首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
Thrombogenesis and hemolysis have both been linked to the flow dynamics past heart valve prostheses. To learn more about the particular flow dynamics past mitral valve prostheses in the left ventricle under controlled experimental conditions, an in vitro study was performed. The experimental methods included velocity and turbulent shear stress measurements past caged-ball, tilting disc, bileaflet, and polyurethane trileaflet mitral valves in an acrylic rigid model of the left ventricle using laser Doppler anemometry. The results indicate that all four prosthetic heart valves studied create at least mildly disturbed flow fields. The effect of the left ventricular geometry on the flow development is to produce a stabilizing vortex which engulfs the entire left ventricular cavity, depending on the orientation of the valve. The measured turbulent shear stress magnitudes for all four valves did not exceed the reported value for hemolytic damage. However, the measured turbulent shear stresses were near or exceeded the critical shear stress reported in the literature for platelet lysis, a known precursor to thrombus formation.  相似文献   

2.
3.
Pulsatile flow dynamics through bileaflet (St Jude and Duromedics), tilting disc (Bjork-Shiley and Omniscience), caged ball (Starr-Edwards), pericardial (Edwards) and porcine (Carpentier-Edwards) mitral valves in a model human left ventricle (LV) were studied. The model human ventricle, obtained from an in situ diastolic casting, was incorporated into a mock circulatory system. Measurements were made at various heart rates and flow rates. These included the transvalvular pressure drop and regurgitation in percent and cm3 beat-1. The effect of valve geometry and the orientation of the valve with respect to the valve annulus was analyzed using a flow visualization technique. Qualitative flow visualization study indicates certain preferred orientations for the tilting disc and bileaflet valve prostheses in order to obtain a smooth washout of flow in the LV chamber.  相似文献   

4.
Left heart catheterization using the transbronchial route to obtain pressures in the left atrium and left ventricle was used successfully in 29 cases with no mortality or morbidity. It was found to be useful in differentiating between mitral stenosis and mitral insufficiency, as well as determining the amount of aortic stenosis present when there was involvement of the aortic valve. The technique was also helpful in determining which is the predominant lesion when there is a disease of the aortic and mitral valves.In two patients in a series of 29, data obtained by left heart catheterization forestalled operation on the basis of a mistaken diagnosis of mitral stenosis when actually no mitral valvular disease was present. In another eight patients, the predominant lesion was found to be mitral stenosis rather than mitral insufficiency as it was thought to be before catheterization. In two patients, who had only systolic murmurs, catheterization revealed mitral stenosis rather than mitral insufficiency. In four patients who were thought to have mixed valvular disease, left heart catheterization showed only aortic valvular disease.  相似文献   

5.
Left heart catheterization using the transbronchial route to obtain pressures in the left atrium and left ventricle was used successfully in 29 cases with no mortality or morbidity. It was found to be useful in differentiating between mitral stenosis and mitral insufficiency, as well as determining the amount of aortic stenosis present when there was involvement of the aortic valve. The technique was also helpful in determining which is the predominant lesion when there is a disease of the aortic and mitral valves. In two patients in a series of 29, data obtained by left heart catheterization forestalled operation on the basis of a mistaken diagnosis of mitral stenosis when actually no mitral valvular disease was present. In another eight patients, the predominant lesion was found to be mitral stenosis rather than mitral insufficiency as it was thought to be before catheterization. In two patients, who had only systolic murmurs, catheterization revealed mitral stenosis rather than mitral insufficiency. In four patients who were thought to have mixed valvular disease, left heart catheterization showed only aortic valvular disease.  相似文献   

