首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method was developed for the determination of tafenoquine (I) in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with methanol containing [2H3(15N)]tafenoquine (II) to act as an internal standard. The supernatant was injected onto a Genesis-C18 column without any further clean-up. The mass spectrometer was operated in the positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring mode. The assay required 50 microl of plasma and was precise and accurate within the range 2 to 500 ng/ml. The average within-run and between-run relative standard deviations were < 7% at 2 ng/ml and greater concentrations. The average accuracy of validation standards was generally within +/- 4% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can safely be stored for at least 8 months at approximately -70 degrees C. The method was very robust and has been successfully applied to the analysis of clinical samples from patients and healthy volunteers dosed with I.  相似文献   

2.
An analytical method has been developed for the simultaneous determination of a novel orally active angiotensin-converting enzyme inhibitor (CGS 16617) and a stable isotope-labeled analog. Both compounds are isolated from human plasma using an ion-exchange column, derivatized with pentafluoropropionic anhydride and pentafluoropropanol, and analyzed by gas chromatography/mass spectrometry. After splitless injection on a methyl-silicon column, the compound is detected using negative ion chemical ionization with nitrous oxide as a reagent gas. CGS 16617 labeled with four deuteriums and two 13C is used as an internal standard. The accuracy and precision of the method, expressed as the overall mean +/- SD recovery obtained from two sets of 36 quality-control samples used during a clinical study (concentration range 0.2-100 ng ml-1 plasma), was 96.1 +/- 16.2% for unlabeled drug and 97.6 +/- 14.4% for the D4-labeled drug (concentration range 0.2-100 ng ml-1 plasma). The limit of quantification using 1 ml plasma is 0.2 ng ml-1 for both labeled and unlabeled drug.  相似文献   

3.
An assay employing automated solid-phase extraction (SPE) followed by high-performance liquid chromatography with positive ion TurboIonspray tandem mass spectrometry (LC-MS-MS) was developed and validated for the quantification of rosuvastatin (Crestor) in human plasma. Rosuvastatin is a hydroxy-methyl glutaryl coenzyme A reductase inhibitor currently under development by AstraZeneca. The standard curve range in human plasma was 0.1-30 ng/ml with a lower limit of quantification (LLOQ) verified at 0.1 ng/ml. Inaccuracy was less than 8% and imprecision less than +/-15% at all concentration levels. There was no interference from endogenous substances. The analyte was stable in human plasma following three freeze/thaw cycles and for up to 6 months following storage at both -20 and -70 degrees C. The assay was successfully applied to the analysis of rosuvastatin in human plasma samples derived from clinical trials, allowing the pharmacokinetics of the compound to be determined.  相似文献   

4.
A rapid, sensitive and reliable method was developed to quantitate omeprazole in human plasma using liquid chromatography-tandem mass spectrometry. The assay is based on protein precipitation with acetonitrile and reversed-phase liquid chromatography performed on an octadecylsilica column (55 mm x 2mm, 3 microm particles), the mobile phase consisted of methanol-10 mM ammonium acetate (60:40, v/v). Omeprazole and flunitrazepam, the internal standard, elute at 0.80+/-0.10 min with a total run time 1.35 min. Quantification was through positive ion mode and selected reaction monitoring mode at m/z 346.1-->197.9 for omeprazole and m/z 314.0-->268.0 for flunitrazepam, respectively. The lower limit of quantitation was 1.2 ng/ml using 0.25 ml of plasma and linearity was observed from 1.2 to 1200 ng/ml. Within-day and between-day precision expressed by relative standard deviation was less than 5% and inaccuracy did not exceed 12%. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

