首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study reports a microfluidic chip integrated with an arrayed immunoassay for surface plasmon resonance (SPR) phase imaging of specific bio-samples. The SPR phase imaging system uses a surface-sensitive optical technique to detect two-dimensional (2D) spatial phase variation caused by rabbit immunoglobulin G (IgG) adsorbed on an anti-rabbit IgG film. The microfluidic chip was fabricated by using micro-electro-mechanical-systems (MEMS) technology on glass and polydimethylsiloxane (PDMS) substrates to facilitate well-controlled and reproducible sample delivery and detection. Since SPR detection is very sensitive to temperature variation, a micromachine-based temperature control module comprising micro-heaters and temperature sensors was used to maintain a uniform temperature distribution inside the arrayed detection area with a variation of less than 0.3 degrees C. A self-assembled monolayer (SAM) technique was used to pattern the surface chemistry on a gold layer to immobilize anti-rabbit IgG on the modified substrates. The microfluidic chip is capable of transporting a precise amount of IgG solution by using micropumps/valves to the arrayed detection area such that highly sensitive, highly specific bio-sensing can be achieved. The developed microfluidic chips, which employed SPR phase imaging for immunoassay analysis, could successfully detect the interaction of anti-rabbit IgG and IgG. The interactions between immobilized anti-rabbit IgG and IgG with various concentrations have been measured. The detection limit is experimentally found to be 1 x 10(-4)mg/ml (0.67 nM). The specificity of the arrayed immunoassay was also explored. Experimental data show that only the rabbit IgG can be detected and the porcine IgG cannot be adsorbed. The developed microfluidic system is promising for various applications including medical diagnostics, microarray detection and observing protein-protein interactions.  相似文献   

2.
Liu Z  Yang L  Liu L  Chong X  Guo J  Ma S  Ji Y  He Y 《Biosensors & bioelectronics》2011,30(1):180-187
With the development of the microarray technology, demands for array detection techniques become higher and higher. For many microarrays, several biomolecular interactions occur simultaneously and the interplay of various factors that affect these interactions remains poorly understood. Detecting such interactions with a single technique can often be a difficult and complicated process. In this work we propose a combined technique which enables simultaneous angle-interrogation surface plasmon resonance (SPR) sensing and hyperspectral fluorescence imaging. This tandem technique offers two-dimensional imaging of the whole array plane. The refractive index information obtained from SPR sensing and the physicochemical properties obtained from fluorescence imaging provide a comprehensive analysis of biological events on the array-chip. In addition, SPR and fluorescence detection techniques confirm each other in experimental results to exclude false-positive or false-negative cases. In terms of SPR sensing performance, the refractive index resolution is 3.86 × 10−6 refractive index units (RIU), and the detection limit is 104 cfu/ml of Escherichia coli bacteria. The resolving power and detection sensitivity of fluorescence imaging are approximately 20 μm and 0.61 fluors/μm2, respectively. Finally, two model experiments, detecting the DNA hybridization and biotin–avidin interactions respectively, demonstrate the biomedical application of this system.  相似文献   

3.
Lectin microarrays have emerged as a novel platform for glycan analysis during recent years. Here, we have combined surface plasmon resonance imaging (SPRi) with the lectin microarray for rapid and label-free profiling of stem cells. In this direction, 40 lectins from seven different glyco-binding motifs and three different cell lines—mouse embryonic stem cells (mESCs), mouse-induced pluripotent stem cells (miPSCs), and mouse embryonic fibroblast stem cells (MEFs)—were used. Pluripotent mouse stem cells were clearly distinguished from non-pluripotent stem cells. Eight lectins—DBA, MAL, PHA_E, PHA_L, EEL, AAL, PNA, and SNA—generated maximal value to define pluripotency of mouse stem cells in our experiments. The discriminant function based on lectin reactivities was highly accurate for the determination of stem cell pluripotency. These results suggested that glycomic analysis of stem cells leads to a novel comprehensive approach for quality control in cell-based therapy and regenerative medicine.  相似文献   