6.
ABSTRACT: INTRODUCTION: A parachute mitral valve is defined as a unifocal attachment of mitral valve chordae tendineae independent of the number of papillary muscles. Data from the literature suggests that the valve can be distinguished on the basis of morphological features as either a parachute-like asymmetrical mitral valve or a true parachute mitral valve. A parachute-like asymmetrical mitral valve has two papillary muscles; one is elongated and located higher in the left ventricle. A true parachute mitral valve has a single papillary muscle that receives all chordae, as was present in our patient. Patients with parachute mitral valves during childhood have multilevel left-side heart obstructions, with poor outcomes without operative treatment. The finding of a parachute mitral valve in an adult patient is extremely rare, especially as an isolated lesion. In adults, the unifocal attachment of the chordae results in a slightly restricted valve opening and, more frequently, valvular regurgitation. CASE PRESENTATION: A 40-year-old Caucasian female patient was admitted to a primary care physician due to her recent symptoms of heart palpitation and chest discomfort on effort. Transthoracic echocardiography showed chordae tendineae which were elongated and formed an unusual net shape penetrating into left ventricle cavity. The parasternal short axis view of her left ventricle showed a single papillary muscle positioned on one side in the posteromedial commissure receiving all chordae. Her mitral valve orifice was slightly eccentric and the chordae were converting into a single papillary muscle. Mitral regurgitation was present and it was graded as moderate to severe. Her left atrium was enlarged. There were no signs of mitral stenosis or a subvalvular ring. She did not have a bicuspid aortic valve or coarctation of the ascending aorta. The dimensions and systolic function of her left ventricle were normal. Our patient had a normal body habitus, without signs of heart failure. Her functional status was graded as class I according to the New York Heart Association grading. CONCLUSIONS: A recently published review found that, in the last several decades, there have been only nine adult patients with parachute mitral valve disease reported, of which five had the same morphological characteristics as our patient. This case presentation should encourage doctors, especially those involved in echocardiography, to contribute their own experience, knowledge and research in parachute mitral valve disease to enrich statistical and epidemiologic databases and aid clinicians in getting acquainted with this rare disease.  相似文献   

7.
With the worldwide prevalence of cardiovascular diseases, much attention has been focused on simulating the characteristics of the human heart to better understand and treat cardiac disorders. The purpose of this study is to build a finite element model of the left atrium (LA) that incorporates detailed anatomical features and realistic material characteristics to investigate the interaction of heart tissue and surgical instruments. This model is used to facilitate the design of an endoscopically deployable atrial retractor for use in minimally invasive, robotically assisted mitral valve repair. Magnetic resonance imaging (MRI) scans of a pressurized explanted porcine heart were taken to provide a 3D solid model of the heart geometry, while uniaxial tensile tests of porcine left atrial tissue were conducted to obtain realistic material properties for noncontractile cardiac tissue. A finite element model of the LA was constructed using ANSYS Release 9.0 software and the MRI data. The Mooney-Rivlin hyperelastic material model was chosen to characterize the passive left atrial tissue; material constants were derived from tensile test data. Finite element analysis (FEA) models of a CardioVations Port Access retractor and a prototype endoscopic retractor were constructed to simulate interaction between each instrument and the LA. These contact simulations were used to compare the quality of retraction between the two instruments and to optimize the design of the prototype retractor. Model accuracy was verified by comparing simulated cardiac wall deflections to those measured by MRI. FEA simulations revealed that peak forces of approximately 2.85 N and 2.46 N were required to retract the LA using the Port Access and prototype retractors, respectively. These forces varied nonlinearly with retractor blade displacement. Dilation of the atrial walls and rigid body motion of the chamber were approximately the same for both retractors. Finite element analysis is shown to be an effective tool for analyzing instrument/tissue interactions and for designing surgical instruments. The benefits of this approach to medical device design are significant when compared to the alternatives: constructing prototypes and evaluating them via animal or clinical trials.  相似文献   

8.
Left ventricular flow is intrinsically complex, three-dimensional and unsteady. Its features are susceptible to cardiovascular pathology and treatment, in particular to surgical interventions involving the valves (mitral valve replacement). To improve our understanding of intraventricular fluid mechanics and the impact of various types of prosthetic valves thereon, we have developed a custom-designed versatile left ventricular phantom with anatomically realistic moving left ventricular membrane. A biological, a tilting disc and a bileaflet valve (in two different orientations) were mounted in the mitral position and tested under the same settings. To investigate 3D flow within the phantom, a four-view tomographic particle image velocimetry setup has been implemented. The results compare side-by-side the evolution of the 3D flow topology, vortical structures and kinetic energy in the left ventricle domain during the cardiac cycle. Except for the tilting disc valve, all tested prosthetic valves induced a crossed flow path, where the outflow crosses the inflow path, passing under the mitral valve. The biological valve shows a strong jet with a peak velocity about twice as high compared to all mechanical heart valves, which makes it easier to penetrate deeply into the cavity. Accordingly, the peak kinetic energy in the left ventricle in case of the biological valve is about four times higher than the mechanical heart valves. We conclude that the tomographic particle imaging velocimetry setup provides a useful ground truth measurement of flow features and allows a comparison of the effects of different valve types on left ventricular flow patterns.  相似文献   

