首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
The microbial dynamics associated with granular activated carbon (GAC) in a pilot water treatment plant were investigated over a period of 16 months. Microbial populations were monitored in the influent and effluent waters and on the GAC particles by means of total plate counts and ATP assays. Microbial populations between the influent and effluent waters of the GAC columns generally increased, indicating microbial growth. The dominant genera of microorganisms isolated from interstitial waters and GAC particles were Achromobacter, Acinetobacter, Aeromonas, Alcaligenes, Bacillus, Chromobacterium, Corynebacterium, Micrococcus, Microcyclus, Paracoccus, and Pseudomonas. Coliform bacteria were found in small numbers in the effluents from some of the GAC columns in the later months of the study. Oxidation of influent waters with ozone and maintenance of aerobic conditions on the GAC columns failed to appreciably enhance the microbial growth on GAC.  相似文献   

2.
The microbial dynamics associated with granular activated carbon (GAC) in a pilot water treatment plant were investigated over a period of 16 months. Microbial populations were monitored in the influent and effluent waters and on the GAC particles by means of total plate counts and ATP assays. Microbial populations between the influent and effluent waters of the GAC columns generally increased, indicating microbial growth. The dominant genera of microorganisms isolated from interstitial waters and GAC particles were Achromobacter, Acinetobacter, Aeromonas, Alcaligenes, Bacillus, Chromobacterium, Corynebacterium, Micrococcus, Microcyclus, Paracoccus, and Pseudomonas. Coliform bacteria were found in small numbers in the effluents from some of the GAC columns in the later months of the study. Oxidation of influent waters with ozone and maintenance of aerobic conditions on the GAC columns failed to appreciably enhance the microbial growth on GAC.  相似文献   

3.
The complex ecology of free-living amoebae (FLA) and their role in spreading pathogenic microorganisms through water systems have recently raised considerable interest. In this study, we investigated the presence of FLA and amoebae-resisting bacteria (ARB) at various stages of a drinking water plant fed with river water. We isolated various amoebal species from the river and from several points within the plant, mostly at early steps of water treatment. Echinamoeba- and Hartmannella-related amoebae were mainly recovered in the drinking water plant whereas Acanthamoeba- and Naegleria-related amoebae were recovered from the river water and the sand filtration units. Some FLA isolates were recovered immediately after the ozonation step, thus suggesting resistance of these microorganisms to this disinfection procedure. A bacterial isolate related to Mycobacterium mucogenicum was recovered from an Echinamoeba-related amoeba isolated from ozone-treated water. Various other ARB were recovered using co-culture with axenic Acanthamoeba castellanii, including mycobacteria, legionella, Chlamydia-like organisms and various proteobacteria. Noteworthy, a new Parachlamydia acanthamoebae strain was recovered from river water and from granular activated carbon (GAC) biofilm. As amoebae mainly multiply in sand and GAC filters, optimization of filter backwash procedures probably offers a possibility to better control these protists and the risk associated with their intracellular hosts.  相似文献   

4.
Biofilters of granular activated carbon (GAC) are responsible for the removal of organic matters in drinking water treatments. PreBiofilters, which operate as the first unit in a surface water treatment train, are a cost-effective pretreatment for conventional surface water treatment and provide more consistent downstream water quality. This study investigated bacterial communities from the samples of raw surface water, biofilm on the PreBiofilter, and filtrates for surface water pretreatment. A bench-scale pilot plant of PreBiofilter was constructed to pretreat surface water from the Canoochee River, GA, USA. PreBiofilter exhibited a significant reduction of total organic carbon and dissolved organic carbon. The evenness and Shannon diversity of bacterial operational taxonomic units (OTUs) were significantly higher on the biofilm of PreBiofilter than in raw water and filtrates. Similar bacteria communities were observed in the raw water and filtrates using relative abundance of bacterial OTUs. However, the bacterial communities in the filtrates became relatively similar to those in the biofilm using presence/absence of bacterial OTUs. GAC biofilm or raw water and filtrates greatly contributed to the abundance of bacteria; whereas, bacteria sheared from colonized biofilm and entered filtrates. Evenly distributed, diverse and unique bacteria in the biofilm played an important role to remove organic matters from surface water for conventional surface water pretreatment.  相似文献   

