首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Inhalation of airborne microorganisms and organic dust is an occupational concern among workers in agricultural industries. Airborne microorganisms and particulate matter samples were collected from poultry house, flourmill, textile, and food industry sites by use of liquid impinger and gravimetric samplers. Particulate matter concentrations were recorded at median concentrations of 1.56, 1.92, 4.39, and 0.7 mg/m3 in the occupied poultry house, textile, flourmill, and food indoor working environments, respectively. The highest median particulate matter concentration (27.9 mg/m3) was detected at the flourmill’s stack site. The highest median indoor concentration of culturable airborne bacteria (6.23 × 105 CFU/m3) was found at the occupied poultry-house site and the lowest concentration (4.6 × 103 CFU/m3) was found at the food industry site. The highest median indoor concentration of culturable airborne fungi (3.15 × 104 CFU/m3) was found at the flourmill site whereas the lowest (1.24 × 103 CFU/m3) was found at the textile industry site. Bacillus and Staphylococcus were the predominant Gram-positive bacteria whereas Acinetobacter and Klebsiella were the predominant Gram-negative bacteria. Escherichia coli and Salmonella were only detected in the indoor air at the poultry house site. Aspergillus flavus, Aspergillus niger, Penicillium, and yeast were the predominant fungal types at flourmill, textile, food industry, and poultry house, respectively. Workers were continuously exposed to airborne microorganisms at a median value of 104 CFU/m3 in all the industries studied.  相似文献   

2.
Thailand border market is where the local Thais, Cambodians, Laotians, and Burmeses exchange their goods and culture at the border checkpoints. It is considered to be the source of aerial disease transmission especially for foreigners because it is always very crowded with people from all walks of life. Unhealthy air quality makes this area high risk of spread of airborne diseases. This study assessed airborne concentrations of bacteria and fungi in a border market to improve exposure estimates and develop efficient control strategies to reduce health risk. The density and distribution of airborne bacteria and fungi were investigated in the Chong Chom border market in Surin Province, Thailand. Eighteen air sampling sites were taken from outdoors and various work environments including indoor footpaths, wooden handicraft shops, electronic shops, the secondhand clothing shops, and fruit market areas. Exposed Petri plate method and liquid impinger sampler were used for sampling at the breathing zone, 1.5 m above the floor level, during weekend and holiday. Meteorological factors such as relative humidity, temperature, and light intensity were collected by portable data logger. The relative humidity was 67–73%, and temperature 29–33°C, and light varied between 18 and 270 Lux m−2. Gram-positive and Gram-negative bacteria were found at a mean value of 104 CFU m−3, and airborne fungi of 103 CFU m−3 were recorded. The highest concentration of culturable airborne microorganisms was found along the indoor footpath (9.62 × 104 CFU m−3 and 750.00 CFU/plate/h for impingement and sedimentation methods, respectively), the fruit market area (7.86 × 104 CFU m−3 and 592.42 CFU/plate/h for impingement and sedimentation methods, respectively), and the secondhand clothing shop (4.59 × 103 CFU m−3 and 335.42 CFU/plate/h for impingement and sedimentation methods, respectively) for Gram-positive bacteria, Gram-negative bacteria, and fungi, respectively. The lowest concentration of Gram-positive bacteria, Gram-negative bacteria, and fungi was found only at the outdoor area at 1.53 × 104 CFU m−3, 0.93 × 104 CFU m−3 and 0.80 × 103 CFU m−3 by means of impingement method and 136.67 CFU/plate/h, 69.25 CFU/plate/h, and 62.00 CFU/plate/h by means of sedimentation methods for Gram-positive bacteria, Gram-negative bacteria, and fungi, respectively. The most frequently present airborne bacteria were identified as Bacillus, Corynebacteria, Diplococcus, Micrococcus, Acinetobacter, Alcaligenes, Enterobacter, and spore former rods. Acremonium, Aspergillus, Cladosporium, Penicillium, and Sporotrichum were the most frequently found aerosol fungi genera. The distribution of airborne microorganisms correlated with relative humidity and light factors based on principal component analysis. In conclusion, the border market is a potential source of aerial disease transmission and a various hazards of bioaerosols for workers, consumers, sellers, and tourists. The bioaerosol concentration exceeded the standard of occupational exposure limit. Many major indicators of allergenic and toxigenic airborne bacteria and fungi, Acinetobacter, Enterobacter, Pseudomonas, Cladosporium, Alternaria, Aspergillus, and Penicillium, were found in the various market environments.  相似文献   