5.
We have developed a sensitive, selective and reproducible reversed-phase high-performance liquid chromatography method coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS) for the simultaneous quantification of midazolam (MDZ) and its major metabolite, 1'-hydroxymidazolam (1'-OHM) in a small volume (200 microl) of human plasma. Midazolam, 1'-OHM and 1'-chlordiazepoxide (internal standard) were extracted from alkalinised (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with 1-chlorobutane. The chromatographic separation was performed on a reversed-phase HyPURITY Elite C18 (5 microm particle size; 100 mm x 2.1mm i.d.) analytical column using an acidic (pH 2.8) mobile phase (water-acetonitrile; 75:25% (v/v) containing formic acid (0.1%, v/v)) delivered at a flow-rate of 200 microl/min. The mass spectrometer was operated in the positive ion mode at the protonated-molecular ions [M+l]+ of parent drug and metabolite. Calibration curves in spiked plasma were linear (r2 > or = 0.99) from 15 to 600 ng/ml (MDZ) and 5-200 ng/ml (1'-OHM). The limits of detection and quantification were 2 and 5 ng/ml, respectively, for both MDZ and 1'-OHM. The mean relative recoveries at 40 and 600 ng/ml (MDZ) were 79.4+/-3.1% (n = 6) and 84.2+/-4.7% (n = 8), respectively; for 1'-OHM at 30 and 200 ng/ml the values were 89.9+/-7.2% (n = 6) and 86.9+/-5.6% (n = 8), respectively. The intra-assay and inter-assay coefficients of variation (CVs) for MDZ were less than 8%, and for 1'-OHM were less than 13%. There was no interference from other commonly used antimalarials, antipyretic drugs and antibiotics. The method was successfully applied to a pharmacokinetic study of MDZ and 1'-OHM in children with severe malaria and convulsions following administration of MDZ either intravenously (i.v.) or intramuscularly (i.m.).  相似文献   

6.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed to determine meloxicam of low concentration in human plasma. After a simple sample preparation procedure by one-step protein precipitation with methanol, meloxicam and the internal standard piroxicam were chromatographed on a Zorbax SB C(18) column. The mobile phase consisted of acetonitrile-water-formic acid (80:20:0.2, v/v/v). Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via electrospray ionization (ESI) source. The method had a lower limit of quantification of 0.10 ng/ml. The calibration curve was demonstrated to be linear over the concentration range of 0.10-50.0 ng/ml. The assay was specific, accurate (percentage deviations from nominal concentrations were within +/-2.5%), precise (intra- and inter-day relative standard deviation (R.S.D.) <7%). The validated method was successfully applied to the determination of meloxicam in human plasma collected up to 180 h after a transdermal administration of 30 mg meloxicam for evaluation of the pharmacokinetics.  相似文献   

7.
A sensitive and highly selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed to determine nimodipine in human plasma. The analyte and internal standard nitrendipine were extracted from plasma samples by n-hexane-dichloromethane-isopropanol (300:150:4, v/v/v), and chromatographed on a C(18) column. The mobile phase consisted of methanol-water-formic acid (80:20:1, v/v/v). Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI) source. The method has a limit of quantification of 0.24 ng/ml. The linear calibration curves were obtained in the concentration range of 0.24-80 ng/ml. The intra- and inter-day precisions were lower than 4.4% in terms of relative standard deviation (R.S.D.), and the accuracy ranged from 0.0 to 5.8% in terms of relative error (RE). This validated method was successfully applied for the evaluation of pharmacokinetic profiles of nimodipine tablets administered to 18 healthy volunteers.  相似文献   

8.
A sensitive and specific HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma has been developed and validated. Plasma samples were analyzed after a simple, one-step protein precipitation clean-up with trichloroacetic acid using a polymer-based amino high-performance liquid chromatography (HPLC) column and a water/acetonitrile mobile phase elution gradient, with d-[1-(13)C]glucosamine as the internal standard. Detection was performed by mass spectrometry, using an electrospray source and employing multiple reaction monitoring to separately monitor glucosamine and the internal standard. The limit of quantification of the method was 10ng/ml of glucosamine and the calibration curve showed a good linearity up to 1000ng/ml. The precision (R.S.D.) and the accuracy (bias) of the method at the limit of quantification were 13.8 and 4.0%, respectively, and the mean recovery of glucosamine at three concentration levels was 101.6+/-5.7%. The method was applied for the determination of glucosamine concentrations in human plasma samples collected from untreated healthy volunteers and, in a separate bioavailability study, to evaluate plasma glucosamine pharmacokinetics profiles after oral administration of crystalline glucosamine sulfate.  相似文献   