9.
刘仕强  张桂敏  刘琪琳  汪华  明波  陈旭 《生物磁学》2011,(18):3488-3490
目的:总结改良Nikaidoh手术治疗右心室双出口(DORV)患者的临床经验,以提高手术疗效。方法:2例先天性心脏病右心室双出口伴肺动脉瓣狭窄行改良Nikaidoh手术,游离主动脉根部及冠状动脉,重建左心室流出道,以带单瓣牛心包片补片重建肺动脉及右心室流出道。结果:术后患者紫绀消失,复查心脏彩超仅有轻度肺动脉瓣关闭不全,未发现左、右心室流出道梗阻,康复出院。结论:采用改良Nikaidoh手术治疗伴肺动脉瓣狭窄的右室双出口,术后可获得良好的血流动力学效果,早期临床结果满意。  相似文献   

10.
This work presents a validation of a fluid-structure interaction computational model simulating the flow conditions in an in vitro mock heart chamber modeling mitral valve regurgitation during the ejection phase during which the trans-valvular pressure drop and valve displacement are not as large. The mock heart chamber was developed to study the use of 2D and 3D color Doppler techniques in imaging the clinically relevant complex intra-cardiac flow events associated with mitral regurgitation. Computational models are expected to play an important role in supporting, refining, and reinforcing the emerging 3D echocardiographic applications. We have developed a 3D computational fluid-structure interaction algorithm based on a semi-implicit, monolithic method, combined with an arbitrary Lagrangian-Eulerian approach to capture the fluid domain motion. The mock regurgitant mitral valve corresponding to an elastic plate with a geometric orifice, was modeled using 3D elasticity, while the blood flow was modeled using the 3D Navier-Stokes equations for an incompressible, viscous fluid. The two are coupled via the kinematic and dynamic conditions describing the two-way coupling. The pressure, the flow rate, and orifice plate displacement were measured and compared with numerical simulation results. In-line flow meter was used to measure the flow, pressure transducers were used to measure the pressure, and a Doppler method developed by one of the authors was used to measure the axial displacement of the orifice plate. The maximum recorded difference between experiment and numerical simulation for the flow rate was 4%, the pressure 3.6%, and for the orifice displacement 15%, showing excellent agreement between the two.  相似文献   

11.
Congenitally corrected transposition is a rare cardiac malformation characterized by the combination of discordant atrioventricular and ventriculo-arterial connections, usually accompanied by other cardiovascular malformations. Incidence has been reported to be around 1/33,000 live births, accounting for approximately 0.05% of congenital heart malformations. Associated malformations may include interventricular communications, obstructions of the outlet from the morphologically left ventricle, and anomalies of the tricuspid valve. The clinical picture and age of onset depend on the associated malformations, with bradycardia, a single loud second heart sound and a heart murmur being the most common manifestations. In the rare cases where there are no associated malformations, congenitally corrected transposition can lead to progressive atrioventricular valvar regurgitation and failure of the systemic ventricle. The diagnosis can also be made late in life when the patient presents with complete heart block or cardiac failure. The etiology of congenitally corrected transposition is currently unknown, and with an increase in incidence among families with previous cases of congenitally corrected transposition reported. Diagnosis can be made by fetal echocardiography, but is more commonly made postnatally with a combination of clinical signs and echocardiography. The anatomical delineation can be further assessed by magnetic resonance imaging and catheterization. The differential diagnosis is centred on the assessing if the patient is presenting with isolated malformations, or as part of a spectrum. Surgical management consists of repair of the associated malformations, or redirection of the systemic and pulmonary venous return associated with an arterial switch procedure, the so-called double switch approach. Prognosis is defined by the associated malformations, and on the timing and approach to palliative surgical care.  相似文献   

12.
目的:总结二尖瓣置换术后左心室破裂2例临床经验教训,方法:回顾性分析我院2006,1.2009,12二尖瓣置换术后左心室破裂2例的临床资料,两例均在监护室里发生突然大出血,紧急输血,输液,机械呼吸,抗休克治疗,并行开胸手术。结果:一例心外修补抢救成功,术后2周顺利出院,一例CPB下心内外修补,因低心排综合症死亡。结论:左心室破裂是二尖瓣置换术最严重的并发症,一旦发生死亡率极高,因此预防,避免其相关因素更关键:  相似文献   

