirus,HCV)、艾滋病病毒(humanImmunodeficiencyVirus,HIV)检测的多重核酸筛查系统。方法:以HBV、HCV、HIV的保守序列为模板设计特异性引物和探针,通过核酸自动提取系统结合一步法RT-PCR技术平台,优化相关反应体系和条件,建立多重多色实时荧光PCR检测血源性传播病毒的核酸筛查系统。将该系统用于101387例血浆样本的筛查。结果:本研究建立的核酸筛查系统特异性好,HBV灵敏度可以达到20IU/ml,HCV灵敏度可以达到100IU/ml,HIV灵敏度可以达到50IU/mL。结论:本研究建立的核酸筛查系统具有高度自动化、高灵敏度、低成本等特点,适合我国血站系统推广使用。  相似文献   

6.
The first nationwide nucleic acid amplification testing (NAT) for hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type 1 (HIV-1) of voluntarily donated blood after serological pre-screening and before release of cellular components and plasma for fractionation was implemented by the Japanese Red Cross Blood Transfusion Services. From February 1, 2000 to April 30, 2001, specimens from 6,805,010 units of serologically negative donation were screened in minipools of 50 samples within 24 hr after blood donation by NAT using multiplex HBV/HCV/HIV-1 reagent for blood transfusion including short shelf-life platelets. Among them, 112 HBV DNA-positives, 25 HCV RNA positives and 4 HIV-1 RNA positives were screened out and we could prevent transfusion of these NAT positive units. Subtypes/genotypes of HBV DNA, adr/C, adw/A, adw/B, adw/C, ayr/C and ayw/D were found and adr/C was predominant. A total of 61.6 % of them (69/112) were negative by overnight EIA. Sixth three of HBV NAT-positive samples carried virus loads less than 10(4) copies/mL and 92.1 % of them (58/63) were negative by overnight EIA. The virus growth curves of HBV in 6 cases obtained by retrospective and prospective follow-up study showed exponential straight lines in the early stage of serological window periods and the log times of HBV growth (10 fold increase) in serological window period were between 4.6 and 7.6 days. NAT screening with highly sensitive reagents in pool of specimens is useful to exclude blood units with low level of HBV and HBV mutants from blood transfusion.  相似文献   

7.
At least 10 million individuals worldwide are co-infected with immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV). These two viruses are transmitted most primarily by exposure to infected blood or blood products. Various nucleic acid assays have been developed for diagnostics and therapeutic monitoring of infections. In the present study, a multiplex real-time PCR assay for simultaneous detection of HCV and HIV-1 using molecular beacons were designed and validated. A well-conserved region in the HIV-1 pol gene and 5′NCR of HCV genome were used for primers and molecular beacon design. The analysis of scalar concentrations of the samples indicated that this multiplex procedure detects at least 1,000 copies/ml of HIV-1 and 100 copies/ml of HCV with linear reference curve (R 2 > 0.94). The results demonstrate that a specificity of 100 % and sensitivity of 96 % can be achieved. The analytical sensitivity study with BLAST software demonstrated that the primers do not attach to any other sequences except for that of HIV-1 or HCV. The primers and molecular beacon probes only detected HIV-1 and all major variants of HCV. This assay may represent an alternative rapid and relatively inexpensive screening method for detection of HIV-1/HCV co-infection especially in blood screening.  相似文献   

8.
N Pripuzova  R Wang  S Tsai  B Li  GC Hung  RG Ptak  SC Lo 《PloS one》2012,7(8):e43246

Background

Real-time PCR array for rapid detection of multiple viral pathogens should be highly useful in cases where the sample volume and the time of testing are limited, i.e. in the eligibility testing of tissue and organ donors.