5.
We examined the variations of bacterial populations in treated drinking water prior to and after the final chlorine disinfection step at two different surface water treatment plants. For this purpose, the bacterial communities present in treated water were sampled after granular activated carbon (GAC) filtration and chlorine disinfection from two drinking water treatment plants supplying the city of Paris (France). Samples were analyzed after genomic DNA extraction, polymerase chain reaction (PCR) amplification, cloning, and sequencing of a number of 16S ribosomal RNA (rRNA) genes. The 16S rDNA sequences were clustered into operational taxonomic units (OTUs) and the OTU abundance patterns were obtained for each sample. The observed differences suggest that the chlorine disinfection step markedly affects the bacterial community structure and composition present in GAC water. Members of the Alphaproteobacteria and Betaproteobacteria were found to be predominant in the GAC water samples after phylogenetic analyses of the OTUs. Following the chlorine disinfection step, numerous changes were observed, including decreased representation of Proteobacteria phylotypes. Our results indicate that the use of molecular methods to investigate changes in the abundance of certain bacterial groups following chlorine-based disinfection will aid in further understanding the bacterial ecology of drinking water treatment plants (DWTPs), particularly the disinfection step, as it constitutes the final barrier before drinking water distribution to the consumer’s tap.  相似文献   

6.
Aim:  Identification of the predominating cultivable bacteria in granular activated carbon (GAC) filters used in a variety of water treatment plants for selecting representative strains to study the role of bacteria in the removal of dissolved organic matter.
Methods and Results:  Bacterial isolates were collected from 21 GAC filters in nine water treatment plants treating either ground water or surface water with or without oxidative pretreatment. Enrichment of samples in dilute liquid medium improved culturability of the bacteria by approximately log unit, to 9% up to 70% of the total cell counts. Genomic fingerprinting and 16S rDNA sequence analysis revealed that most (68%) of the isolates belonged to the Betaproteobacteria and 25% were identified as Alphaproteobacteria . The number of different genera within the Betaproteobacteria was higher in the GAC filters treating ozonated water than in the filters treating nonozonated water. Polaromonas was observed in nearly all of the GAC filters (86%), and the genera Hydrogenophaga , Sphingomonas and Afipia were observed in 43%, 33% and 29% of the filter beds, respectively. AFLP analysis revealed that the predominating genus Polaromonas included a total of 23 different genotypes.
Conclusions:  This study is the first to demonstrate that Polaromonas , which has mainly been observed in ultraoligotrophic freshwater environments, is a common component of the microbial community in GAC filters used in water treatment.
Significance and Impact of the Study:  The predominance of ultraoligotrophic bacteria in the GAC filters indicates that very low concentrations of substrates are available for microbial growth. Polaromonas species are suited for further studies on the nutritional versatility and growth kinetics enabling the modelling of biodegradation processes in GAC filters.  相似文献   

7.
A total of 3819 bacterial cultures isolated from municipal water samples were identified using a combination of Enterotubules and confirmatory media. Frequency distributions for the different genera or groups of bacteria were similar for raw water and drinking water isolations, except for Escherichia organisms which doubled their frequency in raw water. Differences between the membrane filter (MF) and presence-absence (P-A) test with regard to types of organisms isolated were limited to Klebsiella organisms which were preferentially cultured from MF plates. Members of the genus Enterobacter were isolated more than twice as frequently as any of the other coliform genera dealt with in this study. Aeromonas organisms were detected almost as often as such individual genera as Escherichia, Citrobacter, or Klebsiella. Although non-lactose fermenting colonies (false-negatives) of the coliform genera would not be detected by the MF technique, their lack of detection would likely be offset by the Aeromonas colonies (false-positives). At least 25% of the coliform isolates were either anaerogenic or non-lactose fermenters and would therefore go undetected by the most probably number (MPN) technique.  相似文献   