3.
This study quantified the levels of airborne microorganisms in six swine farms with more than 10,000 pigs in subtropical Taiwan. We evaluated breeding, growing, and finishing stalls, which were primarily open-air buildings, as well as partially enclosed farrowing and nursery piggeries. Airborne culturable bacteria, gram-negative bacteria, and fungi were placed on appropriate media by using an all-glass impinger or single-stage Andersen microbial sampler. Results showed that mean concentrations of culturable bacteria and gram-negative bacteria were 3.3 × 105 and 143.7 CFU/m3, respectively. The concentration of airborne culturable fungi was about 103 CFU/m3, with Cladosporium the predominant genus. The highest airborne levels of culturable bacteria and gram-negative bacteria were identified in the finishing units. The air of the nursery stalls was the least contaminated with culturable and gram-negative bacteria. Irregular and infrequent cleaning, high pig density, no separation of wastes from pen floors, and accumulation of water as a result of the processes for cleaning and reducing pig temperature possibly compromise the benefits of the open characteristic of the finishing units with respect to airborne bacterial concentration.  相似文献   

4.
Numbers of airborne microorganisms, fungi, Gram-negative bacteria, thermophilic microorganisms, endotoxins and dust have been monitored in resource recovery plants and composting plants. The work is still in progress, so this paper decribes only preliminary results. Only low levels (< 15 ng m?3) of endotoxins were found at all locations. Levels of microorganisms, fungi, Gram-negative bacteria and dust changed with quality of waste, activity in the plant etc. Levels of airborne microorganisms, endotoxins and dust could be considerably decreased in resource recovery plants if only waste of good quality, e.g. presorted materials, is handled. For composting plants the highest levels of airborne microorganisms were found during aeration, especially by indoor composting where levels of 8.3 × 105 CFU of mesophilic microorganisms were found.  相似文献   

5.
Alfresco (def. clean, outdoor) airborne bacteria were collected with a commercially available wet-cyclone bioaerosol sampler to demonstrate its use, sample processing and resultant observations of total and culturable bacteria in mid-summer in the mid-Willamette River Valley, OR. Some critiques of the system are given. The maximum and minimum total and culturable airborne bacterial concentrations in the samples were 5.9 × 105 and 8.8 × 102 cells m−3, and 1.3 × 104 and 3.1 CFU m−3, respectively. What is thought to be a diurnal cycle was also observed for both fractions with highest concentrations during the day and lowest at dawn and dusk. The culturable bacteria as a percentage of the total, was maximal at mid-day (≈ 3%) and minimal at early morning and late evening (≈ 0.5–2%). Contrarily, the total bacteria in the downwind dust plume of a grass seed combine was 2.9 × 106 cells m−3 and of these approximately 73% were culturable, a much greater culturable percentage than found in the alfresco outdoor atmosphere.  相似文献   

6.
According to Council Directive 90/679/EEC on the protection of workers from risks related to exposure to biological agents at work, nature, degree and duration of workers’ exposure to microorganisms must be determined. This directive has already been implemented in waste and wastewater management. The present case study investigates concentration and composition of microorganisms in a poultry slaughterhouse in the State of Styria, Austria. From June to November 2002, measurements were conducted at the sampling sites ‘moving rail’ and ‘gall bladder separation’ using the Andersen six stage viable cascade impactor and the SKC BioSampler. The results of this study were compared with other previous studies which were carried out using the same device (ACFM) and the same measurement methods. At the processing area of the ‘moving rail’, the median concentration of airborne mesophilic bacteria was 1.7×106 CFU/m3 which is 8000 times higher than the background concentration of residential areas (approx. 210 CFU/m3). The airborne microorganisms concentration was 1.7×104 CFU/m3 at composting plants which is 100 times lower than at a workplace of a poultry slaughterhouse. The study shows that poultry slaughterhouse employees are exposed to high concentrations of airborne microorganisms throughout the entire work time without using a respiratory protective device. For the protection of employees against airborne biological agents, relevant measures should be introduced to this field of work.  相似文献   

