首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Glycerophosphocholines (GPCho's) are known to cause liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) matrix ionization effects during the analysis of biological samples (i.e. blood, plasma). We have developed a convenient new method, which we refer to as "in-source multiple reaction monitoring" (IS-MRM), for detecting GPCho's during LC-MS/MS method development. The approach uses high energy in-source collisionally induced dissociation (CID) to yield trimethylammonium-ethyl phosphate ions (m/z 184), which are formed from mono- and disubstituted GPCho's. The resulting ion is selected by the first quadrupole (Q1), passed through the collision cell (Q2) in the presence of collision gas at low energy to minimize fragmentation, and m/z 184 selected by the third quadrupole. This approach can be combined with standard multiple reaction monitoring (MRM) transitions with little compromise in sensitivity during method development and sample analysis. Hence, this approach was used to probe ionization matrix effects in plasma samples. The resulting information was employed to develop LC-MS/MS analyses for drugs and their metabolites with cycle times less than 5 min.  相似文献   

2.
A highly sensitive method for quantitation of tamsulosin in human plasma using 1-(2,6-dimethyl-3-hydroxylphenoxy)-2-(3,4-methoxyphenylethylamino)-propane hydrochloride as the internal standard (I.S.) was established using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). After alkalization with saturated sodium bicarbonate, plasma were extracted by ethyl acetate and separated by HPLC on a C18 reversed-phase column using a mobile phase of methanol-water-acetic acid-triethylamine (620:380:1.5:1.5, v/v). Analytes were quantitated using positive electrospray ionization in a quadrupole spectrometer. LC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at m/z 228 for tamsulosin and m/z 222 for the I.S. Calibration curves, which were linear over the range 0.2-30 ng/ml, were analyzed contemporaneously with each batch of samples, along with low (0.5 ng/ml), medium (3 ng/ml) and high (30 ng/ml) quality control samples. The intra- and inter-assay variability ranged from 2.14 to 8.87% for the low, medium and high quality control samples. The extraction recovery of tamsulosin from plasma was in the range of 84.2-94.5%. The method has been used successfully to study tamsulosin pharmacokinetics in adult humans.  相似文献   

3.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for simultaneous quantification of venlafaxine (VEN) and O-desmethyl venlafaxine (ODV) in human plasma. The analytes were extracted from human plasma by using solid-phase extraction (SPE) technique. Escitalopram (ESC) was used as the internal standard. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair has been followed as m/z 278.27-->121.11 for VEN, m/z 264.28-->107.10 for ODV and m/z 325.00-->262.00 for ESC. The method involves a solid phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection at nanogram levels. The proposed method has been validated with linear range of 3-300 ng/ml for VEN and 6-600 ng/ml for ODV. The intrarun and interrun precision and accuracy values are within 10%. The overall recoveries for VEN and ODV were 95.9 and 81.7%, respectively. Total elution time as low as 3 min only.  相似文献   

4.
A selective and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (ESI-MS/MS) method for simultaneous determination of metformin and rosiglitazone in human plasma using phenformin as internal standard (IS) has been first developed and validated. Plasma samples were precipitated by acetonitrile and the analytes were separated on a prepacked Phenomenex Luna 5u CN 100A (150 mm x 2.0 mm I.D.) column using a mobile phase comprised of methanol:30 mM ammonium acetate pH 5.0 (80:20, v/v) delivered at 0.2 ml/min. Detection was performed on a Finnigan TSQ triple-quadrupole tandem mass spectrometer in positive ion selected reaction monitoring (SRM) mode using electrospray ionization. The ion transitions monitored were m/z 130.27-->71.11 for metformin, m/z 358.14-->135.07 for rosiglitazone and m/z 206.20-->105.19 for the IS. The standard curves were linear (r(2)>0.99) over the concentration range of 5-3000 ng/ml for metformin and 1.5-500 ng/ml for rosiglitazone with acceptable accuracy and precision, respectively. The within- and between-batch precisions were less than 15% of the relative standard deviation. The limit of detection (LOD) of both metformin and rosiglitazone was 1 ng/ml. The method described is precise and sensitive and has been successfully applied to the study of pharmacokinetics of compound metformin and rosiglitazone capsules in 12 healthy Chinese volunteers.  相似文献   