8.
Microbial biofilms from surfaces in contact with water may play a beneficial role in drinking water treatment as biological filters. However, detrimental effects such as biofouling (i.e., biocorrosion and water quality deterioration) may also occur. In this study microbiological processes and factors influencing the activity of bacteria in biofilms were investigated by conventional cultivation methods. The presence of bacteria belonging to different ecophysiological groups was assessed during drinking water treatment, in biofilms developed on concrete, steel and sand surfaces. Influences of the treatment process, type of immersed material and physico-chemical characteristics of raw/bulk water and biofilms upon the dynamics of bacterial communities were evaluated. Results revealed intense microbial activity in biofilms occurring in the drinking water treatment plant of Cluj. Ammonification, iron reduction and manganese oxidation were found to be the predominant processes. Multiple significant correlations were established between the evolution of biofilm bacteria and the physico-chemical parameters of raw/ bulk water. The type of immersed material proved to have no significant influence upon the evolution of microbial communities, but the treatment stage, suggesting that the processes applied restrict microbial growth not only in bulk fluid but in biofilms, too.  相似文献   

9.
10.
Antibiotic-resistant bacteria in drinking water.   总被引:9,自引:6,他引:3       下载免费PDF全文
We analyzed drinking water from seven communities for multiply antibiotic-resistant (MAR) bacteria (bacteria resistant to two or more antibiotics) and screened the MAR bacterial isolates obtained against five antibiotics by replica plating. Overall, 33.9% of 2,653 standard plate count bacteria from treated drinking waters were MAR. Two different raw water supplies for two communities carried MAR standard plate count bacteria at frequencies of 20.4 and 18.6%, whereas 36.7 and 67.8% of the standard plate count populations from sites within the respective distribution systems were MAR. Isolate identification revealed that MAR gram-positive cocci (Staphylococcus) and MAR gram-negative, nonfermentative rods (Pseudomonas, Alcaligenes, Moraxella-like group M, and Acinetobacter) were more common in drinking waters than in untreated source waters. Site-to-site variations in generic types and differences in the incidences of MAR organisms indicated that shedding of MAR bacteria living in pipelines may have contributed to the MAR populations in tap water. We conclude that the treatment of raw water and its subsequent distribution select for standard plate count bacteria exhibiting the MAR phenotype.  相似文献   

11.
The waste treatment facilities and final effluents of 11 meat-packing plants in the Province of Alberta were investigated primarily to determine the numbers of indicator bacteria and the presence of Salmonella. This was done to discover the efficiency of the treatment systems presently in operation in reducing bacterial numbers and to establish the need for disinfection and for bacterial standards for these effluents. Data obtained showed that the final effluents were of very poor quality bacteriologically, with numbers of indicator organisms comparable to those found in raw sewage. Primary treatment facilities were ineffective in reducing the numbers of these bacteria. The secondary treatment facility investigated achieved greater than a 99% reduction of indicator bacteria. Salmonella were isolated from the final effluents of 78% of the plants, including the plant using secondary treatment. In total, 21 Salmonella serotypes were isolated. Salmonella isolates were not antibiotic resistant, but certain coliform and fecal coliform isolates demonstrated resistance to chloramphenicol, tetracycline, and ampicillin.  相似文献   