7.
The influence of sample-collection-time on the recovery of culturable airborne microorganisms using a low-flow-rate membrane-filtration unit and a high-flow-rate liquid impinger were investigated. Differences in recoveries were investigated in four different atmospheric environments, one mid-oceanic at an altitude of ~10.0 m, one on a mountain top at an altitude of ~3,000.0 m, one at ~1.0 m altitude in Tallahassee, Florida, and one at ~1.0 m above ground in a subterranean-cave. Regarding use of membrane filtration, a common trend was observed: the shorter the collection period, the higher the recovery of culturable bacteria and fungi. These data also demonstrated that lower culturable counts were common in the more remote mid-oceanic and mountain-top atmospheric environments with bacteria, fungi, and total numbers averaging (by sample time or method categories) <3.0 colony-forming units (CFU) m−3. At the Florida and subterranean sites, the lowest average count noted was 3.5 bacteria CFU m−3, and the highest averaged 140.4 total CFU m−3. When atmospheric temperature allowed use, the high-volume liquid impinger utilized in this study resulted in much higher recoveries, as much as 10× greater in a number of the categories (bacterial, fungal, and total CFU). Together, these data illustrated that (1) the high-volume liquid impinger is clearly superior to membrane filtration for aeromicrobiology studies if start-up costs are not an issue and temperature permits use; (2) although membrane filtration is more cost friendly and has a ‘typically’ wider operational range, its limits include loss of cell viability with increased sample time and issues with effectively extracting nucleic acids for community-based analyses; (3) the ability to recover culturable microorganisms is limited in ‘extreme’ atmospheric environments and thus the use of a ‘limited’ methodology in these environments must be taken into account; and (4) the atmosphere culls, i.e., everything is not everywhere.  相似文献   

8.
Bioaerosol concentrations inside one naturally ventilated and one mechanically ventilated swine finishing barn were assessed by sampling air using membrane filtration and impaction (six-stage Andersen sampler), and assayed by culture method. The barns, located on the same commercial farm in northeast Kansas, did not show any significant difference (p > 0.05) in concentrations of total and respirable airborne microorganisms. The overall mean total concentrations inside the two barns were 6.6 × 104 colony forming units (CFU)/m3 (SD = 3.8 × 104 CFU/m3) as measured by filtration and 8.6 × 104 CFU/m3 (SD = 5.1 × 104 CFU/m3) by impaction. The overall mean respirable concentrations were 9.0 × 103 CFU/m3 (SD = 4.1 × 103 CFU/m3) measured by filtration and 2.8 × 104 CFU/m3 (SD = 2.2 × 104 CFU/m3) by impaction. Total and respirable CFU concentrations measured by impaction were significantly (p < 0.05) higher than that by filtration. The persistent strains of microorganisms were various species of the following genera: Staphylococcus, Pseudomonas, Bacillus, Listeria, Enterococcus, Nocardia, Lactobacillus, and Penicillium. It appears that filtration sampling can be used for a qualitative survey of bioaerosols in swine barns while the Andersen sampler is suitable for both quantitative and qualitative assessments. Received: 2 April 2001 / Accepted: 13 June 2001  相似文献   