5.
A chiral liquid chromatography/mass spectrometry (LC/MS) bioanalytical procedure has been developed for the analysis of the antimalaric agent Fenozan B07 in dog plasma. Normal-phase chromatography involving a phenylcarbamate derivative of cellulose coated on silica gel as the chiral stationary phase was used to resolve (-)-(S,S)-B07 from (+)-(R,R)-B07. The enantiomers were detected by a mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operated in the negative ion mode. A mass spectrum, characterized by a base peak of m/z 285, was obtained for each enantiomer. The m/z 285 ion was very specific for the analysis of both enantiomers in the plasma. The selected ion monitoring analysis of the plasma samples was therefore performed at m/z 285 for quantitative purposes. The enantiomers were extracted from the plasma in a basic medium and purified by solid-phase extraction using a hydrophilic-lipophilic balanced sorbent. A lower limit of quantification of 2 ng/mL in plasma was achieved for both enantiomers. The quantitative procedure reported in this study was highly specific and sensitive, and was validated according to the FDA guidance on bioanalytical method validation.  相似文献   

6.
A sensitive and selective liquid chromatography-tandem spectrometry method for the determination of zolmitriptan was developed and validated over the linearity range 0.05-30 ng/ml with 0.5 ml of plasma using diphenhydramine as the internal standard. Liquid-liquid extraction using a mixture of diethyl ether and dichloromethane was used to extract the drug and the internal standard from plasma. The mass spectrometer was operated under the selected reaction monitoring (SRM) mode using the atmospheric pressure chemical ionization (APCI) technique. The instrument parameters were optimized to obtain 3.0 min run time. The mobile phase consisted of acetonitrile-water-formic acid (70:30:0.5), at a flow rate of 0.5 ml/min. In positive mode, zolmitriptan produced a protonated precursor ion at m/z 288 and a corresponding product ion at m/z 58. And internal standard produced a protonated precursor ion at m/z 256 and a corresponding product ion at m/z 167. The inter- and intra-day precision (%R.S.D.) were less than 8.5% and accuracy (%error) was less than -2.5%. The method had a lower limit of quantification of 0.05 ng/ml for zolmitriptan, which offered increased sensitivity and selectivity of analysis, compared with existing methods. The method was successfully applied to a pharmacokinetic study of zolmitriptan after an oral administration of 5 mg zolmitriptan to 20 healthy volunteers.  相似文献   

7.
Derivatization of 4-hydroxyproline (Hyp) in collagen using trifluoroacetylation and methanol esterification produces two derivatives when analyzed by gas chromatography/mass spectrometry (GC/MS). The diacyl derivative N,O-bis(trifluoroacetyl)-4-hydroxy-L-proline methyl ester (N,O-TFA-Hyp) formed in this manner has a shorter retention time and different fragmentation pattern by GC/MS as compared to the slower eluting monoacetylated species N-trifluoroacetyl-4-hydroxy-L-proline methyl ester (N-TFA-Hyp). By selected ion monitoring of the appropriate ions of either N,O-TFA-Hyp (m/z 164, 278) or N-TFA-Hyp (m/z 164, 182) efficient quantitation of Hyp in collagen is possible within the broad range of 5-1000 ng with a lower limit of detection of 0.5 ng per injection. Measurement of 18O2 incorporation into collagen is possible by selected ion monitoring of the m/z 182 ion formed only from the monoacetylated derivative, N-TFA-Hyp, produced by methanol solvolysis of the N,O-TFA-Hyp derivative, as proposed herein.  相似文献   