4.
A surface plasmon resonance array biosensor based on spectroscopic imaging   总被引:6,自引:0,他引:6  
We have developed a multi-element transduction system which combines conventional SPR spectroscopy with one-dimensional SPR microscopy to create an effective platform for monitoring binding events on macro- or micro-patterned receptor arrays created on disposable sensor chips. This creates an effective platform for monitoring simultaneous binding events on each of the regions patterned with the receptors. This system has been specifically designed with commercially available components to allow relatively easy duplication. Furthermore, this system can use a proven, simple method to compensate for changes in the bulk index of refraction of the solution containing the analytes due to changes in temperature or solute concentration with simple modifications to the sensor chips alone. Preliminary results demonstrate how this system can be used to monitor several independent biospecific binding events simultaneously.  相似文献   

5.
In this study we examined the possibilities of implementing direct and competitive immunoassay formats for small and large molecule detection on a microarray, using IBIS imaging surface plasmon resonance (iSPR) system. First, IBIS iSPR optics performance was evaluated. Using a glycerol calibration curve on underivatized surface we observed high baseline variability, but uniform and robust sensitivity between hundred regions of interest. Further on, a direct immunoassay for bovine IgG detection and a competitive immunoassay for gentamicin and neomycin were developed. The direct immunoassay for bovine IgG detection in a microarray format showed poor sensitivity in comparison to the assay performed in Biacore 3000, due to low immobilization efficiency on spots. The competitive immunoassay for parallel gentamicin and neomycin detection in a microarray format displayed sensitivity in the ngmL(-1) range, comparable with the sensitivity achieved in Biacore 3000 and in the range of maximum residue limits in milk, established in the European Union. We expect that, utilization of the IBIS iSPR system for food analysis, by screening high and low molecular weight compounds, will allow rapid and simultaneous detection of various ingredients and contaminants, providing the end-user with a detailed food profile. However, assay transfer from conventional SPR biosensors to the imaging microarray platform also presents new challenges, such as sufficient immobilization on spots, that must be addressed in future studies.  相似文献   

6.
Jin W  Lin X  Lv S  Zhang Y  Jin Q  Mu Y 《Biosensors & bioelectronics》2009,24(5):1266-1269
A practical and simple DNA sensor based on surface plasmon resonance (SPR) had been developed to determine apoptosis-associated genes, bcl-2 and bax. This SPR sensor was designed on the basis of simultaneous multi-wavelength detection. The complementary sequences of bcl-2 or bax oligonucleotide labeled with biotin were used as the probes. Biotin-avidin system was used to immobilize the bio-DNA on the sensor surface. The assembling processes and conditions for the DNA sensor were examined. The SPR sensor could be used to monitor the process of the immobility of the bio-DNA and DNA hybridization in real-time. The determination range of bcl-2 and bax oligonucleotide (20 bases) were 50-400 ng/mL. The determination range of polymerase chain reaction (PCR) product of bcl-2 (405 bases) was 5-60 ng/mL and PCR product of bax (538 bases) was 5-40 ng/mL. The stability, reversibility and specificity of the DNA sensor were also investigated. It was found from the experiment that the sensor could be applied for a quite long time (about 90 times). The relative standard deviation (R.S.D.) for determination oligonucleotides and PCR products of bcl-2 were 1.2 and 1.3%, respectively. The interference of noncomplementary DNA sequence with the determination of DNA was examined and it was found that noncomplementary 20-mer and 21-mer DNA (p53 and p21) do not affect the determination of bcl-2 or bax. This device could be used to study apoptosis and signal transduction routine genes. The sensor was shown to be of simplicity, sensitivity, selectivity, rapid response and cost effectiveness.  相似文献   

7.
The advances in genomics and proteomics have unveiled an exhaustive catalogue of biomarkers that can potentially be used as diagnostic and prognostic indicators of genetic and infectious diseases. Current thrust in biosensor development is towards rapid, real-time, label-free and highly sensitive detection of the indicative biomarkers. While surface plasmon resonance imaging (SPRi) biosensors could potentially be the best suited candidate for biomarker-based diagnosis, important milestones need to be reached. Commercially available SPRi instrumentation is currently limited by the flow-cell technology to serial-sample processing and has limited sensitivity for the detection of markers present at low concentration. In this paper, we have implemented an approach to enhance sample handling and increase the sensitivity of the SPRi detection technique. We have developed a digital microfluidic platform with an integrated nanostructured biosensor interface that allows for rapid, ultra-low volume, sensitive, and automated on-chip SPRi detection of DNA hybridization reactions. Through the exploitation of electromagnetic properties of nanofabricated periodic gold nanoposts, SPRi signal was increased by 200% with the estimated limit of detection of 500 pM (90 attomoles). Using the versatile fluidic manipulation provided by the digital microfluidics, rapid and parallel target identification was achieved on multiple array elements within 1 min using 180 nL sample volume. By delivering multiple target analytes in individually addressable low volume droplets, without external pumps and fluidic interconnects, the overall assay time, cost and complexity was reduced. The proposed platform allows extreme versatility in the manipulation of precious low volume samples which makes this technology very suitable for diagnostic applications.  相似文献   