9.
Bombesin (BN) and its mammalian equivalent, gastrin-releasing peptide (GRP), stimulate cell proliferation and are involved in the pathogenesis of several types of human cancer. BN/GRP and their receptors were shown to be critical for the growth of various human malignancies, such as small-cell lung, prostate, ovary, stomach and breast cancers in the human tumor xenograft model. In the present study, a fast, sensitive, robust method was developed for the determination and quantification of a BN/GRP receptor antagonist RC-3095 (D-Tpi-Gln-Trp-Ala-Val-Gly-His-Leupsi(CH2NH)Leu-NH2), in human plasma by liquid chromatography coupled with tandem mass spectrometry. RC-3095 was extracted from 0.2 ml human plasma by protein precipitation using cold acetonitrile (0.4 ml). The method has a chromatographic run of 10 min using a C(8) analytical column (150 mm x 4.6 mm i.d.) and the linear calibration curve over the range was linear from 20 to 10000 ng ml(-1) (r(2)>0.994). The between-run precision, based on the relative standard deviation replicate quality controls, was 5.7% (60 ng ml(-1)), 7.1% (600 ng ml(-1)) and 6.8% (8000 ng ml(-1)). The between-run accuracy was +/-0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively. The developed procedure allows the quantitative determination of peptide RC-3095 for pharmacokinetics studies in human plasma.  相似文献   

10.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.  相似文献   

11.
Glipizide and rosiglitazone are widely used to treat Type 2 diabetes. In order to investigate drug-drug protein binding interaction between glipizide and rosiglitazone, a method was developed and validated for simultaneously determining the free (unbound) fraction of glipizide and rosiglitazone in plasma employing equilibrium dialysis for the separation of free drug and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantitation. Post-dialysis human plasma or buffer samples of 0.2 ml were extracted using a liquid-liquid extraction procedure and analyzed by a high performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a Zorbax SB-Phenyl column, ionized using an atmospheric pressure electrospray ionization source and analyzed in positive ion mode with multiple reaction monitoring. The ion transitions monitored were m/z 446-->321 for glipizide, m/z 358-->135 for rosiglitazone, and m/z 271-->155 for tolbutamide (internal standard, IS). The chromatographic run time was 5 min per injection, with retention times of 2.3, 3.4 and 2.3 min for glipizide, rosiglitazone and IS, respectively. The calibration curves of glipizide and rosiglitazone were over the range of 1-2000 ng/ml (r(2)>0.9969) in the combined matrix of human plasma and isotonic sodium phosphate buffer (1:1, v/v). The inter-assay precision and accuracy of the quality control samples were <10.9% of coefficient of variability and >93.5% and 94.5% of nominal concentration for glipizide and rosiglitazone, respectively. The lower limit of quantitation of both glipizide and rosiglitazone was 1.0 ng/ml. Both glipizide and rosiglitazone bound to plasma protein extensively (>99% bound). Glipizide and rosiglitazone free fraction averaged 0.678+/-0.071 and 0.389+/-0.061%, respectively, at plasma concentration of 1000 ng/ml. This developed method proves reproducible and sensitive and its application to clinical samples is also reported.  相似文献   

