首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
Xia YQ  Liu DQ  Bakhtiar R 《Chirality》2002,14(9):742-749
An online sample extraction chiral bioanalytical method was developed and validated for the quantification of terbutaline, a beta2-selective adrenoceptor agonist, spiked into human plasma by using two extraction columns and a chiral stationary phase (CSP) in conjunction with liquid chromatography tandem mass spectrometry (LC-MS/MS). In this method, two Oasis HLB extraction columns were used in parallel for plasma sample purification and a Chirobiotic T CSP was used for enantiomeric separation. Atmospheric pressure chemical ionization MS/MS was employed in multiple reaction monitoring mode for the detection and quantification. Subsequent to the addition of an internal standard solution, the plasma samples were directly injected onto the system for extraction and analysis. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for reconditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a shorter run time and higher throughput. A lower limit of quantification of 1.0 ng/mL was achieved using only 50 microliter of human plasma. The method was validated with a dynamic range of 1.0-200 ng/mL. The intra- and interday precision was no more than 11% CV and the assay accuracy was between 94-106%.  相似文献   

2.
An enantioseparation of the antipsychotic drug butaclamol in human plasma by high-performance liquid chromatography (HPLC) with solid phase extraction is presented. The separation was achieved on the vancomycin macrocyclic antibiotic chiral stationary phase (CSP) Chirobiotic V with a polar ionic mobile phase (PIM) consisting of methanol : glacial acetic acid : triethylamine (100:0.2:0.05, v/v/v) at a flow rate of 0.5 ml/min. The detection wavelength was 262 nm. Bond Elut C18 solid phase extraction cartridges were used in the sample preparation of butaclamol samples from plasma. The method was validated over the range of 100-3,000 ng/ml for each enantiomer concentration (R(2) > 0.999). Recoveries for (+)- and (-)-butaclamol were in the range of 94-104% at the 300-2,500 ng/ml level. The method proved to be precise (within-run precision ranged from 1.1-2.6% and between-run precision ranged from 1.9-3.2%) and accurate (within-run accuracies ranged from 1.5-5.8% and between-run accuracies ranged from 2.7-7.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for each enantiomer in human plasma were 100 ng/ml and 50 ng/ml, respectively.  相似文献   

3.
A bioanalytical method for the analysis of artesunate and its metabolite dihydroartemisinin in human plasma using high throughput solid-phase extraction in the 96-wellplate format and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. The method was validated according to published FDA guidelines and showed excellent performance. The within-day and between-day precisions expressed as RSD, were lower than 7% at all tested concentrations including the lower limit of quantification. Using 50 microl plasma the calibration range was 1.19-728 ng/ml with a limit of detection at 0.5 ng/ml for artesunate and 1.96-2500 ng/ml with a limit of detection at 0.6 ng/ml for dihydroartemisinin. Using 250 microl of plasma sample the lower limit of quantification was decreased to 0.119 ng/ml for artesunate and 0.196 ng/ml dihydroartemisinin. Validation of over-curve samples in plasma ensured that accurate estimation would be possible with dilution if samples went outside the calibration range. The method was free from matrix effects as demonstrated both graphically and quantitatively.  相似文献   

4.
A rapid and sensitive high-performance thin-layer chromatographic (HPTLC) method was developed and validated for the quantitative estimation of boswellic acids in formulation containing Boswellia serrata extract (BSE) and 11-keto beta-boswellic acid in human plasma. Simple extraction method was used for isolation of boswellic acid from formulation sample and acidified plasma sample. The isolated samples were chromatographed on silica gel 60F(254)-TLC plates, developed using ternary-solvent system (hexane-chloroform-methanol, 5:5:0.5, v/v) and scanned at 260 nm. The linearity range for 11-KBA spiked in 1 ml of plasma was 29.15-145.75 ng with average recovery of 91.66%. The limit of detection and limit of quantification for 11-KBA in human plasma were found to be 8.75 ng/ml and 29.15 ng/ml. The developed method was successfully applied for the assay of market formulations containing BSE and to determine plasma level of 11-keto beta-boswellic acid in a clinical pilot study.  相似文献   