8.
This paper reports the application of differential phase surface plasmon resonance (SPR) imaging in two-dimensional (2D) protein biosensor arrays. Our phase imaging approach offers a distinct advantage over the conventional angular SPR technique in terms of utilization efficiency of optical sensor elements in the imaging device. In the angular approach, each biosensor site in the biosensor array requires a linear array of optical detector elements to locate the SPR angular dip. The maximum biosensor density that a two-dimensional imaging device can offer is a one-dimensional SPR biosensor array. On the other hand, the phase-sensitive SPR approach captures data in the time domain instead of the spatial domain. It is possible that each pixel in the captured interferogram represents one sensor site, thus offering high-density two-dimensional biosensor arrays. In addition, our differential phase approach improves detection resolution through removing common-mode disturbances. Experimental results demonstrate a system resolution of 8.8 x 10(-7)RIU (refractive index unit). Real-time monitoring of bovine serum albumin (BSA)/anti-BSA binding interactions at various concentration levels was achieved using a biosensor array. The detection limit was 0.77 microg/ml. The reported two-dimensional SPR biosensor array offers a real-time and non-labeling detection tool for high-throughput protein array analysis. It may find promising applications in protein therapeutics, drug screening and clinical diagnostics.  相似文献   

9.
10.
Grating-coupled surface plasmon resonance (GCSPR) is a method for the accurate assessment of analyte in a multiplexed format using small amounts of sample. In GCSPR, the analyte is flowed across specific receptors (e.g. antibodies or other proteins) that have been immobilized on a sensor chip. The chip surface is illuminated with p-polarized light that couples to the gold surface's electrons to form a surface plasmon. At a specific angle of incidence, the GCSPR angle, the maximum amount of coupling occurs, thus reducing the intensity of reflected light. Shifts in the GCSPR angle can be correlated with refractive index increases following analyte capture by chip-bound receptors. Because regions of the chip can be independently analyzed, this system can assess 400 interactions between analyte and receptor on a single chip. We have used this label-free system to assess a number of molecules of immunological interest. GCSPR can simultaneously detect an array of cytokines and other proteins using the same chip. Moreover, GCSPR is also compatible with assessments of antigen expression by intact cells, detecting cellular apoptosis and identifying T cells and B cells. This technology represents a powerful new approach to the analysis of cells and molecular constituents of biological samples.  相似文献   

11.
We report the construction and characterization of a new compact surface plasmon resonance imaging instrument. Surface plasmon resonance imaging is a versatile technique for detection, quantification and visualization of biomolecular binding events which have spatial structure. The imager uses a folded light path, wide-field optics and a tilted detector to implement a high performance optical system in a volume 7 in. x 4 in. x 2 in. A bright diode light source and an image detector with fast frame rate and integrated digital signal processor enable real-time averaging of multiple images for improved signal-to-noise ratio. Operating angle of the imager is adjusted by linear translation of the light source. Imager performance is illustrated using resolution test targets, refractive index test solutions, and competition assays for the antiepileptic drug phenytoin. Microfluidic flowcells are used to enable simultaneous assay of three sample streams. Noise level of refractive index measurements was found to decrease proportional to the square root of the number of pixels averaged, reaching approximately 5 x 10(-7) refractive index units root-mean-square for 160 x 120 pixels image regions imaged for 1s. The simple, compact construction and high performance of the imager will allow the device to be readily applied to a wide range of applications.  相似文献   

12.
A method for microbial cell surface fingerprinting using surface plasmon resonance (SPR) is suggested. Four different Escherichia coli mutants have been used as model cells. Cell surface fingerprints were generated by registration of the interaction between the cell mutants and four different surfaces, with different physical and chemical properties, when a cell suspension was flown over the surface. Significant differences in fingerprint pattern between some of the mutants were observed. At the same time, the physical properties of the cell surfaces were determined using microelectrophoresis, contact angle measurements and aqueous two-phase partitioning and compared to the SPR fingerprints. The generated cell surface fingerprints and the physical property data were evaluated with multivariate data analysis that showed that the cells were separated into individual groups in a similar way using principal component analysis plots (PCA).  相似文献   