Findings

We developed a real-time PCR array capable of simultaneously detecting eight human viral pathogens: human immunodeficiency virus types 1 and 2 (HIV-1 and -2), hepatitis B virus (HBV), hepatitis C virus (HCV), human T-cell leukemia virus-1 and -2 (HTLV-1 and -2), vaccinia virus (VACV) and West Nile virus (WNV). One hundred twenty (120) primers were designed using a combination of bioinformatics approaches, and, after experimental testing, 24 primer sets targeting eight viral pathogens were selected to set up the array with SYBR Green chemistry. The specificity and sensitivity of the virus-specific primer sets selected for the array were evaluated using analytical panels with known amounts of viruses spiked into human plasma. The array detected: 10 genome equivalents (geq)/ml of HIV-2 and HCV, 50 geq of HIV-1 (subtype B), HBV (genotype A) and WNV. It detected 100–1,000 geq/ml of plasma of HIV-1 subtypes (A – G), group N and CRF (AE and AG) isolates. Further evaluation with a panel consisting of 28 HIV-1 and HIV-2 clinical isolates revealed no cross-reactivity of HIV-1 or HIV-2 specific primers with another type of HIV. All 28 viral isolates were identified with specific primer sets targeting the most conserved genome areas. The PCR array correctly identified viral infections in a panel of 17 previously quantified clinical plasma samples positive for HIV-1, HCV or HBV at as low as several geq per PCR reaction.

Conclusions

The viral array described here demonstrated adequate performance in the testing of donors’ clinical samples. Further improvement in its sensitivity for the broad spectrum of HIV-1 subtypes is under development.  相似文献   

9.
A survey was conducted in the hemodialysis population of the state of Tocantins, Brazil, aiming to assess the prevalence of hepatitis B virus (HBV) and hepatitis C virus (HCV) infections, to analyze associated risk factors, and also to investigate these viruses genotypes distribution. During January and March 2001, all patients (n = 100) were interviewed at the unique dialysis unit in Tocantins. Blood samples were collected and serum samples were screened for HBV serological markers. Hepatitis B surface antigen positive samples were tested for HBV DNA. All samples were also tested for anti-HCV antibodies and HCV RNA. An overall prevalence of 45% was found for HBV infection (4% were HBsAg/anti-HBc positive, 2% were anti-HBc only and 39% had anti-HBc/anti-HBs markers). Concerning HCV infection, anti-HCV and HCV RNA were detected in 13% and 14% of the subjects, respectively. Three patients were HCV RNA positive and anti-HCV negative, resulting in an overall HCV prevalence of 16%. Univariate analysis of risk factors showed that only shift and length of tile on hemodialysis were associated with HBV and HCV positivity respectively. Among the four HBsAg-positive samples, HBV DNA was detected in three of them, which were identified as genotype A by restriction fragment length polymorphism (RFLP) analysis. All 14HCV RNA-positive samples were genotyped by INNO-LiPA. Genotypes la and 3a were found in 85% and 15%, respectively. The present data show low HBsAg and HCV prevalence rates. The risk factors associated with HBV and HCV positivity suggest that nosocomial transmission may influence in spreading these viruses in the dialysis unit studied.  相似文献   

10.
MethodsThe performance of DBS in HBV quantification was investigated using a modified commercial test (Abbott RealTime HBV assay). Paired DBS and plasma samples were collected from an HBV positive cohort in Addis Ababa, Ethiopia. DBS were stored at ambient temperature for 4–39 days before shipment to the laboratory.ResultsTwenty-six paired samples were selected covering the total range of quantification, from 2.14 log IU/ml to >7 log IU/ml. HBV was detected in 21 of 21 (100%) DBS from patients with a corresponding plasma viral load above 2.70 log IU/ml. The mean difference between plasma and DBS was 0.59 log IU/ml, and the correlation was strong (R2 = 0.92). In stability studies there was no significant change in DBS viral load after storage at room temperature for up to 12 weeks.ConclusionsThis study suggests that DBS can be a feasible and reliable alternative to plasma for quantification of HBV in resource-limited settings. DBS can expand access to antiviral treatment for patients in low- and middle-income countries.  相似文献   