8.
A high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS) method was established for the determination of gambogic acid (GA) in human plasma using ursolic acid as the internal standard (I.S.). Plasma samples were extracted with ethyl acetate and separated on a Hanbon Lichrospher 5-C18 column with a mobile phase of acetonitrile-tetrahydrofuran-water (70:23:7, v/v). Gambogic acid was determined by using atmospheric pressure chemical ionization (APCI) in a single quadrupole mass spectrometer. HPLC-APCI-MS was performed in the selected ion monitoring (SIM) mode using target ions at [M-H](-)m/z 627.4 for gambogic acid and [M-H](-)m/z 455.4 for the I.S. Calibration curve was linear over the range of 3.108-4144 microg/L. The lower limit of quantification was 3.108 microg/L. The intra- and inter-run precisions were less than 12.3 and 14.1%, respectively. The method has been successfully applied to study the pharmacokinetics of gambogic acid in patients with malignant tumour.  相似文献   

9.
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method (LC-MS-MS) had been developed and validated for the quantitation of astragaloside IV (AGS-IV)-an active constituent of Radix Astragali in rat plasma. Assay method was developed by a series of operations described as below. The plasma proteins were precipitated with acetonitrile and digoxin was used as the internal standard (I.S.). The sample solution containing astragaloside IV and the I.S. were obtained and subsequently injected into a LC-MS-MS system following by a gradient elution at a slow flow rate combined with a valve diversion during the liquid chromatography. Chromatographic separation was achieved on a C4 (2.1 mmx10 mm) column with a gradient mobile phase comprised of 90% methanol in water and 10 mM ammonium acetate buffer. The analytes were detected with a PE Sciex API 3000 mass spectrometer using turbo ion spray with positive ionization. Ions monitored in the multiple reaction-monitoring (MRM) modes were m/z 785.5 (precursor ion) to m/z 143.2 (product ion) for AGS-IV and m/z 781.2 (precursor ion) to m/z 243.3 (product ion) for digoxin (I.S.). The method was validated over a linear range of 1-1000 ng/ml. The low limit of quantitation was 1.0 ng/ml. Results from a 3-day validation study demonstrated that the developed method possessed good precision (CV% values were between 5.9 and 7.6%) and accuracy (96.5-102.1%) across the calibration range. The recoveries were 91 and 90% for astragaloside IV and I.S., and no significant matrix effects were observed. QC samples were stable when kept at room temperature for 4 h, at -20 degrees C for 4 weeks, and after three freeze/thaw cycles.  相似文献   

10.
Lima ES  Di Mascio P  Rubbo H  Abdalla DS 《Biochemistry》2002,41(34):10717-10722
Nitric oxide (*NO) is a pervasive free radical species that concentrates in lipophilic compartments to serve as a potent inhibitor of lipid and low-density lipoprotein oxidation processes. In this study, we synthesized, characterized, and detected nitrated derivatives of linoleic acid (18:2) in human blood plasma using high-pressure liquid chromatography coupled with electrospray ionization tandem mass spectrometry. While the reaction of nitronium tetrafluoroborate with 18:2 presented ions with a mass/charge (m/z) ratio of 324 in the negative ion mode, characteristic of nitrolinoleate (LNO(2)), the reaction of nitrite (NO(2)(-)) with linoleic acid hydroperoxide yielded nitrohydroxylinoleate (LNO(2)OH, m/z 340). Further analysis by MS/MS gave a major fragment at m/z 46, characteristic of a nitro group (-NO(2)) present in the parent ion. This was confirmed by using [(15)N]O(2), which gave products of m/z 325 and 341, that after fragmentation yielded a daughter ion at m/z 47. Moreover, a C-NO(2) structure was also demonstrated in LNO(2)OH by nuclear magnetic resonance spectroscopy ((15)N NMR, delta 375.9), as well as by infrared analysis in both LNO(2)OH (nu(max) = 3427, 1553, and 1374 cm(-1)) and LNO(2) (nu(max) = 1552 and 1373 cm(-1)). Stable products with m/z of 324 and 340, which possessed the same chromatographic characteristics and fragmentation pattern as synthesized standards, were found in human plasma of normolipidemic and hyperlipidemic donors. The presence of these novel nitrogen-containing oxidized lipid adducts in human plasma could represent "footprints" of the antioxidant action of *NO on lipid oxidation and/or a pro-oxidant and nitrating action of *NO-derived species.  相似文献   