9.
Increased bioaerosol loadings in downwind plumes from concentrated animal feeding operations (CAFOs) may increase the risk for allergy and infection in humans. In this study, we monitored airborne concentrations of culturable bacteria and fungi at upwind (background) and downwind sites at a 10,000 milking cow dairy over the course of a year. The average bacterial concentrations at the upwind site were 8.4 × 103 colony forming units (CFU) m−3 and increased to 9.9 × 105 CFU m−3 at the downwind edge of the cattle lots, decreasing to 6.3 × 104 CFU m−3 200 m farther downwind. At the same sites, the average fungal concentrations were 515, 945, and 1,010 CFU m−3, respectively. Significant correlations between the ambient weather conditions and airborne fungal and bacterial concentrations were identified. Sequence analysis of PCR-amplified DNA from bacterial clones and fungal isolates revealed genus and species level differences between upwind and downwind sites. Although we could not cultivate gram-negative bacteria, bacterial clones at downwind sites identified as being gram-negative matched with the following genera: Acinetobacter, Bradyrhizobium, Escherichia, Idiomarina, Methylobacterium, Ralstonia, and Novosphingobium. Fungal isolates from downwind matched with the following genera: Acremonium, Alternaria, Ascomycte, Aspergillus, Basidiomycete, Cladosporium, Davidiella, Doratomyces, Emericella, Lewia, Onygenales, Penicillium, Rhizopus, and Ulocladium. None of the bacterial and fungal sequence matches were affiliated with genera and species known to be pathogenic to humans. Overall, the data suggest that exposure to bioaerosols in the downwind environment decreases with increasing distance from the open-lot dairy.  相似文献   

10.
To accurately quantify airborne Aspergillus fumigatus (A. fumigatus) spores in rabbit houses, the real-time polymerase chain reaction (real-time PCR) and culture-based counting method (CCM) were employed to determine the airborne A. fumigatus spore concentrations. The results showed that, of the three rabbit houses (A, B, and C), the average concentrations of airborne A. fumigatus spores determined by real-time PCR were 3.0 × 103, 3.3 × 103, and 1.5 × 103 spores/m3 air, respectively, while those determined by CCM were 2.5 × 102, 2.8 × 102, and 1.1 × 102 colony-forming unit/m3 air (CFU/m3 air), respectively, i.e., the former concentration was 12–14 times higher than the latter one. Therefore, the conventional CCM underestimated the concentrations of airborne fungal spores, and it is insufficient to determine the microbial aerosol concentration and evaluate the health risk only using CCM.  相似文献   

11.
The emission of the airborne bacteria and fungi from an indoor wastewater treatment station adopting an integrated oxidation ditch with a vertical circle was investigated. Microbial samples were collected by the six-stage viable Andersen cascade impactor, and the samples were collected in triplicate in each sampling site per season. Culture-based method was applied to determine the concentrations of the airborne bacteria and fungi, while the cloning/sequencing method was used to characterize the genetic structure and community diversity of airborne bacteria. The highest concentrations of airborne bacteria (4155 ± 550 CFU/m3) and fungi (883 ± 150 CFU/m3) were obtained in June (summer). The lowest concentration of bacteria (1458 ± 434 CFU/m3) was determined in January (winter), and the lowest concentration of fungi (169 ± 40 CFU/m3) was found in March (spring), respectively. The particle size distribution analysis showed that most culturable bacteria obtained in all the sampling sites were in the particle size range of 1.1–4.7 µm. Most culturable fungi had particle sizes in the range 1.1–3.3 µm. Microbial population analysis showed that Bacillus sp., Acinetobacter sp., and Lysinibacillus were the main groups obtained in S1. Enterobacter was the dominant group in sampling site S2. Both the concentrations and particle size distribution of the bioaerosols in the enclosed space presented a seasonal and site-related variation. Concentration and richness of microorganisms in bioaerosols in June were higher than in September and January. The particle size distribution varied between the sampling sites, and proportion of large particles was higher in S2 than in S1 because of the settlement of large particles. Pathogenic species, such as Acinetobacter lwoffii, Staphylococcus saprophyticus, and Enterobacter sp., were isolated from the bioaerosols, which could pose serious latent danger to sewage workers’ health.  相似文献   