12.
Little is known about the bacterial communities associated with the plants inhabiting sand dune ecosystems. In this study, the bacterial populations associated with two major sand dune plant species, Calystegia soldanella (beach morning glory) and Elymus mollis (wild rye), growing along the costal areas in Tae-An, Chungnam Province, were analyzed using a culture-dependent approach. A total of 212 bacteria were isolated from the root and rhizosphere samples of the two plants, and subjected to further analysis. Based on the analysis of the 16S rDNA sequences, all the bacterial isolates were classified into six major phyla of the domain Bacteria. Significant differences were observed between the two plant species, and also between the rhizospheric and root endophytic communities. The isolates from the rhizosphere of the two plant species were assigned to 27 different established genera, and the root endophytic bacteria were assigned to 21. Members of the phylum Gammaproteobacteria, notably the Pseudomonas species, comprised the majority of both the rhizospheric and endophytic bacteria, followed by members of Bacteroidetes and Firmicutes in the rhizosphere and Alphaproteobacteria and Bacteroidetes in the root. A number of isolates were recognized as potentially novel bacterial taxa. Fifteen out of 27 bacterial genera were commonly found in the rhizosphere of both plants, which was comparable to 3 out of 21 common genera in the root, implying the host specificity for endophytic populations. This study of the diversity of culturable rhizospheric and endophytic bacteria has provided the basis for further investigation aimed at the selection of microbes for the facilitation of plant growth.  相似文献   

13.
The development of bacterial communities in drinking water distribution systems leads to a food chain which supports the growth of macroorganisms incompatible with water quality requirements and esthetics. Nevertheless, very few studies have examined the microbial communities in drinking water distribution systems and their trophic relationships. This study was done to quantify the microbial communities (especially bacteria and protozoa) and obtain direct and indirect proof of protozoan feeding on bacteria in two distribution networks, one of GAC water (i.e., water filtered on granular activated carbon) and the other of nanofiltered water. The nanofiltered water-supplied network contained no organisms larger than bacteria, either in the water phase (on average, 5 × 107 bacterial cells liter−1) or in the biofilm (on average, 7 × 106 bacterial cells cm−2). No protozoa were detected in the whole nanofiltered water-supplied network (water plus biofilm). In contrast, the GAC water-supplied network contained bacteria (on average, 3 × 108 cells liter−1 in water and 4 × 107 cells cm−2 in biofilm) and protozoa (on average, 105 cells liter−1 in water and 103 cells cm−2 in biofilm). The water contained mostly flagellates (93%), ciliates (1.8%), thecamoebae (1.6%), and naked amoebae (1.1%). The biofilm had only ciliates (52%) and thecamoebae (48%). Only the ciliates at the solid-liquid interface of the GAC water-supplied network had a measurable grazing activity in laboratory test (estimated at 2 bacteria per ciliate per h). Protozoan ingestion of bacteria was indirectly shown by adding Escherichia coli to the experimental distribution systems. Unexpectedly, E. coli was lost from the GAC water-supplied network more rapidly than from the nanofiltered water-supplied network, perhaps because of the grazing activity of protozoa in GAC water but not in nanofiltered water. Thus, the GAC water-supplied network contained a functional ecosystem with well-established and structured microbial communities, while the nanofiltered water-supplied system did not. The presence of protozoa in drinking water distribution systems must not be neglected because these populations may regulate the autochthonous and allochthonous bacterial populations.  相似文献   

14.
Structure of bacterial communities in diverse freshwater habitats   总被引:1,自引:0,他引:1  
The structures and dynamics of bacterial communities from raw source water, groundwater, and drinking water before and after filtration were studied in four seasons of a year, with culture-independent methods. Genomic DNA from water samples was analyzed by the polymerase chain reaction?- denaturing gradient gel electrophoresis system and by cloning of the 16S rRNA gene. Water samples exhibited complex denaturing gradient gel electrophoresis genetic profiles composed of many bands, corresponding to a great variety of bacterial taxa. The bacterial communities of different seasons from the four sampling sites clustered into two major groups: (i) water before and after filtration, and (ii) source water and groundwater. Phylogenetic analyses of the clones from the autumn sampling revealed 13 phyla, 19 classes, and 155 operational taxonomic units. Of the clones, 66% showed less than 97% similarities to known bacterial species. Representatives of the phyla Proteobacteria, Bacteroidetes, and Actinobacteria were found at all four sampling sites. Species belonging to the phylum Firmicutes were an important component of the microbial community in filtered water. Representatives of Enterobacteriaceae were not detected, indicating the absence of fecal pollution in the drinking water. Differences were found in the bacterial populations that were sampled from the same sites in different seasons. Each water habitat had a unique bacterial profile. Drinking water harbors diverse and dynamic microbial communities, part of which may be active and resilient to chlorine disinfection. This study provides, for the first time, basic data for uncultivable drinking water bacteria in Israel.  相似文献   