11.
A novel multiplex real-time PCR assay for concurrent detection of hepatitis viruses was evaluated for its clinical performance in screening patients with acute hepatitis. A total of 648 serum samples were collected from patients with acute symptoms of hepatitis. Concurrent detection of nucleic acids of HAV, HBV and HCV was performed using the Magicplex™ HepaTrio Real-time Detection test. Serum nucleic acid levels of HBV and HCV were also quantified by the Cobas® AmpliPrep/Cobas® TaqMan® (CAP/CTM) HBV and HCV tests. Patients’ medical records were also reviewed. Concordance rates between the results from the HepaTrio and the CAP/CTM tests for the detection of HBV and HCV were 94.9% (k = 0.88) and 99.2% (k = 0.98), respectively. The cycle threshold values with the HepaTrio test were also correlated well with the levels of HBV DNA (r = −0.9230) and HCV RNA (r = −0.8458). The sensitivity and specificity of the HepaTrio test were 93.8% and 98.2%, respectively, for detecting HBV infection, and 99.1% and 100.0%, respectively, for HCV infection. For the HepaTrio test, 21 (3.2%) cases were positive for both HBV and HCV. Among the positive cases, 6 (0.9%) were true coinfections. This test also detected 18 (2.8%) HAV positives. The HepaTrio test demonstrated good clinical performance and produced results that agreed well with those of the CAP/CTM assays, especially for the detection of HCV. This assay was also able to detect HAV RNA from anti-HAV IgM-positive individuals. Therefore, this new multiplex PCR assay could be useful for the concurrent detection of the three hepatitis viruses.  相似文献   

12.
Intravenous drug users are frequently exposed to parenterally transmitted viral infections, and these infections can spread to the general population through sexual activity. We investigated the prevalence of serologic markers for human immunodeficiency virus type 1 (HIV-1), human T-cell lymphotropic virus type I/II (HTLV-I/II), hepatitis B virus (HBV), and hepatitis C virus (HCV) in intravenous drug users and their sexual contacts. Of 585 drug users from northern California tested for these serologic markers, 72% were reactive for the antibody to HCV, 71% for the antibody to hepatitis B core antigen, 12% for HTLV-I/II antibodies, and 1% for the HIV-1 antibody. The prevalence of serologic markers for these four viruses correlated with the duration of intravenous drug use, the ethnic group, and the drug of choice. More than 85% of subjects infected with either HCV or HBV were coinfected with the other virus. All persons reactive to HTLV-I/II antibodies had antibodies for either HBV or HCV. Of 81 sexual contacts tested, 17% had evidence of HBV infection while only 6% were reactive for HTLV-I/II antibodies and 4% for the antibody to HCV. None of this group was infected with HIV-1. We conclude that HTLV-I/II and HCV are inefficiently transmitted to sexual contacts while HBV is spread more readily. Programs designed to discourage the sharing of drug paraphernalia, such as needle and syringe exchanges, should decrease the risk of parenterally spread viral infections in intravenous drug users and thus slow the spread of these infections to the general population.  相似文献   

13.
We set out to determine the seroprevalence of hepatitis B and C among human immunodeficiency virus type-1 (HIV-1) infected individuals in North-Central Nigeria to define the influence of these infections on CD4+ lymphocytes cells among our patients as access to antiretroviral therapy improves across the Nigerian nation. The CD4+ values of 180 confirmed HIV-1 infected individuals were enumerated using a superior fluorescence-activated cell sorter system. These patients were tested for the presence of hepatitis B surface antigen and anti-hepatitis C virus (HCV) using third generation enzyme-linked immunosorbent assays. Fifty (27.8%) patients had active hepatitis B virus (HBV) infection while 33 (18.3%) tested positive for anti-HCV antibody. Of these infections, 110 (61.1%), 37 (20.6%), and 20 (11.1%) had HIV only, HBV/HIV-only, and HCV/HIV-only respectively. A HBV/HCV/HIV coinfection prevalence of 7.2% (13 patients) was recorded. Patients coinfected with HIV/HBV/HCV appeared to have lower CD4+ counts (mean = 107 cells/microl; AIDS defining) when compared to HBV/HIV-only (mean = 377 cells/microl), HCV/HIV-only (mean = 373 cells/microl) and patients with mono HIV infection (mean = 478 cells/microl). Coinfection with HBV or HCV is relatively common among HIV-infected patients in Nigeria and should be a big consideration in the initiation and choice of therapy.  相似文献   

14.