12.
A gas chromatographic-mass spectrometric (GC-MS) method is described for the determination of human plasma levels of gamma-butyrolactone (GBL) is described. The method is sensitive and simple. The plasma sample spiked with the internal standard was extracted by dichloromethane (CH(2)Cl(2)) in acidic conditions, and the concentrated organic layer was injected into GC-MS. Because of endogenous GBL in human plasma, the method used a standard calibration curve. The calibration curve was linear from 10 to 1000 ng/ml. The method has been validated for accuracy and precision with the relative error and C.V. for intra- and inter-day within 10%. GBL-spiked plasma samples stored at -80 degrees C were stable for a 3-month period. The stability of plasma samples after three cycles of freezing and thawing and of prepared samples on an autosampler for 48 h were demonstrated. Plasma concentrations of GBL before and after administration of UFT were 24.3+/-14.2 and 84.9+/-22.4 ng/ml, respectively.  相似文献   

13.
The validation of a method for the determination of mevalonic acid (MVA; after conversion to the lactone, MVAL) in human plasma, using high-performance liquid chromatography with tandem mass spectrometry (HPLC-MS-MS), is reported. MVAL and deuterated internal standard were extracted from human plasma samples using automated solid-phase extraction. Analysis was conducted by column-switching, reversed-phase LC-MS-MS, using two hyper-cross-linked styrene-divinylbenzene copolymer sorbent reversed-phase columns. An assay range of 0.2-35 ng/ml and a lower limit of quantitation (LLOQ) of 0.2 ng/ml were achieved with acceptable accuracy and precision. MVA was stable in plasma under a variety of storage conditions.  相似文献   

14.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

15.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-dammarane-3beta,12beta,20,25-tetrol (25-OH-PPD) in rat. Ginsenoside Rh(2) was employed as an internal standard. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. The mobile phase consisted of methanol-acetonitrile-10 mmol/l aqueous ammonium acetate (42.5:42.5:15, v:v:v), which was pumped at 0.4 ml/min. The analytical column (50 mm x 2.1 mm i.d.) was packed with Venusil XBP C8 material (3.5 microm). The standard curve was linear from 10 to 3000 ng/ml. The assay was specific, accurate (accuracy between -1.19 and 2.57% for all quality control samples), precise and reproducible (within- and between-day precisions measured as relative standard deviation were <5% and <7%, respectively). 25-OH-PPD in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 6h. The method had a lower limit of quantitation of 10 ng/ml, which offered a satisfactory sensitivity for the determination of (25-OH-PPD) in plasma. This quantitation method was successfully applied to pharmacokinetic studies of 25-OH-PPD after both an oral and an intravenous administration to rats and the absolute bioavailability is 64.8+/-14.3%.  相似文献   

16.
In this work, we present the development and validation of a tandem mass spectrometry method for the quantitative determination of methoxyamine (CH3ONH2), a potential new chemotherapeutic agent, in human and mouse plasma. Methoxyamine together with the internal standard (I.S.) methoxyl-D3-amine was directly derivatized in plasma sample with a novel chemical agent 4-(N,N-diethylamino)benzaldehyde. The product solution was injected into an on-line Oasis HLB extraction column (2.1 mm x 20 mm) for analyte extraction. After the elution of extractives, the derivatized analytes were monitored by the positive-electrospray-ionization mass spectrometry (ESI-MS-MS). The structures of derivatized analytes were elucidated by fragmentation. Quantitation of plasma methoxyamine was carried out by the multiple reaction monitoring (MRM) mode. This method had a linear calibration range of 1.00-1000 ng/ml with a correlation coefficient of 0.9999 for methoxyamine in both human and mouse plasma. The limit of detection (LOD) and limit of quantification (LOQ) for methoxyamine in plasma were 0.150 and 0.500 ng/ml, respectively. It was demonstrated that the method had high recovery and accuracy (90.1-94.7 and 90.1-96.3%), as well as excellent intra- and inter-assay precision (2.2 and 3.7%), at three concentration levels (5.00, 50.0, 500 ng/ml). This method has been used to analyze the plasma levels of methoxyamine in samples obtained from male CD1 mice after bolus intraperitoneal injection of 2, 5 and 20mg methoxyamine hydrochloride (CH3ONH2.HCl) per kilogram mouse.  相似文献   