11.
A sensitive high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for simultaneous determination of procaine and its metabolite p-aminobenzoic acid (PABA). N-Acetylprocainamide (NAPA) was used as an internal standard for procaine and PABA analysis. This assay method has also been validated in terms of linearity, lower limit of detection, lower limit of quantitation, accuracy and precision as per ICH guidelines. Chromatography was carried out on an XTerra MS C(18) column and mass spectrometric analysis was performed using a Quattro Micro mass spectrometer working with electro-spray ionization (ESI) source in the positive ion mode. Enhanced selectivity was achieved using multiple reaction monitoring (MRM) functions, m/z 237-->100, m/z 138-->120, and m/z 278-->205 for procaine, PABA and NAPA, respectively. Retention times for PABA, procaine and NAPA were 4.0, 4.7 and 5.8min, respectively. Linearity for each calibration curve was observed across a range from 100nM to 5000nM for PABA, and from 10nM to 5000nM for procaine. The intra- and inter-day relative standard deviations (RSD) were <5%.  相似文献   

12.
A specific and sensitive quantitative assay has been developed using high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI-MS) for the simultaneous quantitation of the antitumor drug ifosfamide (IFM) and its two metabolites, N2-deschloroethylifosfamide (N2-DCE-IFM) and N3-deschloroethylifosfamide (N3-DCE-IFM) in microsomal medium. The analytes and the internal standard (cyclophosphamide) were isolated by ethylacetate extraction from rat liver microsomes. They were analysed on a Nucleosil C18 HD column (125 mm x 4 mm, 5 microm) using a step gradient with the mobile phase (2 mM ammonium formate and methanol). The HPLC-ESI-MS method used selected ion monitoring of ions m/z 199.1 Th and m/z 261.1 Th and was validated in the concentrations ranges of 100-5000 ng/mL for IFM and 50-2500 ng/mL for its N-deschloroethylated metabolites (DCE-IFM) with good accuracy and precision (CV less than 15%). The low limits of quantitation (LLOQ) were found at 50 ng/mL for N-deschloroethylated metabolites and at 100 ng/mL for the parent drug (IFM). The method was applied for the determination of ifosfamide and its N-deschloroethylated metabolites in rat microsomal incubations.  相似文献   

13.
We describe a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for levocetirizine quantification (I) in human plasma. Sample preparation was made using a fexofenadine (II) addition as internal standard (IS), liquid-liquid extraction using cold dichloromethane, and dissolving the final extract in acetonitrile. I and II (IS) were injected in a C18 column and the mobile phase composed of acetonitrile:water:formic acid (80.00:19.90:0.10, v/v/v) and monitored using positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 389>201 for I and m/z 502>467 for II. The limit of quantification and the dynamic range achieved were 0.5ng/mL and 0.5-500.0ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as its application to the analysis of plasma samples taken up to 48h after oral administration of 5mg of levocetirizine dichloridrate in healthy volunteers demonstrate its applicability to bioavailability studies.  相似文献   

