首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Twelve compounds representing procarbazine, seven metabolites, and an internal standard were analyzed by gas chromatography—mass spectrometry on a 3% OV-1 column. Procarbazine and four metabolites were derivatized with acetic anhydride.A sensitive, specific and quantitative assay was established by selected ion monitoring using a synthetic analogue of the drug as an internal standard. The limits of detection were approximately 1 ng/ml of plasma while the limits of quantitation were 10 ng/ml of plasma.Studies on the degradation of procarbazine - HCl in 0.05 M phosphate buffer (pH 7.4) were compared to in vivo studies. At 1 h after incubation of procarbazine - HCl in buffer, the azo and aldehyde metabolites were detected in the highest concentrations representing 27.2% and 20.3% of total drug and metabolites. In the in vivo studies, analyses of rat plasmas indicated that 1 h after an oral dose of procarbazine - HCl, the aldehyde metabolite represented 72% of the total drug and metabolites, and that relatively little of the azo metabolite was present.  相似文献   

2.
3.
A sensitive gas chromatographic method for the determination of cyclophosphamide in urine is presented. After liquid—liquid extraction with diethyl ether and derivatization with trifluoroacetic anhydride, cyclophosphamide was identified and quantified with mass spectrometry. The method is suitable for the determination of cyclophosphamide at concentrations of more than 0.25 ng/ml, which enables the uptake of cyclophosphamide during occupational activities, such as the preparation and administration of antineoplastic agents in hospitals, to be measured. Simple preparation makes the method appropriate for routine analysis.  相似文献   

4.
A reversed-phase high-performance liquid chromatographic method is described for the determination of 3-methylhistidine content in human urine using pre-column derivatization with phenylisothiocyanate, isocratic elution with 15 mM sodium acetate—acetonitrile (92:8, v/v) and electrochemical detection. The limit of quantitation was 0.1 pmol. The method has been applied in routine analyses of 3-methylhistidine in both clinical and research work.  相似文献   

5.
A gas chromatographic—mass spectrometric assay, using selected-ion monitoring (GC-MS-SIM) with thymol as internal standard, was developed for quantitating propofol, an intravenous anaesthetic. The method described is rapid and sensitive for the determination of propofol in whole blood. The sensitivity of the present method is 10 ng/ml. The recovery of propofol added to human whole blood in the concentration range 10-10 000 ng/ml ranged between 95 and 100%. A single extraction procedure was used with chloroform-ethyl acetate. The assay allowed the detection of two metabolites formed during propofol metabolism: 2,6-diisopropyl-1,4-quinone and 2,6-diisopropyl-1,4-quinol.  相似文献   

6.
A gas chromatographic—mass spectrometric method was developed to determine eperisone hydrochloride, 4′-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2–40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml, the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.  相似文献   

7.
A simple, sensitive method for measuring Nτ-methylhistidine in biological samples using a deuterated internal standard and methane chemical ionization gas chromatography-mass spectrometry is described. After sample preparation, a single analysis can be completed in 3 min; analysis in duplicate, including sample preparation for 40 samples, can be completed at a rate of 15 min per sample. Nanomole amounts of Nτ-mmethylhistidine in urine or plasma samples are determined with a precision of 0.5%. Picomole amounts, released during in vitro rat epitrochlaris muscle incubations, are measured with a precision of 10%.  相似文献   

8.
9.
The simultaneous assay of cocaine, opiates and metabolites in small biological samples continues to be a difficult task. This report focuses upon tabulation of important techniques (extraction, derivatization, chromatographic conditions, detection mode, data acquisition) reported over the last decade that were used in the development of assays for these analytes. The most prevalent procedures for extraction of cocaine, opiates and metabolites were liquid—liquid and solid-phase extraction isolation methods. Following extraction analytes were derivatized and analyzed by gas chromatography—mass spectrometry. The technique most often used for chromatographic separation was fused-silica capillary column gas chromatography. Detection generally was performed by selected ion monitoring in the positive-ion electron-impact ionization mode, although full-scan acquisition and positive- and negative-ion chemical ionization methods have been used. It was apparent from the review that there is a continuing need for greater sensitivity and selectivity in the assay of highly potent opiates and for cocaine and metabolites.  相似文献   

10.
The analysis of methadone and its metabolites in biological fluids by gas chromatography—mass spectrometry is described with deuterated methadone and metabolites as internal standards. The method allowed the determination of 20 ng methadone in 0.5 ml of plasma or saliva. Mean saliva to plasma ratio of methadone for two patients was determined to be 0.51 ± 0.13. Methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) in urine were measured by selected ion monitoring. Gas chromatography—mass spectrometry was found to have advantages over conventional gas chromatographic methods in terms of ratio analysis. 1,5-Dimethyl-3,3-diphenyl-2-pyrrolidone previously reported as a metabolite was shown to result primarily from the decomposition of EDDP free base.  相似文献   

11.
Human urinary metabolites of the synthetic corticosteroids prednisone and prednisolone were detected in the course of gas chromatographic steroid profiling as methoxime-trimethylsilyl derivatives. Metabolites were provisionaly identified by combined gas chromatography—mass spectrometry. The major metabolites were 11-keto/11-hydroxy conversion products, 20-hydroxy and 4,5-dihydro analogues of the parent drugs. Cortisone, 6-hydroxy and fully saturated A-ring compounds were minor metabolites. Retention indices and mass spectral data are presented.  相似文献   