Background

Hepatitis B virus (HBV) and hepatitis C virus (HCV) co-infections contributes to a substantial proportion of liver disease worldwide. The aim of this study was to assess the clinical and virological features of HBV-HCV co-infection.

Methods

Demographic data were collected for 3238 high-risk people from an HCV-endemic region in China. Laboratory tests included HCV antibody and HBV serological markers, liver function tests, and routine blood analysis. Anti-HCV positive samples were analyzed for HCV RNA levels and subgenotypes. HBsAg-positive samples were tested for HBV DNA.

Results

A total of 1468 patients had chronic HCV and/or HBV infections. Among them, 1200 individuals were classified as HCV mono-infected, 161 were classified as HBV mono-infected, and 107 were classified as co-infected. The HBV-HCV co-infected patients not only had a lower HBV DNA positive rate compared to HBV mono-infected patients (84.1% versus 94.4%, respectively; P<0.001). The median HCV RNA levels in HBV-HCV co-infected patients were significantly lower than those in the HCV mono-infected patients (1.18[Interquartile range (IQR) 0–5.57] versus 5.87[IQR, 3.54–6.71] Log10 IU/mL, respectively; P<0.001). Furthermore, co-infected patients were less likely to have detectable HCV RNA levels than HCV mono-infected patients (23.4% versus 56.5%, respectively; P<0.001). Those HBV-HCV co-infected patients had significantly lower median HBV DNA levels than those mono-infected with HBV (1.97[IQR, 1.3–3.43] versus 3.06[IQR, 2–4.28] Log10 IU/mL, respectively; P<0.001). The HBV-HCV co-infection group had higher ALT, AST, ALP, GGT, APRI and FIB-4 levels, but lower ALB and total platelet compared to the HBV mono-infection group, and similar to that of the HCV mono-infected group.

Conclusion

These results suggest that co-infection with HCV and HBV inhibits the replication of both viruses. The serologic results of HBV-HCV co-infection in patients suggests more liver injury compared to HBV mono-infected patients, but is similar to HCV mono-infection.  相似文献   

15.
应用ELISA和PCR法检测502例乙肝病人血清,401例HBsAg阳性血清中,有114例(28.4%)抗-HCV和HCVRNA双项阳性,25例(6.2%)HCVRNA单项阳性;21例(5.2%)抗-HCV单项阳性。将HBsAg乙肝病人分成HBVDNA,HBeAg阳性组和HBVDNA,HBeAg阴性组。前者抗-HCV阳性率为11.6%~20.5%,HCVRNA阳性率为16.2%~20.5%。后者抗-HCV阳性率为20.2%~55.6%,HCVRNA阳性率为23%~60.3%。结果说明长期携带HBV者和慢性乙肝病人均可重叠HCV感染。HBVDNA阳性组抗-HCV和HCVRNA阳性率明显高于HBVDNA阳性组  相似文献   

16.
探讨研制能同时检测HBV、HCV、HIV、HAV、GBV-C/HGV和B19的微阵列监控芯片。根据病毒公开发表序列,序列比对,得出保守区域,设计病毒的特异性检测探针,同时设置阴性、阳性参照探针,制备监控微阵列。利用随机引物PCR方法标记样品中的病毒靶序列,标记产物与微阵列上的探针杂交,清洗、扫描后进行结果分析。通过对质粒或模式分子的检测以及经HBV、HCV、HIV临床标本的验证,发现该微阵列监控芯片具有良好的特异性。其对质粒的检测灵敏度可达102病毒拷贝数,对临床标本的检测灵敏度可达103病毒拷贝数。此外,该微阵列监控芯片可检测出病毒混合感染血清。为微阵列监控芯片应用于此六种血液病毒的检测打下一定的基础。  相似文献   

17.