5.
A sensitive and specific liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method has been validated for the measurement of YF476 in human plasma. The method involves a simple liquid-liquid extraction procedure, chromatography of the extracts on a C(18) column, atmospheric pressure chemical ionisation and detection in the multiple reaction monitoring mode. The calibration line was linear over the concentration range 0.1 ng/ml (the limit of quantification) to 25.0 ng/ml. Intra- and inter-batch precision was <14% and intra- and inter-batch accuracy was <11% over the entire calibration range. The bioanalytical method is robust and has been used for the analysis of many samples from human subjects involved in early clinical studies (Phase I).  相似文献   

6.
A fast, simple, and a reliable high-performance liquid chromatography linked with electrochemical detector (HPLC-ECD) method for the assessment of lipoic acid (LA) and dihydrolipoic acid (DHLA) in plasma was developed using naproxen sodium as an internal standard (IS) and validated according to standard guidelines. Extraction of both analytes and IS from plasma (250 μl) was carried out with a single step liquid-liquid extraction applying dichloromethane. The separated organic layer was dried under stream of nitrogen at 40°C and the residue was reconstituted with the mobile phase. Complete separation of both compounds and IS at 30°C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 9 min using acetonitrile: 0.05 M phosphate buffer (pH 2.4 adjusted with phosphoric acid) (52:48, v/v) as a mobile phase pumped at flow rate of 1.5 ml min(-1) using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification for lipoic acid were 500 pg/ml and 3 ng/ml, and for dihydrolipoic acid were 3 ng/ml and 10 ng/ml, respectively. The absolute recoveries of lipoic acid and dihydrolipoic acid determined on three nominal concentrations were in the range of 93.40-97.06, and 93.00-97.10, respectively. Similarly coefficient of variations (% CV) for both intra-day and inter-day were between 0.829 and 3.097% for lipoic acid and between 1.620 and 5.681% for dihydrolipoic acid, respectively. This validated method was applied for the analysis of lipoic acid/dihydrolipoic acid in the plasma of human volunteers and will be used for the quantification of these compounds in patients with oxidative stress induced pathologies.  相似文献   

7.
In this research project, a high-performance liquid chromatography (HPLC) method was developed for the determination of acyclovir (ACV) in plasma. The plasma samples, recharged with acyclovir and in presence of 5'-N-methylcarboxyamidoadenosine (MECA) as an internal standard, were purified using a solid-phase extraction technique with Waters Oasis HLB columns. The separation of the components from the extract was carried out in a LiChrospher 100 RP-18 column for further ultraviolet detection at a wavelength range of 250-260 nm. The mobile phase composition was 18% acetonitrile, sodium dodecylsulphate 5 mM and phosphate buffer at pH 2.6 with an analysis time of 13 min per sample. The average retention time for acyclovir was of 5.0 min and for the internal standard 11.2 min. The calibration curve was linear ranging between 0.05 and 1.80 microg/ml. The detection limit was 0.006 microg/ml with a quantification limit of 0.020 microg/ml. The ACV recuperation percentage for 250 microl of plasma was between 94.7 and 109.7% with a coefficient of variation not higher than 5.2%. This method was developed and validated for use in bioavailability and bioequivalence studies.  相似文献   

8.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

9.
A liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantitation of (R)-, (S)-fluoxetine, and (R)-, (S)-norfluoxetine in ovine plasma. The analytes were extracted from ovine plasma at a basic pH using a single-step liquid-liquid extraction with methyl-tert-butyl ether. Chromatographic separation of all enantiomers was achieved using an AGP-chiral column with a run time of 10 min. (R)-, (S)-fluoxetine, and (R)-, (S)-norfluoxetine were quantitated at the total ion current (TIC) of multiple reaction monitoring (MRM) transitions of m/z 310.2→44.1, m/z 310.2→147.7 for (R)-, (S)-fluoxetine, and m/z 296.2→30.3, m/z 296.2→133.9 for (R)-, (S)-norfluoxetine. This method was validated for accuracy, precision, linearity, range, limit of quantitation (LOQ), selectivity, recovery, dilution integrity, matrix effect, and evaluation of carry-over. Observed accuracy ranges were as follows: (R)-fluoxetine -8.82 to 3.75%; (S)-fluoxetine -10.8 to 1.46%; (R)-norfluoxetine -7.50 to 0.37% and (S)-norfluoxetine -8.77% to -1.33%. Observed precision ranges were as follows: (R)-fluoxetine 5.29-11.5%; (S)-fluoxetine 3.91-11.1%; (R)-norfluoxetine 4.32-7.67% and (S)-norfluoxetine -8.77% to -1.33%. The calibration curves were weighted (1/X(2), n=4) and observed to be linear for all analytes with the following r(2) values: (R)-fluoxetine ≥ 0.997; (S)-fluoxetine ≥ 0.996; (R)-norfluoxetine ≥ 0.989 and (S)-norfluoxetine ≥ 0.994. The analytical range of the method was 1-500 ng/ml with an LOQ of 1 ng/ml for all analytes, using a sample volume of 300 μL.  相似文献   