15.
The occurrence of Aeromonas spp. and hygienic indicator organisms in raw and treated waters of five drinking water production plants in Flanders (Belgium) was surveyed over a period of 17 months. Aeromonads were isolated on ampicillin-dextrin agar (ADA) and further identified by gas-liquid chromatographic analysis of their cellular fatty acid methyl ester (FAME) content. ADA medium was found to be highly specific for the enumeration of Aeromonas spp. In general, Aeromonas counts were very low in untreated groundwater but numbered 104–106 colony-forming units per liter in open storage reservoirs for surface water. Aeromonas spp. were seasonally distributed with maximal densities occurring during the summer. The ecology of Aeromonas in the different waters was studied in relation to the physical, chemical, and microbiological water characteristics. Strongly positive correlations were observed between Aeromonas densities and heterotrophic plate counts, whereas a clearly negative relationship was found with dissolved oxygen. On average, 99.7% of the aeromonads were removed by flocculation-decantation followed by breakpoint chlorination, whereas 98.9% were removed by slow sand filtration. Flocculation-decantation without breakpoint chlorination did not reduce the microbial numbers. At three of four drinking water production plants tested, rapid sand filtration decreased the number of aeromonads and hygienic indicator organisms. At one plant, however, the numbers of Aeromonas and hygienic indicator organisms were high in the sand filter effluents. Increased numbers of aeromonads were also counted in the effluent of the activated carbon filters. Hence, inactivation of Aeromonas spp. by the current process technology appears not sufficient to exclude postchlorination. The survival of aeromonads in certain filter systems may be due to the growth of these bacteria on biodegradable organic material, provided by the decomposition from bacteria, algae, or other sources. Correspondence to: W. Verstraete  相似文献   

16.
Post treatment of effluents from heterotrophic groundwater denitrification fluidized bed reactors (FBR) designed to achieve drinking water quality has been investigated. The denitrification process adds to the dissolved organic compounds, biomass and bacteria in the effluent. They are also lacking dissolved oxygen. Effluents from the process were treated in combined post treatment processes based on either a trickling filter and sedimentation unit (‘TF combination’) or contact flocculation (‘CF combination’). Both processes were followed by sand filtration, granular activated carbon (GAC) and chlorination. Results regarding total suspended solids (TSS) and turbidity removal showed an advantage to the ‘CF combination’, and the target turbidity (NTU <1) was always achieved when the alum dose was 10 or 20 mg l−1. Backwash of the sand filter and GAC column was required after 27 h of operation (average value). An average total reduction in dissolved organic carbon (DOC) of 40% was observed with a final DOC of 3.5–4 mg L−1. Most of the removal of the DOC occurred in the sand filter (28%), while the GAC contribution was smaller (18%). No regrowth potential was observed using the Werner method when a pure culture of Pseudomonas fluorescens P17 was used as inoculum in samples of chlorinated effluent (post chlorination). When a mixed culture of indigenous bacteria was used as inoculum, a high regrowth potential was observed. Installing an additional chlorination unit before the sand filter column (pre and post chlorination) resulted in effluent with no regrowth potential for both Pseudomonas fluorescens P17 and indigenous bacteria. Received 17 October 1997/ Accepted in revised form 29 May 1998  相似文献   