12.
The number of airborne microorganisms in the area of large-scale composting facilities with different composting techniques (A: open facility using the intensive decomposition process [4000 t/year]. B: closed facility with compost containers [7000 t/year], C: closed facility with table-pile compositing and automatic turning equipment [22 000 t/year]) was investigated using impactor sampling systems (Andersen samplers). All counts carried out inside the closed facilities, especially during the turning process, showed values of >5.0 × 105 CFU/m3 for viable bacteria and moulds with a proportion ofAspergillus fumigatus of up to 64%. Depending on the type of facility, different median values were determined inside the plant area. Counts were highest in the immediate area around the biofilter outside of Facility C (1.7 × 104 CFU/m3 for bacteria and 9.5 × 103 CFU/m3 for moulds). In view of the high load of ambient airborne microorganisms inside the composting facilities, adequate occupational health measures are urgently required. Counts determining the hazard to neighbourhood residents at distances of between 150 and 2000 m showed, depending on the facility, annual median values of 170–330 CFU/m3 for bacteria, 75–340 CFU/m3 for moulds, and 15–52 CFU/m3 forA. fumigatus. Higher individual counts — up to 3 × 103 CFU/m3 for moulds and up to 350 CFU/m3 forA. fumigatus — were found as a result of specific climatic influences, (e.g. winds) and activities as well poor operation. Given the high proportion ofA. fumigatus in the exhaust air, this mould can serve as an indicator for the evaluation of the health risk. However, the maximum values found in the present study, may also be caused by other events in rural areas, (e.g. agricultural activities). With regard to neighbourhood residents, odour complaints are more important than pollution by microorganisms.  相似文献   

13.

In recent years, monitoring of airborne bacteria and fungi concentrations has obtained increasing universal attraction not only for influences on ecological balance but also for evaluating their public health consequences. In this study, we aimed to investigate culturable airborne bacteria and fungi levels in different sites of Abadan, and their association with meteorological parameters and PM2.5 levels. Abadan is one of the most industrialized cities in the southwest of Iran where over the current decade has experienced lots of dust storm episodes. In total, 400 air samples were collected in 6 months (autumn and winter) using a single-stage viable Andersen cascade impactor for sampling airborne bacteria and fungi and portable DustTrak Aerosol Monitor 8520 for measuring PM2.5 concentrations and meteorological parameters. Microbial concentrations showed a significant difference between various sites over the study period with averages of 569.57?±?312.64 and 482.73?±?242.86 CFU/M3 for bacteria and fungi, respectively. The air temperature had a significant effect on the concentration of both airborne bacteria and fungi. A significant positive correlation between relative humidity and fungi but no correlation between relative humidity and bacteria concentrations were observed. The average airborne PM2.5 concentrations of all sites among the study period was 93.24?±?116.72 μg/m3. The atmospheric bacterial and fungal communities were strongly positively correlated with the ambient PM2.5 level. The levels of airborne bacteria and fungi along with PM2.5 in the air of the city were relatively higher than the recommended levels. Therefore, the best course of action is needed to control emission sources. Further studies are also needed to evaluate the clinical analysis of the health effects of exposure to these pollutants.

  相似文献   

14.
The project was aimed at evaluating the potential occupational exposure of swine farm workers to dust and microorganisms present in piggery bioaerosols (especially in its respirable fraction) under various breeding conditions. Sampling was carried out in 14 buildings located at 13 pig breeding and production farms in Poland. Concentrations of inhalable and respirable dusts in the air of the piggeries were low (means, respectively, 1.76 and 0.23 mg/m3). The concentration of microorganisms was generally high (mean = 3.53 × 10cfu/m3). More than 96% of determined microorganisms were bacteria (mean = 3.42 × 105 cfu/m3). The fungal concentration was distinctly lower (mean = 2.71 × 10cfu/m3). The concentration of bacteria in the respirable fraction of bioaerosol (mean = 1.51 × 10cfu/m3) made up for 48.2% of their total concentration, while the level of fungi in that fraction (mean = 1.50 × 10cfu/m3) formed 68.8% of the total fungal concentration. The concentration of inhalable dust was significantly modified by the type of breeding system. The factors that significantly affected the total concentrations of microbes and bacteria, as well as their levels in the bioaerosols’ respirable fraction were as follows: herd size, breeding system, feeding method and the type of ventilation system. In the case of fungi, these were the livestock breeding system and the feeding method. Moreover, there was a high positive correlation of inhalable dust concentrations with the fungal concentration, CO2 and relative humidity. A negative correlation was found between concentrations of each microbe group and the airflow velocity. Swine farm workers are exposed to relatively low dust concentrations and high concentrations of microorganisms, bacteria in particular. Fungi, to a much larger extent than bacteria, are correlated with the respirable particles of a piggery bioaerosol, which may harm the respiratory system of exposed workers.  相似文献   