13.
The motion of both mitral cusps and the presence of valvular regurgitation during ventricular contractions were investigated in seven experiments on dogs in which radiopaque markers had been sutured to the cusps and the valve annulus 1-32 wk before the studies. Cineangiograms of the left ventricle were obtained during ventricular ectopic beats, interposed throughout the cardiac cycle (20-99% of cycle length) and during induced variations in the P-R interval (0-200 ms). Mitral regurgitation was observed only during a) weak, early ectopic beats (peak pressure below 34 mmHg) which were incapable of closing the cusps and b) when ventricular contractions suddenly interrupted normal leaflet motion toward the ventricle, during three well-defined periods of diastole (diastolic valve opening, diastolic rebound, and atrial opening). Valve closure following sudden reversal of cusp opening was slow and the leaflets often did not arrive simultaneously at their closed positions. These findings suggest that sudden interruption of leaflet opening by ventricular contractions is an important mechanism of transient mitral regurgitation in the normal heart.  相似文献   

14.
We make the first attempt to construct a qualitative theory covering the whole process of the major part of the first heart sound from an electrical activation to the phonocardiographic observations at the thorax. We calculate the amplitudes and frequencies of the radiated pressures during the isovolumetric contraction period generated by the muscular wall of the left ventricle and by the valves considered as a spherical shell and two-dimensional membranes, respectively. The analysis shows that both the hemodynamic and the valvular theory are able to explain most of the characteristic features of the first heart sound (linear relation between the amplitudes of the radiated pressure and the slope of the left ventricular pressure-time curve; directional polarity of the amplitudes; equidistant frequency peaks with a decline in amplitudes). However, existing magnitudes of the set of physiological parameters involved seems to favour the hemodynamic theory of the first heart sound. The aortic valve can be neglected as a source of sound. The initial conditions (like valve closure velocity), according to our theory, cannot be important. The predicted time-plot and frequency spectrum of the radiated pressure show a general resemblance with the recorded ones. It is essential to have considerably more quantitative acoustic data both for normal and diseased hearts for subsequent theoretical development.  相似文献   

15.
目的:总结改良Nikaidoh手术治疗右心室双出口(DORV)患者的临床经验,以提高手术疗效。方法:2例先天性心脏病右心室双出口伴肺动脉瓣狭窄行改良Nikaidoh手术,游离主动脉根部及冠状动脉,重建左心室流出道,以带单瓣牛心包片补片重建肺动脉及右心室流出道。结果:术后患者紫绀消失,复查心脏彩超仅有轻度肺动脉瓣关闭不全,未发现左、右心室流出道梗阻,康复出院。结论:采用改良Nikaidoh手术治疗伴肺动脉瓣狭窄的右室双出口,术后可获得良好的血流动力学效果,早期临床结果满意。  相似文献   

16.
Estimation of regional tissue stresses in the functioning heart valve remains an important goal in our understanding of normal valve function and in developing novel engineered tissue strategies for valvular repair and replacement. Methods to accurately estimate regional tissue stresses are thus needed for this purpose, and in particular to develop accurate, statistically informed means to validate computational models of valve function. Moreover, there exists no currently accepted method to evaluate engineered heart valve tissues and replacement heart valve biomaterials undergoing valvular stresses in blood contact. While we have utilized mitral valve anterior leaflet valvuloplasty as an experimental approach to address this limitation, robust computational techniques to estimate implant stresses are required. In the present study, we developed a novel numerical analysis approach for estimation of the in-vivo stresses of the central region of the mitral valve anterior leaflet (MVAL) delimited by a sonocrystal transducer array. The in-vivo material properties of the MVAL were simulated using an inverse FE modeling approach based on three pseudo-hyperelastic constitutive models: the neo-Hookean, exponential-type isotropic, and full collagen–fiber mapped transversely isotropic models. A series of numerical replications with varying structural configurations were developed by incorporating measured statistical variations in MVAL local preferred fiber directions and fiber splay. These model replications were then used to investigate how known variations in the valve tissue microstructure influence the estimated ROI stresses and its variation at each time point during a cardiac cycle. Simulations were also able to include estimates of the variation in tissue stresses for an individual specimen dataset over the cardiac cycle. Of the three material models, the transversely anisotropic model produced the most accurate results, with ROI averaged stresses at the fully-loaded state of  432.6±46.5 kPa and 241.4±40.5 kPa in the radial and circumferential directions, respectively. We conclude that the present approach can provide robust instantaneous mean and variation estimates of tissue stresses of the central regions of the MVAL.  相似文献   