17.
The water quality of 24 rural, domestic groundwater supplies treated with point-of-use, powdered activated carbon (PAC) filters was monitored to determine how such treatment might impact the bacteriological quality of private, residential drinking water supplies. Heterotrophic-plate-count (HPC) and total coliform analyses were performed on raw, PAC-treated, and overnight or stagnant (first-draw) PAC-treated water samples. Densities of HPC bacteria were elevated by 0.86 and 0.20 orders of magnitude for spring and well water systems, respectively, in PAC-treated effluents following overnight stagnation compared with levels in untreated treated effluents. Densities of HPC bacteria in PAC-treated effluents were significantly reduced (P < 0.01) below influent levels, however, after the point-of-use device was flushed for 2 min. While PAC significantly reduced the number of coliforms in product waters (P < 0.01), these indicator organisms were still detected in some effluents. Seasonal variations were evident in microbial counts from spring but not well water systems. It appears that aside from periods following stagnant-water use, such as overnight, PAC treatment does not compromise the bacteriological quality of drinking water obtained from underground sources.  相似文献   

18.
Bacteriological analyses were performed on the effluent from a conventional water treatment pilot plant in which granular activated carbon (GAC) had been used as the final process to assess the impact of GAC on the microbial quality of the water produced. Samples were collected twice weekly for 160 days from the effluents of six GAC columns, each of which used one of four different empty-bed contact times (7.5, 15, 30, and 60 min). The samples were analyzed for heterotrophic plate counts and total coliforms. Effluent samples were also exposed to chloramines and free chlorine for 60 min (pH 8.2, 23 degrees C). Bacterial identifications were performed on the disinfected and nondisinfected effluents. Additional studies were conducted to assess the bacteriological activity associated with released GAC particles. The results indicated that heterotrophic plate counts in the effluents from all columns increased to 10(5) CFU/ml within 5 days and subsequently stabilized at 10(4) CFU/ml. The heterotrophic plate counts did not differ at different empty-bed contact times. Coliforms (identified as Enterobacter spp.) were recovered from the nondisinfected effluent on only two occasions. The disinfection results indicated that 1.5 mg of chloramines per liter inactivated approximately 50% more bacteria than did 1.0 mg of free chlorine per liter after 1 h of contact time. Chloramines and chlorine selected for the development of different bacterial species--Pseudomonas spp. and Flavobacterium spp., respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
Eight waterworks in The Netherlands, which use surface water as their raw water source, were sampled repeatedly between November 1978 and June 1981. At five waterworks , 30 of 45 samples of raw water contained viruses. Of 55 samples of partially purified water, 11 were virus positive, including 8 after coagulation, sedimentation, and rapid sand filtration, 2 after storage, coagulation, sedimentation, transport chlorination, and rapid sand filtration, and 1 after storage in open reservoirs for 5 months. No viruses were detected in 100 samples of drinking water of 500 liters each from six waterworks . Most isolated viruses were typed, and a great variety of human enteroviruses were found, reflecting both pollution of raw water sources with sewage and vaccination with oral polio vaccine in neighboring countries.  相似文献   

20.
Municipal water samples were analyzed by membrane filter (MF) and presence-absence (P-A) tests for pollution indicator bacteria. In four years, 11 514 bacterial cultures were isolated from either raw water, drinking water, or new main water samples submitted to three environmental laboratories. The bacterial species occurring most often in all types of water samples were Escherichia coli (11.6-39.7%), Enterobacter aerogenes (18.1-26.3%), Aeromonas hydrophila (8.8-17.0%), Klebsiella pneumoniae (7.7-10.3%), and Citrobacter freundii (5.9-22.7%). A lactose - lauryl tryptose - tryptone broth was examined as an alternative medium to modified MacConkey broth in the presumptive portion of the P-A test. The intensity of acid and gas production in presumptive positive P-A bottles was compared with the types and frequencies of indicator bacteria shown by confirmatory tests. The results of detecting indicator bacteria following the analysis of 53 130 samples over a 2-year period were arranged by water source (well, lake, river, mixed) and water type (raw or drinking) to determine the influence of these parameters on the recovery of indicator bacteria. A further subdivision of the sample types into raw surface, raw ground, in-plant, plant discharge, reservoir, and distribution samples demonstrated the effect of water treatment practices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号