13.
A surface plasmon resonance (SPR) based natural glycan microarray was developed for screening of interactions between glycans and carbohydrate-binding proteins (CBPs). The microarray contained 144 glycan samples and allowed the real-time and simultaneous screening for recognition by CBPs without the need of fluorescent labeling. Glycans were released from their natural source and coupled by reductive amination with the fluorescent labels 2-aminobenzamide (2AB) or anthranilic acid (AA) followed by high-performance liquid chromatography (HPLC) fractionation making use of the fluorescent tag. The released and labeled glycans, in addition to fluorescently labeled synthetic glycans and (neo)glycoproteins, were printed on an epoxide-activated chip at fmol amounts. This resulted in covalent immobilization, with the epoxide groups forming covalent bonds to the secondary amine groups present on the fluorescent glycoconjugates. The generated SPR glycan array presented a subset of the glycan repertoire of the human parasite Schistosoma mansoni. In order to demonstrate the usefulness of the array in the simultaneous detection of glycan-specific serum antibodies, the anti-glycan antibody profiles from sera of S. mansoni-infected individuals as well as from non-endemic uninfected controls were recorded. The SPR screening was sensitive for differences between infection sera and control sera, and revealed antibody titers and antibody classes (IgG or IgM). All SPR analyses were performed with a single SPR array chip, which required regeneration and blocking of the chip before the application of a serum sample. Our results indicate that SPR-based arrays constructed from glycans of natural or synthetic origin, pure or as mixture, can be used for determining serum antibody profiles as possible markers for the infection status of an individual.  相似文献   

14.
In this study, we fabricated a novel variable wavelength surface plasmon resonance (SPR) sensor, which detects resonance conditions such as a maximum attenuation wavelength, measuring change of microscopic refractive index. Such a change was measured to detect a salmonella antigen–antibody reaction and a penicillinase–penicillin reaction. Our experiments were performed after immobilizing a salmonella antibody on the sensor chip. We measured the shift in resonant wavelength during the antigen–antibody reaction for 30 min by injecting 5 × 107 cells/ml concentration of salmonella antigen solution into the sample chamber. Also, after immobilizing penicillinase on the sensor chip, we measured the shift in resonant wavelength during the reaction. Penicillin solution at 10 mM was injected into the sample chamber. The shift of resonant wavelength for each experiment was measured using a white light source, multimode optical fiber, a part of sensor chip and an optical spectrum analyzer.As a result, the resonant wavelength shifted about 0.26 nm/min owing to the salmonella antibody–antigen reaction. Thus, we could detect the change in wavelength (0.8 nm/min) through the interaction of penicillin and penicillinase for 15 min using variable wavelength SPR sensor.  相似文献   

15.
A surface plasmon resonance (SPR) imaging system was constructed and used to detect the affinity-tagged recombinant proteins expressed in Escherichia coli. With regards to model proteins, the hexahistidine-ubiquitin-tagged human growth hormone (His(6)-Ub-hGH), glutathione S-transferase-tagged human interleukin-6 (GST-hIL6), and maltose-binding protein-tagged human interleukin-6 (MBP-hIL6) expressed in E. coli were analyzed. The cell lysates were spotted on gold thin films coated with 11-mercaptoundecanol (MUOH)/dextran derivatized with Ni(II)-iminodiacetic acid (IDA-Ni(II)), glutathione, or cyclodextrin. After a brief washing of the gold chip, SPR imaging measurements were carried out in order to detect the bound affinity-tagged fusion proteins. Using this new approach, rapid high-throughput expression analysis of the affinity-tagged proteins were obtained. The SPR imaging protein chip system used to measure the expression of affinity-tagged proteins in a high-throughput manner is expected to be an attractive alternative to traditional laborious and time-consuming methods, such as SDS-polyacrylamide gel electrophoresis (SDS-PAGE) and Western blots.  相似文献   