15.
Duan  Yulong  Wu  Fasi  He  Dongpeng  Gu  Ji-Dong  Feng  Huyuan  Chen  Tuo  Liu  Guangxiu  Wang  Wanfu 《Aerobiologia》2021,37(4):681-694

The deposition of the airborne microorganisms onto cultural heritage is associated closely with the subsequent biodeterioration. In this study, a systematic investigation was carried out to detect the seasonal variation and diversity of airborne fungal concentration at the World Cultural Heritage Site Maijishan Grottoes in western China. A bio-aerosol sampler was deployed to collect samples over four seasons in 2016. The culturable airborne fungi were isolated, purified and then identified with the extraction of genomic DNA, PCR amplification of ITS rRNA region, sequencing, and phylogenetic analysis. The concentrations of culturable fungi ranged from 216 to 1389 CFU/m3, which varied seasonally with significant differences among the sampling sites. Fifteen different fungal genera were confirmed, among them, Cladosporium was the most predominant fungal genus, followed by Penicillium. The fungal community structure and their relationship with environmental factors were also delineated. The spatial–temporal differences of airborne fungi at Maijishan Grottoes were mainly due to height, rainfall, relative humidity, and temperature. The dominant genera Cladosporium and Penicillium may pose potential threats to the ancient painted sculptures and murals, and monitoring of the airborne fungi at such a heritage site could provide supporting data for the pre-warning and control of fungal outbreaks inside the caves for better management.

  相似文献   

16.
An experimental investigation was carried out to determine the agreement between two methods of viable bacteria aerosol detection. Various amounts of Bacillus globigii (BG) spores were aerosolized in 1-s bursts into a HEPA-filtered air stream and sampled simultaneously with a fluorescence aerosol particle sensor (FLAPS) and a slit to agar biological air sampler. The slit sampler incorporated 150-mm malt extract culture plates, which were incubated at 37°C for at least 12 h before culturable BG particles were counted in terms of colony-forming units (CFU). A relationship between CFU and optically detected viable bacteria particles was determined as culturable particle concentrations decreased. Through further analytical procedures, the FLAPS showed a limit of detection (LOD) of 4.2 bacterial particle/2.5 l of sampled air or 1.7 × 103 m−3. This real-time bacteria aerosol monitor could be used to detect burst contamination events during a surgical procedure. The technology may be used for developing a dose–response relationship between bacterial particle exposure and infection, a tool potentially helpful in determining patient risk.  相似文献   

17.
This study aimed to remove complex odorous gas produced from composting using a biotrickling filter and to observe the temporal and special distributions of bacteria, fungi, and actinomycetes. The removal efficiencies of the total volatile organic compounds (TVOC) were 26.1% and 81.5% before and after inoculation of volatile organic compounds (VOC)-degrading microbes, respectively. Especially trimethylamine was 100% degraded. In the first and second composting period, the odor reduction efficiencies showed average values of 86.2% and 94.5%, respectively. The total average of the bacteria in the biofilm was 2.06 × 109 CFU/g TS, which was 22.2% higher than that of the control (the culture of microbes prior to the inoculation of VOC-degrading microbes). The bacteria may have played a predominant role in odor removal. The total average of the fungi in the biofilm was 9.64 × 106 CFU/g TS, which was only 6.40% of the control. The total average of the actinomycetes in the biofilm was 5.10 × 105 CFU/g TS, which was 5.63 times higher than that of the control. Findings from this study showed that usage of a biotrickling filter is a promising process for the treatment of complex odorous gas.  相似文献   