12.
A method for the simultaneous analysis of phenolic amines and aliphatic amines in human urine is described. The amine metabolites in urine were extracted using Dowex 50W-X8 cationic resin, derivatized and analyzed by a gas chromatographic—mass spectrometric—computer system. The amine metabolites profile of 5 ml of urine was obtained with good gas chromatographic separation. The gas chromatographic method described here separates urinary phenolic amines, di- and polyamines and methylguanidine in a single chromatographic separation. The urinary levels of methylguanidine, putrescine, cadaverine, spermidine, p-tyramine, dopamine, and 3-methoxytyramine were quantitated by using a mass spectrometric technique. In uremic patients, only the urinary excretion of methylguanidine was increased in comparison with normal subjects, although the urinary excretion of other amines was decreased in uremic patients.  相似文献   

13.
A method was developed for the routine screening, confirmation and quantitation of corticosteroids in human urine using bench top capillary gas chromatography (GC)—mass-selective detection. The free and conjugated corticosteroid fractions were isolated by liquid—liquid partition. After evaporation to dryness under vacuum the corticosteroid residues were derivatized to form the methyloxime trimethylsilyl ether derivatives. Both GC retention data and characteristic spectral data based on authentic reference standards were used for the identification and quantitation of cortisol, cortisone, tetrahydrocortisol and tetrahydrocortisone in the ppb (ng/ml) concentration range. The method is simpler and more efficient than the other GC—mass spectrometric (MS) techniques. It is also more sensitive than the liquid chromatographic—MS method.  相似文献   

14.
A specific, sensitive and accurate quantitation method for glyceryl trinitrate was developed using gas chromatography—negative ion chemical ionization—selected ion monitoring with dichloromethane as a reagent gas. [15N3] and [2H5, 15N3] variants were synthesized from non-labelled or [2H8]glycerol and [15N]nitric acid. The former variant was used for preventing adsorption of glyceryl trinitrate onto active sites on column materials and the latter was used as an internal standard for quantitation of glyceryl trinitrate in biological fluids by selected ion monitoring. The quantitation limit of this method is 0.1 ng/ml of human plasma. When glyceryl trinitrate was administered intravenously in the dose of 4 μg/kg to patients receiving hypotensive anesthesia for surgical operation, the plasma levels exhibited a biexponential decay. The mean and standard deviation of half-lives of the α and β phases were found to be about 0.41 ± 0.13 and 5.34 ± 1.60 min, respectively.  相似文献   

15.
A highly specific method for the determination of the plasma level of the potent vasodilator 2-(N-benzyl-N-methylamino)ethyl methyl 2,6-dimethyl-4-(m-nitrophenyl)-1,4-dihydropyridine carboxylate hydrochloride (nicardipine hydrochloride) in rats, dogs and humans is described. N-d3-Methyl derivative was added as an internal standard, then the plasma was extracted with diethyl ether and subjected to thin-layer chromatography (TLC) to remove the pyridine analogue, one of the drug's metabolites. The area corresponding to the unchanged drug was identified with simultaneously run N-d7-benzyl derivative under UV light. The unchanged drug with a 1,4-dihydropyridine structure was oxidized with nitrous acid to its pyridine analogue, which was stable for gas chromatography, and subjected to mass spectrometry at m/e 134 (nicardipine) and m/e 137 (N-d3-methyl derivative). The sensitivity limit was 5 ng ml−1. The ratio of the unchanged drug to the value obtained by the method without TLC separation was 100% for rats and 80% for dogs and humans at almost all times investigated after dosing. These results demonstrate that in these species, the amount of pyridine analogue in plasma was very small compared with that of the parent drug.  相似文献   

16.
17.
A thermospray ion source using corona discharge ionization was interfaced to a quadrupole ion trap mass spectrometer via a multi-element lens system. Ions were injected into the trap periodically where they were stabilized by collisions with helium bath gas. Mass spectra were recorded on the trapped ions using the mass-selective instability scan mode. Data are shown for a peptide and a nucleoside and the effects of some experimental variables on the spectra are explored.  相似文献   

18.
19.
A method is described for the determination of the neutral metabolites formed from catecholamines and various other structurally related phenylethylamines by using gas chromatography—chemical ionization—mass spectrometry. These metabolites (phenylglycols and phenylethanols) were extracted from urine specimens and converted to pentafluoropropionyl derivatives which were separated on either 3% OV-1, 3% SP-2250, or 3% QF-1 packed columns. Our results demonstrate the presence in human urine of p-hydroxyphenylglycol, a metabolite of octopamine. One patient excreted 13 and 91 μg/day of free and total (free + conjugated) p-hydroxyphenylglycol, respectively. Treatment with a monoamine oxidase inhibitor reduced the excretion of total p-hydroxyphenylglycol to 30% of baseline level.  相似文献   

20.
A specific and sensitive method for the determination of several β-agonistic drugs in liver and urine is described. Following clean-up by immunoaffinity chromatography and two different derivatizations, gas chromatography—mass spectrometry with electron-impact ionization is performed. The immunoaffinity chromatography columns were packed with Sepharose-immobilized polyclonal antibodies raised against the β-agonist clenbuterol. Owing to the high clean-up efficiency of the immunoaffinity column large sample volumes can be used (up to 100 ml urine or 25 gram liver). The immunoaffinity sample pretreatment is highly specific and no further sample pretreatment was necessary. Due to the combination of two different derivatizations only GC—MS with electron-impact ionization is necessary to fulfil legal requirements. The first confirmation step consists of a derivatization reaction between the hydroxyl group of the parent compound and trimethylsilane. The second confirmation method is a derivatization to a cyclic derivative with the hydroxyl group and the aliphatic nitrogen group. Limits of determination in liver as well in urine are at the 10 ng/kg or ng/l (ppt) level with acceptable signal-to-noise ratio. The method is suitable for identification and quantification of trace amounts of several similar β-agonistic drugs either used separately or in combination and can be used also for quantification of clenbuterol in liver with regard to levels exceeding the maximum residue limit (MRL) of 1 μg/kg (ppb).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号