17.
Limited knowledge exists regarding the forces which act on devices implanted to the heart's mitral valve. Developing a transducer to measure the peak force magnitudes, time rates of change, and relationship with left ventricular pressure will aid in device development. A novel force transducer was developed and implanted in the mitral valve annulus of an ovine subject. In the post-cardioplegic heart, septal-lateral and transverse forces were continuously measured for cardiac cycles reaching a peak left ventricular pressure of 90 mmHg. Each force was seen to increase from ventricular diastole and found to peak at mid-systole. The mean change in septal-lateral and transverse forces throughout the cardiac cycle was 4.4±0.2 N and 1.9±0.1 N respectively. During isovolumetric contraction, the septal-lateral and transverse forces were found to increase at peak rate of 143±8 N/s and 34±9 N/s, respectively. Combined, this study provides the first quantitative assessment of septal-lateral and transverse forces within the contractile mitral annulus. The developed transducer was successful in measuring these forces whose methods may be extended to future studies. Upon additional investigation, these data may contribute to the safer development and evaluation of devices aimed to repair or replace mitral valve function.  相似文献   

18.
In patients with aortic stenosis, the left ventricular afterload is determined by the degree of valvular obstruction and the systemic arterial system. We developed an explicit mathematical model formulated with a limited number of independent parameters that describes the interaction among the left ventricle, an aortic stenosis, and the arterial system. This ventricular-valvular-vascular (V(3)) model consists of the combination of the time-varying elastance model for the left ventricle, the instantaneous transvalvular pressure-flow relationship for the aortic valve, and the three-element windkessel representation of the vascular system. The objective of this study was to validate the V(3) model by using pressure-volume loop data obtained in six patients with severe aortic stenosis before and after aortic valve replacement. There was very good agreement between the estimated and the measured left ventricular and aortic pressure waveforms. The total relative error between estimated and measured pressures was on average (standard deviation) 7.5% (SD 2.3) and the equation of the corresponding regression line was y = 0.99x - 2.36 with a coefficient of determination r(2) = 0.98. There was also very good agreement between estimated and measured stroke volumes (y = 1.03x + 2.2, r(2) = 0.96, SEE = 2.8 ml). Hence, this mathematical V(3) model can be used to describe the hemodynamic interaction among the left ventricle, the aortic valve, and the systemic arterial system.  相似文献   

19.
目的:总结同期行冠状动脉旁路移植(CABG)和心脏瓣膜置换术治疗冠心病合并心脏瓣膜病的临床经验。方法:回顾性分析我院收治的41例接受冠状动脉旁路移植同期行心脏瓣膜置换术的冠心病合并心脏瓣膜病患者的临床资料,对手术方法、主要并发症和术后处理方法进行分析总结。结果:41例患者中,行二次开胸4例(9.76%),应用IABP 2例(4.88%),发生低心排综合征6例(14.63%)、肾功能不全6例(14.63%)、肺功能不全7例(17.07%)、脑合并症1例(2.44%)、胸腔积液4例(9.77%),死亡6例(13.63%),其余患者康复出院。结论:CABG同期行心脏瓣膜置换术治疗冠心病合并心脏瓣膜病的近期疗效满意。术前改善心功能,成熟的手术技术,完全的心肌再血管化,良好的心肌保护,停机困难者尽早应用主动脉内球囊反搏(IABP)及加强术后处理是提高CABG同期行心脏瓣膜置换术疗效的重要措施。  相似文献   

20.
The majority of patients with acquired valvular heart disease have severe damage to valves which is not amenable to repair but can now be treated by valve replacement with an acceptable mortality and morbidity.The caged ball or disc valve is widely used and is proving clinically satisfactory for cardiac valve replacement. Thromboembolism is the significant complication. With improvement in technique the incidence of infection, detachment and other complications has been reduced.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号