18.
Culturable Airborne Bacteria in Outdoor Environments in Beijing,China   总被引:5,自引:0,他引:5  
Fang Z  Ouyang Z  Zheng H  Wang X  Hu L 《Microbial ecology》2007,54(3):487-496
Airborne bacteria are important biological components of bioaerosol and play an important role in ecosystem. Bacteria at a high concentration in the atmosphere can result in biological air pollution and all kinds of diseases. In this study, a systematical survey on the culturable airborne bacteria was carried out for 1 year at three sites in Beijing urban area. Results showed that concentrations of culturable bacteria ranged from 71 colony forming units (CFU)/m3 to 22,100 CFU/m3, and the mean was 2,217 CFU/m3. Bacterial concentrations at the human activity-enriched site (RCEES) and the highly trafficked site (XZM) were virtually the same point. They were significantly higher than those at the greener site (BBG). Significant variation in bacterial concentrations in different seasons was observed at RCEES and XZM with higher concentrations in summer and autumn. In a single day, significantly lower concentrations were detected at 13:00 hours through all sampling sites. In this study, 165 species in 47 genera of culturable bacteria were identified. Micrococcus was one of the most dominant bacterial groups and contributed to approximately 20∼30% of the total bacterial concentration, followed by Staphylococcus, Bacillus, Corynebacterium, and Pseudomonas. The bacterial species with a high concentration percentage included Micrococcus luteus and Micrococcus roseus.  相似文献   

19.
Many working environments are predisposed for larger than average amounts of fungi and other microorganisms often due to organic material being handled. From 2003 to 2007, the area used for strawberry production in Denmark increased by 62%. The purpose of this study was to determine the levels of exposure to microorganisms, endotoxin, (1→3)-β-d-glucan (β-glucan), and pollen in a field of strawberries. The study was carried out in eastern Denmark from the middle of June to the beginning of August 2008. The strawberries were grown organically, and microbiological pest control agents (MPCAs) were applied during this and former growth seasons. In order to measure exposure to inhalable bioaerosol components, we used stationary filter samplers. Bioaerosol sampling was performed during 4 working days, and a total of 57 samplings were performed. The filters were analysed for contents of fungi, MPCAs, endotoxin, β-glucan, and pollen. The mean exposure was 6,154 CFU Cladosporium sp. m−3, 1.0 × 105 fungal spores m−3, 4.1 × 104 hyphal fragments m−3, 5.8 × 103 pollen m−3, 57.3 ng β-glucan m−3, and 8.9 endotoxin units (EU) m−3. A significant and positive correlation was found between β-glucan and fungal spores and between CFU of Cladosporium sp. and CFU of fungi. We selected specifically for Metarhizium anisopliae, Beauveria bassiana, and the applied MPCAs Trichoderma harzianum, T. polysporum, and Bacillus thuringiensis but found none of these species. In conclusion, our study shows that berry pickers in this organic strawberry field were potentially subjected to higher levels of fungal spores, Cladosporium sp., hyphal fragments, pollen, and thus also β-glucan than is usually seen in outdoor air. Exposure to MPCAs was not seen. The exposure to endotoxin was only slightly higher than e.g. in a town.  相似文献   

20.
In 12 selected flats in Sosnowiec, Upper Silesia, the concentrations of particulate aerosol, bioaerosol and bacterial endotoxin were examined. Concentrations of particulate aerosol, bacteria, fungi and endotoxin were in the order of 101–102 μg/m3, 101–103 cfu/m3, 100–102 cfu/m3 and 10−2–10−1 ng/m3, respectively. The most numerous group of microorganisms in indoor air during the winter season were Gram positive mesophilic bacteria. They were more common in flats polluted with tobacco smoke. The concentrations of airborne endotoxins were higher in flats polluted with tobacco smoke in all size ranges. The highest level of endotoxins was found in the fraction of fine particles below 5μm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号