10.
Several methods for quantification of docetaxel have been described mainly using HPLC. We have developed a new isocratic HPLC method that is as sensitive and simpler than previous methods, and applicable to use in clinical pharmacokinetic analysis. Plasma samples are spiked with paclitaxel as internal standard and extracted manually on activated cyanopropyl end-capped solid-phase extraction columns followed by isocratic reversed-phase HPLC and UV detection at 227 nm. Using this system, the retention times for docetaxel and paclitaxel are 8.5 min and 10.5 min, respectively, with good resolution and without any interference from endogenous plasma constituents or docetaxel metabolites at these retention times. The total run time needed is only 13 min. The lower limit of quantification is 5 ng/ml using 1 ml of plasma. The validated quantitation range of the method is 5–1000 ng/ml with RSDs≤10%, but plasma concentrations up to 5000 ng/ml can be accurately measured using smaller aliquots. This method is also suitable for the determination of docetaxel in urine samples under the same conditions. The method has been used to assess the pharmacokinetics of docetaxel during a phase I/II study of docetaxel in combination with epirubicin and cyclophosphamide in patients with advanced cancer.  相似文献   

11.
An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.  相似文献   

12.
13.
A simple, sensitive and robust liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for quantification of chlorpromazine in rat plasma and brain tissue. Chlorpromazine was extracted from rat plasma and brain homogenate using liquid-liquid extraction. The compounds were separated on a Waters Atlantis dC-18 (30 mm x 2.1 mm i.d., 3 microm) column using a mobile phase of acetonitrile/20 mM ammonium formate (pH 4.25 adjusted with formic acid) with gradient elution. Chlorpromazine was detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The LLOQ was 0.2 ng/ml for plasma and 0.833 ng/g for brain tissue. The method was linear over the concentration range from 0.2 to 200.0 ng/ml for plasma and from 0.833 to 833.3 ng/g for brain tissue. The correlation coefficient (R(2)) values were more than 0.998 for both plasma and brain homogenate. The precision and accuracy for intra-day and inter-day were better than 7.54%. The relative and absolute recovery was above 84.9% and matrix effects were lower than 5.6%. This validated method has been successfully used to quantify the rat plasma and brain tissue concentration of chlorpromazine after chronic treatment.  相似文献   

14.
A fast, sensitive, and enantioselective LC-MS/MS bioanalytical method was developed and validated for the direct determination of individual alprenolol enantiomers in human plasma using cellobiohydrolase (CBH) chiral stationary phases (CSP) along with supported liquid extraction (SLE) procedures. Complete baseline separation of enantiomeric alprenolol was achieved within 2 min in reversed phase chromatography at 0.9 ml/min. SLE in a 96-well plate format was used for sample extraction. The method validation was conducted over the curve range of 0.500-500 ng/ml for each alprenolol enantiomer using 0.0500 ml of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed < or = 7.3% relative standard deviation (RSD) and -6.2 to 8.0% relative error (RE) for both alprenolol enantiomers.  相似文献   

15.
A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 microL) were prepared using solid phase extraction (SPE) columns, and 6.0 microL of the reconstituted eluate was injected onto a Phenomenex CuroSil-PFP 3 mu analytical column (50 mm x 2.0mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC-MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N=11.3, CV< or =14%). This method was validated over a linear range of 100-10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.  相似文献   