Background

Men who have sex with men (MSM) are more vulnerable to blood-borne infections and/or sexually-transmitted infections (STI). This study was conducted to estimate the prevalences of mono and co-infections of HIV-1 and other blood-borne/STIs in a sample of MSM in Campinas, Brazil.

Methods

Responding Driven Sampling (RDS) was used for recruitment of MSM. Serum samples collected from 558 MSM were analyzed for the presence of serological markers for HIV-1, HBV, HCV, HTLV, HPV-16/18, and T. pallidum infections.

Results

The highest prevalences of infection in serum samples were found for HPV-16 and 18 (31.9% and 20.3%, respectively). Approximately 8% of the study population showed infection with HIV-1, and within that group, 27.5% had recently become infected with HIV-1. HBV infection and syphilis were detected in 11.4% and 10% of the study population, respectively, and the rates of HTLV and HCV infection were 1.5% and 1%, respectively. With the exception of HTLV, all other studied infections were usually found as co-infections rather then mono-infections. The rates of co-infection for HCV, HPV-18, and HIV-1 were the highest among the studied infections (100%, 83%, and 85%, respectively). Interestingly, HTLV infection was usually found as a mono-infection in the study group, whereas HCV was found only as a co-infection.

Conclusions

The present findings highlight the need to educate the MSM population concerning their risk for STIs infections and methods of prevention. Campaigns to encourage vaccination against HBV and HPV could decrease the rates of these infections in MSM.  相似文献   

18.
19.
Acute and chronic viral hepatitis infections are corresponding to increase the risk of different types of hematological malignancies especially with leukemia. In this study the serological and molecular markers of hepatitis viruses were evaluated in patients with different types of leukemia in comparing with control group. In this cross sectional study, 100 EDTA-treated blood samples were collected from leukemia patients and also from healthy control group, respectively. Serological and molecular markers of HBV, HCV and HDV viruses were analyzed for determination of the role of these hepatitis viruses in clinical outcomes of leukemia disorders. Increasing risk factors of leukemia were evaluated statistically in two studied groups by SPSS software. One of molecular and immunological markers of HBV, HDV and HCV was found in 24 of 100 (24%), 22 of 100 (22%), and 1 of 100 (1%) patients with leukemia and in 12 of 100 (12%), 6 of 100 (6%), and 2 of 100 (2%) control patients. Significant differences were detected in detection of HBsAg (P = 0.02), HBeAb (P = 0.009), and HCV-RNA (P = 0.05) between leukemia patients and control group, respectively. The high prevalence of HBV and HCV infective markers were detected in ALL and AML patients. Identification of high prevalence of HBV and HCV infective markers in leukemia patients proposed strong association between hepatitis viral infections and leukemia. Therefore, evaluation of the prevalence of viral hepatitis infections in larger groups of patients with long lasting follow up is suggesting.  相似文献   

20.
BACKGROUND: Previous epidemiological studies of rural human populations in Gabon reveal a high prevalence of human hepatitis A, B, C and D viruses. In order to investigate the prevalence of the blood-born hepatitis viruses in apes and monkeys living in the same area, we performed an epidemiological survey of HBV, HCV and HDV in wild-born non-human primates. METHODS: We tested 441 wild-born non-human primates from Gabon and Congo and 132 imported monkeys for the presence of serological markers of HBV, HCV and HDV infections. RESULTS: None of Cercopithecidae monkeys were reactive against HBV/HDV and HCV. In contrast, 29.2% of wild-born great apes (154 chimpanzees and 14 gorillas) were positive for HBV serological markers. Nine chimpanzees were in the replicative phase of HBV infection. None of these HBV infected chimpanzees exhibited symptoms or significant changes in serum clinical chemistry related to HBV infection. CONCLUSIONS: The negativity to HCV-related viruses and the negativity of the Cercopithecidae species tested against HBV/HDV do not allow us to definitively rule out the presence of an animal counterpart of human hepatitis viruses in non-human primates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号