14.
A sensitive high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) assay was developed to determine raltitrexed in human plasma. After addition of benazeprilat as the internal standard (IS), methanol was used to produce a protein-free extract. Chromatographic separation was achieved with a Zorbax SB-C18 column (Narrow-Bore 2.1 mmx150 mm, 5-microm) using a mobile phase of acetonitrile-water containing 0.1% formic acid and 2% methanol (21.9:78.1, v/v). Raltitrexed was determined with electrospray ionization-mass spectrometry. HPLC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at [M+H]+ m/z 459.1 for raltitrexed and [M+H]+ m/z 397.1 for IS. Calibration curves were linear over the range of 2.0-3000 ng/ml. The lower limit of quantification was 2.0 ng/ml. The intra- and inter-batch variability values were less than 6.7% and 10.3%, respectively. The mean plasma extraction recovery of raltitrexed was in the range of 85.2-91.1%. The method was successfully applied to determine the plasma concentrations of raltitrexed in eight Chinese colorectal cancer patients.  相似文献   

15.
A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV相似文献   

16.
A method for quantifying two toxic glycoalkaloids, alpha-solanine and alpha-chaconine, in potato (Solanum tuberosum) tuber tissue was developed using HPLC-electrospray ionisation (ESI)/MS. Potato samples were extracted with 5% aqueous acetic acid, and the extracts were subjected directly to HPLC-ESI/MS after filtration. By determining the intensities of the protonated molecules of alpha-solanine (m/z 868) and alpha-chaconine (m/z 852) using selected ion monitoring (positive ion mode), a sensitive assay was attained with detection limits of 38 and 14 ppb for the two glycoalkaloids, respectively. The high sensitivity and selectivity of MS detection effectively reduced the time of analysis thus enabling a high throughput assay of glycoalkaloids in potato tubers.  相似文献   

17.
A new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method operated in the positive/negative electrospray ionization (ESI) switching mode has been developed and validated for the simultaneous determination of asperosaponin VI and its active metabolite hederagenin in rat plasma. After addition of internal standards diazepam (for asperosaponin VI) and glycyrrhetic acid (for hederagenin), the plasma sample was deproteinized with acetonitrile, and separated on a reversed phase C18 column with a mobile phase of methanol (solvent A)-0.05% glacial acetic acid containing 10 mM ammonium acetate and 30 μM sodium acetate (solvent B) using gradient elution. The detection of target compounds was done in multiple reaction monitoring (MRM) mode using a tandem mass spectrometry equipped with positive/negative ion-switching ESI source. At the first segment, the MRM detection was operated in the positive ESI mode using the transitions of m/z 951.5 ([M+Na](+))→347.1 for asperosaponin VI and m/z 285.1 ([M+H](+))→193.1 for diazepam for 4 min, then switched to the negative ESI mode using the transitions of m/z 471.3 ([M-H](-))→471.3 for hederagenin and m/z 469.4 ([M-H](-))→425.4 for glycyrrhetic acid, respectively. The sodiated molecular ion [M+Na](+) at m/z 951.5 was selected as the precursor ion for asperosaponin VI, since it provided better sensitivity compared to the deprotonated and protonated molecular ions. Sodium acetate was added to the mobile phase to make sure that abundant amount of the sodiated molecular ion of asperosaponin VI could be produced, and more stable and intensive mass response of the product ion could be obtained. For the detection of hederagenin, since all of the mass responses of the fragment ions were very weak, the deprotonated molecular ion [M-H](-)m/z 471.3 was employed as both the precursor ion and the product ion. But the collision energy was still used for the MRM, in order to eliminate the influences induced by the interference substances from the rat plasma. The validated method was successfully applied to study the pharmacokinetics of asperosaponin VI and its active metabolite hederagenin in rat plasma after oral administration of asperosaponin VI at a dose of 90 mg/kg.  相似文献   