16.
Cholesterol oxidase (ChOx) has been covalently immobilized onto 1-fluoro-2-nitro-4-azidobenzene (FNAB) modified poly-(3-hexylthiophene) (P3HT) self-assembled monolayer (SAM) onto gold coated glass plates. These ChOx/FNAB/P3HT/Au bio-electrodes have been characterized using contact angle (CA) measurements, UV-vis spectroscopy, electrochemical impedance technique, cyclic voltammetric technique and atomic force microscopic (AFM) technique, respectively. The ChOx/FNAB/P3HT/Au bio-electrodes were utilized for the estimation of cholesterol concentration in standard solutions using surface plasmon resonance (SPR) technique. It is shown that this SPR biosensor has linearity from 50 to 500 mg/dl of cholesterol in solution with detection limit of 50 mg/dl, sensitivity of 1.0 4 m degrees /(mg dl), reusability of around 15 times and a shelf-life of about 10 weeks when stored at 4 degrees C.  相似文献   

17.
We propose the combination of surface plasmon resonance (SPR) with living cells as a biosensing method. Our detection scheme is based on the premise that cellular activity induced by external agents is often associated with changes in cellular morphology, which in turn should lead to a variation of the effective refractive index at the interface between the cell membrane and the metal layer. We monitored surface plasmon resonance signals originating from a gold surface coated with cells on a custom apparatus after injection of various agents known to influence cellular activity and morphology. Specifically, we evaluated three types of stimulation: response to an endotoxin (lipopolysaccharides), a chemical toxin (sodium azide) and a physiological agonist (thrombin). A comparison with phase contrast microscopy reveals that SPR signal variations are associated with the induction of cell death for lipopolysaccharides treatment and a contraction of the cell body for sodium azide. Thrombin-induced cellular response shows a rapid decrease of the measured laser reflectance over 5min followed by a return to the original value. For this treatment, phase contrast micrographs relate the first phase of the SPR variation to cell contraction and increase of the intercellular gaps, whereas the recovery phase can be associated with a spreading of the cell on the sensing surface. Hence, the SPR signal is very consistent with the cellular response normally observed for these treatments. This confirms the validity of the biosensing method, which could be applied to a large variety of cellular responses involving shape remodeling induced by external agents.  相似文献   

18.
Surface plasmon resonance imaging systems, such as Flexchip from Biacore, are capable of monitoring hundreds of reaction spots simultaneously within a single flow cell. Interpreting the binding kinetics in a large-format flow cell presents a number of potential challenges, including accounting for mass transport effects and spot-to-spot sample depletion. We employed a combination of computer simulations and experimentation to characterize these effects across the spotted array and established that a simple two-compartment model may be used to accurately extract intrinsic rate constants from the array under mass transport-limited conditions. Using antibody systems, we demonstrate that the spot-to-spot variability in the binding kinetics was <9%. We also illustrate the advantage of globally fitting binding data from multiple spots within an array for a system that is mass transport limited.  相似文献   

19.
We present an analysis of hybridization experiments on a DNA chip studied by surface plasmon resonance imaging. The reaction constants at various temperatures and for different probe lengths are obtained from Langmuir isotherms and hybridization kinetics. The melting curves from temperature scans are also obtained without any labeling of the targets. The effects of the probe length on the hybridization thermodynamics, deduced from the temperature dependence of the reaction constants as well as from the melting curves, suggest dispersion in the length of the hybridization segments of the probes accessible to the targets. Those are, however, sufficient to suggest efficient point mutation detection from temperature scans.  相似文献   

20.
Arraying proteins is often more challenging than creating oligonucleotide arrays. Protein concentration and purity can severely limit the capacity of spots created by traditional pin and ink jet printing techniques. To improve protein printing methods, we have developed a three-dimensional microfluidic system to deposit protein samples within discrete spots (250-microm squares) on a target surface. Our current technology produces a 48-spot array within a 0.5 x 1 cm target area. A chief advantage of this method is that samples may be introduced in continuous flow, which makes it possible to expose each spot to a larger volume of sample than would be possible with standard printing methods. Using Biacore Flexchip (Biacore AB) surface plasmon resonance array-based biosensor as a chip reader, we demonstrate that the microfluidic printer is capable of spotting proteins that are dilute (<0.1 microg/ml) and contain high concentrations of contaminating protein (>10,000-fold molar excess). We also show that the spots created by the microfluidic printer are more uniform and have better-defined borders than what can be achieved with pin printing. The ability to readily print proteins using continuous flow will help expand the application of protein arrays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号