17.
A high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) procedure for the simultaneous determination of diazepam from avizafone, atropine and pralidoxime in human plasma is described. Sample pretreatment consisted of protein precipitation from 100microl of plasma using acetonitrile containing the internal standard (diazepam D5). Chromatographic separation was performed on a X-Terra MS C8 column (100mmx2.1mm, i.d. 3.5microm), with a quick stepwise gradient using a formate buffer (pH 3, 2mM) and acetonitrile at a flow rate of 0.2ml/min. The triple quadrupole mass spectrometer was operated in positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges of 1-500ng/ml for diazepam, 0.25-50ng/ml for atropine and 5-1000ng/ml for pralidoxime. The coefficients of variation were always <15% for both intra-day and inter-day precision for each analyte. Mean accuracies were also within +/-15%. This method has been successfully applied to a pharmacokinetic study of the three compounds after intramuscular injection of an avizafone-atropine-pralidoxime combination, in healthy subjects.  相似文献   

18.
A simple, rapid, novel and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of tacrolimus (I) in human plasma, a narrow therapeutic index, potent macrolide immunosuppressive drug. The analyte and internal standard (tamsulosin (II)) were extracted by liquid-liquid extraction with t-butylmethylether using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on reverse phase Xterra ODS column with a mobile phase of 99% methanol and 1% 10mM ammonium acetate buffer. The deprotonate of analyte was quantitated in negative ionization by multiple reaction monitoring (MRM) with a mass spectrometer. The mass transitions m/z 802.5-->560.3 and m/z 407.2-->151.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.05-25ng/ml for tacrolimus in human plasma. The lower limit of quantitation was 50pg/ml with a relative standard deviation of less than 20%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 2min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in comparative bioavailability studies. The tacrolimus plasma concentration profile could be obtained for pharmacokinetic study. The observed maximum plasma concentration (C(max)) of tacrolimus (5mg oral dose) is 440pg/ml, time to observed maximum plasma concentration (T(max)) is 2.5h and elimination half-life (T(1/2)) is 21h.  相似文献   

19.
The validation of a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the determination of the selective cyclooxygenase-2 inhibitor etoricoxib in human plasma with phenazone as internal standard is described. The plasma samples were extracted by solid-phase extraction using polymer-based cartridges. Chromatography was carried out on a short, narrow bore RP C(18) column (30x2 mm). Detection was achieved by a Sciex API 3000 triple quadrupole mass spectrometer equipped with a turbo ion spray source working in positive ion mode. The respective mass transitions used for quantification of etoricoxib and phenazone were m/z 359.2-->280.2 and m/z 189.0-->104.1. The analytical method was validated over the concentration range 0.2-200 ng/ml. The limit of quantification was 0.2 ng/ml. The method is applicable to pharmacokinetic studies in humans.  相似文献   

20.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method with positive electrospray ionization (ESI) was developed for the quantification of ranolazine in human plasma. After liquid-liquid extraction of ranolazine and internal standard (ISTD) phenoprolamine from a 100 microl specimen of plasma, HPLC separation was achieved on a Nova-Pak C(18) column, using acetonitrile-water-formic acid-10% n-butylamine (70:30:0.5:0.08, v/v/v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 428.5-->m/z 279.1 for ranolazine and m/z 344.3-->m/z 165.1 for the internal standard, respectively. Linear calibration curves were obtained in the concentration range of 5-4000 ng/ml, with a lower limit of quantitation (LLOQ) of 5 ng/ml. The intra- and inter-day precision values were below 3.7% and accuracy was within +/-3.2% at all three quality control (QC) levels. This method was found suitable for the analysis of plasma samples collected during the phase I pharmacokinetic studies of ranolazine performed in 28 healthy volunteers after single oral doses from 200 mg to 800 mg.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号