18.
An analytical method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the simultaneous identification and quantification of droperidol and ondansetron in human plasma. The two drugs were isolated from 0.5 mL of plasma using a basic liquid-liquid extraction with diethyl ether/heptane (90/10, v/v) and tropisetron and haloperidol as internal standards, with satisfactory extraction recoveries. They were separated on a 5-μm C(18) Highpurity column (150 mm×2.1 mm I.D.) maintained at 30°C. The elution was achieved isocratically with a mobile phase of 2 mM HCOONH(4) pH 3.8 buffer/acetonitrile (60/40, v/v) at a flow rate of 200 μL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the [M+H] (+) ion at m/z=294.0 for ondansetron, m/z=285.2 for tropisetron, m/z=380.0 for droperidol and m/z=376.0 for haloperidol. The most intense daughter ion of ondansetron (m/z=212.0) and droperidol (m/z=194.0) were used for quantification. Retention times for tropisetron, ondansetron, droperidol and haloperidol were 2.50, 2.61, 3.10 and 4.68 min, respectively. Calibration curves were linear for both compounds in the 0.50-500 ng/mL range. The limits of detection and quantification were 0.10 ng/mL and 0.50 ng/mL, respectively. The intra- and inter-assay precisions were lower than 6.4% and intra- and inter-assay recoveries were in the 97.6-101.9% range for the three 3, 30 and 300 ng/mL concentrations. This method allows simultaneous and rapid measurement of droperidol and ondansetron, which are frequently co-administrated for the prevention of postoperative nausea and vomiting.  相似文献   

19.
A sensitive and specific method for determination of viaminate in human plasma by using high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was developed in this study. The plasma samples were simply deproteinated, extracted, evaporated, and then reconstituted in 200 microl of methanol prior to analysis. Chromatographic separation was carried out on a Shimadzu VP-ODS column (250 mm x 2.0 mm, 5 microm) with a mobile phase of methanol-water (95:5, v/v) at a flow rate of 0.2 ml/min. Quantification was performed in the negative-ion electrospray ionization mode by selected ion monitoring of the product ions at m/z 164 for viaminate and m/z 109 for testosterone propionate which was used as the internal standard. The corresponding parent ions were m/z 446 and m/z 345. A linear calibration curve was observed within the concentration range of 0.10-200 ng/ml. The lowest limit of quantitation (LLOQ) was 0.1 ng/ml. The extraction-efficiency at three concentrations was 100.7, 93.6, and 99.7%. Practical utility of this new LC-MS/MS method was confirmed in pilot pharmacokinetic studies in humans following oral administration.  相似文献   

20.
A fast, sensitive and accurate method for the determination of gemcitabine (difluorodeoxycytidine; dFdC) and deoxycytidine (CdR) in human plasma/tissue was developed using LC-MS/MS techniques. Effectiveness of the method is illustrated with the analysis of plasma from a phase I trial of dFdC administered as a 24h infusion. The method was developed using (15)N(3) CdR as an internal standard across the concentration range of 1-500ng/ml, using a cold alcohol-protein precipitation followed by desorption with freeze drying. Sample clean-up for LC-MS/MS analysis was performed by an innovative liquid/liquid back extraction with ethyl acetate and water. Chromatography was performed using a Chrompak-spherisorb-phenyl-column (3.1mmx200mm, 5microm) with a 50mM formic acid: acetonitrile (9:1) mobile phase eluted at 1ml/min. Extracted samples were observed to be stable for a minimum of 48h after extraction when kept at 4 degrees C. Detection was performed using an atmospheric pressure chemical ionization (APCI) source and mass spectrometric positive multi-reaction-monitoring-mode (+MRM) for dFdC (264 m/z; 112 m/z), CdR (228 m/z; 112 m/z), and (15)N(3) CdR (231 m/z; 115 m/z) at an ion voltage of +3500V. The accuracy, precision and limit-of-quantitation (LOQ) were as follows: dFdC: 99.8%, +/-7.9%, 19nM; CdR: 100.0%, +/-5.3%, 22nM, linear range LOQ to 2microM. During 24h infusion dFdC levels were detected with no interference from either CdR or difluorodeoxyuridine (dFdU). CdR co-eluted with dFdC but selectivity demonstrated no "crosstalk" between the compounds. In conclusion the analytical assay was very sensitive, reliable and robust for the determination of plasma and tissue concentrations of dFdC and CdR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号