16.
BAPTA free acid was identified as the main metabolic product of 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetra(actoxymethyl ester) (BAPTA-AM), a neuroprotective agent in cerebral ischemia, in rats. In this paper, liquid chromatography-ultraviolet (LC-UV) and mass spectrometry/mass spectrometry (LC-MS/MS) methods were employed for the determination of BAPTA free acid in rat urine and feces and rat plasma, respectively. By liquid-liquid extraction and LC-UV analysis, a limit of quantitation of 1000 ng/ml using 0.2 ml rat urine for extraction and 250 ng/ml using 1 ml rat fecal homogenate supernatant for extraction could be reached. The assay was linear in the range of 1000-50,000 ng/ml for rat urine and 250-10,000 ng/ml for rat fecal homogenate supernatant. Because the sensitivity of the LC-UV method was apparently insufficient for evaluating the pharmacokinetic profile of BAPTA in rat plasma, a LC-MS/MS method was subsequently developed for the analysis of BAPTA free acid. By protein precipitation and LC-MS/MS analysis, the limit of quantitation was 5 ng/ml using 0.1 ml rat plasma and the linear range was 5.0-500 ng/ml. Both methods were validated and can be used to support a thorough preclinical pharmacokinetic evaluation of BAPTA-AM liposome injection.  相似文献   

17.
A method for the determination of isosorbide-5-mononitrate (5-ISMN) in human plasma by capillary gas chromatography with electron-capture detection was developed and applied to clinical samples. 9-Fluorenone was used as an internal standard, ethyl acetate was employed for liquid-liquid extraction. The advantage of the extraction procedure is the possibility of a direct injection of the plasma extract, without solvent removal/reconstitution of the sample. The precision and accuracy of the method were satisfactory in the concentration range 10-1600 ng/ml. The lower limit of quantification was 10 ng/ml.  相似文献   

18.
A reversed-phase high-performance liquid chromatographic method has been developed and validated for the quantification of the novel anticancer drug Ecteinascidin 743 in human plasma. The sample pretreatment of the plasma samples involved a solid-phase extraction (SPE) on cyano columns. Propyl-p-hydroxybenzoate was added after the sample pretreatment to correct for variability in injection volumes. The separation was performed on a Zorbax SB-C18 column (75×4.6 mm I.D., particle size 3.5 μm) with acetonitrile–25 mM phosphate buffer, pH 5.0 (70:30, v/v) as the mobile phase. The flow-rate was 1.0 ml/min and the eluent was monitored at 210 nm. The accuracies and precisions of the assay fall within ±15% for all quality control samples and within ±20% for the lower limit of quantitation, which was 1.0 ng/ml using 500 μl of plasma. The overall recovery of the sample pretreatment procedure for Ecteinascidin 743 was 87.0±5.9%. The drug was found to be stable in human plasma at −30°C for at least 2 months. At room temperature Ecteinascidin 743 was stable in human plasma for 5 h at most.  相似文献   

19.
Alentamol hydrobromide, (+)-2-(dipropylamino)-2,3-dihydro-1H-phenalen-5-ol monohydrobromide, is a selective dopamine agonist currently being investigated for the treatment of schizophrenia. This paper describes a reversed-phase high-performance liquid chromatographic-based method for the quantification of alentamol in blood plasma and urine. The method utilizes solid-phase extraction with carboxylic acid-derivatized silica columns. A limit of quantitation of 0.1 ng/ml in plasma was achieved by virtue of selective extraction and fluorescence detection. Example chromatograms of plasma and urine specimens from clinical trials demonstrate the utility of the method.  相似文献   

20.
A sensitive and specific method using liquid chromatography with electrospray ionization mass spectrometry (LC-ESI-MS) has been developed and validated for the identification and quantification of indapamide in human plasma. A simple liquid-liquid extraction procedure was followed by injection of the extracts on to a C18 column with gradient elution and detection using a single quadrupole mass spectrometer in selected ion monitoring (SIM) mode. The method was tested using six different plasma batches. Linearity was established for the concentration range 0.5-100.0 ng/ml, with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (RSD%) was lower than 10%, and accuracy ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.2 ng/ml with 0.2 ml plasma. The proposed method enables the unambiguous identification and quantification of indapamide for pre-clinical and clinical studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号